Chauvet Indoor Furnishings ST 3000LED User Manual

LED Techno Strobe  
ST-3000LED  
User Manual  
CHAUVET, 3000 N 29th Ct, Hollywood, FL 33020 U.S.A  
(800) 762-1084 (954) 929-1115  
FAX (954) 929-5560  
2009-12-10/14:04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Before You Begin  
UNPACKING INSTRUCTIONS  
Immediately upon receiving a product, carefully unpack the carton, check the contents to ensure that  
all parts are present, and have been received in good condition. Notify the shipper immediately and  
retain packing material for inspection if any parts appear damaged from shipping or the carton itself  
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture  
must be returned to the factory, it is important that the fixture be returned in the original factory box  
and packing.  
Note:  
If you should require sending any items back to CHAUVET, call CHAUVET for  
a (RMA) Return Merchandise Authorization number. The factory will not allow  
any shipments without an RMA.  
Your shipment includes the following:  
1 x LED Techno Strobe™  
1 x Power cable  
1 x Warranty Card  
1 x Users Manual  
CONTACT US  
World Wide  
General Information  
Chauvet Lighting  
3000 North 29th Court  
Hollywood, FL 33020  
voice: 954.929.1115  
fax:  
954.929.5560  
toll free: 800.762.1084  
Technical Support  
World Wide Web  
Chauvet Lighting  
3000 North 29th Court  
Hollywood, FL 33020  
voice: 954.929.1115 (Press 4)  
fax:  
954.929.5560 (Attention: Service)  
ST-3000LED User Manual  
3
2009-12-10/14:04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Before You Begin  
IMPORTANT SAFETY INFORMATION  
This product is designed for professional use. It is not intended for use in a household environment.  
This product presents risks of lethal or severe injury due to fire and heat, electric shock, ultraviolet  
radiation, lamp explosion, and injury from falls. Read this manual before installing or powering the  
fixture, follow the safety precautions listed below and observe all warnings in this manual and on the  
fixture. If you have any questions about how to operate the fixture safely, please contact CHAUVET.  
Protection against Electric Shock  
Always disconnect from AC power source before servicing or replacing lamp or fuse and be sure  
to replace with same lamp source.  
All Class I fixtures must be connected to circuits with a suitable Earth Ground.  
To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no  
flammable materials close to the unit while operating.  
Do not operate the fixture if covers are open or if any internal component is missing or damaged:  
an unshielded discharge lamp emits dangerous UV radiation that can cause burns and eye  
damage.  
Make sure power cord is never crimped or damaged.  
Never disconnect power cord by pulling or tugging on the cord.  
Protection against Fire & Burns  
This product is designed to be used with very specific lamp(s). Use of any other type of lamp not  
stated in this manual may create a fire hazard due to possible risk of lamp explosion. Using the  
wrong type of lamp in this product VOIDS the warranty.  
Always make sure that you are connecting to the proper voltage and that the line voltage you are  
connecting to is not higher than that stated on decal or rear panel of the fixture.  
The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent  
surfaces. Be sure that no ventilation slots are blocked.  
Maintain a minimum distance of 1 meter (3.28 feet) from combustible materials.  
Allow this product to cool for a minimum of 15 minutes before opening, handling or removing the  
lamp in this product.  
Maximum ambient temperature is Ta: 40°. Do not operate fixture at temperatures higher than  
this.  
Protection against exposure to (UV) Ultraviolet Radiation  
Avoid direct eye exposure to lamp while it is on.  
Do not operate the fixture if covers are open or if any internal component is missing or damaged.  
Protection against Injury to persons  
Secure fixture to fastening device using a safety chain.  
A hot lamp is an explosion hazard. Do not open fixture for a minimum of 15 minutes after  
switching off. Wear eye and hand protection when re-lamping.  
Fixture surface may reach temperatures of up to 160° C (320° F). Handle fixture after it cools.  
In the event of serious operating problem, stop using the unit immediately. Never try to repair the  
unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction.  
Please contact the nearest authorized technical assistance center. Always use the same type  
spare parts.  
Caution!  
