Deleting and Correcting an Expression
In insert mode: Move the cursor to the right of the character
To select the statistical display format [3] STAT
([1] ON or [2] OFF)
[1] ON: Show FREQ (Frequency) Column in Statistical
Data Input Screen
[2] OFF: Hide FREQ (Frequency) Column in Statistical
Data Input Screen
To select the angle unit [3] Deg, [4] Rad or [5] Gra
[3] Deg: Angle unit in Degree
[4] Rad: Angle unit in Radian
Omit the multiplication sign and final close parenthesis.
How to use the Slide Cover
Open or close the cover by sliding as shown in the figure.
LCD
Operation
Mode
CONTENTS
GETTING STARTED
Power ON, OFF
INPUTTING EXPRESSIONS AND VALUES
Input Capacity
ENGLISH
Indicator
Example: 2 x log 100 x (1+3) = 16
or function that needs to be deleted, then press
.
DISPLAY (4-line Dot Matrix DISPLAY)........................................P. 3
GETTING STARTED......................................................................P. 4
Power ON, OFF ........................................................................P. 4
Display Contrast Adjustment.....................................................P. 4
Mode Selection .........................................................................P. 4
Calculator Set-up Menu ............................................................P. 5
Before Using the Calculator......................................................P. 7
INPUTTING EXPRESSIONS AND VALUES.................................P. 8
Input Capacity...........................................................................P. 8
Input Editing..............................................................................P. 8
Inputting and Display result in Maths Mode............................P. 11
INPUT RANGE AND ERROR MESSAGE...................................P. 11
Calculation Precision, Input Range.........................................P. 11
Order of Operations ................................................................P. 14
Calculation Stacks ..................................................................P. 16
Error Message and Error Locator ...........................................P. 16
BASIC CALCULATIONS.............................................................P. 17
Arithmetic Calculations ...........................................................P. 17
Memory Calculations ..............................................................P. 17
Fraction Calculations ..............................................................P. 19
Percentage Calculations.........................................................P. 20
Degree-Minutes-Seconds Calculations...................................P. 20
Reply & Multi-statements........................................................P. 21
FUNCTIONAL SCIENTIFIC CALCULATIONS............................P. 22
Square, Root, Cube, Cube Root, Power Root,
COMP Normal calculation
[5] Gra: Angle unit in Gradient
Operation 1:
Display 1
First time operation:
1. Pull out the battery insulation sheet, then the battery will
be loaded.
F-718S allows you to input a single calculation up to 99
bytes. Normally, one byte is used as each time you press
one of the numeric keys, arithmetic keys, scientific function
STAT
Statistical calculation
STAT
In overwrite mode: Move the cursor under the character or
function being deleted, then press
Including
*2,
*1,
*3
2xlog(100) x (1+3)
.
90º = radians = 100grads
TABLE Function Table calculation
*2
*1
2. Press
to reset the calculator.
keys or
,
. Some functions require 4 – 13bytes.
, and the direction keys will not use up any bytes.
Example: 1234567 + 889900
To select the decimal point display format [4] Disp
([1] Dot or [2] Comma)
[1] Dot: specify dot format for Decimal point result display
[2] Comma: specify comma format for Decimal point
result display
To select display digit or notation [6] Fix, [7] Sci or
[8] Norm
[6] Fix: Fixed Decimal, [Fix 0~9?] appears, specify the
number of decimal places by pressing [0] – [9].
Example: 220 ÷ 7 = 31.4286 (FIX 4)
= 31.43 (FIX 2)
Initial mode is COMP mode.
16
*3
Power ON: When
Power OFF:
is pressed.
When input capacity is less than 10bytes, the input cursor
will change from “ ” to “ ” that notifying the memory is
running now.
(1) Replace an entry (1234567 1234560)
OPEN
CLOSE
Operation 2:
Display 2
Calculator Set-up Menu
2log(100)(1+3
Omitting
Omitting
*1,
*3
are pressed.
F-718S/F-718SGA/
F-718SG/F-718SA
DISPLAY (4-line Dot Matrix DISPLAY)
Press
press
to enter the Calculator Set-up Menu;
for next / previous page.
/
Auto Power off Function:
When the calculator is not used for about 7 minutes, it
will automatically power off.
16
To Adjust Display contrast [5]
See “Display Contrast Adjustment” section.
CONT
Input Editing
[7] Sci: Scientific Notation, [Sci 0~9?] appears, specify
the number of significant digits by pressing [0] – [9].
Example: 220 ÷ 7 = 3.1429 x 101 (SCI 5)
= 3.143 x 101 (SCI 4)
New Input begins on the left of display. If input data are
more than 15 characters, the line will scroll to the right
consecutively. You can scroll back to the left by using
*1. Omit multiplication sign (x)
- Input before an open parentheses
: 1 x (2+3)
Before Using the Calculator
Press
or
Display Contrast Adjustment
key
- Input before scientific functions that includes
parenthesis: 2 x cos(30)
- Input before Random number function
Check the current Calculation Mode
Press
Display Contrast Adjustment screen.
