Installation Instructions
PDC Series
LEGEND
Tighten Fastener
Pencil Mark
Apretar elemento de fijación
Befestigungsteil festziehen
Apertar fixador
Marcar con lápiz
Stiftmarkierung
Marcar com lápis
Segno a matita
Potloodmerkteken
Marquage au crayon
Serrare il fissaggio
Bevestiging vastdraaien
Serrez les fixations
Loosen Fastener
Drill Hole
Aflojar elemento de fijación
Befestigungsteil lösen
Desapertar fixador
Perforar
Bohrloch
Fazer furo
Praticare un foro
Gat boren
Allentare il fissaggio
Bevestiging losdraaien
Desserrez les fixations
Percez un trou
Phillips Screwdriver
Adjust
Destornillador Phillips
Ajustar
Kreuzschlitzschraubendreher
Chave de fendas Phillips
Cacciavite a stella
Einstellen
Ajustar
Regolare
Afstellen
Ajuster
Kruiskopschroevendraaier
Tournevis à pointe cruciforme
Open-Ended Wrench
Llave de boca
Remove
Quitar
Gabelschlüssel
Chave de bocas
Chiave a punte aperte
Steeksleutel
Entfernen
Remover
Rimuovere
Verwijderen
Retirez
Clé à fourche
By Hand
Optional
Opcional
Optional
Opcional
Opzionale
Optie
A mano
Von Hand
Com a mão
A mano
Met de hand
À la main
En option
Hex-Head Wrench
Security Wrench
Llave de cabeza hexagonal
Sechskantschlüssel
Chave de cabeça sextavada
Chiave esagonale
Llave de seguridad
Sicherheitsschlüssel
Chave de segurança
Chiave di sicurezza
Veiligheidssleutel
Clé de sécurité
Zeskantsleutel
Clé à tête hexagonale
3
Download from Www.Somanuals.com. All Manuals Search And Download.
PDC Series
Installation Instructions
TOOLS REQUIRED FOR INSTALLATION
9/16" (14.3 mm)
PARTS
A (1)
C (1)
5/32"
B (1)
1/8"
D (2)
D3 (1)
10-24 x 3/8"
D2 (1)
10-24
D4 (1)
3/16"
D6 (1)
4-40
D5 (1)
4-40 x 2-1/2"
D1 (1)
D8 (1)
5/16-18 x 2-3/4"
D7 (1)
5/16-18
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
PDC Series
4. Attach interface brackets to back of displays following
INSTALLATION
instructions included with the interface brackets.
Preparing for Installation
Installing Displays on PDC
1. Attach click-lock flag kits (D) to PDC following instructions
included with the kits.
WARNING: EXCEEDING MAXIMUM WEIGHT CAPACITY
CAN LEAD TO SERIOUS PERSONAL INJURY OR
DAMAGE TO EQUIPMENT! It is the installers responsibility
to ensure the total amount of weight placed on the mount
does not exceed 400 lbs (181.44 kg) [200 lbs (90.72 kg) each
faceplate].
WARNING: FAILURE TO PROVIDE ADEQUATE
STRUCTURAL STRENGTH FOR THIS COMPONENT CAN
RESULT IN SERIOUS PERSONAL INJURY OR DAMAGE
TO EQUIPMENT! It is the installer’s responsibility to make
sure the structure to which this component is attached can
support five times the combined weight of all equipment.
Reinforce the structure as required before installing the
component.
WARNING: DISPLAY MAY WEIGH IN EXCESS OF
40 LBS (18.14 KG)! Always use two people and proper lifting
techniques when installing or positioning display.
2. Determine if NPT pipe is 1-1/2" or 2".
•
•
If NPT pipe is 1-1/2", proceed to Step 3.
If NPT pipe is 2", loosen set screw and
remove the 1-1/2" to 2" pipe coupler, then
proceed to Step 3.(See Figure 1)
Pipe
Coupler
Set
Screw
(A)
Display
Figure 3
1. While supporting each side of display, align four mounting
buttons on display or interface bracket with four slots on
PDC. (See Figure 3)
2. Lower each display into place listening for audible "click" to
ensure recessed area of mounting buttons are properly
seated in lower area of mounting holes.(See Figure 4)
Figure 1
3. Thread the PDC (A) onto the NPT pipe extension and
tighten set screw. (See Figure 2)
NPT
Pipe
Set
Screw
1
(A)
Figure 2
5
Download from Www.Somanuals.com. All Manuals Search And Download.
PDC Series
Installation Instructions
Remove bolt
or padlock
if used
2
3
May remove
pin and nut and
move to lower holes
1
Pin in
"Closed"
position -
move to
"Open"
2
position to
remove
display
A padlock or bolt
may be placed
through latch holes
5
Figure 4
WARNING: IMPROPER INSTALLATION CAN LEAD TO
DISPLAY FALLING CAUSING SERIOUS PERSONAL
INJURY OR DAMAGE TO EQUIPMENT! Ensure mounting
buttons are completely engaged in mounting holes.
Pin in
"Open"
position -
move to
"Closed"
position
NOTE: Holes are provided in the faceplate for use with a
padlock or similar locking device, if desired. In addition,
the pin and nut may be removed from the upper holes
and moved to the lower holes for use as a more
permanent locking device. (See Figure 4)
after display
is removed.
3. Connect and secure power, audio and video cables.
Removing Displays from PDC
Figure 5
1. Disconnect all power/audio/video cables.
2. Remove bolt or padlock from faceplate (if used).
(See Figure 5)
WARNING: EACH DISPLAY MAY WEIGH IN EXCESS OF
40 LBS EACH! Always use two people and proper lifting
techniques when installing or positioning displays on PDC.
NOTE: The pin may have been used as a more permanent
locking device. If so, remove nut and pin and move
from the lower holes to the upper holes.
4. Carefully lift displays from PDC.
3. Pull back on flag on upper mounting hole and press pin
down down into "Open" position. (See Figure 5)
5. Lift up on pin and place flag back against faceplate to return
it to "Closed" position. (See Figure 5)
Adjustments
Roll Adjustment
1. Loosen two Nylock nuts inside the PDC. (See Figure 6)
2. Using the slotted holes, adjust the roll, or horizontal
movement.
3. Tighten two Nylock nuts.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
PDC Series
4
5
x 2
x 2
x 2
x 2
1
2
6
3
(Display and faceplate
removed for clarity)
Figure 6
Pitch Adjustment
4. Loosen two screws on side of PDC. (See Figure 6)
5. Adjust to desired pitch, or vertical movement.
6. Tighten the screws on side of PDC.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
PDC Series
Installation Instructions
USA/International
Europe
A
P
F
A
P
F
8401 Eagle Creek Parkway, Savage, MN 55378
800.582.6480 / 952.894.6280
877.894.6918 / 952.894.6918
Fellenoord 130 5611 ZB EINDHOVEN, The Netherlands
+31 (0)40 2668620
+31 (0)40 2668615
Asia Pacific
A
Room 24F, Block D, Lily YinDu International Building
LuoGang, BuJi Town, Shenzhen, CHINA.
8805-000115 Rev.D
¤2008 Chief Manufacturing
01/08
P
F
+86-755-8996 9226
+86-755-8996 9217
Download from Www.Somanuals.com. All Manuals Search And Download.
|