TRXI-22A, TRXI-24A, TRXI-42A,
AND TRXI-44A ACTIVE
TOKEN RING INTELLIGENT HUB
USER’S GUIDE
CABLETRON SYSTEMS, P. O. Box 5005, Rochester, NH 03867-0505
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTICE
F CC NOTICE
This device complies with Part 15 of the FCC rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment uses, generates, and can radiate
radio frequency energy and if not installed in accordance with the operator’s manual,
may cause harmful interference to radio communications. Operation of this equipment
in a residential area is likely to cause interference in which case the user will be required
to correct the interference at his own expense.
WARNING: Changes or modifications made to this device which are not expressly
approved by the party responsible for compliance could void the user’s authority to
operate the equipment.
DOC NOTICE
This digital apparatus does not exceed the Class A limits for radio noise emissions from
digital apparatus set out in the Radio Interference Regulations of the Canadian
Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les
limites applicables aux appareils numériques de la class A prescrites dans le Règlement
sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
CABLETRON SYSTEMS, INC. P ROGRAM LICENSE AGREEMENT
IMPORTANT: Before utilizing this product, carefully read this License Agreement.
This document is an agreement between you, the end user, and Cabletron Systems, Inc.
(“Cabletron”) that sets forth your rights and obligations with respect to the Cabletron
software program (the “Program”) contained in this package. The Program may be
contained in firmware, chips or other media. BY UTILIZING THE ENCLOSED
PRODUCT, YOU ARE AGREEING TO BECOME BOUND BY THE TERMS OF THIS
AGREEMENT, WHICH INCLUDES THE LICENSE AND THE LIMITATION OF
WARRANTY AND DISCLAIMER OF LIABILITY. IF YOU DO NOT AGREE TO THE
TERMS OF THIS AGREEMENT, PROMPTLY RETURN THE UNUSED PRODUCT TO
THE PLACE OF PURCHASE FOR A FULL REFUND.
CABLETRON SOF TWARE P ROGRAM LICENSE
1. LICENSE. You have the right to use only the one (1) copy of the Program provided
in this package subject to the terms and conditions of this License Agreement.
You may not copy, reproduce or transmit any part of the Program except as
permitted by the Copyright Act of the United States or as authorized in writing by
Cabletron.
ii
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTICE
2. OTHER RESTRICTIONS. You may not reverse engineer, decompile, or
disassemble the Program.
3. APPLICABLE LAW. This License Agreement shall be interpreted and governed
under the laws and in the state and federal courts of New Hampshire. You accept
the personal jurisdiction and venue of the New Hampshire courts.
EXCLUSION OF WARRANTY AND DISCLAIMER OF LIABILITY
1. EXCLUSION OF WARRANTY. Except as may be specifically provided by
Cabletron in writing, Cabletron makes no warranty, expressed or implied,
concerning the Program (including Its documentation and media).
CABLETRON DISCLAIMS ALL WARRANTIES, OTHER THAN THOSE
SUPPLIED TO YOU BY CABLETRON IN WRITING, EITHER EXPRESS OR
IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF
MERCHANTABLITY AND FITNESS FOR A PARTICULAR PURPOSE, WITH
RESPECT TO THE PROGRAM, THE ACCOMPANYING WRITTEN MATERIALS,
AND ANY ACCOMPANYING HARDWARE.
2. NO LIABILITY FOR CONSEQUENTIAL DAMAGES. IN NO EVENT SHALL
CABLETRON OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES
WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS
OF BUSINESS, PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS
INFORMATION, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR RELIANCE
DAMAGES, OR OTHER LOSS) ARISING OUT OF THE USE OR INABILITY TO
USE THIS CABLETRON PRODUCT, EVEN IF CABLETRON HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. BECAUSE SOME
STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY
FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, OR ON THE DURATION
OR LIMITATION OF IMPLIED WARRANTEES IN SOME INSTANCES THE
ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO YOU.
UNITED STATES GOVERNMENT RESTRICTED RIGHTS
The enclosed product (a) was developed solely at private expense; (b) contains “restricted
computer software” submitted with restricted rights in accordance with Section 52227-
19 (a) through (d) of the Commercial Computer Software - Restricted Rights Clause and
its successors, and (c) in all respects is proprietary data belonging to Cabletron and/or its
suppliers.
For Department of Defense units, the product is licensed with “Restricted Rights” as
defined in the DoD Supplement to the Federal Acquisition Regulations, Section 52.227-
7013 (c) (1) (ii) and its successors, and use, duplication, disclosure by the Government is
subject to restrictions as set forth in subparagraph (c) (1) (ii) of the Rights in Technical
Data and Computer Software clause at 252.227-7013. Cabletron Systems, Inc., 35
Industrial Way. Rochester, New Hampshire 03867
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
TABLE OF CONTENTS
CHAP TER 1 INTRODUCTION
1.1 USING THIS MANUAL ............................................................ 1-1
1.2 GETTING HELP ........................................................................ 1-2
1.3 TRXI ACTIVE CONCENTRATOR OVERVIEW...................... 1-2
1.4 TRXI FEATURES ...................................................................... 1-3
1.5 REMOTE NETWORK MANAGEMENT CAPABILITIES ...... 1-6
1.6 RECOMMENDED READING................................................... 1-6
CHAP TER 2 REQUIREMENTS/SP ECIF ICATIONS
2.1 CABLE SPECIFICATIONS....................................................... 2-1
2.1.1 UTP Cable Specifications for the TRXI-22A/24A
Lobe Ports and TPIM-T2 .............................................. 2-2
2.1.2 STP Cable Specifications For The TRXI-42A/44A
Lobe Ports and TPIM-T1/T4......................................... 2-4
2.1.3 Mixed Cable Types ........................................................ 2-6
2.1.4 Multimode Fiber Optic Cable Specifications for
the TPIM-F2 .................................................................. 2-7
2.1.5 Single Mode Fiber Optic Cable Specifications for
the TPIM-F3 .................................................................. 2-8
2.2 CABLE RECOMMENDATIONS/TROUBLESHOOTING....... 2-9
2.3 COM 1/COM 2 PORT SPECIFICATIONS.............................. 2-11
2.4 TPIM SPECIFICATIONS........................................................ 2-12
2.5 GENERAL SPECIFICATIONS ............................................... 2-17
CHAP TER 3 INSTALLATION
3.1 UNPACKING THE TRXI .......................................................... 3-1
3.2 ATTACHING THE STRAIN RELIEF BRACKET ................... 3-1
3.3 INSTALLING THE TRXI .......................................................... 3-2
3.3.1 Rack Mounting the TRXI.............................................. 3-3
3.3.2 Wall Mounting the TRXI .............................................. 3-4
3.3.3 Free-Standing Installation ........................................... 3-5
3.4 SETTING THE RING SPEED SWITCH .................................. 3-6
3.5 SETTING THE NVRAM SWITCH ........................................... 3-7
3.6 CONNECTING THE TRXI TO THE POWER SOURCE......... 3-8
3.7 CONNECTING THE NETWORK LOBE PORT CABLING .... 3-8
3.8 INSTALLING THE TPIM RI/RO MODULES........................ 3-11
v
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
3.8.1 Setting the TPIM’s Phantom Switch and
RI/RO Switch ...............................................................3-12
3.8.2 Installing a TPIM to the TRXI....................................3-13
3.8.3 Connecting a Twisted Pair Segment to
the TPIM-T1 ................................................................3-14
3.8.4 Connecting a Twisted Pair Segment to
the TPIM-T2 or TPIM-T4............................................3-15
3.8.5 Connecting a Fiber Optic Link Segment to
the TPIM-F2 or TPIM-F3............................................3-16
3.9 FINISHING THE INSTALLATION........................................3-18
CHAP TER 4 TESTING AND TROUBLESHOOTING
4.1 CHECKING THE INSTALLATION..........................................4-1
4.2 USING LANVIEW LEDs ...........................................................4-2
4.3 USING THE LCD DISPLAY .....................................................4-3
4.3.1 Static System Messages ................................................4-4
4.3.2 Alarm Messages.............................................................4-5
4.3.3 Unsaved Initialization Messages..................................4-6
4.3.4 Saved System Messages ................................................4-7
CHAP TER 5 LOCAL MANAGEMENT
5.1 MANAGEMENT TERMINAL REQUIREMENTS ...................5-2
5.1.1 Attaching the Management Terminal..........................5-2
5.1.2 Setting the Management Terminal Setup
Parameters.....................................................................5-3
5.1.3 Modem Cable Configuration and Setup .......................5-4
5.2 ACCESSING LOCAL MANAGEMENT ....................................5-5
5.3 USING LOCAL MANAGEMENT..............................................5-6
5.3.1 The System Level Screen ..............................................5-8
5.3.2 The SNMP Community Names Screen ......................5-13
5.3.3 The SNMP Traps Screen .............................................5-15
5.3.4 The Ring Security Screen ............................................5-17
5.3.5 The Device Statistics Screen .......................................5-22
5.3.6 The Chassis Status View Screen ................................5-28
5.3.7 The Component Status View Screen ..........................5-30
5.3.8 The SNMP Tools Screen ..............................................5-31
vi
Download from Www.Somanuals.com. All Manuals Search And Download.
INTRODUCTION
CHAP TER 1
INTRODUCTION
Welcome to the Cabletron Systems TRXI-22A, TRXI-24A, TRXI-42A,
a n d TRXI-44A Active Tok en Rin g In telligen t Hu b User ’s Gu id e.
This manual provides installation instructions, network
requirements, and reference information for the TRXI Active
stand-alone concentrator. You should have an understanding of Token
Ring (IEEE 802.5) type data communications networks and their
physical layer components before installing the TRXI.
Note: This manual uses the term TRXI to describe the TRXI -22A, 24A,
42A, and 44A unless otherwise specified.
1.1 USING THIS MANUAL
The following summary provides information about each chapter in
this manual. Read through the summary to familiarize yourself with
this manual’s organization and content.
Chapter 1, In tr od u ction , outlines the contents of this manual and
describes features of the TRXI. It also lists recommended reading for
implementing a Token Ring network.
Chapter 2, Requ ir em en ts/Sp ecifica tion s, describes cabling
requirements, network guidelines, and TRXI operating specifications.
Chapter 3, In sta lla tion , contains instructions for installing your
TRXI and connecting it to the network using the various media types.
This chapter includes instructions for setting the Ring Speed Switch,
setting the NVRAM Switch, installing the TPIMs, and setting the
TPIM Phantom Switch.
Chapter 4, Testin g a n d Tr ou blesh ootin g, contains procedures for
testing the TRXI after installation, a description of the LANVIEW®
LEDs, and explains the front panel LCD display.
Chapter 5, Loca l Ma n a gem en t, describes how to access Local
Management. It also describes each of the Local Management screens
and the available commands.
Page 1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
INTRODUCTION
1.2 GETTING HELP
If you need additional support related to the Cabletron Systems TRXI,
or if you have any questions, comments, or suggestions concerning this
manual, contact Cabletron Systems Technical Support:
By phone ......................... (603) 332-9400
Monday-Friday; 8am - 8pm EST
®
By CompuServe ............ GO CTRON from any ! prompt
By Internet mail ............. support@ctron.com
1.3 TRXI ACTIVE CONCENTRATOR OVERVIEW
The TRXI stand-alone concentrator provides 12 or 24 RJ 45 active
Trunk Coupling Units (TCUs) for Shielded Twisted Pair (STP) or
Unshielded Twisted Pair (UTP) network lobe connections. The
TRXI-22A, 24A, 42A, and 44A are functionally identical with the
exception of the TCU lobe ports. Cabletron offers the following TRXI
configurations:
•
•
•
•
TRXI-22A, twelve active RJ 45 TCU lobe ports that support
category 3, 4, and 5 UTP cabling.
TRXI-24A, twenty-four active RJ 45 TCU lobe ports that
support category 3, 4, and 5 UTP cabling.
TRXI-42A, twelve active RJ 45 TCU lobe ports that support
IBM Type 1, 2, 6, and 9 STP cabling.
TRXI-44A, twenty-four active RJ 45 TCU lobe ports that
support IBM Type 1, 2, 6, and 9 STP cabling.
RO
TRXI-24A TOKEN RING HUB WITH LANVIEW®
24 23 22 21 20 19
18 17 16 15 14 13
18
17
16
15
14
13
24
23
11
22
10
21
20
19
12 11 10
9
8
7
1
RO
RI
PWR
ACT
CPU 16 Mb/s
MGMT
DISPLAYRESET
6
5
4
3
2
6
5
4
3
2
1
12
9
8
7
COM 2 COM 1
RI
Figure 1-1. The TRXI-24A
Page 1-2
Download from Www.Somanuals.com. All Manuals Search And Download.
INTRODUCTION
You can upgrade the TRXI-22A and TRXI-42A to twenty-four ports
using a twelve port upgrade kit available from Cabletron Systems
(Cabletron Part Number TRXI-24A-UGKIT or TRXI-44A-UGKIT).
The TRXI provides two additional ports for Ring In and Ring Out
(RI/RO) connections. These ports support Cabletron’s Token Ring Port
Interface Modules (TPIMs). TPIMs provide full repeater functionality.
They are not included with the TRXI, but can be ordered separately
from Cabletron. Table 1-1 lists each TPIM.
1.4 TRXI F EATURES
Active TCU P or ts
The active TCU ports regenerate, reshape and filter the incoming
signal permitting UTP lobe cable lengths of up to 100 m eter s and STP
lobe cable lengths up to 150 m eter s at 16 Mbps ring speed.
Ca ble Sign a l P ola r ity
Differential Manchester encoding is utilized for each of the
concentrator module TCU ports. This permits passing data regardless
of receive link polarity.
Note: If a reversed polarity condition is discovered, the segment should
be removed from the network and wired correctly (according to the
connector wiring shown in Chapter 2, Requirements / Specifications).
This will avoid the potential for future compatibility problems.
Sp eed F a u lt P r otection
If a station attempts to insert into the ring at a ring speed
(4 or 16 Mbps) different from what is set on the TRXI, that port is
automatically bypassed to prevent the ring from beaconing. The Lobe
Port Status LED blinks indicating the port with the speed fault is
bypassed.
Loca l Ma n a gem en t
Local Management provides the tools to manage the TRXI and all of
its attached segments. You access Local Management by connecting a
Digital Equipment Corporation VT™ 320 series terminal or a PC
using VT320 emulation software to the TRXI’s COM 1 port.
