Carrier Heat Pump 50XT User Manual

50XT  
Infinity 15t SEER Single---Packaged Heat Pump System  
with Puronr (R---410A) Refrigerant  
Single Phase  
2---5 Nominal Tons (Sizes 024---060)  
Product Data  
Comfort Heat Pump System with IdealHumidityt featuring  
Infinityt control variable--speed blower motor and two--stage  
cooling and heating that provides greater comfort, humidity  
control, and energy efficiency.  
Variable--speed blower motors provide better comfort and energy  
efficiency. You can expect up to 30 times better dehumidification;  
economical constant airflow which provides improved indoor air  
quality and more even temperatures from room to room; and  
reduced indoor noise due to lower air velocity. In addition, you’ll  
realize improved installation flexibility with 3 different airflow  
choices for best overall comfort.  
Easy installation  
Factory--assembled package is a compact, fully self--contained heat  
pump unit that is pre--wired, pre--piped, and pre--charged for  
minimum installation expense. 50XT units are available in a  
variety of standard capacity ranges. Units install easily on a rooftop  
or at ground level.  
Durable, dependable components  
Compressors have two stages of cooling and heating and are  
designed for high efficiency. Each compressor is hermetically  
sealed against contamination to help promote longer life and  
dependable operation. Vibration isolation provides quiet operation.  
Compressors have internal high--pressure and overcurrent  
protection.  
A05307  
Fig. 1 -- Unit 50XT  
Convertible duct configuration  
Single--Packaged Products with energy--saving features and  
Puron refrigerant.  
S Up to 15.5 SEER  
Unit is designed for easy use in either downflow or horizontal  
applications. Each unit is easily converted from horizontal to  
downflow with two duct covers (available as an accessory).  
Downflow operation is easily provided in the field to allow vertical  
ductwork connections. The basepan utilizes knockout style seals  
on the bottom openings to ensure a positive seal in the horizontal  
airflow mode.  
®
S Up to 8.0 HSPF  
S Up to 12 EER at 95°F (35°C) OD  
S Low Sound Levels  
S Variable--Speed Blower (Standard)  
S Factory--Installed TXV  
Direct--drive, variable--speed blower motor is standard on all  
50XT models.  
S Two--stage cooling and heat pump operation  
Direct--drive, PSC condenser fan motors are designed to help  
reduce energy consumption and provide for cooling operation  
down to 55°F (12.7°C) outdoor temperature. Low--ambient  
cooling is available below 55°F (12.7°C) when low--ambient  
FEATURES/BENEFITS  
One--piece Heat Pump unit with optional electric heater, low  
installation cost, dependable performance and easy maintenance.  
®
cooling is enabled in the User Interace (UI). Motormaster II  
low--ambient kit is not required.  
Infinityt User Interface is designed to work as a system with  
Carrier’s single--packaged product.  
Refrigerant system is designed to provide dependability. Liquid  
refrigerant filter driers are used to promote clean, unrestricted  
operation. Each unit leaves the factory with a full Puron refrigerant  
charge. Refrigerant service connections make checking operating  
pressures easier.  
Efficient operation  
High--efficiency design with SEERs (Seasonal Energy Efficiency  
Ratio) of up to 15.5.  
®
Puron environmentally--sound refrigerant is Carrier’s unique  
refrigerant designed to help protect the environment. Puron is an  
HFC refrigerant which does not contain chlorine that can harm the  
ozone layer. Puron refrigerant is in service in millions of systems  
proving highly reliable, environmentally sound performance.  
Indoor and outdoor coils are computer designed for optimum  
heat transfer and cooling efficiency. The indoor coil is fabricated  
from copper tube and aluminum fins and is located inside the unit  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL NUMBER NOMENCLATURE  
50XT  
024  
– – –  
3
0
1
– –  
Options  
BT - AL evap, vinyl condens  
CC - AL evap, CU condens  
CU - CU evap & condens  
TP - Base unit with tin plated  
indoor coil hairpins  
Type of Unit  
50XT - Packaged  
Electric Heat Pump  
TV - TP with vinyl coating on outdoor coil  
TC - TP with AL indoor coil and  
CU/CU outdoor coil  
Nominal Cooling Capacity  
024 - 2 Ton  
030 - 2.5 Ton  
036 - 3 Ton  
042 - 3.5 Ton  
048 - 4 Ton  
Only used if ordering an option  
060 - 5 Ton  
Packaging  
N/A  
Series  
LEGEND  
Electrical Supply  
AL - Aluminum  
CU - Copper  
3- 208/230-1-60  
ARI* CAPACITIES  
Cooling Capacities and Efficiencies  
UNIT  
50XT  
NOMINAL  
TONS  
STANDARD CFM (High/Low Stage)  
(Cooling & Heating)  
NET COOLING CAPACITIES (Btuh)  
(High/Low Stage)  
SEER‡  
EER @A{  
024  
030  
036  
042  
048  
060  
2
2--1/2  
3
3--1/2  
4
800 / 600  
1000 / 700  
1200 / 850  
1500 / 975  
1600 / 1100  
1750 / 1200  
22,600 / 17,600  
28,600 / 21,400  
34,600 / 24,400  
40,500 / 29,000  
46,000 / 33,400  
57,000 / 40,500  
11.4  
11.6  
12  
11.6  
11  
15.5  
15.0  
15.0  
15.0  
15.0  
14.5  
5
11  
Heating Capacities and Efficiencies  
HIGH HEAT CAPACITY  
(BTUH) @ 47°F (8.3°C)  
(High/Low Stage)  
HIGH HEAT COP  
LOW HEAT CAPACITY  
(BTUH) @ 17°F (-8.3°C)  
(High/Low Stage)  
LOW HEAT COP  
@ 17°F (-8.3°C)  
(High/Low Stage)  
UNIT  
50XT  
@ 47°F (8.3°C)  
(High/Low Stage)  
HSPF‡  
024  
030  
036  
042  
048  
060  
20,800 / 16,800  
27,600 / 20,400  
33,600 / 23,000  
39,500 / 27,600  
45,500 / 32,200  
56,000 / 39,500  
3.3 / 3.2  
3.5 / 3.5  
3.4 / 3.4  
3.6 / 3.5  
3.3 / 3.5  
3.2 / 3.3  
11,600 / 8,400  
14,000 / 9,600  
17,200 / 11,200  
20,600 / 14,200  
25,000 / 15,200  
30,800 / 20,400  
2.2 / 1.8  
2.1 / 1.9  
2.4 / 1.7  
2.3 / 2.0  
2.4 / 1.9  
2.2 / 1.9  
8.0  
8.0  
8.0  
8.0  
8.0  
8.0  
{ Aconditions---80°F (26.6°C) indoor db/67°F (19.4°C) indoor wb & 95°F (35°C) outdoor db.  
