Chaney Instrument Marine Radio 00251W User Manual

Instruction Manual  
Sportsman’s Forecaster  
models 00251W/00252W  
CONTENTS  
Set the Time, Date & Units...... 5  
Placement Guidelines ............. 6  
Using the Forecaster............... 7  
Troubleshooting ..................... 8  
Care & Maintenance.............10  
Unpacking Instructions ........... 2  
Package Contents .................. 2  
Product Registration ............... 2  
Features & Benefits: Sensor..... 2  
Features & Benefits: Display.... 3  
Setup .................................... 4  
Sensor Setup ......................... 4  
Display Setup ........................ 4  
®
Replace Intelli-Time battery ..10  
Specifications........................11  
FCC Information ...................11  
Customer Support.................12  
Warranty..............................12  
®
Intelli-Time Clock .................. 5  
Questions? Contact Customer Support at  
(877) 221-1252 or visit www.AcuRite.com.  
SAVE THIS MANUAL FOR FUTURE REFERENCE.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Features & Benefits  
6
14  
15  
7
8
16  
17  
18  
19  
20  
9
10  
11  
13  
21 12 22  
DISPLAY UNIT  
14. Learning Mode Icon  
6. Hunting or Fishing Activity Meter  
Predicts wildlife activity level. Select  
hunting, fishing, or auto-cycle  
between both.  
Disappears after weather forecast  
self-calibration is complete.  
15. 12 to 24 Hour Weather Forecast  
Self-Calibrating Forecasting pulls data  
from the outdoor sensor to generate  
your personal forecast.  
7. Pressure History Graph  
Tracks and displays the barometric  
pressure history.  
16. Moon Phase  
8. Barometric Pressure  
Arrow icon indicates the direction the  
pressure is trending.  
®
17. Intelli-Time Date  
Sets itself to the correct date.  
®
9. Intelli-Time Clock  
18. Today’s High Temperature Record  
19. Wireless Sensor Signal Strength  
20. Today’s Low Temperature Record  
21. Hunting/Fishing Mode Button  
22. Sensor Low Battery Indicator  
Sets itself to the correct time and  
automatically updates for Daylight  
Saving Time.  
10. Display Low Battery Indicator  
11. Monthly High Temperature Record  
12. Current Outdoor Temperature  
13. Monthly Low Temperature Record  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
SETUP  
Install or Replace Batteries  
AcuRite recommends high quality alkaline batteries for the best product  
performance. Heavy duty or rechargeable batteries are not recommended.  
The outdoor sensor requires lithium batteries in low temperature conditions.  
Cold temperatures can cause alkaline batteries to function improperly. Use  
lithium batteries in the outdoor sensor for temperatures below -4ºF / -20ºC.  
Outdoor Sensor  
1. Slide off the battery compartment  
cover.  
2. Insert 2 x AA batteries into the  
battery compartment, as shown.  
Follow the polarity (+/-) diagram in  
the battery compartment.  
3. Replace the battery cover.  
Display Unit  
1. Slide the stand off of the bottom  
of the display, as shown.  
2. Slide off the battery compartment  
cover.  
3. Insert 3 x AA batteries into the  
battery compartment, as shown.  
Follow the polarity (+/-) diagram in  
the battery compartment.  
4. Replace the battery cover.  
5. Replace the stand.  
PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE  
WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.  
BATTERY SAFETY: Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment which is not to be  
used for an extended period of time. Follow the polarity (+/-) diagram in the battery compartment. Promptly remove dead batteries from the device. Dispose of used  
batteries properly. Only batteries of the same or equivalent type as recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose of batteries in fire,  
as batteries may explode or leak. DO NOT mix old and new batteries or types of batteries (alkaline/standard). DO NOT use rechargeable batteries. DO NOT recharge  
non-rechargeable batteries. DO NOT short-circuit the supply terminals.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
®
Intelli-Time Clock  
Intelli-Time products are pre-programmed with the correct time and date.  
Intelli-Time technology instructs the time and date to set themselves. All you  
need to do is select your Time Zone and Daylight Saving Time preferences. The  
clock will then automatically set itself and change for Daylight Saving Time.  
Set the Time, Date & Units  
Press the “SET” button to enter SET MODE. Once in SET MODE, the  
preference you are currently setting will blink on the display.  
To adjust the currently selected (flashing) item, press and release the “  
p” or  
q
” buttons (press and HOLD to fast adjust).  
