Cisco Systems Life Jacket SG200 User Manual

ADMINISTRATION  
GUIDE  
Cisco Small Business  
SG200 Series 8-port Smart Switches  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
Getting Started  
This chapter provides an introduction to the web-based switch configuration  
utility and includes the following topics:  
Starting the Web-Based Switch Configuration Utility  
This section describes how to navigate the web-based switch configuration utility.  
Browsers have the following restrictions:  
If you are using Internet Explorer 8, open a browser window and configure  
the following settings:  
Click Tools > Internet Options and then select the Security tab. Select  
Local Intranet and click Sites. Click Advanced and then click Add. Add the  
intranet address of the switch (http://<ip-address>) to the local intranet  
zone. The IP address can also be specified as the subnet IP address, so that  
all addresses in the subnet are added to the local intranet zone.  
If you are using Internet Explorer 6, you cannot directly use an IPv6 address  
to access the switch. You can, however, use the Domain Name System  
(DNS) server to create a domain name that contains the IPv6 address, and  
then use that domain name in the address bar in place of the IPv6 address.  
If you have multiple IPv6 interfaces on your management station, use the  
IPv6 global address instead of IPv6 link local address to access the switch  
from your browser.  
Screen resolutions at 800x600 or lower in Internet Explorer browsers and  
Firefox 3.6 are not supported by the web-based switch configuration utility.  
Cisco Small Business SG200 Series 8-port Smart Switch  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Getting Started  
Starting the Web-Based Switch Configuration Utility  
1
Launching the Utility  
To open the web-based switch configuration utility:  
STEP 1 Open a web browser.  
STEP 2 Enter the IP address of the switch that you are configuring in the address bar on  
the browser, and then press Enter. (The factory default IP address is  
192.168.1.254.) The Log In page opens.  
Logging In  
To log in to the web-based switch configuration utility:  
STEP 1 Enter the username and password. The factory default user name is cisco and the  
default password is cisco.  
Note: When the switch boots with the factory default configuration, the web-  
based switch configuration utility appears in the default language. After you log in,  
you can download additional languages by using the Upgrade/Backup Firmware/  
Language page.  
STEP 2 If this is the first time that you logged on with the default user name (cisco) and the  
default password (cisco) or your password has expired, the Change Admin  
Password page opens. Enter the new password, confirm it, click Apply, and then  
click Close. (The characters ', ", %, and ? are not supported.) The new password is  
saved.  
NOTE Password complexity is enabled by default and the new password must comply to  
the default password complexity rule defined by the password strength. (See  
Adding a User for more information.) The password strength check can be  
temporarily disabled by selecting the Disable Password Strength Enforcement  
option.  
STEP 3 Click Login.  
When the login attempt is successful, the Getting Started page opens.  
If you entered an incorrect user name or password, an error message is displayed  
and the Log In page remains displayed on the screen.  
NOTE When logging in by using HTTP or HTML, if you are provided an option to choose  
from more than one network port, select the lowest number port.  
Cisco Small Business SG200 Series 8-port Smart Switch  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Getting Started  
Starting the Web-Based Switch Configuration Utility  
1
Select Don’t show this page on startup to prevent the Getting Started page from  
being displayed each time that you logon to the system. If you select this option,  
the System Summary page is opened instead of the Getting Started page.  
Logging Out  
By default, the application automatically logs you out after 10 minutes of inactivity.  
See Configuring the Idle Session Timeouts for instructions on changing the  
default timeout period.  
To log out at any time, click Logout in the top right corner of any page.  
!
CAUTION Unless the Running Configuration is copied to the Startup Configuration file type,  
all changes made since the last time the file type was saved are lost if the switch is  
rebooted. We recommend that you save the Running Configuration to the Startup  
Configuration file type before logging off to preserve any changes you made  
during this session.  
A red X icon displayed to the left of the Save button indicates that Running  
Configuration changes have been made that have not yet been saved to the Startup  
Configuration file type.  
When you click Save, the Download/Backup Configuration/Log page displays  
Running Configuration by copying it to the Startup Configuration file type. After this  
save, the red X icon and the Save button no longer display.  
Cisco Small Business SG200 Series 8-port Smart Switch  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Getting Started  
Quick Start Device Configuration  
1
Quick Start Device Configuration  
To simplify device configuration through quick navigation, the Getting Started  
page provides links to the most commonly-used pages.  
Links on the Getting Started Page  
Category  
Link Name (on the Page)  
Linked Page  
Initial Setup Change Device IP Address IPv4 Interface  
Create VLAN  
Create VLAN  
Port Settings  
System Summary  
Interface  
Configure Port Settings  
System Summary  
Port Statistics  
Device  
Status  
RMON Statistics  
RMON Statistics  
RAM Memory  
User Accounts  
View Log  
Quick  
Change Device Password  
Upgrade Device Software  
Access  
Upgrade/Backup Firmware/  
Language  
Backup Device  
Configuration  
Download/Backup Configuration/  
Log  
Configure QoS  
QoS Properties  
Port Mirroring  
Configure Port Mirroring  
Cisco Small Business SG200 Series 8-port Smart Switch  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Getting Started  
Window Navigation  
1
Window Navigation  
This section describes the features of the web-based switch configuration utility.  
Application Header  
The Application Header is displayed on every page. It provides the following  
buttons:  
Buttons  
Name  
Description  
The Syslog Alert Status button (red circle with an X) is  
displayed when a new Syslog message, above the critical  
severity level, is logged. Click to open the Status and  
Statistics > View Log > RAM Memory Log page. After  
you access this page, the Syslog Alert Status button is no  
longer displayed.  
A red X icon, displayed to the left of the Save button,  
indicates that configuration changes have been made and  
have not yet been saved to the Startup Configuration file.  
When you click this button, the Download/Backup  
Configuration/Log page displays. Save the Running  
Configuration by copying it to the Startup Configuration  
file type. After you click Apply to save this file, the red X  
icon and the Save button are no longer displayed. When  
the switch is rebooted, it copies the Startup Configuration  
file type to the Running Configuration and sets the switch  
parameters according to the data in the Running  
Configuration.  
User  
The name of the user logged on to the switch. The default  
user name is cisco.  
Language Menu  
Select a language or load a new language file into the  
device. If the language required is displayed in the menu,  
select it. If not, select Download Language. For more  
information about adding a new language, refer to the  
Upgrade/Backup Firmware/Language page.  
Cisco Small Business SG200 Series 8-port Smart Switch  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Getting Started  
Window Navigation  
1
Buttons (Continued)  
Name  
Description  
Log Out  
Click to log out of the web-based switch configuration  
utility.  
About  
Help  
Click to display the switch type and switch version  
number.  
Click to display the online help.  
Other Resources  
You can use the following links on the Getting Started page for additional  
information and assistance with using your switch:  
Support—Displays the support web page for Cisco Small Business  
Managed Switches.  
Forums—Displays the web page for the Cisco Small Business Support  
Community.  
Cisco Small Business SG200 Series 8-port Smart Switch  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Getting Started  
Window Navigation  
1
Navigation Window  
A navigation window is located on the left side of each page. Click a top-level  
category to display links to related pages. Links that are preceded by an arrow are  
subcategories that expand to display the related page links.  
Management Buttons  
The following table describes the commonly-used buttons that appear on various  
pages in the system.  
Management Buttons  
Name  
Description  
Depending on the number of pages and the currently  
displayed page, use these features to navigate through  
the pages of the table. Click |< to go to the first page,  
click < to go to the previous page, click > to go to the  
next page, and click >| to go to the last page. Use the  
Page <number> of <number> drop-down list to choose  
a particular page.  
Cisco Small Business SG200 Series 8-port Smart Switch  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Getting Started  
Window Navigation  
1
Management Buttons (Continued)  
Name Description  
Select the number of table entries to display on each  
page.  
Indicates a mandatory field.  
Add  
Click to display the related Add page and add an entry  
to a table. Enter the information and click Apply. Click  
Close to return to the main page.  
Note: Your changes are applied to the running  
configuration only. If the switch is rebooted, the running  
configuration is lost. To save your changes to the startup  
configuration, click Save. For more information, see  
Apply  
Click to apply the changes that you entered on the  
selected page.  
Note: Your changes are applied to the running  
configuration only. If the switch is rebooted, the running  
configuration is lost. To save your changes to the startup  
configuration, click Save. For more information, see  
Cancel  
Click to “undo” the changes that you made on the page  
and to reset the values to the previously applied entries.  
Clear All Interfaces Click to clear the statistic counters for all interfaces.  
Counters  
Clear Interface  
Counters  
Click to clear the statistic counters for the selected  
interface.  
Clear Logs  
Clear Table  
Close  
Click to clear the log files.  
Click to clear the table entries.  
Click to return to the main page. If there are changes that  
were not applied to the Running Configuration, a  
message is displayed.  
Cisco Small Business SG200 Series 8-port Smart Switch  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Getting Started  
Window Navigation  
1
Management Buttons (Continued)  
Name  
Description  
Copy Settings  
A table typically contains one or more entries containing  
configuration settings. Instead of modifying each entry  
individually, it is possible to modify one entry and then  
copy it to multiple entries, as described below:  
Select the entry to be copied. Click Copy  
Settings.  
Enter the destination entry numbers.  
Click Apply to save the changes to the Running  
Configuration.  
Click Close to return to the main page.  
Delete  
Details  
Edit  
Select the entry in the table to be deleted and click  
Delete. The entry is deleted.  
Click to display details associated with the entry  
selected on the main page.  
Select an entry and click Edit to open it for editing. The  
Edit page opens, and the entry can be modified.  
Click Apply to save the changes to the Running  
Configuration. (Note that there is no message to  
confirm that the parameters have been saved to  
the Running Configuration. This is normal  
behavior.)  
Click Close to return to the main page.  
Test  
Click Test to perform related tests.  
Clear Filter  
Click Clear Filter to redisplay data on a page with the  
default criteria.  
Go  
Click Go to filter the data displaying on a page using the  
selected criteria.  
Cisco Small Business SG200 Series 8-port Smart Switch  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Getting Started  
Window Navigation  
1
Management Buttons (Continued)  
Name  
Description  
Sort buttons  
If the This table is sortable message appears below a  
table, each column heading is a sort button. Click a  
column heading to sort the records in ascending order,  
based on the contents of the selected column. After the  
sort is applied, an arrow appears in the column heading.  
You can click this arrow to reverse the sort order.  
Cisco Small Business SG200 Series 8-port Smart Switch  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2
Viewing Statistics  
This chapter describes how to display switch statistics.  
It contains the following topics.  
System Summary  
The System Summary page displays basic information such as the hardware  
model description, software version, language packs, and system up time.  
Displaying the System Summary  
To view system information, click Status and Statistics > System Summary in the  
navigation window. Or, click System Summary under Device Status on the  
Getting Started page.  
The System Summary page displays the following information:  
System Description—A description of the system.  
System Location—Physical location of the switch. Click Edit to display the  
System Settings page and enter this value. (The characters ', ", %, and ? are  
not supported.)  
Cisco Small Business SG200 Series 8-port Smart Switch  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Viewing Statistics  
System Summary  
2
System Contact—Name of a contact person. Click Edit to display the  
System Settings page and enter this value. (The characters ', ", %, and ? are  
not supported.)  
Hostname—Name of the switch. Click Edit to display the System Settings  
page and enter this value. By default, the switch hostname is composed of  
the word switch concatenated with the three least significant bytes of the  
switch MAC address (the six furthest right hexadecimal digits).  
System Object ID—The base object ID for the system’s management  
information base (MIB).  
System Uptime—Time that has elapsed since the last reboot.  
Current Time—Current system time.  
Base MAC Address—Switch MAC address.  
Hardware and Firmware Version Information  
The following hardware and software information displays for the switch:  
Serial Number—Serial number of the switch.  
PID VID—Part number and version ID.  
Boot Version—Version of the boot code.  
Maximum Available Power (W)—(PoE switches only) Maximum available  
power that can be delivered by the PoE ports.  
Threshold Power—(PoE switches only) The amount of power that must be  
available for delivery in order for the port to be powered up.  
Consumed Power—(PoE switches only) Power currently being delivered to  
the PoE devices connected to the switch.  
Firmware Version—Firmware version number of the active image.  
Firmware MD5 Checksum—MD5 checksum of the active image.  
Boot MD5 Checksum—MD5 checksum of the boot code.  
You can view settings for each switch port. To display the Port Settings page, click  
the port.  
Cisco Small Business SG200 Series 8-port Smart Switch  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Viewing Statistics  
System Summary  
2
Language Pack Table  
This table displays information about the languages available on the switch. A  
language can be selected by the administrator when logging into the configuration  
utility.  
English is the default language and it is built into the software. You can use the  
Upgrade/Backup Firmware/Language page to download additional language  
packs. Language files are available from the Cisco firmware download page.  
The Language Pack Table displays the following information for each available  
language:  
Language—Language name.  
Locale—Internet Engineering Task Force (IETF) locale code that identifies  
the language and the country or region.  
Version—Language file version.  
MD5 Checksum128-bit hash code used to check file integrity.  
File Size—The file size in KB.  
File Type—Indicates one of the following values:  
-
Built-In—Default language provided within the software and therefore  
cannot be downloaded as a separate file.  
-
External—A language file that has been downloaded to the switch and  
can be selected at login.  
Default—Displays Yes to indicate that the web-based switch configuration  
utility login page will display in this language whenever the switch is  
rebooted.  
Status—Displays Active or Inactive. At log-in, the user can choose a  
language. The selected language is the Active language.  
Number of Users—The number of management users currently logged in  
and using this language.  
TCP and UDP Services  
This table lists the information for each service that uses TCP or UDP:  
Service Name—The commonly–used name of the service, if available, such  
as HTTP.  
Type—The transport protocol used for this service (TCP or UDP).  
Cisco Small Business SG200 Series 8-port Smart Switch  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Viewing Statistics  
System Summary  
2
Port—The Internet Assigned Numbers Authority (IANA) port number for the  
service.  
IP Address—The IP address, if any, of a remote device that is connected to  
this service on the switch.  
Remote Port—The IANA port number of any remote device communicating  
with this service.  
State—The state of the service. For UDP, only connections in the Active state  
display in the table. In the Active state, a connection is established between  
the switch and a client or server. The TCP states are:  
-
-
Listen—The service is listening for connection requests.  
Active—A connection session is established and packets are being  
transmitted and received.  
-
Established—A connection session is established between the switch  
and a server or client, depending on each device’s role with respect to  
this protocol.  
Configuring System Settings  
To configure the system settings:  
STEP 1 Click Status and Statistics > System Summary. The System Summary page  
opens.  
STEP 2 Click Edit to modify the following settings:  
System Location—Enter the location where the switch is physically located.  
System Contact—Enter the name of a contact person.  
Hostname—Enter the hostname. Use only letters, digits, and hyphens. Host  
names cannot begin or end with a hyphen. No other symbols, punctuation  
characters, or blank spaces are permitted (as specified in RFC1033,  
RFC1034, and RFC1035). The default hostname is the word switch  
followed by the last three octets of the base MAC address. For example, a  
switch with a MAC address of 010203040506 has the default hostname  
switch040506.  
STEP 3 Click Apply. Your changes are saved to the Running Configuration.  
Cisco Small Business SG200 Series 8-port Smart Switch  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Viewing Statistics  
Interface Statistics  
2
Interface Statistics  
Use the Interface page to display statistics for received and transmitted packets.  
To display this page, click Status and Statistics > Interface in the navigation  
window, or click Port Statistics under Device Status on the Getting Started  
page.  
Select the interface (Port or LAG) for which you want to display statistics, then  
select a refresh rate for the statistics. The following information displays for the  
selected interface:  
Total Bytes (Octets)—Total number of octets transmitted or received on the  
selected interface since the switch was last refreshed.  
Unicast Packets—Total number of unicast packets transmitted or received  
on the selected interface since the switch was last refreshed.  
Multicast Packets—Total number of multicast packets transmitted or  
received on the selected interface since the switch was last refreshed.  
Broadcast Packets—Total number of broadcast packets transmitted or  
received on the selected interface since the switch was last refreshed.  
Packets with Errors—Total number of packets with errors received on the  
selected interface since the switch was last refreshed.  
STP BPDUs—Total number of Spanning Tree Protocol (STP) Bridge Protocol  
Data Units (BPDUs) transmitted or received on the selected interface since  
the switch was last refreshed.  
RSTP BPDUs—Total number of Rapid Spanning Tree Protocol BPDUs  
transmitted or received on the selected interface since the switch was last  
refreshed.  
To clear statistics counters:  
Click Clear Interface Counters to reset all counters to 0 for the selected  
interface.  
Click Clear All Interface Counters to reset all counters to 0 for all  
interfaces.  
Cisco Small Business SG200 Series 8-port Smart Switch  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Viewing Statistics  
Etherlike Statistics  
2
Etherlike Statistics  
The system collects and reports statistics on ports and LAGs in accordance with  
RFC2665.  
To display this page, click Status and Statistics > Etherlike in the navigation  
window.  
Select the interface (Port or LAG) for which you want to display statistics, then  
select a refresh rate for the statistics. These statistics are cumulative since the last  
time the page was refreshed. The following information displays for the selected  
interface:  
Frame Check Sequence (FCS) Errors—FCS errors received.  
Single Collision Frames—Signal collision frame errors received.  
Late Collisions—Late collision frames received.  
Excessive Collisions—Excessive collision frames received.  
Multiple Collisions—Multiple collision frames received.  
Oversize Packets—Packets received that were longer than 1518 octets  
(excluding framing bits and including FCS octets) and were otherwise well-  
formed.  
Internal MAC Receive Errors—Internal MAC errors received on the LAG or  
interface.  
Alignment Errors—Packets received with alignment errors  
Pause Frames Received—Pause frames received on the LAG or interface.  
Pause Frames Transmitted—Pause frames transmitted from the LAG or  
interface.  
To clear statistics counters:  
Click Clear Interface Counters to reset all counters to 0 for the selected  
interface.  
Click Clear All Interface Counters to reset all counters to 0 for all  
interfaces.  
Cisco Small Business SG200 Series 8-port Smart Switch  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Viewing Statistics  
802.1X EAP Statistics  
2
802.1X EAP Statistics  
The switch ports can be configured to use the IEEE 802.1X Extensible  
Authentication Protocol (EAP) to control network access (see 802.1X). You can use  
the 802.1X EAP page to display information about EAP packets received on a port.  
To display the 802.1X EAP page, click Status and Statistics > 802.1X EAP in the  
navigation window.  
STEP 1 Select the Port for which you want to display statistics.  
STEP 2 Select a Refresh Rate for the statistics. These statistics are cumulative since the  
last time the page was refreshed.  
The following information displays for the selected interface:  
EAPOL Frames Received—Valid Extensible Authentication Protocol over  
LAN (EAPOL) frames received on the port.  
EAPOL Frames Transmitted—EAPOL frames transmitted through the port.  
EAPOL Start Frames Received—EAPOL Start frames received on the port.  
EAPOL Logoff Frames Received—EAPOL Logoff frames received on the  
port.  
Invalid EAPOL Frames Received—Unrecognized EAPOL frames received  
on this port.  
EAP Length Error Frames Received—EAPOL frames with an invalid packet  
body length received on this port.  
To clear statistics counters:  
Click Clear Interface Counters to reset all counters to 0 for the selected  
interface.  
Click Clear All Interface Counters to reset all counters to 0 for all  
interfaces.  
Cisco Small Business SG200 Series 8-port Smart Switch  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Viewing Statistics  
IPv6 DHCP Statistics  
2
IPv6 DHCP Statistics  
The switch can be configured to allow management over an IPv6 interface, and to  
receive its management IPv6 address through the Dynamic Host Configuration  
Protocol (DHCPv6). See Management Interface for information on configuring  
IPv6 and DHCP on the management interface. You can use the IPv6 DHCP  
Statistics page to display information on transmitted and received DHCPv6  
packets.  
To display this page, click Status and Statistics > IPv6 DHCP Statistics in the  
navigation window.  
Select a refresh rate for the page. The page displays the following statistics, which  
are cumulative since the last time the page refreshed.  
DHCPv6 Advertisement Packets Received  
DHCPv6 Reply Packets Received  
Received DHCPv6 Advertisement Packets Discarded  
Received DHCPv6 Reply Packets Discarded  
DHCPv6 Malformed Packets Received  
Total DHCPv6 Packets Received  
DHCPv6 Solicit Packets Transmitted  
DHCPv6 Request Packets Transmitted  
DHCPv6 Renew Packets Transmitted  
DHCPv6 Rebind Packets Transmitted  
DHCPv6 Release Packets Transmitted  
Total DHCPv6 Packets Transmitted  
Click Clear Counters to reset all counters to 0.  
Cisco Small Business SG200 Series 8-port Smart Switch  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Viewing Statistics  
RADIUS Statistics  
2
RADIUS Statistics  
The switch can be configured to communicate with a RADIUS server for user  
authentication. To display the RADIUS Statistics page, click  
Status and Statistics > RADIUS Statistics in the navigation window.  
Select a RADIUS server from the list and select a refresh rate for the page. The  
page displays the following statistics, which are cumulative since the last time the  
page refreshed.  
Access Requests—The number of Authentication-Request packets  
transmitted to the RADIUS server.  
Access Retransmissions—Number of Authentication-Request packets  
retransmitted to the RADIUS server.  
Access Accepts—Number of Authentication-Request packets accepted  
by the RADIUS server.  
Access Rejects—Number of Authentication-Request packets rejected by  
the RADIUS server.  
Access Challenges—Number of Access-Challenge packets sent by the  
RADIUS server to the switch.  
Malformed Access Responses—Number of reply packets from the  
RADIUS server that were malformed.  
Bad Authenticators—Number of Authentication-Request packets that  
contained invalid Message Authenticator attributes.  
Pending Requests—Number of Authentication-Request packets that were  
sent to the server and have not been replied to.  
Timeouts—Number of Authentication-Request packets that were timed out  
due to no response from the server.  
Unknown Types—Number of RADIUS packets of unknown type that were  
received by the switch.  
Packets Dropped—Number of RADIUS packets dropped by the switch.  
Click Clear All Statistics to reset all counters to 0.  
Cisco Small Business SG200 Series 8-port Smart Switch  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Viewing Statistics  
RMON  
2
RMON  
RMON (Remote Networking Monitoring) is an SNMP specification that enables an  
SNMP agent in the switch to monitor traffic statistics over a given period and send  
traps to an SNMP manager. The local SNMP agent compares actual, real-time  
counters against predefined thresholds and generates alarms, without the need  
for polling by a central SNMP management platform. This is an effective  
mechanism for proactive management, provided that you have right thresholds set  
relative to your network base line.  
RMON decreases the traffic between the manager and the switch because the  
SNMP manager does not have to frequently poll the switch for information, and  
enables the manager to get timely status reports because the switch reports  
events as they occur. Use the RMON Statistics page to display details about  
switch use, such as packet processing statistics and errors that have occurred on  
the switch.  
The RMON Statistics page displays detailed information regarding packet sizes  
and information regarding physical layer errors. The information shown is  
according to the RMON standard.  
To view statistics:  
STEP 1 Click Status and Statistics > RMON > Statistics in the navigation window.  
STEP 2 Select the port or LAG for which you want to display statistics.  
STEP 3 Select a refresh rate for the page.  
The following information displays for the selected interface:  
Bytes Received—Octets received on the interface since the switch was last  
refreshed. This number includes bad packets and FCS octets, but excludes  
framing bits.  
Drop Events—Number of times that packets have been dropped on the  
interface since the switch was last refreshed.  
Packets Received—Packets received on the interface, including bad  
packets, multicast and broadcast packets, since the switch was last  
refreshed.  
Broadcast Packets Received—Good broadcast packets received on the  
interface since the switch was last refreshed. This number does not include  
multicast packets.  
Cisco Small Business SG200 Series 8-port Smart Switch  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Viewing Statistics  
RMON  
2
Multicast Packets Received—Good multicast packets received on the  
interface since the switch was last refreshed.  
CRC & Align Errors—CRC and Align errors that have occurred on the  
interface since the switch was last refreshed.  
Undersize Packets—Undersized packets (less than 64 octets) received on  
the interface since the switch was last refreshed.  
Oversize Packets—Oversized packets (over 1518 octets) received on the  
interface since the switch was last refreshed.  
Fragments—Fragments (packets with less than 64 octets, excluding  
framing bits, but including frame check sequence octets) received on the  
interface since the switch was last refreshed.  
Jabbers—Packets received that were more than 1518 octets long and had  
an FCS error during the sampling session.  
Collisions—Collisions received on the interface since the switch was last  
refreshed.  
Frames of 64 Bytes—64-byte frames received on the interface since the  
switch was last refreshed.  
Frames of 65 to 127 Bytes—65-byte to 127-byte frames received on the  
interface since the switch was last refreshed.  
Frames of 128 to 255 Bytes128-byte to 255-byte frames received on the  
interface since the switch was last refreshed.  
Frames of 256 to 511 Bytes—256-byte to 511-byte frames received on  
the interface since the switch was last refreshed.  
Frames of 512 to 1023 Bytes—512-byte to 1023-byte frames received on  
the interface since the switch was last refreshed.  
Frames of 1024 to 1518 Bytes1024-byte to 1518-byte frames received  
on the interface since the switch was last refreshed.  
Cisco Small Business SG200 Series 8-port Smart Switch  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Viewing Statistics  
Logs  
2
Logs  
The switch generates messages to identify the state of the system and to assist in  
diagnosing issues that arise during switch operation. Messages might be  
generated in response to events, faults, or errors occurring on the platform and to  
changes in configuration.  
Logs of these messages are stored in RAM and flash memory. Entries in the flash  
log—unlike those in RAM—are stored across reboots.  
To access the log menu items, click Status and Statistics > View Log in the  
navigation window. The log menu includes the following pages:  
RAM Memory Log  
Use the RAM Memory page to view information about specific RAM (cache) log  
entries, including the time the log was entered, the log severity, and a description  
of the log.  
To display this page, click Status and Statistics > View Log > RAM Memory in  
the navigation window.  
NOTE This page might take up to 45 seconds to display when the table contains the  
maximum number of entries.  
The RAM Memory Log Table contains the following fields:  
Log Index—Numeric ID for the log entry.  
Log Time—Time at which the log was entered in the Log RAM Table.  
Severity—The log severity can be one of the following:  
-
-
-
-
-
-
Emergency (0)—System is unusable.  
Alert (1)—Action must be taken immediately.  
Critical (2)—Critical conditions.  
Error (3)—Error conditions.  
Warning (4)—Warning conditions.  
Notice (5)—Normal but significant conditions.  
Cisco Small Business SG200 Series 8-port Smart Switch  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Viewing Statistics  
Logs  
2
-
-
Informational (6)—Informational messages.  
Debug (7)—Provides detailed information about an event.  
You can use the Log Settings page to select the severity levels that are  
recorded in the log.  
Component - The software component or service that produced the log  
entry.  
Description—The log description.  
You can click Clear Logs to remove all log entries from RAM.  
Flash Memory Log  
The Flash Memory Log Files are persistent across reboots and contain information  
that includes the time the log was entered, the log severity, and a description of  
the event. Several log types are supported, and the system stores up to three  
versions of each type.  
The first few log entries that might be generated during the initial powering on of  
the switch and booting from the factory default configuration might be important  
to a troubleshooter. Therefore when the switch is first booted from the factory  
default configuration, it places the first 32 messages into the Start-up log and the  
balance of the messages are logged into the Operational log.  
If the logs are cleared, the Start-up log is retained unless the switch is booted from  
the factory default configuration. Only when the switch is booted from the factory  
default configuration is the Start-up log cleared and repopulated.  
To v i e w a F l a s h l o g :  
STEP 1 Click Status and Statistics > View Log > Flash Memory in the navigation window.  
STEP 2 Select a log type from the list:  
Default—Entries from the startup and operational logs.  
Startup—The first 32 log entries created during system restarts.  
Operational—Log entries created during system operation.  
STEP 3 Select a log version to display.  
Cisco Small Business SG200 Series 8-port Smart Switch  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Viewing Statistics  
Logs  
2
The Version 1 log is the current or most recently created log file, the Version 2 log  
is the next most recent, and the Version 3 log is the oldest file. When a new log file  
of the specified type is created, the Version 3 log is deleted and the Version 1 and  
Version 2 logs are renamed to Version 2 and Version 3, respectively.  
When a different version and log is selected, the new log automatically displays in  
the Flash Memory Log Table. (When the table contains the maximum number of  
entries, this page might take up to 45 seconds to display.)  
The Flash Memory Log Table contains the following fields:  
Log Index—Numeric ID for the log entry.  
Log Time—Time that the log was created in the Flash Memory Table.  
Severity—The log severity can be one of the following:  
-
-
-
-
-
-
-
Alert (1)—Action must be taken immediately.  
Critical (2)—Critical conditions.  
