E SERIES 1200
Installation Instructions
234 FISCHER AVENUE z COSTA MESA, CA 92626
(714) 424-6500
z
(800) 840-0288
z
(714) 424-6510 FAX
z
E-Mail: [email protected]
© 2001, CHANNEL VISION™
Download from Www.Somanuals.com. All Manuals Search And Download.
E Series 1200 Basic Setup
company input and the CVT combiner. This prevents the CVT signal from
propagating back up the input line.
Another way to prevent leakage from your system is to cap all unused coax
cable ports on you network with appropriate terminators.
Cable or
Antenna
AV In
Bandpass filters stop unwanted frequencies while passing all others along.
They're handy if a channel you want to use for a CVT source is already in use.
3102 Filter
Modulator
Channel Vision
Taps are used to redirect a portion of a signal from the "main" trunk line while
passing the remaining signal strength through. For example, a 12dBmV tap
would pass 29dBmV from a 30dBmV trunk line signal and pass the remaining
18dBmV to a branch line. (Minor signal loss of 1dB would occur in the trunk
line leaving 29dBmV.)
MULTI ROOM VIDEO TECHNOLOGY
CVT - 15PIA
RF Out
HS-2
Demodulators are used to demodulate the output of a cable box converter,
making it possible to assign the cable signal to any channel (cable boxes
usually limit your choices to channel three or channel four). Use a demodulator
to "condition" the cable signal before assigning it to a CVT input line.
HS-8
Satellite Receiver
Adjustments
To TV's
Video Level Adjustment: Adjust the incoming video source base band level.
Use only to increase brightness and balance the channels for consistent
contrast.
FCC Regulations – the Cable TV Act
Channel Up/Down: Changes the modulated channel. Press and hold Select
for 2 seconds or until front light blinks to allow channel up/down to work.
“Cable home wiring” is the cable wiring located inside a Cable TV sub-
scriber’s home or apartment that has been installed by a cable operator or
its contractor. It does not include such items as amplifiers, converters,
decoder boxes or remote control units.
Channel
Push
Channel
Push
Channel
Push
Channel
Push
Cable/UHF
Cable/UHF
Cable/UHF
Cable/UHF
After a subscriber voluntarily terminates cable service, the cable operator
may take one of two action:
1. Leave the home wiring in place.
2. Notify the consumer that it will remove the wiring unless the
consumer purchases it from the cable operator on a per-foot re
placement cost basis.
Factory Preset
Up 1
65/14
66/15
67/16
68/17
69/18
70/19
71/20
72/21
73/22
74/23
75/24
76/25
77/26
78/27
79/28
80/29
81/30
82/31
83/32
84/33
85/34
86/35
87/36
88/37
89/38
90/39
91/40
92/41
93/42
94/43
Up 15
Up 16
Up 17
Up 18
Up 19
Up 20
Up 21
Up 22
Up 23
Up 24
Up 25
Up 26
Up 27
Up 28
Up 29
95-99/42
100/43
101/44
102/45
103/46
104/47
105/48
106/49
107/50
108/51
109/52
110/53
111/54
112/55
113/56
Not Used
Down 36
Down 35
Down 34
Down 33
Down 32
Down 31
Down 30
Down 29
Down 28
Down 27
Down 26
Down 25
Down 24
Down 23
118/61
119/62
120/63
121/64
122/65
123/66
124/67
125/68
126/69
127/70
128/71
129/72
130/73
131/74
132/75
Down 18
Down 17
Down 16
Down 15
Down 14
Down 13
Down 12
Down 11
Down 10
Down 9
Up 2
Up 3
Up 4
Up 5
Up 6
Up 7
If the wiring was previously transferred or sold to the subscriber, the sub-
scriber owns it; and the cable company cannot remove it or restrict its use,
regardless of the reason for service termination.
Up 8
Up 9
Up 10
Up 11
Up 12
Up 13
Up 14
Down 8
Down 7
If the subscriber does not already own the wiring and declines to purchase
it from the cable operator, the cable operator may remove the home wiring
within 30 days of the subscriber’s refusal. The cable company must re-
move the wiring at no charge to the subscriber, and must pay the cost of
any damage caused by removing the wiring.
