CDA Ventilation Hood CIGE9 User Manual

CIGE9 Extractors  
Manual for Installation, Use and Maintenance  
Customer Care Department • The  
Group Ltd. • Harby Road • Langar • Nottinghamshire • NG13 9HY  
T : 01949 862 012 F : 01949 862 003 E : [email protected] W : www.cda.eu  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using your Extractor  
For best performance, you should switch on the extractor 15 minutes before starting to cook and leave it to run for  
approximately 15 minutes after the end of cooking.  
A - Light switch  
B - Power indicator light  
C - Power switch  
A
B
C
A1 A2  
C1 C3  
C2 C4  
Fig. 1  
To switch the extractor light on or off  
Slide the light switch to position A1 for off, or A2 for on.  
To switch on the extractor, or change the motor speed  
Slide the power switch to the position required dependent on the speed you require.  
To switch the extractor off  
Slide the power switch to position C1 for off.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Care and Maintenance  
IMPORTANT: DO NOT PERFORM MAINTENANCE  
OR CLEANING OF THE EXTRACTOR WITHOUT FIRST  
SWITCHING OFF THE ELECTRICITY SUPPLY.  
Cleaning  
You should use a non-abrasive cleaner. Any abrasive cleaner  
(including Cif) will scratch the surface and could erase the  
control panel markings.  
You can clean you extractor effectively by simply using a  
dilute solution of water and mild detergent and drying to a  
shine with a clean cloth, for example the CDA E-Cloth.  
Fig. 2  
Cleaning the grease filter  
The grease filters should be kept clean to minimise the risk  
of fire.  
At least once a month you should remove and clean the  
grease filters with hot soapy water. You can also wash the  
grease filters in a dishwasher, ensuring that you place it in an  
upright position to prevent damage from other items in the  
dishwasher. After rinsing and drying, replace the filters.  
To remove the grease filters, pull open the handle on the  
grease filter.. It will release at the handle side. Then lower the  
grease filter to remove it completely. To replace the grease  
filter, repeat the steps in reverse.  
Please note:  
Cleaning the grease filters in the dishwasher may lead to  
discolouration. This is normal and does not constitute a fault  
with the appliance.  
Changing the charcoal filter (re-circulating only)  
To ensure best performance of your extractor, you should  
replace the charcoal filters every four to six months,  
depending on use.  
To attach a new charcoal filter, rst remove the grease filters  
as described above. Then offer up the charcoal filter to the  
side of the motor as shown in figure 2 and turn it clockwise  
until it locks into place. Repeat with the other charcoal filter  
on the other side of the motor. Then replace the grease  
filters and cover panels.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Changing the Light  
IMPORTANT: DO NOT PERFORM MAINTENANCE OR CLEANING OF THE EXTRACTOR WITHOUT FIRST  
SWITCHING OFF THE ELECTRICITY SUPPLY.  
DO NOT CHANGE THE LIGHT BULB IMMEDIATELY AFTER USE AS THE BULB WILL BE HOT. ALLOW IT TO  
COOL BEFORE REMOVING IT.  
1. Remove the grease filters as described above.  
2. Remove the faulty light bulb and replace with a light bulb no more powerful than that specified on the  
rating plate.  
3. Replace the grease filters.  
Do not touch bulbs or adjacent areas during or straight after prolonged use of the lights.  
The light is designed for use during cooking and not for general room illumination. Extended use of the light can  
reduce the lifespan of the bulb.  
Bulb replacement is not covered by the guarantee.  
Only use bulbs recommended for your extractor. Do not fit bulbs of a higher power rating. Bulbs of a lower power  
rating may be adequate for use, generally last longer, and use less energy.  
Spare bulbs are available from CDA Customer Care or from your local DIY shop.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mains Electricity Connection  
THIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY BY A COMPETENT PERSON, USING FIXED  
WIRING VIA A DOUBLE POLE SWITCHED FUSED SPUR OUTLET AND PROTECTED BY A 3A FUSE.  
We recommend that the appliance is connected by a qualified electrician, who is a member of the N.I.C.E.I.C. and who will  
comply with the I.E.E. and local regulations.  
DOUBLE POLE SWITCHED  
The wires in the mains lead of this appliance are coloured in accordance with the  
FUSED SPUR OUTLET  
following code:  
BLUE = NEUTRAL, BROWN = LIVE.  
As the colours of the wires in the mains lead for the appliance may not correspond  
with the coloured markings identifying the terminals connecting to the fused spur,  
proceed as follows:  
The wire which is coloured blue must be connected to the terminal marked N  
(Neutral), or coloured black.  
The wire which is coloured brown must be connected to the terminal marked  
L (Live), or coloured red.  
USE A 3 AMP FUSE  
NOTE: USE A 3A FUSE  
Assembly and electrical connection should be carried out by competent personnel.  
When installing this product we recommend you seek the help of another individual.  
IMPORTANT: THIS APPLIANCE IS A CLASS II APPLIANCE (DOUBLE INSULATED) AND IS NOT INTENDED TO  
BE EARTHED. DO NOT FIT AN EARTH LEAD TO THIS EXTRACTOR.  
