1. BEFORE YOU BEGIN  
What Is Included  
Ø
Ø
Ø
Ø
Ø
1 x Hurricane™ 1100  
1 x FC-M Wired Manual Remote  
Power Cord  
1 x Warranty Card  
1 x Quick Reference Guide  
Unpacking Instructions  
Immediately upon receiving a fixture, carefully unpack the carton, check the contents to  
ensure that all parts are present, and have been received in good condition. Notify the  
shipper immediately and retain packing material for inspection if any parts appear  
damaged from shipping or the carton itself shows signs of mishandling. Save the carton  
and all packing materials. In the event that a fixture must be returned to the factory, it is  
important that the fixture be returned in the original factory box and packing.  
Claims  
The carrier is responsible for any damage incurred during shipping to this product or any  
part that shipped with it. Therefore, if the received merchandise appears to have damages  
caused during shipping, the customer must submit the damage report and any related  
claims with the carrier, not CHAUVET®. The customer must submit the report upon  
reception of the damaged merchandise. Failure to do so in a timely manner may invalidate  
the customer’s claim with the carrier.  
For other issues such as missing components or parts, damage not related to shipping, or  
concealed damage, the customer must make claims to CHAUVET® within seven (7) days  
of receiving the merchandise.  
Product at a Glance  
Use on Dimmer  
Auto Programs  
x
x
x
x
x
x
x
P
x
x
Outdoor Use  
Sound-Activated  
DMX  
Auto-ranging Power Supply  
Replaceable Fuse  
User-Serviceable  
Duty Cycle  
Master/Slave  
Hurricane™ 1100 User Manual  
3
Rev. 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Safety Instructions  
Please read the following notes carefully because they include important safety  
information about the installation, usage, and maintenance of this product.  
·
·
Please keep this User Guide for future consultation. If you sell the unit to another  
user, be sure that they also receive this instruction booklet.  
Always make sure that you are connecting to the proper voltage, and that the line  
voltage you are connecting to is not higher than that stated on the decal or rear panel  
of the fixture.  
·
·
This product is intended for indoor use only! (If applicable)  
To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure  
there are no flammable materials close to the unit while operating.  
·
·
·
·
·
The unit must be installed in a location with adequate ventilation, at least 20in (50cm)  
from adjacent surfaces. Be sure that no ventilation slots are blocked.  
Always disconnect from power source before servicing or replacing lamp or fuse and  
be sure to replace with same lamp source.  
Secure fixture to fastening device using a safety chain. Never carry the fixture solely  
by its head. Use its carrying handles.  
Maximum ambient temperature (Ta) is 104°F (40°C). Do not operate fixture at  
temperatures higher than this.  
In the event of a serious operating problem, stop using the unit immediately. Never try  
to repair the unit by yourself. Repairs carried out by unskilled people can lead to  
damage or malfunction. Please contact the nearest authorized technical assistance  
center. Always use the same type spare parts.  
·
·
·
·
Never connect the device to a dimmer pack.  
Make sure the power cord is never crimped or damaged.  
Never disconnect the power cord by pulling or tugging on the cord.  
Avoid direct eye exposure to the light source while it is on.  
There are no user serviceable parts inside the unit. Do not open the housing or  
attempt any repairs yourself. In the unlikely event your unit may require service,  
please contact CHAUVET at: 954-929-1115.  
FCQ (Fog Cleaner Quart) was specifically developed by Chauvet to clean your  
Hurricane™ 1100. Make sure you use FCQ regularly to increase the life of your  
fogger.  
Hurricane™ 1100 User Manual  
4
Rev. 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2. INTRODUCTION  
Product Overview  
Hanging  
bracket  
Fluid  
container  
Safety cable  
eye bolt  
Tilt  
Adjustment  
knob  
Heater  
Nozzle  
Manual Fog  
button  
Low Fluid  
indicator  
Fluid level  
indicator  
Manual  
Controller  
Wireless  
Controller  
Power input  
(hardwired)  
Fuse holder  
Hurricane™ 1100 User Manual  
5
Rev. 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Product Dimensions  
242 mm / 9.5 in  
258 mm / 10.2 in  
Hurricane™ 1100 User Manual  
6
Rev. 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. SETUP  
AC Power  
To determine the power requirements for a particular fixture, see the label affixed to the  
back plate of the fixture or refer to the fixture’s specifications chart. A fixture’s listed  
current rating is its average current draw under normal conditions. All fixtures must be  
powered directly off a switched circuit and cannot be run off a rheostat (variable resistor)  
or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to 100%  
switch. Before applying power to a fixture, check that the source voltage matches the  
fixture’s requirement. Check the fixture or device carefully to make sure that if a voltage  
selection switch exists that it is set to the correct line voltage you will use.  
Fuse Replacement  
Unplug the IEC power cable before replacing the fuse! Always replace with  
same type of fuse.  
This product has a replaceable fuse. In the event that the fuse needs to be replaced,  
follow the instructions provided below.  
1. Using a flat head screwdriver, remove the fuseholder from the IEC housing.  
2. Remove the bad fuse from the fuseholder.  
3. Insert the new fuse into the  
fuseholder.  
