Casablanca Fan Company Outdoor Ceiling Fan 46UXXD M User Manual |
CONTENTS
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
MOUNTING RECOMMENDATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
PREPARATION INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
FAN INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
CONTROL FEATURES:
3-SPEED OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
VERSA•TOUCH 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
READ AND SAVE THESE INSTRUCTIONS
SAFETY FIRST
Safety and the proper operation of your Casablanca fan both require a thorough knowledge of the
product and proper installation; therefore, before attempting to install and operate your Casablanca
fan, read this owner’s manual completely and carefully. Retain this manual for future reference.
CAUTION: To avoid possible electrical shock, make certain that electricity is turned off
at the circuit breaker or fuse box before attempting any installation procedure.
BEFORE YOU START
• CAUTION: RISK OF ELECTRICAL SHOCK! All wiring must be performed in accordance with national and local electrical
codes. If you are unfamiliar with the wiring codes, you should use a qualified electrician. To avoid overheating and
possible damage to other equipment, do not install control to a receptacle, fluorescent light fixture, motor operated
appliance, or transformer-supplied appliance.
• This fan is designed to be installed on an existing electrical outlet box. The outlet box must be UL Listed for ceiling fan
installations, if it is not, a new box must be installed. Casablanca extension poles are available for sloped or high ceiling
installations.
• This ceiling fan requires a grounded electrical supply of 120 VAC, 60 Hz and a minimum 15 amp circuit. The maximum
current requirement for the fan with light fixture is 3.8 amps. The fan uses about 1 amp or 100 watts. Maximum light
current is 2.8 amps or 340 watts of lighting.
• Where wire nuts are employed, be sure all bare wires are within the connectors. When installing the canopy hatch, make
sure all wires are within the canopy and that no wires are being pinched.
For best performance and for your warranty to be valid,
use only genuine Casablanca blades, light fixtures, and accessories.
SAFE USE
• The blades in each pack are matched for equal
weight to assure smooth fan operation. If
more than one fan is being installed, be
careful not to mix blades from different
cartons.
FUSE BOX
(REMOVE FUSE FOR THE
CIRCUIT YOU WILL BE
WORKING ON)
• Inspect the contents of your carton for
possible shipping or handling damage and
report any such damage directly to your
authorized Casablanca dealer.
18″
• It is always a good idea to have an assistant
to help with the installation.
70″
• When cleaning, painting, or working near
your fan, be very careful of the fan and blades.
Always turn the power OFF to the ceiling fan
before servicing it, working on it, or replacing
light bulbs.
CIRCUIT BREAKER
(TRIP BREAKER FOR THE
CIRCUIT YOU WILL BE
WORKING ON)
84″
• Never insert anything into the path of the
fan blades while the fan is in operation.
• Never install a fan over a pool or spa.
• Never operate a fan that has been damaged
in any way. Contact Casablanca Fan Company
by calling toll free 1-888-227-2178, or
contact your local authorized Casablanca
dealer for assistance in obtaining service.
PN 46U43001 AT1108
1
Download from Www.Somanuals.com. All Manuals Search And Download.
™
CAPISTRANO
Casablanca
PREPARATION INSTRUCTIONS
Unpacking: Before assembling and installing your ceiling fan, remove all parts from the shipping cartons and check them
against the parts listed here. Before discarding packaging material, be certain that all parts have been removed.
PERMA LOCK™ HARDWARE
•
ALLEN SET SCREW
DOWNROD & BALL
ASSEMBLY
1
⁄
4-20 x 1⁄4
"
3mm
ALLEN WRENCH
(PRE-INSTALLED)
FAN PREPARATION
IMPORTANT SAFETY INFORMATION!
BEFORE STARTING THE INSTALLATION OF YOUR CEILING FAN, INSTALL THE
THREADED DOWNROD INTO THE MOTOR COUPLING AND LOCK THE ASSEMBLY
MOTOR
WIRES
GROUND
WIRE
Prepare for fan installation as follows:
Step A. Route the wires from the motor through the
Perma Lock™ downrod and ball assembly.