To save your adjustments, press and release the “SET” button again to adjust  
the next preference. The preference set order is as follows:  
TIME ZONE (PST MST CST EST AST HAST AKST)  
DST* (Daylight Saving Time ON or OFF)  
CLOCK HOUR  
CLOCK MINUTE  
CALENDAR MONTH  
CALENDAR DATE  
CALENDAR YEAR  
UNITS: TEMPERATURE (ºF or ºC)  
UNITS: PRESSURE (inHg or hPa)  
You will automatically exit SET MODE if no buttons are pressed for 30 seconds.  
Enter SET MODE at any time by pressing the “SET” button.  
*DST is set to ON by default. If you live in an area that observes daylight  
saving time, DST should remain ON.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Placement for Maximum Accuracy  
AcuRite sensors are sensitive to surrounding environmental conditions. Proper  
placement of both the display unit and outdoor sensor are critical to the  
accuracy and performance of this product.  
Display Unit Placement  
Place the display unit in a dry area free of dirt and dust.  
Display unit stands upright for tabletop use.  
Outdoor Sensor Placement  
Sensor must be placed outside to observe outdoor conditions.  
Sensor is water resistant and is designed for general outdoor  
use, however, to extend its life place the sensor in an area  
protected from direct weather elements.  
Hang the sensor using the integrated hang holes or hanger, or  
by using string (not included) to hang it from a suitable location,  
like a well covered tree branch. The best location is 4 to 8 feet  
above the ground with permanent shade and plenty of fresh air  
to circulate around the sensor.  
Important Placement Guidelines  
• To ensure accurate temperature measurement, place units out of direct  
sunlight and away from any heat sources or vents.  
• Display unit and outdoor sensor must be within 165 ft (50 m) of each other.  
• To maximize wireless range, place units away from large metallic items, thick  
walls, metal surfaces, or other objects that may limit wireless communication.  
• To prevent wireless interference, place both units at least 3 ft (.9 m) away  
from electronic devices (TV, computer, microwave, radio, etc.).  
165 feet maximum  
(50 meters)  
Setup is Complete  
The sensor will now synchronize with the display unit. It may take a few  
minutes for synchronization to complete. Please refer to the troubleshooting  
section of this manual if anything appears to be functioning improperly.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
Using the Sportsman’s Forecaster  
Hunting & Fishing Activity Meter  
Don’t miss out on favorable weather and wildlife conditions! AcuRite’s Hunting  
& Fishing Activity Meter predicts wildlife activity levels by combining weather  
observations with lunar positioning data. View the fishing meter, the hunting  
meter, or automatically cycle between both meters.  
The Mode button (shown right), located on the front  
of the display, allows you to select the meter mode:  
Hunting Activity  
Meter Mode  
Fishing Activity  
Meter Mode  
Cycle between hunting  
& fishing activity meters.  
Press AND HOLD Mode  
button for 3 seconds.  
Learning Mode  
Self-Calibrating Forecasting uses a unique algorithm to analyze changes in  
pressure over a time period (called Learning Mode) to determine your altitude.  
After 14 days, the Learning Mode icon disappears from the display screen. At  
this point, the self-calibrated pressure is tuned in to your location and the unit is  
ready for superior weather prediction.  
Weather Forecast  
AcuRite’s patented Self-Calibrating Forecasting provides your personal forecast  
of weather conditions for the next 12 to 24 hours by collecting data from  
the sensor in your backyard. It generates a forecast with pinpoint accuracy -  
personalized for your exact location.  
STORMY  
& WINDY  
SNOW  
LIKELY  
SNOW / RAIN  
MIX LIKELY  
RAIN  
LIKELY  
MOSTLY  
CLOUDY  
(flashing=stormy)  
View the complete list of icons at www.AcuRite.com/acurite-icons  
Barometric Pressure  
Subtle variations in barometric pressure greatly affect the weather. This  
weather forecaster displays the current pressure, trend arrow and a pressure  
chart. The chart tracks and displays the change in pressure so you can monitor  
the rate of change over time.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Moon Phase  
Track the phases of the moon, conveyed through simple lunar phase icons:  
NEW  
WAXING  
CRESCENT  
1ST  
WAXING  
FULL  
LAST  
QUARTER  
WANING  
CRESCENT  
WANING  
GIBBOUS  
QUARTER GIBBOUS  
High & Low Records  
“Today” temperature records automatically clear daily at midnight. “Month”  
temperature records automatically clear at midnight on the last day of the  
month.  
