DESCRIPTION  
Type  
The IA Series is an energy efficient family of light duty industrials that  
feature premium performance and durability. The series incorporates sturdy  
embossed reflectors that precisely direct and effectively control light. The IA  
Series can be installed using various mounting methods and numerous  
options and accessories are available. The series is available with both  
Apertured (IA) and Closed Top (IC) reflector combinations.  
Catalog #  
Project  
Date  
Comments  
Prepared by  
The IA Series can be utilized in simple task and area lighting and industrial  
applications.  
SPECIFICATION FEATURES  
A ... Construction  
B ... Electrical*  
D ... Reflectors  
Channel is code gauge prime cold  
rolled steel. Numerous KOs for  
ease of installation. End plate  
quickly connects to channel  
connector for continuous row  
alignment. Lampholder mounting  
brackets are easily inserted with  
snap-in action.  
Ballast are CBM/ETL Class "P" and  
positively secured by mounting  
bolts. Spring loaded lampholders.  
UL/CUL listed. Suitable for damp  
locations.  
Die formed prime steel, code  
gauge. Formed edges for added  
strength. All reflectors 4' sections.  
12" width Reflectors secured with  
quarter-turn fasteners. Baked white  
enamel. Standard with 8% uplight  
(IA). Closed top reflector (IC).  
Optional industrial fixtures are  
available incorporating silver  
technology enhancements.  
(SilverLining)  
C ... Finish  
Multistage iron phosphate  
pretreatment ensures maximum  
bonding and rust inhibitor.  
Lighting grade, baked white  
enamel finish.  
IA, IC  
248  
296  
C
B
A
D
296T8  
4' or 8' INDUSTRIAL  
2 LAMP  
4-5/8"  
[117mm]  
SLIMLINE  
Light Duty Industrial  
12"  
[305mm]  
LAMP CONFIGURATIONS  
MOUNTING DATA  
X
15/64" [6mm] K.O. (4)  
11/16" [17mm] x 1" K.O. (2)  
7/8" [22mm] K.O. (4)  
4-5/8" [117mm]  
7/32" [6mm] x 3/8" [10mm] K.O. (4)  
X=4-1/4"  
Y
[108mm]  
1-3/4" [44mm] x 3-1/4" [83mm] K.O. (1)  
Ground Screw Bump  
3/16"  
[5mm]  
12"  
[305mm]  
Y=2-5/8"  
[67mm]  
4-1/4"  
[108mm]  
1-1/8"  
[29mm]  
16-1/2" [419mm]  
41-1/2" [1054mm]  
43-7/8" [1114mm]  
48" [1219mm]  
15/64" [6mm] K.O. (4)  
11/16" [17mm] x 1 K.O. (2)  
7/8" [22mm] K.O. (5)  
1-3/4" [17mm] x 3-1/4" K.O. (1)  
Ground Screw Bump  
3/16"  
[5mm]  
Ceiling Stand-Off  
Embossments  
11/16" [17mm] K.O. (2)  
4-1/4"  
[108mm]  
1-1/8"  
[29mm]  
48" [1219mm]  
81" [2057mm]  
89-1/2" [2273mm]  
91-7/8" [2334mm]  
96" [2438mm]  
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING  
TO LOCAL, STATE OR FEDERAL LAWS  
Safe and convenient means of  
disconnecting power  
Specifications and Dimensions subject to change without notice.  
ADF020759  
09/17/2008 4:57:26 PM  
Consult your representative for additional options and finishes.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IA, IC  
PHOTOMETRICS  
Coefficients of Utilization  
Effective floor cavity reflectance  
Candela  
45o  
2668  
2619  
2549  
2441  
2315  
2171  
1936  
1429  
473  
29  
Across  
2668  
2675  
2640  
2640  
2619  
2535  
2199  
1359  
259  
22  
20%  
50%  
Angle  
0
Along II  
rc  
rw  
RCR  
0
80%  
70%  
30%  
10%  
0%  
0
2668  
2647  
2521  
2325  
2052  
1716  
1303  
847  
336  
8
70 50 30 10  
70 50 30 10  
50 30 10  
50 30 10  
50 30 10  
10  
20  
105 105 105 105  
95 90 86 83  
85 78 71 65  
77 67 59 53  
70 59 50 44  
64 52 44 37  
59 46 38 32  
54 42 34 28  
51 38 30 25  
47 35 27 22  
44 32 25 20  
102102 102 102  
92 88 84 81  
82 75 69 64  
74 65 58 52  
68 57 49 43  
62 51 43 37  
57 45 37 32  
52 41 33 28  
49 37 30 24  
45 34 27 22  
43 31 24 20  
96 96 96  
83 80 77  
71 66 62  
62 56 51  
54 47 42  
48 41 36  
43 36 31  
39 32 27  
35 29 24  
32 26 21  
30 24 19  
90 90 90  
