Centurion Oxygen Equipment CP72SR5 User Manual

D3, D5, A5  
SLIDING GATE  
AUTOMATION  
Product Code: CP72SR5  
INSTALLATION  
MANUAL  
Latest Revision: 02.02.2005  
Document Ref.: 1010.D.01.00136_8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT  
30  
Oil Specifications:  
GRADE: 75W90  
Qty: 75ml  
31  
32  
OIL  
LEVEL  
33  
34  
35  
36  
WARNING! (D5/A5 ONLY)  
Fill with oil prior to running  
gearbox.  
For transport purposes this  
unit has been supplied with  
oil in a separate sealed  
container.  
1. Lift off the cover to the  
operator.  
2. Remove the control card  
and battery so that you  
can gain access to the  
filler plug.  
37  
38  
3. Unscrew the cap and  
pour in the oil provided  
NB. D3 is pre-filled with  
fluid grease.  
MAJOR COMPONENTS (TYPICAL D5 SHOWN)  
- COVER  
- CONTROLLER (CP80 FOR D3/D5; CP81 FOR A5)  
- MOTOR (12V DC FOR D3/D5; 220V AC FOR A5)  
- BATTERY (12V DC, 7A/H-D3/D5 ONLY) (OR PSU1/2, IF FITTED)  
- CHARGER TRANSFORMER/POWER SUPPLY (CP84E for D3/D5  
or CP83E for A5) (NOT FITTED WHEN PSU1/2 IS USED).  
- GEARBOX CASING  
- INTERNAL LIMIT SWITCH (DOSS)  
- MANUAL RELEASE THUMBWHEEL  
- LOCKABLE ACCESS DOOR  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE 1  
RUN (kgF)  
GATE MASS (kg)  
START (kgF)  
D3  
D5  
25  
60  
12  
20  
300  
500  
500  
500  
D5 Light Industrial  
16*  
22  
16*  
22  
A5  
*LIMITED BY CAPACITY OF PSU  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANTI-LIFT BRACKETS  
- Guide rollers  
must ensure that the gate is held vertically.  
39  
40  
should be <5mm to ensure  
- Fit suitable anti-lift brackets  
. The gap  
42  
the gate cannot be lifted off the motor pinion.  
- For improved safety fit additional support post  
to prevent gate from  
41  
falling over if guide rollers  
fail.  
39  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
D5  
A5  
100  
120  
100  
80  
*
81  
67  
56  
48  
60  
41  
36  
40  
20  
Pull ( kgf )  
Time (hrs)  
A5 with FAN  
120  
100  
80  
60  
40  
20  
0
0
Time (hrs)  
DUTY CYCLE CURVES  
- FOR THE WARRANTY TO BE VALID, ENSURE THAT THE DUTY CYCLE  
IS NOT EXCEEDED FOR THE PARTICULAR MOTOR BEING USED.  
* - DUTY CYCLE IS SUBJECT TO BATTERY AND CHARGER SIZE.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
6
7
2
9
11  
3
8
10  
4
RECOMMENDED INSTALLATION AND  
CABLE THICKNESS REQUIREMENTS  
- LOCAL ISOLATOR  
- MAINS SUPPLY (min 0.5mm² ‡, 2 CORE + EARTH)  
- INTERCOM AND STATUS SIGNALING TO HOUSE  
(0.2mm², *n1 + 6 CORE)  
- INTERCOM TO GATE STATION (0.2mm², #n2 CORES)  
- PILLAR LIGHTS (0.5mm², 2 CORE + EARTH)  
- RADIO RECEIVER (0.2mm², 3 CORE)  
- PEDESTRIAN KEYSWITCH (0.2mm², 2 CORE)  
- INFRA RED BEAM (0.2mm², 3 CORE)  
- FREE EXIT LOOP (1.5mm², multi stranded cable)  
- FREE EXIT CONTACT (0.2mm², 2 CORE)  
† For cable types to be used (e.g. SWA, Cabtyre, Intercom cable etc.) consult your  
municipal authority for details.  
* n1 = NUMBER OF CORES REQUIRED BY INTERCOM  
# n2 = NUMBER OF CORES REQUIRED BY INTERCOM  
‡ sufficient for motor only, increase to suit total load if pillar lights are fitted  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
MECHANICAL MOUNTING DETAILS  
Option 1 - Bolt down onto concrete plinth  
- Ensure motor does not protrude into drive-way install baseplate  
with centre line 250mm off pillar centre.  
