Casablanca Fan Company Outdoor Ceiling Fan 46UXXD M User Manual

CONTENTS  
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
MOUNTING RECOMMENDATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
PREPARATION INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
FAN INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
CONTROL FEATURES:  
3-SPEED OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10  
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12  
VERSATOUCH 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13  
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15  
READ AND SAVE THESE INSTRUCTIONS  
SAFETY FIRST  
Safety and the proper operation of your Casablanca fan both require a thorough knowledge of the  
product and proper installation; therefore, before attempting to install and operate your Casablanca  
fan, read this owners manual completely and carefully. Retain this manual for future reference.  
CAUTION: To avoid possible electrical shock, make certain that electricity is turned off  
at the circuit breaker or fuse box before attempting any installation procedure.  
BEFORE YOU START  
CAUTION: RISK OF ELECTRICAL SHOCK! All wiring must be performed in accordance with national and local electrical  
codes. If you are unfamiliar with the wiring codes, you should use a qualified electrician. To avoid overheating and  
possible damage to other equipment, do not install control to a receptacle, fluorescent light fixture, motor operated  
appliance, or transformer-supplied appliance.  
This fan is designed to be installed on an existing electrical outlet box. The outlet box must be UL Listed for ceiling fan  
installations, if it is not, a new box must be installed. Casablanca extension poles are available for sloped or high ceiling  
installations.  
This ceiling fan requires a grounded electrical supply of 120 VAC, 60 Hz and a minimum 15 amp circuit. The maximum  
current requirement for the fan with light fixture is 3.8 amps. The fan uses about 1 amp or 100 watts. Maximum light  
current is 2.8 amps or 340 watts of lighting.  
Where wire nuts are employed, be sure all bare wires are within the connectors. When installing the canopy hatch, make  
sure all wires are within the canopy and that no wires are being pinched.  
For best performance and for your warranty to be valid,  
use only genuine Casablanca blades, light fixtures, and accessories.  
SAFE USE  
The blades in each pack are matched for equal  
weight to assure smooth fan operation. If  
more than one fan is being installed, be  
careful not to mix blades from different  
cartons.  
FUSE BOX  
(REMOVE FUSE FOR THE  
CIRCUIT YOU WILL BE  
WORKING ON)  
Inspect the contents of your carton for  
possible shipping or handling damage and  
report any such damage directly to your  
authorized Casablanca dealer.  
18″  
It is always a good idea to have an assistant  
to help with the installation.  
70″  
When cleaning, painting, or working near  
your fan, be very careful of the fan and blades.  
Always turn the power OFF to the ceiling fan  
before servicing it, working on it, or replacing  
light bulbs.  
CIRCUIT BREAKER  
(TRIP BREAKER FOR THE  
CIRCUIT YOU WILL BE  
WORKING ON)  
84″  
Never insert anything into the path of the  
fan blades while the fan is in operation.  
Never install a fan over a pool or spa.  
Never operate a fan that has been damaged  
in any way. Contact Casablanca Fan Company  
by calling toll free 1-888-227-2178, or  
contact your local authorized Casablanca  
dealer for assistance in obtaining service.  
PN 46U43001 AT1108  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAPISTRANO  
Casablanca  
PREPARATION INSTRUCTIONS  
Unpacking: Before assembling and installing your ceiling fan, remove all parts from the shipping cartons and check them  
against the parts listed here. Before discarding packaging material, be certain that all parts have been removed.  
PERMA LOCK™ HARDWARE  
ALLEN SET SCREW  
DOWNROD & BALL  
ASSEMBLY  
1
4-20 x 14  
"
3mm  
ALLEN WRENCH  
(PRE-INSTALLED)  
FAN PREPARATION  
IMPORTANT SAFETY INFORMATION!  
BEFORE STARTING THE INSTALLATION OF YOUR CEILING FAN, INSTALL THE  
THREADED DOWNROD INTO THE MOTOR COUPLING AND LOCK THE ASSEMBLY  
MOTOR  
WIRES  
GROUND  
WIRE  
Prepare for fan installation as follows:  
Step A. Route the wires from the motor through the  
Perma Lock™ downrod and ball assembly.  