Down 6
Down 5
Down 4
114/57
115/58
116/59
117/60
Down 22
Down 21
Down 20
Down 19
133/76
134/77
135/78
Down 3
Down 2
Down 1
To leave the wiring inside and remove the wiring outside a subscriber’s
home, a cable operator may, for single unit dwellings, sever the cable ap-
proximately 12 inches outside the point where the cable enters the outside
wall of the subscriber’s home.
Channel up and down buttons are in increments of one. The E-1200 is
factory set for CATV 65.
For multiple unit dwellings, the cable operator may sever the wire approxi-
mately 12 inches outside the point where the cable enters the subscriber’s
individual dwelling unit, except in cases of “loop-through” or other similar
series wire configurations that are not covered by the home wiring rules.
If the cable company fails to remove the wiring within 30 days of the sub-
scriber’s refusal to purchase it, the cable operator forfeits its right to the
wiring and may not remove it or restrict its use at any later time.
System Installation Checklist
A cable operator will not be held responsible for any signal leakage that
occurs from the home wiring once the cable operator ceases providing
service over that wiring.
1. Try for 10dB of signal strength at each television. Use a little more for big
screen TV's. Remember, Uncle Sam doesn't like more than 15.5dB of signal
going into any TV.
Download from Www.Somanuals.com. All Manuals Search And Download.
2. When laying out your system, there will be approximately 5dB of
signal loss per 100' of RG6.
3. Be sure ALL of your splitters and amplifiers are broadband.
Splitters should be 5MHz to 1GHz, and amps should be 40MHz
to 1GHz.
4. Check and make sure that all televisions are set up for the proper
frequency spectrum (i.e. UHF or cable).
5. Make sure that the channels you want to modulate on have “clean
snow“. No lines or interference.
6. Use a low pass filter on every installation to clean up the
frequencies the modulator will be assigned to and keep any
potential interference out of the system. Model 3102, cleans up
channel 64, 84, 105 and above.
7. Allow 1 to 2 channel spacing between modulated channels and
"active" channels.
8. Always compensate for insertion loss with splitters and taps.
There will always be a drop in antenna/cable signal strength
when combining a modulator to an existing system (because of
Trouble Shooting
Trouble shooting any system can make or break the entire
installation. Here are the most common problems and solutions. After
trying these solutions, call 800/840-0288 for 24 hour technical
assistance. Calls before 8am and after 5pm pacific standard time will
be returned by the technician on call.
Snowy Picture : No Modulation
This is a problem of the TV and the modulator not "talking" to each
other.
insertion
the
9. When
loss with
combiner).
combining
signal with
modulated
make sure
equal signal
the point of
combiner
signal does
the other
1. Verify the modulator is set up for the proper TV channel band.
Cable TV or antenna? If the unit uses dip switches to set the
channel band, was the unit powered down during or after the
switches were reset to the proper band? If the unit uses a
jumper check for proper placement.
2. Verify the TV is set up on the proper TV channel band. Use
"Air" for UHF channels or Cable for Ultraband channels . The
TV will have an on screen set-up menu or a switch for this
function. Also make sure the modulated channel isn't blocked
out by auto-programming. To check for the TV being set to the
wrong band, go to the equivalent channel on the other band (i.e.
to check 65 cable try 14 UHF). Add 51 channels for antenna
connection to cable channels.
Loss Key_______
Coax
RG6 per 100'
RG59 per 100'
an existing
a
signal,
to have
strength at
the
so one
not degrade
and cause
4dB
5dB
Splitter
HS-2
3.5dB
5.5dB
7dB
HS-3
HS-4
HS-6
HS-8
9.5dB
11dB
-1dB
beat
Taps - Pass Thru
Suggested dB level @ TV
8~15dB
Maximum of 15.5dBmV per
FCC Regulation
3. Check TV manual to make sure TV works on channel above 65.
4. Check all connections for a good connection.
5. Check splitters and amplifiers for 1GHz rating.
6. Try another TV, bypass all components and go directly into TV.
Black Picture : No Modulation
frequencies.
In this case, the TV and the modulator are "talking" to each other.
