CHARNWOOD
Country 8 MkII and Country 12 MkII
Flat Top, Low Canopy & High Canopy
Multifuel Roomheaters
Operating
and
Installation Instructions
Bishops Way, Newport, Isle of Wight, PO30 5WS, U.K.
Tel: (01983) 537799 Fax: (01983) 537788
E-Mail: [email protected]
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATING INSTRUCTIONS FOR THE
CHARNWOOD
COUNTRY 8 MkII & COUNTRY 12 MkII
Before lighting the stove check with
the installer that the work and checks
described in the Installation
Instructions have been carried out
correctly and that the chimney has
been swept, is sound and free from
any obstructions.
Airwash
Control
Closed
Wood
Open
Only dry well seasoned wood should
be burnt on this appliance as burning
wet unseasoned wood will give rise to
heavy tar deposits in the stove, on the
glass and within the chimney. For the
same reason hard wood is better than
soft wood. Burning wet unseasoned
wood will also result in considerably
reduced outputs. The wood should be
cut and split and then left to season
in a well ventilated dry place for at
least one year but preferably two
years before use.
Door handle
To Open
Riddler
Lever
FUELS
The following fuels may be burnt on
this stove. Please pay careful
attention to the special points made
with each type of fuel as they will
help you to get the best from your
stove. It must be remembered that
only smokeless fuels may be burnt in
smoke control areas on this stove. If
you are not sure whether you are in a
smoke control area, then please check
with your Local Authority.
Door Airslide
Closed......Open
Door Airslide
Open......Closed
Cou n tr y 8
Peat
Ensure that the peat is well dried
before use. Burning wet peat will
give rise to heavy tar deposits and
reduced outputs.
Airwash
Control
Closed
Open
Door handle
To Open
Smokeless Fuels
PETROLEUM COKE IS NOT
SUITABLE FOR USE ON THIS
APPLIANCE. ITS USE WILL
INVALIDATE THE
The recommended smokeless fuels
which are suitable for use in smoke
control areas on this stove are as
follows:
Riddler
Lever
Ancit, (Phurnacite Plus)
Anthracite Large Nuts,
Cosycoke
Homefire,
Maxibrite,
Phurnacite,
Sunbrite Doubles,
Welsh Dry Steam Coal (Large Nuts).
GUARANTEE.
Door Airslide
Open......Closed
Door Airslide
Closed......Open
At first you may find it helpful to try
several fuels to find the most suitable.
If you are unable to obtain the fuel
you want ask your supplier, or an
approved fuel distributor to suggest
an alternative.
Cou n tr y 12
F ig. 1. St ove Con t r ols
bars are vertical with gaps in between
allowing the primary combustion air
to come up through the grate and
through the fuel bed.
Coal
DOOR OPERATION
Housecoal doubles, trebles or cobbles
may all be burnt. Do not use singles,
small nuts, or coal dust
Use the door opening and ashpan tool
to open and close the doors. Turn the
right-hand door knob anti-clockwise
to open and clockwise to close.(see
Fig. 1)
2) In the wood position the grate bars
are horizontal, allowing the
It is important that large size coal is
used (ie. larger than 2 inch or 50 mm
in size). The coal should be dry.
combustion air to come round the
sides of the grate and over the top of
it. When in the wood position ash is
able to build up on the grate as is
necessary for effective wood or peat
burning.
MULTIFUEL GRATE
When burning bituminous coal a
little extra care is needed. Please take
note of the section "Special Points
For Burning Coal".
Your Charnwood stove is fitted with
a multifuel grate which enables both
solid fuels and wood to be burned
equally effectively. The grate has two
positions:-
Movement of the grate from one
position to the other is effected using
the tool supplied as shown in Fig. 2.
The grate is put into the solid fuel
1) In the solid fuel position the grate
Page 3
TW16 3/99
Download from Www.Somanuals.com. All Manuals Search And Download.
position by moving the tool up until
the handle is in the 1 o'clock
normal and will cease after a short
time, but meanwhile the room should
be kept well ventilated.
not overfill to prevent fuel from
spilling over the top of the front fire
bars.
position. The grate is put into the
wood position by moving the tool
down until the handle is in the
5 o'clock position. To riddle the
appliance when burning solid fuels
the tool should be moved between the
1 o'clock and 3 o'clock positions
several times. When burning wood or
peat the ash should be allowed to
build up and riddling should only be
carried out once or twice a week.