- Position baseplate (43) with centre of single support stud (45) 105mm  
from edge of gate (46). (This dimension assumes centre line of rack (47)  
is 20mm from edge of gate).  
- Using the baseplate as a template mark and drill the 4 mounting holes  
into the concrete for the four M10 x 95 expansion studs.  
- Use two M12 plated nuts per expansion stud as spacers below the  
foundation plate.  
- Secure the baseplate to the expansion studs using one M10 washer and  
nut per expansion stud.  
43  
47  
46  
45  
105mm  
20mm  
C
L
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
M10 Nut  
M10 Washer  
Use two M12 plated  
nuts as spacers.  
M10 x 95 expansion stud  
2
5
0
m
m
C
L
Existing concrete plinth  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
43  
43  
47  
46  
45  
44  
44  
105mm  
2
5
0
m
m
20mm  
C
L
C
L
300mm  
400mm  
400mm  
MECHANICAL MOUNTING DETAILS  
Option 2 - Set into concrete plinth  
- Ensure motor does not protrude into drive-way install baseplate  
with centre line 250mm off pillar centre.  
- Fasten concrete anchors (44) to the baseplate (43) using the M10x45  
bolts provided. Ensure that the bolts are well tightened.  
- Position baseplate (43) with centre of single support stud (45) 105mm  
from edge of gate (46). (This dimension assumes centre line of rack (47)  
is 20mm from edge of gate).  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
46  
47  
43  
PROVISION FOR CABLES  
- Ensure cables 46 are fitted through base plate 43 before concreting  
in place.  
47  
- Remove knock-outs  
from gearbox to allow for cable entry.  
- Route cables in front of battery (D3/D5 motors) as shown above.  
- Seal cable entry holes with silicone sealer.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
54  
53  
54  
52  
51  
GEARBOX MOUNTING DOWN DETAILS  
- Leave at least 7mm clearance between the lower gearbox nuts  
the baseplate to allow for later adjustment.  
and  
52  
- Gearbox MUST be firmly located between top & bottom nuts and washers  
54 as shown at 51 . Use spring washer 53 to lock top nut in place.  
- Slide gearbox forwards or backwards to give ±8mm clearance between  
front of pinion and edge of gate.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
55  
±300 mm  
56  
57  
MOUNTING RACK  
- Attach steel rack to gate using 25x25x2mm angle brackets 55 . Distance  
between centerline of rack and edge of gate should be 20mm (see  
).  
56  
- For best results support rack every 300mm.  
57  
- Rack must be mounted level with a 2 - 3mm clearance  
.
USEFUL TIP  
l
Raise gearbox by an additional 3mm.  
Put gearbox into manual mode  
l
(see........on page 22)  
37  
l
Mesh rack and pinion fully and mount rack.  
Slide gate backwards and forwards  
ensuring that rack mesh is smooth and  
never tight.  
l
Drop gearbox by 3mm to create 3mm tooth  
clearance.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
59  
58  
200 - 300mm  
LEVEL  
200mm  
60  
MOUNTING RACK CONTINUED  
- A simple way of ensuring correct pitch spacing when joining steel rack is  
58  
to clamp a small offcut  
between the two pieces.  
59  
- Check that weld  
does not foul with meshing surfaces.  
60  
- If RAZ ™ rack  
is used, then start installing from the right hand side of  
the gate working towards the LHS. Use fastening screws e.g. “TEK” screws  
at least every 200mm.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
65  
IDLER  
PULLEYS  
64  
>100mm  
63  
>100mm  
62  
61  
INSTALLING CHAIN DRIVE SYSTEMS  
- Weld rear anchor plate  
pin  
onto gate such that centre line of tensioner  
61  
is in line with top of the shaft on the idler pulley  
. Allow at least  
64  
62  
100mm between idler pulleys and anchor brackets.  
63  
61  
- Align fixed anchor bracket  
as for  
.
65  
- Ensure chain direction over sprocket is as shown (see  
).  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6mm  
13mm  
<15kgF  
SETTING MECHANICAL CLUTCH (A5 ONLY)  
- Isolate MAINS POWER.  
- Remove fan from motor to expose the motor shaft (where applicable).  
Ensure fan has stopped turning.  
- Lock shaft using 13mm spanner and use 6mm allen key to adjust  
sensitivity - Clockwise to increase force.  