Page 1-3
Download from Www.Somanuals.com. All Manuals Search And Download.
INTRODUCTION
Tok en Rin g P or t In ter fa ce Mod u les
TPIMs are optional features that let you expand your trunk
connections using different media types. TPIMs have embedded
repeaters and retime all data. Cabletron offers a variety of TPIMs for
trunk Ring In or Ring Out connections. Table 1-2 lists each TPIM.
Table 1-1. TPIMs
TP IM
Med ia Typ e
Con n ector
TPIM-T1
TPIM-T2
TPIM-T4
TPIM-F2
TPIM-F3
Shielded Twisted Pair
Unshielded Twisted Pair
Shielded Twisted Pair
Multimode Fiber Optic
Single mode Fiber Optic
DB9
RJ 45
RJ 45
ST
ST
Rin g Sp eed Sw itch
The Ring Speed Switch lets you select ring speeds of either 4 Mbps or
16 Mbps. The factory default setting is 16 Mbps.
F la sh EEP ROMs
The TRXI uses Flash EEPROMs that allow you to download new and
updated firmware using Cabletron System’s Remote LANVIEW/
Windows, version 2.3 or later or any device using BOOTP or TFTP
protocols.
LANVIEW LEDs
Cabletron Systems’ LANVIEW LED Status Monitoring and
Diagnostics System is a convenient troubleshooting tool that helps you
diagnose power failures, RI/RO status, cable faults, ring speed, link
problems, and network activity.
Ca bletr on ’s Distr ibu ted LAN Mon itor
Cabletron Systems’ Distributed LAN Monitor (DLM) is a software
option for the TRXI. DLM provides a method for locally polling and
monitoring devices on a local area network to minimize network
management traffic on an enterprise, campus, or wide area network.
Page 1-4
Download from Www.Somanuals.com. All Manuals Search And Download.
INTRODUCTION
RMON MIB Su p p or t
The TRXI supports the RMON MIB RFC 1271/1513 Token Ring
Extensions shown in Table 1-2.
Table 1-2. RMON MIB RFC 1271/1513 Support
Gr ou p
Su bgr ou p
Section
Statistics
rmon 1
Token Ring ML Stats Table
statistics 2
History
rmon 2
History Control Table
Token Ring ML History Table
Alarm Table
history 1
history 3
alarm 1
Alarm
rmon 3
Event
Event Table
event 1
rmon 9
Log Table
event 2
Token Ring
rmon 10
Ring Station Control Table
Ring Station Table
token ring 1
token ring 2
token ring 3
token ring 4
token ring 5
Ring Station Order Table
Ring Station Config Control Table
Ring Station Config Table
COM P or t Ap p lica tion s
The front panel COM 1 port is configured to support Local
Management applications. Future capabilities for TRXI’s serial ports
include an SNMP proxy for Uninterruptible Power Supplies (UPS),
the Serial Line Internet Protocol (SLIP), and Modem.
LCD a n d Reset Bu tton
The LCD provides status information about the TRXI such as power
up diagnostics, revision levels, serial numbers, and error alerts. The
TRXI also has a Reset Button to initialize the processor. Both the LCD
and the Reset Button are located on the front panel of the TRXI.
Page 1-5
Download from Www.Somanuals.com. All Manuals Search And Download.
INTRODUCTION
1.5 REMOTE NETWORK MANAGEMENT CAP ABILITIES
You can control and manage the TRXI using any Simple Network
Management Protocol (SNMP) software. Cabletron Systems offers the
following remote management packages:
®
•
•
•
Cabletron Systems SPECTRUM
®
Cabletron Systems Remote LANVIEW /Windows™
®
Cabletron Systems Remote SPECTRUM Portable
Management Applications
The TRXI remote network management capabilities provide the
necessary management tools for the TRXI to operate at its full
capacity. Your ability to set up parameters with network management
ensures optimal performance of the TRXI.
1.6 RECOMMENDED READING
The following publications are recommended if more information is
required on implementing a token ring network.
Loca l Ar ea Netw or k s, Tok en Rin g Access Meth od , IEEE
Sta n d a r d 802.5 (1989)
Com m er cia l Bu ild in g Wir in g Sta n d a r d , EIA Sta n d a r d
P r op osa l No. 1907-B (if approved, to be published as EIA/TIA-568)
LAN Tr ou blesh ootin g Ha n d book , Mark Miller (1989, M&T
Publishing)
Page 1-6
Download from Www.Somanuals.com. All Manuals Search And Download.
REQUIREMENTS/SP ECIF ICATIONS
CHAP TER 2
REQUIREMENTS/SP ECIF ICATIONS
This chapter describes cabling requirements, power requirements, and
operating specifications for the TRXI. Be sure that you read this
chapter before you install the TRXI. Your network must meet the
requirements and conditions specified in this chapter to obtain
satisfactory performance from this equipment. Failure to follow these
guidelines could result in poor network performance.
2.1 CABLE SP ECIF ICATIONS
The basic concept of a token ring is a set of Trunk Coupling Units
(TCUs) connected by trunk cabling. You can extend the trunk cabling
by installing TPIMs into the TRXI’s RI/RO ports. TPIMs have
embedded repeaters and provide trunk connections for UTP, STP,
Multimode Fiber, and Single Mode Fiber cabling.
You attach stations to the TCU lobe ports with lobe cabling. Figure 2-1
shows the various ports and cables.
Ring Out TPIM
TRXI-24A TOKEN RING HUB WITH LANVIEW®
RO
RI
TCU Lobe Ports
Lobe Cabling
Trunk Cabling
Token Ring Station
Ring In TPIM
TRXI-24A TOKEN RING HUB WITH LANVIEW®
RO
RI
Figure 2-1. TRXI Ports/Cables
Page 2-1
Download from Www.Somanuals.com. All Manuals Search And Download.
REQUIREMENTS/SP ECIF ICATIONS
2.1.1 UTP Ca ble Sp ecifica tion s for th e TRXI-22A/24A Lobe
Por ts a n d TP IM-T2
The TRXI-22A and TRXI-24A lobe ports and the TPIM-T2 support
voice grade Unshielded Twisted Pair (UTP) cable, as described in
EIA/TIA TSB 568, and IBM Type 3 cable.
UTP consists of four pairs of 24 AWG solid wire for data or voice
communication and is typically used to wire cable runs within the
walls of buildings. In some installations, existing UTP building wiring
can be used for token ring cabling. UTP cable must conform to the
limits shown in Table 2-1.
Wa r n in g: DO NOT connect UTP cabling to any non-token ring network
conductors (telephone, etc.) or ground. If in doubt, test wiring before
using. Telephone Battery and Ringing voltages, used in UTP telephone
circuits, could present a shock hazard and can damage token ring
equipment when connected to token ring cabling.
The increased popularity and cost advantages of UTP cable have
driven refinements to UTP cable design. As a result, better grades of
UTP cable, known as supergrade or level 4, are available that exhibit
improved transmission characteristics. These improved grades of UTP
can often be used to permit operation at 16 Mbps on longer lobe cables.
Atten u a tion a n d Im p ed a n ce
The values listed in Table 2-1 include the maximum attenuation of the
cables, connectors, patch panels, and reflection losses due to
impedance mismatches in the segment.
Table 2-1. UTP Voice Grade and Category 3 Specifications
F r equ en cy
Im p ed a n ce
Atten u a tion
1 MHz
4 MHz
10 MHz
16 MHz
100Ω ±15%
100Ω ±15%
100Ω ±15%
100Ω ±15%
<26 dB/km (8 dB/1000 ft)
<56 dB/km (16 dB/1000 ft)
<98 dB/km (30 dB/1000 ft)
<131 dB/km (40 dB/1000 ft)
Page 2-2
Download from Www.Somanuals.com. All Manuals Search And Download.
REQUIREMENTS/SP ECIF ICATIONS
Ma xim u m Lobe Len gth s
The lobe length is the physical length of the cable connecting a station
to its TCU port at the TRXI. Table 2-2 shows the maximum lobe
length, according to ring speed. The cable lengths listed in Table 2-2
are total lengths made up of UTP cable only.
Table 2-2. UTP Maximum Lobe Lengths
UTP Ca ble Typ e
Ma xim u m Lobe Len gth
4 Mbp s
16 Mbp s
Category 3
Category 4
Category 5
200 meters
(656 feet)
100 meters
(328 feet)
200 meters
(656 feet)
100 meters
(328 feet)
250 meters
(820 feet)
120 meters
(394 feet)
Typ e 3 Med ia F ilter s
To connect a UTP lobe segment from a TRXI-22A or TRXI-24A to a
station supporting STP cabling, you need a Type 3 Media Filter.
Cabletron Systems offers the following Type 3 Media Filters:
•
•
TRMF, RJ 45 (UTP) connector to 10-inch DB9 (STP) cable with
LANVIEW
TRMF -2, RJ 45 (UTP) connector to DB9 (STP) connector
Ma xim u m Nu m ber of Sta tion s
When you use UTP lobe cabling anywhere on the ring, the number of
stations is limited to 150 sta tion s at ring speeds of either
4 or 16 Mbps.
Page 2-3
Download from Www.Somanuals.com. All Manuals Search And Download.
REQUIREMENTS/SP ECIF ICATIONS
2.1.2 STP Ca ble Sp ecifica tion s For Th e TRXI-42A/44A Lobe
Por ts a n d TP IM-T1/T4
The TRXI-42A and TRXI-44A lobe ports support IBM Type 1, 2, 6, and
9 STP cabling as described below:
•
•
IBM Typ e 1 - Two STP lengths of 22 AWG solid wire for data.
Used for the longest cable runs within the walls of buildings.
IBM Typ e 2 - Similar to Type 1 data cable, but having four
additional UTP lengths of 22 AWG solid wire carried outside of
the shield casing. Typically used for voice communication and
often used to wire cable runs within the walls of buildings.
•
•
IBM Typ e 6 - Two STP lengths of 26 AWG stranded wire for
data. This type is used in patch panels or to connect devices
to/from wall jacks. Attenuation for Type 6 cable is 3/2 x Type 1
cable (66 m of Type 6 =100 meters of Type 1).
IBM Typ e 9 - Similar to Type 1, but uses 26 AWG solid wire.
Attenuation for Type 9 cable is 3/2 x Type 1 cable
(66 m of Type 9 = 100 meters of Type 1).
Atten u a tion a n d Im p ed a n ce
The attenuation values shown in Table 2-3 include the attenuation of
the cables, connectors, patch panels, and reflection losses due to
impedance mismatches in the segment.
Table 2-3. STP Cable Specifications
F r equ en cy
Im p ed a n ce
Atten u a tion
Types 1 & 2
4 MHz
16 MHz
150Ω + 15%
150Ω + 15%
<22 dB/km (6.7 db/1000 ft.)
<45 dB/km (13.7 db/1000 ft.)
Types 6 & 9
4 MHz
16 MHz
150Ω + 15%
150Ω + 15%
<33 dB/km (10 db/1000 ft.)
<66 dB/km (20 db/1000 ft.)
Page 2-4
Download from Www.Somanuals.com. All Manuals Search And Download.
REQUIREMENTS/SP ECIF ICATIONS
Ma xim u m Lobe Len gth s
The lobe length is the physical length of the cable connecting a station
to its TCU port at the TRXI. Table 2-4 shows the maximum lobe
length, according to ring speed. The cable lengths listed in Table 2-4
are total lengths made up of STP cable only.
Table 2-4. STP Maximum Lobe Lengths
STP Ca ble Typ e
Rin g Sp eed
4 Mbp s
16 Mbp s
IBM Types 1 & 2
300 meters
(984 feet)
150 meters
(492 feet)
IBM Types 6 & 9 (only
for station to wall jack
and patch panels)
30 meters
(99 feet)
30 meters
(99 feet)
Ma xim u m Tr u n k Len gth s
The maximum trunk cable length between the TRXI and another
active device is equal to the maximum drive distance as shown in
Table 2-5. When the neighboring token ring device is a passive device,
the combined length of twice the longest trunk cable plus the longest
lobe cable attached to the passive ring segment cannot exceed the
Maximum Drive Distance.
Table 2-5. STP Maximum Drive Distance
STP Ca ble Typ e
Rin g Sp eed
4 Mbp s
16 Mbp s
IBM Types 1 & 2
IBM Types 6 & 9
770 meters
(2525 feet)
346 meters
(1138 feet)
513 meters
(1683 feet)
230 meters
(755 feet)
Ma xim u m Nu m ber of Sta tion s
When you use STP lobe cabling everywhere on the ring, the TRXI can
support up to 250 sta tion s at ring speeds of either 4 or 16 Mbps.
Page 2-5
Download from Www.Somanuals.com. All Manuals Search And Download.
REQUIREMENTS/SP ECIF ICATIONS
2.1.3 Mixed Ca ble Typ es
If you mix cable types in your installation, you must compensate for
the different cable attenuations. Type 6 and Type 9 cables can be run
for only 2/3 the distance of Type 1. This means:
10 meters (Type 1) ≈ 6.6 meters (Types 6, 9)
Exa m p le: Maximum Length for Mixed Cabling Installation
-
-
-
16 Mbps ring speed and 130 stations.
The building has 60 meters of Type 1 cable in the wall.
How much Type 6 cable is available to connect the repeater
TCU port to the patch panel and the station to the local
wall jack?
-
Type 6 can only go 2/3 the distance of Type 1.
Solu tion :
100 meters = maximum cable length if only Type 1 cable is used
[60 meters of Type 1] + [40 meters of Type 1] = max. length
[60 meters of Type 1] + [(.66) x (40 meters) of Type 6] = max. length
|
|
26.4 meters of Type 6 (for patch panel and wall jack
connections)
Page 2-6
Download from Www.Somanuals.com. All Manuals Search And Download.
REQUIREMENTS/SP ECIF ICATIONS
2.1.4 Mu ltim od e Fiber Op tic Ca ble Sp ecifica tion s for th e
TP IM-F 2
Table 2-6 shows Multimode Fiber Optic Cable specifications for the
TPIM-F2.
Table 2-6. Multimode Fiber Optic Cable Specifications
Ca ble Typ e
Atten u a tion
Ma xim u m Dr ive Dista n ce
50/125 µm
62.5/125 µm
100/140 µm
13.0 dB or less The maximum allowable fiber op-
tic cable length is 2 km (2187.2
16.0 dB or less
yards). However, IEEE 802.5
specifications allow for a maxi-
mum of 1 km (1093.6 yards).
