Bravo View Water Pump B409 User Manual

INSTALLATION INSTRUCTIONS  
FOR B409 DOUBLEWALL TANK SUMP  
WITH REINFORCED BOTTOM  
S. Bravo Systems, Inc.  
2929 Vail Ave. - Commerce, CA 90040  
(323) 888-4133 - FAX: (323) 888-4123  
Written by: Jonathan Smith  
ii-B409-DW-10A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BEFORE PENETRATING FIBERGLASS  
WALLS ENSURE THAT EACH DOUBLE WALL  
FIBERGLASS SUMP IS HOLDING VACUUM  
It is REQUIRED to visually check the Vacuum gauge on each  
and every Bravo Systems Double Wall product and write on its  
FAX report Vacuum level, name of observer, and date for  
every DoubleWall Sump.  
WARRANTY IS VOID:  
IF ANY OF THE FOLLOWING OCCUR  
A) There is a failure to comply with the Required written report guidelines as stated above.  
B) Double Wall Products are DOUBLE-STACKED, stored or shipped in a negligent way.  
C)Any packaging or wrapping materials are removed before the item reaches It’s destination.  
D) Double Wall Sump Products, Failure to call Bravo Systems If Vacuum level on product is  
less than 12” HG (Vacuum) (323) 888-4133, refer to sump for further details.  
E) Double Wall Sump Products are tested per the SB989 Testing procedures. The interior  
of these sumps must NOT be filled with liquid to any level.  
F) Double Wall Sumps are filled with an unapproved interstitial fluid, or if adhesives or  
sealants are used that are not Bravo-approved.  
If there is any indication or suspect damage, you must mark the freight paperwork  
“Suspect Freight Damage” as directed by your Contractor Warranty sheet.  
3
ii-B409-DW-10A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EQUIPMENT DRY-FIT  
- BEFORE INSTALLING PENETRATION FITTINGS  
- BEFORE CUTTING OPEN SUMP INTERSTICE  
DRY-FIT YOUR SUMP PIECES AND  
INTERNAL EQUIPMENT.  
PLAN YOUR INSTALLATION AND MAKE  
SURE EVERYTHING FITS, AND WILL FIT  
LATER DURING INSTALLATION.  
Recommended Tools  
(NOT PROVIDED)  
HYDROSTATIC ONLY!!  
MANOMETER KIT (PER SUMP)  
Power/air Sanders. Acetone to clean up  
tools/applicators. Power Cutting Tools.  
- Interstitial fluid  
- Standard Manometer  
- Manometer Bracket  
- Factory-Installed  
Nylon tubing  
TOTAL HEIGHT  
4’ = 5 gal  
5’ = 6 gal  
T-F-33-SAND-KIT  
5/8” sanding disc backs and  
centralizers for all Bravo  
Systems Fittings  
6’ = 7 gal  
7’ = 8 gal  
w/20”Hg Vacuum  
on interstice  
SVA-BARB  
per sump  
per site  
w/Combination  
Pressure/Vacuum  
Gauge  
VAC-KIT-D-AB  
4
ii-B409-DW-10A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A - INSTALLING AND SECURING YOUR B409  
BEFORE INSTALLING PENETRATION FITTINGS  
ENSURE THAT THE SUMP BODY IS HOLDING VACUUM.  
If the gauge is Below 12 inches of mercury (Hg/Vacuum), then pressurize the  
sump interstice to 4 PSI and submerge the gauge and tubing assemblies.  
Soap test the test tubing fittings on the walls. If an air leak is found, contact  
the factory. If no leak at the tubing is found, soap test the rest of the sump  
surface starting with the exterior. Visually inspect for damage. If the leak is found,  
patch per repair directions in this manual.  
If the gauge is AT OR ABOVE 12 INCHES OF MERCURY, proceed to Step A.1  
A.1 - Visually inspect the parts provided by Bravo Systems for In-transit damage and/or missing  
parts. Continue to keep the Sump clean of debris throughout your installation process.  
A.2 - Set your B409 Piping Sump where it must be per site plans. Secure the Sump to avoid  
movement while penetrating.  
A.3 - Mark where you will penetrate the Base/Tank Collar wall.  
A.4 - Install Penetration Fittings per their respective Installation Instructions. You must NOT  
disturb the penetration fittings while the sealant/adhesive is drying. Allow for the maximum cure time  
as recommended by the manufacturer of the fittings before pressurizing & soaping to test for leaks.  
DO NOT FILL DOUBLE WALL PENETRATION FITTINGS  
WITH FOREIGN MATERIALS, SEALANTS or ADHESIVES.  
While Fiberglassing, curing, or sitting overnight, keep the  
SVA-BARB in place. This will relieve pressure on the Interstice  
while the sumps are heating up or cooling off.  
SAVE THESE PIECES, DO NOT LOSE THEM! Remove the SVA-BARB when ready to test.  
Gauge  
Assembly  
CAP  
SVA-BARB  
5
ii-B409-DW-10A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
B - MANDATORY AIR  
INTEGRITY TEST  
B.1 - Use test assembly and pressure sump to no more  
than 4 PSI. Close off with ball valve and resume other work.  
Allow 1 Hour before recording pressure.  
FIELD AIR INTEGRITY INSPECTION TEST : Hold pressure for a  
BRAVO  
QUALITY  
minimum of 1 hour for a Field Integrity Inspection Test. The Tank Sump PASSES  
the integrity test if the Sump shows NO signs of continuous pressure decay.  
STANDARD  
IF TEST PASSES - CONTINUE ON TO THE HYDROSTATIC FILL & INTEGRITY TEST.  
B.2 - IF ANY LEAKS ARE FOUND!!  
