Chief Manufacturing Indoor Furnishings PLP Series User Manual

I N S T A LL A T I O N IN S T R U C T IO N S  
PLP Series Wall Mount  
The PLP Series wall mount accommodates large flat  
screens weighing up to 200 lbs (90.72kg). The teardrop  
holes in the mount allow for quick connect/disconnect of  
the screen, thus simplifying installation and maintenance  
processes.  
The top and bottom mounting brackets are adaptable to  
supporting framework with wood studs that are 16” on  
center or 24”on center.  
The mount has integrated lateral shift, allowing for four  
different mounting options. For dual wood studs 16” on  
center, the lateral shift is + 4.5 inches. For dual wood  
studs 24” on center, the lateral shift is + 0.5 inches.  
The display can be pulled and tilted by hand into any  
position in the zero-to-15 degree tilt range and remain  
stationary.  
The bottom of the mount pulls forward 4” from the wall  
and locks into place for installation of cable connections.  
The mount also uses Chief’s exclusive Q-Latch™  
mounting system, which offers quick connect/disconnect  
display mounting. The display is secured to the mount  
with a latching flag. For additional security, you can lock  
the latching flag in place by adding a padlock.  
PLP Series  
CHIEF MANUFACTURING INC.  
8805-000183 Rev F  
© 2008 Chief Manufacturing  
03/08  
1-800-582-6480 952-894-6280 FAX 952-894-6918  
8401 EAGLE CREEK PARKWAY, STE. 700  
SAVAGE, MINNESOTA 55378 USA  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
PLP Series  
DIMENSIONAL  
DRAWING  
26.00  
TOP MOUNTING BUTTO N ON  
PSB-XXXX DRAWING G O ES HERE  
24.00  
16.00  
16.00  
1.83  
16.00  
.69  
C
1.87  
15.51  
18.38  
17.00  
13.19  
4.24  
FAC E TILTS  
15 DO WN  
7
UP (FOR SERVIC E)  
NOTE: C USTOM INTERFAC E BRAC KET  
NOT SHO WN. THE C USTOM INTERFAC E  
BRAC KET NEEDED FO R YOUR DISPLAY  
WILL ADD BETWEEN 1/2" AND 2" IN DEPTH  
AND MAY AFFEC T LO C ATIO N OF DISPLAY  
ON THE MO UNT.  
SEE PSB-XXXX DRAWING ALSO .  
5/16" x 1" SLOT  
5/16" x 6" SLO T  
5/16" x 1" SLO T  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
PLP Series  
PARTS LIST  
Prior to assembly, unpack the carton completely. Verify  
contents listed in Table 1 and Figure 1.  
CONTENTS  
DIMENSIONAL DRAWING ..................................... 3  
TOOLS REQUIRED FOR INSTALLATION.............. 4  
PARTS LIST .............................................................. 4  
PLP INSTALLATION................................................ 5  
Select Mounting Location........................................ 5  
Mount the PLP ........................................................ 6  
ATTACH PSB TO THE DISPLAY............................. 7  
INSTALL THE DISPLAY.......................................... 7  
REMOVE THE DISPLAY.......................................... 7  
TILT ADJUSTMENT................................................. 8  
CABLE CONNECTION............................................. 8  
Read installation instructions completely. If you are  
missing any of the listed parts, contact Customer Service  
at: 1-800/582-6480.  
Table 1. Parts List  
REF  
10  
DESCRIPTION  
PLP Series Wall Mount  
QTY  
1
4
4
20  
BOLT, Lag, 5/16” x 2-½”  
WASHER, 5/16”  
30  
TOOLS REQUIRED FOR  
INSTALLATION  
20 - 4 Lag Bolts  
x
Drill and drill bit set  
x
Socket wrench set  
NOTE: Other tools may be required depending on your  
method of installation.  
30 - 4 Washers  
10  
Figure 1. PLP Parts  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
PLP Series  
PLP INSTALLATION  
Perform the following procedures to mount the PLP.  
Hang the mount on  
the wall temporarily  
using a nail in the  
center hole. Level the  
mount before drilling  
pilot holes.  
Select Mounting Location  
To select the mounting location, do the following:  
WARNING: It is the responsibility of the installer to  
verify that the wall to which the mount is  
anchored will safely support the  
combined load of all attached  
components and equipment.  
Figure 2. Use Triangular Hole to Hang the Mount  
1. Determine the exact mounting location to install the  
wall mount prior to installation, keeping in mind the  
screen size.  
Wood Studs  
16”  
NOTE: Mount the PLP on dual wall studs or some other  
equivalent supporting framework that is vertical  
or horizontal.  
Wall  
Pilot Holes  
2. Using a stud sensor, locate the two wood studs where  
you will mount the PLP as follows:  
x
Refer to Figure 3 for wood studs that are  
16” apart on center.  
Pilot Holes  
OR  
x
Refer to Figure 4 for wood studs that are  
24” apart on center.  
3. Using a nail as a temporary hook, hang the mount on  
the wall using the triangular hole located in the center  
of the mount (see Figure 2).  
Figure 3. Wood Studs 16”Apart on Center  
4. Use a pencil to mark the mounting holes where the  
four pilot holes will be drilled into the center of the  
wood stud. Make sure the mounting holes are square  
and straight. Remove the mount from the wall,  
placing it on the floor or a table.  
Wood Studs  
24”  
5. Drill pilot holes using a 7/32” drill.  
Wall  
Pilot Holes  
Pilot Holes  
Figure 4. Wood Studs 24”Apart on Center  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
PLP Series  
PLP INSTALLATION (Cont’d)  
Mount the PLP  
To mount the PLP, do the following:  
Option A  
1. Holding the PLP against the wall, select the pair of  
mounting holes that best suits your situation (see  
Figures 5, 6, and 7).  