- Recommended maximum push force should not exceed 15kgF.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MOUNTING CONFIGURATION  
FOR STEEL RACK  
BOLT USING  
FASTENERS  
PROVIDED  
WELD  
MOUNTING  
BRACKET  
66  
A
PROVIDED TO  
STEEL RACK  
68  
m
m
0
0
5
N
A
H
T
R
E
T
A
ORIGIN MARKER  
BRACKET  
E
R
G
66  
GREATER THAN 500mm  
66  
B
66  
C
13-20mm  
68  
MOUNTING OF GATE SENSOR  
- With the gate in the CLOSED position, mount the origin marker (66) a minimum  
500mm from the origin sensor (68). (See isometric view (A) or plan view (B)  
above).Please note this distance will affect the pedestrian opening distance. For  
minimum pedestrian opening, mount the origin marker at 500mm. The  
maximum distance of the origin marker is limited by the marker having to pass  
the sensor by no less than 500mm before the gate opens fully. If a longer  
crawling distance is required, the position of the marker needs to be changed  
(see table 3 on page 30).  
- Manually slide gate OPEN until origin marker (66) is in line with the origin  
sensor (68). Ensure distance between face of marker (66) and front face of  
sensor (68) is between 13 and 20mm. (See (C) above)  
- Adjust distance by sliding the origin marker (66) along the slotted mounting  
holes until desired distance is achieved.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CP81  
CP80  
CP80 PSU1  
M1 M2 M3  
L
N
E
LIGHT COM  
17  
15  
M
M
12  
16  
16  
15  
15  
E
E
N
N
L
L
75  
L
E
L
L
N
E
13  
20  
13  
N
21  
E
76  
18  
14  
BATT  
BATT +  
-
19  
L
N
E
19  
13  
21  
17  
*
POWER WIRING (SEE PAGE 15 FOR SIGNAL WIRING)  
- 220V AC MOTOR WITH STARTING CAPACITOR  
- 220V AC, 1Ø, MAINS SUPPLY FOR CP84E / CP83E USING  
REMOVABLE CONNECTORS  
- CP83E POWER SUPPLY TRANSFORMER (A5 MODEL ONLY)  
- 220V AC PILLAR LIGHT (NOT AVAILABLE ON CP84XTE PSU)  
- 12V DC MOTOR  
- 12V DC LEAD ACID BATTERY (Amp/HOUR RATING TO SUIT)  
- CP84E CHARGER TRANSFORMER (D3/D5 MODEL)  
(OR CP84XTE WHEN USED WITH PLUG-IN TRANSFORMER)  
- LIGHTNING EARTH POINT  
- 12V DC PLUG TO CP81 CONTROLLER  
- 14.2V DC CHARGE PLUG TO CP80 CONTROLLER  
- PSU1/2 - POWER SUPPLY UNIT  
- MAINS FUSE - PSU1/2  
NOTE: External battery not necessary but if fitted then CP80 PSU1  
*
controller must be fitted.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CP80 / CP81  
NEG  
COM  
12V  
N/O  
22  
23  
NEG  
12V  
12V  
N/C  
NEG  
COM  
24  
25  
26  
27  
28  
29  
SIGNAL WIRING (CP80 AND CP81)  
- RADIO RECEIVER (OR OTHER TRIGGER e.g. INTERCOM)  
- INFRA RED BEAM TRANSMITTER  
- INFRA RED BEAM RECEIVER (N/C CONTACT)  
- FREE EXIT TRIGGER (N/O CONTACT)  
- REMOTE STATUS LED (MAX 3 IN PARALLEL)  
- PEDESTRIAN TRIGGER (N/O CONTACT)  
- HOLIDAY LOCKOUT CONTROL (N/C LATCHING CONTACT)  
- REMOTE PILLAR LIGHT CONTROL (N/O CONTACT)  
= LED INDICATORS ON P.C.B. SHOWING STATUS OF INPUT SIGNALS  
† = USE MULTI LED DRIVER CARD (CP78) FOR MORE LED’S  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
31  
34  
50  
ENL  
220V AC  
INPUT  
LNE  
220V AC OUTPUT  
49  
TO CP80/CP81  
PCB "DC IN”  
43  
48  
RECOMMENDED LIGHTNING PROTECTION  
- For optimum lightning protection ensure earth cable from charger/PSU unit  
34 is adequately earthed.  
49  
- Use ring lug  
to bond to baseplate mounting stud.  
43  
48  
- For additional protection bond baseplate  
to earth spike  
.
