MMAC-Plus™ 9F106-01
Two Port FDDI Router
User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Notice
FCC Notice
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial environment.
This equipment uses, generates, and can radiate radio frequency energy and if not installed in
accordance with the operator’s manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause interference in which case the user
will be required to correct the interference at his own expense.
WARNING: Changes or modifications made to this device which are not expressly approved by the
party responsible for compliance could void the user’s authority to operate the equipment.
VCCI Notice
This equipment is in the 1st Class Category (information equipment to be used in commercial and/or
industrial areas) and conforms to the standards set by the Voluntary Control Council for Interference
by Information Technology Equipment (VCCI) aimed at preventing radio interference in commercial
and/or industrial areas.
Consequently, when used in a residential area or in an adjacent area thereto, radio interference may be
caused to radios and TV receivers, etc.
Read the instructions for correct handling.
ii
Download from Www.Somanuals.com. All Manuals Search And Download.
Notice
DOC Notice
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital
apparatus set out in the Radio Interference Regulations of the Canadian Department of
Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables
aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique
édicté par le ministère des Communications du Canada.
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Chapter 1
Chapter 2
Chapter 3
Introduction
Features........................................................................................................................... 1-1
Related Manuals............................................................................................................ 1-4
Getting Help .................................................................................................................. 1-4
Installing the MMAC-Plus Module
The Reset Switch ........................................................................................................... 2-3
Local Management Console ........................................................................................ 2-3
Installing an FPIM......................................................................................................... 2-6
Operation
Flexible Network Bus (FNB)........................................................................................ 3-2
System Management Buses ......................................................................................... 3-2
System Diagnostic Controller...................................................................................... 3-2
DC/DC Converter ........................................................................................................ 3-2
FNB Interface................................................................................................................. 3-3
CPU ................................................................................................................................. 3-3
Chapter 4
Chapter 5
LANVIEW LEDs
Specifications
Safety............................................................................................................................... 5-1
Service............................................................................................................................. 5-1
Physical........................................................................................................................... 5-2
Dimensions ............................................................................................................. 5-2
Weight...................................................................................................................... 5-2
Environment........................................................................................................... 5-2
Appendix A FPIM Specifications
FPIM-00 ......................................................................................................................... A-1
FPIM-02 and FPIM-04.................................................................................................. A-2
FPIM-05 ......................................................................................................................... A-3
v
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1
Introduction
The 9F106-01 module, shown in Figure 1-1, is a two port FDDI router. One front
panel network connection can be made to this module and routed to any other
MMAC-Plus module via the FNB bus.
Features
Processor
The 9F106-01 is equipped with an advanced IDT R4600 Fourth Generation 64 bit
RISC microprocessor. This microprocessor provides a platform for all
management functions within a scalable RISC-based architecture.
System Management
The 9F106-01 provides an interface to the System Management Bus (SMB-1) for
intermodule management.
Connectivity
The 9F106-01 provides one dual attached FDDI interface using two standard
Cabletron FPIMs.
Routing
The 9F106-01 provides Routing between the front panel interface and/or to any
other module in the chassis via FNB -1 or FNB -2 of the FNB bus. IEEE 802.1d
Spanning Tree Protocol is supported in all bridging functions.
1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Management Information Base (MIB) Support
The 9F106-01 module provides MIB support including the following:
•
•
IETF FDDI MIB
IETF MIB II
NOTE
For a complete list of supported MIBs, refer to the release notes provided in the
module package.
LANVIEW LEDs
The 9F106-01 uses LANVIEW: the Cabletron Systems built-in visual diagnostic
and status monitoring system. With LANVIEW LEDs, you can quickly identify
the device, port, and physical layer status at a glance.
Hot Swapping
The 9F106-01 can be installed or removed from the chassis while the MMAC-Plus
is powered up without affecting the operation of the remaining modules in the
chassis.
1-2
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Related Manuals
The manuals listed below should be used to supplement the procedures and
technical data contained in this manual.
MMAC-Plus Installation Guide
MMAC-Plus Operations Guide
MMAC-Plus 9C300-1 Environmental Module User’s Guide
MMAC-Plus 9C214-1 AC Power Supply User’s Guide
Cisco Systems R4500 manuals - CRM-DOC or CRM-CDROM
Getting Help
If you need additional support with the MMAC-Plus, or if you have any
questions, comments or suggestions concerning this manual, feel free to contact
Cabletron Systems Technical Support:
By phone:
(603) 332-9400
By CompuServe®: GO CTRON from any ! prompt
By Internet mail:
By mail:
Cabletron Systems, Inc.