Error (3)—Error conditions.  
Warning (4)—Warning conditions.  
Notice (5)—Normal but significant conditions.  
Informational (6)—Informational messages.  
Debug (7)—Provides detailed information about an event.  
You can use the Log Settings page to select the severity levels that are  
recorded in the log.  
Component—Software component that produced the log entry.  
Description—The log description.  
Click Clear Logs to remove all log entries from flash memory.  
Click Backup Logs to open the Download/Backup Configuration/Log page,  
where you can use TFTP or HTTP to back up the log files to a TFTP server or  
network location. For more information, see Backing Up the Configuration File  
Cisco Small Business SG200 Series 8-port Smart Switch  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
Administration  
This chapter describes how to configure global system settings and perform  
diagnostics.  
It contains the following topics.  
Cisco Small Business SG200 Series 8-port Smart Switch  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Administration  
Configuring System Settings  
3
Configuring System Settings  
The System Settings page enables you to configure information that identifies the  
switch within the network.  
To configure system settings:  
STEP 1 Click Administration > System Settings in the navigation window.  
The System Description is hard-coded in the firmware.  
STEP 2 Enter the parameters:  
System Location—Description of the physical location of the switch.  
System Contact—Contact person for the switch.  
Hostname—Administratively-assigned name for this managed node. By  
convention, this is the fully-qualified domain name of the node. The default  
hostname is switch concatenated with the last 6 hex digits of the MAC  
address of the switch. Hostname labels contain only letters, digits and  
hyphens. Hostname labels cannot begin or end with a hyphen. No other  
symbols, punctuation characters, or blank spaces are permitted.  
NOTE: You can check the Set Default field to return the hostname to the  
default.  
STEP 3 Click Apply. The changes are saved to the Running Configuration.  
Cisco Small Business SG200 Series 8-port Smart Switch  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Administration  
Management Interface  
3
Management Interface  
Switch management interface enable access to the web-based switch  
configuration utility from a management station on the network. The switch  
supports configuration of a management VLAN that segregates the management  
traffic from other traffic on the switch.  
The management interface can be configured with an IPv4 address or with an IPv6  
address. The addresses can be configured statically or they can be obtained  
through DHCP/BOOTP servers.  
See the following topics for more information on the configuration pages available  
in the Administration > Management Interface menu:  
Configuring an IPv4 Management Interface  
You can use the IPv4 Interface page to configure the management VLAN and IPv4  
address.  
To configure the IPv4 management interface:  
STEP 1 Click Administration > Management Interface > IPv4 Interface in the navigation  
window.  
STEP 2 Select a management VLAN from the list.  
A port must be a member of the management VLAN to gain access to the web-  
based switch configuration utility. By default, VLAN 1 is configured as the  
management VLAN and all switch ports are configured as members of VLAN 1.  
At least one port must be a member of the management VLAN. The Member Ports  
list displays all current members of the selected management VLAN.  
Note that when you change the management VLAN, you must reassign any  
members of the previous management VLAN to the new VLAN to continue their  
management access.  
Cisco Small Business SG200 Series 8-port Smart Switch  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Administration  
Management Interface  
3
STEP 3 Select one of the following options for the IP Address Type:  
DHCP—The management interface obtains its IPv4 address from a DHCP  
server. DHCP is enabled by default and the switch requests an IP address  
from a DHCP server. If it is unable to get the IP address from a server, the  
switch falls back to the factory default static IP address. The System LED  
flashes continuously and the switch keeps trying to get its IP address from a  
DHCP server. If you set a static IP address, the LED stops flashing. The  
factory default static IP address is 192.168.1.254/24, with a default gateway  
IP address of 192.168.1.1.  
BOOTP—The management interface obtains its IPv4 address from a BOOTP  
server.  
Static—The management interface IPv4 address assigned in the IP  
Address field.  
If the IP Address Type is set to Static, specify the following:  
-
-
IP Address—Enter an IPv4 address.  
Mask—Enter a 32-bit network mask (for example, 255.255.255.0).  
Or select Prefix Length and specify the number of bits (0–32) that make  
up the network prefix (for example, 24).  
-
Default Gateway—Select User Defined and specify the default  
gateway IP address for management packets.  
Or select None to prevent management packets from being transmitted  
outside the subnet.  
Operational Default Gateway—The current default gateway in use.  
Renew DHCP—Select Renew DHCP and click Apply to send a request to  
the DHCP server for a new IP address and related parameters.  
STEP 4 Click Apply. Your changes are saved to the Running Configuration.  
!
CAUTION Changing the management IP address and IP Address Type terminates the current  
management session. Changing the Management VLAN and its port memberships  
might disrupt your communication with the switch and thus might terminate the  
current management session.  
Cisco Small Business SG200 Series 8-port Smart Switch  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Administration  
Management Interface  
3
Configuring an IPv6 Management Interface  
Use the IPv6 Interface page to enable access to the web-based switch  
configuration utility over IPv6. You can configure the switch to dynamically learn its  
IPv6 addresses and you can configure IPv6 addresses statically.  
To enable IPv6 management access:  
STEP 1 Click Administration > Management Interface > IPv6 Interface in the navigation  
window.  
The Interface field shows the VLAN ID of the management VLAN.  
STEP 2 Configure the following settings:  
IPv6 Mode—Select to enable IPv6 management access.  
IPv6 Address Auto Configuration—Select to enable the switch to auto-  
configure its link-local address(es) in EUI-64 format, using the MAC address  
of the port(s) for the link-local part of the address. The switch listens to router  
advertisements to detect and autoconfigure the global part of the address.  
DHCPv6—Select to enable the switch to obtain its IPv6 address(es) from a  
DHCPv6 server.  
IPv6 Gateway—Enter the link local address of the IPv6 router where the  
switch should send IPv6 packets destined for a device outside the subnet.  
STEP 3 Click Apply. Your changes are saved to the Running Configuration. You can click  
Cancel to clear the changes.  
Adding IPv6 Addresses  
The IPv6 Address table lists static addresses currently configured on the switch. It  
contains the following fields:  
IPv6 Address—IPv6 address in IPv6 global address format.  
The table includes the default IPv6 address. The switch creates this  
address automatically by inserting standard byte values into its 48-bit MAC  
address to create a 64-bit IPv6 address in EUI-64 format, as described in  
RFC 3513.  
Cisco Small Business SG200 Series 8-port Smart Switch  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Administration  
Management Interface  
3
DAD Status—The Duplicate Address Detection status. When you configure  
an IPv6 address on the switch, before the switch actually assigns the  
address, it performs neighbor discovery to detect if that address is already  
in use on the network.  
-
If the address is already in use, its DAD status is True, and the address is  
not usable for management access.  
-
If the address is found to be unique, its DAD status is False, and the  
address can be used for management access.  
You can configure multiple IPv6 addresses. Each address should have a different  
prefix so that the switch can be managed from stations on different subnets. When  
a route to one subnet fails, the switch can be managed from another subnet.  
To add a static IPv6 address:  
STEP 1 Click Add.  
STEP 2 Enter an IPv6 address followed by a slash (/) and the prefix length.  
STEP 3 Select EUI-64 if the address conforms to the EUI-64 format, whereby the first  
three to five octets are the Organizationally Unique Identifier (OUI) and the  
remaining octets are a unique assigned address.  
STEP 4 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
IPv6 Default Router Table  
When IPv6 management is enabled, the switch uses the IPv6 neighbor discovery  
process to identify the default router for communicating with devices outside the  
local IPv6 subnet. The default router in IPv6 networks is similar in function to the  
default router in IPv4 networks.  
The IPv6 Default Router table lists the default router IP address for each IPv6  
management address. A default router address consists of the link-local address  
of the IPv6 interface on the subnet.  
Cisco Small Business SG200 Series 8-port Smart Switch  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Administration  
Management Interface  
3
Viewing and Adding IPv6 Neighbors  
When IPv6 management is enabled, the switch identifies IPv6-enabled devices on  
attached links. The switch supports the discovery of up to 1,000 dynamic IPv6  
neighbors and supports the static configuration of IPv6 neighbors.  
The IPv6 Neighbors page lists dynamically discovered and statically configured  
neighbors, and enables adding static hosts.  
To view the IPv6 neighbor Table, click Administration > Management Interface >  
IPv6 Neighbors in the navigation window.  
The IPv6 Neighbor Table displays the following fields for each dynamic entry:  
IPv6 Address—IPv6 address of neighbor.  
MAC Address—MAC address of the neighbor.  
State—State of the neighbor. The following are the states for dynamic  
entries:  
-
Reachable—Confirmation was received within a preconfigured interval  
that the forward path to the neighbor is functioning properly. While in the  
Reachable state, the device takes no special action as packets are sent.  
-
Delay—More time has elapsed than a preconfigured interval since the  
last confirmation was received that the forward path was functioning  
properly.  
Age Updated—The time in seconds that has elapsed since an entry was  
added to the cache.  
Type—Neighbor discovery cache information entry type (static or  
dynamic).  
You can click Clear Dynamic Neighbors to clear the table.  
Adding Static IPv6 Neighbors  
The switch supports up to 16 static IPv6 neighbor entries. To add a static  
neighbor:  
STEP 1 Click Add.  
STEP 2 Enter an IPv6 global address (not including a prefix length).  
STEP 3 Enter the MAC address of the neighbor.  
Cisco Small Business SG200 Series 8-port Smart Switch  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Administration  
Managing User Accounts  
3
STEP 4 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
Managing User Accounts  
One management user is configured on the switch by default:  
User Name: cisco  
Password: cisco  
You can use the User Accounts page configure up to five additional users and to  
change a user password.  
Adding a User  
To add a new user:  
STEP 1 Click Administration > User Accounts in the navigation window.  
The User Account Table displays the currently configured users.  
STEP 2 Click Add.  
STEP 3 Enter a user name between 1 to 32 alphanumeric characters. Only numbers 0-9  
and letters a-z (upper or lower) are allowed for user names.  
STEP 4 Enter a password between 0 and 64 characters (depending upon the Password  
Strength setting) and confirm the password.  
Cisco Small Business SG200 Series 8-port Smart Switch  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Administration  
Managing User Accounts  
3
As you enter a password, the number and color of vertical bars changes to  
indicate the password strength, as follows:  
Red—The password fails to meet the minimum complexity requirements.  
The text “Below Minimum” displays to the right of the meter.  
Orange—The password meets the minimum complexity requirements but  
the password strength is weak. The text “Weak” displays to the right of the  
meter.  
Green—The password is strong. The text “Strong” displays to the right of the  
meter.  
If Password Strength Enforcement is enabled, Apply is not available until the  
strength meter is orange and the password is confirmed.  
When adding a user, you can temporarily disable the password strength check to  
allow configuring a password that does not meet the strength check criteria. Click  
Disable Password Strength Enforcement and then click OK when the warning  
displays.  
To disable the Password Strength Enforcement for all users, or to configure its  
characteristics, use the Password Strength page.  
STEP 5 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
Changing a User Password  
To change a user password:  
STEP 1 Click Administration > User Accounts in the navigation window.  
STEP 2 Select the user to configure and click Edit.  
STEP 3 Enter a password between 0 and 64 characters (depending upon the Password  
Strength setting) and confirm the password.  
Cisco Small Business SG200 Series 8-port Smart Switch  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Administration  
Managing User Accounts  
3
As you enter a password, the number and color of vertical bars changes to  
indicate the password strength, as follows:  
Red—The password fails to meet the minimum complexity requirements.  
The text “Below Minimum” displays to the right of the meter.  
Orange—The password meets the minimum complexity requirements but  
the password strength is weak. The text “Weak” displays to the right of the  
meter.  
Green—The password is strong. The text “Strong” displays to the right of the  
meter.  
If Password Strength Enforcement is enabled, Apply is not available until the  
strength meter is orange and the password is confirmed.  
When adding a user, you can temporarily disable the password strength check to  
allow configuring a password that does not meet the strength check criteria. Click  
Disable Password Strength Enforcement and then click OK when the warning  
displays.  
To disable the Password Strength Enforcement for all users, or to configure its  
characteristics, use the Password Strength page.  
STEP 4 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
Deleting a User  
You can delete all users except the default user, typically the cisco user ID.  
To delete a user, select the user name in the User Accounts Table and click Delete.  
Cisco Small Business SG200 Series 8-port Smart Switch  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Administration  
Enabling Management Services  
3
Enabling Management Services  
Use the Management Services page to enable and disable the available types of  
management connections. By default, HTTP access is enabled.  
Configuring the Idle Session Timeout  
The software automatically logs users off the management interface when there is  
no activity for a specified period of time. The user must reauthenticate after a  
timeout. You can use the Idle Session Timeout page to configure the timeout  
period.  
To configure the timeout period:  
STEP 1 Click Administration > Idle Session Timeout in the navigation window.  
STEP 2 Specify the parameter:  
HTTP Session Timeout—The inactivity timeout for HTTP sessions. The  
value must be in the range of 1 to 60 minutes. The default value is 10  
minutes.  
STEP 3 Click Apply. Your changes are saved to the Running Configuration.  
Login Sessions  
The Login Sessions page displays active management login sessions. To display  
this page, click Administration > Login Sessions in the navigation window.  
The page lists the following information for each user currently logged in:  
ID—A system-generated ID for the login session.  
User Name—Name that the user used to log in.  
Connection From—IP address of the host.  
Idle Time—Time that has elapsed since the last activity from this user.  
Session Time—Amount of time that has elapsed since this user logged in.  
Session Type—Protocol in use for the management session (HTTP).  
Cisco Small Business SG200 Series 8-port Smart Switch  
42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Administration  
Login History  
3
Authentication Method—Lists the protocol used to authenticate the  
session login. It can be Radius, Local, or None.  
Login History  
You can use the Login History page to display data on previous logins to the  
management software. To display this page, click Administration > Login History  
in the navigation window.  
This page displays the following fields:  
Login Time—Date and time the user logged in.  
User Name—Name that the user used to log in.  
Protocol—Protocol the user is using to the configuration software, which  
can be HTTP, Telnet, Serial, SSH, or SNMP.  
Location—IP address of the host.  
Time Settings  
A system clock is used to provide a network-synchronized time-stamping service  
for switch software events such as message logs. You can configure the system  
clock manually or configure the switch as a Simple Network Time Protocol (SNTP)  
client that obtains the clock data from a server.  
See the following topics for information on the configuration pages available in the  
Administration > Time Settings menu:  
Setting System Time  
Use the System Time page to set the system time manually or to configure the  
system to acquire its time settings from an SNTP server. To display this page, click  
Administration > Time Settings > System Time in the navigation window.  
Cisco Small Business SG200 Series 8-port Smart Switch  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Administration  
Time Settings  
3
By default, the time is configured locally on the switch.  
NOTE The actual system time, date, time zone information, and daylight savings time  
status appears at the bottom of the page.  
Specifying Clock Settings Locally  
To configure the time settings locally:  
STEP 1 On the System Time page, select Use Local Settings.  
STEP 2 Select Timezone Source - DHCP if you want to have the switch to acquire its  
timezone from a DHCP server.  
STEP 3 Select Set Date/Time from Computer to have the switch retrieve the time  
settings from the computer you are using to access the switch.  
Or clear this field and configure the following time settings:  
Date—Enter the date in mm/dd/yyyy format, such as 01/01/2010 for  
January 1, 2010.  
Local Time—Enter the current time in HH:mm:ss format, such as 22:00:00 for  
10 p.m. (The hint text displays HH if the time is based on a 24-hour clock or  
hh if the time is in 12-hour clock format.)  
GMT Time Zone Offset—Select the number of hours and minutes  
difference between the local time zone and Greenwich Mean Time (GMT).  
STEP 4 In the Time Zone Acronym field, specify an optional acronym up to four characters  
to identify the configured settings. This field is for reference only.  
STEP 5 Select Daylight Saving to configure Daylight Savings Time (DST) settings, if  
applicable to your time zone. When selected, configure the following fields:  
Cisco Small Business SG200 Series 8-port Smart Switch  
44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Administration  
Time Settings  
3
USA/European/Other—Select USA or European to have the DST offset  
configured to the values used in those locations. Or select Other to configure  
the settings manually. When configuring manually, you can configure the  
settings for the upcoming DST period only, or you can configure recurring  
settings.  
DST Time Zone Acronym—Specify an optional acronym up to four  
characters to identify the configured settings. This field is for reference only.  
(The characters ', ", %, and ? are not supported.)  
Daylight Savings Offset—Specify the number of minutes to move the clock  
forward when DST begins.  
From/To—Specify the date and time when DST starts and ends.  
Recurring—Select to specify recurring DST periods by selecting the day of  
the week and number of weeks into the year when DST begins and ends  
each year.  
STEP 6 Click Apply. Your changes are saved to the Running Configuration.  
Configuring the Switch as an SNTP Client  
You can also configure the switch to acquire time from an SNTP server by  
configuring the switch SNTP Settings.  
To configure the switch to acquire time settings from an SNTP server:  
STEP 1 On the System Time page, select Use SNTP Server.  
STEP 2 Configure the SNTP client operation mode of the switch:  
Unicast—Configures the switch to send unicast SNTP requests to  
configured unicast SNTP servers only. You must add at least one unicast  
SNTP server to enable this feature. (Default SNTP servers require that  
Unicast is selected.)  
Broadcast—Configures the switch to get its time settings from SNTP  
messages broadcast from SNTP servers.  
STEP 3 Select Timezone Source - DHCP if you want to have the switch to acquire its  
timezone from a DHCP server.  
STEP 4 Configure the GMT Time Zone Offset by selecting the number of hours and  
minutes difference between the local time zone and Greenwich Mean Time (GMT),  
and specify a Time Zone Acronym.  
Cisco Small Business SG200 Series 8-port Smart Switch  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Administration  
Time Settings  
3
NOTE: If the Timezone Source - DHCP setting is enabled and time zone  
information is received from the DHCP server, then that information will be used to  
adjust instead of the manually configured GMT Time Zone Offset and Acronym.  
STEP 5 Configure the Daylight Savings Time settings, as described in step 5 in Specifying  
STEP 6 Click Apply. Your changes are saved to the Running Configuration.  
configure additional SNTP settings, such as polling intervals, unicast server  
addresses, and authentication information the switch needs to access SNTP  
servers.  
Configuring the SNTP Setting  
The switch supports the Simple Network Time Protocol (SNTP). SNTP ensures  
accurate network device time synchronization up to the millisecond. Time  
synchronization is performed by a network SNTP server. The switch operates as  
an SNTP client only and cannot provide time services to other systems.  
To display the SNTP Setting page, click Administration > Time Settings >  
SNTP Setting in the navigation window.  
Configuring the SNTP Setting  
STEP 1 Ensure that the Use SNTP Server option is selected on the System Time page and  
that the Unicast or Broadcast mode is selected as required.  
STEP 2 On the SNTP Setting page, configure the following:  
Cisco Small Business SG200 Series 8-port Smart Switch  
46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Administration  
Time Settings  
3
Client Port—The logical port number to use for the SNTP client on the  
switch. The default is the well-known IANA port number for this service, 123.  
Unicast Poll Interval—The relative rate at which the switch sends  
synchronization messages to the SNTP server. This field is editable only  
when SNTP Unicast reception is selected. Enter a value from 3 to 16. The  
default value is 3. The actual interval, in seconds, is the specified value to the  
power of 2; for example, if you enter 4, the poll interval is 16 seconds.  
Broadcast Poll Interval—The relative rate that the switch broadcasts  
synchronization messages. This field is editable only when SNTP Broadcast  
reception is selected. Enter a value from 3 to16. The default value is 3. The  
actual interval, in seconds, is the specified value to the power of 2; for  
example, if you enter 4, the poll interval is 16 seconds."  
If the switch detects a server, it ignores time broadcasts from other SNTP  
servers unless the Broadcast Poll Interval expires three consecutive times  
without an update received from the server.  
STEP 3 Click Apply. Your changes are saved to the Running Configuration.  
Adding and Modifying SNTP Servers  
The Unicast SNTP Servers Table displays the following information for each SNTP  
server that you configure:  
SNTP Server—IP address or hostname of the SNTP server.  
Authentication Key ID—Encryption key required to communicate with the  
SNTP server.  
Last Attempt Time—The time of the most recent attempt by the switch to  
synchronize with an SNTP unicast server.  
Status—Operating status of the SNTP server. Possible values are:  
-
-
-
-
Success—Client could get the time from this server.  
Request timed-out—Client request timed out.  
Bad Date Encoded—A bad date format was received from server.  
Version Not Supported—Server does not support the SNTP version  
configured on the switch.  
-
Server Unsynchronized—Switch time is not synchronized with the  
server.  
Cisco Small Business SG200 Series 8-port Smart Switch  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Administration  
Time Settings  
3
-
-
Server Kiss of Death—SNTP server has replied with a kiss of death  
packet, instructing the switch to stop sending requests to the server, due  
to traffic spikes or other error conditions.  
Other—The status could not be determined.  
Last Response—Time of the last response from the SNTP server.  
Version—SNTP protocol version the server uses.  
Port—Protocol port number (123 is a well-known port number for SNTP).  
Polling Mode—Whether the switch is configured to send SNTP requests to  
this server (Enabled or Disabled).  
Total Unicast Requests—The total number of synchronization requests the  
switch has made to the unicast server.  
To edit the settings for a server, check the box to select it, and then click Edit. To  
remove a server, check the box to select it, and then click Delete. To add a new  
server, click Add, and then enter the settings, as described below.  
To add an SNTP server:  
STEP 1 Click Add.  
STEP 2 Enter the parameters:  
SNTP Server—Enter an IPv4 address or a domain name. To use a domain  
name, ensure that the DNS service is enabled on the switch (see Domain  
Authentication Key—Select Enable if authentication is needed when  
communicating with the SNTP server.  
Authentication Key ID—If authentication is used, select the Authentication  
Key ID from the list. See Configuring SNTP Authentication for information  
on configuring authentication keys.  
Polling Mode—Select Enable to allow the switch to send requests to this  
server.  
Cisco Small Business SG200 Series 8-port Smart Switch  
48  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Administration  
Time Settings  
3
Port—Specify the UDP port number to be specified in the SNTP message  
headers. By default, the port number is the well-known IANA value of 123.  
Version—Specify the highest SNTP version (1–4) that the server supports.  
STEP 3 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
Viewing Active Server Properties and Global Parameters  
The SNTP Setting page displays the following properties for the SNTP server, if  
any, from which the switch most recently acquired its time settings. This page also  
displays global (nonconfigurable) parameters.  
Active Server:  
Server Host Address—IP address of the SNTP server.  
Server Type—IP protocol version the server uses (IPv4 or IPv6).  
Server Stratum—Hierarchical level of the SNTP server that identifies its  
distance from a reference clock.  
Server Reference Id—32-bit code that identifies the reference clock that  
this server uses.  
Server Mode—Mode in which the server is operating:  
-
-
-
Unicast—The SNTP server listens to unicast requests from SNTP  
clients.  
Broadcast—The SNTP server sends broadcast messages periodically  
to SNTP clients.  
Reserved—No reply has been received from an SNTP Server. When a  
response is received from a server, it is overwritten with one of the valid  
states (Broadcast or Unicast).  
Global Parameters:  
SNTP Client Version—The highest SNTP protocol version supported by the  
switch.  
Last Update Time—The time of receipt of the most recent SNTP update.  
Cisco Small Business SG200 Series 8-port Smart Switch  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Administration  
Time Settings  
3
Last Unicast Attempt Time—The time of the most recent attempt by the  
switch to synchronize with an SNTP unicast server.  
Client Mode—The configured SNTP client mode (Unicast or Broadcast).  
See the System Time to configure this mode.  
Server Maximum Entries—Maximum number of servers that you can  
configure on the switch.  
Server Current Entries—Number of SNTP servers currently configured on  
the system, as listed in the Unicast SNTP Servers Table.  
Broadcast Count—Number of SNTP broadcast packets that the switch has  
received from SNTP servers.  
Configuring SNTP Authentication  
Use the SNTP Authentication page to configure encryption keys, which contain  
the identifying information that the switch uses to authenticate to STNP servers.  
You also use this page to enable the SNTP authentication service.  
When you define SNTP servers that the switch can use, you specify whether a  
server uses authentication and which authentication key it uses.  
NOTE You must configure at least one trusted authentication key before you enable SNTP  
authentication. Otherwise, the Failed to enable SNTP Authentication  
message displays.  
To configure an authentication key and enable this service:  
STEP 1 Click Administration > Time Settings > SNTP Authentication in the navigation  
window.  
The SNTP Authentication Table displays each currently configured authentication  
key and whether the key is currently enabled for use as a trusted key.  
STEP 2 Select Enable to require the switch to authenticate to an SNTP server before  
synchronizing its time.  
STEP 3 Click Apply. Your changes are saved to the Running Configuration.  
Cisco Small Business SG200 Series 8-port Smart Switch  
50  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Administration  
System Logs  
3
STEP 4 In the SNTP Authentication Table, click Add to add a key to the list.  
STEP 5 Enter the parameters:  
Authentication Key ID—The key number. When you define an SNTP server  
on the system, you specify which key it uses for authentication.  
Authentication Key—The value of the key. The value is the cryptographic  
key that is used to encrypt and decrypt SNTP messages to and from the  
server.  
Trusted Key—Indicates whether this key is a trusted key. Only trusted keys  
are available for use. At least one trusted key must be configured to enable  
the SNTP authentication service.  
Keys are used with unicast SNTP servers only. A key is used to authenticate  
an SNTP server only when the key is enabled as trusted. A keys that is  
configured on the switch but specified as untrusted will not be used. An  
administrator can add an untrusted key to have it available for use at another  
time.  
STEP 6 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
System Logs  
The switch generates messages in response to events, faults, errors, changes in  
the configuration, and other occurrences. These messages are stored locally in  
the system memory and are forwarded to one or more centralized points of  
collection for monitoring or long-term archiving.  
See the following topics for more information on the configuration pages available  
in the Administration > System Log menu:  
Cisco Small Business SG200 Series 8-port Smart Switch  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Administration  
System Logs  
3
Configuring Log Settings  
Use the Log Settings page to enable logs globally, and to define which event  
types are logged into temporary memory (RAM) and persistent memory (flash).  
Log messages in flash memory are retained across a reboot. When the log is full,  
the oldest events are automatically deleted and replaced with the new entries.  
To configure log settings:  
STEP 1 Click Administration > System Log > Log Settings in the navigation window.  
STEP 2 Enable the types of logging to be performed on the system:  
Log Aggregation—When enabled, this feature combines multiple logs of the  
same type into a single log message. If two or more identical log messages  
are received consecutively within a configured time interval, then these  
messages are aggregated into a single log message.  
Log Aggregation Interval—If Log Aggregation is enabled, specify the  
interval in seconds. Consecutive messages that are received within this  
interval will be aggregated into a single log message. The range is 15  
seconds to 120 seconds.  
RAM Memory Logging—Select to enable logging in RAM.  
Flash Memory Logging—Select to enable logging in flash memory.  
Flash Log Size—Enter the maximum number of log messages to store in the  
flash memory log.  
STEP 3 Enable the event severity levels to be logged for each log type. The severity levels  
are listed from the highest to the lowest severity, as follows:  
Emergency—System is not usable.  
Alert—Action is needed.  
Critical—System is in a critical condition.  
Error—System is in error condition.  
Warning—System warning has occurred.  
Notice—System is functioning properly, but a system notice has occurred.  
Cisco Small Business SG200 Series 8-port Smart Switch  
52  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Administration  
System Logs  
3
Informational—Device information.  
Debug—Provides detailed information about an event.  
NOTE: When you select a severity level, any events of that level or higher are  
automatically selected for logging.  
STEP 4 Click Apply. Your changes are saved to the Running Configuration.  
Configuring Remote Log Servers  
You can define one or more remote log servers that the switch sends Syslog  
messages to. Use the Remote Log Servers page to define log servers and to set  
the severity level of the log events to be sent to the server.  
To enable Syslog operation and configure a remote log servers:  
STEP 1 Click Administration > Remote Log Servers in the navigation window.  
STEP 2 For the Syslog Logging mode, click Enable, and then configure the following  
settings:  
Facility—Select a value from the list that identifies the classification of  
syslog messages from this switch. The meaning of these values (Local 0  
through Local 7) is determined by the network administrator.  
Local Port—Specify the IANA port number for the switch. The default is the  
well-known port number for the Syslog protocol, 514.  
STEP 3 Click Apply.  
STEP 4 In the Remote Log Server Table, click Add.  
STEP 5 Enter the parameters:  
Log Server—IPv4 address or hostname of the server to send logs to.  
UDP Port—The logical UDP port number the remote server uses for the  
Syslog protocol. The default value is the well-known IANA Syslog port  
number, 514.  
Minimum Severity—Only items that meet or exceed this severity level are  
sent to the remote server. See Configuring Log Settings for a description of  
the severity levels.  