19.0 dB or less
Ma xim u m Tr u n k Len gth s
The maximum trunk cable length between the TRXI and another
active device is equal to the maximum drive distance as shown in
Table 2-6. When the neighboring token ring device is a passive device,
the combined length of twice the longest trunk cable plus the longest
lobe cable attached to the passive ring segment cannot exceed the
Maximum Drive Distance Trunk Length.
Atten u a tion
The fiber optic cable must be tested with a fiber optic attenuation test
set that is adjusted for an 850 nm wavelength. This test verifies that
the signal loss in a cable is within an acceptable level. Table 2-6 shows
the attenuation for each Multimode cable type.
F iber Op tic Bu d get
When determining the maximum fiber optic cable length, the fiber
optic budget delay should be calculated and taken into consideration
before fiber optic cable runs are incorporated in any network design.
Fiber optic budget is the combination of the optical loss due to the
fiber optic cable, in-line splices, and fiber optic connectors.
Page 2-7
Download from Www.Somanuals.com. All Manuals Search And Download.
REQUIREMENTS/SP ECIF ICATIONS
2.1.5 Sin gle Mod e Fiber Op tic Ca ble Sp ecifica tion s for th e
TP IM-F 3
Table 2-7 shows Single Mode Fiber Optic Cable specifications for the
TPIM-F3.
Table 2-7. Single Mode Fiber Optic Cable Specifications
Ca ble Typ e
Atten u a tion
Ma xim u m Dr ive Dista n ce
8/125-12/125 µm 10.0 dB or less The max. allowable fiber optic
cable length is 2 km (2187.2
yards). However, IEEE 802.5
specs allow for a max. of 1 km
(1093.6 yards).
Ma xim u m Tr u n k Len gth s
The maximum trunk cable length between the TRXI and another
active device is equal to the Maximum Drive Distance as shown in
Table 2-7. When the neighboring token ring device is a passive device,
the combined length of twice the longest trunk cable plus the longest
lobe cable attached to the passive ring segment cannot exceed the
Maximum Drive Distance Trunk Length.
Atten u a tion
The fiber optic cable must be tested with a fiber optic attenuation test
set that is adjusted for a 1300 nm wavelength. This test verifies that
the signal loss in a cable is within an acceptable level of 10 dB or less
for any given single mode fiber optic link.
F iber Op tic Bu d get
Fiber optic budget is the combination of the optical loss due to the
fiber optic cable, in-line splices, and fiber optic connectors. When
determining the maximum fiber optic cable length, the fiber optic
budget (total loss of 10.0 dB or less between stations) and total
network propagation delay should be calculated and considered before
fiber optic cable runs are incorporated in any network design.
Page 2-8
Download from Www.Somanuals.com. All Manuals Search And Download.
REQUIREMENTS/SP ECIF ICATIONS
2.2 CABLE RECOMMENDATIONS/TROUBLESHOOTING
The following sections describe common cable problems and
recommendations for correcting them.
Cr ossta lk
Crosstalk is interference caused by signal coupling between the
different cable pairs contained within a multi-pair cable bundle.
Multi-pair cables should not be used for UTP lobe cabling. UTP lobe
cabling should be dedicated to carrying token ring traffic. Avoid
mixing token ring signals with other applications (voice, etc.) within
the same cable.
Noise
Noise can be caused by either crosstalk or externally induced
impulses. If noise induced errors are suspected, it may be necessary to
reroute cabling away from potential noise sources (motors, switching
equipment, fluorescent lighting, high amperage equipment), or to
ensure that the electrical wiring in the area is properly wired and
grounded.
Tem p er a tu r e
The attenuation of PVC insulated cable varies significantly with
temperature. Plenum-rated cables are strongly recommended at
temperatures greater than 40˚C to ensure that cable attenuation
remains within specification. Check the cable manufacturer’s
specifications.
In addition to complying with the preceding cable specifications, the
following recommendations should be followed to minimize errors and
help to obtain optimum performance from your network:
•
•
UTP cabling should be free of splices, stubs or bridged taps.
No more than two punch-down blocks between TCU ports and
wall outlets.
•
Metal troughs, ducts, etc. carrying token ring signals should be
properly grounded.
Page 2-9
Download from Www.Somanuals.com. All Manuals Search And Download.
REQUIREMENTS/SP ECIF ICATIONS
•
Token ring signals should not be routed through copper cables
that exit a building or which are adjacent to cables either
exiting a building or exposed to lightning strikes and power
surges.
•
UTP cables that contain token ring signals should not be
simultaneously used for applications which may impress high
voltages (greater that 5 volts) with sharp rise or fall times,
since the noise coupling from such signals could directly cause
errors on the token ring network.
•
•
For single telecommunications closet rings, lobe lengths should
not exceed 100 meters or 22 to 24 AWG wire from the attaching
device and the TCU port.
When possible, use dedicated UTP cable for token ring signals.
Page 2-10
Download from Www.Somanuals.com. All Manuals Search And Download.
REQUIREMENTS/SP ECIF ICATIONS
2.3 COM 1/COM 2 P ORT SP ECIF ICATIONS
The RJ 45 COM 1 and COM 2 ports support Console, Modem, UPS,
and SLIP applications. A description of each COM port application is
listed below:
Note: Console is the only COM port application available at this time.
Modem, UPS, and SLIP applications will be available in future TRXI
releases.
TRXI-24A TOKEN RING HUB WITH LANVIEW®
DISPLAY RESET
COM 2
COM 1
Figure 2-2. COM 1/COM 2 Ports
Con sole
The COM 1 port, as default, supports access to a Local Management
Console. The console supports a Digital Equipment Corporation VT
320™ terminal or PC emulation of the VT 320 terminal.
Mod em
Both the COM 1 and COM 2 ports support access to Local
Management using a modem.
UP S
The COM 2 port supports an Uninterruptible Power Supply
(American Power Conversion only).
SLIP
The COM 1 and COM 2 ports support the Serial Line Internet
Protocol.
Page 2-11
Download from Www.Somanuals.com. All Manuals Search And Download.
REQUIREMENTS/SP ECIF ICATIONS
2.4 TP IM SP ECIF ICATIONS
TPIMs provide Ring In/Ring Out (RI/RO) connections that let you
extend your network using a variety of media. Each TPIM has an
embedded repeater that retimes all data.
The LNK (Link) LED on each TPIM provides the following
information:
•
•
•
Green - RI or RO active
Red (TPIM-T1/T2/T4 only) - No Link (Autowrapped)
Off - No Link (Wrapped or Disabled)
The following sections describe each TPIM.
TP IM-T1
The TPIM-T1 is a female DB9 connector that supports STP cabling.
Figure 2-3 shows TPIM-T1 pinouts for Ring Out and Ring In
applications.
5
4
3
2
1
LNK
9
8
7
6
TPIM-T1
RING IN
RING OUT
1. Receive +
2. Ground
1. Transmit +
2. Ground
3. +5V at 250 mA
4. Ground
3. +5V at 250 mA
4. Ground
5. Transmit -
6. Receive -
7. Ground
5. Receive -
6. Transmit -
7. Ground
8. Ground
8. Ground
9. Transmit +
9. Receive +
Figure 2-3. TPIM-T1 Pinouts
Page 2-12
Download from Www.Somanuals.com. All Manuals Search And Download.
REQUIREMENTS/SP ECIF ICATIONS
TP IM-T2
The TPIM-T2 is an RJ 45 connector that supports UTP cabling.
Figure 2-4 shows pinouts for Ring Out and Ring In applications.
1 2 3 4 5 6 7 8
LNK
TPIM-T2
RING IN
RING OUT
1. Not Used
2. Not Used
3. Receive -
4. Transmit +
5. Transmit -
6. Receive +
7. Not Used
8. Not Used
1. Not Used
2. Not Used
3. Transmit -
4. Receive +
5. Receive -
6. Transmit +
7. Not Used
8. Not Used
Figure 2-4. TPIM-T2 Pinouts
TP IM-T4
The TPIM-T4 is an RJ 45 connector that supports STP cabling.
Figure 2-5 shows pinouts for Ring Out and Ring In applications.
1 2 3 4 5 6 7 8
LNK
TPIM-T4
RING IN
RING OUT
1. Not Used
2. Not Used
3. Receive -
4. Transmit +
5. Transmit -
6. Receive +
7. Not Used
8. Not Used
1. Not Used
2. Not Used
3. Transmit -
4. Receive +
5. Receive -
6. Transmit +
7. Not Used
8. Not Used
Figure 2-5. TPIM-T4 Pinouts
Page 2-13
Download from Www.Somanuals.com. All Manuals Search And Download.
REQUIREMENTS/SP ECIF ICATIONS
TP IM-F 2
The TPIM-F2 shown in Figure 2-6 is an ST connector that supports
Multimode fiber Optic cabling.
RX
TX
LNK
TPIM-F2
Figure 2-6. The TPIM-F2
Note: The transmitter power levels and receive sensitivity levels given
are Peak Power Levels after optical overshoot. A Peak Power Meter must
be used to correctly compare the values given to those measured on any
particular port. If Power Levels are being measured with an Average
Power Meter, then 3 dBm must be added to the measurement to correctly
compare those measured values to the values listed (i.e. -30.5 dBm
peak=-33.5 dBm average).
P a r a m eter
Typ ica l
Va lu e
Wor st
Ca se
Wor st Ca se Typ ica l
Bu d get
Bu d get
Receive
Sensitivity:
-30.5 dBm -28.0 dBm
—
—
Peak Input
Power:
-7.6 dBm -8.2 dBm
—
—
Transmitter Power
50/125 µm
fiber:
-13.0 dBm -15.0 dBm 13.0 dB
-10.0 dBm -12.0 dBm 16.0 dB
-7.0 dBm -9.0 dBm 19.0 dB
17.5 dB
20.5 dB
23.5 dB
62.5/125 µm
fiber:
100/140 µm
fiber:
-10
Error Rate:
Better than 10
Page 2-14
Download from Www.Somanuals.com. All Manuals Search And Download.
REQUIREMENTS/SP ECIF ICATIONS
TP IM-F 3
The TPIM-F3 shown in Figure 2-7 is an ST connector that supports
Single Mode fiber Optic cabling.
RX
TX
LNK
TPIM-F3
Figure 2-7. The TPIM-F3
Note: Transmitter Power decreases as temperatures rise and increases
as temperatures fall. Use the Output Power Coefficient to calculate
increased or decreased power output for your operating environment.
For example, the typical power output at 25°C is -16.4 dBm. For a 4°C
temperature increase, multiply the typical coefficient
(-0.15 dBm) by four and add the result to typical output power
(4 x -0.15 dBm + -16.4 = -17.0).
Maximum Sensitivity (-36.0)
Receive
Sensitivity
Typical Sensitivity (-31.0)
Minimum Sensitivity (-30.0)
Minimum Receive Input (-9.72)
Typical Receive Input (-7.5)
Maximum
Receive
Input Power
Maximum Receive Input (-6.99)
Maximum Transmit Power (-12.0)
Typical Transmit Power (-15.5)
Transmitter Power*
(At 25°C into
8.3/125µm fiber)
Minimum Transmit Power (-21.0)
-40
-35
-30
-25
-20
-15
-10
-5
0
dBm
Less Power
More Power
* Transmit Power
Typical Power
Minimum Power
Maximum Power
Coefficient
(See Noe Below)
-0.15dBm/°C
-0.12 dBm/°C
-0.18 dBm/°C
Page 2-15
Download from Www.Somanuals.com. All Manuals Search And Download.
REQUIREMENTS/SP ECIF ICATIONS
P a r a m eter
Typ ica l
Min im u m
Ma xim u m
Transmitter Peak
Wave Length
1300 nm
60 nm
1270 nm
-
1330 nm
100 nm
Spectral Width
Rise Time/
Fall Time
3.0 nsec
2.5 nsec
2.7 nsec
2.2 nsec
5.0 nsec
5.0 nsec
Duty Cycle
50.1%
49.6%
50.7%
Bit Error Rate:
Better than 10-10
Note: The transmitter power levels given above are Peak Power Levels
after optical overshoot. You must use a Peak Power Meter to correctly
compare the values given above to those measured on any particular
port. If you are measuring power levels with an Average Power Meter,
add 3 dBm to the average power measurement to correctly compare the
average power values measured to the values listed above (i.e., -33.5
dBm average + 3 dB = -30.5 dBm peak).
Page 2-16
Download from Www.Somanuals.com. All Manuals Search And Download.
REQUIREMENTS/SP ECIF ICATIONS
2.5 GENERAL SP ECIF ICATIONS
The operating specifications for the TRXI are described in this section.
Cabletron Systems reserves the right to change these specifications at
any time without notice.
Data Buffer Memory (RAM):
Internal Processor:
Controller:
4 MB (Upgradeable)
Intel 80C960CA at 16 MHz
Texas Instruments TMS380
128 KB with battery back-up
128 KB
Static RAM:
EPROM:
FLASH MEMORY:
2 MB (Upgradeable)
P OWER SUP P LY REQUIREMENTS
Note: The TRXI has a universal power supply. This unit allows you to
use an input power from 85 to 264 VAC, 47-63 Hz.
The power supply has two outputs of +5 volts and +12 volts. The
maximum output power is 125 watts and the minimum efficiency is
65% under all conditions of line at full load. The minimum and
maximum load current from each output is shown below.
Ou tp u t
+5 Volts
+12 Volts
Min . Loa d
1.00 Amps
0.15 Amps
Ma x. Loa d
15 Amps
4 Amps
Ma x Pow er
75 Watts
48 Watts
ENVIRONMENTAL REQUIREMENTS
Operating Temperature:
Non-operating Temperature:
Operating Humidity:
+5° to +50°C
-30° to +90°C
5 to 95% (non-condensing)
Page 2-17
Download from Www.Somanuals.com. All Manuals Search And Download.
REQUIREMENTS/SP ECIF ICATIONS
SAF ETY
This unit meets the safety requirements of UL 1950, CSA C22.2
No. 950 and EN 60950; the EMI requirements of FCC Class A and
EN 55022 Class A; and the EMC requirements of EN 50082-1.
Wa r n in g: It is the responsibility of the person who sells the system to
which the TRXI will be a part to ensure that the total system meets
allowed limits of conducted and radiated emissions.