34  
- In event of damage to charger/PSU unit  
disconnect quick release link  
50  
and push-on connector on controller.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
2
3
4
5
END  
COMMISSIONING BLOCK DIAGRAM  
- Check correct motor direction (pg. 20)  
- Select programme mode (pg. 21)  
- Setting of gate limits (pg. 22-27)  
1
2
3
NOTE: D3/D5 LIMITS ARE SET AUTOMATICALLY.  
A5 LIMITS ARE SET MANUALLY  
- Function Selections(optional) (pg. 27-28)  
- Timer/counter settings (optional) (pg. 29-30)  
4
5
Steps 1 to 3 must be done on initial commissioning.  
Steps 4 & 5 are optional.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CP80  
12V DC  
CP81  
220V AC  
MOTOR  
M1 M2 M3  
b
a
a
c
b
TO 12V DC MOTOR  
TO 220V AC MOTOR  
SETTING MOTOR DIRECTION  
CP80  
CP81  
b
a
a
GATE CLOSES: -  
b
c
TOWARDS LEFT (ABOVE) BLACK BLUE BLUE BLACK RED  
TOWARDS RIGHT  
BLUE BLACK RED BLACK BLUE  
ENSURE THAT MOTOR WIRE COLOURS ARE AS PER TABLE ABOVE  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
2
3
L2  
L1 L2  
L1 L2  
L1  
CP80/CP81  
CP80/CP81  
CP80/CP81  
STATUS  
13.8V STATUS  
STATUS  
72  
SET  
SET  
SET  
BLACK  
RED  
69  
71  
70  
SELECTING PROGRAMME MODE  
STEP 1 - Remove power from control card:  
- for A5 remove electronics power only  
69  
70  
- for D3/D5 remove battery power  
as well as electronics  
69  
power  
.
71  
STEP 2 - Fit “SET” link  
.
STEP 3 - Reapply power (reversal of STEP 1). STATUS LED will flash 5 times  
on power up. Check that LED L2 and “SET” are ON.  
72  
LED L2  
indicates controller is in “programme mode”.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fig.1  
1/2  
1/2  
73  
Fig.2  
37  
SETTING GATE LIMITS  
37  
- Rotate manual release thumbwheel  
fully clockwise, or until clutch is  
fully dis-engaged and gate can be moved by hand.  
D3/D5 ONLY  
73  
- Slide gate approximately half way open. See  
- Re-engage gearbox.  
above (FIG. 1).  
A5 ONLY  
- Slide gate to fully closed position (FIG. 2).  
- Leave gearbox dis-engaged.  
- Skip to page 25-27 and follow START MANUAL GATE LIMITS ROUTINE.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CP80/CP81  
control card  
L2  
L1  
TEST  
STATUS  
SET  
SETTING GATE LIMITS (continued)  
NB. Ensure you follow the correct procedure!  
The procedure for setting D3/D5 and A5 motors is DIFFERENT.  
The A5 limits have to be set manually (see page 25 and 26), while  
the D3/D5 motors set their limits automatically (see page 21 to 23).  
D3/D5 ONLY (PAGE 23, 24, 25)  
- Press the TEST pushbutton while monitoring LED L1.  
- When L1 flashes once, release TEST pushbutton. L2 will go out,  
L1 will continue to flash once per second. Controller is now in MENU 1  
which sets gate limits.  
NB. Understand the procedure detailed on page 24 before continuing.  
The controller is about to perform the fully automatic setup routine.  
CP80/CP81  
control card  
L2  
L1  
TEST  
STATUS  
SET  
START AUTOMATED GATE LIMITS ROUTINE  
- Press TEST pushbutton until STATUS LED illuminates.  
- AUTOMATIC set up routine (described on page 24) starts as soon as TEST  
button is released.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D3/D5 MOTOR AUTOMATIC SET-UP  
1
1- Gate starts at “crawl” speed to open  
gate.  
NB. If gate closes, remove power and  
reverse motor wires (see page 20)  
2
3
4
2- Gate hits “open” end stop and reverses  
direction running at crawl speed.  
3 - Gate hits “closed” end stop and  
reverses direction running at “FULL”  
speed until the marker, then at  
CRAWL speed to end.  
4 - Gate hits “open” end stop and  
reverses but now runs at “FULL”  
speed.  
5
6
5 - As gate sensor passes the motor, the  
speed reduces to CRAWL. Gate hits  
“closed” end stops and reverses  
at FULL SPEED.  
6 - Gate stops at “pedestrian” (PED)  
position. If required, widen PED  
opening by pulsing PED input.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TURBO MODE: If desired the set up time can be shortened by manually  
overriding the automatic “crawl”speed in steps 1, 2, 3 shown on page 24.  