DOWNROD  
& BALL  
ASSEMBLY  
Tip: The downrod has a tapered thread  
that is designed to lock completely when  
correctly installed.  
TAPERED  
THREAD  
Step B. Using the provided allen wrench, loosen the set screw  
several turns to allow installation of the downrod. Thread  
the downrod into the motor coupling until it stops turning,  
this will take at least four and a half full turns.  
ALLEN  
SET SCREW  
Step C. Securely tighten the set screw with the provided allen  
wrench to ensure safe operation of your fan.  
MOTOR  
COUPLING  
CAUTION: Failure to fully lock in the down-  
rod before securely tightening the allen set  
screw may cause the fan to separate from  
the downrod during normal operation!  
CEILING HARDWARE  
ADDITIONAL HARDWARE  
21/ 4x 8-32 ROUNDED  
HEAD SCREW (2)  
1x 8-32 ROUNDED  
HEAD SCREW (2)  
CROSSBAR  
MOUNTING  
BRACKET  
WIRE NUT (4)  
FLAT WASHER (2)  
GETTING STARTED  
Installing a New Ceiling Fixture Outlet Box  
Using Existing Ceiling Fixture Outlet Box  
If you do not have an existing fixture located where you wish After turning the power OFF at its source (either circuit breaker  
to place your Casablanca fan, an approved ceiling fixture or fuse box), lower the old fixture and disconnect the wiring.  
outlet box must be installed and wired.  
Check the ceiling fixture outlet box to be sure that it is  
marked Approved for ceiling fan mounting. If it is not, a new  
box must be installed.  
Warning: To reduce the risk of fire, electrical shock,  
or personal injury, mount to outlet box marked  
acceptable for ceiling fan support using the mount-  
ing hardware provided with the outlet box.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAPISTRANO  
Casablanca  
CROSSBAR MOUNTING BRACKET INSTALLATION  
CEILING FAN  
APPROVED  
OUTLET BOX  
Proceed with installation as follows:  
Step 1. Route the wires from the ceiling outlet box through  
the crossbar mounting bracket center hole. Attach the bracket,  
with ground wire and ridges down, to the ceiling fixture out-  
let box with the mounting hardware included with the outlet  
box.  
RIDGE  
SIDE  
DOWN  
Tighten the screws firmly by hand only, being careful not to  
bend the bracket by over tightening.  
CEILING  
WIRING  
CAUTION: To reduce the risk of  
personal injury, use only the  
mounting hardware provided with  
the approved outlet box to install  
the crossbar mounting bracket.  
CROSSBAR  
MOUNTING  
BRACKET  
FLAT  
WASHER  
GREEN  
GROUND  
WIRE  
OUTLET BOX  
MOUNTING  
HARDWARE  
CANOPY HARDWARE  
CANOPY SCREW (4)  
CANOPY LOCK WASHER (4)  
CANOPY  
HATCH  
CANOPY  
CANOPY INSTALLATION  
Step 2. Attach the canopy to the crossbar mount-  
ing bracket with three of the 8-32 x 21/ 4long  
canopy screws and canopy lock washers.  
CROSSBAR MOUNTING  
BRACKET INSTALLED  
Tighten the screw firmly by hand only.  
Note: On sloped ceilings, align the  
canopy opening towards the top or  
room peak.  
CANOPY  
CANOPY LOCK  
WASHERS  
CANOPY  
SCREWS  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAPISTRANO  
Casablanca  
HANGING THE FAN  
Step 3. To hang the fan body in the  
canopy, hold the fan body firmly and in-  
sert the ball into the canopy opening.  
Check that no wires were pinched. Ro-  
tate the fan body until the slot in the  
ball fits into the pin opposite the canopy  
opening.  
BALL  
Fan Hanging Weight  
CAPPED  
BLUE  
is 21 lbs  
D1-OPTION  
WIRE ON  
SLOT  
3-SPEED ONLY  
FOR INDEPENDENT  
W-80 LIGHT  
CONTROL  
PIN  
Note: Independent control of the  
light fixture using a W-80 requires  
an additional independent power wire  
run from the wall switch to the fan.  
See Page 10 for wiring.  