}
Rated in accordance with U.S. Government DOE (Department of Energy) test procedures and/or ARI Standards 210/240.  
** Tested in accordance with ARI Standard 270---95 (not listed in ARI).  
NOTES:  
1. Ratings are net values, reflecting the effects of circulating fan heat. Ratings are based on:  
Cooling Standard: 80°F (26.6°C) db, 67°F (19.4°C) wb indoor entering ---air temperature and 95°F (35°C) db outdoor entering---air temperature.  
2. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer.  
LEGEND  
dBA—Sound Levels (decibels)  
db—Dry Bulb  
SEER—Seasonal Energy Efficiency Ratio  
wb—Wet Bulb  
COP—Coefficient of Performance  
HSPF—Heating Season Performance Factor  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
PHYSICAL DATA  
UNIT SIZE  
024  
2
405  
184  
030  
2 --- 1/2  
435  
036  
3
464  
210  
042  
3 --- 1/2  
476  
048  
4
492  
223  
060  
5
535  
243  
NOMINAL CAPACITY (ton)  
OPERATING WEIGHT (lb)  
(kg)  
197  
216  
COMPRESSOR  
Two --- Stage Scr ol l  
REFRIGERANT: PURON (R---410A) Quantity (lb)  
10.3  
4.7  
11.5  
5.2  
9.7  
4.4  
14.0  
6.4  
15.5  
7.0  
16.0  
7.3  
(kg)  
EXPANSION DEVICE---HEATING  
ORIFICE OD (in.) --- Left  
ORIFICE OD (in.) --- Right  
AccuRater  
0.038  
0.038  
0.035  
0.035  
0.040  
0.042  
0.038  
0.046  
0.046  
0.046  
0.042  
EXPANSION DEVICE---COOLING  
Size  
TXV  
2 Ton  
3 Ton  
3 Ton  
4 Ton  
4 Ton  
5 Ton  
Part Number  
EA36YD129  
EA36YD139  
EA36YD139  
EA36YD149  
EA36YD149  
EA36YD159  
OUTDOOR COIL  
RowsFins/in.  
Face Area (sq. ft.)  
OUTDOOR FAN  
Nominal Cfm  
221  
13.6  
221  
15.3  
221  
17.5  
221  
19.4  
221  
19.4  
221  
23.3  
2700  
22  
559  
2700  
22  
559  
2800  
22  
559  
2800  
22  
559  
3300  
22  
559  
3300  
22  
559  
Diameter (in.)  
(mm)  
Motor HP (RPM)  
INDOOR COIL  
RowsFins/in.  
Face Area (sq. ft.)  
INDOOR FAN  
Nominal Airflow (Cfm)  
Comfort  
1/8 (825)  
1/8 (825)  
1/8 (825)  
1/8 (825)  
1/4 (1100)  
1/3 (1110)  
317  
3.7  
317  
3.7  
317  
4.7  
317  
4.7  
317  
5.7  
417  
5.7  
Variable based on Comfort Settings (see User Interface instructions for more information).  
Efficiency  
Max  
700  
800  
875  
1000  
1050  
1200  
1225  
1400  
1400  
1600  
1750  
2000  
Size (in.)  
10x10  
254x254  
10x10  
254x254  
11x10  
279x254  
11x10  
279x254  
11x10  
279x254  
11x10  
279x254  
(mm)  
Motor HP (RPM)  
1/2  
1/2  
3/4  
3/4  
3/4  
1
HIGH---PRESSURE SWITCH (psig)  
Cutout  
670 ± 10  
Reset (Auto)  
470 ± 25  
HIGH---PRESSURE SWITCH 2 (psig)  
(Compressor Solenoid)  
Cutout  
565 ± 15  
455 ± 15  
Reset (Auto)  
LOS S --- OF --- CHARGE /LOW --- PRE S SU RE SWIT C H  
(Liquid Line) (psig)  
Cutout  
Reset (Auto)  
23 ± 5  
55 ± 5  
RETURN---AIR FILTERS Throwaway (in.)*  
(mm)  
20x24x1  
508x610x25  
24x30x1  
610x762x25  
24x36x1  
610x914x25  
*Recommended filter sizes for field---installed air filter grilles mounted on the wall or ceiling of the conditioned structure. Required filter sizes shown are based  
on the larger of the ARI (Air Conditioning and Refrigeration Institute) rated cooling airflow or the heating airflow velocity of 300 ft/minute for throwaway type or  
450 ft/minute for high---capacity type. Air filter pressure drop for non---standard filters must not exceed 0.08 IN. WC.  