NOTE: The mounting holes are slotted to allow for a  
small degree of lateral movement. The mount can  
be centered, or shifted to the left of center, or  
right of center depending on stud location.  
2. Depending on your situation, install the lag bolts and  
washers into the pilot holes previously drilled, as  
described below.  
Figure 5. Mounting Holes – 16” Apart on Center  
(Option A)  
Option B  
x
x
x
Option A. Install four 5/16” x 2-½” lag bolts  
(20) and four 5/16” washers (30) (two top and  
two bottom) into the mounting holes, centering  
the PLP on dual wood studs 16” apart on center  
as shown in Figure 5.  
Option C  
OR  
Option B. Install four 5/16” x 2-½” lag bolts (20)  
and four 5/16” washers (30) (two top and two  
bottom) into the mounting holes that are right of  
center on dual wood studs 16” apart as shown in  
Figure 6.  
OR  
Option C. Install four 5/16” x 2-½” lag bolts  
(20) and four 5/16” washers (30) (two top and  
two bottom) into the mounting holes that are left  
of center on dual wood studs 16” apart dual  
wood studs 16” apart on center as shown in  
Figure 6.  
Figure 6. Mounting Holes – 16" Apart on Center  
(Options B and C)  
OR  
Option D  
x
Option D. Install four 5/16” x 2-½” lag bolts  
(20) and four 5/16” washers (30) (two top and  
two bottom) into the mounting holes, centering  
the PLP on dual wood studs 24” apart on center  
as shown in Figure 7.  
3. Tighten all lag bolts.  
Figure 7. Mounting Holes – 24" Apart On Center  
(Option D)  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
PLP Series  
ATTACH PSB TO THE DISPLAY  
To attach the PSB to the display, do the following:  
Display  
x
To help your identify the correct PSB that matches  
the model number of your display, refer to the cross-  
reference chart at www.chiefmfg.com.  
x
To download the corresponding PSB installation  
instructions, refer to www.chiefmfg.com.  
OR  
x
Contact Customer Service at 952-582-6480 if you  
have any questions about how to select the PSB that  
matches the model number of your display.  
INSTALL THE DISPLAY  
PLP  
To install the display, do the following:  
NOTE: Verify that all power/audio/video cables are  
disconnected from the display and the latching  
flag is lowered in the down position before  
attempting to mount the display.  
PSB  
Figure 8. Install the Display  
1. With the aid of another person, lift the display up to  
the mount on the wall, aligning mounting buttons  
with the teardrop slots on the mount, and lower the  
display firmly into place (Figure 8).  
Lock  
Unlock  
2. Raise the latching flag to secure the display (see  
Figure 9). If the flag does not fully engage, check to  
ensure the mounting buttons are fully seated in the  
slots.  
Teardrop Slot  
NOTE: A padlock may be installed through the hole in  
Latching  
Flag  
the latching flag for additional security.  
REMOVE THE DISPLAY  
To remove the display from the mount, do the following:  
1. Disconnect all power/audio/video cables.  
Figure 9. Raise Latching Flag to Lock  
2. Lower the latching flag to unlock the display (refer to  
Figure 9).  
3. With the aid of another person, lift the display up and  
out of the teardrop slots in the mount to remove the  
display.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
PLP Series  
15
°  
TILT ADJUSTMENT  
0
°  
To tilt the display 0° to 15° down, do the following:  
1. Manually tilt the display 0° to 15° down into the  
desired position.  
2. If desired, tighten the nut (see Figure 10) to increase  
the amount of tension needed to hold the mount in  
the position set in Step 1.  
1. Adjust pitch  
2. If necessary, tighten  
nut slightly to  
increase tension.  
NOTE:Tighten the nuts only to adjust the amount of  
tension needed to manually tilt and hold the  
mount in place. Do not over-tighten the nuts.  
Over-tightening the nuts may cause excessive  
wear and may damage your mount.  
3. Repeat Steps 1 and 2 until the desired tension is  
obtained.  
Figure 10. Tilt Display Down  
1. Tilt display down  
CABLE CONNECTION  
To install or remove cables, do the following:  
(see Fig. 10)  
2. Pull bottom out  
(See Fig. 11)  
3. Lower support bar.  
4. Perform service.  
5. Return display to  
desired position.  
1. Manually tilt display down slightly (see Figure 10),  
and then pull bottom of display out (see Figure 11).  
2. Lower center support bar to keep the display tilted up  
(see Figure 12).  
3. Perform service. For example: Connect or disconnect  
the power/audio/video cables.  
NOTE:The service position is not recommended as a  
final display position.  
4. Raise the center support bar and reposition the  
display to desired position (if necessary, refer to  
“TILT ADJUSTMENT” procedure) after service is  
completed.  
0°  
8°  
Figure 11. Tilt Display Up (for service only)  
WARNING: Watch for pinch points. Do not put your  
fingers between moveable parts.  
Tilt the display  
0° to 8° to connect  
or disconnect cables.  
Center  
support bar  
Figure 12. Cable Connection  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  

Beko Washer WMB71242PTLMA User Manual
Black Box Network Card LMC200A 2PS DC User Manual
Bowflex Cordless Drill 0513 21 User Manual
Brother Fax Machine MFC 8220 User Manual
Califone Headphones 1218AV 03 User Manual
Canon All in One Printer 3480i User Manual
Canon Digital Camera 1D Mark III User Manual
Canon Microphone DM 100 User Manual
Carrier DVD Player 50TCA04 A07 User Manual
Cisco Systems Conference Phone OL 7372 01 User Manual