Chicago Electric Landscape Lighting 90599 User Manual

45 WATT SOLAR KIT  
Model 90599  
InSTALLATIOn And SeRvIce InSTRucTIOnS  
Read this material before using this product.  
Failure to do so can result in serious injury.  
SAve ThIS MAnuAL.  
©
®
Copyright 2003, 2009 by Harbor Freight Tools . All rights reserved. No portion of this manual or any  
artwork contained herein may be reproduced in any shape or form without the express written consent of  
Harbor Freight Tools. Diagrams within this manual may not be drawn proportionally. Due to continuing  
improvements, actual product may differ slightly from the product described herein. Tools required for  
assembly and service may not be included.  
For technical questions or replacement parts, please call 1-800-444-3353.  
Revised Manual 11k  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. do not wire multiple panels in  
series. If you need to connect two  
or more solar panels together, this  
work must be done by a qualified  
electrician unless they are connected  
through a regulator.  
10. Panel must be connected using  
UL listed outdoor rated wire of the  
correct thickness (gauge) for the  
amperage rating and length (see  
warning number 9 also). Follow the  
guidelines in the chart below:  
current  
in Amps  
Maximum Length  
4. This solar panel kit is not designed  
for tie-in to a grid. Only a licensed  
electrician and a licensed building  
contractor can safely design and  
implement a grid tie-in system. Any  
grid tie-in system must meet all  
applicable building and electrical  
codes, and must meet standards  
established by the area power  
5'  
10'  
15'  
18  
20'  
25'  
0-5  
6-7  
8
10  
11-12  
15  
18  
20  
22-24  
30  
40  
18  
16  
18  
16  
16  
18  
16  
14  
14  
12  
18  
16  
16  
14  
12  
10  
10  
12  
company. Improper grid tie-in can  
result in electrocution, fire, and other  
serious personal injury and property  
damage. An incorrectly installed grid  
tie-in system can cause feedback  
voltage, resulting in electrocution of  
electrical utility workers.  
14  
12  
10  
6
8
4
2
50  
14  
12  
10  
8
100  
150  
200  
10  
8
6
4
Minimum Wire Gauge  
5. do not stand on or otherwise apply  
pressure to panel.  
11. Install an appropriate charge  
controller/regulator to regulate output  
and prevent damage. Do not attach  
panel to battery or power grid without  
proper regulator, inverter, and/or  
charge controller.  
6. handle solar panel with care,  
edges may be sharp.  
7. do not focus light on panel.  
8. Install components with enough  
space to allow proper cooling.  
12. Install and use according to  
applicable National Electrical Code  
(NEC) standards.  
9. This product may occasionally  
produce more current and/or  
voltage than its rated output.  
Increase output ratings by 25%  
when determining component  
required voltage and amperage  
ratings. Refer to Section 690-8 of  
the National Electrical Code for an  
additional multiplying factor of 125  
percent (80 percent derating) which  
may apply.  
13. This panel is not rated for use as  
fire-resistant roofing. If installing on  
a roof, install only over a fire resistant  
roof covering rated for the application.  
14. Verify that installation surface has no  
hidden utility lines before drilling or  
driving screws.  
15. Install only according to these  
instructions. Improper installation  
can create hazards.  
SKU 90599  
For technical questions, please call 1-800-444-3353.  
Page 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16. Wear ANSI-approved safety goggles  
and heavy-duty work gloves during  
installation. Do not wear jewelry or  
metal watches when working near  
solar panels, wiring or batteries.  
Service precautions  
1. Before service, maintenance, or  
cleaning:  
a. dry solar panels and outdoor  
wiring thoroughly while wearing  
electrically insulated gloves.  
17. Handle panel with care. Glass  
may break or a sharp edge may be  
exposed during movement.  
b. cover all solar panels with an  
opaque cover, such as a blanket.  
18. Keep installation area clean and well  
lit.  
c. disconnect all solar panels.  
d. disconnect all batteries.  
19. Install out of reach of children.  
2. do not service during rain, fog, or  
any other wet/humid weather.  
20. Keep bystanders out of the area  
during installation.  
3. do not stand on or otherwise apply  
pressure to panel.  
21. Do not install when tired or when  
under the influence of drugs or  
medication.  
4. Do not allow children to play with  
or near this item or electrical  
components.  
22. Use in 12 VDC systems only.  
5. Inspect at least monthly; do not use  
if damaged, parts are loose, water is  
found inside the housing, electrical  
insulation is cracked or damaged, or  
connections are loose.  
Battery precautions  
23. Wear splash-resistant AnSI-  
approved safety goggles and  
electrically insulated gloves while  
working near batteries.  