ISO 9001:2000  
REGISTERED  
A--WEIGHTED SOUND POWER LEVEL (dBA)  
STANDARD  
RATING  
(dBA)  
TYPICAL OCTAVE BAND SPECTRUM (dBA) (without tone adjustment)  
MODEL 50XT  
125  
250  
500  
1000  
2000  
4000  
8000  
024  
030  
036  
042  
048  
060  
75  
75  
75  
75  
78  
78  
58.8  
58.8  
60.7  
56.7  
62.4  
63.5  
63.5  
63.5  
63.3  
62.8  
69.9  
67.6  
67.2  
67.2  
66.8  
67.8  
71.3  
71.8  
66.9  
66.9  
66.5  
67.4  
73.4  
75.5  
63.7  
63.7  
64.2  
63.7  
70.0  
71.0  
58.3  
58.3  
60.3  
57.7  
66.3  
68.1  
50.0  
50.0  
53.0  
50.8  
60.1  
59.9  
NOTE: Tested in accordance with ARI Standard 270---95 (not listed in ARI).  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPTIONS AND ACCESSORIES  
Factory--installed options  
compartment. Heater sizes range from 5.0 to 20.0 kW. The electric  
heater design allows the use of a single--point power supply for the  
entire unit, resulting in lower installed costs.  
Coil options include tin--plated* indoor hairpins, copper/copper  
and vinyl--coated construction for refrigerant coils. Units are  
shipped standard with copper tube/aluminum fin construction. See  
model number nomenclature for coil options.  
Flat roof curbs in both 8 in. (203 mm) and 14 in. (256 mm) sizes  
are available for roof mounted applications.  
*Tin--plated indoor coils are built with special hairpins that are  
designed to resist both general pitting corrosion and excessive  
indoor corrosion (Formicary Corrosion).  
Square--to--round duct transition kit enables 024--048 size units  
to be fitted to 14 in. round ductwork.  
Infinity User Interface coupled with the system’s variable--speed  
indoor blower delivers Carrier’s patented IdealHumidity  
technology that allows for even greater humidity control. Along  
with more precisely controlling temperature and humidity, the  
Infinity User Interface offers full seven--day programmability  
allowing you to further customize your comfort and energy  
savings.  
Field--installed accessories  
Manual Air Damper (25% open)  
Electric Heaters  
Filter Rack  
Flat Roof Curbs (8--in. and 14--in.) (203 mm and 256 mm)  
Square--to--Round Duct Transition Kit  
Infinityt User Interface  
Crankcase Heater  
Lifting Kit  
Lifting kit includes 4 metal brackets that are available to assist in  
lifting this product onto a roof application.  
Crankcase heater  
provides anti--floodback protection for  
low--load cooling applications.  
Compressor Hard Start Kit  
Filter rack  
features easy installation, serviceability, and  
high--filtering performance for vertical or horizontal applications.  
Manual outside air damper includes hood and filter rack with  
adjustable damper blade for up to 25% outdoor air.  
Electric heaters provide additional heat in the unit when required.  
Each package has a heater module that slides into the controls  
Compressor hard start kit assists compressor start--up by  
providing additional starting torque on single phase units and  
prolongs compressor motor life.  
Electric Heaters  
NOMINAL  
USED WITH SIZES  
CATALOG  
ORDERING NO.  
CAPACITY  
(kW)  
FUSED  
STAGES  
24  
30  
36  
42  
48  
60  
208/240 — SINGLE PHASE (60 Hz)  
CPHEATER080A00  
CPHEATER081A00  
CPHEATER083A00  
CPHEATER085A00  
CPHEATER087A00  
CPHEATER089A00  
NOTE  
3.8 / 5.0  
3.8 / 5.0  
NO  
YES  
YES  
YES  
YES  
YES  
1
1
1
1
2
2
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
5.4 / 7.2  
X
X
X
X
X
X
X
X
7.5 / 10.0  
11.3 / 15.0  
15.0 / 20.0  
Electric heaters are rated at 240v. Refer to Multiplication Factors table for other voltages.  
X=Approved combination  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
FILTER RACK  
MANUAL OUTSIDE AIR DAMPER  
BEND FLANGE AT 90°-SCREW TO  
DIVIDER WITH 1-IN. SCREW  
REPLACEMENT  
PANEL  
MANUAL OUTSIDE  
AIR HOOD  
TOP FILTER RACK  
EVAPORATOR  
COIL  
DAMPER  
BLADE  
BOTTOM FILTER  
RACK  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORY DIMENSIONS  
HVACunit  
base  
HVAC unit  
base  
Gask eting  
inner flange*  
Screw  
(NOTE A)  
Screw  
(NOTE A)  
Gasketing  
inner flange*  
*Gasketing  
outer flange  
*Gasketing  
outer flange  
Wood nailer*  
Wood nailer*  
Flashing field  
supplied  
Flashing field  
supplied  
Roof curb*  
Roof curb*  
Insulation(field  
supplied)  
Insulation(field  
supplied)  
Roofing material  
field supplied  
Roofing material  
field supplied  
Ductwork  
field supplied  
Ductwork  
field supplied  
Cant strip  
field supplied  
Cant strip  
field supplied  
Roof  
Roof  
*Provided with roof curb  
*Provided with roof curb  
Roof Curb for Small Cabinet  
Roof Curb for Large Cabinet  
Note A: When unit mounting screw is used,  
retainer bracket must also be used.  
Note A: When unit mounting screw is used,  
retainer bracket must also be used.  
E
G
F
Supply opening  
(B x C)  
G
BTyp.  
D
CTyp.  