At first only light a small fire and
burn it slowly for two hours to allow
any residual moisture in the bricks to
evaporate.
Care should be taken especially when
burning wood that fuel does not
project over the front fire bars or
damage to the glass may be caused
when the doors are closed, it can also
cause the glass to black up .
When relighting the stove, riddle (if
burning solid fuel), remove any
clinker from the firebed and then
empty the ashpan.
ASH CLEARANCE
The ashpan should be emptied
CONTROLLING THE
FIRE
regularly before it becomes too full.
Never allow the ash to accumulate in
the ashpan so that it comes in contact
with the underside of the grate as this
will seriously damage the grate bars.
The ashpan is handled using the tool
provided. Care should be taken to
ensure that ash is cool before
The rate of burning and hence the
output is controlled by the door air
slides and the airwash control (see
Fig. 1).
The door airslides are used when
lighting and requiring rapid heating.
They may be left slightly open to help
keep the glass clean.
emptying it into plastic liners or bins.
Solid Fuel
To make ash removal easier there is a
special Charnwood ash carrier
available. This may be purchased
from your supplier or, in case of
difficulty, from ourselves.
The airwash control is used most of
the time to control the burning rate
and to keep the glass clean. Fully
extended gives full airwash for faster
burning and clean glass whereas fully
closed gives slow overnight burning.
It will not be possible to keep the
glass clean if this control is fully
closed, particularly after refuelling.
Riddle
SPECIAL POINTS
WHEN BURNING
COAL
When loading the stove take care not
to smother the fire, instead fill the
firebox in two stages waiting between
each stage for the flames to appear
above the fire.
Wood
F ig. 2. Gr a t e Op er a t ion
LIGHTING
RIDDLING
When burning solid fuels riddling
twice a day is usually sufficient.
When burning wood or peat, ash
should be allowed to build up and
generally weekly riddling will be
sufficient. The fire should be riddled
with the doors shut (see Fig 2.) Place
the tool onto the riddling lever and
rotate between the 1 o'clock and
3 o'clock positions several times. Too
much riddling can result in emptying
unburnt fuel into the ashpan and
should therefore be avoided. If any
clinker forms it should be removed
from the firebed. After riddling, the
grate should be put back into the
solid fuel or wood position as
After a period of slumbering always
turn the air control up to maximum
and wait until flames appear above
the fuel bed before opening the doors.
The stove may be lit using dry
Burning coal will produce more soot
deposits than other fuels, especially if
the fire is run at low levels for long
periods. It is therefore vital to clean
the throat plate regularly, weekly
cleaning is recommended.
kindling wood and paper or fire
lighters. Set the grate into either the
wood position or the solid fuel
position as required. Place the paper,
or fire lighters, and kindling on the
grate and cover with approximately 2
inches of fuel. Open the air slides in
the doors and open the airwash
control fully (see fig. 1). Light the
paper or fire lighters. Close the doors
until the fuel is well ignited then load
with fuel and adjust the air controls
to the required setting.
Never fully close the Airwash control
when burning coal.
SPECIAL POINTS
WHEN BURNING
WOOD AND PEAT
required (the tool should be in the
1 o'clock position for solid fuel or in
the 5 o'clock position for wood).
On initial lighting, the stove may
smoke and give off an odour as the
silicon paint with which the firebox
is painted reacts to the heat. This is
The grate should be kept in the wood
burning position and should not be
riddled until the ash becomes so deep
REFUELLING
Keep the firebox well filled but do
Page 4
TW16 3/99
Download from Www.Somanuals.com. All Manuals Search And Download.
that it begins to block the passage of
air into the firebox at the side of the
grate. When this is the case do not
remove all of the ash using the
riddling mechanism but keep a layer
about half an inch thick as this
enables the wood to burn more
effectively. When burning wood or
peat use the airwash control in the
same way as described (see
withstand high temperatures. Before
cleaning the glass open the doors and
allow them to cool. Clean the glass
using a damp cloth and then wiping
over with a dry cloth. Any stubborn
deposits on the glass may be removed
with a proprietary stove glass cleaner
or ceramic hob cleaner. Some
left ajar. It is also advisable to sweep
the chimney and clean out the fire.
Spraying the inside of the doors and
firebox with a light oil, such as
WD40, will also help to keep all
internal parts working well.
After long periods where the fire has
been out of use, the chimney and
appliance flueways should be cleaned
before lighting.
deposits on the glass may be burnt off
simply by running the fire at a fast
rate for a few minutes. Do not use
"CONTROLLING THE FIRE" )but
keep the door airslides closed once
the desired temperature has been
reached.