CANOPY ELECTRICAL CONNECTIONS  
Step 4a. Attach the fan wires to the ceiling fixture outlet  
box wiring by placing the bare ends of the wires side by side  
and then securing with a wire nut. Test that the connection  
is secure by pulling on the wire nut. Connect in this order:  
WIRE NUT  
Step 4b.  
GREEN leads from mounting plate and fan to GROUND con-  
ductor of power source. Secure with wire nut.  
WHITE wire from fan to white NEUTRAL wire in ceiling  
fixture outlet box. Secure with wire nut.  
BLUE wire and BLACK power wire from fan to BLACK power  
wire in ceiling outlet box. Secure with wire nut.  
2 BLACK WIRES  
2 WHITE WIRES  
3 GREEN WIRES  
CANOPY HATCH INSTALLATION  
Step 5. Tuck the wires into the canopy  
with the wire nuts pointed upwards, so  
that the WHITE and BLACK wires are on  
opposite sides of the canopy and all wires  
are clear of the canopy opening.  
CANOPY  
HATCH  
Step 6. Install canopy hatch with the last  
canopy screw and lock washer. To do this,  
tilt the fan body away from the hatch  
opening.  
Using the screwdriver, tighten the screws  
firmly by hand only.  
LOCK  
WASHER  
CANOPY  
SCREW  
TILT THE  
FAN TO  
INSTALL  
LAST  
CANOPY  
SCREW  
Step 7. Straighten the fan, then check  
to ensure that there is no movement be-  
tween the canopy and ceiling or Hang-Tru  
ball and top support shaft.  
Note: Write down the  
Serial Number and the  
model number for future  
reference.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAPISTRANO  
Casablanca  
INSTALLING THE BLADE/ BLADE HOLDER TO FAN MOTOR  
PREPARATION  
Step 8. To reach the blade holder mounting  
holes in the fan motor the dummy switch  
housing must be removed.  
Take out the two 5-32 X 9/32” screws secur-  
ing the dummy switch housing and remove.  
Put the two (2) screws aside for the mo-  
ment, they will be used in Step 15 to install  
the switch housing after the blades are in-  
stalled.  
The dummy switch housing is used only when  
shipping the fan.  
Note: Save these two screws–they  
will be used in Step 15!  
DUMMY  
SWITCH HOUSING  
MOUNT SCREW  
5-32 X 9/ 32”  
(2)  
DUMMY  
SWITCH  
HOUSING  
BLADE & BLADE HOLDER HARDWARE  
BLADE SCREW  
(4 PER BLADE)  
BLADE HOLDER  
SCREW  
(2 PER BLADE)  
RUBBER GROMMET  
(4 PER BLADE)  
BLADE  
HOLDER  
RUBBER GROMMET INSTALLATION  
Step 9. Insert a rubber grommet through  
each blade hole of every blade. Inspect  
both sides of the blade to assure that  
the lips of the grommet are fully engaged.  
CORRECT INSTALLATION  
INCORRECT INSTALLATION  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAPISTRANO  
Casablanca  
BLADE INSTALLATION  
Step 10. Attach each blade to a blade  
holder securing it with the four blade  
screws provided.  
Using the screwdriver, tighten securely  
by hand only.  
BLADE SCREW  
(4 PER BLADE)  
BLADE  
BLADE  
HOLDER  
REMOVE SHIPPING BLOCKS  
Step 11. On the flywheel remove the five  
shipping blocks by unscrewing the screws.  
Set these screws aside for installing the  
blades in Step 12.  
SHIPPING  
BLOCKS  
Discard the five shipping blocks.  
Note: Save these five screws, they  
will be used in Step 12!  
BLADE/ BLADE HOLDER INSTALLATION  
Step 12. Using the five screws removed in  
Step 11, and the five additional screws from  
the pack, attach each blade/ blade holder as-  
sembly to the motor.  
Using the screwdriver, tighten securely by  
hand only.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAPISTRANO  
Casablanca  
COMPLETING INSTALLATION  
SWITCH HOUSING  
MOUNT SCREW  
(REMOVED IN STEP 8)  
5-32 X 9/ 32″  
VERSATOUCH 2  
SWITCH HOUSING  
AND CAP ASSEMBLY  
3-SPEED  
SWITCH HOUSING  
AND CAP ASSEMBLY  
(2)  
PREPARATION  
VERSATOUCH 2  
3-SPEED  
SWITCH HOUSING  
Step 13. Locate the switch housing/ cap  
assembly and remove the two 8-32 X 3/ 8″  
screws holding the cap onto the switch  
housing.  