F
R/A  
S/A  
A
Gasket around  
duct  
D
E
Short  
Support  
Insulated  
deck pan  
Gasket around  
outer edge  
Insulated  
deck pan  
Long  
Support  
Return opening  
(B X C)  
A05308  
CATALOG  
NUMBER  
A
B
C
D
E
F
G
UNIT SIZE  
024-030  
036-060  
IN. (MM)  
IN. (MM)  
IN. (MM)  
IN. (MM)  
IN. (MM)  
IN. (MM)  
IN. (MM)  
CPRFCURB006A00  
CPRFCURB007A00 14 (356)  
CPRFCURB008A00  
CPRFCURB009A00 14 (356) 16--3/16 (411) 17--3/8 (441) 40--1/4 (1022) 41--15/16 (1065) 44--7/16 (1129)  
8 (203)  
11 (279)  
11 (279)  
16--1/2 (419)  
16--1/2 (419)  
28--3/4 (730)  
28--3/4 (730)  
30--3/8 (771)  
30--3/8 (771)  
44--5/16 (1126) 45--15/16 (1167)  
44--5/16 (1126) 45--15/16 (1167)  
8 (203) 16--3/16 (411) 17--3/8 (441) 40--1/4 (1022) 41--15/16 (1065) 44--7/16 (1129)  
46--1/16 (1169)  
46--1/16 (1169)  
NOTES:  
1. Roof curb must be set up for unit being installed.  
2. Seal strip must be applied, as required, to unit being installed.  
3. Roof curb is made of 16--gauge steel.  
4. Attach ductwork to curb (flanges of duct rest on curb).  
5. Insulated panels: 1--in. (25 mm) thick fiberglass 1 lb. density.  
6. When unit mounting screw is used (see Note A), a retainer bracket must be used as well. This bracket must also be used when required by code for hurricane or seismic  
conditions. This bracket is available through Micrometl.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
50XT SUGGESTED RIGGING  
-in. (914 mm)  
DETAIL  
A
A06296  
RIGGING WT  
lb  
CABINET  
MODEL  
A06298  
kg  
50XT--024  
50XT--030  
418  
448  
190  
203  
Small  
50XT--036  
50XT--042  
50XT--048  
50XT--060  
469  
491  
497  
548  
213  
223  
225  
249  
Large  
NOTE: See dimensional drawing for corner weight distribution. Corner  
weights shown on drawing are based on unit---only weights and do  
not include packaging.  
SELECTION PROCEDURE  
Enter the Electric Heater table on page  
5
for 208/230v,  
Determine cooling and heating requirements at design  
single--phase, unit. The 7.2--kW heater at 240v most closely  
satisfies the heating required. To calculate kW at 230v, multiply the  
heater kW by multiplication factor 0.92 found in the Multiplication  
Factors table on page 29.  
conditions  
Given:  
REQUIRED COOLING CAPACITY (TC) . . . . . . 34,500 BTUH  
SENSIBLE HEAT CAPACITY (SHC) . . . . . . . . . 24,000 BTUH  
7.2 kW x 0.92 = 6.6 kW  
REQUIRED HEATING CAPACITY (SHC) . . . . . 36,000 BTUH  
CONDENSER ENTERING AIR TEMPERATURE 95°F (35°C)  
INDOOR--AIR TEMPERATURE . . . 80°F (26.6°C) EDB, 67°F  
(19.4°C) EWB  
6.6 kW x 3414 Btuh/kW = 22,532 Btuh  
Total unit heating capacity is 39,342 Btuh  
(16,810 + 22,532).  
EVAPORATOR AIR QUANTITY . . . . . . . . . . . . . . . 1200 CFM  
ELECTRICAL CHARACTERISTICS . . . . . . . . . . . . . 230--1--60  
Select unit that corresponds to power source available  
The Electrical Data table shows that the unit is designed to operate  
at 208/230--1--60.  
Select unit based on required cooling capacity  
Enter Net Cooling Capacities table at condenser entering  
temperature of 95°F (35°C). The 036 unit at 1200 cfm and 67°F  
(19.4°C) ewb (entering wet bulb) will provide a total capacity of  
34,600 Btuh and a SHC of 24,220 Btuh. Calculate SHC correction,  
if required, using Note 4 under Cooling Capacities tables.  
Select electric heat  
Enter the 036 unit Heating Extended Performance table at 1200  
cfm. At 70°F (21.1°C) return indoor air and 20°F (--6.6°C) air  
entering outdoor coil, the integrated heating capacity is 16,810  
Btuh. (Select integrated heating capacity value since deductions for  
outdoor--coil frost and defrosting have already been made. No  
correction is required.)  
The required heating capacity is 36,000 Btuh. Therefore, at least  
19,190 Btuh additional electric heat is required.  
Determine additional electric heat capacity in kW.  
19,190 Btuh  
3414 Btuh/kW  
= 5.6kW of heat required  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PERFORMANCE DATA (CONT)  
Multiplication Factors  
Heater kW  
Rating  
Voltage Distribution  
V/3/60  
Example: 15.0 kW (at 240v) heater on 208v  
= 15.0 (.75 mult factor)  
Multiplication Factor  
= 11.25 capacity at 208v  
200  
208  
230  
240  
.69  
.75  
.92  
240  
Sensible capacity (Btuh)  
1.10 x cfm  
1.00  
LEGEND  
BF— Bypass Factor  
edb— Entering Dry--Bulb  
Ewb— Entering Wet--Bulb  
kW — Total Unit Power Input  
ldb— Leaving Dry--Bulb  
t
t
t
--  
ldb = edb  
Wet---bulb temperature corresponding to enthalpy  
lwb =  
h
air leaving evaporator coil ( lwb)  
total capacity (Btuh)  
lwb— Leaving Wet--Bulb  
SHC— Sensible Heat Capacity (1000 Btuh)  
TC — Total Capacity (1000 Btuh) (net)  
h
h
lwb = e w b ---  
4.5 x cfm  
h
Where: ewb = Enthalpy of air entering evaporator coil  
4. The SHC is based on 80_F (26.6_C) edb temperature of air  
entering evaporator coil. Below 80_F (26.6_C) edb, subtract (corr  
factor x cfm) from SHC.  