78 76 73  
67 63 59  
58 53 49  
51 46 41  
46 40 35  
41 35 30  
37 31 26  
34 28 23  
31 25 21  
29 23 19  
86 86 86  
74 72 70  
64 60 57  
55 51 47  
49 44 40  
43 38 34  
39 34 29  
35 30 26  
32 27 23  
30 24 20  
27 22 18  
83  
68  
55  
45  
37  
32  
27  
24  
21  
19  
17  
30  
1
40  
2
50  
||  
3
60  
4
70  
5
80  
6
90  
7
3
160  
296  
220  
113  
26  
174  
336  
438  
284  
139  
27  
100  
110  
120  
130  
140  
150  
160  
170  
180  
IA-296T8  
Energy Saving  
Ballast  
8
3
9
5
10  
6
F96T8/SPX35 Lamps  
5950 Lumens  
8
Zonal Lumen Summary  
9
11  
8
8
11  
Spacing criterion:  
(II) 1.3 x mounting  
height, ( ) 1.5 x  
mounting height  
Zone  
0-30  
Lumens  
2152  
3653  
7182  
9903  
735  
%Lamp  
18.1  
30.7  
60.3  
83.2  
6.2  
%Fixture  
20.2  
8
6
8
7
7
7
0-40  
34.3  
0-60  
67.5  
0-90  
93.1  
Efficiency 89.4%  
90-180  
0-180  
6.9  
Test Report:  
IA296T8.IES  
10637  
89.4  
100.0  
LER = FI-84  
Yearly Cost of 1000  
lumens, 3000 hrs at  
.08 KWH = $2.86  
ORDERING INFORMATION  
Sample Number: IA-296T8-120V-EB81-U  
1
2
Tandem  
= 4' Length  
SilverLining  
Number of Lamps  
Ballast Type  
Options  
=Silver-Lining  
Housing and  
Ballast Cover  
2 Lamps (Not Included)  
=T12 Magnetic Energy  
Saving  
=Higher Ballast Factor > 1.13.  
/PLUS  
Blank  
SS  
LE3  
Total Harmonic Distortion < 20%  
= 8' Length  
8T  
=Electronic Instant Start  
=Radio Interference Suppressor  
=Cord & Plug  
Wattage  
EB  
ER  
RIF1  
=40W T12 SL (48")  
=T8 Electronic Program  
Rapid Start. Total  
Harmonic Distortion < 10%  
48  
6-3/18 SJT-C&P-L515P  
Series  
(120V)  
=75W T12 SL (72")  
=Apertured Reflector  
96  
IA  
=Cord & Plug  
(277V)  
6-3/18 SJT-C&P-L715P  
=59W T8 SL (96")  
=Closed Top Reflector  
96T8  
IC  
=Extra Wide Channel  
Reference STW  
ICW  
Lamp Size  
=Tandem In Line Wiring Option  
(Consult TILW Option Catalog  
Page)  
TILW  
2
Voltage  
=T12  
=T8  
2
8
Series with  
=120 Volt  
=277 Volt  
=347 Volt  
=Universal Voltage3  
120-277  
120V  
277V  
347V  
UNV  
Symmetric Reflector  
=Porlux Finish  
POX  
=Plug-In Option  
PI/CPI  
Number of  
Ballasts  
1 Ballast  
=
1
2
Packaging  
=2 Ballast  
Options  
=Unit Pack  
U
=Single Element Fuse  
GL  
=4 Bulk Packing  
4B  
=Double Element Fuse  
GM  
=EM Installed  
Emergency  
SHIPPING INFORMATION  
Catalog No. Wt.  
Notes:  
1
2
3
Silver lining not available on fixtures with HO.  
Products also available in non-US voltage and frequencies for international markets  
Not available when specifying emergencies, voltage must be specific  
IA-248  
IA-296T8  
16 lbs.  
30 lbs.  
ACCESSORIES (Order Separately)  
A1B/Spacer-U=Spacer 1-1/2" to 2-1/2" from ceiling  
(Use 2 per fixture)  
GRP-SS=Gripper Hanger (Use 2 per fixture)  
SCF=Fixed Stem Set (Specify Length)  
SCS=Swivel Stem Set (Specify Length)  
SCA=Adjustable 48" Stem Set  
AYC-Chain/Set-U =Chain Hanger Set (Use 1 set per fixture)  
2
WG/IC-4FT-U =Wire Guard  
CLC=Special Connector  
(Additional Accessories Available. See Options and Accessories Section).  
Specifications and Dimensions subject to change without notice.  
Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801  
ADF020759  
09/17/2008 4:57:26 PM  
Download from Www.Somanuals.com. All Manuals Search And Download.  

CMA Dishmachines Dishwasher CMA 66 User Manual
Coleman Stove 425G User Manual
Continental Electric Kitchen Grill CE23791 User Manual
Cooper Lighting Indoor Furnishings Westwood 913 User Manual
Cornelius Beverage Dispenser ED DF User Manual
Craftsman Trimmer 900 74522 User Manual
Crate Amplifiers Musical Instrument Amplifier GFX 1200H User Manual
Crown Audio Stereo Amplifier SST MX User Manual
GE Monogram Range ZX2YSS User Manual
Generac Power Systems Switch 004635 2 User Manual