The video signal is not being passed through the system.
1. Verify good connections to the modulator from the video source
i.e. VCR.
2. Check video source (VCR, Sat Receiver etc.) by running the
outputs directly into the video inputs on the TV. Verify video
source is working.
10. When possible, use the lowest frequencies available for the
modulated channels. Lower channels (frequencies) have lower
signal loss on the cable runs.
11. When in doubt, run the signal a little high to the television and
use an attenuator to lower the signal strength going into the TV.
Attenuators may be combined (i.e. two -3dB attenuators. will
equal -6dB).
12. Make sure to use a well shielded coax of either RG-6 Quad or
RG-11 for long trunk runs.
13. Use RG59U Coax for composite/baseband video signals only.
14. Combine the modulator into the video distribution system as far
"up-stream" as possible.
3. Check for power at video source.
4. Disconnect modulator from system:
A) Picture goes to snow, problem is between video source and
inputs on the modulator.
B) Picture stays black, hook up the modulator.
directly to a TV eliminating all the components of the system
and check the picture.
15. If the system needs to be amplified use the amplifier as far "up-
stream" as possible.
Grainy Local Channels : Good Modulated Picture
1. Disconnect the modulator from the system and connect the local
channel feed directly to the distribution system and check TV
picture quality.
A) If the picture quality is good the insertion loss of the
combiner for the modulator is degrading the local channel
signal. Use a CVT-15PIA to compensate for the insertion
loss.
B) The other alternative is to use a 6dB tap as the combiner, put
the local channel feed on the pass through port for a minimal
loss of signal connect the modulator to the tap off port.
C) If the picture is still bad, check for a bad connection where
Download from Www.Somanuals.com. All Manuals Search And Download.
leakage may occur or if the shielding braid is touching the
center conductor.
3
Check all connectors for 75W.
2. Install model CVT-15PIA amplifier after the combiner.
Noise on the Audio
1. Insert grounding block in line and ground coax cable
before it enters the TV.
2. Use professional grade audio/video interconnect between
the components and the modulator.
Grainy Modulated Channel : Good Picture on the Cable
Channels
1. Disconnect cable channels from the system and check the
modulated channels.
O
u
c
h!!!
A) If the modulated channels are good, use a low pass filter to
"clean-up" the incoming frequencies to be modulated.
B) If the modulated channel does not improve after
disconnecting the local channels, evaluate signal loss of
modulator through the splitters and cable length of the
system. Amplify after the combiner if needed.
C) Also check the connections between modulator and the
combiner for leakage or the cable braid is touching the
center conductor.
Audio is Too Low
Use a Y-Connector to combine the left and
right audio before entering the modulator.
Herringbone in Picture on Modulated Channel
Disconnect modulator from local channels
an check modulated channel.
A) If there is programming move the
modulated channel.
B) If the picture is snowy, use a #3102-80 low pass filter
to
block noise or data coming in from cable company.
C) Separate modulated channels by two channels.
2. Make sure the attenuator adjustment on the back of the
modulator is turned to maximum output power.
3. Check output strength with field strength meter.
4. Connect modulator directly to TV and check picture quality.
5. Check bandwidth of all splitters and amplifiers for 1GHz
capability.
6. Place TV cable setting on standard, NOT HRC or IRC.
Horizontal Bars Rolling Through TV Picture
1. Check for a component of the system to introduce DC
power into the system. Disconnect that component and
check TV. If the hum bars stop, use a DC blocker down
stream from that component to block the power from
getting to the TVs.
TV Won't Tune High Enough to get Modulated Channel
1. Use an external tuner i.e. VCR or a Cable Box converter tuner
to allow the TV to view a modulated channel on a channel
through the external tuner.
2. If the modulated channel is beyond the capabilities for that TV,
the TV will not work with the system.
2. If the rolling is only on the modulated channels, check for
impedance mismatch by adjusting the video level
adjustment pot.
Cable Company Box Won't Pass a Modulated Signal
1. Connect modulator directly to TV and verify the
modulator is sending a signal the TV can receive.
2. Use model 3101 Cable Box Combiner Kit to route
the modulated signal around the cable box. See
schematic page.