•
DOWNROD
& BALL
ASSEMBLY
Tip: The downrod has a tapered thread
that is designed to lock completely when
correctly installed.
TAPERED
THREAD
Step B. Using the provided allen wrench, loosen the set screw
several turns to allow installation of the downrod. Thread
the downrod into the motor coupling until it stops turning,
this will take at least four and a half full turns.
ALLEN
SET SCREW
Step C. Securely tighten the set screw with the provided allen
wrench to ensure safe operation of your fan.
MOTOR
COUPLING
CAUTION: Failure to fully lock in the down-
rod before securely tightening the allen set
screw may cause the fan to separate from
the downrod during normal operation!
CEILING HARDWARE
ADDITIONAL HARDWARE
21/ 4″ x 8-32 ROUNDED
HEAD SCREW (2)
1″ x 8-32 ROUNDED
HEAD SCREW (2)
CROSSBAR
MOUNTING
BRACKET
WIRE NUT (4)
FLAT WASHER (2)
GETTING STARTED
Installing a New Ceiling Fixture Outlet Box
Using Existing Ceiling Fixture Outlet Box
If you do not have an existing fixture located where you wish After turning the power OFF at its source (either circuit breaker
to place your Casablanca fan, an approved ceiling fixture or fuse box), lower the old fixture and disconnect the wiring.
outlet box must be installed and wired.
Check the ceiling fixture outlet box to be sure that it is
marked ‘Approved for ceiling fan mounting’. If it is not, a new
box must be installed.
Warning: To reduce the risk of fire, electrical shock,
or personal injury, mount to outlet box marked
acceptable for ceiling fan support using the mount-
ing hardware provided with the outlet box.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
™
CAPISTRANO
Casablanca
CROSSBAR MOUNTING BRACKET INSTALLATION
CEILING FAN
APPROVED
OUTLET BOX
Proceed with installation as follows:
Step 1. Route the wires from the ceiling outlet box through
the crossbar mounting bracket center hole. Attach the bracket,
with ground wire and ridges down, to the ceiling fixture out-
let box with the mounting hardware included with the outlet
box.
RIDGE
SIDE
DOWN
Tighten the screws firmly by hand only, being careful not to
bend the bracket by over tightening.
CEILING
WIRING
CAUTION: To reduce the risk of
personal injury, use only the
mounting hardware provided with
the approved outlet box to install
the crossbar mounting bracket.
CROSSBAR
MOUNTING
BRACKET
FLAT
WASHER
GREEN
GROUND
WIRE
OUTLET BOX
MOUNTING
HARDWARE
CANOPY HARDWARE
CANOPY SCREW (4)
CANOPY LOCK WASHER (4)
CANOPY
HATCH
CANOPY
CANOPY INSTALLATION
Step 2. Attach the canopy to the crossbar mount-
ing bracket with three of the 8-32 x 21/ 4″ long
canopy screws and canopy lock washers.
CROSSBAR MOUNTING
BRACKET INSTALLED
Tighten the screw firmly by hand only.
Note: On sloped ceilings, align the
canopy opening towards the top or
room peak.
CANOPY
CANOPY LOCK
WASHERS
CANOPY
SCREWS
4
Download from Www.Somanuals.com. All Manuals Search And Download.
™
CAPISTRANO
Casablanca
HANGING THE FAN
Step 3. To hang the fan body in the
canopy, hold the fan body firmly and in-
sert the ball into the canopy opening.
Check that no wires were pinched. Ro-
tate the fan body until the slot in the
ball fits into the pin opposite the canopy
opening.
BALL
Fan Hanging Weight
CAPPED
BLUE
is 21 lbs
D1-OPTION
WIRE ON
SLOT
3-SPEED ONLY
FOR INDEPENDENT
W-80 LIGHT
CONTROL
PIN
Note: Independent control of the
light fixture using a W-80 requires
an additional independent power wire
run from the wall switch to the fan.