CONNECTOR  
(3-SPEED ONLY)  
SWITCH  
HOUSING  
Note: Save these two screws–they  
will be used in Step 19!  
CAP  
CAP SCREW  
8-32 X 3/ 8″  
(2)  
CAP SCREW  
8-32 X 3/ 8″  
(2)  
(3-SPEED ONLY) CONNECTING THE SWITCH HOUSING ASSEMBLY  
Step 14. If your fan is a VersaTouch 2  
model, please skip to Step 15.  
For 3-Speed models, hold the switch hous-  
ing up to the fan and connect the motor  
plug to the switch housing socket. The  
connector is keyed to ensure correct in-  
stallation.  
SWITCH  
HOUSING  
CONNECTOR  
(SOCKET)  
Note: Do not force the connectors–  
check that they are orientated so  
the keying will match!  
MOTOR  
CONNECTOR  
(PLUG)  
INSTALL SWITCH HOUSING MOUNTING SCREWS  
VERSATOUCH 2  
Step 15. Install the two (2) 5-32 X 932″  
3-SPEED  
screws removed in Step 8, leaving ap-  
1
proximately ⁄8“ of the threads exposed  
for installation of the switch housing.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAPISTRANO  
Casablanca  
INSTALLING THE SWITCH HOUSING ASSEMBLY  
VERSATOUCH 2  
3-SPEED  
Step 16. Line up the two inner clear-  
ance holes in the cap with the two  
threaded holes in the switch mounting  
plate standoffs.  
CAUTION! Before continuing to the  
next step check that a wire or com-  
ponent inside the switch housing  
will not be pinched as it is installed.  
Step 17. Use the two (2) 5-32 X 9/ 32″  
screws removed in Step 8 to install the  
switch housing assembly.  
SWITCH HOUSING  
MOUNT SCREW  
5-32 X 9/ 32″  
(2)  
Tighten securely by hand only.  
INSTALLING THE SWITCH HOUSING CAP  
VERSATOUCH 2  
3-SPEED  
Step 18. Line up the two clearance holes  
in the cap with the two threaded holes  
on the raised rim of the switch housing.  
Press the cap onto the switch housing to  
seat the guide pins into the alignment  
holes of the switch housing.  
Step 19. Using the two (2) 8-32 X 3/ 8″  
screws removed in Step 13, install the  
cap onto the switch housing.  
Tighten securely by hand only.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-SPEED OPERATION  
Pull-chain switches on the fan control the fan and lights.  
Using the fan control pull-chain switch: Fan off at start.  
First pull: fan ON, low speed  
OPTIONAL LIGHT  
PULL CHAIN  
SWITCH  
FAN & SPEED  
CONTROL  
PULL CHAIN SWITCH  
Second pull: medium speed  
Third pull: high speed  
Fourth pull: fan OFF  
Using the optional light pull-chain switch: Light off at start.  
First pull: light ON  
Second pull: light OFF  
Direction of blade rotation is controlled by the reverse slide  
switch on the side of the switch housing.  
No changes in household wiring are required.  
REVERSE  
SWITCH  
3-SPEED OPTIONAL LIGHT FIXTURE INSTALLATION  
NOTE: If a separate circuit is used to control the lights from a wall  
control, the BLUE D1-Option wire in the canopy should be connected  
to that switch leg with the BLACK fan power wire.  
SWITCH  
HOUSING  
1. Refer to light kit instructions to assemble and attach your light  
kit correctly.  
COLLAR  
2. Remove the two 8-32 screws from the switch housing cap.  
3. Remove the plug from switch housing.  
4. Install pull-chain switch and finger tighten collar on switch.  
5. Connect one wire from pull-chain switch to the BLUE D1-Option  
wire. Secure splice with a wire nut.  
6. Connect other wire from pull-chain switch to BLACK wire from  
light kit. Secure splice with a wire nut.  