Door Seals
For the fire to operate correctly it is
important that the door seals are in
good condition. Check that they do
not become worn or frayed and
replace them when necessary.
OVERNIGHT
BURNING
Servicing
For overnight burning the fire doors
must be closed.
It is recommended that the fire is
serviced once a year to keep it in first
class working order. After cleaning
out the firebox thoroughly, check that
all internal parts are in good working
order, replacing any parts that are
beginning to show signs of wear.
Check that the doors seals are in
good condition and that the doors
seal correctly. A servicing guide is
available on request.
Throat Plate
When burning solid fuel the ashpan
should be emptied and the fire
Tool
riddled. The air controls should be
turned up to maximum for a brief
period and then when the fire is
burning brightly it should be loaded
with fuel. When the new fuel has
ignited, the door airslides should be
almost closed and the airwash control
moved to a low setting. Some
Pull Forward and Swing Down
Cou n tr y 8
THROAT PLATE AND
FLUEWAY CLEANING
experimentation will be necessary to
find the settings most suitable for the
particular fuel used and the draw on
the chimney. To revive the fire,
empty the ashpan, riddle, and open
the air controls to maximum. When
the fire is burning well load on more
fuel as necessary and move the air
controls to the desired setting.
Throat Plate
It is important that the throat plate
and all the stove flueways are kept
clean. When burning smokeless fuels
they should be cleaned monthly.
When burning other fuels they should
be cleaned at least once a week, and
more frequently if necessary. It is not
necessary to let the fire out
Tool
Pull Forward and Swing Down
When burning wood use large logs
rather than small ones. Proceed as
above, but do not riddle the fire
either when shutting down or
reviving.
Cou n t r y 12
completely to carry out these
operations.
F ig. 3. Th r oa t P la te Loca tion
The throat plate is lowered using the
tool. The front of the throat plate is
pulled forward and then lowered as
shown in figure 3. Any sooty deposits
should then be swept from the plate
and into the fire.
MAINTENANCE
abrasive cleaners or pads as these can
scratch the surface which will weaken
the glass and cause premature failure.
Aerosol spray cleaners should not be
used near the appliance whilst it is
under fire.
Cleaning
The stove is finished with a high
temperature paint which will
withstand the temperatures
encountered in normal use. This may
be cleaned with a damp lint-free cloth
when the stove is cold. Should
re-painting become necessary, high
temperature paints are available from
your supplier or from stove shops.
Return the throat plate to its correct
position - raise the front of the plate,
push it back and then lower it onto
the retaining lugs.
When not in use
If the fire is going to be out of use for
a long period, (for instance in the
summer,) then to prevent condensa-
tion, and hence corrosion, the
thermostat should be left at the
maximum setting and the main doors
CHIMNEY SWEEPING
The chimney should be swept at least
twice a year. Where a top outlet is
used it will generally be possible to
Cleaning the Glass
The glass in the doors is a special
ceramic glass which is able to
Page 5
TW16 3/99
Download from Www.Somanuals.com. All Manuals Search And Download.
sweep the chimney through the
appliance.
therefore, when lighting the stove
allow the firebed to become well
established before closing the
airslides. This may also be necessary
when re-fuelling the stove.
blockage, and clean if required.
d) Do not attempt to re-light the
fire until cause of fume has been
identified, if necessary seek
professional advice.
First remove the side fire plates, front
firebars and the throat plate. Then
sweep the chimney ensuring that soot
is removed from all horizontal
surfaces after sweeping.
b) When re-fuelling keep the fuel as
far back from the front firebars as
possible, do not try to fit too much
fuel into the firebox.
The most common cause of fume
emission is flueway or chimney
blockage. For your own safety these
must be kept clean.
In situations where it is not possible
to sweep through the appliance the
installer will have provided
alternative means, such as a soot
door. After sweeping the chimney the
appliance flue outlet and the flue pipe
connecting the stove to the chimney
must be cleaned with a flue brush.
c) Never completely close the airwash
control - as a guide it should be at
least a quarter open.
Fire blazing out of
control
d) The airslides in the doors may be
kept slightly open to assist in keeping
the glass clean.
Check that :
a) The doors are tightly closed.
b) The airslides are turned down to
the minimum setting.
c) The airwash control is closed.
d) A suitable fuel is being used.
e) Door seals and airwash slide are
intact.