This is done by pressing and holding the TEST button. The speed increases  
to FULL speed while the button is depressed.  
NB. Do not run the gate into the end stops at full speed.  
74  
CP80  
control card  
CP80  
control card  
L2  
L1  
L1  
L2  
TEST  
TEST  
STATUS  
STATUS  
SET  
SET  
EXIT GATE LIMITS ROUTINE (D3/D5 ONLY)  
- After the gate stops at the required pedestrian position (see step 6 on  
page 24) ie either at the automatic minimum or the manually over-ridden  
position, press the TEST button for a moment and release.  
- L2 will illuminate when TEST button is released.  
74  
- Remove SET link and position as shown above,  
unless proceeding to other menus.  
, to exit programming  
NB. If automatic routine does not complete (indicated by STATUS flashing  
5 times & L2 illuminating) then it may be necessary to set collision  
sensitivity to MED or LOW (see page 28)  
START MANUAL GATE LIMITS ROUTINE  
A5 ONLY (PAGE 26 & 27)  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A5 MOTOR MANUAL SET-UP  
STEP 1 ALIGN ORIGIN SWITCH  
- Start with gate fully closed.  
- Push gate open (origin marker must have  
moved well past origin switch).  
- Push gate closed again.  
STEP 2 - ENSURE PCB IS IN PROGRAMME  
MODE (refer procedure page 21)  
STEP 3 - SET LIMITS  
- Press TEST pushbutton until LED L1 flashes  
once and release.  
- L1 will continue to flash once and L2 will  
go out.  
- Press TEST pushbutton until STATUS LED  
comes ON and release (check that L1, L2 &  
STATUS are OFF)  
STEP 4  
- Push gate to fully “OPEN” position and do not  
allow gate to reverse.  
- Press TEST pushbutton until STATUS LED  
comes ON and release.  
STEP 5  
- Push gate to fully “CLOSED” position hard  
up against endstop and do not allow gate  
to reverse.  
- Press TEST pushbutton until STATUS LED  
comes ON and release.  
STEP 6  
- Push gate to “PEDESTRIAN” open position.  
- Press TEST pushbutton until STATUS LED  
comes ON and release. If STATUS LED  
does not come ON, increase pedestrian  
opening until it does.  
“PED”  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
74  
CP81  
control card  
CP81  
control card  
L2  
L1  
L1  
L2  
TEST  
TEST  
STATUS  
STATUS  
SET  
SET  
EXIT GATE LIMITS ROUTINE (A5 ONLY)  
If the gate limits described on page 26 are successfully completed,  
then LED L2 will be ON.  
74  
- Position SET link as shown above  
proceeding to other menus.  
to exit programming unless  
FUNCTIONS SELECT  
Several different functions can be programmed. The procedure which is similar for all  
functions is described below in conjunction with TABLE 2 on page 28  
STEP 1 - Ensure controller is in Programme Mode (see page 21).  
STEP 2 - Press and hold the TEST pushbutton while monitoring LED L1.  
STEP3- L1 will flash once then go off, twice in short succession then go off, 3 times  
then go off, etc. The number of flashes represents the menu number.  
STEP4- Release TEST button when the required main menu (see Table 2, page 28) is  
selected.  
STEP5- To select the sub-division of the main menu (see RHS of Table 2), press and  
hold the TEST pushbutton, while monitoring the STATUS LED to count  
flashes. The number of times the STATUS LED flashes represents the sub  
menu number.  
STEP6- Release TEST pushbutton when the required subdivision is selected. L2 will  
come ON to indicate that the controller is back in PROGRAMME MODE and  
another FUNCTION or TIMER (refer to procedure on page 29) can be  
programmed.  
STEP 7 - Remove SET link when all programming is complete.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE 2  
MAIN  
MENU  
SUB DIVISION  
OF MAIN MENU  
No of times  
L1 flashes  
No of times  
STATUS must flash  
1
2
ON  
2
4
AUTO CLOSE  
MODE  
OFF  
1
2
3
4
STANDARD  
CONDOMINIUM  
PIRAC  
REVERSING  
COLLISION  
SENSITIVITY  
7
1
2
3
HIGH  
MEDIUM  
LOW  
POSITIVE  
CLOSE MODE  
1
2
ON  
9
OFF  
10  
1
2
3
4
MODE1  
MODE 2  
MODE 3  
OFF  
PREFLASHING*  
FACTORY DEFAULTS HIGHLIGHTED  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
*The PREFLASHING MODES mentioned on page 28 are described below:  
MODE 1 - COURTESY LIGHT PREFLASHES AT 1 HZ, THEN ACTS AS  
COURTESY LIGHT.  