(5:
CONT
), enter the
and
to review the input
Be sure to check the status indicators that indicate the
current calculation mode (COMP, STAT, TABLE), display
formats setting and angle unit setting (Deg, Rad, Gra)
[8] Norm: Exponential Notation, [Norm 1~2?] appears,
specify the exponential notation format by pressing [1] or
[2].
To select the calculator input & output format [1]
Maths or [2] Line
[1] Maths – (Maths mode): The majority of calculation
input and output (e.g. Fraction, pi, square root
number) are shown in Mathematics textbook format.
In Line mode, press to let the cursor jump to the
beginning of inputting, while will jump to the end.
- Input before Variable (A, B, C, D, X, Y, M), π, е
*2. Scientific functions come with the open parenthesis.
Example: sin(, cos(, Pol(, LCM(…. You need to input the
<Status Indicators>
S
: Shift key
Return to initial setup
Reciprocal and pi ....................................................................P. 22
Logarithm, Natural Logarithm, Antilogarithm and logab..........P. 22
Angle Unit Conversion ............................................................P. 22
Trigonometry Calculations ......................................................P. 23
Permutation, Combination, Factorials and Random
A
: Alpha key
In Maths mode, press
beginning of inputting while it is at the end of the input
calculation. Or press to let the cursor jump to the end
to let the cursor jump to the
argument and the close parenthesis
.
*3. Omit the last close parenthesis before the
Norm 1: Exponential notation is automatically used for
integer values with more than 10 digits and decimal
values with more than TWO decimal points.
Pressing
(YES)
: COMP
: Maths
: Deg
to return the
,
,
M
: Independent memory
: Store memory
: Recall memory
: Statistics mode
: Degree Mode
initial calculator setup
Calculation mode
Input/Output Format
Angle unit
(2) Deletion (1234567 134567)
Press
Press
Press
to make the display contrast darken.
to make the display contrast lighten.
or to confirm and clear the screen.
,
.
STO
RCL
STAT
D
[2] Line – (Line mode): The majority
of calculation input and output are
shown in the lines format. And
“LINE” icon will be shown.
Maths mode
of inputting while it is at the beginning of the input
calculation.
Number Generation ................................................................P. 24
Least Common Multiple and Greatest Common Divisor.........P. 25
Quotient and Remainder Calculations ....................................P. 26
Coordinate Conversion ...........................................................P. 26
Absolute Value Calculations ...................................................P. 27
Engineering Notation ..............................................................P. 27
Display Values Exchange .......................................................P. 28
STATISTICAL CALCULATIONS.................................................P. 29
Statistical Type Setection........................................................P. 29
Statistical Data Input...............................................................P. 29
Editing Statistical Sample Data...............................................P. 30
Statistical Calculation Screen .................................................P. 31
Statistical Menu.......................................................................P. 31
Statistical Calculation Example...............................................P. 33
FUNCTION (x, y) TABLE CALCULATION..................................P. 34
BATTERY REPLACEMENT ........................................................P. 36
ADVICE AND PRECAUTIONS....................................................P. 37
SPECIFICATIONS .......................................................................P. 38
Method 1: Line/Maths
mode - Insert mode
Method 2: Line mode -
Overwrite mode
12times
12|34567+889900
134567+889900
1234567+889900_
1234567+889900
134567+889900
Insert and overwrite Input mode
In Line mode, you can use INSERT
for inputting.
Norm 2: Exponential notation is automatically used for
integer values with more than 10 digits and decimal
values with more than NINE decimal places.
or overwrite mode
Display Digits
: Norm 1
: d/c
: OFF
: Dot
To initialize the LCD contrast, press
outside the Display Contrast Adjustment screen.
Fraction Display Format
Statistical Data Input
Decimal Point format
- In Insert mode (Default input mode), the cursor is a
vertical flashing line “ | ” for inserting a new character.
R
: Radian Mode
Line mode
For the STAT mode, the Input &
Display format will switch to Line
mode automatically.
NOTES
13times
Example: 1 ÷ 1000 = 1 x 10-3 (Norm 1)
= 0.001 (Norm 2)
LINE
G
: Gradient Mode
: Fixed-decimal setting.
: Scientific Notation
: Line Display mode
: Up Arrow
F-718SGA and F-718SG the top case, bottom case,
battery cover and hard case in this product are made
from recycled Canon copier plastic.
Mode Selection
- In overwrite mode, press
key to switch the
This action will not clear the variable memories.
FIX
SCI
LINE
cursor to a flashing horizontal ( _ ) and replace the
character at the current cursor position.
Press
screen.
Press
to enter the Calculation Mode Selection
To select the fraction format [1] a b/c or [2] d/c
[1] a b/c: specify Mixed fraction display
[2] d/c: specify Improper fraction display
Initialize the calculator
(3) Insertion (889900 2889900)
,
,
to select the calculation mode.
When you are not sure of the current calculator setting, you
are recommended to initialize the calculator (calculation
mode “COMP”, angle unit “Degree”, and clear reply and
variable memories), and LCD contrast by pressing
In Maths mode, you can only use the insert mode.
Line/Maths mode -
Insert mode
6times
1234567+|889900
1234567+2|889900
: Down Arrow
Whenever the display format changes from Line mode to
Maths mode, it will automatically switch to the insert mode.
