Bryant Furnace 369AAN User Manual

Oil Furnace  
Model 369AAN  
USER’S  
INFORMATION  
MANUAL FOR  
THE  
OPERATION  
AND  
MAINTENANCE  
OF YOUR NEW  
OIL-FIRED  
FURNACE  
NOTE TO  
INSTALLER:  
This manual  
must be  
left with the  
equipment user.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FURNACE COMPONENTS  
6
7
8
9
5
4
3
2
1
10  
11  
12  
SEE NOTES: 13, 14  
Left side, right side, or bottom.  
2
1
2
3
4
5
Heavy-duty blower circulates air across the heat  
exchanger to transfer heat into the home.  
8
Reversible door provides easy access to burner  
and controls.  
9
Stainless steel combustion chamber/primary  
heat exchanger.  
High-performance oil burner.  
10  
Manual switch to allow user control of constant  
low-speed blower operation.  
Unique silencer system reduces combustion  
noise.  
11  
Adjustable electronic fan timer control (inside)  
with low-voltage electrical terminal strip for  
easy connection of thermostat, cooling control,  
electronic air cleaner, and humidifier.  
Heat exchanger designed and shaped to effi-  
ciently transfer heat from furnace into the home.  
Fully insulated internal walls to minimize heat  
loss.  
12  
13  
14  
Access door to air filters and blower.  
Air filter (field-supplied).  
Return-air plenum.  
6
7
Supply-air plenum.  
High limit control to prevent overtemperature  
operation.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Immediately call a qualified ser- minor personal injury or product  
vice technician to inspect the fur- and property damage.  
nace and to replace any part of the  
IMPORTANT FACTS  
Your furnace must have adequate  
airflow for efficient combustion  
and safe ventilation. Do not  
enclose it in an airtight room or  
“seal” it behind solid doors.  
!
WARNING  
control system, electrical compo-  
nents, and any oil control which  
has been under water.  
For use with grade 2 Fuel Oil  
maximum. Do not use Gaso-  
line, Crankcase Oil, or any Oil  
containing Gasoline! Failure  
to follow this warning could  
lead to sooting, fire, explo-  
sion, and/or severe bodily  
harm.  
NOTE: The qualified installer or  
agency must use only factory-  
authorized replacement parts, kits,  
and accessories when servicing  
this product.  
To minimize the possibility of  
serious personal injury, fire, fur-  
nace damage, or improper opera-  
tion, carefully follow  
safety rules:  
these  
The furnace burner control has a  
safety device which must be man-  
ually reset. If the furnace is left  
unattended for an extended period  
of time, have it checked periodi-  
cally for proper operation. This  
precaution will prevent problems  
associated with no heat, such as  
frozen water pipes, etc.  
!
CAUTION  
FORYOUR SAFETY  
Never burn garbage or paper  
in the heating system and  
never leave rags, paper, or  
any flammable items around  
the unit.  
Do not store or use gaso-  
line or other flammable  
vapors and liquids in the  
vicinity of this or any oth-  
er appliance.  
STARTING YOUR  
FURNACE  
This appliance is equipped with an  
ignitiondevicewhichautomatically  
lights the burner each time the ther-  
mostat starts your furnace. Follow  
these important safeguards:  
SAFETY  
CONSIDERATIONS  
Installing and servicing of heating  
equipment can be hazardous due to  
oil and electrical components.  
Only trained and qualified person-  
nel should install, repair, or service  
heating equipment.  
!
CAUTION  
This furnace is equipped with  
a constant type primary igni-  
tion system. DO NOT AT-  
TEMPT TO LIGHT WITH A  
MATCH.  
Untrained personnel can perform  
basic maintenance functions such  
as cleaning and replacing air filters.  
All other operations must be per-  
formed by trained service person-  
nel. Observe safety precautions in  
this manual, on tags, and on labels  
3
• Do not cover the furnace, store  
trash or debris near it, or in any way  
block the flow of fresh air to the  
unit.  
• Combustion air must be clean and attached to the furnace and other  
not contaminated with chlorine or safety precautions that may apply.  
fluorine. These compounds are  
Recognize safety information.  
present in many products around  
This is the safety-alert symbol ! .  
the home, such as: water softener  
When you see this symbol on the  
salts, laundry bleaches, detergents,  
furnace and in instructions or man-  
adhesives, paints, varnishes, paint  
uals, be alert to the potential for  
4
strippers, waxes, and plastics.  
personal injury.  
!
DANGER  
Make sure the combustion air for  
Understand the signal words —  
HIGH VOLTAGE AT IGNI-  
TOR. Severe electrical  
shock, personal injury, or  
death could result.  
your furnace does not contain any  
DANGER, WARNING, and CAU-  
of these compounds. During re-  
TION. These words are used with  
modeling be sure the combustion  
the safety-alert symbol. DANGER  
air is fresh and uncontaminated. If  
identifies the most serious hazards  
air with vapors of these compounds  
• If a suspected malfunction occurs  
with your oil control system, such as  
the burner not lighting when it  
should, refer to the “Shutting Down  
Your Furnace” section and call your  
dealer as soon as possible.  
which will result in severe personal  
injury or death. WARNING signi-  
fies hazards which could result in  
personal injury or death. CAU-  
is burned in your furnace, the heat  
exchangers and metal vent system  
may deteriorate.  