There are no user serviceable parts inside the unit. Do not open the housing or  
attempt any repairs yourself. In the unlikely event your unit may require service,  
please contact CHAUVET.  
ST-3000LED User Manual  
4
2009-12-10/14:04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Introduction  
FEATURES  
3-channel DMX-512 LED white strobe light  
Blackout/static/dimmer/strobe  
Adjustable flash rate, dimmer and static in stand-alone via DIP switches  
Built-in automated programs via master/slave or DMX  
Built-in sound activated programs via master/slave or DMX  
ADDITIONAL FEATURES  
Linkable with LED Shadow™, LED Shadow™ 2, LED Techno Strobe™, LED Techno Strobe™ RGB, LEDsplash™ 200B  
and LEDsplash™ 2 in stand alone  
Additional power output: max 50 units  
Includes brackets for wall and truss mounting  
DMX CHANNEL SUMMARY  
1
2
3
DMX Channel  
(Columns)  
Strobe  
Slow ~ Fast  
Dimmer  
000~039  
040~239  
Intensity  
100% ~ 0%  
Preset Programs  
(1 ~ 6)  
Speed  
Slow ~ Fast  
Sound Mode  
240~255 No Function  
CONTROL MODES & OPTIONS  
(Rows)  
For a detailed view of DMX values turn to the Appendix section in this manual. Control mode parameters are  
set by DMX values in Channel # 1.  
ST-3000LED User Manual  
5
2009-12-10/14:04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction  
PRODUCT OVERVIEW  
Hanging Yoke  
Audio Sensitivity  
Rotary knob  
DIP-switches  
DMX Input  
DMX Output  
Power Link Out  
DMX Addressing  
Red LED: Power Indicator  
Blue LED: Signal Indicator  
IEC Plug for AC Input  
& Fuse Compartment  
Flush Mounting Bracket  
LED Front Panel  
ST-3000LED User Manual  
6
2009-12-10/14:04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Setup  
AC POWER  
Warning!  
Verify that the power requirement label on your unit matches the line voltage  
applied. All fixtures must be connected to circuits with a suitable Earth Ground.  
To determine the power requirements for a particular fixture, see the label affixed to the back plate  
of the fixture or refer to the fixture’s specifications chart.  
A fixture’s listed current rating is its average current draw under normal conditions.  
All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat  
(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0%  
to 100% switch.  
Before applying power to a fixture, check that the source voltage matches the fixture’s  
requirement.  
All fixtures must be connected to circuits with a suitable Earth Ground.  
Power Cable Configuration  
CABLE  
BROWN  
Pin  
Live  
International  
Screw Color  
Yellow or Brass  
Silver  
L
N
BLUE  
Neutral  
Earth  
YELLOW/GREEN  
EG (Ground)  
Green  
MOUNTING  
Orientation  
This fixture can be mounted on a truss using a clamp in any position or against a flat surface using  
the brackets provided.  
Rigging  
The fixture includes a mounting yoke to which 1 rigging clamp can be bolted  
and (2) Flush Mount Brackets for flush mounting to flat surfaces. You must  
supply your own clamp and make sure the clamp is capable of supporting the  
weight of this fixture. You can order C-clamps from any CHAUVET dealer or  
distributor.  
Hanging Clamp  
1.  
2.  
3.  
Block access below the work area and use suitable and stable  
platform when installing or servicing fixture.  
Align the clamp screw with the center hole on the yoke and  
tighten.  
Flush Mounting Bracket  
Verify the structure can hold 10 times the weight of all to-be  
installed fixtures.  
4.  
5.  
Adjust the angle on the yoke arm as necessary.  
Always use a safety cable or chain as a secondary source of  
attachment. The safety cable must hold 10 times the weight of the  
fixture. If safety cable attachment point is provided that is  
permanently affixed to the surface or body of the fixture, use that  
instead of looping through a hanging yoke/arm.  
Flush Mounting  
1.  
2.  
3.  
Draw a screw hole template on a large piece of vellum or transparent paper for best alignment.  
Place paper against the mounting surface and drill holes or mark the surface for drilling.  
Hang Panel.  
