Owner’s Manual
Permanently Lubricated
Single Stage
Side Stack
AIR COMPRESSOR
Model No.
919.724580
• Safety Guidelines
• Assembly
• Operation
• Maintenance
• Service and Adjustments
• Troubleshooting
• Repair Parts
CAUTION: Read the Safety Guidelines
and All Instructions Carefully Before
Operating.
Sold by Sears Canada, Inc. Toronto, Ont. M5B 2B8
D24456 Rev. 3 10/21/02
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATION CHART
Model No.
Max. Developed HP
Bore
919-724580
3
2.375"
1.35"
120
15 amps
Time Delay
4
120
150
7.9
Stroke
Voltage-Single Phase
Minimum Branch Circuit Requirement
Fuse Type
Air Tank Capacity - Gallons
Approximate Cut-in Pressure
Approximate Cut-out Pressure
SCFM@ 40 psig
SCFM@ 90 psig
5.5
SAFETY GUIDELINES - DEFINITIONS
This manual contains information that is important for you to know and understand. This information
relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you
recognize this information, we use the symbols below. Please read the manual and pay attention to
these sections.
Indicates an
imminently hazardous
Indicates a potentially
hazardous situation
situation which, if not avoided, will
result in death or serious injury.
which, if not avoided, may result in
minor or moderate injury.
Used without the
safety alert symbol
Indicates a potentially
hazardous situation
indicates a potentially hazardous
situation which, if not avoided, may
result in property damage.
which, if not avoided, could result in
death or serious injury.
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN
SERIOUS INJURY AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL
WARNINGS AND OPERATING INSTRUCTIONS BEFORE USING THIS EQUIPMENT.
Some dust created by power sanding, sawing, grinding, drilling, and other
construction activities contains chemicals known (to the State of California) to
cause cancer, birth defects or other reproductive harm. Some example of these chemicals are:
G
lead from lead-based paints
G
crystalline silica from bricks and cement and other masonry products
G
arsenic and chromium from chemically-treated lumber
Your risk from these exposures varies, depending on how often you do this type of work. To reduce
your exposure to these chemicals: work in a well ventilated area, and work with approved safety
equipment, always wear MSHA/NIOSH approved, properly fitting face mask or respirator when using
such tools.
When using air tools, basic safety precautions should always be followed to reduce the risk of of
personal injury.
3- ENG
D24456
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
Save these instructions
Improper operation or maintenance of this product could result in serious injury and
property damage. Read and understand all warnings and operation instructions before
using this equipment.
HAZARD
WARNING: Risk of explosion or fire
What Could Happen
How To Prevent It
Always operate the compressor in a well
ventilated area free of combustible
materials, gasoline, or solvent vapors.
It is normal for electrical contacts within
the motor and pressure switch to spark.
If spraying flammable materials, locate
compressor at least 20 feet away from
spray area. An additional length of hose
may be required.
If electrical sparks from compressor
come into contact with flammable
vapors, they may ignite, causing fire or
explosion.
Store flammable materials in a secure
location away from compressor.
Never place objects against or on top
of compressor. Operate compressor in
an open area at least 12 inches away
from any wall or obstruction that would
restrict the flow of fresh air to the
ventilation openings.
Restricting any of the compressor
ventilation openings will cause serious
overheating and could cause fire.
Operate compressor in a clean, dry well
ventilated area. Do not operate unit
indoors or in any confined area.
Always remain in attendance with the
Unattended operation of this product
could result in personal injury or
property damage. To reduce the risk of
fire, do not allow the compressor to
operate unattended.
product when it is operating.
Always disconnect electrical power by
moving pressure switch lever to the off
position and drain tank daily or after
each use.
4- ENG
D24456
Download from Www.Somanuals.com. All Manuals Search And Download.
HAZARD
WARNING: Risk of Bursting
Air Tank: The following conditions could lead to a weakening of the tank, and result
in a violent tank explosion and could cause property damage or serious injury.
What Could Happen
1. Failure to properly drain
condensed water from tank,
causing rust and thinning of the
steel tank.
How To Prevent It
Drain tank daily or after each use. If
tank develops a leak, replace it
immediately with a new tank or replace
the entire compressor.
2. Modifications or attempted repairs
to the tank.
Never drill into, weld, or make any
modifications to the tank or its
attachments.
3. Unauthorized modifications to the
unloader valve, safety valve, or any
other components which control
tank pressure.
The tank is designed to withstand specific
operating pressures. Never make
adjustments or parts substitutions to
alter the factory set operating
pressures.
4. Excessive vibration can weaken
the air tank and cause rupture or
explosion
For essential control of air pressure, you
must install a pressure regulator and
pressure gauge to the air outlet (if not
equipped) of your compressor. Follow the
equipment manufacturers
recommendation and never exceed the
maximum allowable pressure rating of
attachments. Never use compressor to
inflate small low pressure objects such
as children’s toys, footballs,
ATTACHMENTS & ACCESSORIES:
Exceeding the pressure rating of air
tools, spray guns, air operated
accessories, tires, and other inflatables
can cause them to explode or fly apart,
and could result in serious injury.
basketballs, etc.
HAZARD
WARNING: Risk from Flying Objects
WHAT CAN HAPPEN
HOW TO PREVENT IT
Always wear ANSI Z87.1 approved safety
glasses with side shields when using the
compressor.
The compressed air stream can cause
soft tissue damage to exposed skin and
can propel dirt, chips, loose particles,
and small objects at high speed,
resulting in property damage or personal
injury.
Never point any nozzle or sprayer
toward any part of the body or at other
people or animals.
Always turn the compressor off and
bleed pressure from the air hose and tank
before attempting maintenance, attaching
tools or accessories.
5- ENG
D24456
Download from Www.Somanuals.com. All Manuals Search And Download.
HAZARD
WARNING: Risk of Electrical Shock
WHAT CAN HAPPEN
HOW TO PREVENT IT
Your air compressor is powered by
electricity. Like any other electrically
powered device, If it is not used properly
it may cause electric shock.
Never operate the compressor outdoors
when it is raining or in wet conditions.
Never operate compressor with
protective covers removed or damaged.
Repairs attempted by unqualified
personnel can result in serious injury or
death by electrocution.
Any electrical wiring or repairs required
on this product should be performed by
authorized service center personnel in
accordance with national and local
electrical codes.
Electrical Grounding: Failure to provide
adequate grounding to this product
could result in serious injury or death
from electrocution. See grounding
instructions.
Make certain that the electrical circuit
to which the compressor is connected
provides proper electrical grounding,
correct voltage and adequate fuse
protection.
HAZARD
WARNING: Risk to Breathing
WHAT CAN HAPPEN
HOW TO PREVENT IT
Air obtained directly from the compressor
should never be used to supply air for
human consumption. In order to use air
produced by this compressor for
breathing, suitable filters and in-line
safety equipment must be properly
installed. In-line filters and safety
The compressed air directly from your
compressor is not safe for breathing.
The air stream may contain carbon
monoxide, toxic vapors, or solid
particles from the tank. Breathing these
contaminants can cause serious injury
or death.
equipment used in conjunction with the
compressor must be capable of treating
air to all applicable local and federal
codes prior to human consumption.
Work in an area with good cross
ventilation. Read and follow the safety
instructions provided on the label or
safety data sheets for the materials you
are spraying. Use a NIOSH/ MSHA
approved respirator designed for use
with your specific application.
Sprayed materials such as paint, paint
solvents, paint remover, insecticides,
weed killers, may contain harmful vapors
and poisons.
6- ENG
D24456
Download from Www.Somanuals.com. All Manuals Search And Download.
HAZARD
WARNING: Risk of Burns
WHAT CAN HAPPEN
HOW TO PREVENT IT
Touching exposed metal such as the
compressor head or outlet tubes, can
result in serious burns.
Never touch any exposed metal parts
on compressor during or immediately
after operation. Compressor will remain
hot for several minutes after operation.
Do not reach around protective shrouds
or attempt maintenance until unit has
been allowed to cool.
HAZARD
WARNING: Risk from Moving Parts
WHAT CAN HAPPEN
HOW TO PREVENT IT
Moving parts such as the pulley, flywheel,
and belt can cause serious injury if they
come into contact with you or your
clothing.
Never operate the compressor with
guards or covers which are damaged or
removed.
Any repairs required on this product
should be performed by authorized
service center personnel.
Attempting to operate compressor with
damaged or missing parts or attempting
to repair compressor with protective
shrouds removed can expose you to
moving parts and can result in serious
injury.
HAZARD
Risk of Falling
WHAT CAN HAPPEN
HOW TO PREVENT IT
ALWAYS OPERATE COMPRESSOR IN A
STABLE SECURE POSITION TO PREVENT
ACCIDENTAL MOVEMENT OF THE UNIT.
NEVER OPERATE COMPRESSOR ON A ROOF
OR OTHER ELEVATED POSITION. USE
ADDITIONAL AIR HOSE TO REACH HIGH
LOCATIONS.
A PORTABLE COMPRESSOR CAN FALL
FROM A TABLE, WORKBENCH OR ROOF
CAUSING DAMAGE TO THE COMPRESSOR
AND COULD RESULT IN SERIOUS INJURY
OR DEATH TO THE OPERATOR.
7- ENG
Download from Www.Somanuals.com. All Manuals Search And Download.
D24456
HAZARD
WARNING: Risk or Serious Injury or Property Damage
When Transporting Compressor
(Fire, Inhalation, Damage to Vehicle Surfaces)
WHAT CAN HAPPEN
HOW TO PREVENT IT
Always place compressor on a
protective mat when transporting to
protect against damage to vehicle from
leaks. Remove compressor from vehicle
immediately upon arrival at your
destination.
Oil can leak or spill and could result in
fire or breathing hazard; serious injury or
death can result. Oil leaks will damage
carpet, paint or other surfaces in vehicles
or trailers.
HAZARD
WARNING: Risk Unsafe Operation
WHAT CAN HAPPEN
HOW TO PREVENT IT
Unsafe operation of your air compressor
could lead to serious injury or death to
you or others.
Review and understand all instructions
and warnings in this manual.
Become familiar with the operation and
controls of the air compressor.
Keep operating area clear of all persons,
pets, and obstacles.
Keep children away from the air
compressor at all times.
Do not operate the product when
fatigued or under the influence of
alcohol or drugs. Stay alert at all times.
Never defeat the safety features of this
product.
Equip area of operation with a fire
extinguisher.
Do not operate machine with missing,
broken, or unauthorized parts.
8- ENG
Download from Www.Somanuals.com. All Manuals Search And Download.
D24456
GLOSSARY
When the tank pressure drops to a
Become familiar with these terms
before operating the unit.
CFM: Cubic feet per minute.
SCFM: Standard cubic feet per
minute; a unit of measure of air
delivery.
certain low level the motor will restart
automatically. The low pressure at
which the motor automatically
restarts is called "cut-in" pressure.
Cut-Out Pressure: When an air
compressor is turned on and begins
to run, air pressure in the air tank
begins to build. It builds to a certain
high pressure before the motor
automatically shuts off - protecting
your air tank from pressure higher
than its capacity. The high pressure
at which the motor shuts off is called
"cut-out" pressure.
PSIG: Pounds per square inch
gauge; a unit of measure of pressure.
Code Certification: Products that
bear one or more of the following
marks: UL, CUL, ETL, CETL, have
been evaluated by OSHA certified
independent safety laboratories and
meet the applicable Underwriters
Laboratories Standards for Safety.