P.O. Box 5005
Rochester, NH 03867-0505
1-4
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2
Installing the MMAC-Plus Module
The MMAC-Plus module may be installed into any of the 14 slots that are
available. To install, follow the steps below:
1. Remove the blank panel, covering the slot that the module is being mounted
in. All other slots must be covered, if modules are not being installed, to
ensure proper airflow and cooling.
2. Carefully remove the module from the shipping box. (Save the box and
packing materials in the event the module must be reshipped.)
3. Attach one end of the ESD wrist strap packaged with the MMAC-Plus chassis
to your wrist. Plug the other end into the ESD Wrist Strap Grounding
receptacle in the lower right corner of the MMAC-Plus Chassis shown in
Figure 1.
4. Remove the module from the plastic bag. Observe all precautions to prevent
damage from Electrostatic Discharge (ESD).
5. Carefully examine the module, checking for damage. If any damage exists,
DO NOT install the module. Contact Cabletron Systems Technical Support
immediately.
6. Before installing the MMAC-Plus cards into the chassis, ensure that the
bottom and top plastic tabs are unlocked. Slide the card into an available slot
and ensure that the circuit card is between the card guides, as shown in
Figure 1. Check both the upper and lower tracks. Take care that the module
slides in straight and engages the backplane connectors properly. Lock down
the top and bottom plastic tabs at the same time, applying even pressure.
2-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the MMAC-Plus Module
Plastic Tabs
L
L
L
I
I
Jack for ESD
wrist strap
Metal Back-Panel
Circuit Card
Card Guides
Warning:
Ensure that the circuit card is between the card guides.
Lock down the top and bottom plastic tabs
at the same time, applying even pressure.
Figure 2-1. Installing the MMAC-Plus Module
2-2
Download from Www.Somanuals.com. All Manuals Search And Download.
The Reset Switch
The Reset Switch
The Reset switch is located on the front panel, under the top plastic tab, as shown
•
•
Pressing the Reset switch twice within three seconds causes the processor to
reset.
Pressing and holding the switch on for three or more seconds causes the
module to shutdown. Pressing and holding again for three seconds restarts the
module.
SNMP management may be used to disable this switch to enhance module
security.
Reset Switch
SMB
CPU
Figure 2-2. The Reset Switch
Local Management Console
Local Management is accessed by attaching a management console at the RJ-45
CON port of the 9F106-01. The console connection supports a Digital Equipment
Corporation VT 320™ terminal or PC emulation of one of these terminals.
terminal is a Digital Equipment Corporation VT 320™ terminal, press F3 to access
the Setup Directory. If you have a terminal emulation of the Digital Equipment
terminals, refer to your equipment user manual for setup procedures.
2-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the MMAC-Plus Module
Table 2-1. Terminal Setup Requirements
Men u
F u n ction
Selection
Display
Setup:
Columns
Controls
Auto Wrap
Text Cursor
80 Columns
Interpret Controls
No Auto Wrap
Cursor
General
Setup:
Mode
7 Bit Control
Cursor Keys
Normal Cursor
Keys
Communications
Setup:
Transmit
Receive
XOFF
Transmit = 9600
Receive = Transmit
any option
Bits, Parity
Stop Bit
Local Echo
Port
8 Bits, No Parity
1 Stop Bit
No Local Echo
EIA Port, Data Leads
Only
DEC-423, Data
Leads only
Transmit
any option
Auto Answerback
No Auto Answerback
Keyboard
Setup:
Auto Repeat
Keyclick
any option
any option
Margin Bell
Warning Bell
Auto Answerback
Margin Bell
Warning Bell
No Auto Answerback
2-4
Download from Www.Somanuals.com. All Manuals Search And Download.
Local Management Console
An RJ-45 connector provides a CON interface to the management terminal.
Pin1
RJ-45 CON PORT
RJ-45TO 25 PIN
CABLE
FEMALE - 25 Pin
"D" Shell Connector
2
3
TRANSMIT
RECEIVE
4
1
RECEIVE
TRANSMIT
SIGNAL GROUND
5
7
SIGNAL GROUND
DATA SET READY
2
6
20 DATA TERMINAL READY
5
CLEAR TO SEND
DATA TERMINAL READY
CONPORT
RJ-45
LOCAL MANAGENT
CONSOLE
RECEIVE
TRANSMIT
1
4
2
3
TRANSMIT
RECEIVE
SIGNAL GROUND
DATA SET READY
5
5
SIGNAL GROUND
READY TO SEND
2
6
7
8
DATA TERMINAL READY
CLEAR TO SEND
FEMALE - DB-9
(9-Pin Connector)
RJ-45 TO 9 PIN
CABLE
Figure 2-3. Console Cable Pinouts
Connect the console to the module as follows:
1. Attach the male RJ-45 connector to the CON port of the 9F106-01.
2. Attach the female end (25-pin or 9-pin, as applicable) to the terminal.
Refer to the Cisco Systems documentation for information on configuring this
module.