ST-3000LED User Manual  
7
2009-12-10/14:04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setup  
FIXTURE LINKING  
You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller  
or to run synchronized shows on two or more fixtures set to a master/slave operating mode. The  
combined number of channels required by all the fixtures on a serial data link determines the number  
of fixtures the data link can support.  
The ST-3000LED fixtures use 3 channels of DMX control.  
Important: Fixtures on a serial data link must be daisy chained in one single line. To  
comply with the EIA-485 standard no more than 32 devices should be  
connected on one data link. Connecting more than 32 fixtures on one serial  
data link without the use of a DMX optically isolated splitter may result in  
deterioration of the digital DMX signal.  
Maximum recommended serial data link distance: 500 meters (1640 ft.)  
Maximum recommended number of fixtures on a serial data link: 32 fixtures  
Data Cabling  
To link fixtures together you must obtain data cables. You can purchase CHAUVET certified DMX  
cables directly from a dealer/distributor or construct your own cable. If you choose to create your own  
cable please use data-grade cables that can carry a high quality signal and are less prone to  
electromagnetic interference.  
DMX Data Cable  
Use a Belden© 9841 or equivalent cable which meets the specifications for EIA RS-485 applications.  
Standard microphone cables cannot transmit DMX data reliably over long distances. The cable will  
have the following characteristics:  
2-conductor twisted pair plus a shield  
Maximum capacitance between conductors 30 pF/ft.  
Maximum capacitance between conductor and shield 55 pF/ft.  
Maximum resistance of 20/ 1000 ft.  
Nominal impedance 100 - 140Ω  
Cable Connectors  
Cabling must have a male XLR connector on one end and a female XLR connector on the other end.  
Resistance 120  
1
3
DMX connector configuration  
ohm ¼ w between  
pin 2 (DMX -) and  
pin 3 (DMX +) of  
the last fixture.  
2
COMMON  
DMX +  
1
1
3
INPUT  
3
OUTPUT  
Termination reduces signal errors and  
to avoid signal transmission problems  
and interference, it is always  
2
2
DMX -  
advisable to connect a DMX signal  
CAUTION Do not allow contact between the common and the fixture’s chassis ground.  
Grounding the common can cause a ground loop and your fixture to perform  
erratically. Test cables with OHM meter to verify correct polarity and to make  
sure the pins are not grounded or shorted to the shield or each other.  
ST-3000LED User Manual  
8
2009-12-10/14:04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setup  
3-Pin to 5-Pin Conversion Chart  
Note!  
If you use a controller with a 5 pin DMX output connector, you will need to use  
a 5 pin to 3 pin adapter.  
The chart below details a proper cable conversion:  
3 PIN TO 5 PIN CONVERSION CHART  
Conductor  
3 Pin Female (output)  
Pin 1  
5 Pin Male (Input)  
Pin 1  
Ground/Shield  
Data ( - )signal  
Data ( + ) signal  
Not Used  
Pin 2  
Pin 3  
Pin 2  
Pin 3  
Pin 4  
Pin 5  
Not Used  
SETTING UP A DMX SERIAL DATA LINK  
Universal DMX Controller  
1. Connect the (male) 3 pin connector side of  
the DMX cable to the output (female) 3 pin  
connector of the controller.  
2. Connect the end of the cable coming from  
the controller which will have a (female) 3  
pin connector to the input connector of the  
next fixture consisting of a (male) 3 pin  
connector.  
This drawing provides a  
general illustration of the  
DMX Input/Output panel  
of a lighting fixture.  
3. Then, proceed to connect from the output  
as stated above to the input of the following  
fixture and so on.  
CHAUVET Certified DMX Data Cables  
Continue the link  
STANDALONE/MASTER-SLAVE FIXTURE LINKING  
1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector  
of the first fixture.  
2. Connect the end of the cable coming from the first fixture which will have a (female) 3 pin  
connector to the input connector of the next fixture consisting of a (male) 3 pin connector. Then,  
proceed to connect from the output as stated above to the input of the following fixture and so on.  
Fixtures displayed are for illustration purpose only!  