P HYSICAL
Dimensions:
Weight:
2.8H x 17.0W x 13.5D inches
(7.2H x 43.6W x 34.6D cm)
Unit:
7.95 pounds
Shipping:
11.95 pounds
SERVICE
MTBF
MTTR
>944,197 hours projected
<0.5 hour
Page 2-18
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
CHAP TER 3
INSTALLATION
This chapter outlines the procedure for installing a TRXI and
connecting it to a network. Be sure that your network meets the
guidelines and requirements outlined in Chapter 2, Requ ir em en ts/
Sp ecifica tion s, before installing the TRXI.
3.1 UNP ACKING THE TRXI
Unpack the TRXI as follows:
•
•
•
Remove the TRXI from the shipping box.
Slide the two foam end caps off the TRXI.
Remove the TRXI from the protective plastic bag and set it
aside to prevent damage.
•
Visually inspect the TRXI. If there are any signs of damage,
contact Cabletron Systems Technical Support immediately.
3.2 ATTACHING THE STRAIN RELIEF BRACKET
Attach the strain relief bracket to the front of the TRXI as follows:
1. Locate the strain relief bracket and four 8-32 x 3/8" screws from the
TRXI installation kit.
Ca u tion : Use of longer screws may cause damage to the unit or
electrical shock.
Page 3-1
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
2. Attach the strain relief bracket to the bottom of the TRXI as shown
in Figure 3-1.
TRXI-24A TOKEN RING HUB WITH LANVIEW®
Figure 3-1. Attaching the Strain Relief
3.3 INSTALLING THE TRXI
The TRXI can be rack mounted, wall mounted, or placed on any
horizontal surface. Select one of the following subsections and perform
the steps that are applicable for your installation. If you decide not to
install the TRXI in a 19-inch rack, the following requirements must be
met when selecting a location.
Note: Be sure that the location selected is within reach of the network
cabling.
•
•
•
•
An unrestricted free surface area at least 21 inches wide, 18
inches deep and 6 inches high is needed.
A single phase 85 to 264 Vac, 15A, grounded power receptacle
must be located within 7 feet of the site.
If a shelving unit is to be used, it must be able to support 30
pounds of static weight.
The temperature for the selected location must be maintained
between 5° and 50°C, and less than 10°C per hour temperature
change.
Page 3-2
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
3.3.1 Ra ck Mou n tin g th e TRXI
Refer to Figure 3-2 and perform these steps to install the TRXI in a
19-inch rack.
1. Remove four cover screws (two from each side) located along the
front edges of each side of the TRXI.
2. Using the four cover screws removed in step 1, attach the rack
mounting brackets to each end of the TRXI.
Wall/Rack Mounting
Brackets (2)
TRXI-24A TOKEN RING HUB WITH LANVIEW®
Screws (4)
Figure 3-2. Rack Mount Brackets Installation
3. With the mounting brackets installed, position the TRXI between
the vertical frame members of the 19-inch rack and fasten it
securely with the mounting screws (see Figure 3-3).
19-Inch Rack
TRXI-24A TOKEN RING HUB WITH LANVIEW®
Screws (4)
Figure 3-3. Installing the TRXI in the Rack
Page 3-3
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
3.3.2 Wa ll Mou n tin g th e TRXI
When you wall mount the TRXI, the cable connections must face
down. Perform the following steps to wall-mount the TRXI.
Note: 1/ 4-inch Molly screw anchors for wall mounting are not included
with the TRXI.
1. Use the supplied screws to attach the wall mounting brackets to
the bottom of the TRXI as shown in Figure 3-4. There are two
brackets, one for each side.
Molly Screw
Anchors
Molly Screws
Bracket Screws
Wall Mounting Bracket
Figure 3-4. Wall Mounting the TRXI
2. Select the wall location for the TRXI within 7 feet of a power outlet.
Wa r n in g: There is a potential SHOCK HAZARD if there is electrical
wiring within the wall that interferes with drilling for pilot holes. Select
a wall location where drilling pilot holes for the Molly screws will not
come in contact with electrical wiring in the wall.
Page 3-4
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
3. You will need a pencil for this step. With the wall mounting
brackets attached to the TRXI, position the TRXI against the wall
where it will be permanently mounted with the network port facing
down. Using a pencil, mark the wall location for the four pilot holes.
4. Set the TRXI aside and carefully drill four 1/4" pilot holes, one for
each of the Molly screw anchors and insert the four Molly screw
anchors into the holes just drilled.
5. Tighten each of the anchor screws until the anchor expands holding
the anchor firmly in the wall, then remove the screws completely.
6. Position the TRXI on the wall over the anchors and reinstall the
four anchor screws to attach the TRXI to the wall, as shown in
Figure 3-4. Tighten the four anchor screws.
3.3.3 Fr ee-Sta n d in g In sta lla tion
For a free-standing shelf or tabletop installation, locate the TRXI
within 7 feet of its power source and with an unrestricted free surface
area 21 inches wide, 18 inches deep and 6 inches high, as shown in
Figure 3-5.
21 IN.
18 IN.
TRXI-24A TOKEN RING HUB WITH LANVIEW®
6 IN.
7 FT.
Figure 3-5. Free-Standing Installation
Page 3-5
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
3.4 SETTING THE RING SP EED SWITCH
This section explains how to change the TRXI’s ring speed from the
factory default setting of 16 Mbps to 4 Mbps. To change the ring speed,
you need to set the switch located inside the TRXI as shown in
Figure 3-6. You can access the switch through the air vent with a
small screwdriver.
To change the ring speed:
1. Turn off the TRXI.
2. Place a small screwdriver through the TRXI’s air vent to access the
Ring Speed Switch.
3. Use the screwdriver to slide the switch to the desired setting as
shown in Figure 3-6.
4. Turn on the TRXI.
5. Check that the Ring Speed LED indicates the correct setting.
RING SPEED SWITCH SETTINGS
4 Mbps
16 Mbps
TRXI-24A TOKEN RING HUB WITH LANVIEW®
Ring Speed LED Indicator
On = 16 Mbps
Off = 4 Mbps
Figure 3-6. The Ring Speed Switch
Page 3-6
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
3.5 SETTING THE NVRAM SWITCH
Figure 3-7 shows the location of the NVRAM Reset Switch. The TRXI
uses NVRAM (Non-Volatile Random Access Memory) to store user
entered parameters such as IP address and device name. The NVRAM
Reset Switch restores these parameters to the factory defaults.
You do not have to remove the chassis cover to access the NVRAM
switch.
NVRAM RESET
SWITCH
TRXI-24A TOKEN RING HUB WITH LANVIEW®
Figure 3-7. NVRAM Reset Switch
To restore TRXI parameters to the factory defaults:
1. Change the state of this switch (i.e., move the switch from one
position to another).
2. Press the TRXI’s Reset button.
You can now use the factory default settings or re-enter your own
parameters. The TRXI stores these parameters in NVRAM during
normal operation and during power down, and they remain there until
you change the switch again.
Ca u tion : Do not change the state of the NVRAM switch unless you
intend to reset the TRXI user parameters to the factory default settings.
Page 3-7
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
3.6 CONNECTING THE TRXI TO THE P OWER SOURCE
Note: The TRXI has a universal power supply. This allows you to
connect the TRXI to power sources from 85 Vac to 264 Vac, 47-63 Hz.
To connect the TRXI to the power source, plug the power cord into a
grounded wall outlet. Turn on the power switch at the back panel of
the TRXI. Verify that the P WR LED is lit, indicating that the TRXI is
receiving power. After the TRXI runs a self test, the CP U LED blinks
green indicating normal operation. If the LED remains red, the
processor is faulty.
3.7 CONNECTING THE NETWORK LOBE P ORT CABLING
The TRXI-22A/24A network lobe ports consist of unshielded RJ 45
connectors that support UTP cabling. To connect a UTP segment from
the TRXI to a station supporting STP cabling, you need a Type 3
Media Filter available from Cabletron Systems (TRMF, TRMF-2).
The TRXI-42A/44A network lobe ports consist of shielded RJ 45
connectors that support STP cabling. Shielded patch cables that adapt
a shielded RJ 45 to a data connector (MIC) are available from
Cabletron Systems (PN 9372057-8). These adapter/patch cables let
you connect to an existing patch panel equipped with data connectors.
Figure 3-8 shows the TRXI’s network lobe port pinouts.
Device
Port
TRXI-22A/24A
TCU Port
RX-
TX+
3
4
3
4
TX-
RX+
RJ45 to RJ45
TX-
5
5
6
RX-
TX+
RX+ 6
TRXI-42A/44A
TCU Port
Data Connector
(MIC)
RX-
TX+
3
4
Green TX-
Orange RX+
Patch Panel/
Token Ring Station
RJ45 to MIC
TX-
5
Black RX-
RX+ 6
Red
TX+
Shield
Figure 3-8. Network Lobe Port Pinouts
Page 3-8
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
Figure 3-9 illustrates possible configurations for both the TRXI-24A
and TRXI-44A.
WALL
Punchdown
TRXI-24A
Block
TRXI-24
TOKEN RING HUB WITH
LANVIEW®
RO
RI
Token Ring
Network Interface Card
Token Ring
Station
UTP
Lobe Cable
TRMF
Wall
Jack
STP to UTP
Type 3 Media Filter
OFFICE
WIRING CLOSET
WALL
TRXI-44A
TRXI-24
TOKEN RING HUB WITH
LANVIEW®
RO
MIC Data
Connector
RI
Token Ring
Network Interface Card
Token Ring
Station
Patch
Panel
Wall
Jack
STP
Lobe Cable
OFFICE
WIRING CLOSET
Figure 3-9. Configuration Examples for TRXI-24A and TRXI-44A
Page 3-9
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
To attach a UTP or STP lobe segment to a TRXI network port:
1. Insert the RJ 45 connector from each twisted pair segment into the
desired RJ 45 network lobe port number on the TRXI as shown in
Figure 3-10.
RO
LNK
TPIM-T4
13
14
15
16
LNK
17
18
TPIM-T4
1
2
3
4
RI
5
6
Figure 3-10. TRXI Network Ports
2. The associated Port Status LED will light green when the station
boots up. If the LED is not lit, perform each of the following steps
until it is:
a. Check that the device at the other end of the twisted pair
segment is on and the network interface driver is initialized.
b. Verify that the RJ 45 connector on the twisted pair segment has
the proper pinouts.
c. Check the cable for continuity.
d. Check that the twisted pair connection meets dB loss and cable
specifications outlined in Chapter 2.
e. Check Local Management to ensure the port is enabled.
If a link still has not been established, contact Cabletron Systems
Technical Support.
Page 3-10
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
3.8 INSTALLING THE TP IM RI/RO MODULES
TPIMs provide RI/RO trunk port connections that support various
media for trunk cabling. You can attach different media types at the
Ring-In port and Ring-Out port. For example, you can insert a
TPIM-T1 as the Ring-In port and a TPIM-T4 as the Ring-Out port.
The following sections explain how to set the Phantom Switch, set the
RI/RO Switch, install the TPIM to the TRXI, and attach segments to
the TPIM.
Prior to connecting trunk cabling to the TPIMs, check the connectors
for proper pinouts. Table 3-1 provides a cross-reference of pinouts for
TPIMs used for Ring-In or Ring-Out applications.
Table 3-1. Pinout Cross-Reference for TPIMs
Signal TPIM-T2/T4
(RJ 45)
TPIM-T2/T4
(RJ 45)
TPIM-T1
(DB9)
TPIM-T1
(DB9)
Ring-In
Ring-Out
Ring-In
Ring-Out
TX+
TX-
RX+
RX-
6
3
4
5
4
5
6
3
9
5
1
6
1
6
9
5
Page 3-11
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
3.8.1 Settin g th e TP IM’s P h a n tom Sw itch a n d RI/RO Sw itch
Before you install a TPIM, set the Phantom Switch to the appropriate
setting. This switch enables the port to “autowrap” if a trunk cable
fails or is removed. Figure 3-11 shows the location of the Phantom
Switch. If you attach a Cabletron hub to the TPIM, leave the switch at
the factory default setting of 1. If you attach a Non-Cabletron device to
the TPIM, use the 0 setting.
Ensure that the Ring-In/Ring-Out Switch is in the factory default
RI/RO position. The TRXI does not support the Station (S) setting at
this time.
Note: If the switch locations on your TPIM do not match the locations
illustrated in Figure 3-11, refer to the TPIM Reference Card included
with the TPIM. The TPIM Reference Card outlines the current switch
locations and settings. If you have any questions, call Cabletron
Systems Technical Support.
Top View
8
0
2
.
5
P
H
A
C
N
T
(See Below For Settings)
O
M
S
T
N
RI/RO
S
RI/RO
TPIM-T1/TPIM-T2/TPIM-T4
TPIM-F2/TPIM-F3
Phantom Switch Settings
1 = Cabletron Device (Default)
0 = Non-Cabletron Device
Phantom Switch Settings
C = Cabletron Device (Default)
802.5 = Not Functional
RI/RO Switch Settings
RI/RO = Ring In/Ring Out (Default)
S = Station (Not Functional)
RI/RO Switch Settings
RI/RO = Ring In Ring Out (Default)
STN = Station (Not Functional)
Figure 3-11. The Phantom and RI/RO Switches
Page 3-12
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
3.8.2 In sta llin g a TP IM to th e TRXI
To install a TPIM, perform the following steps:
Ca u tion : Observe all static precautions while handling TPIMs.
1. Remove the mounting screw from the faceplate of the RI/RO port
on the TRXI.
2. If you are replacing a TPIM, remove the mounting screw and pull
the TPIM straight out from the TRXI.
3. Slide the new TPIM into place as shown in Figure 3-12.
4. Ensure the connectors on the rear of the module and on the inside
of the TRXI mate properly.
5. Reinstall the mounting screw.
RO
13
14
15
16
4
LNK
17
5
18
6
TPIM-T1
1
2
3
RI
LNK
TPIM-T1
Figure 3-12. Installing a TPIM
Page 3-13
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
3.8.3 Con n ectin g a Tw isted Pa ir Segm en t to th e TP IM-T1
Before connecting a segment to the TPIM-T1, check each end of the
segment to determine if the wires have been pinned properly.
To connect a TPIM-T1 to a Twisted Pair Segment:
1. Insert the DB9 connector on the segment into the DB9 port on the
TPIM as shown in Figure 3-13.