6. Maintain product labels and  
nameplates. These carry important  
safety information. If unreadable or  
missing, contact Harbor Freight Tools  
for a replacement.  
24. use an appropriate charge  
controller whenever connected to  
battery.  
25. Charge, store, and maintain batteries  
according to supplier’s instructions.  
7. WARNING: Handling the cord on  
this product will expose you to lead,  
a chemical known to the State of  
California to cause cancer, and  
birth defects or other reproductive  
harm. Wash hands after handling.  
(California Health & Safety Code §  
25249.5, et seq.)  
SAve TheSe  
InSTRucTIOnS.  
SKU 90599  
For technical questions, please call 1-800-444-3353.  
Page 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
to children to prevent electric shock.  
Build a childproof enclosure if  
needed.  
SpecIFIcATIOnS  
14.5 V~ / 15 W  
(working)  
Rated Output  
3. Install the charge controller/regulator  
and batteries in a weatherproof  
Open Circuit Voltage  
Adapter Outlets  
23.5 OCV  
3, 6, 9 and 12 VDC  
enclosure with proper ventilation.  
note: Output will decrease as the panel  
gets hotter than room temperature  
(~70° F). Angle, solar intensity,  
cloud cover and other factors will  
effect output  
Mounting  
1. Angle the face of the panel toward  
1
true south according to the chart that  
follows:  
Latitude Solar panel Angle  
0-4°  
10°  
5-20°  
21-45°  
46-64°  
Latitude + 5°  
Latitude + 10°  
Latitude + 15°  
unpAcKInG  
When unpacking, make sure that the  
item is intact and undamaged. If any parts  
are missing or broken, please call Harbor  
Freight Tools at 1-800-444-3353 as soon  
as possible.  
65° or more 80°  
ASSeMBLY  
6a  
InSTALLATIOn  
Read the enTIRe IMpORTAnT  
SAFeTY InFORMATIOn  
section at the beginning of this  
manual including all text under  
subheadings therein before set  
up or use of this product.  
Slot 3  
6b  
1. Slide the Left and Right Triangle  
Frame (6a and 6b) into slot 1 and  
slot 3 on both ends of the Top Link  
Bar (6d) and Bottom Link Bar (6C)  
(to form the frame assembly). See  
above.  
note: For additional information regarding  
the parts listed in the following pages,  
refer to the Assembly Diagram near  
the end of this manual.  
Location  
1. Locate the panel where it will receive  
full, unobstructed sunlight, especially  
during midday. Nearby trees or tall  
plants will drop debris, requiring the  
panel to be cleaned more frequently.  
2. The installation location for the  
panels, charge controller/regulator,  
and batteries must be inaccessible  
1
Angle towards true north if installed in  
southern hemisphere.  
SKU 90599  
For technical questions, please call 1-800-444-3353.  
Page 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
provide enough ventilation to allow  
the unit to vent and cool properly.  
Slot 2  
Slot 1  
6c  
4. Secure the Frame Assembly (6a-  
6d) to its mounting location using  
hardware (not supplied) through the  
four holes on the bottom of the Left  
and Right Triangle Frames (6a &  
6b).  
6d  
5. Carefully place each Solar panel (1)  
on the front of the Frame Assembly  
(6a-6d) so that the bottom of each  
panel fits into the slot on the bottom  
of the Frame Assembly (6a-6d).  
2. Push the Top Link Bar (6d) down to  
slot 2 (to lock the frame assembly).  
See above.  
3. Determine where you want to position  
the Frame Assembly (6a-6d) making  
sure it is facing south (for maximum  
sun exposure) with no obstructions  
in front of it. The Regulator (2) must  
be in a dry, well ventilated location  
nearby. If necessary, build a small  
structure that guarantees the unit will  
stay dry during rain or snow, and,  
6. Lock the two eye hooks on the back-  
center frame into the two protruding  
bolts on the Top Link Bar (6d).  
cAuTIOn: If the unit is to be mounted  
on a rooftop, be especially careful  
when climbing ladders and walking  
on sloped roofs. Additional hardware  
may have to be purchased if  
SKU 90599  
For technical questions, please call 1-800-444-3353.  
Page 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
permanently mounting the Solar  
panels on a rooftop.  
3. Secure all connections using  
terminals, or solder all wire splices to  
ensure good connections.  
hook-up diagram  
4. Weatherproof all connections.  
Regulator (2)  
Solar panels (1)  
OpeRATIOn  
lead  
wires  
note: Performance of the Solar Panels  
will vary dependent on site location,  
angle of the panels in relation to the  
arc of the sun, and available sunlight.  
