Chromalox Electric Heater NWHOF 27 User Manual

®
Chromalox  
SERVICE REFERENCE  
Installation  
DIVISION  
SALES  
4
SECTION NWHO  
(Supersedes PE437)  
and  
REFERENCE  
PE437-1  
RENEWAL PARTS IDENTIFICATION  
161-303184-001  
DATE  
APRIL, 1999  
Type NWHO(F)-27 Series Circulation Heater  
(for Regular and Fuel Oil Heating)  
Thermostat  
(When Specified)  
Specifications — Table A  
Regular Oil Heaters  
3 - 1-3/8" K.O.  
Dimensions (In.)  
B
for 1" Conduit  
15-15/16"  
Model  
Volts  
Phase  
kW  
W/In2  
A
C
3" Pipe  
Outlet (Std.)  
NWHO-2780R15  
NWHO-2790R15  
NWHO-27100R15  
NWHO-27120R15  
240 or 480  
240 or 480  
240 or 480  
240 or 480  
3
3
3
3
80  
90  
100  
120  
20  
20  
20  
20  
77-9/16  
81-9/16  
87-9/16  
97-9/16  
52  
56  
62  
72  
48-1/2  
52-1/2  
58-1/2  
68-1/2  
2 Mtg. Lugs Ea  
with Three 3/4" - 10  
x1-1/8" Deep  
Holes on 1-3/4"  
Centers  
A
C
B
Fuel Oil Heaters  
A
NWHO-2750R15  
NWHO-2760R15  
NWHO-2770R15  
240 or 480  
240 or 480  
240 or 480  
3
3
3
50  
60  
70  
12  
12  
12  
77-9/16  
87-9/16  
97-9/16  
52  
62  
72  
48-1/2  
58-1/2  
68-1/2  
A
3" Pipe  
Inlet (Std.)  
11"  
3/4" NPT  
Pipe Plug  
Dimensions and ratings vary according to customer requirements.  
Check engineering drawing for specifications.  
F-Denotes heater is baffled, i.e., NWH0F  
17-1/8"  
GENERAL  
Depending upon the specifications, the NWHO-27 may or may not be  
factory equipped with AR or other Chromalox thermostats. Such ther-  
mostats function to control outlet temperatures and limits internal tem-  
perature under abnormal flow conditions. These controls do not fail-safe.  
Thermocouples are also available as an option.  
WARNING: This heater is not intended for use in haz-  
ardous atmospheres where flammable vapors, gases,  
liquids or other combustible atmospheres are present  
as defined in the National Electrical Code. Failure to  
comply can result in explosion or fire.  
CAUTION: Users should install adequate back-up con-  
trols and safety devices with their electric heating  
equipment. Where the consequences of failure may be  
severe, back-up controls are essential. Although the  
safety of installation is the responsibility of the user,  
Chromalox will be glad to make equipment recom-  
mendations.  
Hazardous area terminal enclosures are available, consult your  
local Chromalox representative for details.  
The NWHO-27 series is a general-purpose oil circulation heater  
intended for use indoors.  
The 27 or 36 steel sheathed tubular elements are welded to a remov-  
able steel flange and centered in a 10 inch diameter steel heating chamber.  
INSTALLATION  
ing assembly on either of the lugs.  
WARNING: Hazard of Shock. Disconnect all power  
before installing heater.  
5. DANGER: Hazard of Fire. Provide minimum of 6” spacing  
from a chamber and related piping to nearest combustible materi-  
al. Avoid operation of heater near combustible fluids or in com-  
bustible vapor or gas laden atmosphere.  
1. Vertical mounting (axis of chamber vertical as in sketch above) is  
preferred. (Terminal housing at top of heater) (Figure A)  
2. When mounting heater horizontally, inlet and outlet MUST be up.  
In any other position, heater cannot be purged of air and elements  
may be seriously damaged. (Figure B)  
3. This series of circulation heaters are provided with mounting lugs  
to support the heater chamber. Refer to sketch above for location  
of these mounting lugs.  
6. Provide adequate space at terminal end to permit withdrawal of the  
heater from chamber should servicing be required.  
7. If two or more heaters are needed to provide the needed heating  
capacity, arrange them for series oil flow.  
8. DANGER: Possible Explosion. A pressure relief valve  
should be provided by customer at outlet of vessel. There should  
be no other valving between vessel and valve.  
4. Mount heaters to permit unrestrained expansion of chamber due to  
temperature. This can be accomplished by using a slotted mount-  
Correct  
Incorrect  
Correct  
Incorrect  
Figure A — Vertical Mounting  
Figure B — Horizontal Mounting  
© 2010 Chromalox, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Belkin Network Router F5D5231 4 User Manual
BMW Automobile Parts 733i User Manual
Briggs Stratton Portable Generator 030210 2 User Manual
Brother Electronic Accessory PE DESIGN 7 User Manual
Cadco Convection Oven XAL 135 User Manual
Cadco Microwave Oven CAPO 3303S User Manual
Cannon Electric Pressure Cooker C60GC User Manual
Canon Camera Lens EF100 400mm f 45 56L IS USM User Manual
Canon Photo Printer IP3500 User Manual
Casio Watch ma 1203 EB User Manual