Introduction  
Congratulations on the purchase of your Cecilware Counter Top Fryer. Please take time to carefully  
read through this manual to ensure the machine is operated and maintained properly. This will enable  
the best possible performance from this product for many years.  
Cecilware will not accept liability for the following if:  
*The instructions in this manual have not been followed correctly.  
*Non-authorized personnel have tampered with the machine.  
*Non-original spare parts are used.  
*The machine has not been handled and cleaned correctly.  
*There is any use damage to the unit.  
Packaging  
Cecilware prides itself on quality and service, ensuring that at the time of packing, all products are  
supplied fully functional and free of damage.  
Provided in this package are the following:  
* Fryer (selected model)  
* Basket (s)  
* Manual  
Should you find any damage as a result of freight, please contact your Cecilware dealer immediately.  
Installation  
Remove the Cecilware fryer from the packaging; be certain all protective plastics and residues are  
thoroughly cleaned from its surface.  
Place the Cecilware fryer on a firm, level surface.  
International standards and regulations should be consulted in order to abide by standards set in  
relation to positioning, spacing and ventilation. Oils used in these units are very dangerous. Take care  
when in use to avoid oil spilling on to open flames or mixing with other liquids, such as water, to avoid  
harmful damage.  
Important Note:  
Caution:  
All double pot Fryers has two power supply cords. Each Fryer pot is independently controlled. Connect  
each plug to a receptacle that is connected to an individual branch circuit. Unplug both cords before  
installing, cleaning, moving, or servicing this appliance  
Do not position and operate near combustible materials/flammable objects.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Note that there are 6 parts to the fryer:  
* Fryer Body  
* Oil pan  
* Element and control box  
* Element guard  
* Basket  
* Lid  
Place the oil pan into the fryer body; then place the element and control box into the pan. Be sure to clip  
the rear of the control box to the fryer body. Place the guard over the element at the bottom of the pan.  
The fryer can now be filled with the appropriate cooking oil.  
Please consult the specification chart in this manual (page 10) for the correct power supply for your  
model fryer. Supply the appropriate power, and connect to power supply. Your fryer is now ready to  
operate.  
Operation  
Once the fryer has been installed correctly, please consult the specification chart (page 10) for the  
required volume of cooking oil.  
Turn the thermostat dial towards the “ON” position; the amber light will activate to confirm, and adjust  
the dial to the required setting.  
Allow time for oil temperature to reach the required setting; while oil is heating the red light will activate;  
once the oil has reaches the required temperate, the red light will switch off. As the oil fluctuates in  
temperature, the thermostat will operate to maintain set temperature. The light will continue to indicate  
when the fryer is heating or has reached the required temperature.  
A temperature setting of between 325º F and 358º F will be sufficient for general cooking. This could  
vary for particular food types or individual requirements.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cleaning, Care and Maintenance  
Switch off the power and disconnect from the power source.  
The fryer should be cleaned after each day’s operation, however it may require to be cleaned more  
often, depending on the volume of production.  
The fryer must be left to cool before cleaning. Empty oil from the pan. If the oil is to be reused, it is  
recommended that it be filtered with the Cecilware Frysaver® Filtration System to ensure longer yield  
and a better quality in the cooked product. Note: the 15 lb. fryer is fitted with a drain valve.  
Once the oil has been emptied from the fryer, the control box can be tilted back to remove the pan from  
the body. The pan can be washed using warm soapy water.  
The main body can also be washed in warm soapy water, but be sure to unclip the control box and  
element first. The control box cannot be immersed in water; however, the control box can be wiped  
down with a damp cloth. Warm soapy water is recommended for cleaning. Prolonged use of cleaning  
agents can damage stainless steel.  
Safety  
*The Cecilware fryer does not contain any user-friendly parts. A Cecilware Recommended Qualified  
Service Technician should carry out repairs if necessary. Do not remove any components or service  
panels on this product.  
*Switch off power to and disconnect from the main power source while cleaning.  