RO
LNK
TPIM-T1
13
14
15
16
4
LNK
17
5
18
6
TPIM-T1
1
2
3
RI
Figure 3-13. The TPIM-T1
2. Check that the LNK LED on the TPIM lights green. If the LED
lights red or is not lit, perform each of the following steps until it is:
a. Check that the device at the other end of the segment is on.
b. Verify that the DB9 is pinned properly.
c. Check the cable for continuity.
d. Check that the twisted pair connection meets dB loss and cable
specifications outlined in Chapter 2.
e. Check that the port is enabled through the Local Management.
If a link still has not been established, contact Cabletron Systems
Technical Support.
Page 3-14
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
3.8.4 Con n ectin g a Tw isted Pa ir Segm en t to th e TP IM-T2 or
TP IM-T4
The TPIM-T2 supports UTP cabling and the TPIM-T4 supports STP
cabling. The method for connecting an RJ 45 connector to an RJ 45 port
is the same for both UTP and STP cabling. Before connecting a
segment to the TPIM-T2 /T4, check each end of the segment to ensure
the wires are pinned properly. To connect a segment to a TPIM-T2/T4:
1. Insert the RJ 45 connector on the twisted pair segment into the
RJ 45 port on the TPIM as shown in Figure 3-14.
RO
LNK
TPIM-T2
13
14
15
16
LNK
17
18
TPIM-T2
1
2
3
4
RI
5
6
Figure 3-14. The TPIM-T2/T4
2. Check that the LNK LED on the TPIM lights green. If the LED
lights red or is not lit, perform each of the following steps until it is:
a. Check that the device at the other end of the segment is on.
b. Verify that the RJ 45 is pinned properly.
c. Check the cable for continuity.
d. Check that the twisted pair connection meets dB loss and cable
specifications outlined in Chapter 2.
e. Check that the port is enabled through Local Management.
If a link still has not been established, contact Cabletron Systems
Technical Support.
Page 3-15
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
3.8.5 Con n ectin g a Fiber Op tic Lin k Segm en t to th e TP IM-F 2
or TP IM-F 3
When connecting a fiber optic link segment to the TPIM-F2 or
TPIM-F3 keep the following in mind:
•
If you are connecting a fiber optic link segment with ST
connectors to a TPIM-F2 with ST ports, keep in mind that ST
connectors attach to ST ports much like BNC connectors attach
to BNC ports. The connector is inserted into the port with the
alignment key on the connector inserted into the alignment slot
on the port. The connector is then turned to lock it down.
•
The physical communication link consists of two strands of
fiber optic cabling: the Transmit (TX) and the Receive (RX). The
Transmit strand from the applicable port on the module will be
connected to the Receive port of a fiber optic device at the other
end of the segment. For example, TX of the applicable port on
the module will go to RX of the other fiber optic device. The
Receive strand of the applicable port on the module will be
connected to the Transmit port of the fiber optic device. For
example, RX of the applicable port on the module will go to TX
of the other fiber optic device.
It is recommended that you label the fiber optic cable to
indicate which fiber is Receive and which is Transmit. When
you buy fiber optic cable from Cabletron Systems, it is labeled
so that: at one end of the cable, one fiber is labeled 1, and the
other fiber is labeled 2. This pattern is repeated at the other
end of the cable. If you did not purchase your cable from
Cabletron Systems, be sure you have labeled your cable in the
manner described above.
Ca u tion : Do not touch the ends of the fiber optic strands, and do not let
the ends come in contact with dust, dirt, or other contaminants.
Contamination of the ends can cause problems in data transmissions. If
the ends become contaminated, clean them with alcohol using a soft,
clean, lint free cloth.
Page 3-16
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
To connect a fiber optic link segment to the TPIM-F2 or TPIM-F3:
1. Remove the protective plastic covers from the fiber optic ports on
the applicable port on the module and from the ends of the
connectors on each fiber strand.
2. Attach the fiber labeled 1 to the applicable receive port, labeled RX,
on the module as shown in Figure 3-15.
RO
TX
LNK
RX
TPIM-F2
13
1
TX
14
2
15
3
RX
16
4
LNK
17
5
18
6
TPIM-F2
RI
Figure 3-15. The TPIM-F2/F3
3. Attach the fiber labeled 2 to the applicable transmit port labeled
TX, on the module.
4. At the other end of the fiber optic cable, attach the fiber labeled 1
to the transmit port of the device.
5. Attach the fiber labeled 2 to the receive port.
6. Check that the LNK LED on the TPIM lights green. If the LED
does not light, perform each of the following steps until it is:
a. Check that the power is turned on for the device at the other
end of the link.
b. Verify that the fiber strands are properly “crossed-over”
between the applicable port on the module and the fiber optic
device at the other end of the fiber optic link segment.
Page 3-17
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
c. Verify that the fiber connection meets the dB loss specifications
outlined in Fiber Optic Network Requirements.
d. Check that the port is enabled through TRXI Local
Management.
If a link still has not been established, contact Cabletron Systems
Technical Support.
3.9 F INISHING THE INSTALLATION
The TRXI is now ready for operation. Before placing the network into
service, test the installation thoroughly, making sure that all stations
are able to be addressed and that the TRXI and all stations are
indicating normal operation. Ensure that the networking software is
configured properly to match the installed network. If you encounter
errors or abnormal operation, proceed to Chapter 4, Testin g a n d
Tr ou blesh ootin g.
Page 3-18
Download from Www.Somanuals.com. All Manuals Search And Download.
TESTING AND TROUBLESHOOTING
CHAP TER 4
TESTING AND TROUBLESHOOTING
This chapter contains procedures for testing the TRXI after you
connect it to the network. It also describes LANVIEW and explains
how to use the LCD to troubleshoot physical layer network problems.
4.1 CHECKING THE INSTALLATION
Perform the following to check the installation of the TRXI:
1. Trace the ring path through the network to be sure that there are
no breaks in the ring and that it is free from logical design errors.
a. Check each cable connection.
b. Verify the pinouts for every connection.
c. Check the cable conductors for continuity. Cable testers are
available for this task.
d. Check that cable connections at patch panels and wall plates
are secure.
2. Check the network ring speed:
a. Check the Ring Speed LED. Ensure the ring speed matches the
station and cable specifications mentioned in Chapter 2.
b. Be sure that all devices in the ring network are set to the same
ring speed. Check all stations in the network.
3. Ensure that the maximum cable length for EACH station and the
maximum number of stations are not exceeded.
When you complete each of these checks successfully, the TRXI is
ready for normal operation. If problems occur, contact Cabletron
Systems Technical Support.
Page 4-1
Download from Www.Somanuals.com. All Manuals Search And Download.
TESTING AND TROUBLESHOOTING
4.2 USING LANVIEW LEDs
LANVIEW is Cabletron Systems’ built-in visual diagnostic and status
monitoring system. Using LANVIEW, your network troubleshooting
personnel can quickly scan the LANVIEW LEDs to observe network
status or diagnose network problems, and determine which node or
segment is faulty. Figure 4-1 describes each of the front panel
LANVIEW LEDs.
TRXI-24A TOKEN RING HUB WITH LANVIEW®
24 23 22 21 20 19
18 17 16 15 14 13
24
12
23
11
12 11 10
9
8
7
1
RO
RI
PWR
CPU
ACT
MGMT
16 Mb/s
DISPLAY
RESET
6
5
4
3
2
COM 2 COM 1
DEFINITION
LED NAME
LED COLOR
Port Enable-No Link or Port Disable-No Link
Port Enable-Link
Port Disable-Link or Ring Speed Fault
Lobe Port Status
(Ports 1-24)
Off
Green (Solid)
Green (Blinking)
TPIM Inserted
TPIM Not Inserted
RI/RO
(Ring In/Ring Out)
Green (Solid)
Red (Solid)
No Power
Power
PWR
(Power)
Off
Green (Solid)
16 Mbps Ring Speed
4 Mbps Ring Speed
16 Mb/s
(Ring Speed)
Yellow (Solid)
Off
Good Frames
Beacon Frames
No Activity
ACT
(Network Activity)
Green (Flashing)
Red (Flashing)
Off
Management Agent Inserted
Management Agent Not Inserted
MGMT
Green (Solid)
(Network Management) Red (Solid)
CPU In Boot Process
CPU Initializing
CPU Functioning
CPU Not Functioning
CPU
Off
(Cental Processing Unit) Green (Flashing)
Green (Blinking)
Red (Solid)
Note: “Flashing” indicates an irregular LED pulse.
“Blinking” indicates a steady LED pulse.
Figure 4-1. LANVIEW LEDs
Page 4-2
Download from Www.Somanuals.com. All Manuals Search And Download.
TESTING AND TROUBLESHOOTING
4.3 USING THE LCD DISP LAY
The TRXI is equipped with an LCD as shown in Figure 4-2. The LCD
is a diagnostic tool that lets you view important status information
about the TRXI such as:
•
•
•
•
•
Power up diagnostics
Revision levels
Hardware MAC address
IP address
Error alerts.
The LCD presents four types of messages: Static System Messages,
Saved Alarm Messages, Unsaved Initialization Messages, and Saved
System Messages. The following sections describe each message.
LCD
TRXI-24A TOKEN RING HUB WITH LANVIEW®
24 23 22 21 20 19
18 17 16 15 14 13
24
12
23
11
12 11 10
9
8
7
1
RO
RI
PWR
CPU
ACT
MGMT
16 Mb/s
DISPLAY
RESET
6
5
4
3
2
COM 2 COM 1
Figure 4-2. LCD Display
Page 4-3
Download from Www.Somanuals.com. All Manuals Search And Download.
TESTING AND TROUBLESHOOTING
4.3.1 Sta tic System Messa ges
These messages display TRXI configuration information. To view the
Static System Messages, momentarily press the Display button
located below the LCD window. Press the Display button to scroll
through each message. If you do not press the Display button within
ten seconds, the display defaults back to the product name.
Disp la yed Messa ge
Com m en ts
IP Address
Displays the current IP
xxx.xxx.xxx.xxx
address. This may be changed
through Local Management.
MAC Address
0000B8xxxxxx
Displays the Hardware
or MAC address.
RAM Image
Rev. xx.xx.xx
Displays the revision number of the
Flash EEPROM.
Boot PROM
Rev. xx.xx.xx
Displays the revision number of the
internal Boot PROM.
Flash Programmed
xx Times
Displays the number of times the
the Flash EEPROM has been
programmed
COM 1
Baud Rate xxxxxx
Displays the current baud rate
of the COM 1 port.
COM 1
Function xxxxxx
Displays the current function
(Console, Modem, UPS, or SLIP) of
the COM 1 port.
COM 2
Displays the current
Baud Rate xxxxxx
baud rate of the COM 2 port.
COM 2
Function xxxxxx
Display the current function
(-N/A-,Console, Modem, UPS, or
SLIP) of the COM 2 port.
Page 4-4
Download from Www.Somanuals.com. All Manuals Search And Download.
TESTING AND TROUBLESHOOTING
4.3.2 Ala r m Messa ges
Alarm messages pertain to events that occur within the TRXI. Press
the Display button and hold for five seconds to access the Alarm
Messages queue. You can scroll through each message by pressing the
Display button. If you do not press the Display button for ten seconds,
the LCD defaults to the product name.
Disp la yed Messa ges
Com m en ts
No Messages in
Queue
No alarm messages in queue. This is
the Alarm Messages default setting.
Port xxxxxx
Disabled
Network port or TPIM turned off
via Local or Remote Management.
Port xxxxxx
Enabled
Network port or TPIM turned on
via Local or Remote Management.
Port xx Violation
Ring Beaconing
Indicates unauthorized access
attempt at network lobe ports.
Indicates a station is attempting to
recover from a hardware problem on
the ring.
Beacon Recovered
Indicates the ring has recovered
from a beaconing situation.
Beacon Recv
Port xx Removed
Indicates that a station has been
removed from the ring as a result of
the beacon recovery process.
Ring Port xx Faulted
Indicates a TPIM RI or RO has
Autowrapped.
Fault Recovery Oscillation
Indicates that the network has been
in and out of a beaconing state
several times.
Page 4-5
Download from Www.Somanuals.com. All Manuals Search And Download.
TESTING AND TROUBLESHOOTING
4.3.3 Un sa ved In itia liza tion Messa ges
These are power-up messages that appear on the LCD as the event
occurs but are not saved in a buffer for future recall. If Fa ilu r e or
Er r or Messa ges appear, call Cabletron Technical Support.
Fa ilu r e or Er r or Messa ges
Cabletron
Cabletron
Ctrl. Reg. Err.
BBRAM Failure
Cabletron
Cabletron
SDRAM Failure
Modem SCC Error
Cabletron
Cabletron
Bit Swap Failure
Console SCC Error
Cabletron
Cabletron
LDRAM Failure
82C54 Failure
Cabletron
Eagle Failure
Nor m a l Un sa ved In itia liza tion Messa ges
Cabletron
Hardware Init
Cabletron
Boot From Flash
Cabletron
Eagle Test
Cabletron
Cabletron
Cabletron
BOOTP Discovery
RARP Req. State
Bit Swap Test
Cabletron
Cabletron
TFTP Req. State
TFTP in Progress
Cabletron
Cabletron
TFTP Complete
Erasing Flash
Cabletron
Cabletron
Writing Flash
Flash Programmed
Cabletron
Cabletron
Test in Progress
Programming LRAM
Cabletron
Cabletron
Boot Complete
TRXI-xx Cabletron
Page 4-6
Download from Www.Somanuals.com. All Manuals Search And Download.
TESTING AND TROUBLESHOOTING
4.3.4 Sa ved System Messa ges
Saved System Message are device related start-up or boot strap
messages, BOOTP/TFTP host, or start-up error messages. To access
the Saved System Messages queue, you must first enter the Saved
Alarm Messages queue. While in the Alarm Messages queue, press the
Display button and hold for five seconds. You can scroll through each
message by pressing the Display button. If you do not press the
Display button for ten seconds, the LCD defaults to the product name.
Disp la yed Messa ge
TFTP Host
TFTP File
xxx.xxx.xxx.xxx
xxxxxxxxxxxxxxxx
Last TFTP Host
xxx.xxx.xxx.xxx
Last TFTP File
xxxxxxxxxxxxxxxx
BootP Host
xxx.xxx.xxx.xxx
Page 4-7
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
CHAP TER 5
LOCAL MANAGEMENT
This chapter explains how to set up a management terminal to access
the TRXI’s Local Management. It also explains the Local Management
screens and instructions for using them.