*At 75°F (23.8°C) entering dry bulb (Tennessee Valley Authority  
[TVA] rating conditions); all other at 80°F (26.6°C) entering dry  
bulb.  
COOLING NOTES:  
1. Ratings are net; they account for the effects of the evaporator  
fan motor power and heat.  
Above 80_F (26.6_C) edb, add (corr factor x cfm) to SHC.  
Correction Factor = 1.10 x (1 + BF) x (edb + 80).  
5. Integrated capacity is maximum (instantaneous) capacity less the  
effect of frost on the outdoor coil and the heat required to defrost it.  
2. Direct interpolation is permissible. Do not extrapolate.  
3. The following formulas may be used:  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wet coil air delivery -- low stage  
208/230 VOLT  
EXTERNAL STATIC PRESSURE (in. wc)  
0.4 0.5 0.6 0.7  
Variable based on Comfort Settings  
UNIT  
SYSTEM SETTING  
SIZE  
0.1  
0.2  
0.3  
0.8  
0.9  
1.0  
COMFORT (Default)  
EFFICIENCY  
MAX  
COMFORT (Default)  
EFFICIENCY  
MAX  
COMFORT (Default)  
EFFICIENCY  
MAX  
COMFORT (Default)  
EFFICIENCY  
MAX  
COMFORT (Default)  
EFFICIENCY  
MAX  
COMFORT (Default)  
EFFICIENCY  
MAX  
525  
600  
525  
600  
525  
600  
525  
600  
525  
600  
525  
600  
525  
600  
525  
600  
525  
600  
525  
600  
024  
030  
036  
042  
048  
060  
Variable based on Comfort Settings  
613  
700  
Variable based on Comfort Settings  
743  
850  
Variable based on Comfort Settings  
853  
975  
Variable based on Comfort Settings  
963  
613  
700  
613  
700  
613  
700  
613  
700  
613  
700  
613  
700  
613  
700  
613  
700  
613  
700  
743  
850  
743  
850  
743  
850  
743  
850  
743  
850  
743  
850  
743  
850  
743  
850  
743  
850  
853  
975  
853  
975  
853  
975  
853  
975  
853  
975  
853  
975  
853  
975  
853  
975  
853  
975  
963  
1100  
963  
1100  
963  
1100  
963  
1100  
963  
1100  
963  
1100  
963  
1100  
963  
1100  
963  
1100  
1100  
Variable based on Comfort Settings  
1200  
1372  
1200  
1372  
1200  
1372  
1200  
1372  
1200  
1372  
1200  
1372  
1200  
1372  
1200  
1372  
1200  
1372  
1200  
1372  
Wet coil air delivery -- high stage  
208/230 VOLT  
EXTERNAL STATIC PRESSURE (in. wc)  
0.4 0.5 0.6 0.7  
Variable based on Comfort Settings  
UNIT  
SYSTEM SETTING  
SIZE  
0.1  
0.2  
0.3  
0.8  
0.9  
1.0  
COMFORT (Default)  
EFFICIENCY  
MAX  
COMFORT (Default)  
EFFICIENCY  
MAX  
COMFORT (Default)  
EFFICIENCY  
MAX  
COMFORT (Default)  
EFFICIENCY  
MAX  
COMFORT (Default)  
EFFICIENCY  
MAX  
COMFORT (Default)  
EFFICIENCY  
MAX  
700  
800  
700  
800  
700  
800  
700  
800  
700  
800  
700  
800  
700  
800  
700  
800  
700  
800  
700  
800  
024  
030  
036  
042  
048  
060  
Variable based on Comfort Settings  
875  
1000  
Variable based on Comfort Settings  
1050  
1200  
Variable based on Comfort Settings  
1225  
1400  
Variable based on Comfort Settings  
1400  
1600  
Variable based on Comfort Settings  
1750  
2000  
875  
1000  
875  
1000  
875  
1000  
875  
1000  
875  
1000  
875  
1000  
875  
1000  
875  
1000  
875  
1000  
1050  
1200  
1050  
1200  
1050  
1200  
1050  
1200  
1050  
1200  
1050  
1200  
1050  
1200  
1050  
1200  
1050  
1200  
1225  
1400  
1225  
1400  
1225  
1400  
1225  
1400  
1225  
1400  
1225  
1400  
1225  
1400  
1225  
1400  
1225  
1400  
1400  
1600  
1400  
1600  
1400  
1600  
1400  
1600  
1400  
1600  
1400  
1600  
1400  
1600  
1400  
1600  
1400  
1600  
1750  
2000  
1750  
2000  
1750  
2000  
1750  
2000  
1750  
2000  
1750  
2000  
1750  
2000  
1750  
2000  
1750  
2000  
Air delivery values are based on operating voltage of 230v, and wet coil. Filter and electric heater will not change air delivery values.  