Often, the setup for Master-Slave  
and Standalone operation  
requires that the first fixture in the  
chain be initialized for this  
purpose via DIP switches.  
Secondarily the fixtures that  
follow may also require a slave  
setting. Please consult the  
“Operating Instructions” section  
in this manual for complete  
instructions for this type of setup  
and configuration.  
ST-3000LED User Manual  
9
2009-12-10/14:04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Operating Instructions  
The ST-3000LED is a DMX-512 controllable, flash LED panel made up of highly efficient and super  
bright white LEDs. The ST-3000LED can operate in Stand-Alone, Master/Slave and via DMX-512  
control utilizing 3 channels.  
STANDALONE MODE  
The ST-3000LED can be operated without a DMX controller in a  
standalone mode. It  
Sound  
Auto  
can be operated as a single fixture or together with several other ST-3000LED fixtures in what is  
1
2
3
4
5
6
7
8
9
10  
ON  
called a “Master/Slave” configuration.  
Single-Fixture Mode  
The ST-3000LED can be set to operate independently of other fixtures or a DMX controller in either a  
sound-active or automatic mode. A serial data-link is not necessary for this mode of operation and it  
is recommended that no connection to other fixtures be made at all.  
1. Simply choose from any one of 10 built-in “DIP switch Optionsfrom the table below.  
Master-Slave Mode  
A master-slave mode setup consists of more than one fixture connected in a serial data link without  
the use of a controller. In a master-slave operation the slave fixtures will synchronize and will behave  
either identically or in a planned chase pattern to the master unit which must be the first in the serial  
daisy chain. A Master-Slave ST-3000LED system can consist of an unlimited range of fixtures or at  
least the number stated to conform to EIA-485 standards.  
Setup  
1. The ST-3000LED sets up automatically for Master-Slave, no DIP-switch settings are required  
other than for selecting DIP-switch Options.  
2. Connect the end of the cable coming from the first fixture which will have a (female) 3 pin  
connector to the DMX IN input connector of the Slave fixture consisting of a (male) 3 pin  
connector. Continue the loop from DMX OUT to DMX IN.  
Dipswitch Options  
Functions  
Dipswitches ( ON )  
Notes & Description  
Sound Active  
None  
Music: Sound Activated, Rotary knob sets sound sensitivity  
1
2
Flash Speed 1  
Flash Speed 2  
3
Flash Speed 3  
4
Flash Speed 4  
Flash  
5
Flash Speed 5  
6
Flash Speed 6  
7
Flash Speed 7  
8
Flash Speed 8  
Full On  
9
All LEDs full on  
Preset Program  
10  
Preset Programs run in Automatic speed  
ST-3000LED User Manual  
10  
2009-12-10/14:04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating Instructions  
DMX CONTROL MODE  
The ST-3000LED can be operated from a DMX controller. This control mode environment gives the  
user the greatest flexibility when it comes to customizing or creating a show by enabling the control of  
each individual trait of the fixture and each fixture independently.  
Configuring for DMX control  
1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector  
of the controller.  
2. Connect the end of the cable coming from the controller which will have a (female) 3 pin connector  
to the input connector of the next fixture consisting of a (male) 3 pin connector.  
3. Then, proceed to connect from the DMX output as stated above to the DMX input of the following  
fixture and so on.  
4. If you need help setting the DMX address read the section titled “Setting the DMX address” in this  
Chapter.  
Setting the DMX address  
Each fixture requires a "start address" from 1 to 511. A fixture requiring one or more channels for  
control begins to read the data on the channel indicated by the start address. For example, a fixture  
that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100, would  
read data from channels: 100, 101, 102, 103, 104, 105 and 106. Choose start addresses so that the  
channels used do not overlap and notate the start address selected for future reference. If this is  
your first time, read the DMX Primer in the Appendix Section.  
DAISY CHAIN (SERIAL DATA LINK)  
Use certified DMX XLR cable  
DMX Output  
DMX Input  
DMX:001  
DMX:004  
DMX:007  
2
3
4
5
6
7
8
9
10  
1
2
3
4
5
6
7
8
9
10  
1
2
3
4
5
6
7
8
9
10  
1
Visit the section titled; Binary & DMX DIP Switch Addressing on page 13 & Binary Addressing Quick  
Reference Chart on page 14 to quickly determine the binary DIP-switch settings for addressing.  