After clearing any soot from within
the stove, replace the throat plate (see
fig. 3), the front firebars, and side
fireplates.
e) Wet wood or logs overhanging the
front firebars will cause the glass to
blacken.
It is always more difficult to keep the
glass clean when running the stove
very slowly for long periods.
Different types of sweep's brushes are
available to suit different flueways.
For standard brick chimneys a wire
centre sweep's brush fitted with a
guide wheel is recommended. For
prefabricated insulated chimneys the
manufacturers instructions with
regard to sweeping should be
consulted.
Chimney Fires.
If blackening of the glass still occurs
check that the top of the stove is
bolted on securely, and that the seal
between the top and the body is
intact. Also check that all flue
connections and the blanking plate
are well sealed. It is also important
that the chimney draw is sufficient,
(when the chimney is warm a
draught reading of at least 0.10
inches water gauge should be
obtained), and that it is not affected
by down-draught.
If the chimney is thoroughly and
regularly swept, chimney fires should
not occur. However, if a chimney fire
does occur turn the controls to the
minimum setting, and tightly close
the doors of the appliance. This
should cause the chimney fire to go
out in which case the control should
be kept at the minimum setting until
the stove has gone out. The chimney
and flueways should then be cleaned.
If the chimney fire does not go out
when the above action is taken then
the fire brigade should be called
immediately.
TROUBLE SHOOTING
Fire Will Not Burn.
Check that:
a) the air inlet is not obstructed in
any way,
When burning coal some blackening
of the glass may occur below the
level of the front firebars. This will
not obscure the view of the fire or
affect its performance.
b) chimneys and flueways are clear,
c) that a suitable fuel is being used,
d) that there is an adequate air supply
into the room,
e) that an extractor fan is not fitted in
the same room as the stove.
f) there is sufficient draw in the
chimney, (once the chimney is warm
a draught reading of at least 0.10
inches water gauge should be
obtained).
After a chimney fire the chimney
should be carefully examined for any
damage. Expert advice should be
sought if necessary.
Fume Emission.
Warning Note: Properly installed
and operated this appliance will not
emit fumes. Occasional fume from
de-ashing and re-fuelling may
occur. Persistent fume emission is
potentially dangerous and must not
be tolerated. If fume emission does
persist, then the following
Door Glass Blacks Up
Keeping the glass clean requires a
certain amount of experimentation
due to the differences in the draw of
different chimneys. The following
points should be noted and with a
little care should enable the glass to
be kept clean in most situations:
immediate actions should be taken:
a) Open doors and windows to
ventilate the room.
b) Let the fire out and safely
dispose of the fuel from the
appliance.
a) The airwash relies on a supply of
heated air to keep the glass clean,
c) Check for flue or chimney
Page 6
TW16 3/99
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS FOR THE
CHARNWOOD
COUNTRY 8 MkII & COUNTRY 12 MkII
smokeless fuel over a four hourly
re-fuelling cycle.
doubt about the chimney seek expert
advice.
HEALTH AND SAFETY
PRECAUTIONS
CHIMNEY
HEARTH AND FIRE
Please take care when installing the
stove that the requirements of the
Health and Safety at Work Act 1974
are met.
SURROUND
In order for the appliance to perform
satisfactorily the chimney height
must not be less than 4 metres
measured vertically from the outlet of
the stove to the top of the chimney.
The chimney should preferably be
175 mm (7 inches) or 200mm (8
inches) internal diameter or square
with sides of 175mm or 200mm
internally and must not be less than
150 mm (6 inches) internal
The stove must stand on a fireproof
hearth and must be situated at least
300mm (12 inches) from any
combustible material. The positioning
of the stove and the size of the hearth
are governed by building regulations
for Class 1 appliances. These
building regulations state that the
hearth must extend in front of the
stove by at least 300mm (12 inches)
and to the sides of the stove by at
least 150mm (6 inches). If in doubt
as to the positioning of the stove
expert advice should be sought either
from the supplier or the local
Some types of fire cement are caustic
and should not be allowed to come
into contact with the skin. In case of
contact wash with plenty of water.
If there is a possibility of disturbing
any asbestos in the course of
installation then please use
appropriate protective equipment.
diameter or 150 x 150mm internal
square.
There must not be an extractor fan
fitted in the same room as the stove
as this can cause the appliance to
emit fumes into the room.