Disp
: Multi-statements Display
(All)
(YES)
.
E-IE-410
PRINTED IN CHINA
2
3
4
5
6
7
8
9
10
Function Calculation Input Ranges
Fraction Calculations
Percentage Calculations
Example in
Inputting and Display result in Maths Mode
5th
Fractions: a b/c, d/c
Calculation Stacks
Functions
Input Range
|x|,|y| 9.999 999 999x1099
x2+y2 9.999 999 999x1099
Functions
Abs
Input Range
BASIC CALCULATIONS
Functions
Input Range
|x| <9×109
|x|<1x10100
|x|<1x10100
6th
7th
8th
Prefix symbol: (–) (negative sign)
The calculator supports Fraction calculation and the
conversions between Fraction, Decimal point, Mixed fraction
and Improper fraction.
Example in
In Maths Mode, the Input and display result of fraction or
, x-1, 10 , e ,
This calculator uses memory areas, called “stacks”, to
temporarily store numeric value (numbers) and commands
(+, –, x…) according to their precedence during calculations.
The numeric stack has 10 levels and command stack has
128 levels. A stack error [Stack ERROR] occurs whenever
you try to perform a calculation that exceeds the capacity of
stacks.
Calculations are performed in sequence according to “Order
of Operations”. After the calculation is performed, the stored
stack values will be released.
Key in operation
Display
Press
to enter COMP mode.
Pol(x,y)
3
certain functions (log, x2, x3, x ,
Abs) is shown in Handwriting/Mathematics format.
,
,
One-variable
Statistical
calculation
Maths mode
Statistical estimated value calculation: x, y, x1, x2
DEG
RAD
GRA
DEG
RAD
GRA
DEG
RAD
GRA
0
0
0
0
0
0
ˆ ˆ ˆ
ˆ
During the busy calculation, the calculator shows only
the indicators (without any calculation result). You can
23 + 7
A
23+7
A
sinx
|x| <157 079 632.7
|x| <1x1010
0
r
9.999 999 999x1099
: Same as sinx
|a|,b,c <1x10100
b,c
|FREQ|<1x10100
|x|<1x10100
Multiplication where sign is omitted: Multiplication sign
omitted immediately before , e, variables (2 , 5A, A,
etc.), functions with parentheses (2 (3), Asin(30), etc.)
Permutations, combinations: nPr, nCr
Key in operation
Display
•
Specify the fraction calculation result display format by either
mixed fraction (a b/c) or improper fraction (d/c) in set-up
menu.
Maths mode
To calculate 25% of
820 (Maths mode)
Rec(r, )
30
1
Two-variable
Statistical
press
key to interrupt the calculating operation.
820x25%
2 x sin A = 1
2sin(A
|x| <9×109
|y|<1x10100
205
•
•
At the default setting, fractions are displayed as improper
fractions (d/c).
Mixed Fraction display result only available after set the (a
b/c) in the setup menu.
100
|FREQ|
Example in
Arithmetic Calculations
9th
calculation
cosx
tanx
|x| <157 079 632.7
|x| <1x1010
0
<1x10
Key in operation
Display
The percentage of
750 against 1250
(Maths mode)
750÷1250%
Maths mode
Clear memory
0
A
°′ ″
10th
11th
12th
Multiplication and division: ×, ÷
•
To calculate with negative values (exclude the negative
exponent) enclose then with parentheses.
This calculator supports 99 levels of parenthetical
expression.
The display seconds value is subject to an error of
+/-1 at the second decimal place
|x|<1x10100
•
Errors are cumulative in the case of consecutive
calculations, this is also true as internal consecutive
calculation are performed in the case of ^(xy), x√y, 3√, x!,
nPr, nCr , etc. And may become large.
0
Addition and subtraction: +, –
Same as sinx, except when |x| =(2n-1)×90
Same as sinx, except when |x| =(2n-1)× /2
Same as sinx, except when |x| =(2n-1)×100
60
Improper Fraction
(d/c)
11
Mixed Fraction
(a b/c)
•
Calculation ending instruction: =, M+,M- STO(store
memory),FMLA
Independent Memory
Independent memory
as variable M. It is convenient for calculating cumulative
total by just pressing
(subtract from memory)
Memory contents are retained even when the calculator
is powered off.
Clear independent memory (M) by pressing
Error Messages and Error locator
Deciaml
Sexagesimal Conversions
•
uses the same memory area
2
Maths Mode
3
The calculator is locked up while an error message is shown on
the display to indicate the cause of the error.
° ″
sin-1x
cos-1x
tan-1x
sinhx
coshx
sinh-1x
cosh-1x
tanhx
tanh-1x
logx/lnx
10x
0°0′0″ |x| 9999999°59′59″
x>0: -1x10100 < ylog x < 100
Display of results using
Calculation results may be displayed using
the following cases:-
1. When intermediate and final calculation results are
displayed in the following form:
3
3
Remark
In the same precedence level, calculations are
performed from left to right.
Operation enclosed within parentheses is performed
first. When a calculation contains an argument that is a
negative number, the negative number must be enclosed
within parentheses.
0
0
0
|x|
1
Degree-Minutes-Seconds Calculations
(add to memory) or
when all of
(1) Some input expressions cause the height of a
calculation expression to be greater than one display
screen. Maximum input capacity: 2 display screen
(31 dots x 2).