7. Connect the two ring connectors at  
the end of the lead wires coming  
from the Solar panels (1) to the  
Solar Terminals on the Regulator  
(2). See FIGuRe 1. Be sure to  
connect by matching polarities on  
the wires and the Regulator (2).  
Black (-) is negative and red (+) is  
positive. Then, connect the wire  
leads so that all of the Solar panels  
(1) are connected to each other and  
the Regulator (2) (again, making  
sure you are hooking up to the right  
polarity on the Regulator). See  
hook-up diagram, above.  
Recharging a Battery  
1. To recharge a 12 volt battery (not  
included), while paying attention  
to the proper polarity (black (-) is  
negative and red (+) is positive),  
connect the two ring terminals on  
the Battery connector (3) to the  
Battery Terminals on the back of  
the Regulator (2). See FIGuRe  
1. Then, connect the black clamp to  
the black or negative (-) terminal on  
the battery (not included). Finally,  
connect the red clamp to the red or  
positive (+) terminal on the battery.  
Avoid accidental contact of the red  
and black battery clamps to each  
other.  
Wiring  
note: Only a licensed electrician and  
a licensed building contractor can  
safely design and implement a grid  
tie-in system. Any grid tie-in system  
must meet all applicable building  
and electrical codes, and must meet  
standards established by the area  
power company.  
note: Do not change the order explained  
in number 1 above or electric shock  
resulting in serious injury or death  
may occur.  
2. Turn on the Regulator. See the On/  
Off switch in FIGuRe 1 on page 6.  
1. Run wires from the panels, through  
weatherproof grommets and into  
the enclosure where the charge  
controller/regulator is located. Use  
wires of the proper size and rating.  
3. Never leave the battery (not included)  
unattended while charging. When  
the battery (not included) is fully  
charged, the reading on the voltage  
display will show “13” or above.  
Note: the voltage display will have to  
be turned on in order to monitor the  
2. Connect to charge controller/regulator  
according to controller/regulator’s  
instructions.  
SKU 90599  
For technical questions, please call 1-800-444-3353.  
Page 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
batter voltage. (It is recommended to  
leave the voltage display off when not  
monitoring the battery voltage since it  
consumes energy.) Twelve (12) Volt  
batteries should charge to 13 Volts  
for a full charge. If the intent is to  
stop charging the battery, disconnect  
the solar panels from the charge  
regulator. Note: The charge regulator  
provides “over charge” protection. If  
the battery voltage is higher than 14.5  
V, the regulator will shut off charge  
from solar panel.  
using the 12 volt Lights and  
Accessories.  
note: The Charge Regulator must be in  
“ON” position at all times.  
1. If the 12 volt Lights (4) aren’t  
already attached to the sockets on  
the end of each Light Wire (7), gently  
snap them in.  
2. Plug the other end of the Light  
Wire (7) into any one of the 12 Volt  
DC outlets on the Regulator (2) as  
shown in FIGuRe 2.  
4. The Regulator (2) provides the  
following protection while charging:  
a. Over-discharge protection: When  
the electricity level of the battery  
(not included) goes too low (below  
11 volts) the Regulator (2) will  
automatically shut off the power  
output to prevent damage to the  
battery (not included). If this occurs,  
stop using the battery (not included)  
and charge it until the Voltage  
display shows 13 volts.  
Figure 2  
Led  
Display  
Switch  
b. Overcharge protection: If the  
electricity level on the battery (not  
included) goes too high (above  
14.5 volts) the Regulator (2) will  
automatically shut off power input to  
prevent damage to the battery (not  
included).  
12 Volt DC  
Socket  
Controller  
Power  
Switch  
Voltage  
Display  
c. Overload protection: If the output  
current exceeds 4 amps the fuse  
(See FIGuRe 1) will blow to prevent  
damage to the controller in the  
Regulator (2). If this occurs, have a  
qualified service technician replace  
the fuse.  
Light Sockets  
3. To turn off the lights, unplug the Light  
Wire (7) from the 12 Volt DC outlet  
on the Regulator (2). You may plug  
in the other 12 volt Light (4) to either  
12 Volt DC outlet.  
note: The On/Off switch of the charge  
regulator must be in the “On”  
position to activate the three  
protection functions mentioned  
above.  
note: This system can also be used to  
power other small 3 Volt DC, 6 Volt  
DC, and 9 Volt DC small appliances.  
SKU 90599  
For technical questions, please call 1-800-444-3353.  