Cut-In Pressure: While the motor is
off, air tank pressure drops as you
continue to use your accessory.
Branch Circuit: Circuit carrying
electricity from electrical panel to
outlet.
ACCESSORIES
This unit is capable of powering the following Accessories. The accessories are
available through the current Power and Hand Tool Catalog or full-line Sears
stores.
Accessories
•
•
Oil Fog Lubricators
Air Hose:1/4", 3/8" or 1/2" I.D. in
various lengths
•
•
•
In Line Filter
Tire Air Chuck
Quick Connector Sets (various
sizes)
Refer to the selection chart located
on the unit to select the tools this unit
is capable of powering.
•
Air Pressure Regulators
DUTY CYCLE
the air compressor is undersized for
the required air demand. Maximum
compressor pumping time per hour is
30 minutes.
Air compressors should be operated
on not more than a 50% duty cycle.
This means an air compressor that
pumps air more than 50% of one
hour is considered misuse, because
9- ENG
Download from Www.Somanuals.com. All Manuals Search And Download.
D24456
ASSEMBLY
Unpacking
1. Remove unit from carton and
discard all packaging.
INSTALLATION
IMPORTANT: The outlet being used
must be installed and grounded in
accordance with all local codes and
ordinances.
HOW TO SET UP YOUR
UNIT
Location of the Air Compressor
Locate the air compressor in a clean,
dry and well ventilated area. The air
compressor should be located at
least 12" away from the wall or other
obstructions that will interfere with
the flow of air. The air compressor
pump and shroud are designed to
allow for proper cooling. The
ventilation openings on the
2. Make sure the outlet being used
has the same configuration as
the grounded plug. DO NOT
USE AN ADAPTER. See
illustration.
Plug
Grounded
Outlets
compressor are necessary to
maintain proper operating
temperature. Do not place rags or
other containers on or near these
openings.
Grounding Pin
3. Inspect the plug and cord before
each use. Do not use if there are
signs of damage.
GROUNDING INSTRUCTIONS
RISK OF
ELECTRICAL
4. If these grounding instructions
are not completely understood,
or if in doubt as to whether the
compressor is properly
SHOCK. In the event of a short
circuit, grounding reduces the risk
of shock by providing an escape
wire for the electric current. This
air compressor must be properly
grounded.
grounded, have the installation
checked by a qualified
electrician.
IMPROPER
GROUNDING CAN
The portable air compressor is
equipped with a cord having a
grounding wire with an appropriate
grounding plug (see following
illustrations). The plug must be used
with an outlet that has been installed
and grounded in accordance with all
local codes and ordinances.
RESULT IN ELECTRICAL SHOCK.
Do not modify the plug provided. If
it does not fit the available outlet, a
correct outlet should be installed
by a qualified electrician.
Repairs to the cord set or plug
MUST be made by a qualified
electrician.
1. The cord set and plug with this
unit contains a grounding pin.
This plug MUST be used with a
grounded outlet.
10- ENG
D24456
Download from Www.Somanuals.com. All Manuals Search And Download.
Extension Cords
Voltage and Circuit Protection
Use extra air hose instead of an
extension cord to avoid voltage drop
and power loss to the motor, and to
prevent overheating.
Refer to the Parts Manual for the
voltage and minimum branch circuit
requirements.
Certain air compressors can be
operated on a 15 amp circuit if the
following conditions are met.
If an extension cord must be used,
be sure it is:
•
a 3-wire extension cord that has
a 3-blade grounding plug, and a
3-slot receptacle that will accept
the plug on the product
1. Voltage supply through branch
circuit is 15 amps.
2. Circuit is not used to supply any
other electrical needs (lights,
appliances, etc.).
•
•
•
in good condition
no longer than 50 feet
3. Extension cords comply with
specifications.
12 gauge (AWG) or larger. (Wire
size increases as gauge number
decreases. 10 AWG and 8 AWG
may also be used. DO NOT USE
14 OR 16 AWG.)
4. Circuit is equipped with a 15
amp circuit breaker or 15 amp
time delay fuse. NOTE: If
compressor is connected to a
circuit protected by fuses, use
only time delay fuses. Time delay
fuses should be marked "D" in
Canada and "T" in the US.
If any of the above conditions cannot
be met, or if operation of the
compressor repeatedly causes
interruption of the power, it may be
necessary to operate it from a 20
amp circuit. It is not necessary to
change the cord set.
11- ENG
D24456
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION
Know Your Air Compressor
READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING
YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with
the location of various controls and adjustments. Save this manual for future
reference.
Tank
Pressure
Gauge
Pressure
Switch
Air
Compressor
Pump
On/Auto/
Off
Switch
Outlet
Pressure
Gauge
Universal
Quick
Connect
Bodies
Regulator
Description of Operation
Become familiar with these controls
before operating the unit.
of the regulator. This pressure is
controlled by the regulator and is
always less than or equal to the tank
pressure.
On/Auto/Off Switch: Turn this switch
ON to provide automatic power to the
pressure switch and OFF to remove
power at the end of each use.
Tank Pressure Gauge: The tank
pressure gauge indicates the reserve
air pressure in the tank.
Regulator: Controls the air pressure
shown on the outlet pressure gauge.
Pull the knob out and turn clockwise
to increase pressure and
counterclockwise to decrease
pressure. When the desired pressure
is reached push knob in to lock in
place.
Pressure Switch: The pressure
switch automatically starts the motor
when the air tank pressure drops
below the factory set "cut-in"
pressure. It stops the motor when the
air tank pressure reaches the factory
set "cut-out" pressure.
Safety Valve (not shown): If the
pressure switch does not shut off the
air compressor at its "cut-out"
pressure setting, the safety valve will
protect against high pressure by
"popping out" at its factory set
pressure (slightly higher than the
pressure switch "cut-out" setting).
Universal Quick-Connect Body:
The universal quick-connect body
accepts the three most popular styles
of quick-connect plugs- Industrial,
automotive (Tru-flate), and ARO. One
hand push-to-connect operation
makes connections simple and easy.
The two quick connect bodies allow
the use of two tools at the same time.
Outlet Pressure Gauge: The outlet
pressure gauge indicates the air
pressure available at the outlet side
12- ENG
D24456
Download from Www.Somanuals.com. All Manuals Search And Download.
Cooling System (not shown): This
compressor contains an advanced
design cooling system. At the heart of
this cooling system is an engineered
fan. It is perfectly normal for this fan
to blow air through the vent holes in
large amounts. You know that the
cooling system is working when air is
being expelled.
Pressure
Release
Valve
Air Compressor Pump:
Compresses air into the air tank.
Working air is not available until the
compressor has raised the air tank
pressure above that required at the
air outlet.
How to Use Your Unit
How to Stop:
1. Set the On/Auto/Off lever to
"OFF".
Drain Valve: The drain valve is
located at the base of the air tank
and is used to drain condensation at
the end of each use.
Before Starting
Break-in instructions
Serious damage
may result if the
following break-in instructions
are not closely followed.
Check
Valve
This procedure is required before the
air compressor is put into service and
when the check valve or a complete
compressor pump has been
replaced.
Drain
Valve
Check Valve: When the air
1. Make sure the On/Auto/Off lever
is in the "OFF" position.
compressor is operating, the check
valve is "open", allowing compressed
air to enter the air tank. When the air
compressor reaches "cut-out"
pressure, the check valve "closes",
allowing air pressure to remain inside
the air tank.
NOTE: If quick connect is installed,
pull coupler back until it clicks to
prevent air from escaping through the
quick connect.
2. Plug the power cord into the
correct branch circuit receptacle.
(Refer to Voltage and Circuit
Protection paragraph in the
Installation section of this
manual.)
Pressure Release Valve: The
pressure release valve located on the
side of the pressure switch, is
designed to automatically release
compressed air from the compressor
head and the outlet tube when the air
compressor reaches "cut-out"
pressure or is shut off. The pressure
release valve allows the motor to
restart freely. When the motor stops
running, air will be heard escaping
from this valve for a few seconds. No
air should be heard leaking when the
motor is running, or continuous
leaking after unit reaches "cut-out"
pressure.
3. Open the drain valve fully
(counter-clockwise) to permit air
to escape and prevent air
pressure build up in the air tank
during the break-in period.
4. Move the On/Auto/Off lever to
"ON/AUTO" position. The
compressor will start.
13- ENG
D24456
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Run the compressor for 15
minutes. Make sure the drain
valve is open and there is
minimal air pressure build-up in
tank.
Too much air
pressure causes a
hazardous risk of bursting. Check
the manufacturer’s maximum
pressure rating for air tools and
accessories. The regulator outlet
pressure must never exceed the
maximum pressure rating.
6. After 15 minutes, close the drain
valve (clockwise). The air receiver
will fill to "cut-out" pressure and
the motor will stop.
How to Start:
1. Turn the On/Auto/Off lever to
"AUTO" and allow tank pressure
to build. Motor will stop when
tank pressure reaches "cut-out"
pressure.
The compressor is now ready for use.
Before Each Start-Up:
1. Place On/Auto/Off lever to
"OFF".
2. Pull the regulator knob out and
turn clockwise to increase
pressure. When the desired
pressure is reached push knob in
to lock in place. The compressor
is ready for use.
2. Pull regulator knob out, turn
counter-clockwise until it stops.
Push knob in to lock in place.
3. Attach hose and accessories.
NOTE: The hose or accessory
will require a quick connect plug
if the air outlet is equipped with a
quick connect.
NOTE: Always operate the air
compressor in well-ventilated areas
free of gasoline or other combustible
vapors. If the compressor is being
used to operate a sprayer DO NOT
place near the spray area.
14- ENG
D24456
Download from Www.Somanuals.com. All Manuals Search And Download.
MAINTENANCE
Customer Responsibilities
Daily or
after
each
use
Before
each
use
Yearly
Frequently
Check Safety Valve
ꢀ
ꢀ
Drain Tank
Air Filter
ꢀ (1)
Air compressor pump intake
and exhaust valves
ꢀ
1- more frequent in dusty or humid conditions
Unit cycles
To Check Safety Valve
automatically when
If the safety valve
power is on. When performing
does not work
properly, over-pressurization may
occur, causing air tank rupture or
an explosion.
maintenance, you may be exposed
to voltage sources, compressed
air, or moving parts. Personal
injuries can occur. Before
1. Before starting compressor, pull
the ring on the safety valve to
make sure that the safety valve
operates freely. If the valve is
stuck or does not operate
performing any maintenance or
repair, disconnect power source
from the compressor and bleed off
all air pressure.
smoothly, it must be replaced
with the same type of valve.
To Drain Tank
1. Set the On/Auto/Off lever to
"OFF".
To ensure efficient operation and
longer life of the air compressor unit,
a routine maintenance schedule
should be prepared and followed.
The following routine maintenance
schedule is geared to an unit in a
normal working environment
2. Pull the regulator knob out and
turn counterclockwise to set the
outlet pressure to zero.
operating on a daily basis. If
necessary, the schedule should be
modified to suit the conditions under
which your compressor is used. The
modifications will depend upon the
hours of operation and the working
environment. Compressor units in an
extremely dirty and/or hostile
3. Remove the air tool or
accessory.
4. Pull ring on safety valve allowing
air to bleed from the tank until
tank pressure is approximately
20 psi. Release safety valve ring.
environment will require a greater
frequency of all maintenance checks.