Cisco Small Business SG200 Series 8-port Smart Switch  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Administration  
File Management  
3
STEP 6 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
File Management  
You can use the file management features to upgrade or backup the firmware,  
update the language files, save configuration changes, copy configuration files  
within the switch, and set up autoconfiguration feature.  
NOTE When any download or upload to or from the switch is in progress, all management  
access to the switch is blocked until the transfer is complete to protect the switch  
from any unknown changes.  
NOTE When logging in by using HTTP/HTML, and you can choose from more than one  
network port, you should the lowest number port.  
See the following topics for more information on the configuration pages available  
in the File Management menu:  
Cisco Small Business SG200 Series 8-port Smart Switch  
54  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Administration  
File Management  
3
Files and File Types  
The following types of configuration and operational files are found on the switch:  
Running Configuration—Parameters that are currently used by the switch  
to operate. It is the only file type that is modified by you when the parameter  
values are changed by using one of the configuration interfaces, and must be  
manually saved to another file type, such as the Startup Configuration, to be  
preserved after a reboot.  
If the switch is rebooted, the Running Configuration is lost. When the switch  
is rebooted, the Startup Configuration stored in the Flash is copied to the  
Running Configuration stored in RAM.  
Startup Configuration—The parameter values that were saved by you by  
copying another configuration (usually the Running Configuration) to the  
Startup Configuration.  
The Startup Configuration is retained in Flash and is preserved any time the  
switch is rebooted. When it is rebooted, the Startup Configuration is copied  
to RAM and identified as the Running Configuration.  
Backup Configuration—A manual copy of the parameter definitions for  
protection against system shutdown or for the maintenance of a specific  
operating state. You can copy the Mirror Configuration, Startup  
Configuration, or Running Configuration to a Backup Configuration file. The  
Backup Configuration exists in Flash and is preserved if the device is  
rebooted.  
Mirror Configuration—A copy of the Running Configuration, created by the  
switch after:  
-
-
The switch has been operating continuously for 24 hours.  
Configuration changes have been made to the Running Configuration in  
the previous 24 hours, but have not been saved.  
Only the switch can copy the Running Configuration to the Mirror  
Configuration. However, you can copy from the Mirror Configuration to other  
file types or to another device.  
Firmware—The operating system. More commonly referred to as the  
image.  
Boot Code—Controls the basic system startup and launches the firmware  
image.  
Cisco Small Business SG200 Series 8-port Smart Switch  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Administration  
File Management  
3
Language File—The dictionary that allows the windows to be displayed in  
the selected language.  
Flash Log—SYSLOG messages stored in Flash memory.  
Operational Log—Events that are not saved to the Startup Log.  
Startup Log—The first 32 messages logged when the switch is booted.  
Subsequent messages are logged into the Operational Log. The Startup  
Log is not aged out; it retains the messages until the switch is rebooted.  
Trap Log—SNMP traps.  
SSH Files—Encryption keys used for secure shell communication.  
Upgrading and Backing Up Firmware and Language Files  
You can use the Upgrade/Backup Firmware/Language page to:  
Upgrade the firmware by downloading a new image from a server.  
Upgrade the boot code by downloading a new boot file from a server.  
Update the language files by downloading a new file from a server.  
Language files determine the language options for the web-based switch  
configuration utility. You can select the display language when you log in.  
Back up the firmware image to a server.  
English is always the default language.  
NOTE You can also back up or restore the configuration files. See Downloading and  
Cisco Small Business SG200 Series 8-port Smart Switch  
56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Administration  
File Management  
3
To upgrade or backup the firmware or to update the boot code or language file:  
STEP 1 Click Administration > File Management > Upgrade/Backup Firmware/  
Language in the navigation window.  
STEP 2 Enter the parameters:  
Transfer Method—Select the protocol to be used for the file transfer (TFTP  
or HTTP), which corresponds to the type of server you are downloading to  
or uploading from.  
Save Action—Select Upgrade to download a file to the switch, or select  
Backup to copy a file from the switch to the server.  
File Type—Select the type of file to upgrade or back up (you can back up  
only the firmware image):  
-
-
-
Firmware Image—Controls all switch features and interfaces.  
Boot Code—Controls the initial system bootup.  
Language File—Strings used by the system interface to display the  
selected language.  
TFTP Server (TFTP only)—Specify the IPv4 or IPv6 address of the TFTP  
server. Or specify the server name if DNS is enabled in the IP configuration  
(see Domain Name System).  
Source File Name—For upgrades via TFTP, enter the filename, including the  
path. For upgrades via HTTP, browse and select the file from your computer.  
Destination File Name—For backups via TFTP, enter the filename, including  
the path. This field does not appear for backups via HTTP.  
STEP 3 Click Apply to begin the upgrade or backup. A progress bar indicates the status of  
the file transfer. A typical image transfer might take 5-6 minutes to complete.  
STEP 4 Reboot the switch to use the new configuration or firmware.  
Cisco Small Business SG200 Series 8-port Smart Switch  
57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Administration  
File Management  
3
WARNING Ensure that power to the switch remains uninterrupted while downloading an image  
or a boot code file to the switch. If a power failure occurs while downloading a file,  
the file contents in persistent memory are lost.  
If a power outage occurs during boot code file download, the switch will not be  
able to boot. Contact the Cisco Small Business Support Center for assistance.  
If a power outage occurs during image download, the image will not load, but the  
boot loader will continue to be operational. See Firmware Recovery Over HTTP  
for instructions on downloading a working image.  
Downloading and Backing Up the Configuration and Log Files  
You can use the Download/Backup Configuration/Log page to download a saved  
configuration file to the switch to restore previously saved settings, or back up the  
current configuration file to a network location. You also can use this page to back  
up log files.  
Downloading a Configuration File to Restore Settings  
To download a configuration file to the switch to restore a previously backed-up  
file:  
STEP 1 Click Administration > File Management > Download/Backup Configuration/  
Log in the navigation window.  
STEP 2 Select the Transfer Method (HTTP or TFTP).  
STEP 3 For the Save Action, select Upgrade to download the file that will be specified  
below.  
Cisco Small Business SG200 Series 8-port Smart Switch  
58  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Administration  
File Management  
3
STEP 4 Enter the following parameters:  
TFTP Server (TFTP only)—Specify the IPv4 or IPv6 address of the TFTP  
server. Or specify the server name if DNS is enabled in the IP configuration  
(see Domain Name System).  
Source File Name—For TFTP, specify the filename, including the path. For  
HTTP, browse to select the file from your computer.  
Destination File Type—Select one of the following options:  
-
-
Startup Configuration—If the specified configuration file is valid, then it  
will replace the current Startup Configuration file. It will be the active  
configuration file when you reboot.  
Backup Configuration—The specified file will replace the current  
backup configuration file.  
STEP 5 Click Apply to begin the upgrade. A progress bar indicates the status of the  
upgrade.  
!
CAUTION Ensure that power to the switch remains uninterrupted while the configuration file  
is downloading to the switch. If a power failure occurs while downloading the  
configuration file, the file is lost and the process must be restarted.  
Backing Up the Configuration File and Logs  
To back up the configuration file or log:  
STEP 1 Click Administration > File Management > Download/Backup Configuration/  
Log in the navigation window.  
STEP 2 Select the Transfer Method (HTTP or TFTP).  
STEP 3 For the Save Action, select Backup.  
Cisco Small Business SG200 Series 8-port Smart Switch  
59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Administration  
File Management  
3
STEP 4 Enter the parameters:  
TFTP Server (TFTP only)—Specify the IP address of the TFTP server. Or  
specify the server’s domain name if DNS is enabled in the IP configuration  
(see Domain Name System).  
Destination File Name (TFTP only)—Specify a name for the saved file,  
including the path on the TFTP server.  
Source File Type—Select the configuration file type:  
-
Running Configuration—The current configuration, including any  
changes applied in the current management session.  
-
Startup Configuration—The configuration file saved to flash memory.  
This file does not include any configuration changes applied in RAM but  
not yet saved to the switch.  
-
-
Backup Configuration—An additional configuration file saved on the  
switch for use as a backup. The administrator can copy the Backup  
Configuration file to the Startup Configuration file type, then reboot the  
switch to use the Backup Configuration file.  
Mirror Configuration—If the Running Configuration is not modified for at  
least 24 hours, it is automatically saved to a Mirror Configuration file type,  
and a log message with severity alert is generated to indicate that a new  
mirror file is available. This feature allows the administrator to view the  
previous version of the configuration before it is saved to the Startup  
Configuration file type or to copy the Mirror Configuration file type to  
another configuration file type. If the switch is rebooted, the Mirror  
Configuration is reset to the factory default parameters.  
-
-
Flash Log—Log of events saved to flash memory.  
Operational Log—Log of events in switch RAM but not saved to flash  
memory.  
-
Startup Log—The first 32 messages logged when the switch is booted.  
Subsequent messages are logged into the Operational Log.  
STEP 5 If you are backing up the Operational Log or Startup Log, select the Log Version to  
back up.  
The switch maintains three versions of each log. The Version 1 log is the current or  
most recently created log file, the Version 2 log is the next most recent, and the  
Version 3 log is the oldest.  
STEP 6 Click Apply.  
Cisco Small Business SG200 Series 8-port Smart Switch  
60  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Administration  
File Management  
3
For HTTP backups, you are prompted to browse to a location to save the file. A  
progress bar indicates the status of the file transfer.  
Delete Configuration  
The Delete Configuration page enables you to delete the Startup configuration or  
the Backup configuration. If you delete both the startup and the backup  
configuration files, when the switch reboots it will use the default configuration file.  
To delete the Startup or Backup Configuration file:  
STEP 1 Click Administration > File Management > Delete Configuration in the navigation  
window.  
STEP 2 Select the Startup Configuration or Backup Configuration file type.  
STEP 3 Click Apply.  
Copying and Saving Configuration Files  
The Copy/Save Configuration page enables you to copy files within the file  
system. For example, you can copy the Backup Configuration file to the Startup  
Configuration file so that it will be used the next time you boot up the switch.  
To copy a file to the Startup or Backup Configuration file:  
STEP 1 Click Administration > File Management > Copy/Save Configuration in the  
navigation window.  
STEP 2 Select the Source File Name:  
Cisco Small Business SG200 Series 8-port Smart Switch  
61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Administration  
File Management  
3
Running Configuration—Current configuration, including any changes  
applied in the current management session.  
Startup Configuration—Configuration file type used when the switch last  
booted. This does not include any configuration changes applied but not yet  
saved to the switch.  
Backup Configuration—Backup configuration file type saved on the switch.  
Mirror Configuration—If the Running Configuration is not modified for at  
least 24 hours, it is automatically saved to the Mirror Configuration file type,  
and a log message with severity level Alert is generated to indicate that a  
new Mirror Configuration file is available. The Mirror Configuration file can be  
used when the switch has problems booting with the Startup or Backup  
Configuration file types. In such cases, the administrator can copy the Mirror  
Configuration to either the Startup or Backup Configuration file type and  
reboot.  
STEP 3 For the Destination File Name, select the file type to be overwritten with the file  
you are copying:  
Startup Configuration—Configuration file type used when the switch last  
booted. This does not include any configuration changes applied but not yet  
saved to the switch.  
Backup Configuration—Backup configuration file type saved on the switch.  
STEP 4 Click Apply to begin the copy process.  
When complete, a window displays the message, Copy Operation Successful.  
DHCP Auto Configuration  
The switch supports Auto Configuration through DHCP to facilitate configuration  
deployment and upgrades. This feature enables the configuration of a switch  
automatically when no configuration file is found in device storage during the boot  
process or when a newer configuration file is available for download.  
NOTE The Auto Configuration feature depends upon the proper configuration of other  
devices in the network, including a DHCP or BOOTP server, a TFTP server, and if  
necessary, a DNS server.  
Cisco Small Business SG200 Series 8-port Smart Switch  
62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Administration  
File Management  
3
Overview  
During startup, the switch attempts communication with a DCHP server to obtain  
its IP address and other information. If Auto Configuration is enabled, the switch  
may also download a startup configuration file, depending on the TFTP server and  
startup configuration file name it receives from the DHCP server. Auto  
Configuration is enabled by default.  
DHCP Auto Configuration initiates when the switch is rebooted with Auto  
Configuration enabled, and any of the following conditions occur:  
1. Information on the TFTP server and Startup Configuration is received from the  
DHCP server, and Auto Configuration has not previously downloaded the  
configuration file.  
2. Information on the TFTP server and Startup Configuration is received from the  
DHCP server, and the configuration file name differs from the file name  
advertised in a previous DHCP message.  
3. The Startup Configuration file is not present and no information on the TFTP  
server or Startup Configuration is received from the DHCP server.  
When conditions 1 and 2 occur, the switch saves the file to flash memory. Upon  
subsequent startups, it compares the stored file name to the name specified in  
option 66/67 in the current DHCP message. If they differ, the new file is  
downloaded and written to flash memory.  
NOTE When the system boots up for the first time, the switch does not have a specific  
name for the configuration file received from the DHCP server, as it has not  
downloaded a Startup Configuration file yet. If these options are received in the  
DHCP message, then that file name is saved and the download process begins.  
When option 3 occurs, the switch looks for the TFTP server and Startup  
Configuration file as described in Default Network Configuration File.  
DHCP Server Message Details  
Any of the following fields might be returned by a BOOTP or DHCP server and  
processed by the switch:  
The name of the configuration file (boot file or option 67) to be downloaded  
from the TFTP server.  
The identification of the TFTP server from which to obtain the boot file.  
The TFTP server IP address can be deduced from the multiple sources in a  
DHCP reply. The switch makes its selection based on the following criteria,  
from the highest priority to the lowest:  
Cisco Small Business SG200 Series 8-port Smart Switch  
63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Administration  
File Management  
3
1. The sname field in a DHCP or BOOTP reply.  
2. The TFTP server name (option 66) field in a DHCP reply.  
3. The TFTP server address (option 150) field in a DHCP reply.  
4. The siaddr field of a DHCP or BOOTP reply.  
If only the sname or option 66 values are returned to the switch, a DNS  
server is needed to resolve the IP address of the TFTP server. After an IP  
address is assigned to the switch, if a hostname is not already assigned,  
Auto Configuration sends a DNS request for the corresponding hostname.  
Alternate TFTP Server and File Name  
On the DHCP Auto Configuration page, you can configure an alternate TFTP  
server and file name to be used when the server or file name provided by the  
DHCP server cannot be located. The following procedure is followed:  
1. The switch sends unicast messages to the TFTP server identified through  
DHCP, if provided.  
2. If the DHCP information is not provided or the server or file name cannot be  
found, then the server uses the alternate information, if configured.  
3. If the alternate information is not configured or the server or file name cannot be  
found, the switch sends broadcast TFTP requests for the file name in the DHCP  
message, if given. Otherwise, the switch enters default network configuration  
mode process described in the Default Network Configuration File section.  
Configuration File Download Details  
The switch first attempts to download a host-specific configuration file. If this is  
not possible, it downloads the configuration file <hostname>.cfg if Default  
Network Configuration Mode is enabled.  
Host-specific Configuration File  
The switch attempts to download the host specific configuration file whose name  
is specified as the boot file name in the reply from a DHCP/BOOTP server, or is  
configured as the Backup Configuration File for DHCP Auto Configuration. The  
switch makes three unicast TFTP requests for the specified boot file. If the unicast  
attempts fail, or if a TFTP server address was not provided, the switch makes  
three broadcast requests to any available TFTP server for the specified boot file.  
When the switch gets the configuration file, the configuration is validated for  
errors. If the validation is successful, the switch copies the configuration to the  
Startup Configuration file type, stores the configuration file name in non-volatile  
memory, and reboots the unit.  
Cisco Small Business SG200 Series 8-port Smart Switch  
64  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Administration  
File Management  
3
NOTE The switch requires the boot file name to have a .cfg extension.  
Default Network Configuration File  
If Default Network Configuration Mode is enabled, the switch downloads the  
configuration file <hostname>.cfg when any one of the following conditions  
occurs:  
A host specific configuration file is not specified or configured.  
A host specific configuration file does not exist on the TFTP server.  
A failure occurs during the download.  
NOTE The startup configuration file cannot be present on the switch. If the startup  
configuration file is present on the switch, this process is not initiated.  
To resolve the hostname in the configuration file, the switch first downloads  
fp-net.cfg from the TFTP server. The fp-net.cfg file is referred as the default  
network configuration file and contains one or more IP-address-to-host-name  
mappings. The switch determines the hostname from the mappings with its IP  
address. If there is no mapping, the switch uses reverse DNS lookup to discover  
the hostname.  
The following is a sample fp-net.cfg file.  
config  
...  
ip host switch_to_setup 192.168.1.10  
ip host another_switch 192.168.1.11  
... <other hostname definitions>  
exit  
When a hostname has been determined, the switch issues a TFTP request for a  
file named <hostname>.cfg, where <hostname> is the first eight characters of  
the switch hostname.  
The switch uses the IP address to do a DNS reverse name lookup. For example, if  
the switch IP address is 192.168.1.10, the hostname becomes switch_t.cfg (the  
first eight characters in the example above).  
The default switch name is derived as switch+last 6 digits of hex address. The  
mapping file should have the hostnames such as ip host switchD99FA5  
192.168.1.10. Then, the hostname learned for the <hostname.cfg> is  
switchD9.cfg for the switch having the IP address 192.168.1.10.  
If the switch is unable to map its IP address to a hostname, Auto Configuration  
sends TFTP requests for the default configuration file host.cfg.  
Cisco Small Business SG200 Series 8-port Smart Switch  
65  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Administration  
File Management  
3
When the switch gets the default configuration file, the configuration is validated  
for errors. If the validation is successful, then the switch copies the configuration to  
the Startup Configuration file type and reboots. In this case, the default  
configuration file name is not stored in the non-volatile memory.  
NOTE If the switch is unable to get the valid configuration file, then the process described  
above is repeated every 20 minutes until the switch gets a valid configuration file.  
The administrator can create a Startup Configuration file by manually saving the  
Running Configuration. The administrator can also disable Auto Configuration if  
desired.  
The following table summarizes the configuration files that can be downloaded,  
and the order in which they are sought.  
Order  
File Name  
Description  
Final File  
Sought  
Sought  
1
<bootfile>.cfg  
Host-specific configuration file,  
ending in a *.cfg file extension1  
Yes  
2
3
fp-net.cfg  
Default network configuration file  
No  
<hostname>.cfg  
Host-specific configuration file,  
associated with hostname  
Yes  
4
host.cfg  
Default configuration file  
Yes  
1. This file name might be learned through DHCP or manually configured, as described in  
An operator can terminate Auto Configuration at any time prior to the downloading  
of the file. This should be done when the switch is disconnected from the network,  
or if the required configuration files have not been set up on TFTP servers.  
When a configuration file is successfully downloaded and saved to the Startup  
Configuration file type, the switch logs a message with severity level Alert prior to  
rebooting.  
Cisco Small Business SG200 Series 8-port Smart Switch  
66  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Administration  
File Management  
3
Setting DHCP Auto Configuration  
You can use the DHCP Auto Configuration page to enable and disable the feature,  
configure TFTP server and file name settings, and view status information.  
When DHCP Auto Configuration is enabled, it will be in the Waiting for boot  
options state, until it receives the notification from the DHCP client. The DHCP  
client triggers the Auto Install process when it receives the IP address from the  
DHCP server, after which the status changes to Processing DHCP/BOOTP  
options, checking preconditions.  
The following messages might display:  
Waiting for boot options  
Processing DHCP/BOOTP options, checking preconditions  
Downloading tftp://<tftp address>/<filename>  
Applying downloaded configuration  
Waiting for restart timeout  
Saving the downloaded configuration  
Stopped  
AutoInstall is completed.  
AutoInstall process is terminated:File <filename>  
validation failed.  
AutoInstall process is terminated:Failed to save the  
downloaded configuration file<bootfile> to start-up  
configuration.  
AutoInstall process terminated:Startup config is created  
manually.  
AutoInstall process is terminated :Boot file matched  
with the last downloaded file.  
AutoInstall process is terminated:Failed to resolve the  
boot file name.  
Cisco Small Business SG200 Series 8-port Smart Switch  
67  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Administration  
File Management  
3
To configure DHCP Auto Configuration:  
STEP 1 Click Administration > File Management > DHCP Auto Configuration in the  
navigation window.  
STEP 2 Enter the parameters:  
Auto Configuration Via DHCP—Select Enable to enable this feature on the  
switch.  
Default Network Config Mode—Select Enable to have the switch  
download a default configuration file named fp-net.cfg when no host-  
specific file is found on the switch. See Default Network Configuration File  
for details.  
Alternate TFTP Server—Specify the IP address of a TFTP server to serve  
as a backup. An alternate TFTP server is used when unicast requests to the  
TFTP server specified in option 66 fails three times. (The length of the string  
cannot exceed 96 characters.)  
Alternate Configuration File—Specify an alternate configuration file name  
to serve as a backup. If no startup configuration file identified in DHCP option  
67, or if the specified file cannot be found on the TFTP server, Auto  
Configuration looks for the alternate file name. (The length of the string  
cannot exceed 32 characters.)  
Last Auto Configuration File Name—The configuration file name used the  
last time the Auto Configuration process executed. If a different file name is  
identified through DHCP, the file download process will begin.  
Current Status—The status of the Auto Configuration process. Possible  
values are AutoInstall Complete or In Progress.  
STEP 3 Click Apply. Your changes are saved to the Running Configuration.  
Cisco Small Business SG200 Series 8-port Smart Switch  
68  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Administration  
File Management  
3
Firmware Recovery Over HTTP  
The switch has a firmware recovery feature that enables the restoration of a valid  
image on the switch after a failed download. If the power goes down during an  
image download, the switch might not be able to boot. In this event, although the  
image is not usable, the boot loader file that loads the firmware image from Flash  
memory to RAM should continue to be functional. An HTTP server is embedded in  
the boot loader file, enabling the administrator to connect to the switch over a  
switch port and use a web browser to download and install a new firmware image.  
The switch enters the HTTP firmware recovery mode when the switch is booted  
and the boot loader cannot find a valid image in flash memory. In this mode, the  
boot loader sets the switch internal network port to the following static IP address:  
IP Address: 192.168.1.254  
Network Mask: 255.255.255.0  
Default Gateway: 192.168.1.1  
An HTTP server starts and listens for client connections on port 80.  
NOTE Firmware recovery can also be performed using the command line interface. Refer  
to the Cisco Small Business SF200E Command Line Reference.  
To use this feature to download a new firmware image:  
STEP 1 Directly connect a management PC to any switch port.  
STEP 2 Configure the IP address and mask on the management PC to be in the same  
subnet as the switch.  
NOTE: You can access the system across a network if the default gateway IP  
address is 192.168.1.1.  
STEP 3 Open a web browser and enter the IP address of the switch in the address bar  
(192.168.1.254).  
Cisco Small Business SG200 Series 8-port Smart Switch  
69  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Administration  
File Management  
3
NOTE: The HTTP firmware recovery features supports the following browsers:  
Firefox 3.0 and later versions  
Internet Explorer 6 and later versions  
A Firmware Recovery page displays. No authentication is required.  
The web page displays the PIC VID (product ID and vendor ID), serial number, and  
MAC Address of the switch.  
STEP 4 Select Browse and select a valid firmware image to download.  
A progress bar appears while the file is downloading. The following message  
appears upon a successful download:  
100% Complete  
File downloaded successfully. Please wait while the file is being written to  
flash.  
The file selected by administrator is downloaded to RAM and is validated for  
following conditions:  
The CRC of the file is good.  
The STK file is built for this platform.  
The STK file size is within the partition limits (4.5 MB is reserved for this file).  
If these conditions are met, the file is written to Flash memory and the system is  
rebooted using the new firmware.  
If any of these checks fail, the image is not written to Flash memory and the  
recovery process is stopped. You can restart the recovery process with a correct  
image file.  
If the transfer is aborted because the browser window is refreshed or closed, the  
session is cleared and the session times out immediately. If the transfer is aborted  
because the network is unreachable, the session times out after 45 seconds. After  
the session times out, you can begin the recovery process again.  
Cisco Small Business SG200 Series 8-port Smart Switch  
70  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Administration  
File Management  
3
Downloading an Image or Boot Code File From the System  
Boot Prompt  
You can download and install a new image or boot code file at the system boot  
prompt using the TFTP and XMODEM protocols. This process may be necessary  
when the application software does not execute due to a corrupted software  
image or boot code file and, as a result, you cannot access the CLI or web-based  
interface utilities for downloading and installing new software.  
If the switch is connected to a network, you can obtain IP information for the switch  
via DHCP, and then use TFTP to download the file.  
If no network connection is available, and the switch is connected through its serial  
console port to a management station, you can use the XMODEM protocol to  
download the file.  
NOTE This process requires a management system that is connected to the serial  
console port on the switch and has a terminal emulation program, such as Tera Term  
or HyperTerminal. Configure the utility with the following parameters:  
115200 bits per second  
8 data bits  
no parity  
1 stop bit  
no flow control  
See your product Quick Start Guide for more information on setting up the  
console port connection.  
Downloading an Image or Boot Code File Using TFTP  
To download a software image or boot code file using TFTP at the boot prompt:  
STEP 1 Using a terminal emulation program, open a serial connection between the switch  
and the management system connected to the switch console port.  
STEP 2 Physically connect switch port e1 to the network.  
STEP 3 Power up the switch.  
STEP 4 Stop the firmware load by pressing and holding <Ctrl> + C as the switch boots up.  
The boot-level command prompt displays:  
CFE>  
Cisco Small Business SG200 Series 8-port Smart Switch  
71  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Administration  
File Management  
3
STEP 5 Enter the command to have an IP address assigned to the port from a DHCP server  
on the attached network:  
CFE> ifconfig eth0 -auto  
When the switch receives a DHCP reply, the IP information displays on the  
terminal.  
STEP 6 Enter the command to download an image file to Flash:  
CFE>flash server-ipaddr:image-filename flash0.os  
Or, enter the command to download a boot code file:  
CFE> flashipaddr:bootcode-filename flash0.boot  
Replace ipaddr with the IP address of the system where the file resides, and  
replace image-filename or bootcode-filename with the actual image or  
boot code filename.  
WARNING! Make sure that the switch is connected to an uninterrupted power  
supply during a boot code upgrade. This process might take 10–20 seconds.  
When the download is complete, the switch copies the image or boot code file  
into Flash memory.  
STEP 7 Enter the command to restart the switch to boot it with new software:  
CFE>reset -sysreset  
NOTE: You can verify the boot code or image version by viewing the System  
Summary page in the web-based switch configuration utility. Or, from the  
command line interface, you can enter the show sysinfocommand.  
Downloading an Image or Boot Code File Using XMODEM  
To download a software image or boot code file using XMODEM at the boot  
prompt:  
STEP 1 Using a terminal emulation program, open a serial connection between the switch  
and the management system connected to the switch console port.  
STEP 2 Power up the switch.  
Cisco Small Business SG200 Series 8-port Smart Switch  
72  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Administration  
File Management  
3
STEP 3 Stop the control at boot code by pressing and holding <Ctrl> + C continuously as  
the switch boots up, until the following prompt displays:  
CFE>  
STEP 4 Enter the command to download a software image:  
CFE>flash uart0 flash0.os  
Or, enter the command to download a boot code file:  
CFE>flash uart0 flash0.boot  
WARNING! Make sure that the switch is connected to an uninterrupted power  
supply during a boot code upgrade. This process might take 10–20 seconds.  
The switch waits for a file to be sent from the management station.  
STEP 5 In the terminal emulation software, select the file and begin the transfer.  
For example, in Tera Term, click File > Transfer > XMODEM > Send, and then  
browse to select the file.  
When the download is complete, the switch burns the image or boot code file into  
Flash memory.  
STEP 6 Enter the command to restart the switch to boot it with new software:  
CFE>reset -sysreset  
NOTE: You can verify the boot code or image version by viewing the System  
Summary page in the web-based switch configuration utility. Or, from the  
command line interface, you can enter the show sysinfocommand.  
Cisco Small Business SG200 Series 8-port Smart Switch  
73  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Administration  
Rebooting the Switch  
3
Rebooting the Switch  
Use the Reboot page reboot the switch. To reboot the switch:  
STEP 1 Click Administration > Reboot in the navigation window.  
STEP 2 Select one of the following options:  
Reboot—Reboots the switch using the latest save configuration.  
Reboot to Factory Default—Reboots the switch using with the factory  
default configuration file. Any customized settings are lost.  
A window appears to enable you to confirm or cancel the reboot. The current  
management session might be terminated.  
STEP 3 Confirm or cancel the reboot.  
Pinging Hosts  
Use the Ping page to send a Ping request from the switch to a specified IP  
address. You can use this feature to check whether the switch can communicate  
with a particular network host.  
To ping a network host:  
STEP 1 Click Administration > Ping in the navigation window.  