Page 8  
REV 10k  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Plug the appropriate plug on the  
Multi purpose Adapter (5) into the  
appliance. The adapter has 3 Volt  
DC, 5 Volt DC, 6 Volt DC, 9 Volt DC,  
and 12 Volt DC plugs.  
TO pRevenT SeRIOuS  
InjuRY FROM eLecTRIc  
ShOcK OR cuTS:  
do not use damaged solar  
panel. If wiring insulation  
is damaged or weathered,  
glass is cracked, or housing  
is opened, have the problem  
corrected before further use.  
5. Insert the plug on the other end of the  
wire attached to the Multi purpose  
Adapter (5) into the appropriate DC  
Outlet on the Regulator (2). For  
your reference, FIGuRe 2 shows the note: It is normal to see up to 20%  
adapter wire plugged into the 3 Volt  
DC outlet.  
degradation in amorphous silicon  
solar panel performance within the  
first 6 months before the amorphous  
coating stabilizes.  
6. Operate your appliance.  
7. When finished, unplug the Multi  
purpose Adapter (5) wire plug from  
the Regulator (2) and then unplug  
the Multi purpose Adapter (5) from  
the appliance.  
cleaning  
Clean and inspect the solar panel  
system MOnThLY, or more  
frequently to maintain peak efficiency:  
1. Wear electrically insulated gloves  
and AnSI-approved safety goggles.  
Dry solar panels and outdoor wiring  
thoroughly.  
SeRvIcInG  
Procedures not specifically  
explained in this manual  
must be performed only by a  
qualified technician.  
2. cover all solar panels with an  
opaque cover, such as a blanket.  
TO pRevenT  
SeRIOuS InjuRY  
3. disconnect all solar panels and  
batteries.  
FROM eLecTRIc ShOcK:  
Before service, maintenance,  
or cleaning:  
4. Clean solar panels one at a time with  
mild, non-abrasive cleanser and soft  
cloth and paper towels. Do not clean  
with brushes or abrasive cleaners.  
a. dry solar panels and outdoor  
wiring thoroughly while  
wearing electrically insulated  
gloves.  
5. Inspect the general condition of the  
solar panel system (panels, batteries,  
controllers, and mounting). Check  
for loose hardware, wiring insulation  
damage or weathering, cracked  
glass, open housing, cracked or  
broken parts, loose or corroded  
contacts, and any other condition that  
may affect its safe operation.  
b. cover all solar panels with  
an opaque cover, such as a  
blanket.  
c. disconnect all solar panels.  
d. disconnect all batteries.  
SKU 90599  
For technical questions, please call 1-800-444-3353.  
Page 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Inspect and maintain batteries  
according to supplier’s instructions.  
Adjustment  
To Increase Efficiency:  
7. In the Winter, increase the panel’s  
angle by 10°.  
8. In the Summer, decrease the angle  
by up to 10°.  
9. In the Spring and Fall, keep the  
panel at the angle recommended on  
the chart on page 9.  
SKU 90599  
For technical questions, please call 1-800-444-3353.  
Page 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
pLeASe ReAd The FOLLOWInG cAReFuLLY  
THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY  
DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR  
DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT  
HE OR SHE IS qUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS  
qUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/  
OR DISTRIBUTOR ExPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD  
BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE  
BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE  
ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER  
INSTALLATION OF REPLACEMENT PARTS THERETO.  
pARTS LIST And ASSeMBLY dIAGRAM  
part  
description  
Solar Panel  
Q’ty  
part  
6a  
6b  
6c  
6d  
7
description  
Left Triangle Frame  
Right Triangle Frame  
Bottom Link Bar  
Top Link Bar  
Q’ty  
1
2
3
4
5
3
1
1
2
1
1
1
1
1
2
Regulator  
Battery Connector  
12 Volt Light  
Multi-purpose Adapter  
Light Wire  
7
2
5
4
Record product’s Serial number here:  
note: If product has no serial number, record month and year of purchase instead.  
note: Some parts are listed and shown for illustration purposes only, and are not  
available individually as replacement parts.  
REV 11k  
SKU 90599  
For technical questions, please call 1-800-444-3353.  
Page 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Belkin Network Card F5D8010 User Manual
Black Decker Battery Charger 91 005 User Manual
Black Decker Juicer LCJ82 User Manual
Bose Headphones QuietComfort 3 User Manual
Briggs Stratton Plumbing Product AC0201 User Manual
Bryant Furnace 394GAD User Manual
Calibre UK Home Theater System VANTAGE HD User Manual
CDA Double Oven 11Z6 User Manual
Chamberlain Home Security System 916GA User Manual
Christie Digital Systems Projector 38 VIV301 01 User Manual