Step 2  
Overview  
The Outdoor Multi-Unit Telephone Interface uses a  
900 Mhz secure digital radio link that allows secure  
conversations and gate operator control.  
The Outdoor Multi-Unit Telephone Interface  
(MUOTIU-EX) is compatible with various Liftmaster  
Wireless Products.  
Carton Inventory  
Mount to solid surface.  
Test/Program Cord  
Wiring to AC Adapter  
Outdoor Multi-Unit Telephone  
Interface (MUOTIU-EX)  
Remove bottom panel  
of the MUOTIU-EX.  
AC Adapter  
Antenna  
ACTIVE POWER  
Line IN  
Line OUT  
PWR GND  
Assembly & Installation  
Choose location near the de-mark location.  
Step 1  
Connect the Solid Black Wire to the GND Terminal  
(shown below).  
Connect the Striped Wire to the +18V Terminal  
(shown below).  
Power  
Active  
LINE  
PHONE  
TIP  
GND  
+18V  
TIP  
RING  
RING  
Screw in antenna.  
Use the supplied Test/Program Cord for programming  
and testing before completing connections to phone  
company’s de-mark box.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
MUOTIU-EX is not getting expected transmission  
range.  
PIN Number Functions  
Number  
Function  
When used in buildings with stucco or cement walls,  
the range is greatly reduced. The Repeaters can be  
used close to the building to solve this problem.  
Keep MUOTIU-EX away from trees, metal objects,  
masonry, computers, and any other “Radio Noise  
Source”. Radio devices that run on 900 Mhz also  
affect range. Turn them off and see if reception has  
improved.  
*#(00-63)#(Phone Number)# Program number  
**01*****  
**03#(00-63)#  
**07  
Erase ALL numbers  
Erase ONE number  
Activate the  
MUOTIU-EX  
Verify Call Forwarding  
Number  
**06#(00-63)#  
Keep antenna vertical.  
**#8  
*9  
Clear memory  
Activate gate  
After dialing “*9” a beep is heard, then an error  
tone.  
Check batteries in GCU.  
Canada  
NOTE: For use with version 7 and higher.  
Will not accept command after dialing “**”.  
Check the line and telephone connections.  
To enable Canadian Mode press “**13”. To disable  
Canadian Mode press “#*16”. The Canadian  
programming numbers are shown in the table below:  
Telephone does not ring when Call button is  
pressed.  
Number  
Function  
If the Active LED on MUOTIU-EX flashes after Call  
button is pressed, check telephone connections and  
verify that the phone number is correct.  
If the Active LED on MUOTIU-EX does not flash after  
the Call button is pressed, see Programming  
Accessories to ensure MUOTIU-EX is programmed  
correctly.  
##(00-63)#(Phone Number)# Program number  
#*01*****  
#*03#(00-63)#  
#*07  
Erase ALL numbers  
Erase ONE number  
Activate the  
MUOTIU-EX  
#*06#(00-63)#  
Verify Call Forwarding  
Number  
NOTE: If the channels are changed all devices in the  
network need to be erased and reprogrammed.  
#*#8  
#9  
Clear memory  
Activate gate  
There is a buzzing or failed connection when call  
is answered.  
Move MUOTIU-EX away from phone and/or  
computer. Try changing channel of MUOTIU-EX and/  
or the channel on the MUGAPLM (see Multi-Unit Gate  
Access Panel manual).  
Troubleshooting  
Dial tone is not heard after connecting to the  
MUOTIU-EX.  
Check phone connections. If it is a two-line phone  
ensure it is on Line 1.  
Only first couple of words from caller are heard.  
Lower the MUGAPLM microphone sensitivity (see  
Multi-Unit Gate Access Panel manual).  
If a dual-tone error tone is heard when trying to open  
gate, ensure MUOTIU-EX is programmed to the  
correct MUGAPLM. Check that gate operator has  
been taught to master unit as well.  
If MUOTIU-EX has already been programmed it will  
need to have memory cleared (see below).  
Memory needs to be cleared.  
Clearing MUOTIU-EX memory will not clear any  
MUOTIU-EX settings or programmed phone numbers.  
To clear memory, dial “**#8” on the telephone  
connected to the MUOTIU-EX. A beep will be heard.  
When dialing numbers a dial tone is heard.  
All numbers and symbols must be dialed within 3  
seconds of each other, otherwise the MUOTIU-EX  
times out and returns to dial tone.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
FOR TECHNICAL SUPPORT DIAL OUR TOLL FREE NUMBER:  
1-800-528-2806  
NOTICE: To comply with FCC and or Industry Canada rules (IC), adjustment or modifications of this receiver and/or transmitter are prohibited,  
except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.  
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the following two conditions: (1) this device may not  
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  
© 2008, The Chamberlain Group Inc.  
All Rights Reserved  
114A3698  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Belkin TV Video Accessories F5U109 User Manual
Black Decker Food Processor FP1445 User Manual
Blanco Indoor Furnishings 157 064 User Manual
BMW Automobile 01 41 0 158 515 User Manual
Bradford White Corp Water Heater 900kW User Manual
Bradford White Corp Water Heater LD WH6U3 1 User Manual
Briggs Stratton Portable Generator 30235 User Manual
Brookstone Electric Shaver Electric Shaver User Manual
Brother Fax Machine FAX 2480C User Manual
Chromalox Air Conditioner 8003 User Manual