See Page 10 for wiring.
CANOPY ELECTRICAL CONNECTIONS
Step 4a. Attach the fan wires to the ceiling fixture outlet
box wiring by placing the bare ends of the wires side by side
and then securing with a wire nut. Test that the connection
is secure by pulling on the wire nut. Connect in this order:
WIRE NUT
Step 4b.
• GREEN leads from mounting plate and fan to GROUND con-
ductor of power source. Secure with wire nut.
• WHITE wire from fan to white NEUTRAL wire in ceiling
fixture outlet box. Secure with wire nut.
• BLUE wire and BLACK power wire from fan to BLACK power
wire in ceiling outlet box. Secure with wire nut.
2 BLACK WIRES
2 WHITE WIRES
3 GREEN WIRES
CANOPY HATCH INSTALLATION
Step 5. Tuck the wires into the canopy
with the wire nuts pointed upwards, so
that the WHITE and BLACK wires are on
opposite sides of the canopy and all wires
are clear of the canopy opening.
CANOPY
HATCH
Step 6. Install canopy hatch with the last
canopy screw and lock washer. To do this,
tilt the fan body away from the hatch
opening.
Using the screwdriver, tighten the screws
firmly by hand only.
LOCK
WASHER
CANOPY
SCREW
TILT THE
FAN TO
INSTALL
LAST
CANOPY
SCREW
Step 7. Straighten the fan, then check
to ensure that there is no movement be-
tween the canopy and ceiling or Hang-Tru
ball and top support shaft.
Note: Write down the
Serial Number and the
model number for future
reference.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
™
CAPISTRANO
Casablanca
INSTALLING THE BLADE/ BLADE HOLDER TO FAN MOTOR
PREPARATION
Step 8. To reach the blade holder mounting
holes in the fan motor the dummy switch
housing must be removed.
Take out the two 5-32 X 9/32” screws secur-
ing the dummy switch housing and remove.
Put the two (2) screws aside for the mo-
ment, they will be used in Step 15 to install
the switch housing after the blades are in-
stalled.
The dummy switch housing is used only when
shipping the fan.
Note: Save these two screws–they
will be used in Step 15!
DUMMY
SWITCH HOUSING
MOUNT SCREW
5-32 X 9/ 32”
(2)
DUMMY
SWITCH
HOUSING
BLADE & BLADE HOLDER HARDWARE
BLADE SCREW
(4 PER BLADE)
BLADE HOLDER
SCREW
(2 PER BLADE)
RUBBER GROMMET
(4 PER BLADE)
BLADE
HOLDER
RUBBER GROMMET INSTALLATION
Step 9. Insert a rubber grommet through
each blade hole of every blade. Inspect
both sides of the blade to assure that
the lips of the grommet are fully engaged.
CORRECT INSTALLATION
INCORRECT INSTALLATION
6
Download from Www.Somanuals.com. All Manuals Search And Download.
™
CAPISTRANO
Casablanca
BLADE INSTALLATION
Step 10. Attach each blade to a blade
holder securing it with the four blade
screws provided.
Using the screwdriver, tighten securely
by hand only.
BLADE SCREW
(4 PER BLADE)
BLADE
BLADE
HOLDER
REMOVE SHIPPING BLOCKS
Step 11. On the flywheel remove the five
shipping blocks by unscrewing the screws.
Set these screws aside for installing the
blades in Step 12.
SHIPPING
BLOCKS
Discard the five shipping blocks.
Note: Save these five screws, they
will be used in Step 12!
BLADE/ BLADE HOLDER INSTALLATION
Step 12. Using the five screws removed in
Step 11, and the five additional screws from
the pack, attach each blade/ blade holder as-
sembly to the motor.
