MA0809-EA
HS-70W
LAP/SPLIT TIMES
CHART
ENGLISH
START
1ST LAP
STOP
RESET
2ND LAP
3RD LAP
Time Display
Stopwatch Display
0
(a)
(a + b) (a + b + c)
(t)
a
b
c
Day of the week
(
)
a
1ST SPLIT
Lap counter
Split time
(
)
2ND SPLIT a+b
3RD SPLIT a+b+c
(
)
Year
BUTTON
Month
Day
Lap time
OPERATION
PM
Total
elapsed time
Second
Minute
DISPLAY
Hour
Hours
Seconds
Minutes
1/1000th of a second
MULTIPLE FINISHING TIMES
Example : To record the times of 100 different runners.
Timekeeping Mode
Stopwatch Mode
Recall Mode
START
1ST
RUNNER
FINISHES
2ND
RUNNER
FINISHES
99TH
RUNNER
FINISHES
100TH
RUNNER
FINISHES
RESET
Press
.
Press
.
CHART
• A sticker is affixed to the glass of this stopwatch when you purchase it. Be sure to remove the sticker before using
the stopwatch.
BUTTON
OPERATION
• Depending on its model, the configuration of your stopwatch may differ somewhat from that shown in the
illustration.
Difference between current finisher
and previous finisher
OPERATING PRECAUTIONS
• A battery is installed at the factory. Have it replaced by a CASIO distributor at the first sign of low power (dim
DISPLAY
display).
• Do not use or store this stopwatch in areas exposed to temperature extremes, strong magnetism, strong
vibration, or strong impact.
• Heat can shorten battery life and cause malfunction. Keep the stopwatch away from heaters and direct sunlight
when using it.
Finishing position
• Never try to take the stopwatch apart. Doing so can cause malfunction.
• To clean the stopwatch, use a soft, dry cloth or a cloth moistened in a solution of water and a mild neutral
detergent. Wring out all excess moisture from the cloth. Never use thinner, benzene, alcohol or other similar
agents.
USING THE RECALL MODE
You can use the recall mode to view data in stopwatch memory.
• Be sure to keep all user documentation handy for future reference.
• There is enough memory to store a total of up to 200 records, divided between two record groups of 100 each. If
you record 100 times, the 100th time will not be stored in memory until you reset the stopwatch to all zeros.
• Starting a new stopwatch elapsed time operation will cause the older of the two record groups to be deleted
automatically in order to make room for a new group of records.
• There is also a FAST LAP record that displays the fastest lap from among all of the lap times currently in memory.
• Record 1 (the newest record) will always be displayed first whenever you press the R button to switch from the
Stopwatch Mode to the Recall Mode.
CASIO COMPUTER CO., LTD. assumes no responsibility for any loss, or any claims by third parties that may
arise through the use of this stopwatch.
GENERAL GUIDE
C button .... Starts and stops timing.
B button .... Toggles between the current time and stopwatch screens.
A button ..... Performs lap/split and reset operation (stopwatch beeps).
R button ..... Recalls lap/split time records and total elapsed time.
•
In the Recall Mode, each press of the B button will toggle the display between record group 1 and record group 2.
• Lap time records in memory can be recalled while an elapsed time operation is in progress or stopped.
• Memory records are cleared whenever a new Stopwatch Mode elapsed time operation is stared by pressing the
C button after pressing the A button to reset the stopwatch to all zeros.
Holding down the
or
button scrolls at high speed.
1ST SPLIT
SPLIT TIME AND LAP TIME
2ND SPLIT
2ND LAP
3RD SPLIT
3RD LAP
Split time (SPLIT) is the time
elapsed from the start to a
specific point.
START
START
1ST LAP
Lap time (LAP) is the time
elapsed from one point to another
or for one lap around a track.
SETTING THE CURRENT TIME AND DATE
1. In the Timekeeping Mode, hold down R for about two seconds.
MUTE
2. Press C on a time signal to correct the seconds.
3. Flashing setting can be changed. Press B to move the flashing.
USING THE STOPWATCH
The stopwatch beeps to signal C and A button operations.
SECONDS
HOUR
DAY
MINUTES
MONTH
YEAR
Working range
The total elapsed time and split time display is limited to 9 hours 59 minutes 59.999 seconds. Lap time display is
limited to 59 minutes 59.999 seconds.
4. Use C (+) and A (–) to change the flashing setting.
• Holding down the C or A button scrolls at high speed.
5. Press R to exit the setting mode.
Thereafter it will be reset and started again. The lap counter starts from 1 to 99 and repeats from 0.
While the stopwatch is reset to all zeros, holding down the A button will toggle the lower display area between
display of lap time and split time.
* Year digits can be set up to the year 2099.
• 100 (indicating the number of laps) will flash on the display when memory is full (100 lap times in the current
group).
12/24-hour Timekeeping
In the Timekeeping Mode, press C to toggle between 12-hour and 24-hour
NORMAL TIME
timekeeping.
START
0
STOP
(a)
RESET
Beeper On/Off
In the Timekeeping Mode, hold down the A button for about two seconds to toggle the beeper on or off.
CHART
a
Auto Return
The stopwatch returns to the Timekeeping Mode if left unused for a few minutes.
BUTTON
OPERATION
CARE OF YOUR STOPWATCH
• This stopwatch is water resistant up to five bars (atmospheres), which means you can use it in the rain or in
areas where splashing water is present.
Never, however, operate the buttons of the stopwatch while it is immersed in water.
• You should have the rubber seal that keeps out water and dust replaced every 2 to 3 years.
• Should moisture appear inside the stopwatch, have it checked immediately by your dealer or a CASIO distributor.
DISPLAY
SPECIFICATIONS
NET TIME
CHART
Accuracy at a normal temperature (TIME): 30 seconds per month
(STOPWATCH): 99.9988%
Display capacity:
• Time Display: Hour, minutes, seconds, am/pm, year, month, day and day of the week
Calendar system: Pre-programmed until the year 2099
• Stopwatch Display:
Measuring capacity: (Total elapsed time display) 9 hours 59 minutes 59.999 seconds
(Lap time display) 59 minutes 59.999 seconds
(Split time display) 9 hours 59 minutes 59.999 seconds
Measuring unit: 1/1000 second
Measuring modes: Net time, lap time, split time, 1st-100th place time, lap counter (up to 99)
Memory capacity: 2 sets of 100 records each
START
0
STOP
(a)
START
(a)
STOP
(a + b)
RESET
a
b
(Stoppage time)
BUTTON
OPERATION
DISPLAY
Battery: One lithium battery (type: CR2032)
Approx. 5 years continuous operation on type CR2032
(includes an average of 30 presses of button per day.)
After stopping a net time operation by pressing C, you can resume it by pressing C again.
Download from Www.Somanuals.com. AOllpMeraatninugaTlesmSpeeraartucrhe:A0°nCdtoD4o0°wCn(3lo2°aFdto. 104°F)
|