Ensure oil levels are maintained above the minimum indicated level in the fryer. Failing to maintain the  
required level may result in fire.  
Ensure oil is changed regularly. Used oil breaks down after use and can result in fire, as its flash point is  
reduced, and it is more prone to surge boiling.  
Note: products containing humidity/moisture will cause surge boiling when placed in hot oil.  
The basin should remain uncovered during frying.  
Hot oil causes serious damage to skin. Avoid skin contact with hot oil.  
Do not immerse unit in water or use water jets to clean.  
If the power cord is damaged, it must be replaced by a Cecilware Service Agent or Recommended  
Qualified Service Technician in order to avoid a hazard.  
Important Note:  
Caution:  
All double pot Fryers has two power supply cords. Each Fryer pot is independently controlled. Connect  
each plug to a receptacle that is connected to an individual branch circuit. Unplug both cords before  
installing, cleaning, moving, or servicing this appliance.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Trouble Shooting  
If your Cecilware Fryer does not operate, please check the following before placing a service call.  
Top Fryer  
Problem  
EL-6, EL-15, EL-25, EL-2x6, EL-2x15  
Remedy  
Cause  
1. Mains power supply  
2. Element/ control unit not  
correctly located  
1. Check mains power supply  
2. Follow the steps on page 2 to  
correctly locate  
3. Fuse in the plug has  
blown  
3. Replace the fuse in the plug with  
correctly rated fuse  
4. Plug and lead are  
damaged  
4. Call service agent or qualified  
technician  
Oil not heating.  
Indicator light is off  
5. Call service agent or qualified  
technician  
5. Internal wiring fault  
6. Remove reset button cover (A) press  
button (B) to reset. See Diagram  
for Thermal Cut Out Reset below.  
If problem persists call service agent  
or qualified technician  
6. Thermal cut-out has  
activated  
Oil is heating &  
Indicator light is on  
Indicator light is  
1. Thermostat or heating  
element has failed  
1. Call service agent or qualified  
technician  
1. Call service agent or qualified  
technician  
1. Faulty pilot light  
not  
on  
but  
is  
appliance  
2. Oil has reached the set  
temperature  
2. Use fryer normally  
operating normally  
Please ensure:  
* There is correct power supply.  
* The machine is plugged in correctly and power is switched on.  
* The thermostat dial has been turned on.  
Note all Cecilware products are tested prior to packaging.  
DiagramThermal Cut Out Reset  
B
A
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Compliance  
Cecilware products have undergone strict product testing in order to comply with regulatory standards  
and specifications set by international, independent, and federal authorities.  
As testimony to such compliance Cecilware products carry the following marks/symbols:  
Electrical Diagram  
120/240V  
on/off  
switch  
micro-switch  
hi-limit  
thermostat  
pilot light  
heating  
element  
The above circuit diagram has been provided to assist qualified technicians. Cecilware agents or  
Recommended Qualified Service Technicians should carry out repairs if needed. Do not remove any  
components or service panels on this product.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Explosion View  