5. Drain water from air tank by
opening drain valve (counter-
clockwise) on bottom of tank.
Water will
condense in the air
tank. If not drained, water will
corrode and weaken the air tank
causing a risk of air tank rupture.
15- ENG
D24456
Download from Www.Somanuals.com. All Manuals Search And Download.
6. After the water has been drained,
close the drain valve (clockwise).
The air compressor can now be
stored.
Air Compressor Pump Intake
and Exhaust Valves
Once a year have a Trained Service
Technician check the air compressor
pump intake and exhaust valves.
NOTE: If drain valve is plugged,
release all air pressure. The valve
can then be removed, cleaned, the
reinstalled.
Motor
The motor has an automatic reset
thermal overload protector. If the
motor overheats for any reason, the
overload protector will shut off the
motor. The motor must be allowed to
cool down before restarting. The
compressor will automatically restart
after the motor cools.
Air Filter - Inspection and
Replacement
Hot surfaces. Risk
of burn.
Compressor heads are exposed
when filter cover is removed.
Allow compressor to cool prior to
servicing.
If the overload protector shuts the
motor off frequently, check for a
possible voltage problem. Low
voltage can also be suspected when:
Keep the air filter
clean at all times.
Do not operate the air compressor
with the air filter removed.
1. The motor does not get up to full
power or speed.
A dirty air filter will not allow the
compressor pump to operate at full
capacity. Before you use the
compressor pump, check the air filter
to be sure it is clean and in place.
2. Fuses blow out when starting
the motor; lights dim and remain
dim when motor is started and is
running.
If it is dirty, replace it with a new filter.
On some models,the filter may be
removed by using a pair of needle
nose pliers or a screwdriver. Pull or
pry out the old filter and carefully
clean the filter area. Push in the new
air filter.
16- ENG
D24456
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICE AND ADJUSTMENTS
Unit cycles
automatically when
power is on. When doing
Maintenance, you may be exposed
to voltage sources, compressed air
or moving parts. Personal injuries
can occur. Before performing any
Maintenance or repair, unplug the
compressor and bleed off all air
pressure.
4. Using an adjustable wrench
loosen pressure relief tube nut at
air tank and pressure switch.
Carefully move pressure relief
tube away from check valve.
5. Unscrew the check valve (turn
counterclockwise) using a 7/8"
open end wrench. Note the
orientation for reassembly.
6. Using a screwdriver, carefully
push the valve disc up and
down. NOTE: The valve disc
should move freely up and down
on a spring which holds the valve
disc in the closed position, if not
the check valve needs to be
cleaned or replaced.
ALL MAINTENANCE AND REPAIR
OPERATIONS NOT LISTED MUST
BE PERFORMED BY TRAINED
SERVICE TECHNICIAN.
Before servicing:
•
Unplug or disconnect electrical
supply to the air compressor.
•
•
Bleed tank of pressure.
Allow the air compressor to cool.
Screwdriver
In open
To Replace or Clean Check
Valve
position
nothing is
visible.
1. Release all air pressure from air
tank. See "To Drain Tank" in the
Maintenance section.
In closed position
disc is visible.
7. Clean or replace the check valve.
A solvent, such as paint or
2. Unplug unit.
3. Using an adjustable wrench
loosen outlet tube nut at air tank
and pump. Carefully move outlet
tube away from check valve.
varnish remover can be used to
clean the check valve.
8. Apply sealant to the check valve
threads. Reinstall the check valve
(turn clockwise).
Pressure
Relief Tube
Nut
9. Replace the pressure release
tube. Tighten nuts.
10. Replace the outlet tube and
tighten nuts.
Outlet
Tube
11. Perform the Break-in Procedure.
See "Break-in Procedure" in the
Operation section.
Nut
Check
Valve
17- ENG
Download from Www.Somanuals.com. All Manuals Search And Download.
D24456
STORAGE
Before you store the air compressor,
make sure you do the following:
Water will
condense in the air
tank. If not drained, water will
corrode and weaken the air tank
causing a risk of air tank rupture.
1. Review the "Maintenance"
section on the preceding pages
and perform scheduled
maintenance as necessary.
7. After the water has been drained,
close the drain or drain valve.
2. Set the On/Auto/Off lever to
"OFF".
NOTE: If drain valve is plugged,
release all air pressure. The valve
can then be removed, cleaned, then
reinstalled.
3. Turn the regulator
counterclockwise and set the
outlet pressure to zero.
8. Protect the electrical cord and air
hose from damage (such as
being stepped on or run over).
Wind them loosely around the
compressor handle.
4. Remove the air tool or
accessory.
5. Pull ring on safety valve allowing
air to bleed from the tank until
tank pressure is approximately
20 psi. Release safety valve ring.
Store the air compressor in a clean
and dry location.
6. Drain water from air tank by
opening drain valve on bottom
of tank.
18- ENG
D24456
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING
Performing repairs may expose voltage sources, moving
parts or compressed air sources, moving parts or
compressed air sources. Personal injury may occur. Prior to attempting
any repairs, unplug the air compressor and bleed off all air tank air
pressure.
CAUSE
CORRECTION
PROBLEM
Excessive tank
pressure -
safety valve
pops off.
Pressure switch does not
shut off motor when
compressor reaches "cut-
out" pressure.
Move On/Auto/Off lever to
the "OFF" position, if the
unit does
not shut off contact a
Trained Service Technician.
Contact a Trained Service
Technician.
Pressure switch "cut-out"
too high.
Tighten fittings where air can
be heard escaping. Check
fittings with soapy water
solution. DO NOT
Air leaks at
fittings.
Tube fittings are not tight
enough.
OVERTIGHTEN.
A defective check valve
results in a constant air leak
at the pressure release valve
when there is pressure in the
tank and the compressor is
shut off. Replace check
valve. Refer the "To Replace
or Clean Check Valve" in the
"Service and Adjustment"
section.
Air leaks at or
inside check
valve.
Check valve seat damaged.
Air leaks at
Defective pressure switch
release valve.
Contact a Trained Service
Technician.
pressure switch
release valve.
(if equipped)
Air tank must be replaced.
Do not repair the leak.
Do not
Air leaks in air
tank or at air
tank welds.
Defective air tank.
drill into,
weld or otherwise modify
air tank or it will weaken.
The tank can rupture or
explode.
Leaking seal.
Air leaks
between head
and valve plate.
Contact a Trained Service
Technician.
19- ENG
D24456
Download from Www.Somanuals.com. All Manuals Search And Download.
PROBLEM
CORRECTION
CAUSE
If there is an excessive amount
of pressure drop when the
accessory is used, adjust the
regulator as instructed in the
Operation section.
NOTE: Adjust the regulated
pressure under flow conditions
(while accessory is being
used).
It is normal for "some"
pressure drop to occur.
Pressure reading
on the regulated
pressure gauge
(if equipped)
drops when an
accessory is
used.
Operate safety valve manually
by pulling on ring. If valve still
leaks, it should be replaced.
Air leak from
safety valve.
Possible defect in safety
valve.
Decrease amount of air usage.
Prolonged excessive use of
air.
Compressor is not large
enough for air requirement.
Compressor is
not supplying
enough air to
operate
Check the accessory air
requirement. If it is higher than
the SCFM or pressure supplied
by your air compressor, you
need a larger compressor.
Check and replace if required.
accessories.
Hole in hose.
Remove and clean, or replace.
Tighten fittings.
Check valve restricted.
Air leaks.
Clean or replace air intake
filter. Do not operate the air
compressor with the filter
removed. Refer to the "Air
Filter" paragraph in the
Restricted air intake filter
"Maintenance " section.
Clean or replace. See Air Filter
paragraph in the Maintenance
section.
Restricted air
intake.
Dirty air filter.
Regulator knob Damaged regulator.
has continuous
Have checked by a Trained
Service Technician.
air leak.
Damaged regulator.
Have checked by a Trained
Service Technician.
Regulator will
not shut off air
outlet.
20- ENG
Download from Www.Somanuals.com. All Manuals Search And Download.
D24456
PROBLEM
CORRECTION
CAUSE
Let motor cool off and
overload switch will
automatically reset.
Motor will not
run.
Motor overload protection
switch has tripped.
Motor will start automatically
when tank pressure drops
below "cut-in" pressure of
pressure switch.
Tank pressure exceeds
pressure switch "cut-in"
pressure.
Remove and clean, or replace.
Check valve stuck open.
Check wiring connection
inside pressure switch and
terminal box area.
Loose electrical
connections.
Possible defective motor
or starting capacitor.
Have checked by a Trained
Service Technician.
Have checked by a Trained
Service Technician. Do not
operate the compressor in the
paint spray area. See
Paint spray on internal
motor parts.
flammable vapor warning.
Pressure release valve on
pressure switch has not
unloaded head pressure.
Bleed the line by pushing the
lever on the pressure switch to
the "off" position; if the valve
does not open, replace switch.
Fuse blown, circuit breaker
tripped.
1. Check fuse box for blown
fuse and replace as
necessary. Reset circuit
breaker. Do not use a fuse
or circuit breaker with
higher rating than that
specified for your
particular branch circuit.
2. Check for proper fuse. You
should use a time delay
fuse.
3. Check for low voltage
conditions and/or proper
extension cord.
4. Disconnect the other
electrical appliances from
circuit or operate the
compressor on its own
branch circuit.
Knocking Noise. Possible defect in safety
valve.
Operate safety valve manually
by pulling on ring. If valve still
leaks, it should be replaced.
Defective check valve.
Remove and clean, or replace.
21- ENG
D24456
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE DES MATIÈRES
GARANTIE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
TABLEAU DES SPÉCIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
MESURES DE SÉCURITÉ - DÉFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
CONSIGNES DE SÉCURITÉ IMPORTANTES . . . . . . . . . . . . . . . . . . . . . . . . . . .27-32
LEXIQUE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
ACCESSOIRES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
CYCLE DE SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
ASSEMBLAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34-35
UTILISATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36-38
ENTRETIEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39-40
INTRETIEN ET RÉGLAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
RANGEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
GUIDE DE DÉPANNAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43-45
DIAGRAMME DU COMPRESSEUR D'AIR / LISTE DES PIÈCES . . . . . . . . . . . .46-49
POUR PLACER UNE COMMANDE DE PIÈCES DE RECHANGE . .Couverture Arrière
GARANTIE
GARANTIE COMPLÈTE DE UN AN SUR LES COMPRESSEURS D’AIR
Ce compresseur d’air est garanti contre tout défaut de fabrication pour une période de
un an, à compter de la date d’achat. Au cours de cette période de garantie, SEARS
S’ENGAGE À LE RÉPARER SANS FRAIS. IL SUFFIT DE LE RETOURNER AU CENTRE
DE SERVICE APRÈS-VENTE SEARS LE PLUS PROCHE. LES CENTRES DE SERVICE
APRÈS-VENTE SONT RÉPARTIS DANS TOUT LE CANADA.
Cette garantie ne s’applique que pour une période de quatre-vingt-dix (90) jours
seulement, à compter de la date d’achat, sur un compresseur qui est utilisé à des fins
commerciales ou comme appareil de location
Cette garantie sur le compresseur d'air de Craftsman vous donne des droits
particuliers. Il se peut que vous ayez d’autres droits qui varient d’une province à l’autre.