NOTES:  
1. See User Interface instructions for more information on Max, Efficiency, and Comfort Settings  
2. Efficiency Setting operates at 350 cfm/ton (nominal) and Max Setting operates at 400 cfm/ton (nominal)  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TYPICAL PIPING AND WIRING  
ROOF-MOUNTING  
CURB  
ROOF  
RETURN-AIR  
FLEXIBLE DUCT  
SUPPLY-AIR  
FLEXIBLE DUCT  
CEILING  
CONCENTRIC DIFFUSER BOX  
(FIELD-SUPPLIED)  
C00023  
USER  
INTERFACE  
RETURN  
AIR  
FROM  
POWER  
SOURCE  
TOP COVER  
DISCONNECT  
PER NEC*  
*NEC - NATIONAL ELECTRICAL CODE  
A06279  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To convert a unit to downflow discharge — Units are equipped  
with factory--installed inserts in the downflow openings. Remove the  
inserts similar to removing an electrical knock--out. Leave on duct  
covers to seal the horizontal discharge openings in the unit. Units  
installed in horizontal discharge orientation do not require duct cov-  
ers.  
APPLICATION DATA  
Condensate trap — A 2--in. (51 mm) condensate trap must be field  
supplied.  
1” (25mm) MIN.  
TRAP  
OUTLET  
Minimum cooling ambient operating temperature — All stan-  
dard units have a minimum ambient operating temperature of 55°F  
(12.7°C). With low--ambient cooling enabled at the UI, units can op-  
erate at temperatures down to 0°F (--17.7°C).  
2” (50mm) MIN.  
Maximum operating outdoor air temperature — Maximum out-  
door operating air temperature for cooling is 125°F (51.6°C).  
Ductwork — Secure downflow dischargeductwork toroof curb.For  
horizontal discharge applications, attach ductwork to unit with  
flanges.  
Balance Point Worksheet  
70  
60  
50  
40  
30  
20  
10  
0
Based on Entering Indoor Air of 70 Deg. F and Rated CFM  
060  
048  
042  
036  
030  
024  
-20  
-10  
0
10  
20  
30  
40  
50  
60  
Outdoor Air Temp (Deg F)  
C03008  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTRICAL DATA  
SINGLE POINT POWER  
SUPPLY  
ELECTRIC HEAT  
VOLTAGE  
RANGE  
COMPRESSOR  
OFM  
FLA  
IFM  
FLA  
UNIT SIZE  
024  
V--PH--HZ  
NOMINAL  
kW*  
-- / --  
FLA  
MCA  
MOCP  
MIN  
MAX  
RLA  
LRA  
-- / --  
24.3/24.3  
46.9/50.3  
56.8/61.8  
69.4/76.4  
26.2/26.2  
48.7/52.2  
58.7/63.7  
71.3/78.3  
93.9/104.3  
28.6/28.6  
51.2/54.6  
61.1/66.1  
73.7/80.7  
96.3/106.7  
34.9/34.9  
57.5/60.9  
67.4/72.4  
80.0/87.0  
102.6/113.0  
125.2/139.1  
43.1/43.1  
65.7/69.1  
75.6/80.6  
88.2/95.2  
110.8/121.2  
133.4/147.3  
45.2/45.2  
67.7/71.2  
77.6/82.7  
90.3/97.2  
112.9/123.3  
135.4/149.3  
35/35  
50/60  
60/70  
70/80  
40/40  
50/60  
60/70  
80/80  
100/110  
45/45  
60/60  
70/70  
80/90  
100/110  
50/50  
60/70  
70/80  
90/90  
110/125  
150/150  
60/60  
70/70  
80/90  
90/100  
125/125  
150/150  
60/60  
70/80  
80/90  
3.8/5.0  
5.4/7.2  
7.5/10.0  
-- / --  
18.1/20.8  
26.0/30.0  
36.1/41.7  
-- / --  
208/230--1--60  
187  
187  
253  
253  
15.3  
52.0  
0.9  
0.9  
4.3  
4.3  
3.8/5.0  
5.4/7.2  
7.5/10.0  
11.3/15.0  
-- / --  
18.1/20.8  
26.0/30.0  
36.1/41.7  
54.2/62.5  
-- / --  
030  
036  
208/230--1--60  
208/230--1--60  
16.8  
16.7  
70.0  
82.0  
3.8/5.0  
5.4/7.2  
7.5/10.0  
11.3/15.0  
-- / --  
18.1/20.8  
26.0/30.0  
36.1/41.7  
54.2/62.5  
-- / --  
187  
187  
253  
253  
0.9  
0.9  
6.8  
6.8  
3.8/5.0  
5.4/7.2  
7.5/10.0  
11.3/15.0  
15.0/20.0  
-- / --  
18.1/20.8  
26.0/30.0  
36.1/41.7  
54.2/62.5  
72.2/83.3  
-- / --  
042  
048  
060  
208/230--1--60  
208/230--1--60  
208/230--1--60  
21.8  
27.8  
27.3  
96.0  
96.0  
3.8/5.0  
5.4/7.2  
7.5/10.0  
11.3/15.0  
15.0/20.0  
-- / --  
18.1/20.8  
26.0/30.0  
36.1/41.7  
54.2/62.5  
72.2/83.3  
-- / --  
187  
187  
253  
253  
1.5  
1.9  
6.8  
9.1  
3.8/5.0  
5.4/7.2  
7.5/10.0  
11.3/15.0  
15.0/20.0  
18.1/20.8  
26.0/30.0  
36.1/41.7  
54.2/62.5  
72.2/83.3  
118.0  
100/110  
125/125  
150/150  
*Heater capacity (kW) based on heater voltage of 208v & 240v. If power distribution voltage to unit varies from rated heater voltage, heater kW will vary accord-  
ingly.  
LEGEND  
FLA  
Full Load Amps  
LRA  
Locked Rotor Amps  
®
MCA  
MOCP  
RLA  
Minimum Circuit Amps  
Maximum Overcurrent Protection  
Rated Load Amps  
NOTES:  
1. In compliance with NEC (National Electrical Code) requirements  
for multimotor and combination load equipment (refer to NEC  
Articles 430 and 440), the overcurrent protective device for the  
unit shall be Power Supply fuse. The CGA (Canadian Gas  
Association) units may be fuse or circuit breaker.  