ST-3000LED User Manual  
11  
2009-12-10/14:04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Appendix  
DMX PRIMER  
There are 512 channels in a DMX-512 connection. Channels may be assigned in any manner. A  
fixture capable of receiving DMX-512 will require one or a number of sequential channels. The user  
must assign a starting address on the fixture that indicates the first channel reserved in the controller.  
There are many different types of DMX controllable fixtures and they all may vary in the total number  
of channels required. Choosing a start address should be planned in advance. Channels should  
never overlap. If they do, this will result in erratic operation of the fixtures whose starting address is  
set incorrectly. You can however, control multiple fixtures of the same type using the same starting  
address as long as the intended result is that of unison movement or operation. In other words, the  
fixtures will be slaved together and all respond exactly the same.  
DMX fixtures are designed to receive data through a serial Daisy Chain. A Daisy Chain connection is  
where the DATA OUT of one fixture connects to the DATA IN of the next fixture. The order in which  
the fixtures are connected is not important and has no effect on how a controller communicates to  
each fixture. Use an order that provides for the easiest and most direct cabling. Connect fixtures  
using shielded two conductor twisted pair cable with three pin XLR male to female connectors. The  
shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data positive (S+).  
RETURNS PROCEDURE  
Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued.  
Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products  
returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the  
fixture. Be prepared to provide the model number, serial number and a brief description of the cause  
for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate  
packaging is the customer’s responsibility. CHAUVET reserves the right to use its own discretion to  
repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe  
method to use.  
CLAIMS  
Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be  
reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and  
submit claims with the shipper in the event that a fixture is damaged due to shipping. Any other claim  
for items such as missing component/part, damage not related to shipping, and concealed damage,  
must be made within seven (7) days of receiving merchandise.  
MAINTENANCE  
To maintain optimum performance and minimize wear, fixtures should be cleaned frequently. Usage  
and environment are contributing factors in determining frequency. As a general rule, fixtures should  
be cleaned at least twice a month. Dust build up reduces light output performance and can cause  
overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off  
fixture before conducting maintenance.  
Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust  
collected on external vents and internal components. Clean all glass when the fixture is cold with a  
ST-3000LED User Manual  
12  
2009-12-10/14:04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix  
mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply  
solution to the cloth or tissue and drag dirt and grime to the outside of the lens. Gently polish optical  
surfaces until they are free of haze and lint. Do not to touch the lamp glass when cleaning fixture. Oil  
and dirt can cause damage and premature aging of the lamp. In the event that the lamp is touched or  
becomes dirty, clean the lamps with an alcohol wipe.  
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to  
optimize light output. Cleaning frequency depends on the environment in which the fixture operates:  
damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s  
optics. Clean with soft cloth using normal glass cleaning fluid. - Always dry the parts carefully. - Clean  
the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.  
BINARY & DMX DIP SWITCH ADDRESSING  
Each DIP-switch has an associated value. Adding the value of each switch in the ON position will  
provide the final address. Determining which switches to toggle ON given a specific desired address  
or value can be accomplished in the following manner. By subtracting the largest switch value  
possible from the selected start address which does not cause a negative number.  
Alternatively, using the “Binary Addressing Quick Reference Chart” in the Appendix section of this  
manual, you can go directly to DIP switch settings associated with all 512 values available.  
EXAMPLE ADDRESS  
Address 10  
Pin # 4 = 8  
Pin # 2 = 2  
ON  
2
3
4
5
6
7
8
9 10  
1
Total  
= 10  
Address 24  
Pin # 5 = 16  
Pin # 4 = 8  
ON  
2
3
4
5
6
7
8
9 10  
1
Total  
= 24  
Resolving address  
using simple math.  