Using the screwdriver, tighten securely by
hand only.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
™
CAPISTRANO
Casablanca
COMPLETING INSTALLATION
SWITCH HOUSING
MOUNT SCREW
(REMOVED IN STEP 8)
5-32 X 9/ 32″
VERSA•TOUCH 2
SWITCH HOUSING
AND CAP ASSEMBLY
3-SPEED
SWITCH HOUSING
AND CAP ASSEMBLY
(2)
PREPARATION
VERSA•TOUCH 2
3-SPEED
SWITCH HOUSING
Step 13. Locate the switch housing/ cap
assembly and remove the two 8-32 X 3/ 8″
screws holding the cap onto the switch
housing.
CONNECTOR
(3-SPEED ONLY)
SWITCH
HOUSING
Note: Save these two screws–they
will be used in Step 19!
CAP
CAP SCREW
8-32 X 3/ 8″
(2)
CAP SCREW
8-32 X 3/ 8″
(2)
(3-SPEED ONLY) CONNECTING THE SWITCH HOUSING ASSEMBLY
Step 14. If your fan is a Versa•Touch 2
model, please skip to Step 15.
For 3-Speed models, hold the switch hous-
ing up to the fan and connect the motor
plug to the switch housing socket. The
connector is keyed to ensure correct in-
stallation.
SWITCH
HOUSING
CONNECTOR
(SOCKET)
Note: Do not force the connectors–
check that they are orientated so
the keying will match!
MOTOR
CONNECTOR
(PLUG)
INSTALL SWITCH HOUSING MOUNTING SCREWS
VERSA•TOUCH 2
Step 15. Install the two (2) 5-32 X 9⁄32″
3-SPEED
screws removed in Step 8, leaving ap-
1
proximately ⁄8“ of the threads exposed
for installation of the switch housing.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
™
CAPISTRANO
Casablanca
INSTALLING THE SWITCH HOUSING ASSEMBLY
VERSA•TOUCH 2
3-SPEED
Step 16. Line up the two inner clear-
ance holes in the cap with the two
threaded holes in the switch mounting
plate standoffs.
CAUTION! Before continuing to the
next step check that a wire or com-
ponent inside the switch housing
will not be pinched as it is installed.
Step 17. Use the two (2) 5-32 X 9/ 32″
screws removed in Step 8 to install the
switch housing assembly.
SWITCH HOUSING
MOUNT SCREW
5-32 X 9/ 32″
(2)
Tighten securely by hand only.
INSTALLING THE SWITCH HOUSING CAP
VERSA•TOUCH 2
3-SPEED
Step 18. Line up the two clearance holes
in the cap with the two threaded holes
on the raised rim of the switch housing.
Press the cap onto the switch housing to
seat the guide pins into the alignment
holes of the switch housing.
Step 19. Using the two (2) 8-32 X 3/ 8″
screws removed in Step 13, install the
cap onto the switch housing.
Tighten securely by hand only.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
3-SPEED ♦ OPERATION
Pull-chain switches on the fan control the fan and lights.
Using the fan control pull-chain switch: Fan off at start.
First pull: fan ON, low speed
OPTIONAL LIGHT
PULL CHAIN
SWITCH
FAN & SPEED
CONTROL
PULL CHAIN SWITCH
Second pull: medium speed
Third pull: high speed
Fourth pull: fan OFF
Using the optional light pull-chain switch: Light off at start.
First pull: light ON
Second pull: light OFF
Direction of blade rotation is controlled by the reverse slide
switch on the side of the switch housing.
No changes in household wiring are required.
REVERSE
SWITCH
3-SPEED ♦ OPTIONAL LIGHT FIXTURE INSTALLATION
NOTE: If a separate circuit is used to control the lights from a wall
control, the BLUE D1-Option wire in the canopy should be connected
to that switch leg with the BLACK fan power wire.
SWITCH
HOUSING
1. Refer to light kit instructions to assemble and attach your light
kit correctly.
COLLAR
2. Remove the two 8-32 screws from the switch housing cap.
3. Remove the plug from switch housing.
4. Install pull-chain switch and finger tighten collar on switch.
5. Connect one wire from pull-chain switch to the BLUE D1-Option
wire. Secure splice with a wire nut.
