Introduction  
This appendix contains local management information that is specific to the  
9F120-08, 9F122-12 and 9F125-08 MicroLAN modules.  
Default Interface Codes  
The Default Interface field on the General Configuration Screen allows you to  
enter a number (one through three). Each number represents a default interface  
for the selected module. The table below lists the numbers you can enter, each  
number’s corresponding interface, and a brief description of that interface. The  
default for this field is NONE, meaning no default interface selected.  
Table 1. 9F12x-xx MicroLAN Module Default Interface Codes  
Number  
Interface  
Description  
1
2
3
SMB-1  
SMB-10  
FNB  
1 mbps System Management Bus  
10 mbps System Management Bus  
Flexible Network Bus (dual attached)  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
9F120-08 / 9F122-12 / 9F125-08 Module Specific Information  
FNB Resource Configuration Codes  
All of the MicroLAN Modules described in this appendix physically attach to the  
FNB-1 and the FNB-2 on the SmartSwitch 9000 backplane. By default, the module  
inserts into four rings (the primary and secondary rings of the FNB-1 and the  
FNB-2). The FNB Resource Configuration Screen allows you to customize this  
configuration to your particular needs.  
The FNB Resource Configuration Screen allows you to:  
Select the rings (primary or secondary) of each FNB to which the module will  
attach  
Determine whether the module will insert into those rings or bypass them  
Select the ring where the MAC will reside  
The terms INSERT and BYPASS refer to relays that are located on the module.  
INSERT causes a relay to connect the module’s front panel ports to the selected  
ring. BYPASS causes a relay to disconnect the module’s front panel ports from the  
selected ring.  
INSERT:  
FNB Ring  
Relay  
Front  
Panel  
Ports  
BYPASS:  
FNB Ring  
Relay  
Front  
Panel  
Ports  
The FNB Resource Configuration Screen lists all possible connections a module  
can support on the FNB, displays the current connection, and allows you to  
change the connection. Table 2 lists and describes the FDDI Connections from  
which you can select.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
9F120-08 / 9F122-12 / 9F125-08 Module Specific Information  
Table 2. 9F12x-xx MicroLAN Module FNB Resource Configuration Codes  
Configuration  
ID  
FDDI Connections  
Description  
The module is attached, but not inserted, to  
the primary ring on the FNB-1. The module is  
attached, but not inserted, to the primary ring  
on the FNB-2. The MAC resides on FNB-1.  
1
FNB 1 Pri. (MAC) Byp. ,  
FNB 2 Pri. (No MAC) Byp.  
The module is attached to the FNB-1 primary  
ring and the FNB-2 primary ring. The switch  
that inserts the module into the FNB-1 is  
turned off. The switch that inserts the module  
into the FNB-2 is turned on. The MAC resides  
on FNB-1.  
2
FNB 1 Pri. (MAC) Byp. ,  
FNB 2 Pri. (No MAC) Ins.  
The module is attached to the FNB-1 primary  
ring and the FNB-2 primary ring. The switch  
that inserts the module into the FNB-1 is  
turned on. The switch that inserts the module  
into the FNB-2 is turned off. The MAC resides  
on FNB-1.  
3
4
5
6
FNB 1 Pri. (MAC) Ins. ,  
FNB 2 Pri. (No MAC) Byp.  
The module is attached to the FNB-1 primary  
ring and the FNB-2 primary ring. The switch  
that inserts the module into the FNB-1 is  
turned on. The switch that inserts the module  
into the FNB-2 is turned on. The MAC resides  
on FNB-1.  
FNB 1 Pri. (MAC) Ins. ,  
FNB 2 Pri. (No MAC) Ins.  
The module is attached to the FNB-1 primary  
ring and the FNB-2 primary ring. The switch  
that inserts the module into the FNB-1 is  
turned off. The switch that inserts the module  
into the FNB-2 is turned off. The MAC resides  
on FNB-2.  
FNB 1 Pri. (No MAC) Byp. ,  
FNB 2 Pri. (MAC) Byp.  
The module is attached to the FNB-1 primary  
ring and the FNB-2 primary ring. The switch  
that inserts the module into the FNB-1 is  
turned off. The switch that inserts the module  
into the FNB-2 is turned on. The MAC resides  
on FNB-2.  