(2) Calculator memory limits how many functions or
perentheses can be input in any single expression. In
this case divide the expression into multiple parts and
calculate separately.
Example in
Press
initial display of latest mode.
Press or to display input expression with the cursor
positioned next to the error.
to clear the error message, then return to the
Key in operation
Display
11_|3
3_|2_|3
Line Mode
Press
Maths mode
Use degrees (hours), minutes and seconds key to perform a
sexagesimal (base-60 notational system) calculation or convert
the sexagesimal value into decimal value.
|x| 9.999 999 999x1099
x=0: y>0
•
•
•
^(xy)
(-2.5)2
(-2.5)2
to switch a calculation result between fraction and
25
4
x<0: y=n,m/(2n+1) (m,n are integers)
However: -1x10100<ylog|x|<100
y>0: x 0, –1x10100<1/x logy<100
y=0:x>0
|x| 230 258 509 2
decimal format.
Press
improper fraction and mixed fraction format.
Press
to clear the error message, clear the replay
to switch a calculation result between
|x| 4.999 999 999x1099
memory history and return to the initial display of the latest
mode.
(4 x 1075)(-2 x
4E75x-2E-79
Degree-Minutes-seconds
Decimal points
0
1
0
0
Clear all memory values by pressing
2(MCL)
10-79
)
Result will be displayed in decimal format automatically
whenever the total digit of a fractional value (integer +
numerator + denominator + separator marks) exceeds 10.
As a fraction calculation is mixed with decimal value, the
result will be displayed by decimal format.
x
4.999 999 999x1099
x
Example:
1
√y
|x| 9.999 999 999x1099
|x| 9.999 999 999x10-1
y<0:x=2n+1,(2n+1)/m (m≠0;m,n are integers)
However: -1x10100<(1/x)log|y|<100
Total of integer, numerator, and denominator must be
10 digits or less (including division marks).
Error Message
Math ERROR
Cause
Action
–22 = –4
(–2)2 = 4
1250
Example in
2. When the number of terms in the intermediate and final
calculation result is one or two.
(3) If part of the expression you input is cut off after
calculation and in the result display screen you can
Key in operation
Display
• The intermediate or final
result is outside the
allowable calculation
range.
Check the input values
and make sure they are
all within the allowable
ranges, Pay special
Answer Memory
The input values or the most recent calculation result will
be automatically stored into Answer memory whenever
you press
memory can hold up to 18 digits.
Recall and use the latest stored Answer memory by
pressing
Answer memory is not updated as an error operation
had been performed.
Answer memory contents can be maintained even if
Maths mode
86º37’34.2” ÷ 0.7 =
•
0< x 9.999 999 999x1099
86º37 º 34.2 º ÷ 0.7
press
or
to view the full expression.
a b/c
Memory Calculations
Memory Variables
There are 17 memory variables (0 – 9, A – D, M, X and
Y), which store data, results, or dedicated values.
Store values into memory by pressing
variable.
Recall memory values by pressing
variable.
Memory content can be cleared by pressing
123º45’6” (Maths mode)
-9.999 999 999 x1099
-9.999 999 999 x1099
x
x
99.999 999 99
230.258 509 2
Fraction
Decimal point conversion
Key in operation
Order of Operations
When same priority commands are mixed into one
calculation.
• An attempt to perform a
attention to values in any
,
,
,
,
. Answer
ex
0
a<1x1010, 0 b<1x1010 (a,b should be positive
calculation using a value using memory areas
that exceeds the
allowable input range.
• An attempt to perform an
illogical operation
(division by zero, etc.)
This calculator will automatically determine the operation
priority of each individual command as follows:-
123º45’6”
i~Rand(a,b)
Rand
•
•
•
•
x <1x10100
integers or 0)
•
•
•
√x
0
INPUT RANGE AND ERROR MESSAGE
123º45’6” 123.7516667
86º37 º 34.2 º ÷ 0.7
123.7516667
Example in
Maths mode
.
Example 1:
x2
|x|<1x1050
Result generates a 3 digits pseudo random
Display
+ Memory
(Maths mode)
1st Priority Recall memory (A, B, C, D, 0-9), Rand
1 ÷ 2 = 0.1591549431
x3
|x| 2.154 434 69x1033
number(0.000~0.999)
Calculation Precision, Input Range
1
2
5
6
7
3
1
1
5
6
2.3456 2º20’44.16”
2.3456
1
+
=
+
2nd
3rd
Calculation within parentheses ( ).
x-1
|x|<1x100100,x
|x|<1x10100
0
0<x, y, z 9.999 999 999x1012 (positive integers)
Default result when x, y, z=0
2
Stack ERROR • The capacity of the
numeric stack or
operator stack is
• Simplify the calculation.
• Divide the calculation
into two or more
+ Memory
(Maths mode)
2º20’44.16”
Example 2:
LCM(x,y,z)
GCD(x,y,z)
Function with parenthesis that request the input
argument to the right Pol(, Rec( , sin(, cos(, tan(,
sin–1(, cos–1(, tan–1(, sinh(, cosh(, tanh(, sinh–1(,
cosh–1(, tanh–1(, log(, ln(, e^(, 10^(, (, 3 (, Abs(,
ROUND(, LCM(, GCD(, Q…r(, i~Rand(,
7
3
Number of Digits for
Internal Calculation
Up to 18 digits
3√x
pressing
off the calculator.