Local Management provides the tools to manage the TRXI and all of
its attached segments. You can change factory defaults, enable/disable
ports, and use the advanced features of Local Management to:
•
control access to your token ring network using the Ring
Security feature
•
•
assign an IP address and subnet mask
set interface parameters for both serial ports, Local
Management (Console), Serial Line Internet Protocol (SLIP),
Uninterruptible Power Supply proxy (UPS), or Modem
•
•
•
control password access to the TRXI through the community
names established in the Community Names Table
designate which Network Management Workstations receive
trap alarms from the device
navigate through the Management Information Base (MIB)
and manage the objects within it from a remote location. Given
the appropriate security level, the MIB is accessible from the
TRXI through the SNMP Tools screen.
Page 5-1
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
5.1 MANAGEMENT TERMINAL REQUIREMENTS
To access TRXI Local Management, you need either:
•
•
a Digital Equipment Corporation VT series terminal
a VT type terminal running emulation programs for the Digital
Equipment Corporation VT series
•
an IBM or compatible PC running a VT series emulation
software package.
5.1.1 Atta ch in g th e Ma n a gem en t Ter m in a l
Cabletron supplies an RJ 45 Cable Kit with the TRXI. This kit includes
a UTP console cable with RJ 45 connectors on each end. It also
provides adapters for DB9 or DB25 connections. Refer to the RJ 45
Cable Kit Instruction Sheet for adapter pinouts and additional
instructions.
To attach the management terminal to the TRXI’s COM 1 port:
1. Attach the male RJ 45 connector to the COM 1 port of the TRXI as
shown in Figure 5-1.
2. Attach the female end (25-pin or 9-pin, as applicable) to the COM
port on the terminal.
COM PORT
COM 1 RJ45 PORT
TRXI-24A TOKEN RING HUB WITH LANVIEW®
CONSOLE CABLE
MANAGEMENT TERMINAL
Figure 5-1. Management Terminal Connection
Page 5-2
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
5.1.2 Settin g th e Ma n a gem en t Ter m in a l Setu p Pa r a m eter s
Table 5-1 lists the setup parameters for the local management
terminal. If you have a Digital Equipment Corporation VT terminal,
press F 3 to access the Setup Directory. If you have a PC emulation of
the Digital Equipment VT terminal, refer to your equipment user
manual for setup parameters.
Table 5-1. VT Terminal Setup Parameters
MENU
FUNCTION
Columns
SELECTION
80 Columns
Disp la y Setu p :
Controls
Interpret Controls
No Auto Wrap
Cursor
Auto Wrap
Test Cursor
Mode
Gen er a l Setu p :
7 Bit Control
Cursor Keys
Normal Cursor Keys
Transmit = 9600
Com m u n ica tion s Transmit
Setu p :
Receive
XOFF
Receive = Transmit
any option
Bits, Parity
Stop Bit
Local Echo
Port
8 Bits, No Parity
1 Stop Bit
No Local Echo
DEC-423, Data
Leads Only
Transmit
any option
Auto Answerback
No Auto Answerback
any option
Keyboa r d Setu p : Auto Repeat
Keyclick
any option
Margin Bell
Margin Bell
Warning Bell
Warning Bell
No Auto Answerback
Auto Answerback
Page 5-3
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
5.1.3 Mod em Ca ble Con figu r a tion a n d Setu p
To access Local Management from a modem, use an RS-232 cable
available from Cabletron Systems. This cable connects the modem to
the TRXI COM 2 port. Figure 5-2 shows the pinout for a cable with an
RJ 45 connector at the TRXI end of the cable.
RJ45 COM 2 PORT
RJ45 COM 2
Port
25-Pin Female
"D" Shell Connector
1
4
3
7
8
RECEIVE
RECEIVE
SIGNAL GROUND
SIGNAL GROUND
DATA CARRIER DETECT
DATA TERMINAL READY
RING
5
2
8
2
RING
Figure 5-2. Modem Cable Pinouts
To access Local Management, proceed as follows:
1. Turn the modem on. The modem must be set for Auto Answer and
Data Carrier Detect must be active. Refer to your modem’s user
manual for operating instructions.
2. Call the modem. The TRXI Password screen appears when you
establish a connection.
Page 5-4
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
5.2 ACCESSING LOCAL MANAGEMENT
With your terminal properly configured and the correct physical cable
connections in place, you can access Local Management.
To access Local Management:
1. Turn the terminal on. The TRXI Password screen shown in
Figure 5-3 appears.
TRXI LOCAL MANAGEMENT
Cabletron Systems Incorporated
P.O. Box 5005
Rochester, NH 03867-0505
(603) 332-9400
(c) Copyright Cabletron Systems, Inc. 1994
Flash Image Version:
Boot EPROM Version:
Board Revision:
X.XX.XX
XX.XX.XX
X
Enter User Password:
Figure 5-3. TRXI Password Screen
2. Enter your P a ssw or d . (The factory default password is the
Retu r n key.)
Note: Your password is one of the community names specified in the
Community Name Table. Access to certain Local Management
capabilities depends on the degree of access accorded that community
name. See Section 5.3.2 for more information about community names.
3. If your password is valid, the Main Menu screen shown in
Figure 5-4 appears. If your password is not valid, the cursor
returns to the beginning of the password field.
Page 5-5
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
5.3 USING LOCAL MANAGEMENT
TRXI Local Management consists of three menu screens:
•
•
•
the Main Menu screen
the Device Setup screen
and the Device Status screen.
Menu screens list TRXI Local Management options. Figure 5-4 shows
the menu screens and each Local Management option. The following
sections explain how to select and use each of the Local Management
options.
Flash Image Version: X.XX.XX
MAIN MENU
TRXI LOCAL MANAGEMENT
DEVICE SETUP
DEVICE STATUS
DEVICE STATISTICS
MIB NAVIGATOR
SNMP TOOL
EXIT LM
Flash Image Version: X.XX.XX
Flash Image Version: X.XX.XX
TRXI LOCAL MANAGEMENT
TRXI LOCAL MANAGEMENT
DEVICE SETUP
DEVICE STATUS
CHASSIS STATUS VIEW
COMPONENT STATUS VIEW
RMON VIEW
SYSTEM LEVEL
SNMP COMMUNITY NAMES
SNMP TRAPS
RING SECURITY
FLASH DOWNLOAD
RETURN
RETURN
Figure 5-4. Local Management Menu Screen
Page 5-6
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
Selectin g a Men u Op tion
To select a menu option:
1. Use the arrow keys to highlight a menu option.
2. Press Retu r n . The selected screen appears.
Exitin g a Loca l Ma n a gem en t Scr een
To exit a Local Management screen:
1. Use the arrow keys to highlight the RETURN command at the
bottom of the screen.
2. Press Retu r n . Local Management returns to the associated Menu
screen.
Exitin g You r Loca l Ma n a gem en t Session
To exit your Local Management session:
1. Use the arrow keys to highlight the RETURN command at the
bottom of the screen.
2. Repeat Step 1 until you arrive at the Main Menu screen.
3. Use the arrow keys to highlight the EXIT LM command at the
bottom of the Main Menu screen.
4. Press Retu r n . The Password screen appears.
Page 5-7
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
5.3.1 Th e System Level Scr een
The System Level screen lets you view TRXI information such as COM
port status and MAC address. You can also use the System Level
screen to set the IP Address, Subnet Mask, and System Date/System
Time. Figure 5-5 shows the System Level screen.
Flash Image Version: X.XX.XX
TRXI LOCAL MANAGEMENT
SYSTEM LEVEL
System Time: 14:00:00
Subnet Mask
000.000.000.000 000.000.000.000
System Date: 06/26/94
IPAddress
SNMPAgent
COM 1
COM 2
[ CONSOLE ]
N/A
[
]
Clear SNMPAgent IPAddress and Community Names Only:
Clear All NVRAM: [NO]
[NO]
Enable Beacon Recovery:
[NO]
MAC Address
00-00-B8-00-00-00
Physical:
SAVE
RETURN
Figure 5-5. System Level Screen
The following sections provide a brief explanation of each field on the
System Level screen and instructions for using them.
System Da te
Displays the current date.
System Tim e
Displays the current time.
IP Ad d r ess
Displays the IP Address of the SNMP agent.
Su bn et Ma sk
Displays the Subnet Mask of the SNMP agent.
Page 5-8
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
COM 1 Ap p lica tion
Displays the port’s application as either Console, SLIP, UPS, or
Modem.
COM 2 Ap p lica tion
Displays the port’s application as either Console, SLIP, UPS, Modem,
or N/A.
Clea r All NVRAM
Clears all battery backed up memory.
Clea r SNMP a gen t IP Ad d r ess a n d Com m u n ity Na m es On ly
Clears battery backed up memory of IP Address and Community
Names.
En a ble Bea con Recover y
Enables Beacon Recovery.
MAC Ad d r ess
Displays the physical hardware address.
Settin g th e System Da te
To set the System date:
1. Use the arrow keys to highlight the System Da te field.
2. Enter the date into the field in a MM/DD/YY format.
3. Press Retu r n . If the format not valid, the message “INVALID
DATE” appears. Re-enter the date using the correct format.
4. If the format is correct, use the arrow keys to highlight the SAVE
command at the bottom of the screen.
5. Press Retu r n . The “SAVED” message appears on the screen
indicating that your changes have been saved to memory.
Page 5-9
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
Settin g th e System Tim e
To set the system time:
1. Use the arrow keys to highlight the System Tim e field.
2. Enter the time into the field in a HH:MM:SS format.
3. Press Retu r n . If the format is not valid, the message “INVALID
TIME” appears. Re-enter the time using the correct format.
4. If the format is correct, use the arrow keys to highlight the SAVE
command at the bottom of the screen.
5. Press Retu r n . The “SAVED” message appears on the screen
indicating that your changes have been saved to memory.
Settin g th e IP Ad d r ess
To set the IP Address:
1. Use the arrow keys to highlight the IP Ad d r ess field.
2. Enter the IP Address into the field. The format for this entry is
XXX.XXX.XXX.XXX, with values of XXX ranging from 0-255.
3. Press Retu r n . If the format is not valid, the message “INVALID IP
FORMAT” appears. Re-enter the IP Address using the correct
format.
4. If the IP Address is correct, use the arrow keys to highlight the
SAVE command at the bottom of the screen.
5. Press Retu r n . The “SAVED” message appears on the screen
indicating that your changes have been saved to memory.
Page 5-10
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
Settin g th e Su bn et Ma sk
Note: Consult your Network Administrator prior to setting the Subnet
Mask.
The Subnet Mask defines how your TRXI treats SNMP Trap IP
destination addresses in its Community Names table.
•
Set the Subnet Mask when workstations in the Community
Names table reside on a different subnet (i.e., across a gateway
or router), and you want these workstations to receive traps.
•
Use the Subnet Mask factory default setting of 0.0.0.0 when all
trap designated workstations are on the TRXI subnet.
To set the Subnet Mask:
1. Use the arrow keys to highlight the Su bn et Ma sk field.
2. Press Retu r n to clear the field.
3. Enter the Subnet Mask into the field. The format for this entry is
XXX.XXX.XXX.XXX, with values of XXX ranging from 0-255.
4. Press Retu r n . If the format is not valid, the “INVALID IP
FORMAT” message appears. Re-enter the Subnet Mask using the
correct format.
5. If the format is correct, use the arrow keys to highlight the SAVE
command at the bottom of the screen.
6. Press Retu r n . The “SAVED” message appears on the screen
indicating that your changes have been saved to memory.
Settin g th e Clea r SNMP Agen t IP Ad d r ess a n d Com m u n ity
Na m es On ly F ield
To set this field:
1. Use the arrow keys to highlight the Clear SNMP Agent IP Address
and Community Names Only field.
2. Press Retu r n to toggle from Yes to No.
Page 5-11
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
3. Select Yes to Clear SNMP Agent IP Address and Community
Names Only or No to escape the field.
4. Use the arrow keys to highlight the SAVE command.
5. Press Retu r n . The “SAVED” message appears on the screen
indicating that your changes have been saved to memory.
Settin g th e Clea r All NVRAM F ield
To set the Clear All NVRAM field:
1. Use the arrow keys to highlight the Clea r All NVRAM field.
2. Press Retu r n to toggle from Yes to No.
3. Select Yes to clear NVRAM or No to escape the field.
4. Use the arrow keys to highlight the SAVE command.
5. Press Retu r n . The “SAVED” message appears on the screen
indicating that your changes have been saved to memory.
Settin g th e En a ble Bea con Recover y F ield
To set the Enable Beacon Recovery field:
1. Use the arrow keys to highlight the Enable Beacon Recovery field.
2. Press Retu r n to toggle from Yes to No.
3. Select Yes to enable Beacon Recovery or No to escape the field.
4. Use the arrow keys to highlight the SAVE command.
5. Press Retu r n . The “SAVED” message appears on the screen
indicating that your changes have been saved to memory.
Page 5-12
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
5.3.2 Th e SNMP Com m u n ity Na m es Scr een
The SNMP Community Names screen lets you set community names.
Community names serve two purposes; they act as passwords to Local
Management and they are agents of security control to your TRXI. You
control TRXI access by establishing up to three levels of security
authorization (Read Only, Read-Write, and Super-User). Only a user
with Super-User access can change the device IP address and the
community names.
Ca u tion : Community Names are passwords to Local Management.
Remember your Community Name.
Local Management passwords accorded Read-Only and Read-Write
access privileges are not allowed editing capabilities to some fields. In
this case, the message “AUTHORIZATION PROHIBITS ACCESS”
appears. Figure 5-6 shows the SNMP Community Names screen.
Flash Image Version: X.XX.XX
TRXI LOCAL MANAGEMENT
Component Name
SNMP COMMUNITY NAMES
Community Name
Access Policy
TRXI Chassis MGR
TRXI Chassis MGR
TRXI Chassis MGR
public
ring1
READ-ONLY
READ-WRITE
SUPER-USER
<CR>
SAVE
RETURN
Figure 5-6. SNMP Community Names Screen
Page 5-13
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
The following sections provide a brief explanation of each field on the
SNMP Community Names screen and instructions for using them.
Com p on en t Na m e
Displays the component name as TRXI Chassis Manager.
Com m u n ity Na m e
Displays the Community Name or “password” to Local Management.
Access
Displays the access level accorded to each community name. The
following list defines each access code:
Read-Only
This allows read-only access to Local Management,
but excludes access to security protected fields of the
upper levels of authorization (Read-Write or
Super-User).