FNB 1 Pri. (No MAC) Byp. ,  
FNB 2 Pri. (MAC) Ins.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
9F120-08 / 9F122-12 / 9F125-08 Module Specific Information  
Table 2. 9F12x-xx MicroLAN Module FNB Resource Configuration Codes (Continued)  
Configuration  
FDDI Connections  
Description  
ID  
The module is attached to the FNB-1 primary  
ring and the FNB-2 primary ring. The switch  
that inserts the module into the FNB-1 is  
turned on. The switch that inserts the module  
into the FNB-2 is turned off. The MAC resides  
on FNB-2.  
7
FNB 1 Pri. (No MAC) Ins. ,  
FNB 2 Pri. (MAC) Byp.  
The module is attached to the FNB-1 primary  
ring and the FNB-2 primary ring. The switch  
that inserts the module into the FNB-1 is  
turned on. The switch that inserts the module  
into the FNB-2 is turned on. The MAC resides  
on FNB-2.  
8
FNB 1 Pri. (No MAC) Ins. ,  
FNB 2 Pri. (MAC) Ins.  
The module is attached to the FNB-1 primary  
ring and the FNB-2 secondary ring. The  
switch that inserts the module into the FNB-1  
is turned off. The switch that inserts the  
module into the FNB-2 is turned off. The  
MAC resides on FNB-1.  
9
FNB 1 Pri. (MAC) Byp. ,  
FNB 2 Sec. (No MAC) Byp.  
The module is attached to the FNB-1 primary  
ring and the FNB-2 secondary ring. The  
switch that inserts the module into the FNB-1  
is turned off. The switch that inserts the  
module into the FNB-2 is turned on. The MAC  
resides on FNB-1.  
10  
11  
12  
FNB 1 Pri. (MAC) Byp. ,  
FNB 2 Sec. (No MAC) Ins.  
The module is attached to the FNB-1 primary  
ring and the FNB-2 secondary ring. The  
switch that inserts the module into the FNB-1  
is turned on. The switch that inserts the  
module into the FNB-2 is turned off. The  
MAC resides on FNB-1.  
FNB 1 Pri. (MAC) Ins. ,  
FNB 2 Sec. (No MAC) Byp.  
The module is attached to the FNB-1 primary  
ring and the FNB-2 secondary ring. The  
switch that inserts the module into the FNB-1  
is turned on. The switch that inserts the  
module into the FNB-2 is turned on. The MAC  
resides on FNB-1.  
FNB 1 Pri. (MAC) Ins. ,  
FNB 2 Sec. (No MAC) Ins.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
9F120-08 / 9F122-12 / 9F125-08 Module Specific Information  
Table 2. 9F12x-xx MicroLAN Module FNB Resource Configuration Codes (Continued)  
Configuration  
ID  
FDDI Connections  
Description  
The module is attached to the FNB-1 primary  
ring and the FNB-2 secondary ring. The  
switch that inserts the module into the FNB-1  
is turned off. The switch that inserts the  
module into the FNB-2 is turned off. The  
MAC resides on FNB-2.  
13  
14  
15  
16  
17  
18  
FNB 1 Pri. (No MAC) Byp. ,  
FNB 2 Sec. (MAC) Byp.  
The module is attached to the FNB-1 primary  
ring and the FNB-2 secondary ring. The  
switch that inserts the module into the FNB-1  
is turned off. The switch that inserts the  
module into the FNB-2 is turned on. The MAC  
resides on FNB-2.  
FNB 1 Pri. (No MAC) Byp. ,  
FNB 2 Sec. (MAC) Ins.  
The module is attached to the FNB-1 primary  
ring and the FNB-2 secondary ring. The  
switch that inserts the module into the FNB-1  
is turned on. The switch that inserts the  
module into the FNB-2 is turned off. The  
MAC resides on FNB-2.  
FNB 1 Pri. (No MAC) Ins. ,  
FNB 2 Sec. (MAC) Byp.  
The module is attached to the FNB-1 primary  
ring and the FNB-2 secondary ring. The  
switch that inserts the module into the FNB-1  
is turned on. The switch that inserts the  
module into the FNB-2 is turned on. The MAC  
resides on FNB-2.  
FNB 1 Pri. (No MAC) Ins. ,  
FNB 2 Sec. (MAC) Ins.  
The module is attached to the FNB-1  
secondary ring and the FNB-2 primary ring.  
The switch that inserts the module into the  
FNB-1 is turned off. The switch that inserts the  
module into the FNB-2 is turned off. The  
MAC resides on FNB-1.  
FNB 1 Sec. (MAC) Byp. ,  
FNB 2 Pri. (No MAC) Byp.  