7. Connect WHITE wire from switch housing to WHITE wire from light  
kit. Secure splice with a wire nut.  
8. At the canopy, connect the BLACK and BLUE wires.  
3-SPEED OPTIONAL WALL CONTROL W-40  
The W-40 wall control provides four-speed control of fan from a convenient wall location.  
The W-40 is designed to replace a standard wall switch and will fit wall boxes with a depth  
of 2" or greater. Not for use with single pull-chain fan/ light option wiring.  
To install a W-40 wall control in place of an existing wall switch, follow the instructions on  
the W-40 package.  
Note: No rewiring is required if the fan is replacing an existing light fixture.  
Operation of the fan from the wall switch is simple:  
1. Turn knob to obtain desired speed setting.  
CAUTION! Failure to set the pull-chain speed to HIGH can result in faulty operation of  
the fan and damage to the W-40 wall control. To confirm fan is set to HIGH: Turn W-40  
fan speed switch to 'HI' - set fastest fan speed with pull chain.  
3-SPEED OPTIONAL WALL CONTROL W-80  
The W-80 wall control provides separate control of fan and light with two separate knobs  
from a convenient wall location. The W-80 is designed to replace a standard wall switch and  
wall boxes with a depth of 2" or greater. Requires two hot leads from wall box to ceiling  
wiring box.  
LO  
To install a W-80 wall control in place of an existing wall switch, follow the instructions on  
the W-80 package.  
Operation of the fan from the wall switch is simple:  
1. Turn the upper knob to the desired fan speed.  
2. Turn the lower knob to the desired light setting.  
CAUTION! Failure to set the pull-chain speed to HIGH can result in faulty operation of  
the fan and damage to the W-80 wall control. To confirm fan is set to HIGH: Turn W-80  
fan speed switch to 'HI' - set fastest fan speed with pull chain.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-SPEED W-40 WALL CONTROL OF THE FAN  
The W-40 allows the choice of four  
(4) different speed settings.  
No light fixture is used.  
Set the FAN pull chain switch to the  
HIGH speed setting.  
No changes in household or fan wiring  
are required.  
The fan may be turned ON and OFF by  
the W-40 wall control.  
CAUTION! Failure to set the pull-chain  
speed to HIGH can result in faulty  
operation of the fan and damage to  
the W-40 wall control. To confirm fan  
is set to HIGH: Turn W-40 fan speed  
switch to 'HI' - set fastest fan speed  
with pull chain.  
R
3-SPEED W-80 WALL CONTROL OF THE FAN & LIGHT(S)  
The fan may be turned ON and OFF  
by the W-80 wall control.  
The lights may be turned ON and  
OFF by the W-80 and the inten-  
sity adjusted from low to high.  
The fan must be supplied with two  
independent 120V AC supply  
wires.  
Set the FAN pull chain switch to  
the HIGH speed setting.  
Turn the lights ON at the fan.  
The W-80 allows the choice of four  
(4) different speed settings.  
CAUTION! Failure to set the pull-  
chain speed to HIGH can result in  
faulty operation of the fan and  
damage to the W-80 wall control.  
To confirm fan is set to HIGH: Turn  
W-80 fan speed switch to 'HI' -  
set fastest fan speed with pull  
chain.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
Before Requesting Service: Please follow this troubleshooting guide before contacting your dealer for assistance.  
Caring for Finishes: For cleaning, a soft brush or lint-free cloth Never Lubricate this Fan!  
should be used to prevent scratching the finish. A vacuum cleaner The precision motor at the heart of your Casablanca fan features  
brush nozzle can remove heavier dust. Surface smudges or an accu- sealed bearings that are lubricated for life. Do not attempt to oil  
mulation of dirt and dust can easily be removed by using a mild the motor.  
detergent and slightly dampened soft cloth. An antistatic agent Changing Light Bulbs  
may be used, but never use abrasive cleaning agents. These will Be sure to turn power to the fan OFF at the wall switch or circuit  
damage the finish. Painted and high-gloss blades may be cleaned breaker before changing light bulbs. Replace bulbs with same type  
in the same manner.  
as removed from the fixture. Each fan is rated for a maximum TOTAL  
Blades: Wood finish blades should be cleaned with a furniture pol- wattage of lighting.  
ishing cloth. Occasionally, a light coat of furniture polish may be Exceeding the rated maximum allowable wattage for the fan will  
applied for added protection and beauty.  
burn out the fan electronics module and void the warranty.  