2. Minimum wire size is based on 60 C copper wire. If other than  
60 C wire is used, or if length exceeds wire length in table,  
determine size from NEC.  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TYPICAL WIRING SCHEMATIC — 230--1--60  
A08201  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
satisfied, the compressor will shut off. The reversing valve will  
remain energized until the control board power is removed or a call  
for heating is initiated. With a call for heating, the outdoor fan and  
compressor are energized. The compressor will operate in high or  
low stage operation, as needed, to meet the heating demand. When  
the heating demand is satisfied, the compressor and fan will shut  
off. The reversing valve is de--energized in the heating mode.  
CONTROLS  
Sequence of Operation  
The 50XT packaged heat pump is designed for installation with a  
communicatingUI. Thisunit willnot respondto commandsprovided  
by a common thermostat except under certain emergency situations.  
The UI uses temperature, humidity and other data supplied from  
indoor and outdoor system components to control heating or cooling  
system for optimum comfort. The unit will be commanded by the UI  
to supply airflow. The unit will operate the indoor fan at requested  
airflow for most modes.  
NOTE: When two--stage unit is operating at low--stage, system  
vapor (suction) pressure will be higher than a standard single--stage  
system or high--stage operation.  
NOTE:  
Outdoor fan motor will continue to operate for one  
The nominal requested airflow in high stage will be 350 cfm per ton  
of nominal cooling capacity as defined by unit size. Actual airflow  
request will be adjusted from nominal using indoor and outdoor  
temperature and indoor humidity data to optimize the system  
operation for occupant comfort and system efficiency. Refer to UI  
literature for further system control details.  
minute after compressor shuts off, when outdoor ambient is greater  
than or equal to 100°F (38°C).  
UTILITY INTERFACE WITH INFINITY CONTROL  
The utility curtailment relay should be connected to factory  
supplied pigtails (PINK connected to R, VIOLET connected to Y2  
on the control board) located in the low voltage splice box (see  
Typical Wiring Schematic ). This input allows a power utility  
device to interrupt compressor operation during peak load periods.  
When the utility sends a signal to shut the system down, the UI will  
display “Curtailment Active”.  
Airflow during electric heater operation must be greater than a  
minimum level for safe operation. If UI instructs unit to turn on  
electric heat and the requested airflow is less than the minimum level  
the fan coil control will override requested value.  
NOTE: Once the compressor has started and then has stopped, it  
should not be started again until 4 minutes have elapsed. The cooling  
cycle remains “on” until the room temperature drops to point that is  
slightly below the cooling control setting of the UI.  
Infinity Controlled Low Ambient Cooling  
NOTE: When this unit is operating below 55_F (12.7°C) outdoor  
temperature, provisions must be made for low ambient operation.  
This unit is capable of low ambient cooling down to 0_F  
(--17.7°C)ONLY when using the Infinity control. A low ambient kit  
isnotrequired,andtheoutdoorfanmotor doesnot needto bereplaced  
for Infinity controlled low ambient operation. Low ambient cooling  
must be enabled in the UI set--up. Fan may not begin to cycle until  
about 40_F (4.4°C) OAT. Fan will cycle based on coil and outdoor  
air temperature.  
COOLING AND HEATING OPERATION  
With a call for first stage cooling, the outdoor fan, reversing valve,  
and low stage compressor are energized. If low--stage cannot  
satisfy cooling demand, high--stage cooling is energized by the UI.  
After second stage is satisfied, the unit returns to low--stage  
operation until first stage is satisfied or until second stage is  
required again. When both first stage and second stage cooling are  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Fan wheel shall be made from steel, be double--inlet type. It  
shall have forward--curved blades with a corrosion--resistant  
finish and shall be dynamically balanced.  
GUIDE SPECIFICATIONS  
SINGLE--PACKAGED HEAT PUMP UNITS  
CONSTANT VOLUME APPLICATION  
3. Outdoor fan shall be of the direct--driven propeller type with  
aluminum blades, riveted to corrosion--resistant steel spiders.  
It shall be dynamically balanced, and discharge air vertically.  
HVAC GUIDE SPECIFICATIONS  
SIZE RANGE: 2 TO 5 TONS, NOMINAL (COOLING)  
MODEL NUMBER: 50XT  
D. Compressor:  
1. Fully hermetic, 2--stage scroll compressors with  
factory--installed vibration isolation.  
PART I -- GENERAL  
SYSTEM DESCRIPTION  
2. Scroll compressors shall be standard on all units.  
3. Compressor Protection:  
Outdoor rooftop or ground mounted heat pump unit utilizing a  
hermetic, 2--stage scroll compressor for heating and cooling duty  
and optional electric heating. Unit shall discharge supply air ver-  
tically or horizontally as shown on contract drawings. Outdoor  
fan/coil section shall have a draw--thru design with vertical dis-  
charge for minimum sound levels.  
Defrost control shall protect compressor by preventing  
“short cycling.”  
E. Coils:  
1. Indoor and outdoor coils shall have aluminum plate fins  
mechanically bonded to seamless copper tubes with all joints  
brazed.  
QUALITY ASSURANCE  
A. Unit shall be rated in accordance with ARI Standards  
210/240 and 270.  
2. Tube sheet openings shall be bellied to prevent tube wear.  
B. Unit shall be designed in accordance with UL Standard  
1995.  