STEP 2 Select IPv4 or IPv6 as the Address Type.  
Cisco Small Business SG200 Series 8-port Smart Switch  
74  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Administration  
Configuring Control Packet Forwarding  
3
STEP 3 For an IPv4 address, enter the following parameters:  
IP Address/Hostname—Enter the IP address or the hostname of the station  
you want the switch to ping.  
Count—Specify the number of pings to send.  
Interval—Specify the number of seconds between pings sent.  
Datagram Size—Specify the data size of the ping packet to send.  
For an IPv6 address, enter the following parameters:  
Ping Type—Select Global to ping an address outside the local subnet.  
Select Link Local to ping an address on the local subnet.  
IPv6 Address/Hostname—(Global addresses only) Enter the 128-bit global  
address.  
IPv6 Link-Local Address—(Link-local addresses only) Enter the link local  
address if the address is on the same subnet as the switch.  
Datagram Size—Specify the data size of the ping packet to send (between  
48 and 2048 bytes).  
STEP 4 Click Apply to send the ping. You can view the status in the Ping window.  
Configuring Control Packet Forwarding  
You can use the Control Packet Forwarding page to configure how the switch  
handles packets of the following protocol types:  
CDP—The Cisco Discovery Protocol (CDP), which is supported on many  
types of Cisco networking equipment. CDP enables directly connected  
devices to share information such as their IP addresses, capabilities, and  
software versions. Although the switch does not itself support CDP, it can  
forward CDP packets on behalf of connected devices within a VLAN.  
Dot1X—The IEEE 802.1X protocol defines how Extensible Authentication  
Protocol (EAP) packets are encapsulated over a LAN. Dot1X provides a way  
to authenticate users and allow or deny them access to services made  
available by switch ports. See 802.1X for information on configuring the  
Dot1X feature on the switch.  
Cisco Small Business SG200 Series 8-port Smart Switch  
75  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Administration  
Diagnostics  
3
LLDP—Network devices use the Link Layer Discovery Protocol to advertise  
their capabilities to other devices. See LLDP-MED for information on  
configuring the LLDP feature on the switch.  
To configure control packet forwarding:  
STEP 1 Click Administration > Control Packet Forwarding in the navigation window.  
STEP 2 Select the protocol you want to configure (CDP, LLPD, or DOT1x).  
STEP 3 Select the action that a port will take when received packets of the specified type:  
Drop—All packets of the selected type are dropped.  
Forward—All packets of the selected type are forwarded within the  
specified VLAN. This is the default action for CDP packets.  
Terminate—The packet is accepted and processed on the switch. This is  
the default action for LLDP and DOT1X packets and is not available for CDP  
packets.  
STEP 4 Click Apply. Your changes are saved to the Running Configuration.  
Diagnostics  
You can use the diagnostics pages to perform virtual cable tests for copper and  
fiber optics cables, set up a diagnostic monitor for a port or VLAN, and to view  
CPU utilization data.  
See the following topics for more information on the configuration pages available  
in the Administration > Diagnostics menu:  
Cisco Small Business SG200 Series 8-port Smart Switch  
76  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Administration  
Diagnostics  
3
Testing Copper Ports  
Use the Copper Ports page to perform tests on copper cables. These physical  
layer diagnostics can be used to help determine where in the cable a break might  
exist.  
The Copper Ports Table lists each port and the following data, which it learned  
through the most recent test (default data appears if the port has not been tested):  
Test Result—Results of the most recent cable test. Possible values are:  
-
-
-
-
-
Normal—Cable is working correctly.  
Open—Cable is disconnected or the connector is faulty.  
Short—Cable has an electrical short.  
Untested—No test has been performed.  
Cable status test failed—Cable status could not be determined by the  
test. The cable might be working.  
Distance to Fault—Distance in meters from the port where the cable error,  
if any, was detected in the most recent cable test.  
Last Update—Last time the port was tested.  
Cable Length—Length of the cable in meters.  
To initiate a copper port test:  
STEP 1 Click Administration > Diagnostics > Copper Ports in the navigation window.  
STEP 2 Select a port and click Test.  
If the port has an active link while a cable test is run, the link might go down for the  
duration of the test. It might take several seconds to run the test. When complete, a  
window appears with the test results.  
Cisco Small Business SG200 Series 8-port Smart Switch  
77  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Administration  
Diagnostics  
3
Configuring Port Mirroring  
Use the port mirroring feature to send network traffic on a port copied to another  
port for analysis by a network analyzer.  
A mirroring session consists of a destination probe port and at least one source  
port. A mirror copy of the traffic on the source port(s) being probed are  
transmitted from the source port to the destination probe port. A network analyzer  
can be connected to a destination probe port to analyze network traffic.  
A port configured as a destination probe port acts as a mirroring port as long as  
the session is operationally active. When the session is not active, the port  
transmits and receives traffic based on the other configuration parameters.  
NOTE When a port is configured as a probe port, the switch does not forward or receive  
any traffic or respond to a ping.  
To d i s p l ay t h e Port and VLAN Mirroring page, click Administration > Diagnostics  
> Port Mirroring in the navigation window.  
Four mirroring sessions are available for configuration and are disabled by default.  
The Port Mirroring Session Table displays the following fields for each session:  
Session ID—A monitoring session ID number.  
Admin Mode—Indicates whether the port mirroring session is enabled or  
disabled.  
Destination InterfaceTo enable this feature, select it and choose the  
port to where the traffic on the source port is mirrored to the destination  
probe port.  
Source Interface—List of the source interfaces selected to participate in  
this mirroring session.  
The Port Mirroring Source Interface Table lists the source interfaces assigned to  
each session. You can select Filter and select a Session ID to display data for only  
one session.  
To set up port mirroring, you first assign source interfaces to a session. Then, you  
define a destination interface and enable the session. A session is operationally  
active only when the source and destination interfaces are configured and the  
administrative mode is enabled.  
Cisco Small Business SG200 Series 8-port Smart Switch  
78  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Administration  
Diagnostics  
3
To configure a mirroring session:  
STEP 1 In the Port Mirroring Source Interface Table, click Add.  
STEP 2 Select a Session ID.  
STEP 3 Select the Source Interface and the type of traffic to be mirrored.  
STEP 4 By using the Type radio button, specify the direction of the traffic at the source  
interface that is to be monitored:  
Rx Only—Incoming traffic  
Tx Only—Outgoing traffic  
Tx and Rx—Both incoming and outgoing traffic  
STEP 5 Click Apply. Your changes are saved to the Running Configuration.  
You can repeat the process to assign multiple Source Interfaces to the same  
session. However, a source interface can be used in only one active session at a  
time.  
STEP 6 In the Port Mirroring Session Table, select the session to activate and click Edit.  
STEP 7 For the Admin Mode, select Enable. (Deselecting the Admin Mode check box  
retains the session configuration but disables it.)  
STEP 8 For the Destination Interface, select Enable and select a Destination Interface port  
to mirror the data.  
!
CAUTION When a port is configured as a destination probe port, the switch does not forward  
or receive any traffic on that port and it does not respond to any pings received on  
that port. All the previous configuration parameters on that port are cleared and the  
port must be reconfigured when mirroring is removed from the port configuration.  
Select Reset Session to clear any configuration parameters applied during this  
session.  
STEP 9 Click Apply and then click Close. The probe session begins.  
NOTE To end a probe session, select the session in the Port Mirroring Session Table and  
click Edit. Clear the Admin Mode checkbox, click Apply, and then click Close.  
Cisco Small Business SG200 Series 8-port Smart Switch  
79  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Administration  
Enabling Bonjour  
3
To clear the current configuration for a session, select the session and click Edit.  
Then select Enable for Reset Session field.  
CPU/Memory Utilization  
Use the CPU/Memory Utilization page to monitor CPU and memory usage. To  
display this page, click Administration > Diagnostics > CPU/Memory Utilization  
in the navigation window.  
The page displays the following data:  
Refresh Rate—Specify that the page refresh with the latest data every 15,  
30, or 60 seconds, or leave the default as No Refresh.  
CPU Utilization Report—The utilization percentage for 5 second, 1 minute,  
and 5 minute intervals.  
Memory Utilization Report—The following data is reported:  
-
-
-
Allocated Memory—Amount of memory available to the operating  
system (OS).  
Free Memory—Amount of memory available to the OS that is currently  
free.  
Total Memory—Total system memory, which includes the Allocated  
Memory, plus free memory, plus memory reserved for use by code and  
data sections of the software image.  
Enabling Bonjour  
Bonjour enables the switch and the services enabled by the administrator to be  
discovered by using multicast DNS (mDNS). (Use the Administration >  
Management Services page to enable or disable the switch services.) Bonjour  
advertises switch services to the network and answers queries for the service  
types it supports, simplifying network configuration in small business  
environments.  
Bonjour is enabled by default and runs on the management VLAN. Bonjour  
Discovery can only be enabled globally, not on a per-port or per- VLAN basis.  
The switch advertises the following service types:  
Cisco Small Business SG200 Series 8-port Smart Switch  
80  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Administration  
LLDP-MED  
3
Cisco-specific device description (csco-sb)—This service enables clients  
to discover Cisco switches and other products deployed in small business  
networks.  
Management user interfaces—This service identifies the management  
interface available on the switch (HTTP).  
When a Bonjour-enabled switch is attached to a network, any Bonjour client can  
discover and get access to the management interface without prior configuration.  
A system administrator can use an installed Internet Explorer plug-in to discover  
the switch. The web-based switch configuration utility shows up as a tab in the  
browser.  
When Bonjour Discovery and IGMP are both enabled, the IP Multicast address of  
Bonjour is displayed on the IP Multicast Group Address Page. When Bonjour  
Discovery is disabled, the switch stops service type advertisements and does not  
respond. Bonjour works in both IPv4 and IPv6 networks.  
To enable the switch to be discovered through Bonjour:  
STEP 1 Click Administration > Discovery - Bonjour in the navigation window.  
STEP 2 Select Enable.  
STEP 3 Click Apply.  
LLDP-MED  
The IEEE 802.1AB standard, Link Layer Discovery Protocol (LLDP), describes a  
method by which stations residing on a LAN advertise identification information,  
capabilities, and physical descriptions. The information is exchanged in LLDP data  
units (LLDPDUs) which comprise type-length-value (TLV) structures. Various TLVs  
might be included in LLDPDUs, depending on the information that the  
administrator configures the port to advertise.  
Information learned through LLDPDUs is stored in MIBs, and the information might  
be accessible by a network management system (NMS) such as SNMP. This  
framework is extensible and allows advanced utilization in areas such as VoIP  
networks.  
NOTE LLDPDUs only communicate information; they do not automatically configure the  
switch.  
Cisco Small Business SG200 Series 8-port Smart Switch  
81  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Administration  
LLDP-MED  
3
The switch supports the LLDP Media Endpoint Discovery (LLDP-MED) extensions  
to the LLDP protocol. LLDP-MED enables auto-discovery of LAN policies, device  
location, and other device characteristics, and automates management of Power-  
over-Ethernet (PoE) endpoints.  
See the following topics for more information on the configuration pages available  
in the Administration > Discovery - LLDP menu:  
Configuring Global LLDP-MED Properties  
Use the LLDP MED Properties page to specify global parameters for this feature.  
To configure global LLDP-MED properties:  
STEP 1 Click Administration > Discovery - LLDP-MED > Properties in the navigation  
window.  
The LLDP-MED specification defines two primary device classes: Network  
Connectivity devices and Endpoint devices. As indicated in the Device Class field,  
the switch is classified as a Network Connectivity device.  
STEP 2 For Asset ID, enter the asset ID for the switch, advertised in Inventory TLVs.  
STEP 3 Specify the Location Parameters to identify the physical location of the switch:  
Subtype—Select one of the following options to configure how the switch  
location is identified in TLVs:  
-
-
-
Coordinate Based—Switch location is identified using GPS coordinates  
in hexadecimal format.  
Civic Address—Switch location is identified using a geographic  
description of the location, such as city, street name, and building name.  
ELIN—Switch location is identified using the Emergency Location  
Identification Number (ELIN) of the switch.  
Cisco Small Business SG200 Series 8-port Smart Switch  
82  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Administration  
LLDP-MED  
3
Coordinates—Switch GPS coordinates in hexadecimal format.  
ELIN Address—The ELIN number.  
Country—Country where the city is located. This is a two-character code as  
defined by ISO 3166.  
City—City where the street is located.  
Street—Street where the building is located.  
Building—Building in which the switch is located.  
NOTE: The City, Street, and Building fields share the maximum character  
limitation; i.e., an entry in one field reduces the maximum allowable characters  
in the others. The maximum combine length of the city, street, and building fields  
is 246 characters. The characters ', ", %, and ? are not supported.  
STEP 4 Click Apply. Your changes are saved to the Running Configuration.  
Configuring LLDP-MED on a Port  
The LLDP for Media Endpoint Devices (LLDP-MED) protocol provides extensions  
to the LLDP standard for network configuration and policy, device location, Power-  
over-Ethernet management, and inventory management.  
Use the LLDP-MED Port Settings page to view and configure LLDP-MED  
operation on ports.  
To configure these settings on a port:  
STEP 1 Click Administration > Discovery - LLDP-MED > LLDP-MED Port Settings in the  
navigation window.  
Each entry in the LLDP-MED Port Settings Table displays the LLDP-MED  
configuration for a port.  
STEP 2 Select a port to configure and click Edit.  
STEP 3 Specify the following for the selected port:  
LLDP-MED Status—Select to enable LLDP-MED operation on the port.  
Configuration Notification—Select to enable the switch to send  
notifications when there are topology changes on the network.  
Cisco Small Business SG200 Series 8-port Smart Switch  
83  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Administration  
LLDP-MED  
3
STEP 4 Select the Available TLVs that you want the port to include in LLDP  
advertisements:  
Network Policy—VLAN ID, the 802.1p class-of-service value, and the  
Differentiated Services Code Point (DSCP) value. This information is used to  
implement the Voice VLAN feature (see Voice and Media).  
Location—This value could include the hexadecimal GPS location  
coordinates for the switch, the civic address, or the ELIN address depending  
upon what is configured in Configuring Global LLDP-MED Properties.  
PSE—Indicates whether the port advertises itself as Power Sourcing  
Equipment capable of providing power to a connected Power-over Ethernet  
device. This option appears only on switches that include the PoE features.  
Inventory—Hardware and software version information.  
System Capabilities—Identifies the basic functionality of the switch such  
as bridging.  
NOTE The Application Type is included in the Network Policy TLV.  
Application types include Voice, Voice Signaling, Guest Voice, Guest Voice  
Signaling, Softphone Voice, Video Conferencing, Streaming Video, and  
Video Signaling. These Network Policies can be added to interfaces by  
using the VLAN Management > Voice and Media > Media VLAN page.  
STEP 5 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
NOTE You can click Configure Network Policy to display the Media VLAN page. (You can  
also click VLAN Management > Voice and Media > Media VLAN in the navigation  
window.) This page enables you to assign LLDP-MED applications to VLANs and  
configure priority settings for associated traffic.  
Cisco Small Business SG200 Series 8-port Smart Switch  
84  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Administration  
LLDP-MED  
3
LLDP-MED Port Status Details  
The LLDP-MED Port Status Details page displays the LLDP-MED configuration for  
all ports on which the feature is enabled. To display this page, click  
Administration > Discovery - LLDP-MED > LLDP-MED Port Status Details in  
the navigation window.  
Select a port from the Port list. The Network Policies Table shows the fields for  
each service or policy advertised through LLDP:  
Media Policy Application Type—Type of service, such as Voice, associated  
with the LLDP network policy.  
VLAN ID—VLAN ID associated with the network policy.  
Priority—802.1p class-of-service value associated with the network policy.  
DSCP—DSCP value for the network policy.  
Tagged—Network policy is defined for tagged VLANs.  
The following switch parameters are advertised in Inventory TLVs.  
Hardware Revision—Switch hardware revision ID.  
Firmware Revision—Switch firmware revision number.  
Software Revision—Switch software revision number.  
Serial Number—Switch serial number.  
Manufacturer Name—Switch manufacturer name.  
Model Name—Switch model name.  
Asset ID—LLDP-MED asset ID for the switch.  
The following switch parameters are advertised in System TLVs.  
Chassis ID—The hardware address of the switch.  
Chassis ID Subtype—The type of hardware address.  
System Description—A preconfigured system description.  
System Name—The user-configured hostname (see the System Settings  
page).  
Management Address SubType—The protocol version for the  
management IP address.  
Cisco Small Business SG200 Series 8-port Smart Switch  
85  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Administration  
LLDP-MED  
3
Management Address—The management interface IP address (see the  
IPv4 Interface page or the IPv6 Interface page).  
Port ID SubType—The type of the port identifier.  
Port ID—The port identifier.  
Port Description—The port description.  
System Capabilities Enabled—The capabilities that are enabled on the  
switch.  
System Capabilities Supported—The capabilities that are currently  
advertised as supported by the switch.  
The following switch parameters are advertised in Location TLVs.  
Subtype—The supported type of location information (civic, ELIN, or  
coordinate-based).  
Coordinates—Switch GPS coordinates in hexadecimal format, if  
coordinate-based location information type is used.  
ELIN Address—The ELIN number, if this location information type is used.  
Country—Country where the city is located, if the civic location information  
type is used.  
City—City where the street is located, if the civic location information type  
is used.  
Street—Street where the building is located, if the civic location information  
type is used.  
Building—Building in which the switch is located, if the civic location  
information type is used.  
Cisco Small Business SG200 Series 8-port Smart Switch  
86  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Administration  
LLDP-MED  
3
LLDP-MED Neighbor Information  
The Neighbor Information page displays information received from other LLDP-  
MED-capable devices in the network. To display this page, click Administration >  
Discovery - LLDP-MED > Neighbor Information in the navigation window.  
The Neighbor Information Table displays the following fields for each LLDP  
neighbor device for which an advertisement has been received:  
Local Port—Port number of the switch where the LLDP advertisement was  
received.  
Remote ID—An internal identifier to uniquely identify each Neighbor.  
Remote Port ID—Name of the port through which the neighbor device sent  
the advertisement.  
Device Class—Advertised class of the remote device.  
You can select an entry and click Details to display additional information from the  
LLDP-MED advertisement from the neighbor.  
The Neighbor Information—Details page displays the following information:  
MED Capabilities  
Capabilities Supported—Advertised capabilities of the device.  
Capabilities Enabled—Advertised capabilities that are enabled on the  
device.  
Device Class—Advertised class of the remote device.  
Network Policies  
Media Policy Application Type—Type of service, such as voice, associated  
with the LLDP network policy.  
VLAN ID—VLAN ID associated with the network policy.  
Priority—802.1p class-of-service value associated with the network policy.  
DSCP—DSCP value for the network policy.  
Unknown—Neither the 802.1p value nor the DSCP value is configured for  
this Network Policy.  
Tagged—network policy is defined for tagged VLANs.  
Cisco Small Business SG200 Series 8-port Smart Switch  
87  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Administration  
LLDP-MED  
3
Inventory  
Hardware Revision—Switch hardware revision ID.  
Firmware Revision—Switch firmware revision number.  
Software Revision—Switch software revision number.  
Manufacturer Name—Switch manufacturer name.  
Model Name—Switch model name.  
Asset ID—LLDP-MED asset ID for the switch.  
Location  
Subtype—Select one of the following options to configure how the switch  
location is identified in TLVs:  
-
-
-
Coordinate Based—Switch location is identified by using GPS  
coordinates in hexadecimal format.  
Civic Address—Switch location is identified by using a geographic  
description of the location, such as city, street name, and building name.  
ELIN—Switch location is identified by using the Emergency Location  
Identification Number of the switch.  
Location Information—Switch location information, in the format specified  
by the Subtype field.  
Extended PoE  
PoE Device Type—If PoE functionality is advertised, this field indicates  
whether the device is a Powered Device (PD) or Power Sourcing Equipment  
(PSE).  
Extended PoE PD  
If the device is powered by PoE, the following properties can be advertised:  
PoE Power Value—Power in watts requested by the device.  
PoE Power Source—Indicates how the powered device receives power:  
-
-
Primary—A power supply is connected directly to the device.  
Backup—The device receives power from a PoE power sourcing  
equipment.  
Cisco Small Business SG200 Series 8-port Smart Switch  
88  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Administration  
Configuring DHCP Client Vendor Options  
3
PoE Power Priority—Displays High, Low, or Critical to indicate how the  
port is prioritized when there is less PoE power to deliver than requested by  
all powered devices.  
Configuring DHCP Client Vendor Options  
You can configure the DHCP client functionality on the switch to include vendor  
information in its DHCP requests (DHCP option 60). A DHCP server might use  
vendor information to differentiate between clients based on the identified  
hardware type or functionality.  
To configure DHCP vendor option string:  
STEP 1 Click Administration > DHCP Options in the navigation window.  
In addition to the vendor option and string, the page displays the format that the  
switch uses when obtaining its timezone information from a DHCP server. To  
configure the switch to acquire its timezone from DHCP, see Time Settings. If  
timezone information has been received, it displays the information. The Timezone  
Info Received field displays the information received, or displays False if no  
information has been received.  
STEP 2 Select Enable for the Vendor Option.  
STEP 3 Enter a value in the Vendor Option String text box.  
STEP 4 Click Apply. Your changes are saved to the Running Configuration.  
Cisco Small Business SG200 Series 8-port Smart Switch  
89  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4
Port Management  
This chapter describes how to configure switch port settings, combine ports into  
link aggregation groups, and configure port power features.  
The following topics are included:  
Configuring Port Settings  
The Port Settings page enables you to administratively enable and disable ports  
and to configure autonegotiation of port speed and duplex mode. You can also use  
this page to configure flow control on the port.  
To configure port settings:  
STEP 1 Click Port Management > Port Settings in the navigation window.  
STEP 2 Select the interface to configure, and then click Edit.  
STEP 3 Specify the following for the selected port:  
Administrative Status—Select Up to enable the port or Down to disable it.  
Auto Negotiation—Select Enable to allow the switch autonegotiate the port  
speed and duplex mode with the connected device. If Autonegotiation is  
enabled, the Administrative Port Speed and Duplex Mode fields are not  
editable.  
Administrative Port Speed—If Auto Negotiation is disabled, select whether  
the port is capable of 10 Mbit/s or 100 Mbit/s operation.  
Cisco Small Business SG200 Series 8-port Smart Switch  
90  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Port Management  
Configuring Port Settings  
4
Administrative Duplex Mode—If Auto Negotiation is disabled, select Half  
for half-duplex or Full for full-duplex operation.  
Admin Advertisement—If Autonegotiation is enabled, select the highest  
port speed and duplex setting that you want the port to negotiate. If you  
select Max Capacity, the port autonegotiates up to the highest port speed  
and duplex setting supported by hardware.  
Flow Control—Select to enable IEEE 802.3x flow control. Flow control  
reduces data loss when the port cannot keep up with the number of frames  
being switched. When enabled, the switch can send a PAUSE frame to stop  
traffic on a port if the amount of memory used by packets on the port  
exceeds a preconfigured threshold. The paused port does not forward  
packets for the period of time specified in the PAUSE frame. When the  
PAUSE frame time elapses or memory utilization falls below a specified low  
threshold, the switch enables the port to again transmit frames. When the  
mode is set to half–duplex, back pressure is exerted; however, we  
recommend that Flow Control be enabled.  
Member in LAG—Indicates whether the port is a member of a Link  
Aggregation Group. See Link Aggregation for information on configuring  
LAGs.  
MTU—Specify the maximum transmission unit size in bytes. The default  
MTU is 1518 and the range is between 1518 and bytes.  
STEP 4 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
Cisco Small Business SG200 Series 8-port Smart Switch  
91  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Port Management  
Link Aggregation  
4
Link Aggregation  
Link Aggregation allows one or more full-duplex Ethernet links to be aggregated  
together to form a Link Aggregation Group (LAG). The switch treats the LAG as if it  
is a single physical port, with improved fault tolerance and load- sharing capability.  
A LAG interface can be either static or dynamic:  
Static LAG—Ports are assigned to a LAG directly by the administrator. The  
ports remain dedicated LAG members until configured otherwise.  
Dynamic LAG—A dynamic LAG is configured with one or more candidate  
ports. The LAG is formed by exchanging Link Aggregation Control Protocol  
Data Units with the remote device connecting to the candidate ports. When  
formed, the LAG might include only a subset of the eligible ports,  
depending on the port number limitations for LAGs and other factors.  
Candidate ports that are not selected as active member ports of a LAG are  
standby ports. A standby port may be selected as an active member when  
an active port in the same LAG fails.  
The following topics provide additional information on the configuration pages  
available in the Port Management > Link Aggregation menu:  
Configuring LAGs  
The switch supports up to 4 LAGs, with 8 ports per LAG. Use the LAG  
Management page to assign ports to LAGs and LACPs.  
To display this page, click Port Management > Link Aggregation > LAG  
Management in the navigation window.  
Four dynamic LAGs are preconfigured by default named ch1 through ch4. They  
have no port members and are disabled.  
You can add or remove ports to or from a LAG without disrupting traffic on the  
LAG.  
Cisco Small Business SG200 Series 8-port Smart Switch  
92  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Port Management  
Link Aggregation  
4
LAGs can be assigned membership in VLANs; however, individual ports lose their  
individual VLAN memberships when they become LAG members. When a port is  
removed from a LAG, it rejoins the VLANs that it previously belong to as specified  
in the startup configuration.  
To configure a LAG:  
STEP 1 Select a LAG to configure, and then click Edit.  
STEP 2 Specify the following for the selected LAG:  
LAG Name—Enter up to 15 alphanumeric characters to identify the LAG.  
Type—Select Static to manually assign ports to the LAG. Select Dynamic to  
enable the ports to exchange LACPDUs to dynamically form the LAG.  
Port List/LAG Member—To add or remove ports from a static LAG, select  
each port and click the left or right arrow to move it between the Port and  
LAG Member lists.  
STEP 3 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
Configuring LAG Settings  
You can use the LAG Settings page to administratively enable or disable a LAG  
and configure load balancing settings.  
To configure LAG settings:  
STEP 1 Click Port Management > Link Aggregation > LAG Settings in the navigation  
window.  
The LAG Settings Table lists each available LAG.  
STEP 2 Select a LAG to configure, and then click Edit.  
STEP 3 Specify the following for the selected LAG:  
Administrative Status—Select Up or Down to administratively enable or  
disable the LAG. When a LAG is disabled, its member ports operate as  
standalone physical ports.  
Cisco Small Business SG200 Series 8-port Smart Switch  
93  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Port Management  
Link Aggregation  
4
Load Balance Algorithm—Select one of the options to enable the switch to  
load-balance outgoing packets among member ports of a LAG. The switch  
selects one of the links in the channel for transmitting specific packets. The  
switch prioritizes each criteria for load balancing in the order listed in the  
option. The options are:  
-
Src/Dest MAC, VLAN, EType, incoming port—Source and destination  
MAC addresses, the VLAN membership, the Ethertype field, and the port  
on which the packet was received.  
-
Src/Dest IP and TCP/UDP Port Fields—Source and destination IP  
address and the TCP or UDP port number in the IP packet.  
If the IP packet option is selected, non-IP packets received on the port are  
balanced using the Src and Dest MAC address.  
MTU—Specify the maximum transmission unit size in bytes. The default  
MTU is 1518 and the range is between 1518 and bytes.  
STEP 4 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
Configuring LACP  
The switch uses the Link Aggregation Control Protocol (LACP) to automate the  
formation of dynamic LAGs. LACP-enabled ports send protocol data units  
(LACPDUs) to detect each other on a network and negotiate a LAG.  
Use the LACP page to view and configure protocol operation.  
To configure LACP settings on individual ports:  
STEP 1 Click Port Management > Link Aggregation > LACP in the navigation window.  
The LACP Interface Table displays the following information for each port:  
LACP Mode—The administrative status of LACP mode (Enabled or  
Disabled)  
The table displays the following information for the port when the port is the Actor  
(local) port:  
System Priority—A nonconfigurable system priority assigned to the  
switch.  
Cisco Small Business SG200 Series 8-port Smart Switch  
94  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Port Management  
Link Aggregation  
4
Admin Key—A number that determines the dynamic LAG(s) that the  
interface can join. All interfaces in a dynamic LAG must share the same  
admin key.  
Port Priority—A nonconfigurable priority assigned to the port.  
LACP Aggregation—The port mode with respect to link aggregation. This  
field is not configurable. Possible values are:  
-
-
Aggregate—The port is participating in link aggregation.  
Individual—The port is not participating in link aggregation and is  
functioning as an individual standalone port.  
LACP Passive—This field is always set to Active for all ports and is not  
configurable. It indicates that the port will continue to transmit LACPDUs  
after the LACPDU timeout has elapsed, regardless of the status of the link  
partner.  