MODE 2 - COURTESY LIGHT FLASHES AT 1 HZ FOR PREFLASH TIME  
AND THEN FLASHES IN SYNCHRONISM WITH THE STATUS LED  
WHILE THE MOTOR RUNS.  
MODE 3 - COURTESY LIGHT ON CONTINUOUSLY FOR PREFLASH TIME  
AND MOTOR RUN TIME ONLY.  
TIMER and COUNTER SETTING  
Various timers and counters can be programmed. The procedure is described  
below in conjunction with Table 3, page 30.  
STEP 1 - Ensure controller is in Programme Mode (seepage 21).  
STEP2- Press and hold the TEST pushbutton while monitoring LED L1.  
STEP3- L1 will flash once then go off, twice in short succession then go off, 3  
times then go off, etc.  
STEP4- Release TEST pushbutton when the desired MAIN MENU item in Table  
3isrequired.  
STEP5- To select required time (or count) hold TEST pushbutton while  
monitoring STATUS LED. After a short time STATUS will flash  
continuously and regularly. Each flash represents a unit of measure  
(i.e. time, distance or count).  
Release TEST pushbutton when the required subdivision is selected.  
L2 will come ON to indicate that the controller is back in PROGRAMME  
MODE and another TIMER or FUNCTION (refer to procedure on page  
27)canbeprogrammed.  
STEP6- RemoveSETlinkwhenallprogrammingis complete.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE 3  
MAIN  
MENU  
UNIT OF  
MEASURE  
Each flash  
of STATUS  
represents  
No of times  
L1 flashes  
FACTORY  
DEFAULTS  
3
5
NORMAL AUTOCLOSE  
PEDESTRIAN AUTOCLOSE  
COURTESY LIGHT  
1 SEC  
1 SEC  
15 SEC  
5 SEC  
6
10 SEC  
1 SEC  
12x10 SEC  
3 SEC  
8
AUTOCLOSE OVERRIDE  
PREFLASH TIME  
11  
12  
13  
13  
1 SEC  
5 SEC  
COLLISION COUNTER  
CRAWL DISTANCE (D3/D5)  
COAST MODE (A5)  
1 COUNT  
350 MM †  
10 MM  
4 COUNTS  
1x350mm  
30mm  
† THE CRAWL DISTANCE IS A LENGTH OF TRAVEL WHICH ALLOWS  
THE GATE TO SLOW DOWN BEFORE REACHING THE END STOP. FOR  
HEAVIER GATES WITH LESS FRICTION, THE CRAWL DISTANCE MAY  
HAVE TO BE INCREASED. WHEN INCREASING THE CRAWL  
DISTANCE, THE POSITION OF THE ORIGIN MARKER (ITEM 66 PAGE  
15) MUST BE MOVED.  
CRAWL STATUS FLASH  
DISTANCE  
DISTANCE BETWEEN  
MARKER AND PINION  
COUNT  
DEFAULT  
350mm  
1
500mm  
750mm  
1100mm  
700mm  
2
3
1050mm  
TURBO MODE: TO SPEED UP THE COUNTING WHILE SELECTING MAIN  
MENU ITEMS TEMPORARILY CONNECT “PED” TERMINAL TO “COM”  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PROCEDURE TO PROGRAMME CONTROLLER  
BACK TO FACTORY SETTINGS  
1. REMOVEPOWER(POWERSUPPLYANDBATTERYIFD3or D5).  
2. FITTHE"SET"LINK.  
3. CONNECT"PED"AND"FRX"TO"COM".  
4. RECONNECTPOWER. L1AND L2WILLILLUMINATE.  
5. REMOVETHEPOWER(BATTERYANDPOWERSUPPLY).  
6. REMOVETHE"SET"LINKANDDISCONNECT"PED"AND"FRX"FROM"COM".  
7. THE CARD IS NOW PROGRAMMED TO DEFAULT SETTINGS AS SHOWN IN  
TABLES 2 (see page 28) AND TABLE 3 (see page 30) (GATE END POINTS ARE  
NOT AFFECTED).  