NOTE: Do not use this furnace if TION is used to identify unsafe  
any part has been under water. practices which would result in  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHECK AIR FILTER: Before  
attempting to start your furnace, be  
sure the furnace air filter is clean  
and in place. See “Performing Rou-  
tine Maintenance” section in this  
manual. Then proceed as follows:  
When room temperature drops  
below temperature selected on  
the thermostat, the furnace will  
be switched on automatically.  
When room temperature reaches  
the degree selected on the ther-  
mostat, the furnace will be  
switched off automatically.  
STEPS FOR STARTING  
YOUR FURNACE  
Some thermostats have a FAN  
mode with 2 selections, AUTO  
and ON. When thermostat is set  
to AUTO, the furnace blower  
cycles on and off, controlled by  
the thermostat. In ON mode, the  
furnace blower runs continu-  
ously. This keeps the tempera-  
ture level in your home more  
evenly balanced. It also contin-  
uously filters indoor air.  
7
1. Open all warm air registers and  
make sure that all return-air  
grills are unobstructed.  
7. Check all connections to ensure  
there are no leaks.  
2. If a humidifier is installed with  
your system, open water supply  
valve.  
8. Set room thermostat to a tem-  
perature slightly above room  
temperature. This will auto-  
matically signal the furnace to  
start.  
3. Make sure blower access door is  
secured in place.  
9. When the thermostat calls for NOTE: Constant low-speed blower  
heat, power from the trans- operation can also be achieved by  
former energizes the fan control turning on the constant blower  
board. The fan control energizes rocker switch located on side of  
the ignition control. The igni- control box. Regardless of room  
tion control will automatically thermostat setting, blower will run  
4. Set your room thermostat to  
lowest temperature setting.  
(See Fig. 5.)  
®
light the burner.  
continuously in low speed to pro-  
vide constant air circulation. If  
constant blower rocker switch is  
turned off, room thermostat will  
control blower operation.  
The electronic fan control auto-  
matically turns on the blower  
after 60 sec. Fan on control is  
not adjustable. The air moved  
over the heat exchanger by the  
blower is warmed and passes  
through the ducts to the room  
registers.  
SHUTTING DOWN  
YOUR FURNACE  
Should you need to shut down your  
furnace for service or maintenance,  
you will need to turn the furnace  
off. The following procedures must  
be followed:  
5
5. Turn on electric power to  
furnace. (See Fig. 6.)  
This unit is equipped with con-  
tinuous ignition control. If the  
main burner does not ignite  
within 30 sec from the call for  
heat, the control will lock out.  
The red button on top of the  
control must be depressed for 3  
sec in order to reset the control.  
The control CANNOT be reset  
from the room thermostat.  
1. Set thermostat to lowest setting.  
(See Fig. 8.)  
®
10. Set your thermostat to the tem-  
perature that satisfies your com-  
for requirements. SUGGES-  
TION: Setting the thermostat  
back a few degrees and compen-  
sating for the difference with  
warmer clothing can make a big  
difference in your fuel consump-  
tion on extremely cold days. The  
few degrees at the top of your  
thermostat “comfort level” are  
the most costly degrees to obtain.  
6
6. Open oil supply valve.  
(See Fig. 7.)  
8
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
To inspect, clean, and/or replace air  
filter, follow these steps:  
2. Turn off all electrical power to  
the furnace. (See Fig. 9.)  
!
WARNING  
Turn off all electrical power to  
furnace before performing  
any maintenance or service  
on unit. Failure to take this  
precaution may result in per-  
sonal injury due to electrical  
shock.  
1. Turn off electrical supply to fur-  
nace. (See Fig. 11.)  
2. Remove filter from external fil-  
ter rack.  
3. Inspect filter. If torn, replace it.  
NOTE: If filter has been replaced  
with an electronic air cleaner  
(EAC), refer to the EAC Owner’s  
Manual for maintenance informa-  
tion.  
9
3. Close oil supply valve.  
(See Fig. 10).  
5. If filter is dirty, it must be re-  
placed. If your furnace air filter  
needs to be replaced, be sure to  
use the same size and type of fil-  
ter that was originally supplied.  
Use furnace filter table for filter  
size and filter rack flange dimen-  
sions for return air duct.  
11  
FURNACE AIR FILTERTABLE  
!
CAUTION  
FLANGE  
OPENING  
SIZE  
Although special care has  
been taken to minimize sharp  
edges, be extremely careful  
when handling parts or  
reaching into the furnace.  
FILTER  
SIZE  
FILTER  
TYPE  
(IN.)  
(IN.)  
15 X 24  
17 X 30  
16 X 24–25 X 1 Disposable  
18 X 30 X 1 Disposable  
10  
If you have replaced a disposable  
filter with a permanent washable  
filter, it may be cleaned if it is dirty.  