Vertical Bars Rolling Through TV Picture
Check for AC power getting on the line. Use a ground
breaker in line.
Cable Company Uses All Available Channels
1. Use a low pass filter (3102) to block out channels 80 and above
for clean modulation (won't effect channels 95-99).
2. Call for pricing on a custom filter to block out a specific channel
or multiple channels.
Black and White Lines on one Local Channel
Move modulated channel up to a new channel. If problem
persists and all of the inputs of a multiple input modulator
are not being used, check default channels on modulator
to see if default channel is set to the same channel that the
problem channel is set to.
Flashing at the Top or Middle of TV Picture
1. If flashing is on modulated channels, turn up attenuator/
down gain of modulator.
Modulated Picture is Too Bright or Washed Out
1. Adjust the white video level. Adjust port on the
chassis located under the white cover plate above the channel
select to the proper brightness.
2. If using a camera, check positioning of the lens to be sure it's not
aimed at the sun or a reflection.
3. Adjust camera lens - see lens manual.
2. If flashing is on local channels, attenuate output of
amplifier.
3. Remove cable TV from system. If flash stops, install
filter #3102-__ to fix problem.
Modulated Picture is Too Dark
Picture is Tearing
1. If baseband video is being split with a Stereo
Loop Kit or loop through quad, set impedance
matching switch or potentiometer
(termination switch) to 1K W.
2. Adjust the white video level adjust pot on the
chassis located under the white cover plate
above the channel select to the proper
brightness.
Possible impedance problem. Check that impedance
switch is set to 75W.
Ghosts on the Picture
1. Terminate all unused ports with 75W terminator model
2101.
2. Check for low quality combiner in system. Replace with
high isolation combiner, HS model combiner.
Download from Www.Somanuals.com. All Manuals Search And Download.
ChannelVision
LimitedWarranty
Channel Vision Technology will repair or replace any defect in material or workmanship which occur during
normal use of this product with new or rebuilt parts, free of charge in the USA, for two years from the date of
original purchase. This is a no hassle warranty with no mail in warranty card needed. This warranty does not
cover damages in shipment, failures caused by other products not supplied by Channel Vision Technology, or
failures due to accident, misuse, abuse, or alteration of the equipment. This warranty extends only to the original
purchaser. A purchase receipt, invoice, or other proof of original purchase date will be required before warranty
repairs are provided.
Mail in service can be obtained during the warranty period by calling toll free (800) 840-0288 toll free. A Return
Authorization number must be obtained in advance and be marked on the outside of the shipping carton.
This warranty gives you specific legal rights, and you may have other rights (which vary from state to state). If a
problem with this product develops during or after the warranty period, please contact Channel Vision, your
dealer, or any factory-authorized service center.
Specifications:
RF Modulator
Video
PLL Synthesized Oscillator
NTSC
Video Performance
Differential Gain
Differential Phase
Signal/Noise Ratio
Less than 2% (0.2dB)
Less than 3 degree
Greater than 52dB
Audio
L&R Monaural/Stereo loop opt.
RF Carriers
Frequency Stability
Frequency Ranges
+1KHz
Spurious Output Rejection
Outside Carrier
Inside Carrier
Isolation
+12MHz Greater than 70dBC
UHF 471.25-855.25MHz
Ultraband 469.25-859.25MHz
UHF 14-78, Ultraband 65-135
(Exc. 95-99)
+12MHz Greater than 55dBC
Greater than 70dB
Channels
Inputs
Video
0.4V-2.7V Peak to Peak
1V RMS
Channel Width
Audio Offset
Sidebands
6.0MHz
Audio
4.5MHz
Double
Connectors
Video In
RCA Female
RCA Female
F type female
RF Output
Audio In
Maximum
30dBmV
RF Output
Gain Range
Fixed
Video Output
Audio Output
Channel Selector
1VPeak to Peak
1V RMS
Operating Temperatures
0oC to 50oC
Transformer Input
Input Voltage
Power
Up/Down selector buttons/I
Increments of one
115 VAC, 50/60Hz
8 Watts
Output Voltage
12.0 VAC C/T @ 400mA