6. Connect other wire from pull-chain switch to BLACK wire from
light kit. Secure splice with a wire nut.
7. Connect WHITE wire from switch housing to WHITE wire from light
kit. Secure splice with a wire nut.
8. At the canopy, connect the BLACK and BLUE wires.
3-SPEED ♦ OPTIONAL WALL CONTROL ♦ W-40
The W-40 wall control provides four-speed control of fan from a convenient wall location.
The W-40 is designed to replace a standard wall switch and will fit wall boxes with a depth
of 2" or greater. Not for use with single pull-chain fan/ light option wiring.
To install a W-40 wall control in place of an existing wall switch, follow the instructions on
the W-40 package.
Note: No rewiring is required if the fan is replacing an existing light fixture.
Operation of the fan from the wall switch is simple:
1. Turn knob to obtain desired speed setting.
CAUTION! Failure to set the pull-chain speed to HIGH can result in faulty operation of
the fan and damage to the W-40 wall control. To confirm fan is set to HIGH: Turn W-40
fan speed switch to 'HI' - set fastest fan speed with pull chain.
3-SPEED ♦ OPTIONAL WALL CONTROL ♦ W-80
The W-80 wall control provides separate control of fan and light with two separate knobs
from a convenient wall location. The W-80 is designed to replace a standard wall switch and
wall boxes with a depth of 2" or greater. Requires two hot leads from wall box to ceiling
wiring box.
LO
To install a W-80 wall control in place of an existing wall switch, follow the instructions on
the W-80 package.
Operation of the fan from the wall switch is simple:
1. Turn the upper knob to the desired fan speed.
2. Turn the lower knob to the desired light setting.
CAUTION! Failure to set the pull-chain speed to HIGH can result in faulty operation of
the fan and damage to the W-80 wall control. To confirm fan is set to HIGH: Turn W-80
fan speed switch to 'HI' - set fastest fan speed with pull chain.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
3-SPEED ♦ W-40 WALL CONTROL OF THE FAN
• The W-40 allows the choice of four
(4) different speed settings.
• No light fixture is used.
• Set the FAN pull chain switch to the
HIGH speed setting.
• No changes in household or fan wiring
are required.
• The fan may be turned ON and OFF by
the W-40 wall control.
CAUTION! Failure to set the pull-chain
speed to HIGH can result in faulty
operation of the fan and damage to
the W-40 wall control. To confirm fan
is set to HIGH: Turn W-40 fan speed
switch to 'HI' - set fastest fan speed
with pull chain.
R
3-SPEED ♦ W-80 WALL CONTROL OF THE FAN & LIGHT(S)
• The fan may be turned ON and OFF
by the W-80 wall control.
• The lights may be turned ON and
OFF by the W-80 and the inten-
sity adjusted from low to high.
• The fan must be supplied with two
independent 120V AC supply
wires.
• Set the FAN pull chain switch to
the HIGH speed setting.
• Turn the lights ON at the fan.
• The W-80 allows the choice of four
(4) different speed settings.
CAUTION! Failure to set the pull-
chain speed to HIGH can result in
faulty operation of the fan and
damage to the W-80 wall control.
To confirm fan is set to HIGH: Turn
W-80 fan speed switch to 'HI' -
set fastest fan speed with pull
chain.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING
Before Requesting Service: Please follow this troubleshooting guide before contacting your dealer for assistance.