Sears Canada, Inc., Toronto, Ont. M5B 2B8
26- FR
D24456
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLEAU DES SPÉCIFICATIONS
Modèle no :
919-724580
CV maximum développés
3
Alésage
2,375 po (6,0 cm)
Course du cylindre
1,35 po (3,4 cm)
Tension – phase unique
120
Exigence minimale du circuit de dérivation
Genre de fusible
15 a
à retardement à élément double
Capacité du réservoir d’air
Pression d’enclenchement approx.
Pression de coupe-circuit approx.
Pi3/min standard (SCFM) à 40 psi (lb/po. ca.)
Pi3/min standard (SCFM) à 90 psi (lb/po. ca.)
4 gal. (15,1 L)
120
150
7,9
5,5
MESURES DE SÉCURITÉ - DÉFINITIONS
SÉCURITÉ ET PRÉVENTION DE PROBLÈMES D’ÉQUIPEMENT. Afin de vous aider à
identifier cette information, nous avons utilisé des signes de danger plus bas. Veuillez lire
attentivement ce guide en portant une attention particulière à ces sections.
Indique un danger
imminent qui, s'il n'est
Indique la
possibilité d'un
pas évité, causera de graves blessures
ou la mort.
danger qui, s'il n'est pas évité,
peut causer des blessures mineures ou
moyennes.
Indique
la
Sans le symbole d’alerte.
Indique la possibilité d’un
danger qui, s’il n’est pas évité, peut causer
des dommages à la propriété.
possibilité d’un
danger qui, s’il n’est pas évité, pourrait
causer de graves blessures ou la mort.
CONSIGNES DE SÉCURITÉ IMPORTANTES
CONSERVER CES DIRECTIVES
UN EMPLOI OU UN ENTRETIEN NON APPROPRIÉS DE CE PRODUIT PEUT CAUSER
DES BLESSURES GRAVES ET DES DOMMAGES À LA PROPRIÉTÉ. LIRE
ATTENTIVEMENT TOUS LES AVERTISSEMENTS ET LES DIRECTIVES D’UTILISATION
AVANT D’UTILISER CET APPAREIL.
La poussière produite par le ponçage électrique le sciage, le
meulage, le perçage et autres activités de construction peut
contenir des produits chimiques qui sont reconnus, par l'état de la Californie, de causer le
cancer, les anomalies congénitales ou autres maux de reproduction. Ces produits chimiques
comprennent, entre autres :
ꢀ
ꢀ
ꢀ
le plomb provenant des peintures à base de plomb;
la silice cristalline provenant de briques, de béton ou d'autres produits de maçonnerie
l'arsenic et le chrome provenant du bois de charpente traité chimiquement
Le risque d'exposition à ces produits dépend de la fréquence d'exécution de ce genre de travaux.
Afin de réduire l'exposition à ces produits chimiques, travaillez dans un endroit bien aéré et utilisez de
l'équipement de sécurité approuvé, portez toujours un masque facial ou respirateur homologué
MSHA/NIOSH bien ajusté lorsque vous utilisez de tels outils.
Lorsque vous utilisez un outil pneumatique, il faut toujours suivre les mesures de sécurité de base afin
de réduire le risque de blessures corporelles.
27- FR
D24456
Download from Www.Somanuals.com. All Manuals Search And Download.
DANGER
RISQUE D’EXPLOSION OU D’INCENDIE
RISQUE
PRÉVENTION
LES ÉTINCELLES QUI PROVIENNENT DES
CONTACTS ÉLECTRIQUES DU MOTEUR ET
DU MANOSTAT SONT CONSIDÉRÉES
NORMALES.
TOUJOURS UTILISER LE COMPRESSEUR
DANS UN ENDROIT BIEN AÉRÉ, LOIN DE
TOUTE MATIÈRE COMBUSTIBLE ET DES
VAPEURS D’ESSENCE OU DE SOLVANTS.
SI DES ÉTINCELLES ÉLECTRIQUES DU
COMPRESSEUR ENTRENT EN CONTACT
AVEC DES VAPEURS INFLAMMABLES,
ELLES PEUVENT S’ENFLAMMER,
PROVOQUANT UN INCENDIE OU UNE
EXPLOSION.
SI DES MATIÈRES INFLAMMABLES DOIVENT
ÊTRE VAPORISÉES, SITUER LE
COMPRESSEUR À UNE DISTANCE D’AU
MOINS 20 PIEDS DE LA ZONE DE
VAPORISATION. IL PEUT S’AVÉRER
NÉCESSAIRE D’UTILISER UN BOYAU
SUPPLÉMENTAIRE.
ENTREPOSER LES MATIÈRES
INFLAMMABLES DANS UN ENDROIT
SÉCURITAIRE, LOIN DU COMPRESSEUR.
TOUTE OBSTRUCTION DES ORIFICES
D’AÉRATION DU COMPRESSEUR
ENTRAÎNERA UNE SURCHAUFFE
DANGEREUSE ET RISQUE DE CAUSER UN
INCENDIE.
NE JAMAIS PLACER DES OBJETS CONTRE
OU SUR LE COMPRESSEUR. UTILISER LE
COMPRESSEUR DANS UN ENDROIT OUVERT,
À AU MOINS 12 POUCES (30 cm) DE TOUT
MUR OU OBSTRUCTION QUI RÉDUIT LE
DÉBIT D’AIR FRAIS VERS LES ORIFICES
D’AÉRATION.
UTILISER LE COMPRESSEUR DANS UN
ENDROIT PROPRE, SEC ET BIEN AÉRÉ. NE
PAS UTILISER L’APPAREIL À L’INTÉRIEUR
OU DANS UN ENDROIT CLOS.
SI CET APPAREIL FONCTIONNE SANS
SUPERVISION, CELA RISQUE DE CAUSER
DES BLESSURES GRAVES OU DES
DOMMAGES À LA PROPRIÉTÉ. POUR
RÉDUIRE LE RISQUE D'INCENDIE, NE
JAMAIS LAISSER LE COMPRESSEUR D'AIR
FONCTIONNER SANS SUPERVISION.
TOUJOURS RESTER À PROXIMITÉ DE
L’APPAREIL LORSQU’IL EST EN FONCTION.
TOUJOURS COUPER L'ALIMENTATION
ÉLECTRIQUE EN PLAÇANT LE LEVIER DU
MANOSTAT À LA POSITION D'ARRÊT "OFF"
ET VIDANGER LE RÉSERVOIR CHAQUE
JOUR OU APRÈS CHAQUE USAGE.
28- FR
Download from Www.Somanuals.com. All Manuals Search And Download.
D24456
DANGER
RISQUE D’ÉCLATEMENT
RÉSERVOIR D’AIR : LES CONDITIONS SUIVANTES PEUVENT AFFAIBLIR LES PAROIS DU
RÉSERVOIR ET PROVOQUER UNE EXPLOSION VIOLENTE DU RÉSERVOIR QUI RISQUE DE
CAUSER DES DOMMAGES À LA PROPRIÉTÉ OU DES BLESSURES GRAVES.
RISQUE
PRÉVENTION
1.
LE DÉFAUT DE VIDANGER DE FAÇON
APPROPRIÉE L’EAU CONDENSÉE
DANS LE RÉSERVOIR RISQUE DE
CAUSER LA ROUILLE ET
L’AMINCISSEMENT DES PAROIS EN
ACIER DU RÉSERVOIR.
PURGER LE RÉSERVOIR QUOTIDIENNEMENT
OU APRÈS CHAQUE UTILISATION. SI LE
RÉSERVOIR ACCUSE UNE FUITE, LE
REMPLACER IMMÉDIATEMENT PAR UN
NOUVEAU RÉSERVOIR OU REMPLACER LE
COMPRESSEUR AU COMPLET.
2.
3.
DES MODIFICATIONS OU TENTATIVES
DE RÉPARATION FAITES SUR LE
RÉSERVOIR.
NE JAMAIS PERFORER AVEC UNE
PERCEUSE, SOUDER OU FAIRE UNE
MODIFICATION QUELCONQUE AU
RÉSERVOIR OU À SES ACCESSOIRES.
DES MODIFICATIONS NON
LE RÉSERVOIR EST CONÇU POUR SUBIR DES
PRESSIONS DE SERVICE PARTICULIÈRES. NE
JAMAIS EFFECTUER DES RÉGLAGES NI
SUBSTITUER DES PIÈCES POUR MODIFIER
LES PRESSIONS DE SERVICE ÉTABLIES À
L’USINE.
AUTORISÉES APPORTÉES À LA
SOUPAPE DE DÉCHARGE, À LA
SOUPAPE DE SÛRETÉ OU À TOUTE
AUTRE COMPOSANTE QUI CONTRÔLE
LA PRESSION DU RÉSERVOIR.
4.
DES VIBRATIONS EXCESSIVES
PEUVENT AFFAIBLIR LE RÉSERVOIR
ET CAUSER UNE RUPTURE OU UNE
EXPLOSION.
POUR LE CONTRÔLE ESSENTIEL DE LA
PRESSION D’AIR, IL FAUT POSER UN
FIXATIONS ET ACCESSOIRES :
LE FAIT D’EXCÉDER LA PRESSION
NOMINALE DES OUTILS PNEUMATIQUES,
PISTOLETS PULVÉRISATEURS,
ACCESSOIRES PNEUMATIQUES, PNEUS ET
AUTRES OBJETS GONFLABLES RISQUE DE
PROVOQUER L’EXPLOSION DE CES
DERNIERS ET LA PROJECTION DE PIÈCES,
CE QUI RISQUE DE CAUSER DE GRAVES
BLESSURES.
RÉGULATEUR DE PRESSION (S’IL N’EST PAS
DÉJÀ POSÉ ET UN MANOMÈTRE À LA
SORTIE D’AIR DU COM-PRESSEUR). SUIVRE
LES RECOMMANDATIONS DU FABRICANT DE
L’ÉQUIPEMENT ET NE JAMAIS EXCÉDER LA
VALEUR NOMINALE DE PRESSION SPÉCIFIÉE
DES ACCESSOIRES. NE JAMAIS UTILISER LE
COMPRESSEUR POUR GONFLER DES
OBJETS À FAIBLE PRESSION, TELS QUE LES
JOUETS D’ENFANT, LES BALLONS DE
FOOTBALL OU DE BASKET-BALL, ETC.
DANGER
RISQUE DE PROJECTION D’OBJETS
RISQUE
PRÉVENTION
PORTER TOUJOURS DES LUNETTES DE
PROTECTION HOMOLOGUÉES ANSI Z87.1
AVEC DES ÉCRANS LATÉRAUX LORS DE
L’UTILISATION DU COMPRESSEUR.
LE JET D’AIR COMPRIMÉ PEUT CAUSER
DES LÉSIONS AUX TISSUS DE LA PEAU
EXPOSÉE ET PEUT PROJETER DE LA
SALETÉ, DES COPEAUX, DES PARTICULES
LIBRES ET DE PETITS OBJETS À HAUTE
VITESSE, CE QUI RISQUE DE CAUSER DES
DOMMAGES À LA PROPRIÉTÉ OU DES
BLESSURES.
NE JAMAIS DIRIGER LA BUSE OU LE
VAPORISATEUR VERS SOI, VERS D’AUTRES
PERSONNES OU VERS DES ANIMAUX.
TOUJOURS METTRE LE COMPRESSEUR
HORS FONCTION ET PURGER LA PRESSION
DU BOYAU D’AIR ET DU RÉSERVOIR AVANT
D’ENTAMER L’ENTRETIEN OU D’ATTACHER
DES OUTILS OU ACCESSOIRES.