2-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the MMAC-Plus Module
Installing an FPIM
The 9F106-01 module is shipped without FPIMs. To install an FPIM, follow the
procedure below:
1. Remove the module if it is installed in the MMAC-Plus chassis.
2. Remove the blank front cover over the FPIM slot.
seated firmly before tightening the two mounting screws.
Figure 2-4. Installing an FPIM
2-6
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3
Operation
The 9F106-01 FDDI module is a two port router for the MMAC-Plus. One front
panel network connection can be made to this module and routed to any other
MMAC-Plus module via the FNB bus.
SMB-1
DC/DC
System
Converter
Diagnostic
Controller
A
FNB-1 or
FNB-2
DAS
Interface
CPU
B
Front Panel CON Ports
Figure 3-1. 9F106-01 Block Diagram
3-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Flexible Network Bus (FNB)
The FNB consists of two dual FDDI networks, the FNB-1 and FNB-2, providing
up to 400 Mbps of data bandwidth. These FDDI networks are 100% ANSI FDDI-
compliant, supporting SMT (version 7.3), MAC, PHY, and PMD standards. This
allows the FNB to traverse multiple MMAC-Plus hubs, or connect to any ANSI
FDDI-compliant device, through standard A/B port connections.
System Management Buses
The SMB-1 is a 1 Mbps management bus located within the MMAC-Plus. This bus
is utilized by all diagnostic controllers in the system. These include connectivity
modules, power supply modules, and the environmental module. The SMB-1
transports inter-chassis information between system components, such as power
and environmental information, as well as diagnostic messages. Periodic
loop-back tests are performed by all modules that share this bus to ensure the
validity of SMB-1.
System Diagnostic Controller
This diagnostic controller is composed of a Z-80 microprocessor and its
supporting logic. The diagnostic controller is designed to control the power-up
sequencing of modules, monitor the 9F106-01 input and output power
parameters, keep watch over the main host processor, as well as monitor the
temperature and control the SMB LANVIEW diagnostic LED. The information
gathered by the diagnostic controller is available to the network manager via
local/remote management and the LCD located on the Environmental Module.
The 9F106-01 have been designed so that in the event of a diagnostic controller
fault, the modules will continue to function.
DC/DC Converter
The DC/DC converter converts the 48 VDC on the system power bus to the
necessary operating voltages for its host network services module. The diagnostic
controller controls the operation of the DC/DC converter.
3-2
Download from Www.Somanuals.com. All Manuals Search And Download.
FNB Interface
FNB Interface
MMAC-Plus modules are designed with one of two attachment policies. One
allows dual attachment of a module to either FNB-1 or FNB-2; the second allows
dual attachment to both FNB-1 and FNB-2. The 9F106-01 has one dual attachment
to the FNB backplane, connecting to either FNB-1 or FNB-2. The module can
insert into the FNB or bypass it. These flexible configuration options make the
MMAC-Plus ideal for networks designed to Bridge/Route multiple lower speed
LANs to FDDI and/or networks designed using an FDDI collapsed backbone.
CPU
The CPU provides all forwarding/filtering decisions, the SNMP protocol stacks,
as well as support for industry standard MIBs.
3-3
Download from Www.Somanuals.com. All Manuals Search And Download.
LANVIEW LEDs
The functions of the System Management Bus (SMB) and CPU LEDs are listed in
Table 4-1. SMB and CPU LEDs
LED Color
Green
State
Description
Fully operational.
Functional
Crippled
Booting
Reset
Yellow (Flashing)
Yellow
Conditional FDDI fault *.
Booting.
Red
Normal power-up reset.
FDDI Fault (FNB is down).
Module powered off.
Red (Flashing)
Off
Failed
Power off
* Front Panel FDDI down.
Table 4-2. FNB Receive LED
LED Color
Yellow (Flashing)
Off
State
Activity (Flashing rate indicates rate of activity).