Caring for Finishes: For cleaning, a soft brush or lint-free cloth Never Lubricate this Fan!
should be used to prevent scratching the finish. A vacuum cleaner The precision motor at the heart of your Casablanca fan features
brush nozzle can remove heavier dust. Surface smudges or an accu- sealed bearings that are lubricated for life. Do not attempt to oil
mulation of dirt and dust can easily be removed by using a mild the motor.
detergent and slightly dampened soft cloth. An antistatic agent Changing Light Bulbs
may be used, but never use abrasive cleaning agents. These will Be sure to turn power to the fan OFF at the wall switch or circuit
damage the finish. Painted and high-gloss blades may be cleaned breaker before changing light bulbs. Replace bulbs with same type
in the same manner.
as removed from the fixture. Each fan is rated for a maximum TOTAL
Blades: Wood finish blades should be cleaned with a furniture pol- wattage of lighting.
ishing cloth. Occasionally, a light coat of furniture polish may be Exceeding the rated maximum allowable wattage for the fan will
applied for added protection and beauty.
burn out the fan electronics module and void the warranty.
PROBLEM
FAN WILL NOT START
3-SPEED
POSSIBLE REMEDIES..
Check main circuit fuses, circuit breakers, or wall switch position.
Check all wire connections, making sure the power is turned off during this inspection.
Check that reverse switch is not set in center of throw.
FAN WOBBLES OR SHAKES Be sure canopy pin is properly set into the slot on the ball.
EXCESSIVELY
Check the screws holding the blade holders to the flywheel (or direct drive motor). Tighten as necessary.
Check that bladeholders have not been bent during installation.
FAN NOISY DURING
OPERATION
Check and tighten light fixture retaining screws, glass shade screws and/ or the light bulb(s) as neccessary.
Tighten the blade to bladeholder screws.
Tighten canopy screws and mounting plate assembly.
Check and tighten blade holders to flywheel (or direct drive motor).
Make sure all screws in the motor housing are snug, but not overly tight.
Check that the wire nuts inside the canopy and switch housing are not touching the metal parts or have
fallen off the wire splices. Tighten or adjust as necessary.
BREAK-IN PERIOD
Let fan run at high speed for two (2) hours
DOES NOT RUN ON
LOW SPEED
If new, “break-in” may be required - run at higher speed for several days
FAN RUNS SLOWLY IN EITHER DIRECTION IF ROTATION IS STARTED BY HAND; WILL NOT REVERSE: Defective reverse switch; defective
capacitor; or open motor winding: Replace reverse switch assembly; replace PCB assembly; or replace motor unit.
FAN WILL NOT OPERATE AT PROPER SPEEDS OR WILL NOT OPERATE AT ANY SPEED: Defective three-speed pull-chain switch assembly; or
defective capacitor: Replace three-speed pull-chain switch assembly; or replace PCB assembly.
PERFORMANCE AND ENERGY INFORMATION
12
Download from Www.Somanuals.com. All Manuals Search And Download.
2
VERSA•TOUCH 2 ♦ INSTALLATION
W-72
CONTROL
HOLDER
DRYWALL
ANCHOR
6-32 (2)
WOOD
SCREW
1” (2)
SCREW
6-32 X 3/ 8”
(2)
SCREW
6-32 X 1”
(2)
W-72
CONTROL
12V BATTERY
VERSA•TOUCH 2 ♦ CONTROL BRACKET INSTALLATION
CAUTION! Do not use with wall dimmer.
STANDARD
TOGGLE
SWITCH
ROCKER
TYPE
LIGHT
SWITCH
INNER
MOUNTING
HOLES
OUTER
MOUNTING
HOLES
SWITCH
COVER
PLATE
SWITCH
COVER
PLATE
CONTROL
CONTROL
BRACKET
BRACKET
Standard Light Switch
Step A. Remove the two screws holding the switch cover
plate. Do not remove the cover plate.
Step B. Orient the control bracket as shown and line up the
two inner mounting holes with those on the switch.
Step C. Install and tighten screws by hand only.
Rocker Light Switch
Step A. Break off the two tabs by pushing outward.
Step B. Remove the two screws holding the switch cover
plate. Do not remove the cover plate.
Step C. Orient the control bracket as shown and line up the
two inner mounting holes with those on the switch.
Step D. Install and tighten screws by hand only.