LACP Timeout—The time after which an LACPDU is no longer valid (Long  
or Short).  
The Table also displays the LACP Aggregation, LACP Passive, and LACP timeout  
values for the port when the port is the Partner (remote) port.  
To edit the LACP settings:  
STEP 1 Select the port to configure and click Edit.  
STEP 2 Configure the following settings for the selected port:  
Mode—Check the box to enable LACP on the port.  
Actor Timeout—Information from the actor is no longer valid after the  
timeout period elapses.  
-
-
Short—Short LACP timeout is 3 times the short periodic timer to  
transmit LACP packets. The default Short LACP timeout is 3 seconds.  
Long—Long LACP timeout is 3 times the long periodic timer to transmit  
LACP packets. The default Long LACP timeout is 90 seconds.  
Partner Timeout—Information from the partner is no longer valid after the  
timeout period elapses.  
-
Short—Short LACP timeout is 3 times the short periodic timer to  
transmit LACP packets. The default Short LACP timeout is 3 seconds.  
Cisco Small Business SG200 Series 8-port Smart Switch  
95  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Port Management  
Configuring PoE  
4
-
Long—Long LACP timeout is 3 times the long periodic timer to transmit  
LACP packets. The default Long LACP timeout is 90 seconds.  
STEP 3 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
Configuring PoE  
On the SF200E-24P switch, ports 1–6 and 1318 can operate as Power-over-  
Ethernet (PoE) power-sourcing equipment (PSE). PSE ports can provide power to  
connected PoE Powered Devices (PD).  
On switches with PSE ports, the following topics provide information on the  
configuration pages available in the Port Management > PoE menu:  
NOTE These configuration pages do not display on switches that do not support PSE  
functionality.  
Configuring PoE Properties  
You can use the Properties page to configure whether the switch generates trap  
messages under certain conditions and to view current power settings.  
To configure PoE properties:  
STEP 1 Click Port Management > PoE > Properties in the navigating window.  
STEP 2 Set the following parameters:  
Power Trap Threshold—Specify a percentage of total available system  
power. When the requested power on PoE ports exceeds the threshold, a  
trap is generated to the log.  
Cisco Small Business SG200 Series 8-port Smart Switch  
96  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Port Management  
Configuring PoE  
4
Power Management Mode—Select how the switch prioritizes the power  
that it provides to multiple ports:  
-
Static with Port Priority—Static with priority power management. This  
algorithm pre-allocates power based on the configured power limit and  
the priority of the port.  
-
Dynamic with Port Priority—Dynamic with priority power  
management. This algorithm supplies power to devices as long as the  
consumption is within the configured limit and priority. There is no pre-  
allocation of power.  
In both modes, a port with a higher port priority is given preference when the  
switch supplies power to multiple ports. If two or more port priorities are  
equal, the port with the lower port number is given preference.  
Reset Mode—Select Enable to enable the switch initialize all PoE ports state  
machines.  
STEP 3 Click Apply. Your changes are saved to the Running Configuration.  
NOTE This page displays the following data for PoE power on the switch:  
Power: The current power status. If On, the switch is currently providing  
power through PoE to a connected device. If Off, the switch is not providing  
power through PoE to any connected devices.  
Maximum Available Power—The total power in watts that the switch is  
capable of making available to all PoE-capable ports.  
Threshold Power—The cutoff power value above which no additional PDs  
are powered. This threshold is calculated based on the Power Trap  
Threshold setting.  
Allocated Power—The total power in watts that the switch is actually  
providing to PoE ports.  
Cisco Small Business SG200 Series 8-port Smart Switch  
97  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Port Management  
Configuring PoE  
4
Configuring PoE Port Settings  
You can use the Port Settings page to view and configure settings for ports acting  
as PSEs.  
To configure PoE settings for a port:  
STEP 1 Click Port Management > PoE > Port Settings in the navigation window.  
The PoE Setting Table displays which ports are enabled for PoE operation, their  
priority, power allocation in milliwatts, and other settings for each port.  
STEP 2 Select the port to configure and click Edit.  
STEP 3 Configure the following settings:  
PoE—Check the Enable box to configure the port as a PSE.  
Power Priority Level—Select Critical, High, or Low to configure the port  
priority level, for the delivery of power to an attached device.  
The switch might not be able to supply power to all connected devices that  
request it. The port priority determines which ports supply power when  
adequate power capacity is not available for all enabled ports. For ports that  
have the same priority level, the lower-numbered port has higher priority. For  
a system delivering peak power to a certain number of devices, if a new  
device is attached on a high-priority port, power is shut down to a device on  
a low-priority port, and the new device is powered up.  
Power Limit Type— Select one of the following methods to limit the power  
that the switch provides to a connected device.  
-
Dot3AF—The maximum power that can be delivered by the port is  
limited by the detected IEEE 802.3af class.  
-
User-defined—The maximum power that can be delivered by the port  
is specified by the user. If you select this option, specify a value in the  
Power Allocation field.  
-
LLDP-MED—The maximum power that can be delivered by the port is  
limited by the value in LLDP-MED TLVs received from a port device. The  
value specified by the device should be in the range of 3-16.2 watts. If it  
is not in this range, then the default value of 16.2 watts is used.  
Note: If the selected Power Limit Type is LLDP-MED, then the priority  
setting from the remote device is not honored; instead the switch uses  
the Power Priority Level setting configured for the port.  
Cisco Small Business SG200 Series 8-port Smart Switch  
98  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Port Management  
Configuring PoE  
4
-
-
Dot3AF and LLDP-MED—The maximum power that can be delivered  
by the port is limited by the value in LLDP-MED TLVs received from a  
port device. The value specified by the device should be in the range of  
3-16.2 watts. If it is not in this range, then the maximum power is limited  
by the IEEE 802.3AF class.  
User-Defined and LLDP-MED—The maximum power that can be  
delivered by the port is limited by the value in LLDP-MED TLVs received  
from a port device. The value specified by the device should be in the  
range of 3-16.2 watts. If it is not in this range, then the maximum power is  
limited by the value that you specify in the Power Allocation field.  
Power Allocation—If you configured a user-defined option for Power Limit  
Type, enter the power in milliwatts to be allocated to the port, between 3000  
to 16200 milliwatts.  
Detection Type—Select one of the following methods to detect PoE-  
powered devices connected to the ports.  
-
-
802.3af 4point —Resistive signature devices detected with the first  
algorithm that correspond to the updated IEEE 802.3at-2009 PoE  
standard (also known as PoE+). It provides up to 51 W of power over a  
single cable by utilizing all four pairs in the Cat5 cable.  
802.3af 2point—Resistive signature devices detected with the first  
algorithm that correspond to the original IEEE 802.3af-2003 PoE standard  
that provides up to 15.4 W of DC power (minimum 44 V DC and 350 mA)  
to each device.  
Reset Mode—Select Enable to enable the switch initialize the ports PoE  
state machines.  
The following statistics also appear:  
Power Consumption—Actual power consumption on the port.  
Overload Counter—Total number of power overload occurrences.  
Short Counter—Total number of power short condition (electrical shorts) on  
a port.  
Denied Counter—Number of times the powered device was denied power.  
Absent Counter—Number of times the power supply was stopped to the  
powered device because the powered device was no longer detected.  
Cisco Small Business SG200 Series 8-port Smart Switch  
99  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Port Management  
Green Ethernet  
4
Invalid Signature Counter—Number of times an invalid signature was  
received. Signatures are the means by which the powered device identifies  
itself to the PSE. A signature is generated during powered device detection,  
classification, or maintenance.  
STEP 4 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
Green Ethernet  
The switch provides a Green Ethernet power saving feature on gigabit Ethernet  
copper ports called Energy Detect Mode. This feature helps reduce chip power  
by forcing a port PHY into a low-power mode when the signal from a copper link  
partner is not present. (PHY is an abbreviation for the physical layer of the OSI  
model.)  
When the Energy Detect is enabled, the switch automatically enters the low-  
power mode when energy on the line is lost, and it resumes normal operation  
when energy is detected. When the port PHY is in low-power mode, the PHY  
wakes up after a certain period of time, and sends link pulses to monitor for energy  
from the link partner. If energy is detected while the port is in wake-up mode, the  
switch returns the port to normal operation. When the wake-up period expires, the  
port returns to low-power mode.  
Energy Detect works whether the port has autonegotiation enabled or disabled,  
and can be enabled or disabled by the administrator. The Energy Detect Mode  
properties are configurable per-port.  
See the following topics for more information on the configuration pages available  
in the Port Management > Green Ethernet menu:  
Configuring Green Ethernet Properties  
You can use the Green Ethernet Properties page to enable Green Ethernet  
functionality globally. The global settings are applied to all ports.  
NOTE You can override the global settings by configuring these features on individual  
ports (see Configuring Green Ethernet Port Settings); however, changes you  
subsequently make to the global settings override any custom port configuration.  
Cisco Small Business SG200 Series 8-port Smart Switch  
100  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Port Management  
Green Ethernet  
4
To configure global Green Ethernet properties:  
STEP 1 Click Port Management > Green Ethernet > Properties in the navigation window.  
By default, Energy Detect mode is enabled globally and on all ports.  
STEP 2 If not already enabled, select Energy Detect Mode to enable this feature on the  
switch. The switch automatically enters the low-power mode when energy on the  
line is lost, and it resumes normal operation when energy is detected.  
STEP 3 Click Apply. Your changes are saved to the Running Configuration.  
Configuring Green Ethernet Port Settings  
Use the Green Ethernet Port Settings page to view and configure Energy Detect  
settings on individual ports.  
NOTE Energy Detect port settings are overridden if the global settings are subsequently  
To configure Green Ethernet port settings:  
STEP 1 Click Port Management > Green Ethernet > Port Settings in the navigation  
window.  
The Settings page displays the following Energy Detect fields for each port:  
Admin—Indicates whether Energy Detect is enabled on the port.  
Operational—Indicates whether Energy Detect mode is currently  
operational (“Enabled”) on the port.  
Reason—Indicates why the operational status is enabled or disabled.  
The following reason may display when the Energy Detect operational status  
is Enabled.  
- No Energy Detected—No energy is detected on the link.  
The following reasons might display when the Energy Detect operational  
status is Disabled.  
- Fiber—The administrative status might be active but the port is  
functioning in fiber mode. (Green Ethernet functionality applies only to  
copper ports.)  
Cisco Small Business SG200 Series 8-port Smart Switch  
101  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Port Management  
Green Ethernet  
4
- Link up—There is activity on the link.  
- Admin Down—Energy detect mode is administratively disabled.  
STEP 2 Select the port to configure and click Edit.  
STEP 3 Select Energy Detect to administratively enable Energy Detect on the port.  
STEP 4 Click Apply to save any changes to the Running Configuration.  
Cisco Small Business SG200 Series 8-port Smart Switch  
102  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
VLAN Management  
This chapter describes how to configure virtual LANs.  
It includes the following topics:  
Virtual LAN (VLAN) on a Layer 2 switch offers some of the benefits of both  
bridging and routing. Like a bridge, a VLAN switch forwards traffic based on the  
Layer 2 header, which is fast. Like a router, it partitions the network into logical  
segments, providing better administration, security, and management of multicast  
traffic.  
A VLAN is a set of end stations and the switch ports that connect them. You might  
have many reasons for the logical division, such as department or project  
membership. The only requirement is that the end station and the port to which it  
is connected both belong to the same VLAN(s).  
Each VLAN in a network has an associated VLAN ID, which appears in the IEEE  
802.1Q tag, also known as VLAN tag, in the Layer 2 header of packets transmitted  
on a VLAN. If an end station omits the tag, or the VLAN portion of the tag, the first  
switch port to receive the packet either rejects it or inserts a tag matching its  
default VLAN ID. A port can handle traffic for more than one VLAN, but it can only  
support the Port VLAN ID (PVID).  
The switch is pre-configured with VLAN ID 1 as the Default VLAN. All ports are  
members of this VLAN, and use its VLAN ID (1) as their PVID.  
Cisco Small Business SG200 Series 8-port Smart Switch  
103  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
VLAN Management  
Creating VLANs  
5
Creating VLANs  
The Create VLAN page enables you to define and configure VLANs on the  
network. To display this page VLAN Management > Create VLAN in the  
navigation window.  
The VLAN Table displays the VLAN ID, name, if one exists, and type for the pre-  
configured VLAN (VLAN ID 1) and any VLANs that you add. One port must be  
configured as the Default VLAN. The type for all other VLANs is Static. The switch  
is pre-configured with VLAN ID 1 as the Default VLAN. All ports are members of  
this VLAN, and use its VLAN ID (1) as their PVID.  
If you create additional VLANs, you can configure one of them as the Default VLAN.  
(See Setting the Default VLAN.) The configured Default VLAN cannot be deleted.  
A Static VLAN can be deleted. However, VLAN ID 1 cannot be deleted, even if it is  
configured as a Static VLAN.  
You can create up to VLANs, and assign VLAN IDs up to 4094. To create a new  
VLAN or a range of VLANs:  
STEP 1 Click Add.  
STEP 2 Select VLAN and enter a VLAN ID.  
Or, create a range of VLANs by selecting Range and specifying the beginning and  
ending VLAN IDs in the range.  
STEP 3 If you are creating a single VLAN, you can enter an optional VLAN name for easy  
reference.  
STEP 4 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
Configuring VLAN Interface Settings  
You can use the Interface Settings page to view and configure port VLAN tagging  
capabilities. To display this page click VLAN Management > Interface Settings in  
the navigation window.  
The Interface Setting Table shows the VLAN configuration for each port. To  
display the VLAN configuration on link aggregation groups, select LAG from the  
Interface Type list.  
Cisco Small Business SG200 Series 8-port Smart Switch  
104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
VLAN Management  
Configuring VLAN Interface Settings  
5
To configure VLAN interface settings:  
STEP 1 Select the port or LAG to configure and click Edit.  
STEP 2 Configure the following settings for the selected port or LAG:  
Interface VLAN Mode—Select an option to configure the port type with  
respect to VLAN membership and tagging.  
-
General—The port can be a member of one or more tagged or untagged  
VLANs. This mode allows the full capabilities specified in the IEEE 802.1Q  
specification, “VLAN Tagging.”  
-
Access—The port can accept only untagged frames. An access port can  
be a member of only one VLAN and it uses the VLAN ID as its port VLAN  
ID (PVID). Access ports are typically used to connect hosts, which  
become members of the VLAN by virtue of being physically connected  
to the port.  
-
Trunk—The port can be assigned to only one untagged VLAN, the native  
VLAN, and can be assigned to any number of tagged VLANs (or none).  
Trunk ports carry traffic for multiple VLANs from the switch to other  
network devices, such as an upstream router or an edge switch.  
PVID—(General ports only) The port VLAN ID indicates the default VLAN  
that the interface is a member of. Set the PVID equal to a VLAN ID where the  
port is an untagged member. (For Access ports, the PVID is automatically set  
to the Access VLAN ID. For Trunk ports, the PVID is set to the configured  
Native VLAN ID or, if None is configured, to the default VLAN ID.)  
Native VLAN—(Trunk ports only) The native VLAN identifies the one  
untagged VLAN membership for a trunk port. Select one of the following:  
-
-
-
None—The port has no untagged VLAN membership. The PVID for the  
port is set to the default VLAN ID.  
Default—The Native VLAN equals the default VLAN. The PVID for the  
port is also set to the default VLAN ID.  
User defined—The VLAN ID you specify is used as the untagged VLAN  
membership for the Trunk port. The PVID for the port is also set to the  
specified VLAN ID.  
Access VLAN—(Access ports only) An access port can be a member of  
only one VLAN, the Access VLAN. The port VLAN ID is set to the Access  
VLAN ID.  
Cisco Small Business SG200 Series 8-port Smart Switch  
105  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VLAN Management  
Configuring VLAN Interface Settings  
5
Frame Type—Specifies the frame type accepted on the port:  
Admit Untagged Only—Only untagged frames are accepted on the  
-
port. Tagged frames are discarded.  
-
Admit Tagged Only—Only tagged frames are accepted on the port.  
Untagged frames are discarded.  
-
Admit All—Both tagged and untagged frames are accepted on the port.  
An access port can admit untagged frames only. A trunk port can be  
assigned to only one untagged VLAN, called the native VLAN and, can be  
assigned to any number of tagged VLANs (or none). If a trunk port is member  
of both untagged and tagged VLANs, it admits all frame types. If the trunk  
port is member of tagged VLANs only, it admits tagged frames only.  
Ingress Filtering—Select to enable ingress filtering on the port. When  
ingress filtering is enabled, the switch accepts frames only from the VLANs  
of which it is a member. It discards frames received from other VLANs. All  
ports in access or trunk mode will always have their Ingress Filtering  
enabled. Disabling and enabling Ingress Filtering is only available on ports  
set to General Mode.  
VLAN Priority—The default 802.1p priority value for the port. The value will  
be applied to the incoming packets based on the QoS trust mode configured  
at the port and the types of the packets. See QoS Properties for information  
and instructions on configuring the port trust mode.  
STEP 3 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
Changing the Interface VLAN Mode  
When the interface VLAN mode of a port is changed, the switch automatically  
handles the affected VLAN membership configuration, as follows:  
Changing from Access Port to Trunk Port  
The VLAN configuration remains unchanged. The Access port VLAN becomes the  
native VLAN for the Trunk port. The port must follow the restrictions for Trunk  
ports.  
Cisco Small Business SG200 Series 8-port Smart Switch  
106  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
VLAN Management  
Configuring VLAN Interface Settings  
5
Changing from Trunk Port to Access Port  
If the original trunk port has an untagged VLAN member on the port, the port is  
removed from all its VLANs except the untagged VLAN on the port. The PVID is  
set to the untagged VLAN ID.  
If the original Trunk port does not have an untagged VLAN member on the port, the  
port is removed from all its VLANs and becomes a member of the default VLAN. Its  
PVID is set to the default VLAN ID and the port is set to admit only untagged or  
priority-tagged packets. The port is untagged for the default VLAN.  
Changing from Access Port to General Port  
The VLAN configuration remains unchanged except that the port can now admit all  
frames. As a General port, it can be a tagged or an untagged member of any  
VLAN.  
Changing from General Port to Access Port  
If the General port has no untagged VLAN membership that provides the PVID for  
the port, when the port is changed to an Access port it is removed from all the  
General port's VLANs and becomes an untagged member of the default VLAN.  
The Access port PVID is set to the default VLAN.  
The Access port admits only untagged or priority-tagged packets.  
Changing from Trunk Port to General Port  
The VLAN configuration remains unchanged. As a General port, the port can be a  
tagged or an untagged member of any VLAN.  
Changing from General Port to Trunk Port  
The VLAN configuration remains unchanged. The PVID of the General port is used  
to configure the native VLAN of the Trunk port. The port must follow the  
restrictions of the Trunk port.  
For example, assume a General port is an untagged member of VLANs 1, 10, and  
20, and the port’s PVID is 1.  
When the port is changed to a Trunk port, VLAN 1 becomes the native VLAN. The  
Trunk port remains a member of VLANs 10 and 20, but now with tagging enabled.  
Deleting a VLAN  
When a VLAN is deleted, the following actions occur:  
If the deleted VLAN was a Trunk port’s native VLAN, the trunk port’s native  
VLAN and PVID are changed to the default VLAN.  
Cisco Small Business SG200 Series 8-port Smart Switch  
107  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VLAN Management  
Configuring VLAN Membership  
5
If an Access port was a member of the deleted VLAN, the Access port  
becomes a member of the default VLAN and its PVID is changed to the  
default VLAN.  
If a General port was configured to use the VLAN ID as its PVID, the General  
port’s PVID is changed to the default VLAN ID. No other VLAN memberships  
are changed.  
Configuring VLAN Membership  
You can use these pages to view and configure VLAN memberships:  
The Port to VLAN page enables you to select a VLAN and configure its  
member ports. See Configuring Port to VLAN.  
The Port VLAN Membership page enables you to select a port and  
configure it as a member of one or more VLANs. See Configuring Port  
By default, all ports are members of VLAN 1. You can change the VLAN  
membership of any port. VLAN memberships can be configured as tagged or  
untagged.  
If the switch receives an untagged frame from a VLAN, the switch will insert  
a VLAN tag before forwarding the frame to the egress ports that are  
configured as tagged members of the VLAN.  
If the switch receives an untagged frame from a VLAN, the switch will  
forward the frame as is to egress ports that are configured as untagged  
members of the VLAN.  
If the switch receives a tagged frame from a VLAN, the switch will remove  
the VLAN tag before forwarding the frame to the egress ports that are  
configured as untagged members of the VLAN.  
If the switch receives a tagged frame from a VLAN, the switch will forward  
the frame as is to egress ports that are configured as tagged members of  
the VLAN.  
Cisco Small Business SG200 Series 8-port Smart Switch  
108  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
VLAN Management  
Configuring VLAN Membership  
5
Configuring Port to VLAN  
Use the Port to VLAN page to:  
Configure ports as members of a selected VLAN.  
Specify that when a port receives packets from the selected VLAN, the  
packets are tagged with the VLAN ID upon forwarding.  
Specify that the selected VLAN ID serves as the port VLAN ID (i.e., the  
selected VLAN ID is added when the port forwards packets that it receives  
with no VLAN membership).  
To configure port VLAN memberships:  
STEP 1 Click VLAN Management > Port To VLAN in the navigation window.  
The configured interface port mode (access, trunk, or general) of each port affects  
how the port can be assigned to VLANs. See Configuring VLAN Interface  
Settings for instructions on configuring the port mode setting.  
STEP 2 Select the VLAN ID to configure and use the Interface Type list to display either  
ports or LAGs.  
STEP 3 For each interface, configure the following parameters:  
Member—Check this box if a port is to be member of the VLAN. Uncheck  
this box if a port is not to be member of the VLAN. A port is not member of  
the VLAN by default.  
Tagged—Select Tagged if all the packets of the VLAN egress to the port are  
to be tagged. Otherwise, select Untagged. A trunk port is tagged by default.  
This option is only relevant if the port is a member of the VLAN.  
Untagged—Select Untagged if the packets from the VLAN egress to the  
port are to be untagged. Otherwise, select Tagged. An access port is always  
untagged. A general port is untagged by default. This option is relevant only  
if the port is a member of the VLAN.  
PVID—Check this box if a port is to use the selected VLAN ID as its port  
VLAN ID (PVID). Otherwise, uncheck this box. If PVID is selected for an  
access or trunk port, the port must be an untagged member of the VLAN.  
Untagged packets received from the port will be assigned to the  
corresponding VLAN.  
STEP 4 Click Apply. Your changes are saved to the Running Configuration.  
Cisco Small Business SG200 Series 8-port Smart Switch  
109  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
VLAN Management  
Configuring VLAN Membership  
5
Configuring Port VLAN Membership  
To configure VLAN settings for ports:  
STEP 1 Click VLAN Management > Port VLAN Membership in the navigation window.  
By default, the page displays VLAN information for each port. You can use the filter  
settings to display the VLAN information for LAG ports. The page displays the  
interface VLAN mode (Trunk, Access, or General), the PVID, and the VLAN  
membership(s). If a port is a member of multiple VLANs, you can select the port  
and click Detail to display this information for a single port.  
STEP 2 Select a port or LAG to configure and click Edit.  
STEP 3 To assign or remove a VLAN membership, use the arrow buttons as described  
below.  
To add a VLAN membership: Click a VLAN in the Available list, change its  
Tagging properties if needed (see below), and then click the right-arrow  
button to move it to the Selected list.  
To remove a VLAN membership: Click a VLAN in the Selected list, and then  
click the left-arrow button to move it to the Available list.  
Tagging and PVID Properties  
Depending on the interface VLAN mode (Trunk, Access, or General), when you  
select a VLAN in the Available list, you can specify the following properties for the  
interface before moving the VLAN to the Selected list for the interface.  
Membership—The interface can be configured as a tagged or untagged  
member of the selected VLAN.  
-
Tagged—If selected, the port is a tagged member of the selected VLAN.  
When the switch forwards packets it receives for this VLAN through this  
interface, it adds the VLAN ID to the packet.  
-
Untagged—If selected, the port will be an untagged member of the  
selected VLAN. When the switch forwards packets for this VLAN through  
this interface, it does not add the VLAN ID to the packet.  
If the interface VLAN mode is General, you can select either option for any  
VLAN. If the interface VLAN mode is Access, only one VLAN can be selected  
and the Untagged option must be selected for the interface. If the interface  
VLAN mode is Trunk, the interface can be specified as an Untagged member  
of one VLAN and can be specified as a Tagged member of other VLANs.  
Cisco Small Business SG200 Series 8-port Smart Switch  
110  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
VLAN Management  
Setting the Default VLAN  
5
PVID—When this option in selected, the port uses the selected VLAN ID as  
its port VLAN ID (PVID). The port assigns the PVID to all untagged frames  
received on the port before forwarding. The following configuration rules  
apply:  
-
-
-
If the interface VLAN mode is General, any VLAN of which the interface is  
a Tagged or Untagged member can be selected to provide the PVID.  
If the interface VLAN mode is Trunk, the PVID is set to the VLAN ID of  
which the port is a tagged member.  
If the interface VLAN type is Access, the PVID is set to the Access VLAN  
ID and this field cannot be modified.  
When you select the Untagged, Tagged, and PVID options and move the VLAN to  
the Selected list, a U, T, and/or P is appended to the VID.  
STEP 4 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
Setting the Default VLAN  
By default, the switch automatically creates VLAN 1 as the default VLAN for all  
ports and link aggregation groups (LAGs). If a port has no VLAN memberships, the  
switch automatically configures it as a member of the default VLAN.  
You can use the Default VLAN Settings page to change the default VLAN.  
When the VID of the default VLAN is changed:  
Ports that were members of the original default VLAN are removed as  
members of that VLAN and are configured as members of the new default  
VLAN.  
The Port VLAN Identifier (PVID) of the ports that were members of the  
original default VLAN is changed to the VID of the new default VLAN.  
If the management VLAN was the same as the original default VLAN, then  
the management VLAN is updated to the new default VLAN provided there  
is at least one member port. If DHCP is enabled, the switch attempts to  
renew the switch IP address through DHCP.  
Cisco Small Business SG200 Series 8-port Smart Switch  
111  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
VLAN Management  
Voice and Media  
5
The type of the original default VLAN is changed from Default to Static, and  
it can be deleted. One exception is VLAN 1. Even if it is no longer designated  
as the default VLAN, VLAN 1 cannot be deleted.  
To s e l e c t a d e f a u l t V L A N :  
STEP 1 Click VLAN Management > Default VLAN Settings in the navigation window.  
STEP 2 Select the VLAN from the list.  
STEP 3 Click Apply.  
Voice and Media  
Voice-over-Internet-Protocol (VoIP) allows using a computer data network for  
voice telephone calls. With the increased deployment of delay-sensitive  
applications such as VoIP in modern networks, proper QoS configuration is  
needed to ensure high-quality performance. The Voice and Media feature  
provides a simple classification mechanism for voice packets so that they can be  
prioritized above data packets.  
The Voice and Media feature identifies VoIP streams in Ethernet switches and  
provides them with a better Class-of-Service (CoS) than ordinary traffic. The  
switch supports two types of Voice and Media:  
Protocol-based—Identifies a VoIP session using the Session Initiation  
Protocol (SIP) and H.323 control traffic, and assigns these packets the  
highest priority on the voice VLAN.  
OUI-based—Ports that are enabled for this feature automatically become  
members of the configured voice VLAN. The switch detects  
Organizationally Unique Identifier (OUI) values in the first three bytes of the  
MAC addresses in client packets to classify them on the VoIP VLAN and  
prioritize them on the Auto VoIP-enabled ports.  
These topics for more information on the configuration pages available in VLAN  
Management > Voice and Media:  
Cisco Small Business SG200 Series 8-port Smart Switch  
112  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
VLAN Management  
Voice and Media  
5
Displaying and Adding Telephony OUI  
The Telephony OUI page lists the Organizationally Unique Identifiers (OUIs)  
associated with different voice VLANs.  
To display this page, click VLAN Management > Voice and Media > Telephony  
OUI in the navigation window.  
The Telephony OUI Table is preconfigured with identifiers for commonly used  
telephony devices. The administrator can add or remove OUIs. When Voice and  
Media is enabled, ports use the OUI digits in the source and/or destination MAC  
addresses of incoming packets to automatically assign voice traffic to a voice  
VLAN. See Configuring OUI Based Voice and Media for instructions on  
associating the VLAN with an IEEE 802.1p priority and enabling ports for Voice and  
Media.  
To add a new OUI description:  
STEP 1 Click Add.  
STEP 2 Specify the following values:  
Telephony OUI—Enter a 3-octet identifier for the telephony application.  
Description—Enter a description of the service such as the vendor name or  
telephony product.  
STEP 3 Click Apply and Close.  