29- FR
Download from Www.Somanuals.com. All Manuals Search And Download.
D24456
DANGER
RISQUE DE CHOC ÉLECTRIQUE
RISQUE
PRÉVENTION
NE JAMAIS FAIRE FONCTIONNER LE
COMPRESSEUR À L’EXTÉRIEUR LORSQU’IL
PLEUT OU DANS DES CONDITIONS HUMIDES.
NE JAMAIS FAIRE FONCTIONNER LE
COMPRESSEUR SANS LES COUVERCLES
DE PROTECTION OU LORSQUE CEUX-CI
SONT ENDOMMAGÉS.
VOTRE COMPRESSEUR D’AIR EST
ALIMENTÉ PAR ÉLECTRICITÉ. COMME
AVEC TOUS LES APPAREILS ÉLECTRIQUES,
SI L’APPAREIL N’EST PAS UTILISÉ DE
FAÇON APPROPRIÉE, IL PEUT CAUSER DES
CHOCS ÉLECTRIQUES.
TOUT CÂBLAGE ÉLECTRIQUE OU TOUTE
RÉPARATION REQUIS SUR CET APPAREIL
DEVRAIT ÊTRE EFFECTUÉ PAR LE
PERSONNEL D’UN CENTRE DE SERVICE
APRÈS-VENTE AUTORISÉ, CONFORMÉMENT
AUX CODES ÉLECTRIQUES NATIONAUX ET
LOCAUX.
TOUTE RÉPARATION EFFECTUÉE PAR UNE
PERSONNE NON QUALIFIÉE PEUT
ENTRAÎNER DES BLESSURES GRAVES OU
LA MORT PAR ÉLECTROCUTION.
S’ASSURER QUE LE CIRCUIT ÉLECTRIQUE
ALIMENTANT LE COMPRESSEUR FOURNIT
UNE MISE À LA TERRE ÉLECTRIQUE
APPROPRIÉE, UNE TENSION APPROPRIÉE
ET UNE PROTECTION ADÉQUATE PAR
FUSIBLES.A
MISE À LA TERRE : LE DÉFAUT D’ÉTABLIR
UNE MISE À LA TERRE APPROPRIÉE POUR
CET APPAREIL PEUT ENTRAÎNER DES
BLESSURES GRAVES OU LA MORT PAR
ÉLECTROCUTION. VOIR LES DIRECTIVES DE
MISE À LA TERRE.
DANGER
RISQUE PAR INHALATION
RISQUE
PRÉVENTION
L'AIR OBTENU DIRECTEMENT DU
L'AIR COMPRIMÉ DE VOTRE
COMPRESSEUR NE DEVRAIT JAMAIS ÊTRE
UTILISÉ COMME SOURCE D'AIR POUR LES
ÊTRE HUMAINES. SI L'AIR PRODUIT PAR CE
COMPRESSEUR SERA UTILISÉ POUR LA
RESPIRATION, IL FAUT INSTALLER DES
FILTRES APPROPRIÉS AINSI QUE DU
MATÉRIEL DE SÉCURITÉ. LES FILTRES EN
LIGNE ET LE MATÉRIEL DE SÉCURITÉ
UTILISÉS AVEC LE COMPRESSEUR DOIVENT
ÊTRE DANS LA MESURE DE TRAITER L'AIR
DE FAÇON À CE QU'IL RÉPONDE À TOUTES
LES NORMES NATIONALES ET LOCALES
APPLICABLES AVANT D'ÊTRE UTILISÉ POUR
LES ÊTRES HUMAINES.
COMPRESSEUR D'AIR N'EST PAS
SÉCURITAIRE POUR L'INHALATION. LE JET
D'AIR PEUT CONTENIR DU MONOXYDE DE
CARBONE, DES VAPEURS TOXIQUES OU
DES PARTICULES SOLIDES DU RÉSERVOIR.
L'INHALATION DE CES CONTAMINANTS
PEUT CAUSER DES BLESSURES GRAVES
OU LA MORT.
LES MATIÈRES VAPORISÉES TELLES QUE LA
PEINTURE, LES SOLVANTS DE PEINTURE, LES
DÉCAPANTS, LES INSECTICIDES ET LES
HERBICIDES CONTIENNENT DES VAPEURS
NOCIVES ET TOXIQUES.
TRAVAILLER DANS UN ENDROIT OÙ IL Y A
UNE BONNE VENTILATION TRANSVERSALE.
BIEN LIRE ET RESPECTER LES DIRECTIVES
DE SÉCURITÉ INDIQUÉES SUR L’ÉTIQUETTE
OU LA FICHE SIGNALÉTIQUE DE LA MATIÈRE
QUI EST VAPORISÉE. PORTER UN
RESPIRATEUR HOMOLOGUÉ PAR LE
NIOSH/MSHA ET CONÇU POUR
L’APPLICATION EN QUESTION.
30- FR
D24456
Download from Www.Somanuals.com. All Manuals Search And Download.
DANGER
RISQUE DE BRÛLURES
PRÉVENTION
RISQUE
LE FAIT DE TOUCHER AUX SURFACES DE
MÉTAL EXPOSÉES TELLES QUE LA TÊTE DU
COMPRESSEUR OU LES TUBES DE SORTIE
PEUT CAUSER DE GRAVES BRÛLURES À LA
PEAU.
NE JAMAIS TOUCHER AUX PIÈCES DE
MÉTAL EXPOSÉES DU COMPRESSEUR
DURANT OU IMMÉDIATEMENT APRÈS LE
FONCTIONNEMENT. LE COMPRESSEUR
DEMEURE CHAUD PENDANT PLUSIEURS
MINUTES APRÈS LE FONCTIONNEMENT.
NE PAS TENTER D’ATTEINDRE LES
COMPOSANTES DERRIÈRE LES GARDES DE
PROTECTION ET NE PAS EFFECTUER DE
L’ENTRETIEN AVANT D’AVOIR LAISSÉ
REFROIDIR L’APPAREIL.
DANGER
RISQUE RELIÉ AUX PIÈCES MOBILES
RISQUE
PRÉVENTION
LES PIÈCES MOBILES TELLES QUE LA
POULIE, LE VOLANT-MOTEUR ET LA
COURROIE PEUVENT ENTRAÎNER DES
BLESSURES GRAVES SI ELLES ENTRENT EN
CONTACT AVEC UNE PARTIE DU CORPS OU
DES VÊTEMENTS.
NE JAMAIS FAIRE FONCTIONNER LE
COMPRESSEUR SANS LES GARDES OU LES
COUVERCLES OU LORSQUE CEUX-CI SONT
ENDOMMAGÉS.
TOUTE RÉPARATION REQUISE SUR CET
APPAREIL DEVRAIT ÊTRE EFFECTUÉE PAR LE
PERSONNEL D’UN CENTRE DE SERVICE
APRÈS-VENTE AUTORISÉ.
EN TENTANT DE FAIRE FONCTIONNER LE
COMPRESSEUR AVEC DES PIÈCES
MANQUANTES OU ENDOMMAGÉES, OU DE
RÉPARER LE COMPRESSEUR SANS LES
GARDES DE PROTECTION, ON S’EXPOSE
AUX PIÈCES MOBILES, CE QUI PEUT
ENTRAÎNER DES BLESSURES GRAVES.
DANGER
RISQUE DE CHUTE
RISQUE
PRÉVENTION
TOUJOURS S’ASSURER DE LA STABILITÉ DU
COMPRESSEUR AVANT DE LE FAIRE
FONCTIONNER AFIN DE PRÉVENIR TOUT
MOUVEMENT ACCIDENTEL DE L’APPAREIL. NE
JAMAIS UTILISER UN COMPRESSEUR SUR
UN TOIT OU DANS UNE POSITION ÉLEVÉE ;
UTILISER PLUTÔT UN BOYAU D’AIR
SUPPLÉMENTAIRE POUR ATTEINDRE LES
ENDROITS ÉLEVÉS.
UN COMPRESSEUR PORTATIF PEUT
TOMBER D’UNE TABLE, D’UN ÉTABLI OU
D’UN TOIT. L’IMPACT PEUT CAUSER DES
DOMMAGES AU COMPRESSEUR ET DES
BLESSURES CORPORELLES OU LA MORT
DE L’UTILISATEUR.
31- FR
Download from Www.Somanuals.com. All Manuals Search And Download.
D24456
DANGER
RISQUE DE DOMMAGES À LA PROPRIÉTÉ PENDANT LE TRANSPORT
DU COMPRESSEUR
(incendie, inhalation, dommages aux surfaces du véhicule)
RISQUE
PRÉVENTION
DES FUITES OU DES DÉVERSEMENTS
D’HUILE PEUVENT SE PRODUIRE ET
TOUJOURS PLACER LE COMPRESSEUR SUR
UN TAPIS DE PROTECTION POUR ÉVITER
L’ENDOMMAGEMENT DU VÉHICULE PAR DES
FUITES. RETIRER LE COMPRESSEUR DU
VÉHICULE IMMÉDIATEMENT À L’ARRIVÉE.
ENTRAÎNER DES RISQUES D’INCENDIE, OU
DES PROBLÈMES AUX VOIES RESPIRATOIRES,
DES BLESSURES GRAVES OU LA MORT. DES
FUITES D’HUILE ENDOMMAGENT LES TAPIS,
LA PEINTURE ET TOUTE AUTRE SURFACE DES
VÉHICULES OU DES REMORQUES.
DANGER
RISQUE D'UNE UTILISATION DANGEREUSE
RISQUE
PRÉVENTION
UNE UTILISATION DANGEREUSE DE VOTRE
COMPRESSEUR D'AIR POURRAIT CAUSER
DES BLESSURES GRAVES OU LA MORT DE
L'UTILISATEUR OU D'AUTRES PERSONNES.
LISEZ ATTENTIVEMENT TOUS LES
INSTRUCTIONS ET LES AVERTISSEMENTS
FIGURANT DANS CE GUIDE.
FAMILIARISEZ-VOUS AVEC LE
FONCTIONNEMENT ET LES COMMANDES DU
COMPRESSEUR D'AIR.
GARDEZ LES ENFANTS, LES ANIMAUX DE
COMPAGNIE ET LES OBSTACLES ÉLOIGNÉS
DU COMPRESSEUR D'AIR À TOUT TEMPS.
N'UTILISEZ PAS LE PRODUIT LORSQUE VOUS
ÊTES FATIGUÉ OU SOUS L'INFLUENCE
D'ALCOOL OU DE DROGUES.
RESTEZ ALERTE À TOUT MOMENT.
NE TENTEZ JAMAIS D'ANNULER LES
CARACTÉRISTIQUES DE SÉCURITÉ DE CE
PRODUIT.
ASSUREZ-VOUS QU'UN EXTINCTEUR
D'INCENDIE EST DISPONIBLE DANS L'AIRE
DE TRAVAIL.
N'UTILISEZ PAS L'APPAREIL AVEC DES
PIÈCES BRISÉES, MANQUANTES OU NON
AUTORISÉES.
32- FR
Download from Www.Somanuals.com. All Manuals Search And Download.
D24456
LEXIQUE
tandis qu'on continue d'utiliser l'accessoire.