• To manually clear the HIGH recorded values, press and HOLD the “  
button. Dashes display to confirm you have cleared the HIGH records.  
• To manually clear the LOW recorded values, press and HOLD the “  
button. Dashes display to confirm you have cleared the LOW records.  
Troubleshooting  
Problem  
Possible Solution  
If the wireless signal indicator shows no bars:  
• Relocate the display unit and/or the outdoor sensor.  
The units must be within 165 ft (50 m) of each other.  
• Make sure both units are placed at least 3 feet (.9 m)  
away from electronics that may interfere with the  
wireless communication (such as TVs, microwaves,  
computers, etc).  
• Use standard alkaline batteries (or lithium batteries in  
sensor when temperature is below -4ºF/-20ºC). Do not  
use heavy duty or rechargeable batteries. NOTE: It  
may take up to 20 minutes for display unit and sensor  
to synchronize after batteries are replaced.  
No outdoor sensor  
reception  
no bars  
• Check that the batteries are installed correctly.  
Batteries may need to be replaced.  
• Reset the display by pressing the reset button, located  
on the back of the display unit. Date and time will  
need to be entered after a reset.  
Display screen  
not working  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting  
Problem  
Possible Solution  
Flashing of the outdoor temperature is generally an  
indication of wireless interference.  
1. Bring both the sensor and display unit indoors and  
remove batteries from each.  
2. Reinstall batteries in the outdoor sensor.  
3. Reinstall batteries in the display unit.  
Outdoor  
temperature  
is flashing or  
showing dashes  
4. Let the units sit within a couple feet of each other for  
about 20 minutes to gain a strong connection.  
• Weather Forecast icon predicts conditions for the next  
12 to 24 hours, not current conditions.  
• Has Learning Mode icon disappeared from the  
display unit? Learning Mode must complete before  
forecast and pressure will be accurate.  
• Allow unit to run continuously for 33 days. Battery  
removal or resetting the display unit will restart  
Learning Mode. After 14 days, forecast should be  
fairly accurate, however Learning Mode calibrates for  
a total of 33 days.  
Inaccurate forecast  
• Make sure both the display unit and sensor are  
placed out of direct sunlight and away from any heat  
sources or vents (see page 6).  
Inaccurate  
temperature  
If your AcuRite product does not operate properly after trying  
(877) 221-1252 for assistance.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Care & Maintenance  
Display Unit Care  
Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep  
away from dust, dirt and moisture. Clean ventilation ports regularly with a  
gentle puff of air.  
Outdoor Sensor Care  
Clean with a soft damp cloth. Do not use caustic cleaners or abrasives.  
Replace Intelli-Time Clock Battery  
Intelli-Time technology is  
powered by a pre-installed  
coin-cell battery that stores  
the time and date settings.  
The battery has a shelf life of  
several years. To replace the  
Intelli-Time battery:  
Insert  
CR2032 Battery  
CR2032  
3V  
2
1. Locate the coin cell battery  
compartment door on the  
back of the display unit.  
Unscrew and remove the  
compartment cover.  
2. Insert 1 x CR2032 coin  
cell battery into the battery  
compartment, as shown.  
Install battery with “+”  
positive terminal facing  
OUT.  
Remove  
Battery Cover  
1
3. Screw in the battery cover.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications  
Outdoor: -40ºF to 158ºF; -40ºC to 70ºC  
TEMPERATURE RANGE  
165 ft / 50 m depending on home construction materials  
433 MHz  
WIRELESS RANGE  
OPERATING FREQUENCY  
POWER  
Display: 3 x AA alkaline batteries  
Sensor: 2 x AA alkaline or lithium batteries  
Outdoor Data: 31 second updates  
DATA REPORTING  
Indoor Data: 30 second updates  
FCC Information  
This device complies with part 15 of FCC rules. Operation is subject to the following two conditions:  
1- This device may NOT cause harmful interference, and  
2- This device must accept any interference received, including interference that may cause undesired operation.  
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules.  
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment  
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause  
harmful interference to radio communications. However, There is no guarantee that interference will not occur in a particular instal-  
lation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the  
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  
• Reorient or relocate the receiving antenna.  
• Increase the separation between the equipment and the receiver.  
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  
• Consult the dealer or an experienced radio/TV technician for help.  
NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment.  