PROBLEM  
FAN WILL NOT START  
3-SPEED  
POSSIBLE REMEDIES..  
Check main circuit fuses, circuit breakers, or wall switch position.  
Check all wire connections, making sure the power is turned off during this inspection.  
Check that reverse switch is not set in center of throw.  
FAN WOBBLES OR SHAKES Be sure canopy pin is properly set into the slot on the ball.  
EXCESSIVELY  
Check the screws holding the blade holders to the flywheel (or direct drive motor). Tighten as necessary.  
Check that bladeholders have not been bent during installation.  
FAN NOISY DURING  
OPERATION  
Check and tighten light fixture retaining screws, glass shade screws and/ or the light bulb(s) as neccessary.  
Tighten the blade to bladeholder screws.  
Tighten canopy screws and mounting plate assembly.  
Check and tighten blade holders to flywheel (or direct drive motor).  
Make sure all screws in the motor housing are snug, but not overly tight.  
Check that the wire nuts inside the canopy and switch housing are not touching the metal parts or have  
fallen off the wire splices. Tighten or adjust as necessary.  
BREAK-IN PERIOD  
Let fan run at high speed for two (2) hours  
DOES NOT RUN ON  
LOW SPEED  
If new, break-in” may be required - run at higher speed for several days  
FAN RUNS SLOWLY IN EITHER DIRECTION IF ROTATION IS STARTED BY HAND; WILL NOT REVERSE: Defective reverse switch; defective  
capacitor; or open motor winding: Replace reverse switch assembly; replace PCB assembly; or replace motor unit.  
FAN WILL NOT OPERATE AT PROPER SPEEDS OR WILL NOT OPERATE AT ANY SPEED: Defective three-speed pull-chain switch assembly; or  
defective capacitor: Replace three-speed pull-chain switch assembly; or replace PCB assembly.  
PERFORMANCE AND ENERGY INFORMATION  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2
VERSATOUCH 2 INSTALLATION  
W-72  
CONTROL  
HOLDER  
DRYWALL  
ANCHOR  
6-32 (2)  
WOOD  
SCREW  
1” (2)  
SCREW  
6-32 X 3/ 8”  
(2)  
SCREW  
6-32 X 1”  
(2)  
W-72  
CONTROL  
12V BATTERY  
VERSATOUCH 2 CONTROL BRACKET INSTALLATION  
CAUTION! Do not use with wall dimmer.  
STANDARD  
TOGGLE  
SWITCH  
ROCKER  
TYPE  
LIGHT  
SWITCH  
INNER  
MOUNTING  
HOLES  
OUTER  
MOUNTING  
HOLES  
SWITCH  
COVER  
PLATE  
SWITCH  
COVER  
PLATE  
CONTROL  
CONTROL  
BRACKET  
BRACKET  
Standard Light Switch  
Step A. Remove the two screws holding the switch cover  
plate. Do not remove the cover plate.  
Step B. Orient the control bracket as shown and line up the  
two inner mounting holes with those on the switch.  
Step C. Install and tighten screws by hand only.  
Rocker Light Switch  
Step A. Break off the two tabs by pushing outward.  
Step B. Remove the two screws holding the switch cover  
plate. Do not remove the cover plate.  
Step C. Orient the control bracket as shown and line up the  
two inner mounting holes with those on the switch.  
Step D. Install and tighten screws by hand only.  
Wall Installation  
Note: The wall anchors and 6-32 x 1” screws may be  
used in situations where mounting to a stud is not pos-  
sible. Use the inner mounting holes. After securing the  
anchor, discard the anchors pointed screws and use the  
6-32 decor ovalhead screws supplied.  
Step A. Locate a 2x4 wall  
stud in a convenient  
location.  
Step B. Orient the control  
bracket as shown over the  
2x4 stud.  
Step C. Use the 1” wood  
screws in either the inner  
or outer mounting holes.  