Quand la pression du réservoir tombe à un niveau
bas réglé à l'usine, le moteur se remet
automatiquement en marche. La basse pression à
laquelle le moteur se remet automatiquement en
marche s'appelle la "pression d'amorçage".
Pression de rupture : Lorsqu'on met un
compresseur d'air en marche et qu'il commence
à fonctionner, la pression d'air dans le réservoir
commence à s'accumuler. La pression monte et
atteint un niveau élevé réglé à l'usine, avant que le
moteur ne s'arrête automatiquement, protégeant
ainsi le réservoir d'air d'un taux de pression qui
excèderait sa capacité. La haute pression à
laquelle le moteur s'arrête s'appelle la "pression
de rupture".
Veuillez vous familiariser avec ces termes avant
d'utiliser l'appareil.
CFM : pieds cubes par minute (pi3/min).
SCFM : pieds cubes par minute (pi3/min)
standard. Une unité de mesure de débit d'air.
PSIG: jauge indiquant le nombre de livres par
pouce carré (lb/po2). Une unité de mesure de
pression.
ASME : American Society of Mechanical
Engineers. Fabriqué, mis à l'essai, inspecté et
enregistré pour répondre aux normes de la ASME.
Codes de certification : Les produits portant une
ou plusieurs des mentions suivantes (UL, CUL,
ETL, CETL) ont été évalués par des laboratoires
indépendants de sécurité certifiés par l'OSHA et
répondent aux normes de sécurité applicables
des Underwriters Laboratories.
Circuit de dérivation : Le circuit acheminant
l'électricité du tableau électrique vers la prise
murale.
Pression d'amorçage : Lorsque le moteur est
arrêté, la pression du réservoir d'air s'abaisse
ACCESSOIRES
Cet appareil peut alimenter les accessoires suivants. Les accessoires figurent dans le Catalogue
actuel des outils électriques et manuels et sont également disponibles des magasins Sears
vendant nos gammes complètes.
• Dispositifs de lubrification à bruine
d'huile
• Boyau d'air : 1/4 po, 3/8 po ou 1/2 po
(diam. int.), diverses longueurs
Accessoires
• Filtre en ligne
• Raccord de gonflage pour pneus
• Jeu de raccords à connexion rapide
(diverses dimensions)
• Régulateurs de pression d'air
Consultez le tableau de sélection situé sur
l'appareil pour choisir les outils qui
peuvent être alimentés avec cet appareil.
CYCLE DE SERVICE
compresseur d'air n'est pas assez
puissant pour répondre aux besoins de
production d'air comprimé. Le temps
d'utilisation maximum du compresseur est
donc 30 minutes par heure.
Les compresseurs d'air ne devraient pas
avoir un cycle de service supérieur à 50%.
Cela veut dire qu'un compresseur qui a
pompé de l'air pendant plus de 50%
d'une heure est considéré comme avoir
subi un mauvais usage parce que le
33- FR
D24456
Download from Www.Somanuals.com. All Manuals Search And Download.
ASSEMBLAGE
Déballage
1. Retirez l'appareil de sa boîte et jetez
tout l'emballage.
INSTALLATION
2.
Assurez-vous que la prise de courant
utilisée a la même configuration que la
fiche de mise à la terre. NE PAS
UTILISER UN ADAPTATEUR. Voir
l'illustration.
MONTAGE DE L'APPAREIL
Emplacement du compresseur d'air
Le compresseur d'air doit être situé dans un
endroit propre, sec et bien aéré. Le
compresseur d'air doit être situé à une
distance d'au moins 12 po (30 cm) du mur ou
de toute autre obstruction qui pourrait nuire au
débit d'air. La pompe et la tôle de protection
du compresseur sont conçus pour permettre
un refroidissement approprié. Les ouvertures
d'aération du compresseur sont nécessaires
pour maintenir la température de
Fiche
Prises de
courant
mises à la
terre
Broche de mise à la terre
fonctionnement appropriée. Ne placez pas de
chiffons ou de contenants sur ou à proximité
de ces ouvertures.
3.
4.
Inspectez la fiche et le cordon avant
chaque utilisation. Ne pas les utiliser s'il y
a des signes de dommages.
DIRECTIVES DE MISE À LA TERRE
Si vous ne comprenez pas tout à fait ces
directives de mise à la terre, ou s'il y a
des doutes que le compresseur soit mis
à la terre de manière appropriée, faire
vérifier l'installation par un électricien
qualifié.
RISQUE DE
CHOCS
ÉLECTRIQUES ! En cas de court-circuit, la
mise à la terre réduit le risque de choc en
fournissant un fil de fuite pour le courant
électrique. Ce compresseur d'air doit être
adéquatement mis à la terre.
UNE MISE À LA TERRE
INAPPROPRIÉE PEUT
ENTRAÎNER DES CHOCS ÉLECTRIQUES.
Ce compresseur d'air portatif est doté d'un
cordon muni d'un fil de mise à la terre et d'une
fiche appropriée de mise à la terre (voir
l'illustration ci-dessous). La fiche doit être
insérée dans une prise de courant installée et
mise à la terre conformément à tous les codes
et ordonnances électriques locaux.
Ne modifiez pas la fiche fournie. Si elle ne
convient pas à la prise de courant
disponible, une prise appropriée doit être
installée par un électricien qualifié.
Toute réparation du cordon ou de la fiche
DOIT être effectuée par un électricien
qualifié
1.
Le cordon fourni avec cet appareil
comprend une fiche avec broche de mise
à la terre. La fiche DOIT être insérée dans
une prise de courant mise à la terre.
IMPORTANT: La prise de courant utilisée doit
être installée et mise à la terre conformément à
tous les codes et ordonnances électriques
locaux.
34- FR
D24456
Download from Www.Somanuals.com. All Manuals Search And Download.
Protection contre la surtension et
protection du circuit
Rallonges
Utilisez un boyau d'air supplémentaire au lieu
d'une rallonge pour éviter une chute de
tension, une perte de puissance et la
surchauffe du moteur.
Consulter le Guide des pièces pour
connaître les exigences minimums
concernant la tension et le circuit de
dérivation.
Si une rallonge doit être utilisée, s'assurer :
Certains modèles de compresseur d'air
peuvent fonctionner sur un circuit de 15
ampères si les conditions suivantes sont
satisfaites :
•
d'utiliser une rallonge à trois fils, munie
d'une fiche à trois lames avec mise à la
terre et une prise de courant à trois
fentes qui accepte la fiche de la rallonge;
1. la tension d'alimentation au circuit de
•
•
•
qu'elle est en bon état;
dérivation est de 15 A;
qu'elle n'excède pas 50 pi (15,5 m);
2. le circuit n'est pas utilisé pour
alimenter d'autres dispositifs
électriques (lumières, appareils
électriques, etc.);
que les fils sont d'un calibre minimum de
12 AWG. (La grosseur du fil augmente
comme le numéro de calibre diminue.
Les fils de calibre 10 AWG et 8 AWG
peuvent également être utilisés. NE PAS
UTILISER UN FIL DE CALIBRE 14 OU 16
AWG.)
3. les rallonges sont conformes aux
spécifications;
4. le circuit est muni d'un coupe-circuit
de 15 A ou d'un fusible retardé de 15
A. REMARQUE : Si un compresseur est
relié à un circuit protégé par des fusibles,
n'utilisez que des fusibles à retardement.
Les fusibles à retardement portent un "D"
au Canada et un "T" aux États-Unis.
Si une des conditions ci-dessus ne peut
être satisfaite, ou si l'utilisation du
compresseur entraîne continuellement une
panne de courant, il sera peut être
nécessaire de brancher le compresseur
sur un circuit de 20 ampères. Il n'est pas
nécessaire de remplacer le cordon dans
un tel cas.
35- FR
D24456
Download from Www.Somanuals.com. All Manuals Search And Download.
UTILISATION
Familiarisez-vous avec votre compresseur d'air
LISEZ CE GUIDE DE L'UTILISATEUR ET TOUTES LES MESURES DE SÉCURITÉ AVANT
D'UTILISER CET APPAREIL. Comparez les illustrations à votre appareil pour vous
familiariser avec l'emplacement des commandes et boutons de réglage. Conservez ce
guide pour références ultérieures.
Manomètre du
réservoir
Pompe du
compresseur
d'air
Manostat
Interrupteur
"On/Auto/Off"
Manomètre
de sortie
Corps
universel à
connexion
rapide
Régulateur
est contrôlée par le régulateur et est
toujours inférieure à ou égale à la pression
du réservoir.
Manomètre du réservoir : Le manomètre
du réservoir indique la pression d'air en
réserve dans le réservoir.
Description du fonctionnement
Familiarisez-vous avec ces commandes
avant d'utiliser l'appareil.
Interrupteur marche/automatique/arrêt
"On/Auto/Off": Placez cet interrupteur à
la position "ON" pour alimenter le
Régulateur : Le régulateur contrôle la
pression d'air indiqué sur le manomètre
de sortie. Tirez le bouton et tournez-le
dans le sens des aiguilles d'une montre
pour augmenter la pression et dans le
sens contraire pour réduire la pression.
Une fois que la pression désirée est
atteinte, poussez le bouton pour le
verrouiller.
Corps universel à connexion rapide : Le
corps universel à connexion rapide
accepte les trois styles les plus en
demande de fiches à connexion rapide,
c'est-à-dire, industriel, automobile (Tru-
flate) et ARO. Le raccordement est simple
et rapide et s'accomplit par une simple
poussée d'une seule main. Les deux
corps à connexion rapide permettent à
l'utilisateur de brancher deux outils à la
fois.
manostat et à la position "OFF" pour
couper le courant après chaque utilisation.
Manostat : Le manostat démarre
automatiquement le moteur lorsque la
pression dans le réservoir d'air tombe à
une valeur inférieure à la "pression
d'amorçage" réglée à l'usine. Il arrête le
moteur lorsque la pression dans le
réservoir d'air atteint la "pression de
rupture" réglée à l'usine.
Soupape de sûreté (non illustré) : Si le
manostat n'arrête pas le compresseur
d'air lorsque la "pression de rupture" est
atteinte, la soupape de sûreté protège
contre toute surpression en "sautant" à la
valeur de pression établie à l'usine (une
pression légèrement supérieure à la
"pression de rupture" établie pour le
manostat.
Manomètre de sortie : Le manomètre de
sortie indique la pression d'air disponible
à la sortie du régulateur. Cette pression
36- FR
D24456
Download from Www.Somanuals.com. All Manuals Search And Download.
Système de refroidissement (non
illustré) :
Ce compresseur d'air offre un système de
refroidissement de pointe. Le cœur de ce
système de refroidissement et un
ventilateur. Il est tout à fait normal que ce
ventilateur souffle une grande quantité
d'air à travers les trous d'aération.
L'expulsion d'air indique que le système
de refroidissement est en fonction.
Soupape de décharge
de pression
Pompe du compresseur d'air: La
pompe comprime l'air pour le forcer dans
le réservoir d'air. L'air n'est pas disponible
pour travailler avant que le compresseur
n'ait élevé la pression du réservoir d'air au
niveau requis à la sortie d'air.
Utilisation de l'appareil
Arrêt de l'appareil :
1. Réglez le levier
marche/automatique/arrêt
"On/Auto/Off" à la position d'arrêt
"OFF".
Robinet de vidange :
Le robinet de vidange est situé à la base
du réservoir d'air et est utilisé pour
vidanger la condensation après chaque
utilisation.