Do not mount the isolation switch behind the chimney section. It is a requirement that you must be able to isolate the  
extractor from the mains electrical supply after installation.  
This appliance is intended to be connected to the mains electrical supply by means of an isolation switch and fused spur  
and is intended to be protected by a 3A fuse. The use of a 13A fuse can cause damage to the internal wiring in the event  
of a fault, and may also invalidate the warranty.  
Electrical Information  
Mains electrical voltage: 230 – 240Vac.  
Total rated power consumption: 230W.  
Troubleshooting  
If your extractor is not working:  
1. Check that the mains supply has not been switched off.  
2. Check that the fuse in the spur has not blown.  
Contact CDA Customer Care  
A : Customer Care Department, The CDA Group Ltd, Harby Road, Langar, Nottinghamshire, NG13 9HY  
T : 01949 862 012 F : 01949 862 003 E : [email protected] W : www.cda.eu  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
IMPORTANT:  
The extractor is intended to be mounted directly to  
the ceiling using fixings appropriate for the ceiling.  
Ensure that there is adequate ceiling strength and  
supports at the fixing points; if in doubt, consult a  
joiner or electrician.  
540 – 820mm  
Mounting Your Extractor:  
When the extractor is to be installed above an electric hob,  
the minimum distance between the hob and extractor must  
exceed 600mm (650mm is recommended)  
When the extractor is to be mounted above a gas hob, the  
minimum distance between the hob and the extractor must  
exceed 700mm (750mm is recommended)  
Electric: 650mm recommended  
Gas: 750mm recommended  
If the instructions provided with your hob state that the  
required distance between the hob and extractor must be  
greater than 700mm, then that distance should be observed;  
this is a legal requirement and may lead to your hob being  
disconnected from the gas supply and the installation being  
reported to RIDDOR (The height should be measured from  
the top of the burners.  
Fig. 3  
IN THE ABSENCE OF ANY SUPPLIED INSTRUCTIONS  
WITH YOUR GAS HOB, THE MINIMUM DISTANCE  
BETWEEN THE HOB AND EXTRACTOR MUST BE AT  
LEAST 760mm  
The width of any hob must not be greater than the width of  
the extractor installed above it.  
Ducting and Ventilation  
For best performance and lowest noise output, we  
recommend the use of 120mm ducting. You can also use  
100mm ducting but this will reduce performance.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
To x your extractor to the ceiling, proceed as follows  
1. Mark the fixing positions of the wall plugs that will be  
used to secure your extractor to the ceiling, as shown in  
fig. 4  
191  
2. Drill 4 holes and insert the wallplugs, ensuring that they  
are suitable for use with your ceiling. If the extractor is to  
be fixed directly to ceiling joists then wall plugs may not  
be required.  
203  
Fig.4  
3. Fit the vent adaptor (G) to the body of the extractor,  
using the 2 self-tapping screws.  
E
4. Calculate the height of the chimney section as follows  
Length of support section = Ceiling height – (285 + H + Hob  
height above floor)  
D
B
H= 600 min for electric hobs (650mm recommended)  
H=700mm minimum for gas hobs (750mm recommended)  
5. Fix the 2 support sections(A) at the required length using  
4 self-tapping screws. Note that if the exact height  
cannot be set, use the frame position corresponding to  
the next highest one.  
6. Fix the support sections to the main motor body using 4  
machine screws.  
I
7. Slide the two decorative sections over the frame sections.  
A
8. If your extractor is to be used as a recirculation device, fit  
the deflector panel (I) onto the top of the frame section,  
as shown.  
G
9. With assistance, mount the entire assembly to the ceiling  
using appropriate fixing screws. Once this operation  
has been completed, the extractor is fully supported by  
the ceiling fixings.  
10. Mount the top chimney section (D) to the top of the  
frame section using 2 screws (E)  
11. If using the extractor to extract air outside, connect the  
duct pipe to the vent adaptor (G), ensuring a good seal  
to prevent air escaping. (The lower decorative section  
(B) can be raised and tape to allow access to the outlet  
adapter (G))  
Fig.5  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To contact our Customer Care Department, or for Service,  
please contact us on the details below.  
Customer Care Department • The  
Group Ltd. • Harby Road • Langar • Nottinghamshire • NG13 9HY  
T : 01949 862 012 F : 01949 862 003 E : [email protected] W : www.cda.eu  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Black Decker Automobile Accessories SM511 User Manual
BlueAnt Wireless Bluetooth Headset 3 User Manual
Bosch Power Tools Grinder GWS 6 100 E User Manual
Briggs Stratton Lawn Mower 21C200 User Manual
Broan Ventilation Hood RM523604 User Manual
Campbell Hausfeld Network Card SDM CD16AC User Manual
Canon Camera Lens EF800MM User Manual
Casio Calculator FX 10 PLUS User Manual
Casio Clock GQ 500 User Manual
Cisco Systems Computer Hardware WMP600N User Manual