Such modifications could void the user authority to operate the equipment.  
This device complies with Industry Canada licence-exempt RSS standard(s).  
Operation is subject to the following two conditions:  
(1) This device may not cause interference, and  
(2) This device must accept any interference received, including interference that may cause undesired operation of the device.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Customer Support  
AcuRite customer support is committed to providing you with best-in-  
class service. For assistance, please have the model number of this  
product available and contact us in any of the following ways:  
(877) 221-1252  
24/7 support at www.AcuRite.com  
Installation Videos  
Instruction Manuals  
Replacement Parts  
Register your Product  
Support User Forum  
Submit Feedback & Ideas  
PRODUCT MUST BE REGISTERED  
TO RECEIVE WARRANTY SERVICE  
IMPORTANT  
PRODUCT REGISTRATION  
Register online  
to receive 1 year  
warranty protection  
Register a Product  
www.AcuRite.com  
Limited One Year Warranty  
warranty will not be breached, and Chaney will give no credit  
for products it manufactures which have received normal wear  
and tear, been damaged (including by acts of nature), tampered,  
abused, improperly installed, damaged in shipping, or repaired  
or altered by others than authorized representatives of Chaney.  
At AcuRite, we proudly uphold our commitment  
to quality technology. Chaney Instrument Co.  
warrants that all products it manufactures to  
be of good material and workmanship, and to  
be free of defects when properly installed and  
operated for a period of one year from the date  
of purchase.  
The above-described warranty is expressly in lieu of all other  
warranties, express or implied, and all other warranties are  
hereby expressly disclaimed, including without limitation the  
implied warranty of merchantability and the implied warranty  
of fitness for a particular purpose. Chaney expressly disclaims  
all liability for special, consequential or incidental damages,  
whether arising in tort or by contract from any breach of this  
warranty. Some states do not allow the exclusion or limitation  
of incidental or consequential damages, so the above limitation  
or exclusion may not apply to you. Chaney further disclaims all  
liability from personal injury relating to its products to the extent  
permitted by law. By acceptance of any of Chaney’s products,  
the purchaser assumes all liability for the consequences arising  
from their use or misuse. No person, firm or corporation is  
authorized to assume for Chaney any other liability in connection  
with the sale of its products. Furthermore, no person, firm or  
corporation is authorized to modify or waive the terms of this  
paragraph, and the preceding paragraph, unless done in writing  
and signed by a duly authorized agent of Chaney. This warranty  
gives you specific legal rights, and you may also have other  
rights which vary from state to state.  
We recommend that you visit us at  
your product. However, product registration  
does not eliminate the need to retain your  
original proof of purchase in order to obtain  
warranty benefits.  
Chaney Instrument Co. warrants that all products it manufactures  
to be of good material and workmanship, and to be free of  
defects when properly installed and operated for a period of  
one year from the date of purchase. Remedy for breach of this  
warranty is limited to repair or replacement of the defective  
item(s). Any product which, under normal use and service, is  
proven to breach the warranty contained herein within ONE  
YEAR from date of sale will, upon examination by Chaney,  
and at its sole option, be repaired or replaced by Chaney.  
Transportation costs and charges for returned goods shall  
be paid for by the purchaser. Chaney hereby disclaims all  
responsibility for such transportation costs and charges. This  
For in-warranty claims: Chaney Instrument Co.  
965 Wells St., Lake Geneva, WI 53147  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Weather  
Stations  
Temperature  
& Humidity  
Weather  
Alert Radio  
Kitchen  
Thermometers  
& Timers  
Clocks  
It’s more than accurate, it’s  
AcuRite offers an extensive assortment of precision instruments,  
designed to provide you with information you can depend on to  
Plan your day with confidence.  
www.AcuRite.com  
©Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark  
of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and  
copyrights are the property of their respective owners. AcuRite uses patented  
Printed in China  
00251W INST 120213  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Bionaire Air Cleaner BAP422RC CN User Manual
Black Box Network Card ServSwitchTM User Manual
Black Decker Cordless Drill GCO182 User Manual
Blomberg Washer WNF 7300 WE20 User Manual
Braun Bathroom Aids LS 30 User Manual
Brother Fax Machine MFC 730 User Manual
Canon Webcam Model 6401 B User Manual
Cardinal Gates Safety Gate CP30 User Manual
Casio Video Game Keyboard px 330 User Manual
Cisco Systems Computer Drive WUSB54GC User Manual