ChannelPlus Enclosures
OpenHouse modules attach from the top
1
1) Hook from the top
2) Swing into place
3) push button to lock
H218 18” enclosure
3
Telephone Master Hub (4 lines
x
6
phones)
ChannelPlus model H616
From
Telco
Expansion
Ports
Telephones
R
T
RJ31X
4
3
2
1
R
T
R
T
Out
R
T
H236 36” enclosure
2
H290 AC outlet accessory
H254 54” enclosure
Mounting the enclosure
16”
Mounting the H290 AC outlet accessory
On
Center
Use the mounting tabs when
mounting the enclosure between
the studs and using 1/2”
wallboard.
H290 installs in either of 2 locations
Enclosure
The H290 accessory brings AC power
inside the H218, H236 or H254
enclosure. The H290 gives the
installer a clean, UL approved location
to mount power adaptors. Mount the
H290 to either the upper right or upper
left corner of the enclosure using the
four #6 screws provided. Installation
of AC outlets should be done only by a
qualified electrician.
Attach enclosure using 4 screws.
Either from mounting tabs
or inside holes.
1/8”
Enclosure
Wallboard
When using other than 1/2”
Stud
wallboard, remove the mounting tabs
and mount the enclosure to protrude
1/8” beyond the wallboard surface.
1/2” knockouts for 120VAC
14 3/8“
Mounting in existing wallboard or
surface mounting …
Remove the mounting tabs.
OEM
AC ADAPTOR
The H290 provides space for 4
standard duplex receptacles.
Wires should exit the H290 using
the grommets provided. The
grommets may be cut as shown.
Part no.: 123-456
U
L
181/8” for H218
361/8” for H236
541/8” for H254
Grab the tabs with
pliers and rock back
and forth to remove.
Installing cables
Remove knockouts as needed
and line holes with grommets provided
Grommet
Installing the cover
An old electrician’s trick …
When hanging a heavy cabinet cover,
insert nails through the mounting holes
on the cover. Guide the nails into the
mating holes on the enclosure and let
the cover hang from the nails while you
attach the screws. (We’ve included two
of these sophisticated devices for your
assistance.)
Remove paint shield and save.
Route cabling into enclosure.
After cabling is routed, reverse
paint shield and return it to the
enclosure to protect cabling.
Grounding the cabinet
When used with model H290 accessory, the grounding lug on the
H290 is used. No separate ground lug is provided on the H218,
H236 or H254. The user must install ground lugs as necessary.
If H290 is installed, fold flaps on the
paint shield to bend the shield over
the H290 AC outlet accessory.