, changing the calculation mode, or turning
in Maths mode
2
A
1
4
exceeded.
separate parts.
x!
0
0
1
0
1
x
69 (x is an integer)
0<x, y, z 9.999 999 999x1012 (positive integers)
1
1
5
6
7
Precision*
±1 at the 10th digit for a single calculation.
±1 at the least significant for exponential
display
+ Memory variable.
1 ÷ 2A =
2.333333333
+
+
Syntax ERROR An attempt to perform an
illegal mathematical
operation.
Press
or
to display
Example in
n < 1x1010, 0
r
n (n,r are integers)
Default result when x, y, z=0
2
Key in operation
Display
3
(Fraction
the cursor at the location
of the error, make
appropriate corrections
Maths mode
nPr
nCr
{n!/((n-r)!) < 1x10100
n < 1x1010, 0
n (n,r are integers)
0<x,y 9.999 999 999x1012 (positive integers)
Decimal)
2.333333333
Example: 23 + 7 A (30 store into A), calculate 2 sinA
and clear memory A.
123 + 456
M+,
Ans2
Calculation Range
±1 × 10–99 to ±9.999999999 × 1099 or 0
1
3
1
2
5
6
r
0
Q
999 999 9999, 0
r
999 999 9999 (Q,r are
2.333333333
2
Ans2 = 335,241
335241
1
4th
Functions that come after the input value preceded by
values, powers, power roots:
Q…r(x,y)
Insufficient
MEM
The calculation result of
Function Table mode
parameters caused more
than 30 x-values to be
generated for a table
Narrow the table
calculation range by
changing the start, end,
and step values, and try
again.
n!/r! < 1x10100 or 1 n!/(n-r)! < 1x10100
integers)
(Decimal
Fraction)
Mixed
1
3
2
789900 – Ans =
454,659
789900-Ans
454659
Default result when x=0
x2, x3, x–1, x!, ° ’ ”, °, r, g, ^(, x (, Percent %, logab, EXP
Download from Www.Somanuals.com. All Manuals Search And Download.
15 16
11
12
13
14
17
18
19
20
•
•
After turned on Data Frequency “FREQ” in calculator’s setup
menu, the FREQ column will be added into the above screen.
The followings are the maximum number of line for data input.
Press the corresponding number key
angle unit you need. Then the display will show the
Indicator accordingly.
,
or
for the
,
Random Number Generation
Hyperbolic (sinh/ cosh/ tanh), Inverse Hyperbolic
(sinh-1/cosh-1/tanh-1) functions
: Convert rectangular coordinates (x, y) to polar
for r, or
Replay & Multi-statements
Quotient and Remainder Calculations
Display Values Exchange
FUNCTIONAL SCIENTIFIC CALCULATIONS
STATISTICAL CALCULATIONS
Press to enter Statistical calculation mode and
“STAT” indicator lights up.
,
D
R
G
coordinates (r, θ); Press
for θ.
: Generate a random number between 0.000 and
0.999. And the display result will be fraction format
in Maths mode status.
Replay Memory Function
“Quotient” (Q) is the result of a division problem, “Remainder”
(r) is the value remaining in an integer division problem.
The calculated quotient value (Q) and remainder (r) will be
stored into memory variables “C” and “D” automatically
assigned.
In Maths mode, pressing
result value between fraction form Decimal form, form
Decimal form, √ form Decimal form.
to change the calculation
Pressing
enter sub-hyperbolic menu.
Press
to enter COMP mode.
• Replay memory is only available in COMP mode.
• After the calculation is executed, the calculation input and
result will be stored in the replay memory automatically.
Convert an angle unit between “Degree”, “Radian” and
“Gradient” by pressing
= 3.1415926535897932324
Example in
Key in operation
Display
Statistic type
FREQ ON
FREQ OFF
Maths mode
e = 2.7182818284590452324
Press
(Type) to select the calculation type.
In Line mode, pressing
result value between fraction form Decimal form, the other
and √ calculation will display the decimal value only.
to ONLY change the calculation
Single Variable (only x input)
2 Variable (x & y input)
40
26
80
40
Pol(1, √3
With rectangular
coordinate (x=1, y=
√3). Find Polar
: Generate a random number between two specified
positive integers. The entry is divided by “.”
• Pressing
input and result history.
(or
) can replay the performed calculation
Square, Root, Cube, Cube Root, Power, Power Root,
Reciprocal and Pi
In Maths mode, press
result.
or
to scroll a long calculation
Statistical Type Selection
r=2, þ=60
• After obtaining the calculation result on the display,
coordinate (r, θ) at
degree mode
There are 8 types of Statistical Calculation, after entered the
Statistical Type Selection screen, then press the number to
select the type of Statistic Calculation.
X
Y
In Line mode, the quotient value (Q) and remainder (r) will be
shown over 2 line.