Read-Write
Super-User
This allows you to read and write to Local
Management fields, excluding IP Address, Subnet
Mask, and Community Names and Ring Security.
This allows read-write access to all modifiable
parameters including Community Names, IP
Addresses, Traps, Ring Security, and SNMP objects.
Ed itin g th e Com m u n ity Na m e F ield
To edit the Community Name field:
1. Use the arrow keys to highlight the Com m u n ity Na m e field.
2. Enter the password, up to 26 characters in length, into the field. If
you press Retu r n without entering a password, the field defaults
to Public.
3. Use the arrow keys to highlight the SAVE command at the bottom
of the screen.
4. Press Retu r n . The “SAVED” message appears indicating that your
changes have been saved to memory.
Page 5-14
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
5.3.3 Th e SNMP Tr a p s Scr een
The SNMP Traps screen lets you designate which management
workstations receive trap messages. Figure 5-7 shows the SNMP
Traps screen.
Flash Image Version: X.XX.XX
TRXI LOCAL MANAGEMENT
Trap Destination
SNMP TRAPS
Trap Community Name
Enable Traps
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
<CR>
<CR>
<CR>
<CR>
<CR>
<CR>
<CR>
<CR>
N
N
N
N
N
N
N
N
SAVE
RETURN
Figure 5-7. SNMP Traps Screen
The following sections provide a brief explanation of each field on the
SNMP Traps screen and instructions for using them.
Tr a p Destin a tion
Indicates the IP Address of the workstation that will receive trap
alarms from the TRXI.
Tr a p Com m u n ity Na m e
Displays the user-defined name of the SNMP Compliant Network
Management Workstations to receive trap alarms from the TRXI.
En a ble Tr a p s
Enables the transmission of SNMP trap messages.
Page 5-15
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
Settin g SNMP Tr a p s
To set SNMP traps:
1. Use the arrow keys to highlight the Tr a p Destin a tion field.
2. Enter the IP address of the device that will receive trap alarms
from the TRXI, then press Retu r n . The format for this entry is
XXX.XXX.XXX.XXX, with the value of XXX ranging from 0 to 255.
3. Use the arrow keys to highlight the Tr a p Com m u n ity Na m e
field.
4. Enter the community name of the device, then press Retu r n . If you
press Retu r n without entering a community name, the field
defaults to <CR>.
5. Use the arrow keys to highlight the En a ble Tr a p s field.
6. Enter Y (yes) to send alarms from the TRXI to the workstation, or
N (no) to prevent alarms from being sent.
7. Use the arrow keys to highlight the SAVE command at the bottom
of the screen.
8. Press Retu r n . The “SAVED” message appears indicating that your
changes have been saved to memory.
Page 5-16
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
5.3.4 Th e Rin g Secu r ity Scr een
The Ring Security screen lets you control access to your token ring
network. Figure 5-8 shows the Ring Security screen. When you enable
ring security, the TRXI stores the MAC address of each station on the
token ring network in a secure database or “allowed list.” Only
stations on the allowed list can enter the ring. The TRXI can store up
to 250 station MAC addresses on the allowed list. The TRXI retains
the allowed list in its battery-backed Non-Volatile Random Access
Memory (NVRAM). If you power up or reset the TRXI, NVRAM
retains the allowed list and automatically re-enables ring security.
Flash Image Version: X.XX.XX
TRXI LOCAL MANAGEMENT
RING SECURITY
STATION ADDRESS
00-00-00-00-00-00
Stn Edit [00-00-00-00-00-00] [Add]
Security Mode [Disabled]
SAVE/EXECUTE NEXT_SCREEN PREVIOUS_SCREEN RETURN
Figure 5-8. Ring Security Screen
You can append the allowed list by temporarily disabling ring security,
then re-enabling it using the Alarms Only feature. The TRXI acts as
the Ring Security Monitor for the ring and provides security for the
entire ring.
Note: You should enable the Ring Security feature on only on e TRXI
per token ring.
You can select two modes of ring security; Alarm Only and
Alarm/Remove. In the Alarm Only mode, new stations can enter the
ring, but a “station added” trap/alarm notifies the Network
Management Station (NMS) of the event.
Page 5-17
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
The trap/alarm includes the new station’s MAC address so that you
can decide if the new station should be allowed to remain on the ring.
If you select the Alarm/Remove mode, ring security sends a “Remove
MAC Frame Command” to new stations attempting to enter the ring,
and a trap/alarm to the NMS informing it of the action taken. If the
Remove MAC Frame Command fails to remove the new station after
three attempts, ring security sends a trap/alarm to the NMS
informing it that “the station could not be removed.”
The following section provides a brief explanation of each field and
command on the Ring Security screen and instructions for using them.
Note: Before you begin, you must set up the TRXI’s SNMP Traps screen
to designate which Network Management Stations receive trap/ alarms
(refer to the SNMP Traps screen section). This ensures that trap/ alarms
generated by ring security arrive at the appropriate destination.
Sta tion Ad d r ess
This field lists the MAC address of each station on the ring security
allowed list. This field can lists up to 250 MAC addresses on 22 local
management screens.
Stn Ed it
The Station Edit command lets you add or delete stations from the
allowed list. Use the Stn Edit command for single entry edits to the
allowed list (refer to the Alarm Only security mode definition for
information about adding multiple users).
Secu r ity Mod e
This command lets you set the Security Mode for the ring. Security
Modes determine the level of ring security. You can select the following
Security Modes:
•
Disa bled - This is the factory default setting. Use this option
to temporarily disable ring security so that new stations can
enter the ring.
•
Ala r m On ly - In this mode, ring security allows new stations
to enter the ring. When a station enters the ring, ring security
sends a “station added” trap/alarm to the Network
Management Station.
Page 5-18
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
The “station added” trap message includes the new station’s
MAC address so that you can decide if the new station should
be allowed on the ring.
To add multiple users to the ring, temporarily disable ring
security using the Disable mode, then select the Alarm Only
mode to re-enable ring security. Ring Security stores the MAC
address of each station on the ring to the allowed list. This
saves you from entering MAC addresses one at time using the
Stn Edit command. Refer to “Building the Allowed List” for
instructions.
•
Ala r m /Rem ove - This is the highest level of ring security.
When in the Alarm/Remove mode, ring security sends a
“Remove MAC Frame Command” to new stations attempting to
enter the ring, and a trap/alarm to the NMS informing it of the
action taken. The “Remove MAC Frame Command” tries to
automatically remove the station from the ring. If it cannot
remove the station from the ring after three attempts, it sends
a trap/alarm to the NMS informing it that “the station could
not be removed.”
SAVE/EXECUTE
This command saves all security mode changes to the TRXI’s NVRAM.
You must use the SAVE/EXECUTE command for your changes to take
effect.
NEXT_SCREEN
Use this command to scroll to the next screen of the allowed database.
P REVIOUS_SCREEN
Use this command to scroll back to the previous screen of the allowed
database list.
RETURN
Use this command to exit the Ring Security screen and return to the
Device Setup screen.
Page 5-19
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
Bu ild in g th e Allow ed List
Note: You must set the Security Mode field to Disa bled before you build
the allowed list.
To build the allowed list:
1. Use the arrow keys to highlight the Security Mode field.
2. Press Retu r n to toggle selections (Disabled, Alarm Only, Remove/
Alarm). Select the Ala r m On ly option.
3. Use the arrow keys to highlight the SAVE/EXECUTE command.
4. Press Retu r n . The TRXI enables ring security and generates the
allowed list. The “SECURITY MODE CHANGED” message
appears at the top of the screen.
5. To view the allowed list, you must refresh the Ring Security screen
by exiting, then re-entering the screen.
Ad d in g Sta tion s to th e Sta tion Ad d r ess Allow ed List
To add stations one at a time to the Station Address allowed list:
1. Use the arrow keys to highlight the Stn Edit field.
2. Press Retu r n to clear the field.
3. Enter the MAC address of the station you want to add in
XX-XX-XX-XX-XX-XX format. To delete characters use the
Ba ck sp a ce key.
4. Use the arrow keys to highlight the Add/Del field.
5. Press Retu r n to toggle selections. Select the Ad d option.
6. Use the arrow keys to highlight the SAVE/EXECUTE command.
7. Press Retu r n . The station’s MAC address appears on the screen.
Page 5-20
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
Deletin g Sta tion s fr om th e Sta tion Ad d r ess Allow ed List
To delete stations from the Station Address allowed list:
1. Use the arrow keys to highlight the Stn Edit field.
2. Press Retu r n to clear the field.
3. Enter the MAC address of the station you want to delete in
XX-XX-XX-XX-XX-XX format. To delete characters, use the
Ba ck sp a ce key.
4. Use the arrow keys to highlight the Add/Del field.
5. Press Retu r n to toggle selections. Select the Del option.
6. Use the arrow keys to highlight the SAVE/EXECUTE command.
7. Press Retu r n . The station’s MAC address is deleted.
Note: You must set ring security to the Alarm/ Remove mode to
effectively delete a station from the allowed list and keep it off the ring.
If you delete a station from the allowed list while in the Alarm Only
mode, the station can re-enter the ring and its Mac address will
reappear in the allowed list.
Ch a n gin g th e Rin g Secu r ity Mod e
To change the Security Mode:
1. Use the arrow keys to highlight the Security Mode field.
2. Press Retu r n to toggle selections (Disabled, Alarm Only, Remove/
Alarm). Select the desired option.
3. Use the arrow keys to highlight the SAVE/EXECUTE command,
then Press Retu r n . The TRXI enables the selected mode of ring
security.
Page 5-21
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
5.3.5 Th e Device Sta tistics Scr een
The Device Statistics screen lets you view ring information, isolating
errors, and non-isolating errors. Figure 5-9 shows the Device Statistics
screen.
Flash Image Version: X.XX.XX
DEVICE STATISTICS (TOTAL)
TRXI LOCAL MANAGEMENT
INTERFACE:
1
RING INFORMATION
Frames Received: 0
KBytes Received: 0
Errors Received: 0
Active Monitor Addr: 00-00-00-00-00-00
Ring Status: Normal
Ring Number:
0
1
Beacon States: 0
Stations on Ring:
Ring Purges: 0
Active Monitor Changes: 0
Ports Enabled: 24
Ring Speed (Mb/s): 16
ISOLATING ERRORS
Line Errors: 0
NON-ISOLATING ERRORS
Lost Frame Errors: 0
Frame Copied Errors: 0
Rcvr Congestion Errors: 0
Token Errors: 0
Burst Errors: 0
AC Errors: 0
Abort Transmit Errors: 0
Internal Errors: 0
Frequency Errors: 0
ACCUMULATE DELTA
REFRESH99sec
RETURN
Figure 5-9. Device Statistics Screen
The following section provides a brief explanation of each field on the
Device Statistics screen and instructions for using them.
Device Sta tistics
Displays the Device Statistics counter mode. The counter mode lets
you determine how you want the Device Statistics screen to gather
statistics. You can choose the following methods:
•
•
•
Accumulate: Initiates a new statistic count.
Delta: Total of statistics beginning from the last screen refresh.
Total: Total of statistics beginning from the last power-up.
In ter fa ce
Displays the network interface. This field is always 1.
Page 5-22
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
F r a m es Received
Displays the total frames detected on the ring since the TRXI was last
powered on or reset.
KBytes Received
Displays the kilobyte sum of all frames detected on the TRXI since it
was last powered up or reset.
Er r or s Received
Displays the total Isolating and Non-Isolating Errors detected by the
TRXI.
Bea con Sta tes
Displays the total beacon states detected by the TRXI. Stations
transmit beacons when they detect bit streaming or signal loss on the
ring.
Rin g P u r ges
Displays the total ring purge frames transmitted by the active
monitor.
Active Mon itor Ch a n ges
Displays the number of times a different station has been active
monitor.
ISOLATING ERRORS
Isolating Errors are “soft” ring errors that report the domain of a fault
(that is, you can isolate the fault’s region to the transmitting adapter,
the receiving adapter, and the components - cabling and wiring
concentrators - between the two).
Lin e Er r or s
Displays the total line errors detected by the TRXI. Line Errors
are corrupted frames that are detected by a node. This type of
error normally occurs when stations enter and leave the ring.
This error can also indicate a problem with the receiver of the
reporting node, or the transmitter of its Nearest Active
Upstream Neighbor (NAUN), or the cabling and hub hardware
between them.
Page 5-23
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
Bu r st Er r or s
Displays the total burst errors detected by the TRXI. Burst
Errors are the absence of clocking signals at a node’s receiver.
This error normally occurs when stations enter or leave the ring
with the absence of phantom current.
This error can also indicate a problem with the receiver of the
reporting node, or the transmitter of its NAUN, or the cabling
and hub hardware between them.
AC Er r or s
Displays the total Address Recognized/Frame Copied errors.
This indicates that the reporting NAUN is faulty. The node
cannot set the address recognized indicator and/or frame copied
indicator bits in the frame which it has copied. This leaves the
downstream node with an incorrect NAUN address.
Abor t Tr a n sm it Er r or s
Displays the total abort delimiter frames transmitted by a
station. This indicates that either the reporting node has
detected an error on itself, or there is an error with its NAUN, or
the cabling and wiring hubs between them.
In ter n a l Er r or s
Displays the total internal errors detected by the adapter’s
hardware and/or firmware. These errors cause the adapter to
remove itself from the ring and indicates a problem with the
adapter hardware or firmware (possibly an inoperable chipset,
timers, or counters).
RING INF ORMATION
Ring Information provides ring status information.
Active Mon itor Ad d r
Displays the MAC address of the active monitor. The active
monitor initiates recovery procedures from various error
situations.
Rin g Sta tu s
This field lists the current status of the ring being monitored by
the TRXI. TRXI displays the following ring status conditions:
Page 5-24
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
•
•
Un k n ow n , Indicates the state of the ring cannot be
detected by the management station.
Closed , Indicates that the management station is not
inserted into the ring and therefore cannot determine the
ring state.
•
•
•
Nor m a l, Indicates the ring is running with no problems,
and tokens are being detected by the management
station.
P u r ge, Indicates that the active monitor has issued a
ring purge command. Communications will be restored
when a new token is released.
Con ten tion , Indicates that the ring has entered into the
active monitor contention process to determine a new
active monitor for the ring.
•
•
Bea con in g, Indicates that the management station has
detected a beacon frame.