If an existing chimney is to be used it
must be swept and checked, it must
be in good condition, free from
cracks and blockages, and should not
have an excessive cross sectional
area. If you find that the chimney is
in poor condition then expert advice
should be sought regarding the
necessity of having the chimney
lined. If it is found necessary to line
the chimney then a lining suitable for
Solid Fuel must be used.
building inspector.
There must be an adequate air supply
into the room in which the appliance
is installed totalling at least 100
square cm. (16 square inches) to
provide combustion air. This is
particularly necessary if the room is
double glazed.
The fireplace must allow good
circulation of air around the
appliance to ensure that maximum
heat is transferred to the room and
also to prevent the fireplace from
overheating. A gap of 150mm
(6 inches) each side and 300mm
(12 inches) above the appliance
should give sufficient air circulation.
If a wooden mantelpiece or beam is
used in the fireplace it should be a
minimum of 460mm (18 inches), and
preferably 600mm (24 inches) from
the appliance. In some situations it
may be necessary to shield the beam
or mantelpiece to protect it.
In addition to these instructions the
requirements of BS.8303 and
BS.6461 Pt 1&2; 1984 must be
fulfilled. Local Authority Bylaws and
Building Regulations regarding the
installation of Solid Fuel burning
appliances, flues and chimneys must
also be observed.
If there is no existing chimney then a
prefabricated block chimney or a twin
walled insulated stainless steel flue to
BS.4543 can be used either internally
or externally. These chimneys must
be fitted in accordance with the
manufacturers instructions and
Building Regulations.
PERFORMANCE
In order for the airwash to operate
correctly there must be an air gap
behind the appliance of at least
25mm.
Single wall flue pipe is suitable for
connecting the stove to the chimney
but is not suitable for using for the
complete chimney.
The output of the Country 12 LC and
FT is 12.0 kW (40,900 Btu/h), the
Country 12 HC output is 12.5kW
(42650 Btu/h). The output of the
Country 8 LC and FT is 8.0 kW
(27,300 Btu/h) the Country 8 HC
output is 8.5 kW (29,000 Btu/h). The
optional add-in boilers for all
Country models have an output of
2.9 kW (10,000 Btu/h), if the boiler
is fitted then the heat output to the
room will be reduced by this amount.
If it is found that there is excessive
draw in the chimney then a draught
stabilizer should be fitted.
HOT WATER SYSTEM
The optional add-in boiler which may
be fitted in the appliance has an
output sufficient for domestic hot
water heating. If the boiler is fitted
then the room heating will be
reduced.
It is important that there is sufficient
draw in the chimney and that the
chimney does not suffer from
down-draught. When the chimney is
warm the draw should be not less
than 0.10 inches water gauge. If in
The outputs were obtained burning
Page 7
TW16 3/99
Download from Www.Somanuals.com. All Manuals Search And Download.
The hot water system should be a
gravity circuit and must be correctly
vented as shown in Fig. 4.
firebrick. Knock out the knock-outs
for the boiler tappings in the back of
the firebox.
Soot Door
in Side or Rear
Of Chimney
The steel boiler together with a
double feed indirect hot water storage
cylinder to BS:1566 part 1 should be
used in most situations, unless the
appliance is to be fitted in a soft
water area in which case the stainless
steel boiler may be used with a direct
hot water cylinder.
Remove the backnuts and fibre
Register Plate
washers from the boiler tappings and
fit the boiler into the appliance. Place
the fibre washers over the tappings
on the outside of the appliance and fit
the backnuts, ensuring that the boiler
is held tightly against the rear inside
face of the appliance and that the top
edge of the boiler is level or runs
uphill to the flow tapping.
All pipework in the primary circuit
must be 28mm diameter and the flow
pipe must rise continuously from the
boiler to the open vent.
F ig 5. Ver t ica l Regist er P la t e
With Br ick ed Up F ir ep la ce
Gaps between the boiler and the
firebricks should be filled with fire
cement. Replace the back fireplate,
the side fireplates and the front
firebar. On the Country 12, fit the
new throat plate.
If an indirect cylinder is used then
the primary circuit should be filled
with a suitable inhibitor to prevent
the build up of scale and corrosion.
Alternative
Soot Door
Positions
Connect the boiler to the heating
system ensuring that the flow pipe
rises from the boiler. Fill the system
with water and check for leaks.
FITTING THE
OPTIONAL ADD-IN
BOILER
Register Plate
With Soot Door
CONNECTIONS TO
FLUES
The boiler replaces the rear firebrick.
On the Country 8 the boiler also
replaces the throat plate, on the
Country 12 a special throat plate,
(part no. 010/BV35), is required.