Only Quotient Value (Q) can continue to be used for the next
calculation or be stored into memory variables.
•
•
Input expression and display result value in Statistical Data
Input screen are in Line mode (same as Comp mode with
Line mode status).
press
• If the Indicator is on the right side of a calculation result
or
to edit the input expression of that result.
2
Example in
Example in
Example in
Key in operation
Display
Then, pressing
value into the selected angle unit.
,
, or
will convert the displayed
Example in
display, you need to press
the calculation.
• Replay memory is cleared when you press
1. Initialize calculator setting by
2. Change from one calculation mode or display mode to
other.
and then
or
to scroll
Key in operation
Display
Key in operation
Display
Line mode
Key in operation
Display
Maths mode
Maths mode
60
Maths mode
After inputted the data, then press
to store the value into
2_|3+2
Generate a random
number between
0.000 & 0.999
Rand
sinh2.5 – cosh 2.5
= -0.08208499862
statistical registers and display the value (max. 6 digits) in the
cell. And you can press cursor key to move the cursor
between each cell.
: Convert polar coordinates (r, θ) to rectangular
8_|3
(In Line Mode)
139
1000
coordinates (x, y); Press
for y.
for x, or
Example in
Example in Line
Key in operation
Display
sinh(2.5) – cosh(
-0.08208499862
Key in operation
Display
2_|3+2
Maths mode
Convert 180
mode
35 ÷ 10 = 3 x 10 +5
= 0.6217559776
0.6217559776
2.666666667
R
Q…r(35, 10
Q=
R=
180º
180º
Example in
Generate an integer
from range of 1 to
100
i~Rand(1,100
Key in operation
Display
3. Press
4. Press
key.
Q=3
R=5
3
Cosh-145
cosh-1(45
degree into radian
and gradient
Line mode
Editing Statistical Sample Data
Pressing Key
1 (SD)
Statistical Calculation
One-variable statistics (x)
33
5
to power off machine.
Rec(2, 60
X=
Y=
With Polar coordinate
(r=2, θ=60º).
Find Rectangular
coordinate (x, y) at
degree mode
Rad
= 4.499686191
4.499686191
(Line mode)
Replacing the Data in a cell
(1) In Statistical Data Input screen, move the cursor to cell
you want to edit.
(2) Input the new data value or expression, and then press
(180º =
200Gad
=
1
1.732050808
Example in
Key in operation
Display
)
2 (Lin)
Two-variable, Linear regression (y= A+Bx)
Two-variable, Quadratic regression (y=A +Bx + Cx2)
*The value is only a sample, results will differ each time.
Quotient value (Q) + 3
= 6
Ans+3
Maths mode
Multi-statements Function
200
6
3
5
= 7
7
3 (Quad)
4 (Log)
• Use a colon
together.
to put two or more calculation input
1
2
X
+2
+2
Permutation, Combination, Factorials and Random
Number Generation
1
8
3
Least Common Multiple and Greatest Common Divisor
Two-variable, Logarithmic regression (y=AxBlnx)
Two-variable, E exponential regression (y=AeBx
)
Two-variable, ab Exponential regression (y=ABx)
Two-variable, Power regression (y=AxB)
Recall Quotient
value (Q)
C
D
Trigonometry Calculations
Before using the trigonometric functions (except
hyperbolic calculations), select the appropriate angle unit
(In Maths Mode)
• The first executed statement will have “Disp” indicator; and
the “Disp” icon will disappeared after the last statement is
being executed.
Y
Logarithm, Natural logarithm, Antilogarithm and logab
5 (e EXP)
6 (ab EXP)
7 (Pwr)
LCM: Calculate the least common multiple among
(maximum) three positive integers.
GCD: Calculate the greatest common divisor among
(maximum) three positive integers.
2
3
1.732050808
Deleting a line
(1) In Statistical Data Input screen, move the cursor to line
you want to delete.
(2) Press
Recall Remainder
value (r)
Permutation:
Combination:
Factorial:
2.666666667
Absolute Value Calculation
Example in
Example in
(Deg/Rad/Gra) by pressing
.
Key in operation
Display
8 (Inv)
Two-variable, Inverse regression (Y=A+B/x)
Maths mode
Coordinate Conversion
Angle Unit
Setting
Input Value Range
for form result
e-3 + 101.2 + In3 =
Key in operation
Display
Angle Value Input
Maths mode
Inserting a line
(1) In Statistical Data Input screen, move the cursor to the
With polar coordinates, you can calculate and Display θ
within –180º < θ ≤ 180º range. (Same as Radian and
Gradient)
Example in
Example in
Key in operation
Display
16.99733128
Key in operation
Display
Maths mode
Maths mode
Statistical Data Input
Deg
Rad
Gra
Units of 15º
Multiples of
Multiples of
Example
Key in operation
Display
line that will be under the line being inserted.
(Edit)
(Line)
1x12=12
2+25=27
using a multi-statement
in Maths mode
=2.573442045
1
12
1x12:2+25|
After confirmed the calculation type of the above Statistical
In Maths mode, press
result.
or
to scroll the calculation
3
3
radians
(2) Press
(3) Press
LCM(15, 27, 39)
= 1755
LCM(15,27,39
Example in
16.99733128
4
Type Selection screen or by pressing
STAT mode, the following Statistical Data Input screen will be
shown.