Configuring OUI Based Voice and Media  
You can use the Telephony OUI Based Auto VoIP page to:  
Configure an IEEE 802.1p priority level for Voice and Media traffic identified  
using the OUI digits in MAC addresses.  
Specify the VLAN for OUI-based VoIP packets. Although you can assign a  
VLAN ID that has not yet been created on the switch, you must  
subsequently create the VLAN for the feature to be operational (see  
Cisco Small Business SG200 Series 8-port Smart Switch  
113  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
VLAN Management  
Voice and Media  
5
Enable ports for this feature. When enabled on a port, the port is  
automatically made member of the configured voice VLAN when the switch  
receives an OUI frame (the administrator does not need to manually add the  
port as a member of the VLAN).  
The Port VLAN Membership page shows that the port is a member of the Voice  
VLAN.  
To configure OUI-based Voice and Media:  
STEP 1 Click VLAN Management > Voice and Media > Telephony OUI Based in the  
navigation window.  
STEP 2 Check VLAN to enable modifying the VLAN ID and Priority fields.  
STEP 3 In the VLAN ID field, specify the VLAN to carry voice traffic. This VLAN should  
already be configured on the switch (see Creating VLANs).  
STEP 4 In the Priority field, specify the IEEE 802.1p Class-of-Service (CoS) priority level for  
VoIP traffic.  
STEP 5 Click Apply. Your changes are saved to the Running Configuration.  
STEP 6 In the Telephony OUI Based Interface Settings Table, select an interface to  
configure, and then click Edit.  
NOTE: Set the an auto VoIP port to be a General port, not a Trunk or Access port.  
STEP 7 Select Enable for the Auto VoIP mode. The port is automatically added as a  
member of the voice VLAN.  
STEP 8 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
Configuring SIP/H323 Based Voice and Media  
You can use the SIP/H323 Based Auto VoIP page to configure the switch to  
recognize VoIP traffic by its protocol, such as the Session Initiation Protocol (SIP)  
and H.323. The traffic is automatically assigned the highest priority available on  
the system.  
To configure SIP/H323 based Voice and Media:  
Cisco Small Business SG200 Series 8-port Smart Switch  
114  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
VLAN Management  
Voice and Media  
5
STEP 1 Click VLAN Management > Voice and Media > SIP/H323 Based in the navigation  
window.  
The table lists the administrative and operational statuses for SIP/H323 Auto VoIP  
on each interface, and shows the class that traffic will be assigned to. The traffic  
class corresponding to the highest priority queue on the port is chosen  
automatically.  
STEP 2 Use the Interface Type menu to display ports or LAGs in the SIP/H323 Based  
Interface Settings Table.  
STEP 3 Select the port or LAG interface to configure and click Edit.  
STEP 4 Select Enable for the Auto VoIP Mode.  
STEP 5 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
Media VLAN  
The Media VLAN feature enables switch ports to carry voice, video, and signaling  
traffic with an assigned priority value. Assigning different priorities to traffic  
enables separation of media and data traffic coming into a port. The Media VLAN  
feature helps to ensure that the sound or video quality of an IP phone or video  
device is safeguarded from deterioration when data traffic on the port is high.  
The inherent traffic isolation provided by VLANs ensures that inter-VLAN traffic is  
under management control and that network-attached clients cannot initiate a  
direct attack on voice components. The switch uses the IP-DSCP or 802.1p value  
in packets from media devices to assign this traffic to high priority queues.  
The switch uses Media VLANs to support LLDP-MED applications. (See LLDP-  
MED for information on the protocol.) Each Media VLAN corresponds to an LLDP-  
MED application for a specific type of media traffic. The LLDP-MED applications  
are voice, voice signaling, guest voice, guest voice signaling, softphone voice,  
video conferencing, streaming video, and video signaling. Each Media VLAN is  
associated with the following parameters  
A VLAN with optional VLAN tagging  
An IEEE 802.1p priority value  
A DSCP value  
Cisco Small Business SG200 Series 8-port Smart Switch  
115  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
VLAN Management  
Voice and Media  
5
When a port is LLDP-MED enabled with network policy, the switch will advertise  
its Media VLANs in the LLDP-MED network policy TLVs out to the port. When a  
LLDP Media Endpoint is discovered, the switch will install the Media VLAN at the  
corresponding port. You can enable LLDP-MED and networking policy in the  
Administration > Discovery - LLDP pages.  
Media VLAN is enabled and disabled globally. Each application and its Media  
VLAN is configured on a per-port basis. For example, Guest Voice can be on  
Media VLAN 1 on interface g1, but can be on Media VLAN 10 on interface g2.  
The Media VLAN Interface Settings Table displays each media traffic type that  
can be enabled, and shows its status and settings on the selected port.  
To configure Media VLAN applications:  
STEP 1 Click VLAN management > Voice and Media > Media VLAN in the navigation  
window.  
STEP 2 Select Enable for Admin Mode to globally enable this feature on the switch, and  
then click Apply.  
STEP 3 Select an interface to configure from the Interface list.  
!
CAUTION Ports that are members of a LAG cannot be enabled for Media VLAN applications  
STEP 4 From the Application list, select the media traffic type to configure:  
Voice  
Voice Signaling  
Guest Voice  
Guest Voice Signaling  
Softphone Voice  
Video Conferencing  
Streaming Video  
Video Signaling  
STEP 5 Click Edit.  
Cisco Small Business SG200 Series 8-port Smart Switch  
116  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VLAN Management  
Voice and Media  
5
STEP 6 For Application Status, select Enable to enable priority assignment for the  
selected application. Uncheck the box to disable this feature.  
STEP 7 If you enabled Application Status, enable or disable the following features:  
Untagged—Select Enable if the media device (LLDP-MED Endpoint) will  
send untagged packets. The network policy TLV from the switch must also  
indicate this expectation, and a media device must acknowledge that it will  
use untagged frames. Uncheck the box to disable this feature.  
VLAN and VLAN ID—Select Enable to specify a VLAN, and then choose a  
VLAN ID from the list. Uncheck the box to disable this feature.  
Priority and Priority Value—Select Enable to prioritize packets of the  
selected application. Then enter an IEEE 802.1p class-of-service priority  
tagging value for Media VLAN traffic. The priority tag range is 0–7.  
DSCP and DSCP Value—Select Enable to specify a DSCP for the selected  
application. Then enter a DSCP value for the port. The range is 0-63.  
STEP 8 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
STEP 9 Ensure that LLDP-MED is enabled on the interface. You can click Enable LLDP-MED  
Network Policy to display the LLDP-MED Port Settings page. See LLDP-MED for  
more information.  
Auto VoIP Sessions  
The Auto VoIP Sessions page displays information about the source, destination,  
and protocol for each Voice over IP session.  
Cisco Small Business SG200 Series 8-port Smart Switch  
117  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6
Spanning Tree  
This chapter describes how to configure the Spanning Tree Protocol (STP) on the  
switch.  
It includes the following topics:  
Overview of Spanning Tree  
STP enables efficient communication on a network that includes multiple bridges.  
Devices on these networks can learn multiple (that is, redundant) paths to the  
same endpoint. While path redundancy is desirable for maintaining traffic flow  
when particular links are down, it can lead to a traffic loops that affect network  
performance and confuse forwarding algorithms.  
Each STP-enabled bridge exchanges Bridge Protocol Data Units (BPDUs) with  
other bridges. BPDUs identify the bridge port MAC addresses and the priority and  
cost associated with each port. STP uses this information to build a topology that  
provides one active path between any two stations on the network. Duplicate  
paths between those stations are placed in a stand-by state for use only when the  
active path becomes unavailable.  
BPDU exchanges also facilitate the election of a root bridge and root port for the  
network. The root bridge provides a reference point that each other bridge uses to  
calculate a lowest-cost path by summing the cost of the ports in each path and  
choosing the one with the lowest total. The port that connects a bridge to the  
lowest-cost path is called the bridge’s root port.  
Cisco Small Business SG200 Series 8-port Smart Switch  
118  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Spanning Tree  
Configuring STP Status and Global Settings  
6
When the root bridge is selected and each root port is established, each network  
segment can then determine which bridge provides the lowest cost path to the  
root port. The port that provides this path is named the designated port for the  
network segment. Spanning tree disables other ports for that network segment or  
designates them as alternate or backup ports.  
Supported spanning tree versions include Common Spanning Tree (CST) and  
Rapid STP (RSTP). This switch does not support Multiple STP (MSTP).  
CST (IEEE 802.1D) is the original protocol version that provides a single path  
between end stations, avoiding and eliminating loops.  
RSTP (IEEE 802.1D-2004 or IEEE 802.1w) provides protocol enhancements  
that enable a network to more quickly achieve an optimal STP topology.  
Spanning tree is enabled by default and set to be RSTP.  
Configuring STP Status and Global Settings  
You can use the STP Status & Global Settings page to enable STP, select the STP  
mode of operation, and configure bridge priority settings. You can also view status  
information about the STP topology. To display this page, click Spanning Tree >  
STP Status & Global Settings in the navigation window.  
This page enables you to configure global settings and bridge settings, and  
displays information about the designated root.  
Configuring Global and Bridge Settings  
To configure STP global settings and bridge settings:  
STEP 1 Specify the following global settings:  
Spanning Tree State—Select to enable STP operation on the switch. You  
must also enable STP operation on individual ports (see Configuring STP  
Cisco Small Business SG200 Series 8-port Smart Switch  
119  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Spanning Tree  
Configuring STP Status and Global Settings  
6
STP Operation Mode—Select one of the following STP modes:  
-
Classic STP—Operates according to the original IEEE 802.1D spanning  
tree protocol.  
-
Rapid STP—Is the default value and provides faster spanning tree  
convergence after a topology change than does classic STP.  
BPDU Handling—Bridge Protocol Data Units (BPDUs) are the messages  
exchanged between switches to calculate STP topology. Select the method  
of BPDU packet handling when the spanning tree is disabled on an interface:  
-
Filtering—Enables the port to discard BPDUs received on interfaces that  
are not enabled for STP.  
-
Flooding—Allows flooding of BPDUs received on non-spanning-tree  
ports to all other non-spanning-tree ports.  
STEP 2 Specify the following bridge setting:  
Priority—The bridge priority value. When switches or bridges are running  
STP, each is assigned a priority. After exchanging BPDUs, the switch with the  
lowest bridge identifier becomes the root bridge. The bridge priority must  
be a multiple of 4096. If you specify a priority that is not a multiple of 4096,  
the priority is automatically set to the next lowest multiple of 4096. For  
example if you attempt to set the priority to any value between 0 and 4095,  
it will be set to 0. The default priority is 32768. The valid range is 0-61440.  
CST Bridge Max Age—The amount of time in seconds that a bridge waits  
before implementing a topological change. The valid range is 6-40 seconds.  
The default is 20 seconds.  
CST Bridge Forward Delay—The amount of time in seconds that a bridge  
remains in a listening and learning state before forwarding packets. The valid  
range is 4-30 seconds. The default is 15 seconds.  
The following information appears in this section of the page:  
Hello Time—The interval at which a bridge sends configuration messages.  
Max Hops—The number of hops before a BDPU is discarded and the port  
information is aged out. The maximum hop count is set to 20 and is not  
configurable.  
Hold Time—The minimum time period, in seconds, that elapses between  
the transmission of Configuration BPDUs through a bridge port.  
Cisco Small Business SG200 Series 8-port Smart Switch  
120  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Spanning Tree  
Configuring STP Interface Settings  
6
The following information appears in the Designated Root section of the page:  
Bridge ID—The bridge identifier, which is a concatenation of the bridge  
priority and the base MAC address of the bridge.  
Root Bridge ID—The Bridge ID of the root bridge. The bridge with the lowest  
Bridge ID among all the bridges become the root bridge.  
Root Port—The port number that offers the lowest-cost path from this  
bridge to the root bridge. It is significant when the bridge is not the root. The  
default is zero.  
Root Path Cost—The cost of the path from this bridge to the root.  
Topology Changes Count—The total amount of STP state changes that  
have occurred.  
Last Topology Change—The total amount of time since the last topographic  
change.  
STEP 3 Click Apply. Your changes are saved to the Running Configuration.  
Configuring STP Interface Settings  
The STP Interface Settings page assigns STP properties to individual ports or  
LAGs. These settings are applicable to both the Classic STP and Rapid STP.  
To edit settings for a port or LAG:  
STEP 1 Click Spanning Tree > STP Interface Settings in the navigation window.  
The STP Interface Settings Table displays configuration information for each port  
and LAG. By default, all ports are enabled for STP operation.  
NOTE: The list ports/LAGs might span more than one page. Use the Page list to  
display the next set of entries.  
STEP 2 Select the port or LAG to configure and click Edit.  
STEP 3 Enter the parameters:  
Cisco Small Business SG200 Series 8-port Smart Switch  
121  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Spanning Tree  
Configuring STP Interface Settings  
6
STP—Select to enable STP operation on the port/LAG.  
Auto Edge—Select Enable to allow the switch to automatically determine if  
the port is an edge port or PortFast. A port is an edge port if it is not  
connected to a bridge. Auto-detection speeds up the transition of the port to  
forwarding state. A port can forward traffic and learn MAC addresses when  
it is in forwarding state.  
Edge Port—Select Enable to manually configure the port as an edge port.  
BPDU Handling—Bridge Protocol Data Units (BPDUs) are the messages  
exchanged between switches to calculate STP topology. Select the method  
of BPDU packet handling when the spanning tree is disabled on an interface:  
-
Filtering—Enables the port to discard BPDUs received on interfaces  
that are not enabled for STP.  
-
Flooding—Allows flooding of BPDUs received on non-spanning-tree  
ports to all other non-spanning-tree ports.  
Path Cost—Specify the port path cost. The cost of a path to the root bridge  
is the sum of the costs of all ports in the path. The path cost is used by CST  
and RSTP to forward traffic when a path is being rerouted. Select Use  
Default to set the path cost to the port speed. Or select User Defined to set  
a custom value between 0 and 200,000,000. A value of zero means the path  
cost is set according to the port's speed.  
STEP 4 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
The new configuration appears in the STP Interface Settings Table along with the  
following information about the port/LAG.  
Operational Edge Status—Indicates if a port is currently operating as an  
edge port (or PortFast port). This will indicate Enabled if the port is in the  
forwarding state due to either of the following configurations:  
-
The port is configured as an Edge Port and is therefore automatically in  
the forwarding state.  
-
The port is configured as an Auto Edge port and, because it has not  
received BDPUs, has transitioned to forwarding state.  
Cisco Small Business SG200 Series 8-port Smart Switch  
122  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Spanning Tree  
RSTP Interface Settings  
6
Port State—Current STP state of a port. If enabled, the port state  
determines the forwarding action that is taken on traffic. Possible port states  
are:  
-
Disabled—STP is currently disabled on the port. The port does not  
participate in the spanning tree, but is in an operational state to learn  
MAC addresses and forward traffic.  
-
-
-
Discarding—Port is currently blocked and cannot be used to forward  
traffic or learn MAC addresses.  
Learning—Port is currently in the learning mode. The port cannot  
forward traffic, however, it can learn new MAC addresses.  
Forwarding—Port is currently in the forwarding mode. The port can  
forward traffic and learn new MAC addresses.  
Designated Bridge ID—Bridge identifier of the bridge that offers the  
lowest root path cost to a LAN. The ID is a concatenation of the bridge  
priority and the base MAC address of the bridge.  
Designated Port ID—Port identifier on the Designated Bridge that offers  
the lowest root path cost to the LAN. The ID is a concatenation of the port  
priority and the interface number of the port.  
Designated Cost—The root path cost from the designated bridge to the  
root bridge. Ports with lower designated cost are less likely to be blocked  
when STP detects loops.  
Speed—Port speed.  
LAG—LAG that the port is a member of, if any.  
RSTP Interface Settings  
Rapid Spanning Tree Protocol (RSTP) ensures a faster convergence of a loop-free  
spanning tree for any bridged LAN. To display the RSTP Interface Settings page,  
click Spanning Tree > RSTP Interface Settings in the navigation window.  
A rapid spanning tree topology is formed automatically when RSTP is selected as  
the spanning tree mode. Use the STP Status & Global Settings page to enable  
RSTP mode.  
Cisco Small Business SG200 Series 8-port Smart Switch  
123  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Spanning Tree  
RSTP Interface Settings  
6
By default, the RSTP Interface Settings Table displays information for each port.  
Use the Interface Type list to display ports or LAGs in the table. The RSTP  
Interface Table displays the following information for each port:  
Point to Point Operational Status—A physical port has a point-to-point  
connection to a LAN if it operates in full duplex.  
Port Role—Port role assigned by the STP algorithm to provide to STP paths.  
The possible field values are:  
-
-
-
-
Root—Provides the lowest root path cost to the root bridge among all  
the ports in the switch.  
Designated—Provides the lowest root path cost to the root bridge from  
a LAN. The switch is the designated bridge in the LAN.  
Alternate—Provides an alternate path to the root bridge from the root  
interface.  
Backup—Provides a backup path to the designated port path toward  
the Spanning Tree leaves. Backup ports occur only when two ports are  
connected in a loop by a point-to-point link, or when a LAN has two or  
more connections connected to a shared segment.  
-
Disabled—The port is not participating in the Spanning Tree.  
Mode—Indicates whether the RSTP administrative mode is enabled or  
disabled for the port.  
Edge Port Operational Status—If enabled for the port or LAG, the port is  
automatically placed in the forwarding state. See Configuring STP  
Interface Settings for instructions on modifying this setting.  
Port Status—The operational state of the port.  
You can select a port and click Activate Protocol Migration to have the switch  
send RSTP BPDUs to the port. This can be used to test whether all legacy bridges  
on the LAN have been removed.  
Cisco Small Business SG200 Series 8-port Smart Switch  
124  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Spanning Tree  
RSTP Interface Settings  
6
MSTP Instance Settings  
MSTP Interface Settings  
Cisco Small Business SG200 Series 8-port Smart Switch  
125  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Spanning Tree  
RSTP Interface Settings  
6
Cisco Small Business SG200 Series 8-port Smart Switch  
126  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
MAC Address Tables  
This chapter describes the static configuration and dynamic learning of Media  
Access Control (MAC) addresses into the filtering database of the switch. The  
switch searches its filtering database to determine which port a packet is to be  
forwarded to. The filtering database is also referred as the bridging table in this  
document. The search is based on the VLAN and destination MAC address of the  
packet. If search does not result with a matching entry, the switch floods the  
packets to the VLAN excluding the ingress port.  
It includes the following topics:  
Configuring Static MAC Addresses  
The Static Addresses page displays a list of MAC addresses that are manually  
configured into the bridging table of the switch. A static MAC address is also  
associated with a VLAN and a port.  
To add static MAC address entries:  
STEP 1 Click MAC Address Tables > Static Addresses in the navigation window.  
STEP 2 Click Add.  
STEP 3 Enter the parameters:  
VLAN ID—Select the VLAN in which the device with the static MAC address  
resides.  
Interface—Specify the port/LAG in which the device with the static MAC  
addresses can be reached.  
Cisco Small Business SG200 Series 8-port Smart Switch  
127  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
MAC Address Tables  
Configuring Static MAC Addresses  
7
MAC Address— Enter the static MAC address.  
Status—Select a status for this static MAC address:  
-
Permanent—When this status is selected, the static MAC address does  
not expire. Note, however, that if the switch is rebooted, the entry is not  
restored unless the Running Configuration file type was copied to the  
Startup Configuration file type. See Copying and Saving Configuration  
Files.  
-
-
Delete on Timeout—When this status is selected, the static MAC  
address is static but may expire due to inactivity. In this respect, it is  
treated like a dynamically learned MAC address. See the Dynamic  
Address Settings to set the aging period.  
Secure—When this status is selected, the MAC address is secured and  
is used in conjunction with the Port Security feature. When a MAC  
address is secured at a port, packets that originate from the MAC  
address can only be ingressed from the secured port. Otherwise, the  
packets are discarded. If port security is disabled on the port, the MAC  
address is deleted from the static MAC address list. When Port Security  
is enabled at a port, the port can support a maximum of 256 static and  
dynamic MAC addresses. (For more information, see Enabling Port  
STEP 4 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
NOTE To delete a static MAC address, select it in the table and click Delete.  
Cisco Small Business SG200 Series 8-port Smart Switch  
128  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAC Address Tables  
Configuring the Aging Time for Dynamic Addresses  
7
Configuring the Aging Time for Dynamic Addresses  
The Dynamic Address Settings page enables you to set an aging time, after  
which the system removes addresses in the dynamic MAC address table that  
have not been refreshed. The aging period applies to dynamically learned  
addresses and to static addresses that are configured to Delete on Timeout. The  
default aging time is 300 seconds.  
To configure the aging time:  
STEP 1 Click MAC Address Tables > Dynamic Address Settings in the navigation  
window.  
STEP 2 Specify an aging time from 10 to 1,000,000 seconds.  
STEP 3 Click Apply. Your changes are saved to the Running Configuration.  
Dynamic MAC Addresses  
When the switch cannot find an entry in its bridging table that matches the VLAN  
and the destination MAC address of an incoming packet, the switch learns the  
MAC address, the VLAN, and the ingress port of the packet and adds an entry to  
the Dynamic Address table.  
To prevent the bridging table from overflowing and to make room for new  
addresses, an address is deleted from the bridging table if no traffic is received  
from a dynamic MAC address for the configured aging period (see Configuring  
To display the Dynamic Addresses page, click MAC Address Tables >  
Dynamic Addresses in the navigation window.  
NOTE This page might take up to 45 seconds to display when the Dynamic Address Table  
contains the maximum number of entries.  
By default, the Dynamic Address Table displays all dynamically learned MAC  
addresses. You can enter filter criteria and click Go to filter the display. Use the  
VLAN ID filter to display table entries for a particular VLAN. Use the MAC Address  
filter to display entries for a particular MAC address. Use the Interface filter to  
display entries for a particular port or LAG. Click Clear Filter to display all of the  
entries.  
Cisco Small Business SG200 Series 8-port Smart Switch  
129  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
MAC Address Tables  
Dynamic MAC Addresses  
7
The Dynamic Address Table displays the following fields for each entry it learns:  
VLAN ID—VLAN on which the MAC address was learned. Frames are  
forwarded to the interface only if they are associated with this VLAN.  
MAC Address—The dynamically learned MAC address.  
Interface—The port on which the MAC address was dynamically learned.  
Frames specifying this MAC address and VLAN as the destination are  
forwarded out to this port.  
Click Clear Table to clear all dynamic MAC address entries from the table.  
Cisco Small Business SG200 Series 8-port Smart Switch  
130  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
Multicast  
This chapter describes how to configure the multicast protocols that forward  
packets from one source to multiple destinations.  
It contains the following topics:  
Multicast protocols deliver packets from one source to multiple receivers. They  
facilitate better bandwidth utilization and help to reduce the processing load on  
hosts and routers, making them ideal for use in applications such as video and  
audio conferencing, whiteboard tools, and stock distribution tickers.  
The switch maintains a multicast forwarding table to make forwarding decisions  
for packets that arrive with a multicast destination MAC address. When multicasts  
are restricted only to specified ports, traffic is prevented from going to parts of the  
network where there are no receivers. When a packet enters the switch, the  
destination MAC address is combined with the VLAN ID and a search is performed  
in the multicast forwarding table. If no match is found, then the packet is either  
flooded to all ports in the VLAN or discarded, depending on the switch  
configuration. If a match is found, the packet is forwarded only to the ports that are  
members of that multicast group.  
Cisco Small Business SG200 Series 8-port Smart Switch  
131  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Multicast  
Multicast Properties  
8
Multicast entries can be learned by snooping (listening in on) the layer 3 protocols  
that manage multicast memberships:  
IPv4 multicast group addresses can be learned through the Internet Group  
Management protocol (IGMP).  
IPv6 multicast group addresses can be learned through the Multicast  
Listener Discovery (MLD) protocol.  
Interfaces with IGMP and MLD multicast routers for a specific VLAN can be either  
statically or dynamic configured. The multicast routers use IGMP and MLD to  
manage the membership of the multicast groups. A multicast router is also  
required in order for the switch to support IGMP/MLD snooping properly in a  
VLAN.  
Multicast Properties  
You can use the Multicast Properties page to specify how multicast packets are  
forwarded within VLANs.  
When you create a VLAN, a default multicast forwarding option is assigned. You  
can use the Global Multicast Mode setting to set all VLANs currently configured on  
the switch to a selected forwarding mode. The global setting does not create a  
default setting for VLANs created subsequently—it simply ensures that all existing  
VLANs are configured with the specified mode. You can also configure how the  
switch forwards multicast packets on an individual or per-VLAN basis.  
Configuring a Multicast Forwarding Mode on all VLANs  
To configure all current VLANs with a particular multicast forwarding mode:  
STEP 1 Click Multicast > Properties in the navigation window.  
STEP 2 Select a Global Multicast Mode to apply to all VLANs. If a VLAN has been  
configured with a different mode, it is reset to the following mode:  
Forward Unregistered—If a packet is received from a VLAN with a  
multicast destination address and no ports in the VLAN are registered to  
receive multicast packets for that address, then the packet is flooded to all  
ports in the VLAN. The responsibility for accepting or dropping the packets  
belongs to the hosts. If a multicast packet is received and there are ports  
registered to receive it, the packet is sent only to the registered ports.  
Cisco Small Business SG200 Series 8-port Smart Switch  
132  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Multicast  
Configuring MAC Group Addresses  
8
Forward All—All multicast packets received from a VLAN are flooded to all  
ports in the VLAN, regardless of port registrations to multicast addresses.  
Filter Unregistered—If a packet is received from a VLAN for a multicast  
destination address and no ports in the VLAN are registered to receive  
multicast packets for that address, then the packets are dropped.  
STEP 3 Click Apply. Your changes are saved to the Running Configuration.  
Configuring Multicast Properties on an Individual VLAN  
To configure a VLAN to have a different forwarding mode than the Global Multicast  
Mode setting:  
STEP 1 Select the VLAN from the VLAN ID menu and click Edit.  
STEP 2 Select the Multicast Mode as described in Configuring a Multicast Forwarding  
STEP 3 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
Configuring MAC Group Addresses  
The MAC Group Address page enables you to view and configure associations  
between multicast group MAC address and VLANs on the switch. You can  
configure static associations or they can be learned dynamically through IGMP or  
MLD snooping. When a packet is received for a multicast group address that  
matches an entry in the MAC Group Address Table, the packet is sent only to ports  
that are members of the VLAN.  
The switch supports up to 256 IPv4 and IPv6 MAC group address table entries,  
static and dynamic combined. A dynamic entry is aged out if no packets are  
received for the MAC group address for a configurable time (see the IGMP  
Snooping page to configure the IGMP Group Membership interval).  
Cisco Small Business SG200 Series 8-port Smart Switch  
133  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Multicast  
Configuring MAC Group Addresses  
8
Viewing the MAC Group Address Table  
To view the MAC Group Address Table, click Multicast > MAC Group Address in  
the navigation window.  
By default, all entries display in the table. You can use the VLAN ID and MAC Group  
Address filters to display only entries that match the specified values. The  
following fields display:  
Type—Indicates whether the entry is statically configured or dynamically  
learned.  
VLAN ID—VLAN ID to which multicast packets are forwarded when they  
match the specified multicast MAC address.  
MAC Group Address—Multicast group MAC address in hexadecimal format  
that is compared to an incoming packet destination MAC address.  
Adding a Static MAC Group Address Table Entry  
To add a static multicast MAC address and associate it with a VLAN:  
STEP 1 Click Add on the MAC Group Address page.  
STEP 2 Enter the parameters:  
VLAN ID—Select a VLAN from the list.  
Address Type—Select IPv4 to specify an address in 32-bit IPv4 notation  
(xxx.xxx.xxx.xxx), or select MAC to specify the address in a 6-byte  
hexadecimal format (xx.xx.xx.xx.xx.xx).  
MAC Group Address—Enter the address in the selected format. For an IPv4  
address, the least significant 23 bits are mapped to an Ethernet MAC  
address.  
STEP 3 Click Apply and then click Close. The entry appears in the MAC Group Address  
Table.  
Cisco Small Business SG200 Series 8-port Smart Switch  
134  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Multicast  
Configuring Group-to-Port  
8
Configuring MAC Address Group Port Membership  
By default, packets destined to a multicast MAC address are flooded on all ports.  
Ports might become members of a particular MAC address group dynamically  
through the exchange of IGMP packets, or you can statically configure them as  
members.  
To view details and configure the port members of a multicast group address:  
STEP 1 Select an entry on the MAC Group Address page and click Details.  
The page identifies the members of the multicast group address on every port.  
STEP 2 Click Static to configure a port as a static member of the multicast MAC address.  
Or click None to remove the port as a static member of the MAC Multicast  
Address.  