EL – 6  
1
3
6
7
4
2
5
20  
19  
8
9
18  
10  
11  
12  
13  
14  
15  
16  
17  
EL – 15/EL –25  
1
2
3
4
7
6
5
20  
19  
18  
8
9
10  
11  
17  
12  
13  
14  
15  
16  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
EL – 2 x6  
1
3
6
4
7
2
5
20  
19  
18  
8
9
10  
11  
12  
13  
14  
17  
15  
16  
EL – 2 x15/EL – 2 x25  
1
2
3
4
6
5
20  
19  
7
8
18  
9
10  
11  
17  
13  
12  
14  
15  
16  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Spare Parts List  
EL - 15 120v  
EL – 25 240v  
EL -2x15 120v  
EL-2x25 240v  
EL -6  
EL – 2 x 6  
Qty  
Qty  
Qty  
Qty  
NO  
1
Description  
Part No  
Part No  
08049  
Part No  
Part No  
Optional Fry Tank Cover  
Basket  
1
08049  
08050  
08025  
08026  
08027  
NA  
2
2
1
2
1
1
1
1
1
1
1
1
08020  
08021  
08050  
08026  
08027  
NA  
2
4
2
2
2
2
2
2
2
2
08020  
08021  
08025  
08026  
08027  
NA  
2
3
4
5
6
1
1
08050  
08025  
08026  
08027  
NA  
Hi – Limit  
2
Thermostat Dial  
Thermostat  
1
2
1
2
Back Plate  
1
2
Cord & Plug – 120 V  
Cord & Plug – 240 V  
Pilot Light – 120 V  
Pilot Light – 240 V  
1
08055  
NA  
2
08055  
NA  
08055  
08047  
08032  
08067  
08055  
08047  
08032  
08067  
7
8
NA  
1
NA  
2
08032  
NA  
08032  
NA  
NA  
NA  
9
Stuffing Box  
2
1
1
NA  
NA  
4
2
2
NA  
NA  
2
1
1
NA  
NA  
4
2
2
NA  
NA  
10  
Element Cover  
Heating Element – 120 V  
08051  
08051  
08034  
08034  
11  
Heating Element – 240 V  
Micro Switch  
NA  
1
NA  
08029  
08030  
08052  
NA  
NA  
2
NA  
08029  
08030  
08052  
NA  
1
1
2
1
1
4
2
2
2
1
1
1
08046  
08029  
08030  
08022  
NA  
2
2
4
2
1
4
4
4
4
2
2
2
08046  
08029  
08030  
08022  
NA  
12  
13  
14  
15  
16  
Bulb Clamp 2  
2
4
Fry Tank  
1
2
Main Body  
1
1
Feet  
4
08031  
08053  
NA  
4
08031  
08053  
NA  
08031  
08023  
08053  
08033  
NA  
08031  
08023  
08053  
08033  
NA  
Tube Clamp – 120 V  
Tube Clamp – 240 V  
Bulb Clamp 1  
2
4
17  
NA  
2
NA  
4
18  
19  
08033  
NA  
08033  
NA  
Electrical Head  
On/Off Switch 120 V  
On/Off Switch – 240 V  
1
2
1
08054  
NA  
2
08054  
NA  
08054  
08024  
08054  
08024  
20  
NA  
NA  
*NA = not available except by special order.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications  
FAT  
DIMENSIONS  
WxDxH)  
MODEL  
DESCRIPTION  
ELECTRICAL  
CAPACITY  
EL-6  
6 lbs.  
7 ½x17½x12 ¾”  
11x17½x15 ¾”  
120V, 1.8KW, 15A  
240V, 3.2KW, 15A  
SINGLE TANK  
EL-15  
15 lbs.  
EL-25  
15 lbs.  
11x17½x15 ¾”  
EL-2x6  
EL-2x15  
EL-2x25  
(2x) 6 lbs.  
(2x)15 lbs.  
(2x)15 lbs.  
14½x17½x12 ¾”  
21 ¾x17½ x15 ¾”  
21 ¾x17½x15 ¾”  
120V,  
(2x)1.8KW,  
(2x)3.2KW,  
(2x)15A  
TWIN TANK  
240V,  
(2x)15A  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CECILWARE CORPORATION  
43-05 20th AVENUE, LONG ISLAND CITY, NEW YORK 11105-1295 ■  
718-932-1414  
FAX 718-932-7860  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  

BenQ Computer Monitor FP73E User Manual
Blaupunkt Car Stereo System RD 104 User Manual
BMW Automobile K 1300 GT User Manual
Cables to Go Network Cables 39998 User Manual
Casio Digital Camera EX ZR10 User Manual
Casio Radio LK120 User Manual
Casio Watch MA1212 EA User Manual
Cateye Bicycle Accessories CC CD200N User Manual
Chicago Electric Sander 66891 User Manual
Chromalox Thermostat PK405 18 User Manual