Avant le démarrage
Procédures de rodage
Le
Soupape
de
retenue
compresseur
d'air peut subir d'importants dom-
mages si les procédures de rodage ne
sont pas suivies à la lettre.
Cette procédure doit être exécutée
avant d'utiliser le compresseur d'air
pour la première fois et après le
remplacement de la soupape de
retenue ou de la pompe complète du
compresseur.
1. Assurez-vous que le levier
marche/automatique/arrêt
"On/Auto/Off" est en position d'arrêt
"OFF".
Robinet
de
vidange
Soupape de retenue : Lorsque le
compresseur fonctionne, la soupape de
retenue est "ouverte", permettant à l'air
comprimé d'entrer dans le réservoir d'air.
Quand le compresseur d'air atteint la
"pression de rupture", la soupape de
retenue "se ferme", permettant à l'air
pressurisé de demeurer à l'intérieur du
réservoir d'air.
Soupape de décharge de pression : La
soupape de décharge de pression, située
sur le côté du manostat, est conçue pour
libérer automatiquement l'air comprimé de
la tête du compresseur et du tube de
sortie lorsque le compresseur d'air atteint
la "pression de rupture" ou lorsqu'il est
arrêté. La soupape de décharge de
pression permet au moteur de redémarrer
librement. Lorsque le moteur s'arrête,
vous pouvez toujours entendre l'air sortir
de cette soupape pendant quelques
secondes. Vous ne devriez pas entendre
une fuite d'air lorsque le moteur est en
marche ni une fois que l'appareil a atteint
la "pression de rupture".
REMARQUE: Tirez le raccord vers l'arrière
jusqu'à ce qu'il s'enclenche afin
d'empêcher la fuite d'air du raccord à
connexion rapide.
2. Branchez le cordon d'alimentation
dans la prise de courant du circuit de
dérivation approprié. (Consultez le
paragraphe sur la protection contre la
surtension et la protection du circuit
de la section sur l'installation de ce
guide.)
3. Ouvrez complètement le robinet de
vidange (en tournant dans le sens
contraire des aiguilles d'une montre)
afin de permettre à l'air de sortir et
pour empêcher une accumulation de
pression dans le réservoir d'air lors
de la période de rodage.
37- FR
D24456
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Placez le levier "On/Auto/Off" à la
position "ON/AUTO". Le
Une
pression
compresseur se mettra en marche.
d'air trop élevée conduit à un risque
dangereux d'éclatement. Vérifiez la
pression nominale maximum du
fabricant pour tous les outils
pneumatiques et accessoires utilisés.
La pression de sortie du régulateur ne
doit jamais excéder la pression
nominale maximum.
5. Faire fonctionner le compresseur
pendant 15 minutes. Assurez-vous
que le robinet de vidange est ouvert
et que la pression d'air accumulée
dans le réservoir est minimale.
6. Après 15 minutes, fermez le robinet
de vidange (en tournant dans le sens
des aiguilles d'une montre). Le
réservoir d'air se remplira jusqu'à ce
que la "pression de rupture" soit
atteinte et le moteur s'arrêtera
ensuite.
Mise en marche :
1. Placez le levier "On/Auto/Off" à la
position "AUTO" et attendez jusqu'à
ce que la pression augmente. Le
moteur s'arrêtera lorsque la pression
dans le réservoir atteint la "pression
de rupture".
Le compresseur d'air est maintenant prêt
pour l'utilisation.
2. Tirez le bouton du régulateur et
tournez-le dans le sens des aiguilles
d'une montre pour augmenter la
pression. Une fois que la pression
désirée est atteinte, poussez le
bouton pour le verrouiller. Le
Avant chaque mise en marche :
1. Placez le levier "On/Auto/Off" à la
position "OFF".
2. Tirez le bouton du régulateur et
tournez-le dans le sens contraire des
aiguilles d'une montre jusqu'à ce
qu'il s'arrête. Poussez le bouton pour
le verrouiller.
compresseur d'air est maintenant
prêt pour l'utilisation.
REMARQUE : Utilisez toujours le
compresseur d'air dans une région bien
aérée, sans vapeurs d'essence ni autres
vapeurs combustibles. Si le compresseur
est utilisé avec un vaporisateur, NE PAS
placer le compresseur près de la région
de vaporisation.
3. Raccordez le boyau et les
accessoires. REMARQUE : Le boyau
ou l'accessoire doit être muni d'une
fiche à connexion rapide si la sortie
d'air est équipée d'une douille à
connexion rapide.
38- FR
D24456
Download from Www.Somanuals.com. All Manuals Search And Download.
ENTRETIEN
Responsabilités du client
À chaque jour
ou après
Avant
chaque
utilisation
À chaque
année
Souvent
chaque
utilisation
Vérifier la soupape de sûreté
Vidanger le réservoir
ꢀ
ꢀ
ꢀꢀ(1)
Filtre à air
Soupapes d'admission et
d'échappementde la pompe du
compresseur d'air
ꢀ
1 - plus fréquemment dans des conditions poussiéreuses ou humides
1.
Avant de mettre en marche le
L'appareil
fonctionne
compresseur, tirez sur l'anneau de la
soupape de sûreté pour vous assurer que
la soupape fonctionne librement. Si la
soupape est coincée ou qu'elle ne bouge
pas librement, elle doit être remplacée
par une autre soupape du même type.
automatiquement en cycles lorsqu'il est
sous tension. En effectuant l'entretien,
vous pouvez être exposé aux sources
de tension, à l'air comprimé ou aux
pièces mobiles et subir ainsi des
blessures corporelles. Avant
d'entreprendre tout entretien ou
réparation, débranchez l'appareil et
purgez tout l'air pressurisé du réservoir.
Vidange du réservoir
1. Réglez le levier
marche/automatique/arrêt
"On/Auto/Off" à la position d'arrêt
"OFF".
2. Tirez le bouton du régulateur vers
l'extérieur et tournez-le dans le sens
des aiguilles d'une montre pour
régler la pression de sortie à zéro.
3. Enlevez l'outil pneumatique ou
l'accessoire.
4. Tirez l'anneau de la soupape de
sûreté pour permettre à l'air de
purger du réservoir jusqu'à ce que la
pression dans le réservoir se situe à
environ 20 lb/po2. Relâchez l'anneau
de la soupape de sûreté.
5. Vidangez l'eau du réservoir en
ouvrant le robinet de vidange.
(Tournez dans le sens contraire des
aiguilles d'une montre) situé en bas
du réservoir.
Afin d'assurer un rendement efficace et
une durée de vie utile plus longue du
compresseur d'air, un calendrier
d'entretien doit être préparé et observé.
Le calendrier d'entretien suivant a été
établi pour un appareil utilisé tous les
jours dans les conditions normales d'un
milieu de travail. Le calendrier devrait être
modifié, au besoin, pour s'adapter aux
conditions d'utilisation du compresseur
d'air. Ces modifications dépendent du
nombre d'heures d'utilisation et du milieu
de travail. Les compresseurs d'air utilisés
dans un milieu extrêmement malpropre ou
dans des conditions dures exigent des
vérifications d'entretien plus fréquentes.
REMARQUE : Consultez la section
"Utilisation" pour connaître l'emplacement
des commandes.
L'eau dans le
réservoir d'air
peut condenser. Si l'eau n'est pas
vidangée, cela risque de corroder et
d'affaiblir le réservoir d'air, produisant
ainsi un risque de rupture du réservoir
d'air.
Vérification de la soupape de sûreté
Si la soupape
de sûreté ne
fonctionne pas correctement, une
surpression pourrait avoir lieu et causer une
rupture ou une explosion du réservoir à air.
39- FR
D24456
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Une fois la vidange de l'eau terminée,
fermez le robinet de vidange (tournez
dans le sens des aiguilles d'une
montre). Le compresseur d'air peut
maintenant être rangé.
REMARQUE : Si le robinet de vidange est
engorgé, libérez tout l'air pressurisé. Le
robinet de vidange peut alors être enlevé,
nettoyé et réinstallé.
Soupapes d'admission et
d'échappement de la pompe du
compresseur d'air
Demandez à un technicien de service
qualifié de vérifier annuellement les
soupapes d'admission et d'échappement
de la pompe du compresseur d'air.
Moteur
Le moteur est équipé d'un dispositif de
protection contre les surcharges
thermiques avec rétablissement
automatique. Si le moteur surchauffe pour
quelque raison que ce soit, le dispositif de
protection contre les surcharges arrêtera
le moteur. Laissez refroidir le moteur. Le
compresseur redémarrera
Filtre à air - Inspection et
remplacement
Surfaces
chaudes.
Risque de brûlures. Les têtes du
compresseur sont exposées lorsque le filtre
du compresseur est retiré. Avant de
commencer, laissez refroidir le
compresseur.
automatiquement une fois que le moteur
est bien refroidi.
Si le dispositif de protection contre les
surcharges arrête souvent le moteur,
vérifiez s'il y a un problème de tension.
Une tension trop basse peut également
être la cause des problèmes suivants :
Le filtre à air doit être
maintenu propre en
tout temps. Ne pas utiliser le compresseur
d’air sans le filtre à air.
Un filtre à air malpropre ne permettra pas au
compresseur d’air de fonctionner à sa pleine
capacité. Avant d’utiliser la pompe du
compresseur d’air, vérifier le filtre à air pour
vous assurer qu’il est propre et bien en place.
1. Le moteur n'atteint pas la vitesse ni
la puissance maximales.
2. Les fusibles sautent lors de la mise
en marche du moteur ; les lumières
s'affaiblissent et demeurent faibles
une fois que le moteur est démarré et
lorsqu'il tourne.
S’il est malpropre, le remplacer par un nouveau
filtre. Sur certains modèles le filtre à air peut
être enlevé en utilisant une pince à becs
pointus ou un tournevis. Tirer le vieux filtre
pour le retirer et nettoyer soigneusement le
réceptacle du filtre. Insérer un nouveau filtre à
air.
40- FR
D24456
Download from Www.Somanuals.com. All Manuals Search And Download.
ENTRETIEN ET RÉGLAGES
Le compresseur
4. À l'aide d'une clé réglable, desserrez
l'écrou du tube de décharge de
pression au niveau du réservoir d'air
et du manostat. Éloignez
d'air fonctionne
automatiquement lorsqu'il est sous tension.
En effectuant l'entretien, vous pourriez être
exposé aux sources de tension, à de l'air
comprimé ou aux pièces en mouvement et
subir ainsi des blessures corporelles. Avant
de procéder à tout entretien ou réparation,
débranchez le compresseur et purgez tout
l'air pressurisé.
soigneusement le tube de décharge
de pression de la soupape de
retenue.
5. À l'aide d'une clé ouverte de 7/8 po
(22 mm), dévissez la soupape de
retenue (en tournant dans le sens
contraire des aiguilles d'une montre).
Notez l'orientation pour l'assemblage
plus tard.
6. À l'aide d'un tournevis, poussez
doucement le disque de soupape
vers le haut et vers le bas.
TOUS LES SERVICES D'ENTRETIEN NE
FIGURANT PAS ICI DOIVENT ÊTRE
EXÉCUTÉS PAR UN TECHNICIEN
QUALIFIÉ.
REMARQUE : Le disque de soupape
devrait se déplacer librement vers le
haut et vers le bas sur un ressort qui
retient le disque de soupape en
position fermée. Si cela n'est pas le
cas, la soupape de retenue doit être
nettoyée ou remplacée.