4. Install the fuseholder in the IEC  
housing.  
The fuse is located  
inside this  
compartment.  
Remove using a flat  
head screwdriver.  
Hurricane™ 1100 User Manual  
7
Rev. 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Mounting  
Orientation  
This fixture should only be mounted/used on a flat surface. This fixture may not be tilted.  
Rigging  
It is important never to obstruct the vents’ pathways. Mount the fixture using, a suitable “C”  
or “O” type clamp.  
·
When selecting installation location, take into consideration the fluid  
reservoir access and routine maintenance.  
·
·
Safety cables must always be used, utilizing the provided safety eye bolt.  
Never mount in places where the fixture will be exposed to rain, high  
humidity, extreme temperature changes or restricted ventilation.  
Hanging Clamp  
Note!  
Angled Down  
Angled Up  
Clamp is sold separately.  
Hurricane™ 1100 User Manual  
8
Rev. 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
4. OPERATING INSTRUCTIONS  
This mode will allow you to control the fogger manually, set the fog machine to run continuously, or  
to set the fog machine to run off bursts with adjustable interval and duration settings.  
Manual Remote Operation (FC-M) (Standard)  
1. Plug in the fog machine to power.  
2. Plug in the M remote to the Manual Controller socket on the rear of the fog machine.  
3. Press the single button located on the remote to trigger the fog output.  
The button is momentary, which means that the fog machine will only output while the  
button is pressed. Once the button is released, the fog will stop outputting.  
Timer Remote Operation (FC-T) (Optional)  
1. Plug in the fog machine to power.  
2. Plug in the timer remote to the Manual Controller socket on the rear of the fog machine.  
3. Press the TIMER ON/OFF button on the timer remote. The LED above the button should  
light, indicating activation of function.  
4. You may now set the INTERVAL & DURATION adjustment knobs to the desired position.  
The INTERVAL is the time between bursts of fog.  
The DURATION is the time that the fog machine will run during the burst.  
Duration  
Adjustment  
Interval  
Adjustment  
Timer LED  
Indicator  
Manual  
Momentary  
LED  
Manual/Power  
LED  
Manual control  
Momentary  
Timer Latching  
Button  
Continuous  
Latching Button  
Hurricane™ 1100 User Manual  
9
Rev. 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Wireless Controller (FC-W) (Optional)  
This mode will allow you to control the fogger using the optional wireless controller. This consists of  
the transmitter and the receiver. You may control up to 4 independent fog machines, or many more  
if you run them simultaneously. See the below instructions on setting up your fogger to operate with  
the FC-W.  
1. Plug the wires receiver into the fog machine 5-pin port labeled “Wireless Controller”.  
2. There are 4 buttons on the wireless remote transmitter which act as triggers. Each button  
can be assigned to a different fog machine. You may only choose 1 dipswitch on each  
receiver. See the below configuration for setting the receivers to operate with the  
transmitter remote.  
Mode  
Dipswitches  
CH1  
1 = On, 2-4 = Off  
CH2  
CH3  
CH4  
2 = On, 1,3,4 = Off  
3 = On, 1,2,4 = Off  
4 = On, 1,2,3 = Off  
3. Press the fog button, and the fog machine will output fog momentarily for as long as you  
hold down the button.  
LED indicator  
(heating)  
LED indicator  
(ready)  
Dipswitches  
Wireless  
Transmitter  
Wireless  
Receiver  
Hurricane™ 1100 User Manual  
10  
Rev. 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
General Troubleshooting  
Symptom  
Solution(s)  
No Power  
Check mains power.  
Check external fuse.  
Check internal fuse.  
Check fluid level.  
Check remote.  
No fog output  
If using wireless, check batteries.  
If using wireless, check dipswitches on receiver.  
Possible electrical short. Contact Chauvet or a Chauvet  
Dealer/distributor for further instruction.  
Run a cleaning solution through the fog machine.  
Check that the fog machine is plugged into the correct voltage.  
Check the external fuse.  
Breaker/Fuse keeps blowing  
Low fog output  
Fog machine is not heating up  
Check the internal fuse.  
Possible bad part. Contact Chauvet or a Chauvet Dealer/distributor  
for further instruction.  
Remote does not work  
Make sure connector is firmly connected to device.  
Try using another controller. Possible bad controller.  
Check the internal fuse.  
Check the external fuse.  
Fluid indicator states no fog, but  
the container if full.  
Try resetting the fog machine by turning the power off, and then on  
again.  
Possible bad part. Contact Chauvet or a Chauvet Dealer/distributor  
for further instruction.  
If you still have a problem after trying the above solutions, please contact CHAUVET Technical  
Support at the location listed below.  
Contact Information  
World Headquarters  
United Kingdom & Ireland  
CHAUVET® Europe Ltd.  