(Data) in the
Key in operation
Display
2.573442045
Maths mode
=0.5773502692
50
3
grads
In Line mode, (x,y) or (r, θ) will be shown over 2 line.
After conversion, the results will automatically be assigned to
memory variables X and Y. Press
results.
Disp
log381 – log1 = 4
10P3 = 720
10P3
5C2
5!
Deleting All STAT Data Input
1755
1x12
2+25
1x12
Engineering Notation
Example in
0.5773502692
720
10
(1) Press
(2) Press
(Edit)
or
to show the
90º = Radians = 100 Gradients.
12
27
12
1
÷8 =
8
=0.3926990817
(Del-A)
5C2 = 10
5! = 120
Key in operation
Display
1
8
Example in
Line mode
Key in operation
Maths mode
Display
Angle Unit Conversion
-3
1÷200 = 5x10
(In Line Mode)
1÷200
D
Example
Key in operation
Display
The calculator angle unit setting is “Degree”. Pressing
enter the setup menu to change the unit to “Radian” or
“Gradient”,:
Degree Mode
1-variable STAT
2-variable STAT
-3
-6
-3
5x10
5000x10
5x10
120
0.3926990817
Replay the previous
calculation history 1 x
12 = 12
GCD(12, 24, 60)
= 12
GCD(12,24,60
sin(60
3
Sin 60 =
2
3
2
1÷200
1÷200
REMARK
sin(45)-1
•
Some Calculation results, pressing
the display value.
Some display result conversion may take a long time.
key will not convert
1
12
=Cosec 45º =
Sin45o
2
Rectangular Coordinates
(Rec)
Polar Coordinates (Pol)
•
21
22
23
24
25
26
27
28
29
30
Please use the regression to estimate the effectiveness
3. Input the start, end & step information
• Input the value, press
screens
• Input expression and display result value in following
screens are in Line mode status
• There are maximum of 30 x-values for generate function
table. The “Insufficient Error” will be showed if you input
the start, end, step value combination is more than 30
x-values.
Statistical calculation result in [4] S-SUM, [5] S-VAR, [6]
S-PTS, [7] Reg
Statistical Calculation Screen
Statistical Calculation Example
ADVICE AND PRECAUTIONS
SPECIFICATIONS
BATTERY REPLACEMENT
When the display characters are dim or show the follow
message on the screen, turn the calculator off and replace
the lithium battery immediately.
(estimate the value of y) if the advertisement expenses X=30,
and estimate the advertisement expenses level (estimate the
value of X1, X2) for effectiveness y = 50.
to confirm on the following
SD type Statistical calculation Example:
After inputting the STAT Data, press
Statistical Calculation screen.
Statistical Calculation screen are in Line mode for
input & output Display
Use Statistical Menu to calculate the Statistical result.
(S-SUM, S-VAR, S-PTS, Reg).
to enter
To calculate ∑x2, ∑x, n, x, x n, x n-1, minX, maxX of data: 75,
85, 90, 77, 79 in SD mode (Freq: OFF)
•
This calculator contains precision components such as
LSI chips and should not be used in place subject to
rapid variations in temperature, excessive humidity dirt
or dust, or exposed to direct sunlight.
The liquid crystal display panel is made of glass and
should not be subjected to excessive pressure.
When cleaning the device do not use a damp cloth or
volatile liquid such as paint thinner. Instead, use only a
soft, dry cloth.
Do not under any circumstances dismantle his device. If
you believe that the calculator is not functioning
properly, either bring or mail the device together with the
guarantee to service representative of Canon Business
office.
Never dispose the calculator improperly such as
burning; it can create risks of personal injury or harm.
You are suggested to dispose this product according to
your national law.
Power Supply
: Single Lithium battery (CR2032 x 1)
STAT
STAT Type
Value
Symbol
Operation
sub-menu
Power Consumption : DC 3.0V / 0.3mW
2
2
S-SUM
1 & 2 variable Summation of all x value
∑x
Battery Life
: Approximately 3 years
Key in operation
Display
Key in operation
Display
STAT
Summation of all x value
∑x
(Base on 1 hour operation per day)
: Approx. 7 minutes
2
2
Auto power off
2-variable Summation of all y value
STAT only Summation of all y value
Summation of xy pairs
∑y
•
•
LOW BATTERY
Usable Temperature : 0° ~ 40°C (32°F ~ 104°F)
Size: 171 (L) × 86 (W) × 18.75 (H) mm (with cover) /
6-47/64” × 3-25/64” × 47/64” (with cover) /
168 (L) × 80 (W) × 14.5 (H) mm (without cover) /
6-19/64” × 3-5/32” × 37/64” (without cover)
Weight: 128 g (4.33 oz) (with cover) /
∑y
Statistical Menu
∑xy
Please replace the lithium battery using the following
procedures,
(Quad)
Display screen
You should input:-
(SD)
3
3
In Statistical Data Input screen or Statistical Calculation
Summation of all x value
∑x
Start?
End?
Input the lower limit of X (Default =1).