Avant de
procéder à l'entretien :
•
Débranchez le compresseur d'air de
la source d'alimentation électrique.
•
•
Purgez l'air pressurisé du réservoir.
Attendez jusqu'à ce que le
compresseur d'air soit refroidi.
Remplacement ou nettoyage de la
soupape de retenue
Tournevis
1. Déchargez tout l'air pressurisé du
réservoir d'air. Voir la partie intitulée
"Vidange du réservoir" de la section
sur l'entretien.
En position
ouverte, rien
n'est visible
2. Débranchez le compresseur d'air.
En position fermée, le
disque est visible
3. À l'aide d'une clé réglable, desserrez
l'écrou du tube de sortie au niveau
du réservoir d'air et de la pompe.
Éloignez soigneusement le tube de
sortie de la soupape de retenue.
7. Nettoyez ou remplacez la soupape
de retenue. Utilisez un solvant, tel
qu'un décapant de peinture ou de
verni, pour nettoyer la soupape de
retenue.
8. Appliquez un produit d'étanchéité sur
les filets de la soupape de retenue.
Réinstaller la soupape (en tournant
dans le sens des aiguilles d'une
montre).
Tube de décharge
de pression
Écrou
Tube de
sortie
9. Remettez en place le tube de
décharge de pression et serrez les
écrous.
10. Remettez en place le tube de sortie
Soupape
de
retenue
et serrez les écrous.
Écrou
11. Effectuez la procédure de rodage.
Voir la partie intitulée "Procédures de
rodage" de la section sur l'utilisation.
41- FR
Download from Www.Somanuals.com. All Manuals Search And Download.
D24456
RANGEMENT
L'eau dans le
réservoir
d'air peut condenser. Si le réservoir
n'est pas vidangé, l'eau corrodera et
affaiblira les parois du réservoir d'air,
causant ainsi un risque d'éclatement du
réservoir.
Avant de ranger le compresseur d'air,
effectuez les étapes
suivantes :
1. Revoyez la section intitulée
"Entretien" des pages précédentes et
exécutez l'entretien requis.
2. Placez le levier "On/Auto/Off" à la
7. Une fois la vidange de l'eau terminée,
position "OFF".
fermez le robinet de vidange.
3. Tournez le régulateur dans le sens
contraire des aiguilles d'une montre
et réglez la pression de sortie à zéro.
REMARQUE : Si le robinet de vidange
est engorgé, libérez tout l'air pressurisé.
Le robinet de vidange peut alors être
enlevé, nettoyé et réinstallé.
4. Débranchez l'outil pneumatique ou
l'accessoire.
8. Protégez le cordon électrique et le
boyau d'air contre tout dommage (de
façon à ce qu'ils ne soient pas
coincés ou écrasés). Enroulez-les,
sans contrainte, autour de la poignée
du compresseur d'air (le cas
échéant).
5. Tirez l'anneau de la soupape de
sûreté pour purger l'air du réservoir
jusqu'à ce que la pression dans le
réservoir soit d'environ 20 lb/po2.
Relâchez l'anneau de la soupape de
sûreté.
Rangez le compresseur d'air dans un
endroit propre et sec.
6. Vidangez l'eau du réservoir d'air en
ouvrant le robinet de vidange situé en
bas du réservoir.
42- FR
D24456
Download from Www.Somanuals.com. All Manuals Search And Download.
DÉPANNAGE
Le fait d'effectuer des réparations vous expose à des sources
de tension, d'air comprimé ou à des pièces en mouvement.
Des blessures pourraient ainsi survenir. Avant de faire toute réparation, débranchez la
source d'alimentation du compresseur et laissez s'échapper toute la pression d'air.
CORRECTIF
CAUSE
PROBLÈME
Pression excessive
Le pressostat ne met pas le
Mettez la manette On/Auto/Off
dans le réservoir - moteur hors tension lorsque le
dans la position d'arrêt " Off ".
compresseur atteint un niveau
de pression excessif.
la soupape de
sûreté saute.
Si l'appareil ne s'arrête pas,
adressez-vous à un technicien
qualifié.
La limite du pressostat est trop
élevée.
Adressez-vous à un technicien
qualifié.
L'air fuit aux
points de raccord.
Les raccords des tubes ne sont
pas assez serrés.
Resserrez les raccords où vous
entendez l'air s'échapper. Vérifiez
les raccords à l'aide d'une solution
d'eau savonneuse. ÉVITEZ DE
TROP SERRER.
Le siège du clapet est
endommagé.
Une soupape de retenue
L'air fuit au clapet
ou à l'intérieur de
celui-ci.
défectueuse entraîne une fuite d'air
constante au niveau de la soupape
de décharge de pression lorsque
l'air dans le réservoir est sous
pression et que le compresseur est
arrêté. Remplacez la soupape de
retenue. Consultez la partie intitulée
"Remplacement ou nettoyage de la
soupape de retenue" de la section
sur l'entretien et réglages.
Soupape de détente du
pressostat défectueuse.
Adressez-vous à un technicien
qualifié.
L'air fuit à la
soupape de
détente du
pressostat.
Réservoir d'air défectueux.
Le réservoir doit être remplacé.
Ne réparez pas la fuite.
L'air fuit du
réservoir ou des
joints du réservoir.
Évitez de percer, de souder ou
de modifier le réservoir d'air
de quelque façon. Celui-ci
risquerait de rompre ou
d'exploser.
Joint fuyard.
Adressez-vous à un technicien
qualifié.
Fuite d'air entre la
tête et la plaque
de la soupape.
43- FR
Download from Www.Somanuals.com. All Manuals Search And Download.
D24456
CORRECTIF
CAUSE
PROBLÈME
S'il y a une chute excessive de
pression lors de l'utilisation d'un
accessoire, ajustez le régulateur
en suivant les instructions dans la
section intitulée "Fonctionnement".
Il est normal qu'une
certaine chute de pression
ait lieu.
Le relevé de
pression indiqué
sur le manomètre
réglé (si fourni)
tombe si un
REMARQUE : Réglez la pression
régularisée dans des conditions de
débit (pendant que l'accessoire est
utilisé).
accessoire est
utilisé.
Faites fonctionner manuellement la
soupape de sûreté en tirant sur
l'anneau. Si la soupape fuit toujours,
elle doit être remplacée.
Fuite d'air au
niveau de la
soupape de sûreté.
Défectuosité possible dans la
soupape de sûreté.
Usage d'air prolongé ou
excessif.
Le compresseur n'est pas
assez puissant pour les
exigences en air.
Réduisez l'usage d'air.
Le compresseur
n'émet pas assez
d'air pour faire
fonctionner les
accessoires.
Vérifiez l'exigence en air des
accessoires. Si elle est supérieure au
pi3/mn/à la pression fournie par votre
compresseur, vous devrez vous munir
d'un compresseur plus puissant.
Trou dans le boyau.
Vérifiez et remplacez-le au besoin.
Retirez et nettoyez-le ou remplacez-le.
Resserrez les raccords.
Clapet obstrué.
Fuite d'air.
Nettoyez ou remplacez le filtre de la
prise d'air. N'utilisez pas le
compresseur une fois le filtre
enlevé. Consultez le paragraphe
"Filtre d'air" de la section
Filtre de la prise d'air obstrué.
"Entretien".Desserrez l'écrou à
oreilles et resserrez-le ensuite
jusqu'à ce qu'il touche la rondelle
en ajoutant ensuite un tour
supplémentaire.
Entrée d'air
restreinte.
Nettoyez ou remplacez-le. Voir le
paragraphe " Filtre à air " de la
section " Entretien ".
Filtre à air encrassé.
Régulateur endommagé.
De l'air fuit
Adressez-vous à un technicien qualifié.
constamment de
la poignée du
régulateur.
Le régulateur ne
réussit pas à
fermer
Régulateur endommagé.
Adressez-vous à un technicien qualifié.
complètement la
sortie d'air.
44- FR
D24456
Download from Www.Somanuals.com. All Manuals Search And Download.
CAUSE
PROBLÈME
CORRECTIF
Laissez le moteur refroidir et le
protecteur de surcharge se
réenclenchera.
Le protecteur contre la surcharge
du moteur a été désenclenché.
Le moteur ne
fonctionne pas.
Le moteur démarrera
La pression du réservoir excède
la limite établie du pressostat.
automatiquement une fois la pression
du réservoir tombée sous la limite
établie du pressostat.
Retirez et nettoyez-le ou remplacez-le.
Clapet coincé en position ouverte.
Connexions électriques lâches.
Vérifiez les connexions des fils dans
le pressostat et dans la boîte de
raccordement.
Possibilité de défectuosité du
moteur ou du condensateur de
démarrage.
Faites appel à un technicien qualifié.
Faites appel à un technicien qualifié.
N'utilisez pas le compresseur dans le
secteur d'une pulvérisation de peinture.
Voir l'avertissement au sujet des vapeurs
inflammables.
Jet de peinture sur les pièces
internes du moteur.
La soupape de détente du
pressostat n'a pas relâché la
pression des têtes.
Libérez la pression du boyau en mettant
sur le levier du pressostat en position
d'arrêt (" Off "). Si la soupape ne s'ouvre
pas de nouveau, remplacez-la
Fusible sauté, disjoncteur
déclenché.
1.
Vérifiez le coffret à fusibles pour y
trouver des fusibles sautés et, le
cas échéant, remplacez-les.
Réenclenchez le disjoncteur.
N'utilisez pas de fusible ou de
disjoncteur dont le régime excède
le régime précisé pour ce circuit
de dérivation particulier.
2.
3.
Vérifiez que vous utilisez des
fusibles appropriés. Des fusibles
à retardement sont nécessaires.
Assurez-vous de l'absence de
toute situation de basse tension
et(ou) assurez-vous d'utiliser une
rallonge convenable.
4.
Débranchez tout autre appareil
électrique du circuit ou utilisez le
compresseur sur son propre
circuit de dérivation.
Bruit de
cliquetis.
Problème possible de la soupape
de sûreté.
Opérez la soupape de sûreté
manuellement en tirant sur l'anneau.
Si la soupape fuit toujours, remplacez-la.
Clapet défectueux.
Retirez et nettoyez-le ou remplacez-le.
45- FR
D24456
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES / REMARQUES
50- FR
D24456
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES / REMARQUES
51- FR
D24456
Download from Www.Somanuals.com. All Manuals Search And Download.
Get it fixed, at your home or ours!
Just Call:
1-800-4-MY-HOME®
(1-800-469-4663)
24 hours a day, 7 days a week
For the repair of major brand appliances in your own home…
no matter who made it, no matter who sold it!
For your nearest Sears Parts and Service location,
to bring in products like vacuums, lawn equipment and electronics.
For Sears Parts & Service, to order the replacement parts,
accessories and owner’s manuals that you need to do-it-yourself.
To purchase or inquire about a Sears Maintenance Agreement, call:
1-800-361-6665
9 a.m. – 8 p.m. EST, Mon. – Fri., 4 p.m. Sat.
Pour service en français:
1-800-LE-FOYERMC
(1-800-533-6937)
HomeCentral®
TM Trademarks of Sears, Roebuck and Co. used under license by Sears Canada
®
/
MC
/
MD Marque de commerce / déposée de Sears, Roebuck and Co. utilisée en vertu d’une licence de Sears Canada
© Sears
Download from Www.Somanuals.com. All Manuals Search And Download.
|