Wall Installation
Note: The wall anchors and 6-32 x 1” screws may be
used in situations where mounting to a stud is not pos-
sible. Use the inner mounting holes. After securing the
anchor, discard the anchor’s pointed screws and use the
6-32 decor ovalhead screws supplied.
Step A. Locate a 2x4 wall
stud in a convenient
location.
Step B. Orient the control
bracket as shown over the
2x4 stud.
Step C. Use the 1” wood
screws in either the inner
or outer mounting holes.
Install and tighten screws
by hand only.
ANCHOR
PANHEAD
SCREW
DRYWALL ANCHOR
WOOD
SCREW 1”
DECOR OVALHEAD SCREW
6-32 X 1”
Changes or modifications not expressly ap-
proved in writing by Casablanca Fan Co. may
void the user’s authority to operate this
equipment.
This device complies with RSS-210 of Industry Canada. Operation is subject to
the following two conditions: (1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may
cause undesired operation of the device.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
2
VERSA•TOUCH 2 OPERATION
SEND SIGNAL
LED
Fan Control
LIGHT
To start the fan. Press the selected speed button to run the fan at the desired speed.
LO=Low speed MED=Medium speed HI=High speed
To turn off the fan. Press the FAN OFF button.
MED
LO
Airflow Direction
To reverse the airflow press the REVERSE button. Reverse operates at any speed whether fan
is on or off. The fan returns to its set speed after reversing.
Light Control
HI
Turn the light on or off independently from the fan by pressing the LIGHT button. Keep
pressing the button in excess of 0.7 seconds, it becomes a dimmer. The light varies from
‘bright’ to ‘dim’ over approximately 8 seconds. This sequence will reverse the light when it
reaches the brightest or dimmest level if you continue to hold the LIGHT button. Release the
button when the desired level is reached.
FAN
STOP
Auto Resume
REVERSE
Quick (pressing less than 0.7 seconds) on/ off operation of the LIGHT button maintains the
desired brightness level set previously.
VERSA•TOUCH 2 ♦ CHANGING FREQUENCY SETTING
Note: All fans leave the factory set to ‘00000’.
You will only have to change the dip switch settings in the remote if
you are using more than one fan in the same area and want to control
them separately.
VERSA•TOUCH 2
CONTROL
Step 1. At the circuit breaker or fuse box, turn the power off for the fan
you want to change.
(BACK)
Step 2. Open the battery door of the Versa•Touch control and remove
the batteries.
Step 3. Change the dip switch settings, assuring that they are different
from the previously installed Versa•Touch fan.
Step 4. Re-install the batteries and the battery door on the control.
DIP SWITCH
SET TO ‘10000’
DIP SWITCH
SET TO ‘01001’
Step 5. At the circuit breaker or fuse box, turn the power back on for
the fan whose frequency you are changing.
Step 6. Within 20 seconds of restoring power, push the Hi, Med, and Lo
buttons (in that order).
WITHIN 20 SECONDS OF
2
TURNING THE FAN ON,
PRESS IN THIS ORDER TO
SET NEW FREQUENCY:
1. HI
Note: You may want to label your controls to
assure you do not mix them up.
2. MED
3. LO
WARNING: Do not turn the power off at the circuit breaker,
then back on, for the previously installed Versa• Touch 2
fan(s), as you may inadvertantly change the frequency set-
tings for it as well.
3
1
VERSA•TOUCH 2 ♦ IF FAN DOES NOT WORK
If the fan is not functioning after installation:
2
Step 1. Check to make sure that batteries are installed correctly
in the control.
Step 2. Turn the power off to the fan (from the circuit breaker)
for at least 5 seconds.
3
1
Step 3. Turn the power back on (at the circuit breaker) and push
the Hi, Med, and Low buttons–in that order–within 20 seconds.
Step 4. The fan should now function properly.
PRESS IN THIS ORDER TO SET NEW
FREQUENCY:
CIRCUIT BREAKER
OR FUSE BOX
1. HI
2. MED
3. LO
14
Download from Www.Somanuals.com. All Manuals Search And Download.