Install and tighten screws  
by hand only.  
ANCHOR  
PANHEAD  
SCREW  
DRYWALL ANCHOR  
WOOD  
SCREW 1”  
DECOR OVALHEAD SCREW  
6-32 X 1”  
Changes or modifications not expressly ap-  
proved in writing by Casablanca Fan Co. may  
void the users authority to operate this  
equipment.  
This device complies with RSS-210 of Industry Canada. Operation is subject to  
the following two conditions: (1) this device may not cause interference, and  
(2) this device must accept any interference, including interference that may  
cause undesired operation of the device.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2
VERSATOUCH 2 OPERATION  
SEND SIGNAL  
LED  
Fan Control  
LIGHT  
To start the fan. Press the selected speed button to run the fan at the desired speed.  
LO=Low speed MED=Medium speed HI=High speed  
To turn off the fan. Press the FAN OFF button.  
MED  
LO  
Airflow Direction  
To reverse the airflow press the REVERSE button. Reverse operates at any speed whether fan  
is on or off. The fan returns to its set speed after reversing.  
Light Control  
HI  
Turn the light on or off independently from the fan by pressing the LIGHT button. Keep  
pressing the button in excess of 0.7 seconds, it becomes a dimmer. The light varies from  
bright’ to dim’ over approximately 8 seconds. This sequence will reverse the light when it  
reaches the brightest or dimmest level if you continue to hold the LIGHT button. Release the  
button when the desired level is reached.  
FAN  
STOP  
Auto Resume  
REVERSE  
Quick (pressing less than 0.7 seconds) on/ off operation of the LIGHT button maintains the  
desired brightness level set previously.  
VERSATOUCH 2 CHANGING FREQUENCY SETTING  
Note: All fans leave the factory set to 00000.  
You will only have to change the dip switch settings in the remote if  
you are using more than one fan in the same area and want to control  
them separately.  
VERSATOUCH 2  
CONTROL  
Step 1. At the circuit breaker or fuse box, turn the power off for the fan  
you want to change.  
(BACK)  
Step 2. Open the battery door of the VersaTouch control and remove  
the batteries.  
Step 3. Change the dip switch settings, assuring that they are different  
from the previously installed VersaTouch fan.  
Step 4. Re-install the batteries and the battery door on the control.  
DIP SWITCH  
SET TO ‘10000’  
DIP SWITCH  
SET TO ‘01001’  
Step 5. At the circuit breaker or fuse box, turn the power back on for  
the fan whose frequency you are changing.  
Step 6. Within 20 seconds of restoring power, push the Hi, Med, and Lo  
buttons (in that order).  
WITHIN 20 SECONDS OF  
2
TURNING THE FAN ON,  
PRESS IN THIS ORDER TO  
SET NEW FREQUENCY:  
1. HI  
Note: You may want to label your controls to  
assure you do not mix them up.  
2. MED  
3. LO  
WARNING: Do not turn the power off at the circuit breaker,  
then back on, for the previously installed Versa• Touch 2  
fan(s), as you may inadvertantly change the frequency set-  
tings for it as well.  
3
1
VERSATOUCH 2 IF FAN DOES NOT WORK  
If the fan is not functioning after installation:  
2
Step 1. Check to make sure that batteries are installed correctly  
in the control.  
Step 2. Turn the power off to the fan (from the circuit breaker)  
for at least 5 seconds.  
3
1
Step 3. Turn the power back on (at the circuit breaker) and push  
the Hi, Med, and Low buttons–in that order–within 20 seconds.  
Step 4. The fan should now function properly.  
PRESS IN THIS ORDER TO SET NEW  
FREQUENCY:  
CIRCUIT BREAKER  
OR FUSE BOX  
1. HI  
2. MED  
3. LO  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2
TROUBLESHOOTING  
VERSATOUCH 2  
PROBLEM  
PROBLEM  
POSSIBLE REMEDIES  
POSSIBLE REMEDIES..  
Before Requesting Service: Please follow this troubleshooting guide before contacting your dealer for assistance.  
FAN WILL NOT START  
Check main circuit fuses, circuit breakers, or wall switch position. Check all wire connections, making  
sure the power is turned off during this inspection.  
