DVK Dryer Booster Fans
Booster Fan Activation Methods
Current Sensor
(DVK100B-C Kit)
This is the preferred method for activating a dryer booster fan. When a clothes dryer
is operating and drawing at least one amp of current, the current sensor automatical-
ly activates the DVK100B dryer booster fan.
Timer
(DVK100B-T Kit)
Timers are simple to install and are maintenance free. Simply setting the fan timer to
the same period as the dryer timer activates the DVK100B dryer booster fan.
Pressure Switch
(DVK100B-P Kit)
The pressure switch is designed to be mounted in the duct between the fan and the
dryer. When it senses dryer airflow, the switch activates the DVK100B dryer booster
fan.
Pressure Switch - Mounted
(DVK100B-PM Kit)
The pre-mounted pressure switch simplifies installation. Utilizing the components
found in the DVK100B-P kit, the pressure switch is pre-wired and factory mounted to
the DVK100B dryer booster fan.
Note:
Each of the above booster fan activation methods may be purchased as a
separate accessory item.
Available Accessories
A full range of accessories is available to suit each application.
Lint Trap
Mounting Clamps
Wall Caps
Roof Caps
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Tips
RC100 Roof Cap
• DVK100B fans should be mounted at least 15 linear feet from dryer.
• Each 90-degree elbow is equivalent to 5 linear feet of duct.
• DVK100B fans are designed to vent up to 110 feet of 4-inch rigid duct.
Helpful Hint
s
An LT100 Lint Trap may be installed between the dryer and the boost-
er fan to reduce lint build-up and maintenance on the fan.
DVK Kit
Performance Data
CUBIC FEET PER MINUTE
1
1
3
1
3
1
1
MODEL 0”SP /8”SP /4”SP /8”SP
/2”SP
/4”SP 1”SP 1 /4”SP 1 /2”SP
DVK100B 152 146 139 131
124
106
82
66
33
LT100 Lint Trap
Dimensional Data
D
d
a
B
WT
MODEL WATTS AMPS RPM dBA
DVK100B 85 0.69 2400 54
(in.)
(in.)
(in.)
(in.)
(lbs)
9.5
3.9
1.0
8.3
6.5
Additional CFM Products
EXT
AXC
Externaal Mounnt Duct Fans
In-Line Duct Fans
CX
AeroFan
EXT
AXC
Air Purification Systems
Superior Bathroom Fans
External Mount Duct Fans
In-Line Duct Fans
Distributed By:
Continental Fan Manufacturing Inc.
203 Eggert Road
Aeroflo Inc.
12–205 Matheson Blvd. East
Buffalo, NY 14215
Mississauga, Ontario, Canada L4Z 3E3
Tel: 905-890-6192 Toll: 800-779-4021
Fax: 905-890-6193
Tel: 716-842-0670 Toll: 800-779-4021
Fax: 716-842-0611
Download from Www.Somanuals.com. All Manuals Search And Download.
|