The module is attached to the FNB-1  
secondary ring and the FNB-2 primary ring.  
The switch that inserts the module into the  
FNB-1 is turned off. The switch that inserts the  
module into the FNB-2 is turned on. The MAC  
resides on FNB-1.  
FNB 1 Sec. (MAC) Byp. ,  
FNB 2 Pri. (No MAC) Ins.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
9F120-08 / 9F122-12 / 9F125-08 Module Specific Information  
Table 2. 9F12x-xx MicroLAN Module FNB Resource Configuration Codes (Continued)  
Configuration  
FDDI Connections  
Description  
ID  
The module is attached to the FNB-1  
secondary ring and the FNB-2 primary ring.  
The switch that inserts the module into the  
FNB-1 is turned on. The switch that inserts the  
module into the FNB-2 is turned off. The  
MAC resides on FNB-1.  
19  
FNB 1 Sec. (MAC) Ins. ,  
FNB 2 Pri. (No MAC) Byp.  
The module is attached to the FNB-1  
secondary ring and the FNB-2 primary ring.  
The switch that inserts the module into the  
FNB-1 is turned on. The switch that inserts the  
module into the FNB-2 is turned on. The MAC  
resides on FNB-1.  
20  
21  
22  
23  
24  
FNB 1 Sec. (MAC) Ins. ,  
FNB 2 Pri. (No MAC) Ins.  
The module is attached to the FNB-1  
secondary ring and the FNB-2 primary ring.  
The switch that inserts the module into the  
FNB-1 is turned off. The switch that inserts the  
module into the FNB-2 is turned off. The  
MAC resides on FNB-2.  
FNB 1 Sec. (No MAC) Byp. ,  
FNB 2 Pri. (MAC) Byp.  
The module is attached to the FNB-1  
secondary ring and the FNB-2 primary ring.  
The switch that inserts the module into the  
FNB-1 is turned off. The switch that inserts the  
module into the FNB-2 is turned on. The MAC  
resides on FNB-2.  
FNB 1 Sec. (No MAC) Byp. ,  
FNB 2 Pri. (MAC) Ins.  
The module is attached to the FNB-1  
secondary ring and the FNB-2 primary ring.  
The switch that inserts the module into the  
FNB-1 is turned on. The switch that inserts the  
module into the FNB-2 is turned off. The  
MAC resides on FNB-2.  
FNB 1 Sec. (No MAC) Ins. ,  
FNB 2 Pri. (MAC) Byp.  
The module is attached to the FNB-1  
secondary ring and the FNB-2 primary ring.  
The switch that inserts the module into the  
FNB-1 is turned on. The switch that inserts the  
module into the FNB-2 is turned on. The MAC  
resides on FNB-2.  
FNB 1 Sec. (No MAC) Ins. ,  
FNB 2 Pri. (MAC) Ins.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
9F120-08 / 9F122-12 / 9F125-08 Module Specific Information  
Table 2. 9F12x-xx MicroLAN Module FNB Resource Configuration Codes (Continued)  
Configuration  
ID  
FDDI Connections  
Description  
The module is attached to the FNB-1  
secondary ring and the FNB-2 secondary ring.  
The switch that inserts the module into the  
FNB-1 is turned off. The switch that inserts the  
module into the FNB-2 is turned off. The  
MAC resides on FNB-1.  
25  
26  
27  
28  
29  
30  
FNB 1 Sec. (MAC) Byp. ,  
FNB 2 Sec. (No MAC) Byp.  
The module is attached to the FNB-1  
secondary ring and the FNB-2 secondary ring.  
The switch that inserts the module into the  
FNB-1 is turned off. The switch that inserts the  
module into the FNB-2 is turned on. The MAC  
resides on FNB-1.  
FNB 1 Sec. (MAC) Byp. ,  
FNB 2 Sec. (No MAC) Ins.  
The module is attached to the FNB-1  
secondary ring and the FNB-2 secondary ring.  
The switch that inserts the module into the  
FNB-1 is turned on. The switch that inserts the  
module into the FNB-2 is turned off. The  
MAC resides on FNB-1.  
FNB 1 Sec. (MAC) Ins. ,  
FNB 2 Sec. (No MAC) Byp.  
The module is attached to the FNB-1  
secondary ring and the FNB-2 secondary ring.  
The switch that inserts the module into the  
FNB-1 is turned on. The switch that inserts the  
module into the FNB-2 is turned on. The MAC  
resides on FNB-1.  