233 (128) = 105, Turn ON DIP # 8  
105 (64) = 41, Turn ON DIP # 7  
41 (32) = 9, Turn ON DIP # 6  
9 (8) = 1, Turn ON DIP # 4  
DIP SWITCH  
(DMX VALUE)  
1
2
3
1
2
4
Address 233  
1 (1) = 0, Turn ON DIP # 1  
4
8
5
6
7
8
9
10  
16  
32  
64  
128  
256  
You will most likely use the first available  
number which maybe number 1. This  
number was selected for tutorial  
purposes.  
ST-3000LED User Manual  
13  
2009-12-10/14:04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix  
BINARY ADDRESSING QUICK REFERENCE CHART  
DMX & Binary Address Quick Reference Chart  
DIP switch Position  
DMX DIP SWITCH SET #9  
0
0
0
0
0
0
0
1
0
0
1
0
0
0
1
1
0
1
0
0
0
1
0
1
0
1
1
0
0
1
1
1
1
0
0
0
1
0
0
1
1
0
1
0
1
0
1
1
1
1
0
0
1
1
0
1
1
1
1
0
1
1
1
1
0=OFF  
1=ON  
#8  
#7  
#6  
X=OFF or ON  
#1 #2 #3 #4 #5  
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
32 64  
33 65  
34 66  
35 67  
96  
97  
98  
99  
128  
129  
130  
131  
132  
133  
134  
135  
136  
137  
138  
139  
140  
141  
142  
143  
144  
145  
146  
147  
148  
149  
150  
151  
152  
153  
154  
155  
156  
157  
158  
159  
160  
161  
162  
163  
164  
165  
166  
167  
168  
169  
170  
171  
172  
173  
174  
175  
176  
177  
178  
179  
180  
181  
182  
183  
184  
185  
186  
187  
188  
189  
190  
191  
192  
193  
194  
195  
196  
197  
198  
199  
200  
201  
202  
203  
204  
205  
206  
207  
208  
209  
210  
211  
212  
213  
214  
215  
216  
217  
218  
219  
220  
221  
222  
223  
224  
225  
226  
227  
228  
229  
230  
231  
232  
233  
234  
235  
236  
237  
238  
239  
240  
241  
242  
243  
244  
245  
246  
247  
248  
249  
250  
251  
252  
253  
254  
255  
256  
257  
258  
259  
260  
261  
262  
263  
264  
265  
266  
267  
268  
269  
270  
271  
272  
273  
274  
275  
276  
277  
278  
279  
280  
281  
282  
283  
284  
285  
286  
287  
288  
289  
290  
291  
292  
293  
294  
295  
296  
297  
298  
299  
300  
301  
302  
303  
304  
305  
306  
307  
308  
309  
310  
311  
312  
313  
314  
315  
316  
317  
318  
319  
320  
321  
322  
323  
324  
325  
326  
327  
328  
329  
330  
331  
332  
333  
334  
335  
336  
337  
338  
339  
340  
341  
342  
343  
344  
345  
346  
347  
348  
349  
350  
351  
352  
353  
354  
355  
356  
357  
358  
359  
360  
361  
362  
363  
364  
365  
366  
367  
368  
369  
370  
371  
372  
373  
374  
375  
376  
377  
378  
379  
380  
381  
382  
383  
384  
385  
386  
387  
388  
389  
390  
391  
392  
393  
394  
395  
396  
397  
398  
399  
400  
401  
402  
403  
404  
405  
406  
407  
408  
409  
410  
411  
412  
413  
414  
415  
416  
417  
418  
419  
420  
421  
422  
423  
424  
425  
426  
427  
428  
429  
430  
431  
432  
433  
434  
435  
436  
437  
438  
439  
440  
441  
442  
443  
444  
445  
446  
447  
448  
449  
450  
451  
452  
453  
454  
455  
456  
457  
458  
459  
460  
461  
462  
463  
464  
465  
466  
467  
468  
469  
470  
471  
472  
473  
474  
475  
476  
477  
478  
479  
480  
481  
482  
483  
484  
485  
486  
487  
488  
489  
490  
491  
492  
493  
494  
495  
496  
497  
498  
499  
500  
501  
502  
503  
504  
505  
506  
507  
508  
509  
510  
511  
1
2
3
4
5
6
7
8
9
36 68 100  
37 69 101  
38 70 102  
39 71 103  
40 72 104  
41 73 105  
10 42 74 106  
11 43 75 107  
12 44 76 108  
13 45 77 109  
14 46 78 110  
15 47 79 111  
16 48 80 112  
17 49 81 113  
18 50 82 114  
19 51 83 115  
20 52 84 116  
21 53 85 117  
22 54 86 118  
23 55 87 119  
24 56 88 120  
25 57 89 121  
26 58 90 122  
27 59 91 123  
28 60 92 124  
29 61 93 125  
30 62 94 126  
31 63 95 127  
DIP-switch Position  
DMX Address  
ST-3000LED User Manual  
14  
2009-12-10/14:04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix  
DMX CHANNEL VALUES  
NOTE!  