STEP 3 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
Configuring Group-to-Port  
The Group to Port page enables you to configure associations between VLANs  
and multicast group MAC address on the switch. You can configure static  
associations or they can be learned dynamically through IGMP or MLD snooping.  
(see the IGMP Snooping page to configure the IGMP Group Membership interval)  
The results can be displayed in the MAC Group Address Table.  
To configure Group to Port:  
STEP 1 Click Multicast > Group to Port in the navigation window.  
STEP 2 Use the VLAN ID and MAC Group Address filters to display entries that match the  
specified values:  
VLAN ID equals to—Select the VLAN ID to which multicast packets are  
forwarded when they match the specified multicast MAC address.  
MAC Group Address equals to—Select the group MAC address that is  
compared to an incoming packet destination MAC address.  
STEP 3 Select the Filter.  
Cisco Small Business SG200 Series 8-port Smart Switch  
135  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Multicast  
Configuring IGMP Snooping  
8
STEP 4 Set the type to indicate whether the entry is statically configured or dynamically  
learned. Ports can become members of a particular MAC address group  
dynamically through the exchange of IGMP packets, or you can statically configure  
them as members.  
STEP 5 Click Apply. Your changes are saved to the Running Configuration.  
Configuring IGMP Snooping  
Internet Group Management Protocol (IGMP) is a layer 3 Internet protocol that  
enables IPv4 networks to manage memberships to multicast groups. (IPv6  
multicast traffic is managed using the MLD protocol, as described in Configuring  
MLD Snooping.) IGMP communication occurs between IGMP routers and IGMP-  
enabled hosts (clients). Although the switch does not initiate or reply to IGMP  
packets, it can be configured to listen to IGMP communication between routers  
and clients that are connected by the switch, and to make forwarding decisions  
that help to reduce unnecessary network traffic.This listening behavior is referred  
to as IGMP snooping. This is particularly beneficial for high-bandwidth multicast  
network traffic.  
Ordinarily, when the switch receives broadcast or multicast packets, the switch  
forwards a copy into each of the remaining network segments. This approach  
works well for broadcast packets that are intended to be processed by all  
connected nodes. For multicast packets, however, this approach could lead to less  
efficient use of network bandwidth, particularly when the packet is intended for  
only a small number of nodes; packets are flooded into network segments where  
no node has an interest in receiving the packet.  
IGMP snooping enables the switch to intercept membership reports from IGMP  
clients and queries from routers. If the intercepted communications indicate that  
no IGMP clients exist on a link for a particular multicast destination address within  
a VLAN, then the switch does not send copies of those multicast packets to that  
network segment.  
IGMP snooping can be enabled or disabled on each VLAN. When enabled on a  
VLAN, IGMP snooping is performed on all interfaces that are members of that  
VLAN.  
Although IGMP is based on IP multicast addresses, the switch performs the actual  
multicast forwarding based on the equivalent MAC addresses.  
Cisco Small Business SG200 Series 8-port Smart Switch  
136  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Multicast  
Configuring IGMP Snooping  
8
To configure IGMP snooping:  
STEP 1 Click Multicast > IGMP Snooping in the navigation window.  
STEP 2 Select Enable for the IGMP Snooping Status.  
STEP 3 Click Add in the IGMP Snooping Table.  
STEP 4 For VLAN ID, select the VLAN that is to support IGMP snooping.  
STEP 5 Configure the following settings:  
IGMP Fast Leave—Select Enable to allow the switch to immediately remove  
a port (or LAG) from its multicast forwarding table when it receives an IGMP  
leave message for that multicast group. When enabled, the switch removes  
the port without first sending out general queries to the interface. Enable  
Fast Leave mode only on VLANs where only one host is connected to each  
port. This prevents the inadvertent dropping of the other hosts that are  
connected to the same port and remain interested in receiving multicast  
traffic directed to that group.  
IGMP Group Membership Interval—Specify the time in seconds that the  
switch waits for an IGMP membership report from a particular group on a  
particular interface before deleting the interface from the multicast  
forwarding database entry. Select Default to specify 260 seconds, or select  
User Defined and enter a value in the range 2 to 3600 seconds.  
IGMP Max Response Time—Specify the time in seconds that the switch  
waits for a reply after sending a query on an interface because it did not  
receive a report for a particular group in that interface. This value must be  
less than the IGMP Group Membership Interval value. Select Default to  
specify 10 seconds, or select User Defined and enter a value in the range 1  
to 25 seconds.  
IGMP MRouter Expiry Time—Specify the time in seconds that the switch  
waits for a query to be received on an dynamic mrouter interface before the  
interface is removed from the VLAN. A value of 0 indicates an infinite timeout;  
i.e., no expiration. Select Default to specify 0 seconds, or select User Defined  
and enter a value in the range 0 to 3600 seconds.  
STEP 6 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
The new VLAN entry appears in the IGMP Snooping Table.  
Cisco Small Business SG200 Series 8-port Smart Switch  
137  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Multicast  
Configuring MLD Snooping  
8
STEP 7 Ensure that an IGMP Mrouter interface has been configured for this VLAN (or all  
Configuring MLD Snooping  
MLD is a protocol used by IPv6 multicast routers to discover the presence of  
multicast listeners (nodes wishing to receive IPv6 multicast packets) on its  
directly-attached links and to discover which multicast packets are of interest to  
neighboring nodes. MLD is derived from IGMP, which performs a similar function  
for IPv4 multicast traffic (see Configuring IGMP Snooping).  
When MLD snooping is enabled, the switch selectively forwards IPv6 multicast  
packets to a list of ports that want to receive the data instead of flooding the  
packets to all ports in the VLAN. This list is constructed by snooping IPv6 multicast  
control packets.  
NOTE The switch supports MLD snooping of MLD version 1 and version 2 packets. The  
switch can be configured to perform MLD snooping and IGMP snooping  
simultaneously.  
MLD snooping can be enabled or disabled separately on each VLAN. Although  
MLD is based on IPv6 addresses, the switch performs the actual multicast  
forwarding based on the equivalent MAC addresses.  
To enable and configure MLD snooping:  
STEP 1 Click Multicast > MLD Snooping in the navigation window.  
The MLD Snooping Table lists each VLAN on which this feature is enabled.  
STEP 2 Select Enable for the MLD Snooping Status.  
STEP 3 Click Add in the MLD Snooping Table.  
Cisco Small Business SG200 Series 8-port Smart Switch  
138  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Multicast  
Configuring MLD Snooping  
8
STEP 4 For VLAN ID, select the VLAN that is to support MLD snooping.  
STEP 5 Enter the parameters:  
MLD Fast Leave Mode—Select Enable to allow the switch to immediately  
remove a port (or LAG) from its multicast forwarding table when it receives  
an MLD leave message for that multicast group. When enabled, the switch  
removes the port without first sending out MAC-based general queries to  
the interface. Enable Fast Leave mode only on VLANs in which only one host  
is connected to each port. This prevents the inadvertent dropping of the  
other hosts that are connected to the same port and remain interested in  
receiving multicast traffic directed to that group.  
MLD Group Membership Interval—Specify the time in seconds that the  
switch waits for an MLD membership report from a particular group on a  
particular interface before deleting the interface from the multicast  
forwarding database entry. Select Default to specify 260 seconds, or select  
User Defined and enter a value in the range 2 to 3600 seconds.  
MLD Max Response Time—Specify the time in seconds that the switch  
waits for a reply after sending a query on an interface because it did not  
receive a report for a particular group in that interface. This value must be  
less than the MLD Group Membership Interval value. Select Default to  
specify 10 seconds, or select User Defined and enter a value in the range 1  
to 65 seconds.  
MLD Mrouter Expiry Time—Specify the time in seconds that the switch  
waits for a query to be received on an interface before the interface is  
removed from the list of interfaces with an MLD multicast router attached. A  
value of 0 indicates an infinite timeout; i.e., no expiration. Select Default to  
specify 0 seconds, or select User Defined and enter a value in the range 0 to  
3600 seconds.  
STEP 6 Click Apply and then click Close.  
The new VLAN entry appears in the MLD Snooping Table.  
STEP 7 Ensure that an MLD Mrouter interface has been configured for this VLAN. See  
Cisco Small Business SG200 Series 8-port Smart Switch  
139  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Multicast  
Configuring IGMP Multicast Router Interfaces  
8
Configuring IGMP Multicast Router Interfaces  
An IGMP router must exist to manage the IGMP clients in a VLAN. For each VLAN  
that supports IGMP snooping, the switch must be statically configured with or  
must dynamically learn one or more interfaces where there is an IGMP router. An  
interface that has an IGMP router is known a IGMP Multicast router Interface. A  
VLAN that is IGMP snooping-enabled must have one or more IGMP multicast  
router interfaces. An IGMP multicast router can serve one or more VLANs.  
To enable a switch port or LAG as an IGMP Mrouter interface and to configure  
related settings:  
STEP 1 Click Multicast > IGMP Mrouter in the navigation window  
By default, the IGMP MRouter Table lists each switch port. To show LAGs, select  
LAG from the Interface Type list.  
STEP 2 Select the port or LAG that you want to configure and click Edit.  
STEP 3 Select Enable for the Mode.  
STEP 4 To specify the VLANs that use this interface as the IGMP Mrouter interface, move  
the VLAN to the Selected list, as described below.  
To select a VLAN: Click a VLAN in the Available list, and then click the right-  
arrow button to move it to the Selected list.  
To remove a VLAN: Click a VLAN in the Selected list, and then click the left-  
arrow button to move it to the Available list.  
STEP 5 Click Apply and then click Close.  
In the IGMP Mrouter Table, the interface displays Enable in the Mode column and  
lists the selected VLANs.  
Cisco Small Business SG200 Series 8-port Smart Switch  
140  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Multicast  
Configuring MLD Multicast Router Interfaces  
8
Configuring MLD Multicast Router Interfaces  
An MLD multicast router must exist to manage the MLD clients in a VLAN. For each  
VLAN that supports MLD snooping, the switch must be statically configured with  
or dynamically learn one or more interfaces where there is an MLD multicast  
router. The interface that has an MLD router is known a MLD Multicast router  
Interface. A VLAN that is MLD snooping-enabled must have one or more MLD  
multicast router interfaces. An MLD multicast router can serve one or more VLANs.  
To enable a switch port or LAG as an MLD Mrouter interface:  
STEP 1 Click Multicast > MLD Mrouter in the navigation window.  
By default, the MLD MRouter Table lists each switch port. To show LAGs, select  
LAG from the Interface Type list.  
STEP 2 Select the port or LAG to configure and click Edit.  
STEP 3 Select Enable for the Mode.  
STEP 4 Move VLAN IDs between the Available and Selected lists. VLANs in the Selected  
list use this port or LAG as the MLD Mrouter interface.  
To select a VLAN: Click a VLAN in the Available list, and then click the right-  
arrow button to move it to the Selected list.  
To remove a VLAN: Click a VLAN in the Selected list, and then click the left-  
arrow button to move it to the Available list.  
STEP 5 Click Apply and then click Close.  
In the MLD Mrouter Table, the interface displays Enable in the Mode column and  
lists the included VLANs.  
Cisco Small Business SG200 Series 8-port Smart Switch  
141  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
9
IP Configuration  
This chapter describes the Address Resolution Protocol (ARP) and Domain Name  
System (DNS) client features.  
It includes the following topics:  
ARP Table  
The switch maintains an Address Resolution Protocol (ARP) Table. Each entry in  
the table includes the IP address and the MAC addresses of a device that has  
recently communicated with the switch.  
You can use the ARP page to display ARP entries learned by the management  
VLAN. To display this page, click IP Configuration > ARP in the navigation window.  
You can click Clear ARP to delete all entries from the table, except for the  
management port IP address and MAC address.  
Domain Name System  
The switch supports IPv4 DNS client functionality. When enabled as a DNS client,  
the switch provides a hostname lookup service to other applications on the switch  
such as ping, RADIUS, syslog, Auto Configuration, and TFTP. The switch can be  
configured with DNS servers that resolve hostnames to IP addresses. The switch  
can also be configured with static host-name-to-IP-address mappings that bypass  
the DNS server.  
Cisco Small Business SG200 Series 8-port Smart Switch  
142  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
IP Configuration  
Domain Name System  
9
See the following topics for more information on the configuration pages available  
in the IP Configuration > Domain Name System menu.  
Configuring DNS Servers  
To resolve a hostname to an IP address, the client contacts one or more DNS  
servers. DNS servers can be learned dynamically if the management interface is  
configured as a DHCP client (see Management Interface). You can also use the  
DNS Servers page to statically configure DNS servers.  
DNS client functionality is enabled by default.  
Configuring Global DNS Settings  
To configure the DNS server mode and global settings:  
STEP 1 Click IP Configuration > Domain Name System > DNS Servers in the navigation  
window.  
STEP 2 Select Enable to implement DNS client functionality on the switch, if it is not  
already enabled.  
STEP 3 Enter the following parameters:  
Default Domain Name—Specify a domain name to be used to complete an  
unqualified hostname. For example, finance.yahoo.com is a fully qualified  
domain name. If only the unqualified hostname, finance, is specified, the  
default domain name yahoo.com would be appended, with a period in  
between. In your entry, do not include the period that separates the  
unqualified hostname from the domain name. The range is 1–255  
alphanumeric characters.  
Domain retry—Specify the number of times to retry sending DNS queries.  
The range is 0100 and the default value is 2 times.  
Domain timeout—Specify the time in seconds that the switch waits for a  
response to a DNS query. The range is 0–3600 seconds and the default is  
3 seconds.  
Cisco Small Business SG200 Series 8-port Smart Switch  
143  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
IP Configuration  
Domain Name System  
9
NOTE: Default domain names may be learned from reply messages from a DHCP  
server. These names display in the Default Domain Name List.  
STEP 4 Click Apply. Your changes are saved to the Running Configuration.  
Adding DNS Servers  
The DNS Servers Table lists the configured servers.  
To add a DNS server:  
STEP 1 Click Add.  
STEP 2 Specify the DNS server IPv4 or IPv6 address.  
STEP 3 Click Apply and then click Close. Your changes are saved to the Running  
Configuration and the server appears in the DNS Servers Table.  
Hostname Mapping  
Use the Host Mapping page to view and configure associations between  
hostnames and IP addresses. You can statically associate a hostname with an IP  
address. You can also view hostnames that have been learned dynamically  
through applications that use the DNS lookup service.  
NOTE If you configure a static hostname and IP address, and that same hostname IP  
address mapping is later learned from DNS, the entry becomes dynamic and it is  
no longer saved as a static entry in the the Running Configuration.  
Configuring Static DNS Mappings  
The Host Mapping Table lists hostnames that are statically assigned to IP  
addresses on the switch. To configure a static hostname mapping:  
STEP 1 Click IP Configuration > Domain Name System > Host Mapping in the navigation  
window.  
STEP 2 Click Add.  
STEP 3 Enter a hostname from 1–255 alphanumeric characters. The hostname must begin  
with a letter.  
STEP 4 Enter an IPv4 or IPv6 address to be associated with the hostname.  
Cisco Small Business SG200 Series 8-port Smart Switch  
144  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
IP Configuration  
Domain Name System  
9
STEP 5 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
Viewing and Deleting Dynamic DNS Entries  
The DNS Dynamic Entries table displays hostnames that have been learned by  
applications that use DNS lookup services. For example, if you ping a hostname,  
the DNS lookup service is invoked and an associated IP address is learned and  
added to the table.  
The DNS Dynamic Entries table displays the following fields:  
Hostname—Host name assigned to the IP address (or to an official  
hostname).  
Total—Number of minutes the hostname has been reserved for this  
assignment.  
Elapsed—Number of minutes that have elapsed since the hostname was  
assigned.  
Type—Identifies the hostname as one of the following:  
-
-
IP Address—The assigned hostname is associated with an IP address.  
Canonical—The assigned hostname is an alias or nickname for a  
properly denoted (official) hostname. For example, www.google.com  
might be a hostname alias associated with the official hostname  
www.l.google.com.  
Addresses—If the Type is IP, this field displays the IPv4 address or the IPv6  
address that is associated with the hostname. If the Type is Canonical, this  
field displays the canonical hostname that the alias is associated with. A  
canonical DNS address might have more than one hostname alias  
associated with it.  
To delete a dynamic entry, select it and click Delete. To delete all dynamic entries  
from the table, click Delete All Dynamic Entries.  
Cisco Small Business SG200 Series 8-port Smart Switch  
145  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
10  
Security  
This chapter describes the security features for the port, user, and server.  
It includes the following topics:  
RADIUS  
The switch supports Remote Authorization Dial-In User Service (RADIUS) client  
functionality. RADIUS has become the protocol of choice by administrators of  
large accessible networks for authenticating users prior to access. To authenticate  
users in a secure manner, a RADIUS client and RADIUS server are configured with  
the same shared password or secret. This secret is used to generate one-way  
encrypted authenticators that are present in all RADIUS packets. Without  
knowledge of the secret, the possibility of a malicious user correctly spoofing  
packets is sufficiently reduced.  
The RADIUS client on the switch is used for switch management access  
authentication and IEEE 802.1X (dot1X) port access control (see Management  
You can use the RADIUS page to configure global RADIUS settings and add  
RADIUS servers.  
Cisco Small Business SG200 Series 8-port Smart Switch  
146  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Security  
RADIUS  
10  
Configuring Global RADIUS Settings  
To configure the global settings:  
STEP 1 Click Security > RADIUS in the navigation window.  
STEP 2 Enter the parameters:  
Retries—Maximum number of times the RADIUS client retransmits requests  
to the RADIUS server. The range is 1 to 10. The default is 3.  
Timeout for Reply—Number of seconds the switch waits for a RADIUS  
server to reply to a server request before sending another request. The  
range is 1 to 30. The default is 3.  
Dead Time—Length of time a RADIUS server is bypassed once the switch  
determines it is unavailable. Bypassing unavailable switches improves  
switch response times. The range is 0 to 2000. The default is 0.  
RADIUS Attribute 4 (NAS-IP Address)—Select to enable the switch to  
include the network access server (NAS) attribute in Access Request  
RADIUS server packets. If this option is disabled, the RADIUS client uses the  
switch management port address as the NAS-IP Address.  
NAS-IP Address—IP address to include in Access Request packets. This  
field is editable only when RADIUS Attribute 4 is enabled. The address  
should be unique to the NAS within the scope of the RADIUS server.  
NOTE: The Current RADIUS Server field displays the IP address of the most  
recently configured RADIUS server, if any.  
STEP 3 Click Apply. Your changes are saved to the Running Configuration.  
Adding a RADIUS Server  
You can configure multiple RADIUS servers and configure priority levels that  
determine the order they are contacted.  
!
CAUTION All management users are created with read-write permissions. Ensure that all  
RADIUS server users you configure have the same privilege levels; otherwise they  
are not granted access to the switch.  
Cisco Small Business SG200 Series 8-port Smart Switch  
147  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Security  
RADIUS  
10  
To add a RADIUS Server to the RADIUS Table:  
STEP 1 Click Add  
STEP 2 Enter the parameters:  
RADIUS Server—IP address or hostname of the server.  
Priority—The lower the priority number value, higher the priority of the  
server. For example, server configured with priority value 1 has higher  
priority than server configured with priority value 2. If all the servers are  
configured with the same or the default priority value, the switch tries the  
RADIUS servers in a first-come, first served basis. The range is 1 to 65535.  
The default is 8.  
Key String—A shared secret text string used for authenticating and  
encrypting all RADIUS communications between the switch and the RADIUS  
server. This secret must match the secret configured on the RADIUS server.  
This must be an ASCII alphanumeric value between 32 to 176 characters.  
Authentication Port—Port number used for RADIUS authentication  
requests and replies. The default port, 1812, is the well-know IANA port  
number for RADIUS authentication services. The range is 1025 to 65535.  
The default is1812.  
Message Authenticator—This field is selected by default. When enabled,  
the message authenticator attribute is included in RADIUS request  
messages to the server. This attribute protects the RADIUS messages from  
spoofing and tampering. The shared secret is used as the key. If the RADIUS  
Message Authenticator attribute is present in the packet, it is verified by the  
server. If verification fails, the server drops the request packet.  
STEP 3 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
Cisco Small Business SG200 Series 8-port Smart Switch  
148  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Security  
Password Strength  
10  
Password Strength  
You can use the Password Strength page to configure characteristics of secure  
management user passwords.  
To configure password strength settings:  
STEP 1 Click Security > Password Strength in the navigation window.  
STEP 2 Enter the following parameters:  
Strength Check—Select Enable to configure the types of checks to be  
performed:  
Minimum Password Length—The minimum number of characters required  
for a management user password. Set the minimum password length to a  
value in the range of 0–64 characters.  
Password Aging Time—Select the checkbox and enter the time after which  
a password expires, from 1–365 days. When a password ages out, the user  
must chose a new password before continuing.  
Password Exclude Keyword Check—Select Enable to check for  
preconfigured keywords in a password when a user attempts to create or  
change the password. The preconfigured keywords are cisco and ocsic.  
Password User Name Check—Select Enable to prevent users from  
including their user name in their password when they create or change it.  
Character Can Repeat Itself Consecutively a Maximum of 3 Times—  
Select Enable to have the switch check whether any character in the  
password is repeated consecutively more than three times.  
Minimum Number of Character Classes—Select the checkbox and enter  
the minimum number of character classes that must be represented in the  
password string. The four possible character classes are: uppercase letters,  
lowercase letters, numbers, and special characters available on a standard  
keyboard.  
STEP 3 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
Cisco Small Business SG200 Series 8-port Smart Switch  
149  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Security  
Management Access Profile Rules  
10  
Management Access Profile Rules  
Use the Management Access Profile Rules page to define a profile and rules for  
accessing the device for management purposes.  
You can limit access to specific user names, ingress ports or LAGs, and source IP  
addresses.  
To display this page, click Security > Management Access Profile Rules in the  
navigation window.  
The Access Profile Table lists the profile name of the currently configured profile, if  
one exists. The Profile Rule Table shows the existing rules for the profile. By  
default, no access profiles and rules are configured on the switch. You can create  
and enable only one profile and all the rules you create are assigned to that profile.  
Configuring an Access Profile and Rules  
To create an access profile and assign rules to it:  
STEP 1 In the Access Profile Table, click Add.  
STEP 2 Specify the Access Profile Name and select Enable.  
STEP 3 Click Apply and then click Close.  
The new profile appears in the Access Profile Table. Next, add the rules to the  
profile.  
STEP 4 In the Profile Rule table, click Add.  
STEP 5 Specify any of the following parameters to restrict or allow access:  
Rule Priority—The rules are validated against the incoming management  
request in the ascending order of their priorities. If a rule matches, the  
specified action is performed and rules below are ignored. For example, if  
you configure Source IP 10.10.10.10 with priority 1 to Permit, and configure  
Source IP 10.10.10.10 with priority 2 to Deny, then access is permitted to this  
IP address when the profile is active, and the second rule is ignored. The  
range is 1 to 16, with 1 having the highest priority.  
Cisco Small Business SG200 Series 8-port Smart Switch  
150  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Security  
Management Access Profile Rules  
10  
To limit access to the web-based switch configuration utility only to  
specified users, for example, you can create a rule in which HTTP access is  
denied to all users, and then create another rule in which specific users are  
permitted. The rule that permits the specific users must have a higher Rule  
Priority than the rule that denies all users.  
CAUTION: If a profile is activated that denies access to an intranet or domain  
where a current web management session is active, the session remains  
active until logout or timeout. Future sessions are blocked by the profile.  
Active sessions using Internet Explorer 8 are terminated immediately unless  
the switch management IP address is added to the Local Intranet Sites list in  
Utility for instructions.  
Action—Select the action to be performed when the rules criteria is  
matched.  
-
Permit—The specified interface, user, or IP address is permitted access  
to the switch that would otherwise be explicitly forbidden by a deny rule.  
-
Deny—The specified interface, user, or IP address is denied access to  
the switch.  
Applies to Interface—Select All to apply this rule to all interfaces (ports and  
LAGs). Or, select User Defined and select the port or LAG that the rule  
applies to.  
Applies to User—Select All to apply this rule to all system users. Or, select  
User Defined and select a User Name that the rule applies to.  
Applies to Source IP Address—Select All to apply the rule to any source IP  
addresses. Or select User Defined and specify a source IPv4 address and  
mask that this rule applies to.  
STEP 6 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
The new rule appears in the Profile Rule Table. You can select the rule and click  
Edit to modify it or click Delete to remove it from the access profile.  
NOTE User cisco will not be denied management access.  
Cisco Small Business SG200 Series 8-port Smart Switch  
151  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Security  
Management Access Profile Rules  
10  
Modifying and Deleting Access Profiles and Rules  
Before you can delete an Access Profile or modify the rules, you must disable the  
profile.  
To disable an access profile:  
STEP 1 Select the profile in the Access Profile Table and click Edit.  
STEP 2 Uncheck the Enable box.  
STEP 3 Click Apply, and then click Close.  
When you finish making changes, re-enable the access profile.  
To delete an access profile (after disabling it):  
STEP 1 Select the profile in the Access Profile Table.  
STEP 2 Click Delete.  
To delete a profile rule (after disabling the access profile):  
STEP 1 Select the rule in the Profile Rule Table.  
STEP 2 Click Delete.  
To modify a profile rule (after disabling the access profile):  
STEP 1 Select the rule in the Profile Rule Table and click Edit.  
STEP 2 Enter the new settings.  
STEP 3 Click Apply, and then click Close.  
To enable an access profile (after completing all changes):  
STEP 1 Select the profile in the Access Profile Table and click Edit.  
STEP 2 Check the Enable box.  
Cisco Small Business SG200 Series 8-port Smart Switch  
152  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Security  
Authentication Methods  
10  
STEP 3 Click Apply, and then click Close.  
Authentication Methods  
You can use the Authentication Methods page to specify how users are allowed  
access to switch ports.  
To select the authentication method:  
STEP 1 Click Security > Authentication Methods in the navigation window.  
STEP 2 an authentication method from the list:  
Local—A user ID and password combination from the supplicant is  
compared with a locally-stored user database on the switch.  
None—No authentication method is used.  
RADIUS—Authentication requests are passed to a RADIUS server that  
replies with RADIUS Access-Accept or Access-Reject frames. If the switch  
cannot reach the server, the request is denied.  
RADIUS, None—Authentication requests are passed to a RADIUS server  
that replies with RADIUS Access-Accept or Access-Reject frames. If the  
switch cannot reach the server, then no authentication method is used and  
the request is accepted.  
RADIUS, Local—Authentication requests are passed to a RADIUS server. If  
the switch cannot reach the server, the local user database is used to accept  
or reject the request.  
NOTE When the (Radius, None) or the (Radius, Local) option is selected,  
None or Local is used only if the Radius Server specified is incorrect or it is  
not specified; if it is correct, but the credentials are incorrect, the  
authentication fails and does not fall back to the None or the Local option.  
STEP 3 Click Apply. Your changes are saved to the Running Configuration.  
Cisco Small Business SG200 Series 8-port Smart Switch  
153  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Security  
Storm Control  
10  
Storm Control  
A traffic storm is the result of an excessive number of broadcast, multicast, or  
unknown unicast messages simultaneously transmitted across a network by a  
port. Forwarded message responses might create a loop and overload network  
resources and cause the network to time-out.  
The switch measures the incoming broadcast, multicast, or unknown unicast  
packet rate per port and discards packets when a rate exceeds a defined value.  
Storm control can be enabled or disabled on each interface.  
Storm control is disabled by default on all ports for all packet types. Use the Storm  
Control page to enable and configure storm control on the switch ports.  
To display and configure storm control settings for a port:  
STEP 1 Click Security > Storm Control in the navigation window.  
STEP 2 Select the port to configure and click Edit.  
STEP 3 For broadcast, multicast, and unicast traffic, specify the following storm control  
parameters for the selected port:  
Mode—Select Enable to turn on storm control protection for the traffic type.  
Rate Threshold Type—Select the measurement the switch uses to  
determine whether traffic exceeds the threshold:  
-
-
Percent—Traffic is dropped when it exceeds a percentage of the total  
capability of the link.  
pps (packets per second—Traffic is dropped when it exceeds the set  
number of packet-per-second on the link for this type of traffic.  
Rate Threshold—Specify the maximum rate at which this type of packet is  
forwarded. If the Rate Threshold Type is Percent, enter a percentage of the  
total port capability (0100 percent). If the Rate Threshold Type is pps, enter  
a packet per second rate (014880000). Ports that operate at 10 Mbps,  
100 Mbps, or 1000 Mbps have a maximum throughput of 14880, pps  
148800 pps, or 1488000 pps correspondingly.  
Cisco Small Business SG200 Series 8-port Smart Switch  
154  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Security  
Port Security  
10  
NOTE: The actual rate of ingress traffic required to activate Storm Control is  
based on the actual size of incoming packets and the hard-coded average  
packet size (512 bytes) parameter. A packet-per-second rate is calculated,  
as the switch requires a pps value to execute or not execute storm control  
versus an absolute data rate measured in kilobits-per-second (kbps). For  
example, if the configured pps limit for broadcast packets is 10 percent, this  
value is converted to approximately 20000 pps for a 100 Mbps port.  