General Information  
CHAUVET®  
General Information  
Address: 5200 NW 108th Avenue  
Sunrise, FL 33351  
Address:  
Unit 1C  
Brookhill Road  
Voice:  
Fax:  
(954) 577-4455  
(954) 929-5560  
Pinxton, Nottingham, UK  
NG16 6NT  
Toll free: (800) 762-1084  
Technical Support  
Voice:  
Fax:  
+44 (0)1773 511115  
+44 (0)1773 511110  
Voice:  
Fax:  
(954) 577-4455 (Press 4)  
(954) 756-8015  
World Wide Web  
World Wide Web  
Hurricane™ 1100 User Manual  
11  
Rev. 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5. TECHNICAL INFORMATION  
General Maintenance  
Do not allow the haze machine to become contaminated. After every 40 hours of  
continuous operation, use Chauvet® Fog Cleaner Quart (or a solution of 80% distilled  
water and 20% distilled vinegar) through the system to prevent the accumulation of  
particulate matter in the heating element is recommended.  
The recommended cleaning regimen is as follows:  
1. Empty all haze liquid from the machine.  
2. Add cleaning solution to tank.  
3. Plug unit in and allow it to warm up.  
4. Run the unit in a well-ventilated area until the tank is almost empty. Do not  
allow the pump to run dry.  
5. Cleaning is now complete. Refill with haze liquid. Run the machine briefly to  
clear any cleaning solution from the pump and heater.  
Fog Cleaner Quart (FCQ) was specifically developed by Chauvet® to clean your  
Hurricane™ 1100. Make sure you use FCQ regularly to increase the life of your  
product.  
Before storing this product, FCQ through the system as described in the cleaning  
method above. This will help to avoid any particles condensing inside the pump or  
heater.  
Storage  
Test-run your Hurricane™ 1100 on a monthly basis to achieve the best performance.  
Hurricane™ 1100 User Manual  
12  
Rev. 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Return Procedure  
Returned merchandise must be sent prepaid and in the original packing, call tags will not  
be issued. Package must be clearly labeled with a Return Merchandise Authorization  
Number (RMA #). Products returned without a RMA # will be refused. Call CHAUVET and  
request a RMA # prior to shipping the fixture. Be prepared to provide the model number,  
serial number and a brief description of the cause for the return. Be sure to properly pack  
fixture, any shipping damage resulting from inadequate packaging is the customer’s  
responsibility. CHAUVET reserves the right to use its own discretion to repair or replace  
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe  
method to use.  
If you are given an RMA #, please include the following information on a piece of  
paper inside the box:  
1. Your name  
2. Your address  
3. Your phone number  
4. RMA #  
5. A brief description of the symptoms  
Hurricane™ 1100 User Manual  
13  
Rev. 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
TECHNICAL SPECIFICATIONS  
WEIGHT & DIMENSIONS  
Length...................................................................................................10.2 in (258 mm)  
Width ..................................................................................................... 9.5 in (242 mm)  
Height .................................................................................................... 8.9 in (225 mm)  
Weight .....................................................................................................8.4 lbs (3.8 kg)  
POWER  
AC Power.......................................................................120 V 60 Hz AC or 230 V 50 Hz  
Fuse (115V) .....................................................................................................8 A 250 V  
Power Consumption.............................................................774 W (5.9 A) max at 120 V  
Inrush Power........................................................................................... (6.5A) at 120 V  
Power Factor..............................................................................................0.99 at 120 V  
Fuse (230V) .....................................................................................................5 A 250 V  
Power Consumption.............................................................750 W (3.3 A) max at 230 V  
Inrush Power.........................................................................................(3.14 A) at 230 V  
Power Factor..............................................................................................0.99 at 230 V  
THERMAL  
Maximum ambient temperature.................................................................. 104°F (40°C)  
CONTROL & PROGRAMMING  
Data input .................................................................5-pin & ground DIN5 female socket  
Data pin configurationpin1(LED), pin2(control), pin3(+5V), pin4(ground), pin5(none), ground(none)  
ORDERING INFORMATION  
Hurricane™ 1100..................................................................................................F1100  
Wired manual remote (included)  
FC-M  
Wired timer remote (optional) ..................................................................................FC-T  
Wireless manual remote (optional) .........................................................................FC-W  
SPARE PARTS ORDERING INFORMATION  
Master PCB ..........................................................................................P170-F1MSPCB  
Heater P120-HT7  
Pump...................................................................................................... P200-F1PUMP  
Fluid container ............................................................................................P170-F1FLC  
Fluid sensor  
P170-F1FLOS  
Thermal switch..........................................................................................P170-THEF11  
Bracket knob......................................................................................... P111-F1BKNOB  
Fuse holder  
P170-FUSEHOL  
Manual fog button ....................................................................................P111-F1FOGB  
WARRANTY INFORMATION  
Warranty......................................................................................1-year limited warranty  
Hurricane™ 1100 User Manual  
14  
Rev. 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

Belkin Switch F1U126 KIT User Manual
Beyerdynamic Microphone MTS 67 User Manual
Black Decker Power Screwdriver 5147205 00 User Manual
Bosch Appliances Dishwasher SHP65TL5UC User Manual
Bosch Power Tools Cordless Sander PS50 User Manual
Breville Fryer BDF600XL User Manual
Broan Air Conditioner 170F User Manual
Casio Watch 1182 User Manual
Celestron Telescope CR 150 HD User Manual
Chief Manufacturing Indoor Furnishings MFC Series User Manual