Please read all instructions carefully on fixture DMX control mode and addressing.  
DMX channels 2, and 3 functions are determined by the current settings of channel 1. For example,  
while Channel 1 is set between 000 and 029 the following conditions will apply;  
.
.
Channel 2 will control Strobing from 0% to 100%  
Channel 3 will control Dimming Intensity from 100% to 0%  
Channel  
Value  
Function  
Ch 2  
Ch 3  
000 039 Dimmer /Strobe  
Strobe  
Mode  
0 255  
040 079 Program 1  
080 119 Program 2  
120 159 Program 3  
160 199 Program 4  
200 239 Program 5  
240 255 Sound  
Intensity  
100%0%  
Speed  
Slow Fast  
1
No Function  
ST-3000LED User Manual  
15  
2009-12-10/14:04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix  
TECHNICAL SPECIFICATIONS  
WEIGHT & DIMENSIONS  
Length...........................................................................................................................356 mm (14 in)  
Width..........................................................................................................................248 mm (9.75 in)  
Height ..........................................................................................................................165 mm (6.5 in)  
Weight......................................................................................................................... 2.22 kg (4.9 lbs)  
Master Pack.................................................................................................(4 pcs) 12.84 kg (28.3 lbs)  
POWER  
Autoswitching power supply ............................................................................100~240 VAC, 50/60 Hz  
Current draw @ 120 V....................................................................................12 W, 0.1 A, 0.2 A inrush  
Current draw @ 230 V....................................................................................13 W, 0.2 A, 0.3 A inrush  
FUSE  
Main.......................................................................................................... 20 mm Glass 2 A Fast Blow  
LED  
Quantity ..................................................................................................................... 192 Total (white)  
PHOTO OPTIC  
Beam Angle ........................................................................................................................... 21° x 24°  
Field Angle............................................................................................................................. 40° x 43°  
Illuminance.................................................................................................................1,.321 lux @ 1 m  
Color Temperature....................................................................................................... 6,500K~8,000K  
CONTROL & PROGRAMMING  
Data input ............................................................................................. locking 3-pin XLR male socket  
Data output ........................................................................................ locking 3-pin XLR female socket  
Data pin configuration ............................................................................pin 1 shield, pin 2 (-), pin 3 (+)  
Protocols.....................................................................................................................DMX-512 USITT  
DMX Channels....................................................................................................................................3  
ORDERING INFORMATION  
LED Techno Strobe...................................................................................................... ST-3000LED  
TECHNICAL SUPPORT  
Address: Service Dept.  
3000 N 29th Ct, Hollywood, FL 33020 (U.S.A.)  
Support (Email): [email protected]  
Telephone: (954) 929-1115 - (Press 4)  
Fax: (954) 929-5560 - (Attention: Service)  
ST-3000LED User Manual  
16  
2009-12-10/14:04  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Black Decker Rice Cooker RC600 User Manual
Bosch Power Tools Drill 400 Series XPR User Manual
Boss Audio Systems Stereo System BV9566BI User Manual
Breville Slow Cooker BSC300 User Manual
Briggs Stratton Battery Charger PC300 User Manual
Broil King Food Warmer TBS 5S User Manual
Cadillac Automobile 2011 DTS User Manual
Cannon All in One Printer PIXMA MG5320 User Manual
Chauvet Speaker 360Z LED User Manual
Cisco Systems Modem EPC3212 User Manual