Lobe Fa il, Indicates that a station failed the lobe self-
test when it attempted to insert into the ring.
Rin g Nu m ber
Displays the number of rings on the network.
Sta tion s on a Rin g
Displays the number of stations inserted into the ring.
P or ts En a bled
Displays the number of network lobe ports enabled.
Rin g Sp eed
Displays the ring speed of the TRXI as either 4 Mb/s or 16 Mb/s.
NON-ISOLATING ERRORS
Non-Isolating Errors are “soft error” conditions that could have been
caused by any station on the ring. Their fault domain cannot be
detected.
Lost F r a m e Er r or s
Displays the total number of Lost Frame Errors. These errors
occur when the adapter fails to receive the end of the frame it
has just transmitted. The frame was lost somewhere on the ring
but there is no way to pinpoint where. This can be caused by
stations entering or leaving the ring.
Page 5-25
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
F r a m e Cop ied Er r or s
Displays the total number of Frame Copied Errors. These errors
occur when a station finds a frame with its address as the
destination, but finds the address recognized indicator bits not
set to zero. This indicates a possible duplicate address.
Rcvr Con gestion Er r or s
Displays the total number of Rcvr Congestion Errors. This
indicates a station is receiving/repeating a frame and recognizes
a frame addressed to it, but has no buffer space available for the
frame.
Tok en Er r or s
Displays the total number of Token Errors. Token Errors occur
when an active monitor does not see a token circulating on the
ring before its TVX (Timer, Valid Transmission) time expires
(e.g. a lost frame error has occurred), or sees a recirculating
frame or token. The active monitor is responsible for purging the
ring and issuing a new token.
F r equ en cy Er r or s
Displays the total number of frequency errors. This indicates
that the frequency of the incoming signal deviates excessively
from the adapter’s onboard crystal oscillator. It could indicate an
error in this node’s oscillator, the active monitor, or any node in
between. When the node detects a frequency error, it enters the
monitor contention process.
Tota l
Displays a running total of statistics beginning from the TRXI’s
last power-on.
Accu m u la te
Initiates a new statistic count. The TRXI begins totaling
statistics after you select accumulate.
Delta
Displays the total statistics beginning at the last screen Refresh.
Refr esh 99sec
Displays the time interval between screen counter updates. You
can choose refresh intervals in increments of 3 seconds, with the
maximum interval being 99 seconds.
Page 5-26
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
Selectin g th e Device Sta tistics Cou n ter Mod e
To select the Device Statistics counter mode:
1. Use the arrow keys to highlight Accumulate, Total, or Delta at the
bottom of the screen. The currrent setting appears in the Device
Statistics field at the top of the screen. Only the unused counter
modes appear at the bottom of the screen.
2. Press the Retu r n key. The selected counter mode appears at the
top of the screen.
Settin g th e Refr esh F ield
To set the Refresh field:
1. Use the arrow keys to highlight the REFRESH99sec field at the
bottom of the screen.
2. Press the Sh ift and + keys to increment the time interval or
the - key to decrease the time interval.
3. Press the Retu r n key to save your changes.
Page 5-27
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
5.3.6 Th e Ch a ssis Sta tu s View Scr een
The Chassis Status View screen displays the status of ports 1-24, the
Ring In port, and the Ring Out port. You can also use this screen to
enable the TRXI ports. Figure 5-10 shows the Chassis Status View
Screen.
Flash Image Version: X.XX.XX
TRXI LOCAL MANAGEMENT
PORT STATUS: ADMIN
CHASSIS STATUS VIEW
TEMP:
NORMAL
24
23
22
21
20
19
18
17
16
15
14
13
RO
RI
ON ON ON ON ON ON ON ON ON ON ON ON
12
11
10
9
8
7
6
5
4
3
2
1
ON ON ON ON ON ON ON ON ON ON ON ON
MODE:
MANAGEMENT
ENABLE ALL PORTS
OPERATIONAL
REFRESH99sec
RETURN
Figure 5-10. Chassis Status View Screen
The following sections provide a brief explanation of each field and
instructions for using them.
P or t Sta tu s
Displays the port status as Administrative or Operational.
Tem p
Displays the hub temperature as Normal, Warm, or Hot.
Mod e
Displays the current status view as Operational or Administrative.
En a ble All P or ts
Enables all TRXI ports.
Page 5-28
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
Op er a tion a l
Selects the status view mode as Operational or Administrative.
Refr esh 99sec
Displays the time interval between screen counter updates. You can
choose refresh intervals in increments of 3 seconds, with the
maximum interval being 99 seconds.
Retu r n
Returns the screen to the Device Status screen.
Settin g th e En a ble All P or ts Op tion
To set the Enable All Ports option:
1. Use the arrow keys to highlight Enable All Ports.
2. Press Retu r n to Enable all the TRXI ports.
Settin g th e Op er a tion a l/Ad m in istr a tive Mod e Op tion
To set the Operational/Administrative Mode option:
1. Use the arrow keys to highlight Operational or Administrative.
2. Press Retu r n to select Operational or Administrative. The
selected mode appears in the Mode field.
Settin g th e Refr esh F ield
To set the Refresh field:
1. Use the arrow keys to highlight the REFRESH99sec field at the
bottom of the screen.
2. Press the Sh ift and + keys to increment the time interval or
the - key to decrease the time interval.
3. Press the Retu r n key to save your changes.
Page 5-29
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
5.3.7 Th e Com p on en t Sta tu s View Scr een
The Component Status View screen is a view only screen that displays
the functions operating in the TRXI.
Flash Image Version: X.XX.XX
COMPONENT STATUS VIEW
TRXI LOCAL MANAGEMENT
COMPONENT NAME
TRXI Chassis MGR
TRXI LIM
Network 1
TRXI Protocol Stack
TRXI SNMP Agent
TRXI RMON
REFRESH99sec
RETURN
Figure 5-11. Component Status View Screen
Settin g th e Refr esh F ield
To set the Refresh field:
1. Use the arrow keys to highlight the REFRESH99sec field at the
bottom of the screen.
2. Press the Sh ift and + keys to increment the time interval or
the - key to decrease the time interval.
3. Press the Retu r n key to save your changes.
Page 5-30
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
5.3.8 Th e SNMP Tools Scr een
This section describes specific commands and features within the
SNMP Tools screen. This screen allows you to access management
information bases (MIBs), and varies according to your level of
security access.
The following descriptions outline the super-user management
capabilities. From SNMP Tools you can:
•
•
•
review specifics about object identifiers (OIDs)
edit configurable OIDs
view OIDs sequentially from the originally requested OID.
To access the SNMP Tools Screen from the Features Selection Screen,
use the arrow keys to highlight the SNMP Tool Su p p or t option, then
press the Retu r n key. The SNMP Tools Screen, Figure 5-12, appears.
Flash Image Version: X.XX.XX
TRXI LOCAL MANAGEMENT
SNMP TOOLS
COMMUNITY NAME: public
OID PREPEND: 1.3.6.1
GET SET GETNEXT WALK RECALL-OID STEP CYCLES REPEAT
F6 F7 F8 F9
RETURN
F10
Figure 5-12. SNMP Tools Screen
The following describes the SNMP Tools Screen fields and commands.
Page 5-31
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
SNMP Com m u n ity Na m e
Identifies the community name MIB access level password.
OID P r ep en d
Specifies the number prefix common to all object identifiers (OIDs)
found in a MIB. The prefix ‘1.3.6.1’ is the default. You can modify this
field to suit your needs.
GET
Allows you to retrieve MIB objects, one at a time, using SNMP
protocol.
SET
Lets you edit modifiable MIB objects, using SNMP protocol.
GETNEXT
Displays the next OID in the MIB tree by getting the next SNMP OID
from a remote agent.
WALK
Scrolls you through the MIB, leaf by leaf, from a user-specified object
identifier. Leaves are objects, or instances of objects. After initializing
a walk you see the following categories for each entry:
•
•
•
•
Specified OID — identifies the number tag for that OID.
Size — gives the number of bytes required to store the object.
Data Type — gives the object’s variable type (e.g., int=integer).
Data Value — displays what the object identifier represents.
RECALL-OID
Recalls from memory the last OID used since powering up the board
or re-entering the SNMP Tools screen.
STEP
Displays the MIB, step by step, with specific OID details.
CYCLES
Allows you to specify the number of GET NEXT requests to walk
through and how much time elapses between each request.
REP EAT
Repeats the Get command, allowing you to monitor any changes to a
specific OID.
Page 5-32
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
Th e Secu r ity Access Level
Each MIB component that the TRXI supports (e.g., RMON, DLM, etc.)
has its own “password” for each possible level of access (ranging from
Basic Read-Only to Super-User).
Note: A complete list of Super-User Community Names (also called
Community Strings) resides in the Cabletron proprietary chassis MIB.
The MIB group chCompName provides the names of the MIB
components. The MIB group chCompSUCommStr provides individual
MIB component Community Names/ Strings.
The component information corresponds numerically – by last digit. In
other words, each instance (i.e., OID element) in the chCompName
group indicates its match in the chCompSUCommStr group.
In order to access a specific MIB’s components, you must set the
appropriate MIB password in the COMMUNITY NAME field.
Note: The default Super-User password (public) allows you to access all
MIB components. To change the SNMP Tools screen COMMUNITY
NAME field, you must have Super-User access to Local Management.
To set the SNMP Tools screen COMMUNITY NAME:
1. Use the arrow keys to highlight the field to the right of
COMMUNITY NAME.
2. Enter the Community Name necessary for Super-User access for
any specific MIB (e.g., channelA for Repeater Rev. 4 MIB).
3. Press the Retu r n key. The Community Name changes.
Gettin g a n d Settin g OIDs
To get an OID:
1. Highlight GET, using the arrow keys.
2. Press the Retu r n key. “<GET> OID (=| F9)” appears.
Page 5-33
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
3. Enter an OID either by:
•
using the keyboard to enter the OID.
Sh or tcu t: Save yourself some keystrokes by typing the OID
minus the OID’s prepend (i.e., given an OID prepend of 1.3.6.1,
you enter 2.1.1.4.0, and the Local Management gets the MIB II
sysContact OID 1.3.6.1.2.1.1.4.0).
•
•
pressing F 9 to recall an OID already entered, and using the
keyboard to modify the recalled OID as necessary.
entering an ‘=’ and the OID suffix (e.g., if you enter =2.1.1.4.0,
the OID = 1.3.6.1.2.1.1.4.0). This allows you to digress and not
use the prepend.
4. Press the Retu r n key. If there is no instance of that OID, the TRXI
displays “MIB_NO_INSTANCE.” Otherwise, the TRXI displays
that OID’s data type, length, and value.
To get the next OID:
1. Highlight GETNEXT, using the arrow keys.
2. Press the Retu r n key. “<GETNEXT> OID (=| F9)” appears.
3. Enter the OID.
4. Press the Retu r n key. If that OID does not exist, the TRXI
displays “MIB_NO_INSTANCE”. Otherwise the TRXI displays
that OID’s data type, length, and value.
Sh or tcu t: If you have previously entered an OID, press F 9 to
recall that entry. You can use the arrow keys to modify the recalled
OID, or if you have not previously entered the OID, type the OID
minus the OID’s prepend.
To set an OID [information in brackets provides an example]:
1. Highlight SET, using the arrow keys.
2. Press the Retu r n key. “<SET> OID (=| F9)” appears.
Page 5-34
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
3. Enter an OID. [1.3.6.1.2.1.1.4.0]
4. Press the Retu r n key. If that OID does not exist, the TRXI
displays “MIB_NO_INSTANCE”. Otherwise the TRXI displays:
{INteger String Null OId IP address Counter Gauge Timeticks
OPaque}
“DATA TYPE (name):”.
Sh or tcu t: If you have previously entered an OID, press F 9 to
recall that entry. You can use the arrow keys to modify the recalled
OID, or if you have not previously entered the OID, save yourself
some keystrokes by typing the OID minus the OID’s prepend.
5. Enter the OID’s Da ta Typ e. [The sysContact Da ta Typ e is
String.]
Note: When setting a String, SNMP tools requests the kind of data
you plan to enter — HEX or ASCII. [In this example choose ASCII.]
6. Press the Retu r n key. The TRXI displays “SNMP OID DATA.”
7. Enter the Da ta , or value of the OID. [Type in a sysContact. This
OID allows for a String of up to 12 characters.]
8. Press the Retu r n key. If the TRXI accepts the entry, it displays
“<SET> OPERATION CODE: XXXX <OK>”; otherwise, an error
message appears.
Scr ollin g Th r ou gh Mib OIDs
Viewing several object identifiers at one time allows you to quickly
scan a MIB for the information that you need. The SNMP Tools screen
provides several scroll options:
•
•
Walk — scrolls through OIDs sequentially, from the initial OID.
Cycle — allows you to specify how many GetNext commands to
cycle through for one OID.
•
Step — pages through the MIB, one OID at a time.
Page 5-35
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
To walk through the MIB:
1. Highlight WALK, using the arrow keys.
2. Press the Retu r n key. “<INITIAL> OID (=| F9)” appears.
3. Enter the OID.
4. Press the Retu r n key. Local Management begins walking through
the sublayers of the MIB available from the specified OID. Each
OID in the list displays the specified OID, its size, its data type, and
the data value.
5. Press any key to stop the walk, or wait for “***MIB WALK
COMPLETED***” to appear on the screen.
To cycle through:
1. Highlight CYCLES, using the arrow keys.
2. Press the Retu r n key. “ENTER CYCLE COUNT:” appears.
3. Enter the number of OID cycles that you want to scroll through.
4. Press the Retu r n key. “ENTER CYCLE DELAY:” appears.
5. Enter the delay that you want (in seconds) between get next
requests.
6. Press the Retu r n key. “<INITIAL> OID (=| F9)” appears.
7. Enter the OID.
8. Press the Retu r n key.
To step through:
1. Highlight GETNEXT, using the arrow keys.
2. Press the Retu r n key. “<GETNEXT> OID (=| F9)” appears.
3. Enter the OID (only the suffix is necessary).
Page 5-36
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCAL MANAGEMENT
4. Press the Retu r n key. The initial OID details, including its size,
data type, and data value, appear.
5. Highlight STEP , using the arrow keys.
6. Press the Retu r n key to page through the MIB to the next OID.
Page 5-37
Download from Www.Somanuals.com. All Manuals Search And Download.
|