There are several ways of connecting
the stove to the flue. These are
illustrated in figures 5 to 8.
Before fitting the boiler, remove the
front firebars, the side and back fire
plates, the throat plate and the rear
If the vertical rear flue connector is
used and no boiler is fitted then the
F ig. 6. Hor izon t a l R egist er P la t e
With Rea r F lu e Con n ection
22mm Open Vents
Feed and Expansion Tank
Cold Water Tank
Overflow
Overflow
Alternative
Soot Door
Positions
Domestic Hot Water Draw Off
Register Plate
With Soot Door
Drain Cock
Indirect Hot Water Cylinder
Drain Cock at Lowest Point
F ig. 7. Hor izon t a l R egist er P la t e
With Top F lu e Con n ection
F ig. 4. Typ ica l Gr a vity Hot Wa ter System
Page 8
TW16 3/99
Download from Www.Somanuals.com. All Manuals Search And Download.
Back of the Stove
chimney or in the register plate.
Various types and positions of soot
doors are shown in figures 5 to 8.
Blanking Plate
Alternative
Soot Door
Positions
PRE LIGHTING
CHECK
Clamping Plate
with fold horizontal
Before initial lighting the following
points should be checked :-
Register Plate
With Soot Door
Blanking Plate
1. The bottom grate bars must all be
fitted and should move freely and
easily when the riddling mechanism
is operated.
Clamping plate finishes
flush with inside face of
firebox top and bottom.
2. The plates round the sides and
back of the grate must be in position
and sitting correctly.
Seal Blanking Plate
with fire cement
F ig. 8. Hor izon ta l Register
P la t e Wit h Op t ion a l Ver t ica l
Rea r F lu e Con n ector
3. The throat plate must be fitted in
the roof of the appliance and should
be checked to ensure that it has not
become dislodged in transit. The
method of location and positioning of
the throat plate is shown in fig 3.
F ig. 9. F lu e Bla n k in g P la t e.
chimney may be swept through the
appliance.
4. The top or canopy must be securely
bolted to the body of the stove using
the fixings provided to ensure proper
sealing.
Horizontal lengths of flue must be
kept to a minimum and should not be
more than 150mm (6 inches) long.
The sealing face of the flue collar
should be coated with fire cement
before fixing to the body of the stove
using the two screws provided. The
blanking plate must be removed,
sealed with fire cement and refitted,
care being taken to ensure that the
fold on the blanking plate is in line
with the lugs on the firebox as shown
in Fig. 9. Ensure that the clamping
plate does not prevent the throat plate
from seating correctly. All flue
connections must be well sealed.
Ensure that the flat top or canopy is
securely bolted to the body of the
stove.
COMMISSIONING
On completion of the installation and
after allowing a suitable period of
time for the fire cement and mortar to
dry out, the stove should be lit and
checked to ensure that smoke and
fumes are taken from the appliance
up the chimney and emitted safely.
Also check all joints and seals. On
completion of the installation and
commissioning please leave the
operating instructions with the
customer and advise them on the use
of the appliance.
SOOT DOORS
It is possible to pass a 16 inch
diameter sweeps brush through the
appliance but in most back outlet
installations it will be necessary to
have a soot door to enable the
chimney to be swept. This may either
be in the actual brickwork of the
Page 9
TW16 3/99
Download from Www.Somanuals.com. All Manuals Search And Download.
460
106
552
46
Ø154
1072
1012
Country 8 HC
(High Canopy)
587
513
322
381
513
71
299
110
526
469
126
552
46
Ø154
Country 8 LC
(Low Canopy)
812
752
587
513
71
322
110
381
299
526
508
513
461
125
46
Ø154
Country 8 FT
(Flat Top)
699
639
587
513
71
322
110
381
513
299
526
Country 8 MkII Dimensions
(All dimensions are in mm)
Page 10
TW16 3/99
Download from Www.Somanuals.com. All Manuals Search And Download.
480
106
655
Ø154
45
1158
1098
Country 12 HC
(High Canopy)
584
462
320
386
518
210 180
489
125
655
Ø154
45
853
Country 12 LC
(Low Canopy)
793
584
462
320
386
518
210 180
468
125
595
Ø154
45
Country 12 FT
(Flat Top)
718
658
584
462
320
386
518
210 180
616
Country 12 MkII Dimensions
(All dimensions are in mm)
Page 11
TW16 3/99
Download from Www.Somanuals.com. All Manuals Search And Download.
|