FNB 1 Sec. (MAC) Ins. ,  
FNB 2 Sec. (No MAC) Ins.  
The module is attached to the FNB-1  
secondary ring and the FNB-2 secondary ring.  
The switch that inserts the module into the  
FNB-1 is turned off. The switch that inserts the  
module into the FNB-2 is turned off. The  
MAC resides on FNB-2.  
FNB 1 Sec. (No MAC) Byp. ,  
FNB 2 Sec. (MAC) Byp.  
The module is attached to the FNB-1  
secondary ring and the FNB-2 secondary ring.  
The switch that inserts the module into the  
FNB-1 is turned off. The switch that inserts the  
module into the FNB-2 is turned on. The MAC  
resides on FNB-2.  
FNB 1 Sec. (No MAC) Byp. ,  
FNB 2 Sec. (MAC) Ins.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
9F120-08 / 9F122-12 / 9F125-08 Module Specific Information  
Table 2. 9F12x-xx MicroLAN Module FNB Resource Configuration Codes (Continued)  
Configuration  
FDDI Connections  
Description  
ID  
The module is attached to the FNB-1  
secondary ring and the FNB-2 secondary ring.  
The switch that inserts the module into the  
FNB-1 is turned on. The switch that inserts the  
module into the FNB-2 is turned off. The  
MAC resides on FNB-2.  
31  
FNB 1 Sec. (No MAC) Ins. ,  
FNB 2 Sec. (MAC) Byp.  
The module is attached to the FNB-1  
secondary ring and the FNB-2 secondary ring.  
The switch that inserts the module into the  
FNB-1 is turned on. The switch that inserts the  
module into the FNB-2 is turned on. The MAC  
resides on FNB-2.  
32  
FNB 1 Sec. (No MAC) Ins. ,  
FNB 2 Sec. (MAC) Ins.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
9F120-08 / 9F122-12 / 9F125-08 Module Specific Information  
Module Specific Configuration Screen  
In the FNB Resource Configuration Screen, you determine which of the two FNB  
rings contains the MAC. The 9F120 MicroLAN Module Specific Configuration  
Screen allows you to assign one of the two FNB rings (either the ring that contains  
the MAC or the ring that does not contain the MAC) to each of the module’s M-  
ports. The default ring that is assigned to each of the module’s M-ports is the ring  
that contains the MAC.  
SmartSwitch 9000 LOCAL MANAGEMENT  
Module Specific Configuration  
Module Name: 9F120-08  
Slot Number: 12  
Firmware Revision: 01.01.01  
BOOTPROM Revision: 00.00.04  
FNB 1 Pri. (MAC)  
Ins. , FNB 2 Pri. (No MAC) Ins.  
PORT#  
PATH  
CONNECT STATE  
1
2
3
4
5
6
7
8
[MAC-1]  
[MAC-1]  
[MAC-1]  
[MAC-1]  
[MAC-1]  
[MAC-1]  
[MAC-1]  
[MAC-1]  
CON  
CON  
CON  
CON  
CON  
CON  
CON  
CON  
SAVE  
RETURN  
Figure 1. 9F120 MicroLAN Module Specific Statistics Screen  
To assign an FNB ring to a module’s M-port:  
1. Use the arrow keys to highlight the PATH field next to the desired port.  
2. Press the SPACE BAR to toggle to the desired ring (either MAC-1 or No  
MAC).  
3. Press the Return key. Repeat steps 1-3 to assign an FNB ring to other M-ports.  
4. Use the arrow keys to highlight SAVE at the bottom of the screen and press  
the Return key. When the message “SAVED OK” appears, the edits you have  
made are saved. If you exit without saving, the message “NOT SAVED --  
PRESS SAVE TO KEEP CHANGES” appears. If you proceed to exit without  
saving, your edits will be lost.  
5. Use the arrow keys to highlight RETURN and press the Return key.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
9F120-08 / 9F122-12 / 9F125-08 Module Specific Information  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Billion Electric Company Network Router BIPAC 645 User Manual
Black Decker Power Screwdriver SD1000 User Manual
Bogen Musical Instrument CAM8 User Manual
BOXLIGHT Projector CP 324i User Manual
Briggs Stratton Lawn Mower S21 User Manual
Brother Sewing Machine CS 8150 User Manual
Bryant Boiler 234 D User Manual
Canon Microphone MA 300 User Manual
Casablanca Fan Company Fan Casablanca 19th Century User Manual
Cateye Cyclometer CC TR200DW V2c User Manual