FAULT FINDERS GUIDE D3 / D5 OPERATORS  
REF: CP157  
EFFECTIVE: 19/09/2001  
SUPERCEDE: 29/11/2000  
SOMETYPICALFAULTS  
1. GATERUNSASHORTDISTANCEANDSTOPS.  
1.1 Batterylowcondition(Statusflashing3times)  
1.1.1 Oldbattery  
1.1.2 Checkbatterycharger  
1.1.2.1 Chargevoltage(13.8V nobatteryconnected)  
1.1.2.2 Chargerate(Checkrecoveryrateofcharger)  
1.1.3 Checkdutycycleofsystem(batterycapacitysufficient)  
1.1.4 Checkconditionofbatteryleadsandconnectors.  
1.2 Multiplecollisioncondition(Statusflashing4times)  
1.2.1 Adjustcollisionsensitivity(hightomediumortolow)  
1.2.2 Checkforsomethingphysicallyobstructingthemovementofgate  
1.2.2.1 Rackpressingdownontopinion  
1.2.2.2 Badrackjoints  
1.2.2.3 Seizedorbadlyrunningwheels  
1.2.2.4 Topguiderollersrestrictingthegate  
1.2.2.5 Dirtonrail  
1.2.2.6 Physicaldamagetotherail  
1.2.2.7 Wheelcatchingsideofpinion  
1.2.2.8 Gatehittingendstop  
1.2.3 DOSSfeedbackproblem  
1.2.3.1 DirtinsidetheDOSS  
1.2.3.2 PoorconnectionbetweentheDOSSandthecontroller(checkcableandconnector)  
1.2.3.3 Dosscablefittedbacktofront  
1.2.3.4 Dossnotbeingdrivenduetomissingcouplingorfaultybeveldrive.  
1.2.3.5 FaultyDOSScontroller  
1.2.4 Faultymotorcircuit  
1.2.4.1 Motorfuseholdermakingintermittentcontact.  
1.3 Spurioustrigger  
1.4 Faultycontroller  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. GATE DOES NOT RUN BUT THE RELAYS ENERGISE WHEN THE UNIT IS ACTIVATED.  
2.1 Faultymotorcircuit  
2.1.1 Faultymotorrelay/FET  
2.1.2 Motorfuseblown(replacewith16/20Aslowblow5x20mm)  
2.1.3 Fuseholdermakingbadcontact.  
2.1.4 Wornmotorbrushes  
2.1.5 Loosemotorwire  
2.1.6 Faultycontroller  
3. GATEOPENSONITSOWN.  
3.1 Permanent trigger input  
3.1.1 Check for latched Rx or latched house pushbutton  
3.2 Intermittent fault on pushbutton line (underground joint with moisture build-up)  
3.3 Outside transmitter with the same code (typically only possible with compatible remotes QD black / TSM etc))  
3.4 Faulty Rx  
4. INTERMITTENT AUTO-CLOSE.  
4.1 LatchingRxoverridesauto-close  
4.2 Longpulseontriggerinputoverridesauto-close(checkpulsetimeofintercomgaterelease)  
4.3 Faultyinfraredbeaminput  
4.4 Faultycontroller  
5. GATE DOES NOT RECOGNISE ITS LIMITS.  
5.1 Magnetincorrectlymounted(Checkpage13ofinstallationmanual)  
5.2 Faultymagneticswitch  
5.3 CheckconnectionbetweenswitchandcontrollerviaDOSS.  
5.4 Faultycontroller  
6. GATEDOESNOTTRIGGERATALL. (USINGTESTPUSHBUTTON)  
6.1 LCKinputactivated(CheckstateofLCK)  
6.2 LatchedinputonTRGorFRXinput  
6.3 IRBinputactivated  
6.4 Faultycontroller  
7. GATE OPENS TO PEDESTRIAN AND CLOSES.  
7.1 Faulty key switch  
7.2 Faulty wiring on pedestrian input  
8. GATE STARTS CLOSING BUT STOPS AND RE-OPENS.  
8.1 Intermittent IRB trigger (Check alignment and that the supply voltage for beams is compatible with the operator.)  
8.2 Collision sensitivity set too sensitive  
8.3 Spurious signal on FRX (if used) or TRG if in Condo / Pirac / Reverse mode  
WHILE COMMISSIONING (automatic Setup Routine)  
9. GATE OPENS TO THE FULLY OPEN POSITION AND DOES NOT RETURN  
9.1 Check the battery. (battery voltage should stay above 11.0v while gate is running).  
10. GATEDOESSHORTOPENANDCLOSECYCLES(L2COMESONAGAIN  
10.1 Poor connection between the DOSS and the controller (check cable and connector).  
10.2 DOSS not being driven due to missing coupling.  
10.3 Adjust collision sensitivity (high to medium or to low).  
11. GATE DOES NOT RUN BUT THE RELAYS ENERGISE WHEN THE UNIT IS ACTIVATED  
11.1 Checkmotorwiresaresecurelyterminated.  
11.2 Checkmotorfuse(replacewith16/20Aslowblow5x20mm)  
11.3 Checkbatteryconnectionsareleads.  
11.4 Checkthatbatteryisnotflat.  
12. THE OPERATOR COMPLETES SETUP ROUTINE CORRECTLY. HOWEVER WHEN ACTIVATED AFTERWARDS,  
DRIVES AT FULL SPEED INTO MECHANICAL END STOP.  