No activity
The function of the FNB Transmit LED is listed in Table 4-3.
Table 4-3. FNB Transmit LED
LED Color
State
Green (Flashing)
Off
Activity (Flashing rate indicates rate of activity).
No activity
4-2
Download from Www.Somanuals.com. All Manuals Search And Download.
LANVIEW LEDs
Table 4-4. FDDI Receive LED
LED Color
State
Yellow (Flashing)
Off
Activity (Flashing rate indicates rate of activity).
No activity
Table 4-5. FDDI Transmit LED
LED Color
State
Green (Flashing)
Off
Activity (Flashing rate indicates rate of activity).
No activity
4-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5
Specifications
Safety
It is the responsibility of the person who sells the system to which the module will
be a part to ensure that the total system meets allowed limits of conducted and
radiated emissions.
!
CAUTION
This equipment meets the following safety requirements:
•
•
•
•
•
•
•
•
UL 1950
CSA C22.2 No. 950
EN 60950
IEC 950
EMI Requirements of FCC Part 15 Class A
EN 55022 Class A
VCCI Class I
EMC the following requirements:
EN 50082-1
IEC 801-2 ESD
IEC 801-3 Radiated susceptibility
IEC 801-4 EFT
Service
MTBF (MHBK-217E): >200,000 hrs.
MTTR: <0.5 hr.
5-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
Physical
Dimensions
35.0 D x 44.0 H x 3.0 W centimeters
(13.8 D x 17.4 H x 1.2 W inches)
Weight
Unit:
Shipping:
1.36 kg. (3 lb)
1.81 kg. (4 lb)
Environment
Operating Temperature 5 to 40° C
Storage Temperature
Relative Humidity
-30 to 90° C
5% to 95% non-condensing
5-2
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A
FPIM Specifications
This MMAC-Plus module uses Fiber Port Interface Modules (FPIM) to provide
front panel cable connections. The FPIMs are user-installable. See the section
titled Installing an FPIM on page 2-6.
FPIM-00
The FPIM-00 has a MIC style connector supporting a multimode fiber connection.
Table A-1. FPIM-00 Specifications
Worst
Case
Worst Case
Budget
Typical
Budget
Parameter
Receive
Typical Value
-30.5 dBm
-28.0 dBm
-8.2 dBm
—
—
—
Sensitivity
Peak Input
Power
-7.6 dBm
—
A-1
Download from Www.Somanuals.com. All Manuals Search And Download.
FPIM Specifications
Table A-2. Transmitter Power Parameters
Worst
Case
Worst Case
Budget
Typical
Budget
Parameter
Typical Value
50/125 µm
-13.0 dBm
-15.0 dBm 13.0 dB
-12.0 dBm 16.0 dB
17.5 dB
20.5 dB
23.5 dB
fiber
62.5/125 µm
fiber
-10.0 dBm
100/140 µm
fiber
-7.0 dBm
-9.0 dBm
19.0 dB
Error Rate
Better than 10-10
The link distance is up to 2 kilometers on the multimode fiber-optic cable as
specified by ANSI MMF-PMD.
FPIM-02 and FPIM-04
The FPIM-02 has an RJ-45 connector supporting an Unshielded Twisted Pair
(UTP) connection. The FPIM-04 has an RJ-45 connector supporting a Shielded
Table A-3. FPIM-04 Pinouts
Pin Number
Represents
Transmit+
Pin Number
Represents
NA
1
2
3
4
5
6
7
8
Transmit-
NA
NA
Receive+
Receive-
NA
The link distance is up to 100 meters on unshielded twisted pair cable as specified
by ANSI TP-PMD.
A-2
Download from Www.Somanuals.com. All Manuals Search And Download.
FPIM-05
FPIM-05
The FPIM-05 has a MIC style connector supporting a Single-mode fiber
Table A-4. FPIM-05 Specifications
Parameter
Typical
1300 nm
Minimum
Maximum
Transmitter Peak Wave
Length
1270 nm
1330 nm
Spectral Width
Rise Time
60 nm
-
100 nm
5.0 nsec
5.0 nsec
50.7%
3.0 nsec
2.7 nsec
2.2 nsec
49.6%
Fall Time
2.5 nsec
Duty Cycle
Bit Error Rate
50.1%
Better than 10-10
The link distance is up to 40 kilometers (max) and 25 kilometers (typical) on
single mode fiber-optic cable as specified by ANSI SMF-PMD.
A-3
Download from Www.Somanuals.com. All Manuals Search And Download.
|