STEP 4 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
Port Security  
You can enable port security on a per-port basis. When a port is secured (locked),  
the switch forwards only those packets with a source MAC address that is  
secured at the port. All other packets are discarded. This includes discarding any  
packet from a port with a source MAC address that is secured at another port.  
A secure MAC address can be statically configured or dynamically learned. The  
maximum number of secure MAC addresses at a secured port is 256. Static  
secure MAC addresses are configured using the Static Addresses page. Both  
static and dynamic secure MAC addresses are subject to aging limits (see  
To display the Port Security page, click Security > Port Security in the navigation  
window.  
The Port Security Table shows the current security configuration for each port.  
You can select LAG from the Interface Type list to display data for LAGs only. By  
default, port security is disabled globally and on each interface.  
Enabling Port Security  
To configure port security:  
STEP 1 On the Port Security page, select Enable for the global Admin Mode and click  
Apply.  
STEP 2 Select the port or LAG to configure and click Edit.  
STEP 3 Configure the following settings:  
Cisco Small Business SG200 Series 8-port Smart Switch  
155  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Security  
Port Security  
10  
Interface Status—Select Lock to enable port security on the interface.  
When an interface transitions from unlocked to locked, all addresses that  
had been dynamically learned by the switch on that port are removed from  
its MAC address list.  
Max No. of Static MAC Addresses—Specify the maximum number of static  
secure MAC addresses at the port/LAG. Static secure MAC address are  
configured on the Static Addresses page. The total number of secure  
addresses cannot exceed 256.  
Max No. of Dynamic MAC Addresses—Specify the maximum number of  
dynamic secure MAC addresses that can be learned from the port/LAG. The  
total number of secure addresses cannot exceed 256.  
When port-security is enabled on a port, and static or dynamic limits are set  
to new values, the following rules apply:  
-
If the new value is greater than the old value, no action is taken for either  
the dynamic or static addresses.  
-
If the new value is less than the old value, the following actions are taken:  
Dynamic Addresses—The switch initiates a flush of all learned  
addresses on the port.  
Static Addresses—The switch retains the static addresses (up to the  
static limit) regardless of whether the addresses are configured as  
secure, permanent, or delete on timeout. It then deletes the remaining  
static addresses from the MAC address table.  
Action on Violation—Select how the switch handles incoming packets that  
are not allowed on the locked port:  
-
-
Discard—Packets are dropped.  
Forward—Packets are forwarded, but the source MAC addresses are  
not added to the forwarding database.  
-
Shutdown—Packets are discarded and the port is shut down.  
Trap Frequency—Specify the number of seconds between traps when a  
locked port receives incoming packets that are not allowed on the port. This  
field displays only when the Action of Violation field is set to Discard with  
Trap.  
Convert dynamic addresses to static—Select Enable to convert all  
dynamic secure MAC addresses to static secure MAC addresses.  
Cisco Small Business SG200 Series 8-port Smart Switch  
156  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Security  
802.1X  
10  
Reset Port—Select to reset the port if it has been shut down by the Port  
Security feature.  
STEP 4 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
Viewing and Configuring Secure MAC Addresses  
To view the current list of secure MAC addresses, associated ports, and VLANs,  
click Secure Address Table on the Port Security page.  
For each interface, the Secure Address Table lists each secured statically  
configured MAC address, regardless of the locked or unlocked status of the port.  
The table also lists dynamically learned MAC addresses for locked ports. Dynamic  
entries for a port are cleared when the port is changed from locked to unlocked or  
when the link goes down.  
You can click Static Address Table to display the page for configuring static  
addresses. See Configuring Static MAC Addresses. Be sure to set the Status  
field for the entry to Secure.  
You can click Port Security Table to redisplay the Port Security page.  
802.1X  
Local Area Networks (LANs) are often deployed in environments that permit  
unauthorized devices to be physically attached to the LAN infrastructure, or permit  
unauthorized users to attempt to access the LAN through equipment already  
attached. In such environments, it might be desirable to restrict access to the  
services offered by the LAN to those users and devices that are permitted to use  
those services.  
Port-based access control provides a method for networks to control whether  
hosts can access services provided by a connected port. You can configure the  
switch to use port-based network access control based on the IEEE 802.1x  
protocol.  
The 802.1x protocol defines three types of entities:  
Supplicant: An entity that requests access to a port at the remote end of the  
link. The supplicant provides credentials to the network that another node  
Cisco Small Business SG200 Series 8-port Smart Switch  
157  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Security  
802.1X  
10  
on the network—the authenticator—uses to request authentication from a  
server.  
Authenticator: An entity that facilitates the authentication of the supplicant  
on the remote end of a link. An authenticator grants port access to a  
supplicant if the authentication succeeds.  
Authentication Server: A server, such as a RADIUS server, that performs the  
authentication on behalf of the authenticator, and indicates whether the  
supplicant is authorized to access services provided via the authenticating  
port.  
In the authentication process, 802.1X supports Extensible Authentication Protocol  
(EAP) over LANs (EAPOL) message exchanges between supplicants and  
authenticators.  
A switch port can be configured either as an authenticator or a supplicant, but not  
both.  
See the following topics for more information on the configuration pages available  
in the Security > 802.1X menu.  
Defining 802.1X Properties  
Use the 802.1X Properties page to configure the global 802.1X administrative  
mode on the switch.  
To enable 802.1X security globally:  
STEP 1 Click Security > 802.1X > Properties in the navigation window.  
STEP 2 Select Enable for the Port Based Authentication State to allow 802.1X port-based  
authentication globally on the switch.  
STEP 3 Select an authentication method from the Authentication Method list:  
None—No authentication method is used.  
Cisco Small Business SG200 Series 8-port Smart Switch  
158  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Security  
802.1X  
10  
Local—The switch performs local authentication of a remote supplicant  
based on EAP-MD5. The supplicant identification must be one of the  
management users configured on the switch (see Managing User  
RADIUS—The switch depends on one or more external RADIUS servers to  
perform the authentication. You must configure the supplicant identity and  
authentication directly the servers. (See RADIUS for information.)  
RADIUS, None—The switch depends on one or more external RADIUS  
servers to perform the authentication. (See description of RADIUS above.) If  
the switch cannot reach any servers, then no authentication is used.  
RADIUS, Local—The switch depends on one or more external RADIUS  
servers to perform the authentication (see description of RADIUS above.) If  
the switch cannot reach any servers, it performs the authentication locally  
(see previous description of Local).  
NOTE When the (Radius, None) or the (Radius, Local) option is selected,  
None or Local is used only if the Radius Server specified is incorrect or it is  
not specified; if it is correct, but the credentials are incorrect, the  
authentication fails and does not fall back to the None or the Local option.  
STEP 4 Click Apply. Your changes are saved to the Running Configuration.  
NOTE See Modifying Port PAE Capabilities for instructions on selecting the role for  
individual ports, and Configuring Port Authentication for instructions on  
configuring authentication on individual ports.  
Modifying Port PAE Capabilities  
Use the Port PAE Capabilities page to view and configure each port’s 802.1X role  
as authenticator or supplicant.  
To modify the role of a port as an authenticator or supplicant:  
STEP 1 Click Security > 802.1X > Port PAE Capabilities in the navigation window.  
STEP 2 Select the port to configure and click Edit.  
Cisco Small Business SG200 Series 8-port Smart Switch  
159  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Security  
802.1X  
10  
STEP 3 Select the role for the port:  
Authenticator—Select this option if the port must authenticate the remote  
supplicant before granting access to a local port.  
Supplicant—Select this option if the port must be connected to an  
authenticator and ask permission from the remote authenticator before  
accessing a remote port. When a port is acting as a Supplicant, the user  
name and password defined in the User Accounts list of the switch must be  
entered in the Radius Server for the authentication to succeed.  
STEP 4 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
Configuring Port Authentication  
Use the Port Authentication page to configure port access control on ports that  
serve as authenticators. By default, all ports are set to Authenticator. To enable a  
port as an authenticator, see Modifying Port PAE Capabilities.  
To edit a port authenticator settings:  
STEP 1 Click Security > 802.1X > Port Authentication in the navigation window.  
The Port Authentication Table displays the current configuration of each port.  
STEP 2 Select the port to configure and click Edit.  
STEP 3 Enter the parameters:  
Local Database User Name—Use the left and right arrows to move the  
configured management users to the Available or Selected lists. Only users  
in the Selected list have access to the port, subject to authentication. This list  
is applicable only when the authentication is local, and not when a RADIUS  
server is used for authentication.  
Current Port Control—The current authorization status of the port  
(Authorized or Unauthorized).  
Administrative Port Control—Select the port authorization mode. The  
possible values are:  
-
Force Unauthorized—Select this option to always deny port access by  
supplicants attaching to the port. If selected, the port control status  
becomes Unauthorized.  
Cisco Small Business SG200 Series 8-port Smart Switch  
160  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Security  
802.1X  
10  
-
-
auto—Select this option if the port control is based on the result of the  
authentication process. If the supplicant is authenticated, the port control  
status becomes Authorized, meaning the supplicant is granted access to  
the port. If the supplicant is not authenticated, the port control status  
becomes Unauthorized, meaning the supplicant is denied access.  
Force Authorized—Select this option to always allow port access if  
authentication of remote supplicants is not required. If selected, the port  
control status will be Authorized.  
Periodic Reauthentication—Select this option if the port is to re-  
authenticate its supplicant periodically. The port will reauthenticate at the  
scheduled interval, even if it has remained authenticated.  
Reauthentication Period—The interval between reauthentication attempts.  
The range is 300–65535 seconds. The default is 3600 seconds.  
Reauthenticate Now—Forces immediate port reauthentication, when  
selected.  
Authenticator State—The current port authorization state. Possible states  
are: Initialize, Disconnected, Connecting, Authenticating, Authenticated,  
Aborting, Held, Force Authenticate, and Force Unauthenticate.  
Quiet Period—Amount of time that the switch remains in the quiet state  
following a failed authentication exchange. During the quiet period, the  
switch does not accept or initiate authentication requests. Change the  
default value of this command only to adjust for unusual circumstances, such  
as unreliable links or specific behavioral problems with certain clients and  
authentication servers. To provide a faster response time to the user, enter a  
smaller number than the default (60 seconds). The range is 0–65535  
seconds.  
Resending EAP—The amount of time that lapses before EAP requests are  
resent. The range is 1–65535 seconds and the default is 30 seconds.  
Supplicant Timeout—The amount of time that lapses before EAP requests  
are resent to supplicants. Change the default value of this command (30  
seconds) only to adjust for unusual circumstances, such as unreliable links or  
specific behavioral problems with certain clients and authentication servers.  
To provide a faster response time to the user, enter a smaller number than the  
default. The range is 1–65535 seconds.  
Server Timeout—The amount of time that lapses before the switch resends  
a request to the authentication server. The range is 1–65535 seconds and  
the default is 30 seconds.  
Cisco Small Business SG200 Series 8-port Smart Switch  
161  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Security  
802.1X  
10  
Max EAP Requests—The preconfigured maximum number of times the  
switch can send an EAP request before restarting the authentication process  
if it does not receive a response.  
Termination Cause—The reason for termination.  
STEP 4 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
Configuring Supplicant Port Authentication  
Use the Supplicant Port Authentication page to configure port access control on  
ports that are configured in the supplicant role. To enable a port as an supplicant,  
To configure supplicant port authentication:  
STEP 1 Click Security > 802.1X > Supplicant Port Authentication in the navigation  
window.  
STEP 2 Select the port to configure and click Edit.  
The Current Port Control field shows the current authorization mode for the port.  
STEP 3 Configure the following:  
Administrative Port Control—Select the port authorization mode. The  
possible values are:  
-
Force Unauthorized—Denies the selected interface system access by  
moving the interface into unauthorized state.  
-
Auto—The switch detects the mode of the interface based on the  
outcome of authentication exchanges between the supplicant, the  
authenticator, and the authentication server.  
-
Force Authorized—The port is placed into an authorized state without  
requiring authentication with the authentication server. The interface  
sends and receives normal traffic without client port-based  
authentication.  
Cisco Small Business SG200 Series 8-port Smart Switch  
162  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Security  
802.1X  
10  
User Name—Select the user to be used by the port to identify itself as a  
supplicant. The user must be one of the switch management users  
configured in the switch. The password configured for the user will be used  
in the authentication process. As a supplicant, the switch supports EAP-MD5  
authentication method. (See Managing User Accounts to set up the users.)  
STEP 4 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
Displaying Authenticated Hosts  
To display ports that have authenticated users on the Authenticated Hosts page,  
click Security > 802.1X > Authenticated Hosts in the navigation window.  
The Authenticated Hosts Table displays the following information for each host:  
Port—Port used for authentication.  
User Name—User name of the host.  
Supplicant MAC Address—Supplicant device MAC address.  
Session Time—Time since the supplicant logged in.  
Session Timeout—Time that the given session is valid. The time period in  
seconds is returned by the RADIUS server on authentication of the port.  
Authentication Method:  
-
Local—A user ID and password combination from the supplicant was  
compared with a locally-stored user database on the switch. Or the  
switch could not reach a server and the local user database was used to  
accept or reject the request.  
-
-
None—No authentication method was used. Or the switch attempted to  
could not reach the server, and no authentication method was used and  
the request was accepted.  
RADIUS—Authentication requests are passed to a RADIUS server that  
replies with RADIUS Access-Accept or Access-Reject frames. If the  
switch cannot reach the server, the request is denied.  
Cisco Small Business SG200 Series 8-port Smart Switch  
163  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
11  
Quality of Service  
This chapter describes the QoS features of the device.  
QoS is a means of providing consistent, predictable data delivery by  
distinguishing packets that have strict timing requirements from those that are  
more tolerant of delay. Packets with strict timing requirements are given special  
treatment in a QoS-capable network.  
Each physical port on a switch has one or more queues for transmitting packets to  
the attached network. Multiple queues per port are often configured to give  
preference to certain packets over others based on a user-defined criteria. When  
a packet is queued for transmission in a port, the rate at which it is serviced  
depends on how the queue is configured and, possibly, the amount of traffic  
present in the other queues for the port.  
If a delay is necessary, packets get held in the queue until the scheduler authorizes  
the queue for transmission. If a queue is full, packets have no place to be held for  
transmission and might be dropped by the switch.  
In networks where QoS operation is enabled, all elements of the network must be  
QoS-capable. The presence of one or more nodes that are not QoS-capable  
creates a deficiency in the network path and the performance of the entire packet  
flow is compromised.  
Cisco Small Business SG200 Series 8-port Smart Switch  
164  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quality of Service  
QoS Properties  
11  
The switch supports four egress queues for each port or LAG. Queue1 has the  
lowest priority and queue 4 has the highest priority.  
The pages in the Quality of Service menu enable you to define the properties of  
the queues, and to associate to the queues the traffic that has particular  
characteristics or arrives on specific interfaces. You can also create rate limit  
profiles that define criteria for determining if a port is receiving more traffic than it  
can handle. You can then assign the rate limit profiles to ports.  
QoS Properties  
You can configure switch ports to assign traffic to egress queues based on the  
priority information encoded in Ethernet frames or IP packet headers. Or traffic  
might use a default priority value configured on the port where it arrives. When a  
port is configured to use the encoded priority value [such as the 802.1p, IP  
precedence, or DSCP (Differentiated Services Code Point) value], it is considered  
a trusted port. A port that is configured to use its own priority value, rather than the  
value encoded in the frame or packet, to make queue assignment decisions is  
considered untrusted.  
If a port is configured as trusted but the frame or packet does not have priority  
information, the default port priority is assigned to the packet. The default port  
priority is zero.  
You can use the Interface Settings page to change the value of the VLAN Priority.  
You can use the QoS Properties page to define a port as trusted or untrusted and  
to configure which priority values it trusts.  
To configure the trust mode on a port or LAG:  
STEP 1 Click Quality of Service > QoS Properties in the navigation window.  
STEP 2 Select a filter from the Interface Type menu to display ports or LAGs in the Trust  
Mode Configuration Table.  
STEP 3 Select the interface to configure and click Edit.  
STEP 4 To specify the type of priority values to use to determine the egress queues of the  
packets, select one of the following trust modes:  
untrusted—The port assigns its own default 802.1p priority (0).  
trust dot1p—The port uses the 802.1p priority value in VLAN-tagged  
Ethernet frames. For untagged frames, the default priority is assigned.  
Cisco Small Business SG200 Series 8-port Smart Switch  
165  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Quality of Service  
Defining Queues  
11  
trust ip-precedence—The port uses the IP Precedence value in the IP  
packet header. If no value is provided, the default priority is assigned. Non-IP  
VLAN tagged and untagged frames are assigned the default priority.  
trust ip-dscp—The port uses the DSCP marking in the IP packet header for  
both VLAN tagged and untagged IP packets. Non-IP VLAN tagged and  
untagged frames are assigned the default priority.  
trust all—For IP packets, the port uses the DSCP marking to determine the  
priority. For non-IP frames, the port uses the 802.1p priority if the frame is  
VLAN-tagged and the port default priority if the frame is not VLAN tagged.  
STEP 5 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
Defining Queues  
You can use the Queue page to configure how the traffic scheduler determines  
which queue has access to the egress port. A queue can be configured in strict  
priority mode or Weighted Round-Robin (WRR) mode. By default, all queues are  
strict priority queues.  
Packets are transmitted according to the following principles:  
Packets from the highest priority queue are transmitted first.  
If a queue is in strict priority mode, it is allowed to transmit until it has no  
more packets or until a higher priority queue has packets to send.  
If a queue is in WRR mode, it is allowed to transmit a number of packets that  
is proportional to its configurable weight value. The weight is expressed as  
a percentage of the total bandwidth for each port.  
A combination of strict queue and WRR queues can be configured at a port.  
Cisco Small Business SG200 Series 8-port Smart Switch  
166  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quality of Service  
Defining Queues  
11  
Queue Configuration Recommendations  
It is recommended that higher numbered queues be configured with higher  
priority, weight, and minimum-bandwidth settings.  
The following are recommended scenarios for strict priority (SP) and WRR  
queues:  
All eight queues in SP mode (q8 > q7 > q6 > q5 > q4 > q3 > q2 > q1). q8 is  
allocated bandwidth as long as there are packets to serve in q8. Then Q7 is  
served, followed by Q6, and so forth.  
All 8-queues in WRR mode (q8:q7:q6:q5:q4:q3:q2:q1 = A:B:C:D:E:F:G:H). In  
this mode, each queue is allocated its minimum bandwidth according to the  
weights configured.  
One queue in SP mode and all other queues in WRR mode (q8 > q7/q6/.../  
q1 and q7::q1 = A::G). In this scenario q8 is configured in SP mode and q7  
through q1 in WRR mode.  
Four queues in SP mode and four queues in WRR mode (q8 > q7 > q6 >  
q5 > q4/q3/q2/q1 and q4/q3/q2/q1 = A:B:C:D): In this scenario q8, q7, q6, and  
q5 are configured in strict mode with q4, q3, q2 and q1 in WRR mode.  
When there are more ingress ports with traffic destined to different queues on  
egress ports, a system might encounter a Head of Line Blocking (HOL) condition.  
HOL could result in higher numbered queues getting more bandwidth, although  
higher numbered queues are configured with lower bandwidth and weight. It is  
always recommended that higher numbered queues with higher weight be  
configured in SP mode, so that even in a HOL condition, the desired egress  
segregation is achieved.  
Configuring Queues  
To configure QoS properties:  
STEP 1 Click Quality of Service > Queue in the navigation window.  
STEP 2 Select from the Interface drop-down menus the Port or the LAG to configure.  
STEP 3 Select one of the following modes for each queue on the selected interface:  
Strict Priority—Select to have the scheduler forward traffic strictly based  
on the priority levels in the queues. The queue with the highest priority traffic  
has access to the egress port until all such traffic is forwarded. Strict priority  
mode provides low-latency service to higher priority classes of traffic.  
Cisco Small Business SG200 Series 8-port Smart Switch  
167  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Quality of Service  
Mapping CoS/802.1p Priorities to Queues  
11  
WRR—Select to have the scheduler service the queue in turn with other  
WRR queues, based on bandwidth percentage of the queue relative to other  
WRR queues. (Strict queues continue to be serviced for as long as they have  
higher priority traffic.)  
STEP 4 If you selected WRR mode for a queue, enter a bandwidth percentage in the  
Percentage of WRR Bandwidth field. The total of all bandwidth percentages for all  
queues cannot exceed 100 percent.  
STEP 5 Click Apply. Your changes are saved to the Running Configuration.  
To apply these queue properties to all other interfaces on the switch, click Copy  
Settings to All Interfaces.  
Mapping CoS/802.1p Priorities to Queues  
The priority of a packet arriving on an interface might be identified by an IEEE  
802.1p priority value in the Ethernet frame header. 802.1p specifies eight priority  
levels (0–7). Use the CoS/802.1p to Queue page to map these priority levels to the  
four CoS queues to steer packets to the appropriate outbound queue. Queue1  
has the lowest priority and queue 4 has the highest priority.  
To map 802.1p priority values to queues:  
STEP 1 Click Quality of Service > CoS/802.1p to Queue in the navigation window.  
STEP 2 Select from the Interface drop-down menus the Port or the LAG to configure.  
STEP 3 For each 802.1p Class of Service, select a queue from the Output Queue list.  
Queue 1 has the lowest priority, and queue 4 has the highest priority.  
STEP 4 Click Apply. Your changes are saved to the Running Configuration.  
STEP 5 To apply these mappings to all other interfaces on the switch, click Copy Settings  
to All Interfaces.  
Cisco Small Business SG200 Series 8-port Smart Switch  
168  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quality of Service  
Mapping CoS/802.1p Priorities to Queues  
11  
NOTE If you click Restore Defaults, the following mappings are applied to the selected  
interface.  
802.1p Priority  
Output Queue  
0
1
2
3
4
5
6
7
1
1
2
3
3
4
4
4
Cisco Small Business SG200 Series 8-port Smart Switch  
169  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quality of Service  
Mapping IP Precedence to Queues  
11  
Mapping IP Precedence to Queues  
802.1p Priority  
Output Queue  
0
1
2
3
4
5
6
7
3
1
2
4
5
6
7
8
The priority of a packet arriving at an interface can be identified by the  
Type of Service (ToS) field in an IP packet header. Eight precedence levels are  
defined (0-7). You can use the IP Precedence to Queue page to map these values  
to the four. CoS queues to steer packets to the appropriate outbound queue.  
Queue1 has the lowest priority and queue 4 has the highest priority.  
NOTE IP Precedence-to-queue mapping is configured per interface. Configure these  
mapping values on the incoming interface.  
To map IP precedence values to queues:  
STEP 1 Click Quality of Service > IP Precedence to Queue in the navigation window.  
STEP 2 Select from the Interface drop-down menus the Port or the LAG to configure.  
STEP 3 For each IP Precedence value, select a queue from the Output Queue list. Queue1  
has the lowest priority, and queue 4 has the highest priority.  
STEP 4 Click Apply. Your changes are saved to the Running Configuration.  
To apply these mappings to all other interfaces on the switch, click Copy Settings  
to All Interfaces.  
Cisco Small Business SG200 Series 8-port Smart Switch  
170  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quality of Service  
Mapping DSCP Values to Queues  
11  
NOTE If you click Restore Defaults, the following mappings are applied to all interfaces.  
IP Precedence  
Output Queue  
0
1
2
3
4
5
6
7
1
1
2
3
3
4
3
3
Mapping DSCP Values to Queues  
The priority of a packet arriving at an interface can be identified by the  
Differentiated Service Code Point (DSCP) value in an IP packet header. The IP  
DSCP field might contain any one of 64 values (0–63). You can use the DSCP to  
Queue page to map these values to the four egress queues. Queue 1 has the  
lowest priority and queue 4 has the highest priority.  
DSCP mapping settings are applied globally to all ports.  
To map DSCP values to queues:  
STEP 1 Click Quality of Service > DSCP to Queue in the navigation window.  
STEP 2 For each Ingress DSCP value, select a queue from the Output Queue list. Queue1  
has the lowest priority, and queue 4 has the highest priority.  
STEP 3 Click Apply. Your changes are saved to the Running Configuration.  
Cisco Small Business SG200 Series 8-port Smart Switch  
171  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quality of Service  
Defining Rate Limit Profiles  
11  
NOTE If you click Restore Defaults, the following mappings are applied to all interfaces.  
DSCP Value  
00-07  
Output Queue  
1
1
2
3
3
4
3
3
08-15  
16-23  
24-31  
32-39  
40-47  
48-55  
56-63  
Defining Rate Limit Profiles  
The rate-limiting feature enables you to set a maximum incoming traffic rate for a  
port. When the data rate exceeds configured rate, the switch drops all further  
traffic from the port. Rate limits are applied per port.  
To apply rate limits, you first use this page to create one or more rate limit profiles.  
Profiles specify the criteria that determines when the rate limit is exceeded. Then,  
you assign rate limit profiles to interfaces (see Applying Rate Limit Profiles to  
To add an entry to the Rate limit Profile Table:  
STEP 1 Click Quality of Service > Rate Limit Profile in the navigation window.  
STEP 2 Click Add.  
STEP 3 Enter the parameters:  
Profile ID—Specify any number from 1 to 64 to identify the profile.  
CIR—Specify the committed information rate, which is the rate at which data  
is transmitted. The rate is averaged over a minimum time increment. The  
range is 64-1048576 Kbps.  
Cisco Small Business SG200 Series 8-port Smart Switch  
172  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quality of Service  
Applying Rate Limit Profiles to Interfaces  
11  
CBS—Specify a committed burst size, which is the guaranteed amount of  
bandwidth for bursty traffic on the port. The range is 4-16384 KB.  
STEP 4 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
Applying Rate Limit Profiles to Interfaces  
If you have created one or more rate limit profiles, you can use this page to assign  
them to interfaces. See Defining Rate Limit Profiles for instructions on creating  
profiles.  
To apply a rate limit profile to an interface.  
STEP 1 Click Quality of Service > Interface Rate Limit in the navigation window.  
STEP 2 Use the Interface Type list to display Ports or LAGs in the Interface Rate Limit  
Table.  
STEP 3 Select the interface to configure and click Edit.  
STEP 4 Add or remove a profile:  
To assign a profile to this interface, click the profile ID in the Available list,  
and then click the right-arrow button to move it to the Selected list. All  
profiles disappear from the Available list, since only one profile can be  
assigned to a port.  
To remove a profile, click the profile ID in the Selected list, and then click the  
left-arrow button to move it to the Available list. All profiles appear in the  
Selected list.  
STEP 5 Click Apply and then click Close. Your changes are saved to the Running  
Configuration.  
Cisco Small Business SG200 Series 8-port Smart Switch  
173  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Quality of Service  
Traf f i c S h a p i n g  
11  
Traffic Shaping  
You can use the Traffic Shaping page to smooth the packet output rate. You can  
configure the maximum output rate for each port and LAG, expressed as a  
percentage of bandwidth. When the traffic rate reaches this limit, excess packets  
are retained in a queue and then are scheduled for later transmission over  
increments of time.  
To configure traffic shaping on a port or LAG:  
STEP 1 Click Quality of Service > Traffic Shaping in the navigation window.  
STEP 2 Use the Interface Type menu to display Ports or LAGs in the Traffic Shaping  
Settings table.  
STEP 3 Select the interface to configure and click Edit.  
STEP 4 For the selected Port or LAG, enter the output rate limit as a percentage of the total  
bandwidth and click Apply.  
STEP 5 Repeat the previous step as needed to assign bandwidth utilization to other ports  
and LAGs.  
STEP 6 When you are finished, click Close. Your changes are saved to the Running  
Configuration.  
Cisco Small Business SG200 Series 8-port Smart Switch  
174  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Cisco and the Cisco Logo are trademarks of Cisco Systems, Inc. and/or its affiliates in the U.S. and other countries. A listing of Cisco's trademarks can be found  
at www.cisco.com/go/trademarks. Third party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply  
a partnership relationship between Cisco and any other company. (1005R)  
Copyright © 2010 Cisco Systems, Inc. All rights reserved.  
78-19562-01  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Black Box Bluetooth Headset 640 User Manual
Black Decker Can Opener KEC600 User Manual
Black Decker Saw 3335 User Manual
Bosch Appliances Computer Keyboard LTC 8557 Series User Manual
Bose Home Theater System solo tv sound system User Manual
BRK electronic Fire Extinguisher BF5 User Manual
Canon All in One Printer 6224B002 User Manual
Canon Digital Camera 2764B004 User Manual
Casio Video Game Keyboard SA 76 User Manual
Chamberlain Safety Gate SW470 User Manual