Wash filter in a sink, bathtub, or  
outside with a garden hose. Always  
use cold tap water. A mild liquid  
detergent may be used if necessary.  
Spray water through filter in the  
opposite direction of airflow.  
Allow filter to dry.  
FILTERING OUT  
TROUBLE  
4. If applicable, turn off water sup-  
ply to humidifier.  
Dirty air filters will cause a loss of  
airflow in your duct system. When  
excessive loss of airflow occurs,  
the furnace may cycle on its safety  
controls. If this condition is left  
unattended, the furnace will even-  
tually lock out. It is recommended  
that furnace air filters be checked  
every 3 or 4 weeks and cleaned or  
replaced as necessary.  
5. If furnace blower will be neces-  
sary for cooling system, remem-  
ber to turn electric power back  
on when needed for air condi-  
tioning.  
6. If furnace is being shut down be-  
cause of a malfunction, call your  
dealer as soon as possible.  
6. Re-install clean air filter.  
7. Turn on electrical supply to  
furnace.  
ALWAYS KEEP MAIN OIL  
VALVE TURNED OFF IF  
BURNER IS SHUT DOWN FOR  
AN EXTENDED PERIOD OF  
TIME.  
!
CAUTION  
A CHECK-UP  
CHECKLIST  
Never operate your furnace  
without the air filters in place.  
Doing so may damage the  
furnace blower motor. An ac-  
cumulation of dust and lint  
on internal parts of your fur-  
nace can cause a loss of effi-  
ciency.  
Your furnace represents an impor-  
tant investment in your family’s  
comfort and your home’s value. To  
keep it performing properly and as  
a preventative to future problems,  
have a trained service specialist  
give your furnace a professional  
check-up annually. The following  
checklist can be used as a guideline  
to proper service:  
PERFORMING  
ROUTINE  
MAINTENANCE  
With proper maintenance and care,  
your furnace will operate economi-  
cally and dependably. Instructions  
for basic maintenance follow. How-  
ever, before beginning maintenance,  
follow these safety precautions:  
The air filter is installed in an ex-  
ternal filter rack which is provided  
a standard equipment with furnace.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
• Check flue and secondary tube pas- tions, and components for loose con- IF FURNACE FAILS TO  
sage ways including chimney — nections.  
clean if necessary.  
OPERATE:  
Follow this checklist step by step,  
advancing to the next step only if  
furnace fails to start.  
• Check thermostat for proper tem-  
perature. Is thermostat set above  
room temperature?  
• Is thermostat set on HEAT?  
• Check fuses and circuit breakers.  
Is electrical supply on?  
• Examine the physical support of  
• Change oil filter.  
• Change nozzle.  
• Check and adjust combustion and  
draft.  
• Inspect all vent piping inside struc-  
ture for deterioration and vent termi-  
nations outside the structure for  
blockage.  
the furnace. Support should be  
sound with no cracks, sagging, gaps,  
etc. around the base.  
• Check furnace for any obvious  
signs of deterioration.  
BEFOREYOU REQUEST  
A SERVICE CALL  
• Check oil pipes leading to and  
inside of your furnace for leaks.  
• Is valve in oil supply pipe in open  
position?  
If your furnace is not operating or  
not performing properly, you may  
save the expense of a service call  
by checking a few things yourself  
before calling for service.  
• Inspect and clean the blower motor  
and wheel.  
• Inspect and change or clean air fil-  
ter if necessary.  
• Inspect all supply- and return-air  
ducts for obstructions, air leaks, and  
insulation. Remedy any problem  
when necessary.  
• Inspect the return-air duct connec-  
tions at the furnace to ensure it is  
physically sound, sealed to the fur-  
nace casing, and terminates outside  
the space containing the furnace.  
• Is the ignition control on the burn-  
er not in lockout? The red button on  
top of the control must be depressed  
for 3 sec in order to reset the control.  
• Check for obstructions around the  
vent termination.  
If furnace still fails to operate, call  
your service representative. For your  
convenience, record furnace product  
and serial numbers on page 2.  
Should you ever require service, you  
will have ready access to the infor-  
FOR INSUFFICIENT AIRFLOW:  
• Check for dirty air filters.  
• Check for blocked return-air or  
supply-air grilles throughout your  
home. Ensure they are open and  
unobstructed.  
If problem still exists, call your mation needed by your service rep-  
dealer for service.  
• Inspect electrical wiring, connec-  
resentative.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cancels: OM16-7  
OM16-9  
12-97  
© 1997 Bryant Heating & Cooling Systems, 7310 W. Morris St. Indpls, IN 46231  
Printed in U.S.A.  
Catalog No. 5336-904  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  

Bionaire Air Cleaner BAP4010 User Manual
Black Decker Coffeemaker DCM2160B User Manual
Body Solid Home Gym FID 46 User Manual
Bowflex Home Gym BDS 220 User Manual
Brother All in One Printer DCP User Manual
Bushnell Binoculars 11 8323 User Manual
Canon Network Cables MG6120 User Manual
Canon Photo Scanner CP910 User Manual
Channel Vision Speaker System C 1001 User Manual
Char Broil Outdoor Cart 463248208 User Manual