C. Unit shall be manufactured in a facility registered to ISO  
9001 manufacturing quality standard  
F. Refrigerant Metering Device:  
Refrigerant metering device shall be of the single body,  
fixed orifice feed type (outdoor) and TXV (indoor).  
G. Filters:  
Filter section shall consist of field--installed, throw--away,  
1--in. thick fiberglass filters of commercially available sizes.  
D. Unit shall be UL listed and c--UL certified as a total  
package for safety requirements.  
H. Controls and Safeties:  
E. Roof curb shall be designed to conform to NRCA  
Standards.  
F. Insulation and adhesives shall meet NFPA 90A  
requirements for flame spread and smoke generation.  
1. Unit controls shall be complete with self--contained low  
voltage control circuit.  
2. Units shall incorporate an internal compressor protector that  
provides reset capability.  
G. Cabinet insulation shall meet ASHRAE Standard 62P.  
DELIVERY, STORAGE, AND HANDLING  
3. Unit shall provide high-- and low--/loss--of--charge pressure  
safety protection.  
Unit shall be stored and handled per manufacturer’s recommen-  
dations.  
I. Operating Characteristics:  
1. Unit shall be capable of starting and running at 125°F  
(51.6_C) ambient outdoor temperature, exceeding maximum  
load criteria of ARI Standard 240.  
PART 2-- PRODUCTS  
EQUIPMENT  
A. General:  
2. Compressor shall be capable of operation down to 55°F  
(12.7_C) ambient outdoor temperature in cooling and --10°F  
in heating.  
Factory--assembled, single--piece, heat pump. Contained within  
the unit enclosure shall be all factory wiring, piping, controls, re-  
frigerant charge (R--410A), and special features required prior to  
field start--up.  
3. Unit shall be capable of low--ambient cooling (below 55_F  
(12.7_C) ambient outdoor temperature) with low--ambient  
cooling enabled on the UI.  
B. Unit Cabinet:  
1. Unit cabinet shall be constructed of phosphated, zinc--coated,  
prepainted steel capable of withstanding 500 hrs of salt spray.  
J. Electrical Requirements:  
All unit power wiring shall enter unit cabinet at a single location.  
2. Normal service shall be through a single removable cabinet  
panel.  
K. Motors:  
1. Compressor motors shall be of the refrigerant--cooled type  
with line--break thermal and current overload protection.  
3. The unit shall be constructed on a rust proof unit base that has  
an externally trapped, integrated sloped drain pan.  
2. All fan motors shall have permanently lubricated bearingsand  
inherent automatic--reset thermal overload protection.  
4. Indoor fan compartment top surface shall be insulated with a  
minimum 1/2--in. (13 mm) thick, flexible fiberglass  
insulation, coated on the air side and retained by adhesive and  
mechanical means. The indoor wall sections will be insulated  
with a foil--faced insulation capable of being wiped clean.  
Aluminum foil--faced fiberglass insulation shall be used in the  
entire indoor air cavity section.  
3. Outdoor fan motor shall be totally enclosed.  
L. Grille  
1. Louvered Grille:  
Louvered grille shall be standard on all units.  
5. Unit shall have a field--supplied condensate trap.  
C. Fans:  
1. The indoor fan shall be variable--speed motor and control, as  
shown on equipment drawings.  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Filter Rack Kit:  
GUIDE SPECIFICATIONS (CONT)  
Shall provide filter mounting for downflow and horizontal  
applications.  
M. Special Features:  
1. Coil Options:  
7. Square--To--Round Duct Transitions:  
Shall include factory--installed optional tin--plated indoor  
copper/copper and vinyl--coated refrigerant coils.  
Shall have the ability to convert the supply and return open-  
ings from rectangular to round (024--048 sizes only).  
2. Flat Roof Curb:  
8. Crankcase Heater:  
Curbs shall have seal strip and a wood nailer for flashing and  
shall be installed per manufacturer’s instructions.  
Shall provide anti--floodback protection for low--load cool-  
ing applications. (Standard on 042--060 sizes.)  
3. Manual Outdoor Air Damper:  
9. Electric heaters:  
Package shall consist of damper, bird screen, and rain hood  
which can be preset to admit outdoor air for year--round ven-  
tilation.  
a. Electric heater shall be available as a field--installed  
option.  
b. Heater elements shall be open--wire type, adequately  
supported and insulated with ceramic bushings.  
c. Electric heater packages must provide single--point  
power connection capability.  
4. Infinityt User Interface:  
Toprovidefortwo--stage heatpump heating, two--stagecool-  
ing, and electric (auxiliary) heat, in addition to manual or au-  
tomatic changeover and indoor fan control.  
10. Compressor Hard Start Kit:  
5. Low--Ambient Cooling:  
Shall be available to give a boost to the compressor motor at  
each start--up.  
Low--ambient cooling must be enabled in the UI setup to al-  
low unit to operate down to 0°F (--17_C) outdoor ambient  
temperature in cooling.  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Catalog No: 50XT---04PD  
Copyright 2008 Carrier Corp. D 7310 W. Morris St. D Indianapolis, IN 46231  
Printed in U.S.A.  
Edition Date: 06/08  
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.  
Replaces: 50XT---3PD  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Blackberry Baby Gym 9780 User Manual
Blanco Indoor Furnishings 501 119 12 User Manual
Brother Sewing Machine INOV 40 User Manual
Bush Hog Saw 00786976C User Manual
Casablanca Fan Company Outdoor Ceiling Fan C31UxxB User Manual
Casio Cash Register PCRT48S User Manual
Casio Electronic Keyboard PX735 ES 1A User Manual
Cecilware Griddle EL 1624T User Manual
Cerwin Vega Car Amplifier CV 1800 User Manual
Cisco Systems Modem DPQ2202 User Manual