1. Press
to power off the calculator.
screen, you can press
Menu screen.
to display the Statistical
2
2
Summation of all x y pairs
∑x y
•
2. Remove the screw that securely fixes the battery cover
in place.
3. Remove battery cover.
4. Remove the old battery with ball pen or similar sharp
object.
5. Load the new battery with positive “+” side facing up.
Input the upper limit of X (Default = 5).
4
4
Summation of all x pairs
∑x
95.59 g (2.23 oz) (without cover)
*Specifications are subject to change without notice.
*End value must be greater than the start value.
S-VAR
1 & 2
Number of data sample
n
Step?
Input the increment step (Default =1).
variable
STAT
Mean of the x values
x
Population standard deviation of x
Sample Standard Deviation of x
x
WEEE AND EU BATTERY
DIRECTIVE 2006/66/EC
n
∑x2
∑x
n
•
•
1-variable STAT
2-variable STAT
In Function Table Result screen, you cannot edit the
6. Replace the battery cover, screw, and press
to initialize the calculator.
,
x
n-1
33120
406
5
30y
content, and press
return to Function Input screen.
2-variable Mean of the y values
STAT only Population standard deviation of y
Sample standard Deviation of y
y
European Union (and EEA) only.
48.69615715
STAT items
Description
f (x) = x3 + 3x2 2x
y
n
These symbols indicate that this product is not to be disposed
of with your household waste, according to the WEEE Directive
(2002/96/EC), the Battery Directive (2006/66/EC) and/or your
national laws implementing those Directives.
This product should be handed over to a designated collection
point, e.g., on an authorized one-for-one basis when you buy a
new similar product or to an authorized collection site for
recycling waste electrical and electronic equipment (EEE) and
batteries and accumulators. Improper handling of this type of
waste could have a possible impact on the environment and
human health due to potentially hazardous substances that are
generally associated with EEE.
Your cooperation in the correct disposal of this product will
contribute to the effective usage of natural resources.
For more information about the recycling of this product, please
contact your local city office, waste authority, approved scheme
or your household waste disposal service or visit
Example:
the range
to generate the function table for
Caution: Risk of explosion if battery is replaced by an
incorrect type. Dispose of used battery according
to the instruction.
50x1
50x2
Do replace the battery once very two years even it is not
used frequently.
, incremented in steps of 1.
[1] Type
[2] Data
[3] Edit
To enter the statistical calculation type screen
To enter the statistical Data input screen
y
n-1
31.30538226
-167.1096731
S-PTS
1 & 2 variable Minimum value of X
minX
Key in operation
Display
Battery Caution!
Keep the Battery out of reach of children. If the battery is
swallowed, contact a doctor immediately.
Misuse of battery may cause leakage, explosion,
damages or personal injury.
Don’t recharge or disassemble the battery, it could
cause a short circuit.
x
STAT
Maximum value of X
maxX
Electromagnetic interference or electrostatic discharge
may cause the display to malfunction or the contents of
the memory to be lost or altered. Should this occur,
f(x)=
To enter Edit sub-menu for editing STAT editor screen contents
To enter S-Sum sub-menu (calculating sum)
To enter S-Var sub-menu (calculating variable)
To enter S-PTS sub-menu (calculating points)
To enter Reg sub-menu (Regression calculation)
•
•
•
•
•
•
81.2
2-variable Minimum value of Y
STAT only Maximum value of Y
For non-Quad Regression coefficient A
minY
[4] S-SUM
[5] S-VAR
[6] S-PTS
[7] Reg
x
n
maxY
f(x)= X3+3X2-2X
press
,
to restart the calculator.
5.528109984
6.180614856
Reg
A
B
r
FUNCTION (x,y) TABLE CALCULATION
Input f(x) function to generate the function table for x & f(x).
Steps to generate a Number Table
1. Enter TABLE Mode
x
n-1
Reg
Regression coefficient B
Correlation coefficient r
Estimated value of x
Estimated value of y
Never expose the battery to high temperatures, direct
heat, or dispose by incineration.
x
Quadratic Regression type Statistical Calculation Example:
ABC Company investigate the effectiveness of the
advertisement expense in coded units, the following data were
obtained:
• Press
to enter the Table function calculation.
y
Never leave a dead battery in the calculator as the dead
battery may leak and cause damage to the calculator.
Continue using the calculator in the low battery condition
may have improper operation or the stored memory may
be corrupted or lost completely. Keep the written records
of important data all the time; and replace the battery as
soon as possible.
2. Function Input screen
• Input function with X variable (
Function Table Result.
Reg
For Quad Regression coefficient A
A
B
C
x1
x2
y
) to generate
Reg only
Regression coefficient B
Regression coefficient C
Estimated value of x1
Estimated value of x2
Estimated value of y
(EEA: Norway, Iceland and Liechtenstein)
• All other variables (A, B, C, D, Y) and independent
memory (M) act as the value.
• Pol, Rec, Q…r function not able to used in Function
Input screen.
• The Function Table Calculation will change X-variable.
Advertisement expenses: X
Effectiveness: y (%)
18
38
35
54
40
59
21
40
19
38
PUB NO. E-IE-410
Download from Www.Somanuals.com. All Manuals Search And Download.
35 36
31
32
33
34
37
38
39
40
|