Pin connectors are not making good contact. Check the connections in the switch housing and under the  
top cover.  
Battery weak - install fresh battery.  
Fan receiver defective - replace.  
Check the frequency setting: Turn power off, at the circuit breaker, only for the fan not functioning for  
at least 5 seconds; turn the power back on; within 20 seconds press the Hi, Med, and Lo buttons (in that  
order) to set the frequency of the fan to the control.  
FAN WOBBLES OR SHAKES Be sure canopy pin is properly set into the slot on the ball.  
EXCESSIVELY  
Check that bladeholders have not been bent during installation and blades are balanced.  
Hanger bracket and/ or ceiling outlet are loosely attached: Make sure that the hanger bracket is tightly.  
attached to the ceiling outlet box. Make sure that the downrod assembly is secured firmly.  
Downrod is loosely attached to downrod base: Make sure that all screws are securely tightened .  
FAN NOISY DURING  
OPERATION  
Check and tighten light fixture retaining screws, glass shade screws and/ or the light bulb(s).  
Tighten canopy screws and mounting plate assembly. Check that the wire nuts inside the canopy and  
switch housing are not touching the metal parts or have fallen off the wire splices. Tighten as necessary.  
Tighten blade holders to flywheel (or direct drive motor)/ and blade to bladeholder screws.  
Make sure all screws in the motor housing are snug, but not overly tight. Defective bulb: Replace bulb.  
DOES NOT RUN ON  
LOW SPEED  
If new, break-in” may be required - run at higher speed for several days.  
Not using Alkaline batteries: Replace with Alkaline batteries.  
BATTERY LIFE  
SEEMS SHORT  
LIGHT O.K., NO FAN: Pin connectors are not making good contact, check 9 pin connector under top cover.  
FAN O.K., NO LIGHT; Defective receiver; Replace receiver. Defective motor; Replace motor. Broken socket; Replace socket. Defective receiver;  
Replace Receiver.  
FAN AND LIGHT ON FULL, NO CONTROL; Defective receiver; Replace Receiver.  
MISSING ONE SPEED: Defective receiver; Replace Receiver.  
FAN DOESN’T CHANGE SPEED, LIGHT O.K.: Replace receiver.  
FAN O.K., LIGHT NOT DIM: Defective receiver; Replace Receiver.  
NO REVERSE: Defective receiver; Replace Receiver.  
FAN OPERATES ONLY WHEN TRANSMITTER IS CLOSED: Check antenna wire is not touching metal plate.  
FAN STARTS WORKING BY ITSELF: Frequency interference; Change frequency as described on Page 2.  
For questions or to locate the nearest  
Casablanca Authorized Service Center  
call toll free:  
1-888-227-2178  
or visit us on the web at:  
www.CasablancaFanCo.com  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRODUCT SPECIFICATIONS  
188mm x 20mm Direct Drive™  
45" or 53"  
16°  
5
®
Model Name:  
Capistrano  
Motor:  
Model Number: 46XXD/M and 46UXXD/M  
Blade Span With:  
Blade Pitch:  
Dimensions:  
A =  
B = 12.75"  
C = 3"  
11.1"  
No. of Blades:  
Technology:  
3-Speed  
NOTE: Dimension B  
includes light fixture  
and glass.  
®
Versa•Touch2 W-72  
D = 12.6"  
E =  
5.6"  
Airflow:  
6,691 cfm  
89 watts  
Electricity Use*:  
Weight:  
21 lbs.  
Airflow Efficiency*: 75 cfm/watt  
* Performance data is for fan only. No lighting wattage is included.  
Measurements taken with 21" blades.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Black Decker Toaster TRO18 User Manual
Bolens Yard Vacuum 769 00407 User Manual
Bosch Power Tools Saw CCS180 User Manual
Brocade Communications Systems Network Router 53 1002373 02 User Manual
Cabletron Systems Switch TSX 1620 User Manual
Cadet Electric Heater EBHN1000 User Manual
Carrier Home Security System 33CNOAANT1 User Manual
Casio Watch 2235 1 User Manual
Chief Manufacturing Indoor Furnishings FSA 1001 User Manual
Cisco Systems Network Card WS C2950 12 User Manual