12.1 Check that origin marker (magnet) is correctly positioned for the “Crawl Distance” selected (main menu item 13). If  
indoubtrestorecontrollerfactorydefaultsettings. RefertotheInstallationManual, Table3fortableofdistances.  
12.2 Onanupgradedsystem, ensurethatcontrollerhasbeenrestoredbacktoFactorydefaultsettings  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CENTURION  
THE AUTOMATIC CHOICE  
CENTURION SYSTEMS (PTY) LTD HEAD OFFICE:  
TEL: +27 (0)11 699-2400, FAX: +27 (0)11 704-3412 or 462-6669  
148 EPSOM AVENUE, NORTH RIDING  
P.O. BOX 506, CRAMERVIEW, 2060  
SOUTH AFRICA  
FOR TECHNICAL SUPPORT CONTACT:  
SOUTH AFRICA  
EAST RAND. . . . . . . . . . . . . . . (011) 397-6401  
DURBAN . . . . . . . . . . . . . . . . . (031) 701-9583  
NELSPRUIT . . . . . . . . . . . . . . . (013) 752-8074/5  
PRETORIA . . . . . . . . . . . . . . . . (012) 362-8819/8893  
CAPE TOWN . . . . . . . . . . . . . . (021) 447-1295  
PORT ELIZABETH. . . . . . . . . . . (041) 581-6994/5  
EAST LONDON . . . . . . . . . . . . . . (043) 743-4923  
BLOEMFONTEIN . . . . . . . . . . . . . (051) 448-1714  
KIMBERLEY . . . . . . . . . . . . . . . . . (053) 832-3231  
VEREENIGING . . . . . . . . . . . . . . . (016) 422-5667  
AFRICA  
ECHO-LINE, NAMIBIA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tel: (61) 220-8309  
MOLECULAR CONSULTANTS, NIGERIA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tel: 803-3123182  
SECURITY DISTRIBUTORS, ZIMBABWE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tel: (4) 795-873  
SEKANYOLYA TIMBER WORKS, UGANDA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tel: (41) 231-40  
EUROPE  
AUTOMATISME BATIMENT, FRANCE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tel: (1) 697-93120  
CROWN AXXESS LTD U.K. UNITED KINGDOM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tel: (1483) 450-011  
NESTOR, BELGIUM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tel: (9) 380-4020  
NORTH AMERICA  
BILLY GATES, CANADA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tel: (250) 334-1553  
AUSTRALASIA  
ABA GATES, WESTERN AUSTRALIA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tel: (8) 933-03061  
DOMINATOR SYSTEMS, NEW ZEALAND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tel: (3) 384-5145  
ICBT, VICTORIA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tel: (3) 933-54213  
ROTECH, QUEENSLAND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tel: (7) 326-47330  
SA GATES, SOUTHERN AUSTRALIA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tel: (8) 826-64235  
SECURITE DU PACIFIQUE, NEW CALEDONIA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tel: 283-760  
INDIAN OCEAN  
SECULOGIX LTD, MAURITIUS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tel: 467-8509  
SECURITE AUTOMATISMES REUNION, REUNION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tel: 280-368  
ASIA & PACIFIC  
VAST VIDEO, MALAYSIA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tel: (3) 214-34931  
BLT ASSOCIATES, THAILAND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tel: (2) 691-6793  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Belkin Switch F1DJ102P B User Manual
BenQ Computer Monitor E2000W User Manual
Blackberry Cell Phone STL100 3 User Manual
Blanco Indoor Furnishings 501 113 12 User Manual
BOB Stroller OMS05A User Manual
Bryant Boiler 39006DP4 A User Manual
Canon Camera Lens EF85MM F User Manual
Casio Clock DQS 20 User Manual
CFM Corporation Indoor Fireplace UVDR36C User Manual
Chamberlain Garage Door Opener 1345C 1 3HP User Manual