2
TROUBLESHOOTING
VERSA•TOUCH 2
PROBLEM
PROBLEM
POSSIBLE REMEDIES
POSSIBLE REMEDIES..
Before Requesting Service: Please follow this troubleshooting guide before contacting your dealer for assistance.
FAN WILL NOT START
•Check main circuit fuses, circuit breakers, or wall switch position. Check all wire connections, making
sure the power is turned off during this inspection.
•Pin connectors are not making good contact. Check the connections in the switch housing and under the
top cover.
•Battery weak - install fresh battery.
•Fan receiver defective - replace.
•Check the frequency setting: Turn power off, at the circuit breaker, only for the fan not functioning for
at least 5 seconds; turn the power back on; within 20 seconds press the Hi, Med, and Lo buttons (in that
order) to set the frequency of the fan to the control.
FAN WOBBLES OR SHAKES •Be sure canopy pin is properly set into the slot on the ball.
EXCESSIVELY
•Check that bladeholders have not been bent during installation and blades are balanced.
•Hanger bracket and/ or ceiling outlet are loosely attached: Make sure that the hanger bracket is tightly.
attached to the ceiling outlet box. Make sure that the downrod assembly is secured firmly.
•Downrod is loosely attached to downrod base: Make sure that all screws are securely tightened .
FAN NOISY DURING
OPERATION
•Check and tighten light fixture retaining screws, glass shade screws and/ or the light bulb(s).
•Tighten canopy screws and mounting plate assembly. Check that the wire nuts inside the canopy and
switch housing are not touching the metal parts or have fallen off the wire splices. Tighten as necessary.
•Tighten blade holders to flywheel (or direct drive motor)/ and blade to bladeholder screws.
•Make sure all screws in the motor housing are snug, but not overly tight. Defective bulb: Replace bulb.
DOES NOT RUN ON
LOW SPEED
•If new, “break-in” may be required - run at higher speed for several days.
•Not using Alkaline batteries: Replace with Alkaline batteries.
BATTERY LIFE
SEEMS SHORT
• LIGHT O.K., NO FAN: Pin connectors are not making good contact, check 9 pin connector under top cover.
• FAN O.K., NO LIGHT; Defective receiver; Replace receiver. Defective motor; Replace motor. Broken socket; Replace socket. Defective receiver;
Replace Receiver.
• FAN AND LIGHT ON FULL, NO CONTROL; Defective receiver; Replace Receiver.
• MISSING ONE SPEED: Defective receiver; Replace Receiver.
• FAN DOESN’T CHANGE SPEED, LIGHT O.K.: Replace receiver.
• FAN O.K., LIGHT NOT DIM: Defective receiver; Replace Receiver.
• NO REVERSE: Defective receiver; Replace Receiver.
• FAN OPERATES ONLY WHEN TRANSMITTER IS CLOSED: Check antenna wire is not touching metal plate.
• FAN STARTS WORKING BY ITSELF: Frequency interference; Change frequency as described on Page 2.
For questions or to locate the nearest
Casablanca Authorized Service Center
call toll free:
1-888-227-2178
or visit us on the web at:
www.CasablancaFanCo.com
15
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT SPECIFICATIONS
188mm x 20mm Direct Drive™
45" or 53"
16°
5
®
Model Name:
Capistrano
Motor:
Model Number: 46XXD/M and 46UXXD/M
Blade Span With:
Blade Pitch:
Dimensions:
A =
B = 12.75"
C = 3"
11.1"
No. of Blades:
Technology:
3-Speed
NOTE: Dimension B
includes light fixture
and glass.
®
Versa•Touch2 W-72
D = 12.6"
E =
5.6"
Airflow:
6,691 cfm
89 watts
Electricity Use*:
Weight:
21 lbs.
Airflow Efficiency*: 75 cfm/watt
* Performance data is for fan only. No lighting wattage is included.
Measurements taken with 21" blades.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
|