Look at edges and corners for pinhole leaks. For large leaks, consult factory.  
A: Locate leak point(s) and mark with marker so you can locate it / monitor it.  
B: Repair or reinstall doublewall penetration fittings according to your doublewall penetration  
fitting manufacturers’ Installation / Maintenance Instructions.  
C: Abrade a 2” diameter area centered on the leak point until natural resin/fiberglass material  
can be seen. Dust with shop brush or compressed air and do not use shop towels or  
acetone on the abraded area(s). Then apply a 3-layer strip of 2” x 2” resin-saturated  
fiberglass mat squarely on the abraded area.  
D: Roll out any air bubbles with chamfer roller. Let cure.  
E: After cure, knock down fiberglass hairs, and apply another flow coat of  
resin only. Apply any extra resin to repaired leak point(s) while still wet.  
Let cure for a minimum of 4 hours @ or above 75° F.  
FOR HYDROSTATIC MONITORING - PROCEED TO SECTION C.  
FOR CONTINUOUS VACUUM MONITORING - The B409 DoubleWall  
Solid Sump w/Bottom cannot exceed 16” of Mercury. (Vacuum)  
Connect the SVA-BARB to  
Follow your vacuum system manufacturer’s installation instructions  
your factory-installed gauge  
to install, seal, and monitor the doublewall system with vacuum.  
for vacuum monitoring  
Continue to Section F.  
Ensure that the fittings that are being used with the  
Vacuum Monitored System can withstand the amount  
of Vacuum your Monitoring System will generate.  
6
ii-B409-DW-10A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
C - VACUUM / HYDROSTATIC FILLING  
FIELD AIR INTEGRITY INSPECTION TEST :  
YOUR PRODUCT WARRANTY WILL BE VOID IF YOU DO NOT Hold pressure  
for a minimum of 1 hour for a Field Integrity Inspection Test. After passing  
the pressure test, it is HIGHLY RECOMMENDED that the 4 PSI is  
maintained for as long as possible, up until the time of backfill.  
YOUR PRODUCT WARRANTY WILL BE REVOKED IF YOU  
CHOOSE TO SKIP THE AIR INTEGRITY TEST OUTLINED IN YOUR  
COPY OF YOUR PRODUCT INSTALLATION INSTRUCTIONS. YOU MUST COMPLETE THE  
PRESSURE TEST PRIOR TO HYDROSTATIC FILLING OF THE SUMPS.  
The Bravo Double Wall product’s ship from the factory with a combination gauge factory- installed  
and held under 20” of mercury / vacuum.  
C.1 - After passing the Field Air Integrity Test per the Installation Instructions and there are no  
signs of leaks, you must cut the permanently affixed pipe plug from the tubing connected to the side  
wall. This is NOT the tubing with the gauge connected to it.  
C.2 - Connect (newly cut) open end of tubing to barb-and-ball-valve assembly. (sold seperately)  
A 36” length of clear tubing is factory installed to the barb-and-ball-valve assembly.  
Barb & Ball Valve  
Assembly  
After the penetration  
fittings have been  
Cut Plug end off  
from tubing  
installed, the vacuum has  
been lost. Pressure/soap  
tests should have been  
conducted prior to filling  
the sumps with liquid.  
Connect  
Assembly to  
tubing  
You must cut off the barbed  
plug and connect the  
provided Barb & Ball Valve  
Assembly. Close off the ball  
valve and prepare the  
Venturi Vacuum Generator  
and air supply to be used to  
fill Sump with liquid.  
7
ii-B409-DW-10A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
C.3 - Close off ball valve completely and  
prime the open ended 36” length of clear tubing  
with provided Interstitial Fluid. Use a liquid funnel.  
Filling Bravo Systems Double  
Wall Products with Brine  
(saline) solution will void the product  
warranty. You must use only Bravo-Supplied  
Interstitial Fluid, part # IMF-1GAL  
Barb &  
Ball Valve  
Assembly  
Venturi Vacuum Generator  
After liquid fill, Conduct the  
Advanced Leak Detection  
Procedure, then Cut the ball  
valve assembly from its tubing  
and connect open end of tubing  
to Primary manometer. Also  
unthread the Gauge Assembly  
and use provided PVC threaded  
plug to close off open test port  
fitting.  
Bucket  
C.4 -After filling the tubing all the way to the ball valve, insert open end into your liquid source.  
(5 gallon bucket filled with fluid is recommended.)  
C.5 - When ready, pull vacuum using the Venturi Vacuum Assembly (sold seperately) to 20 Inches  
of mercury. Then SLOWLY open ball valve and allow Interstitial fluid to flow freely into the system at a  
rate of about 2 gallons a minute.  
...SLOWLY open ball valve...  
C.6 - STOP PULLING VACUUM WHEN THE LIQUID IS 2-3 INCHES FROM THE VERY TOP OF  
THE INTERSTITIAL SPACE / TEST PORT. This is easily visible while filling the DoubleWall Product.  
8
ii-B409-DW-10A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D) ADVANCED LEAK DETECTION  
PROCEDURE  
A Bravo Systems Exclusive detection method  
D.1 - Clear debris from the top open area of the DoubleWall Product and ensure that the  
interior walls are clean of debris and visible.  
D.2 - Apply Vacuum to the sealed interstitial space with the Venturi Vacuum Assembly, and  
generate 20”-30” of vacuum for a MINIMUM of Five [ 5 ] Minutes.  
CHECK WITH YOUR EQUIPMENT MANUFACTURERS  
INSTALLATION MANUALS FOR INSTALLATION  
GUIDELINES AND/OR EQUIPMENT LIMITS REGARDING  
VACUUM AND PRESSURE LEVELS.  
D.3 - As stated in your Instructions, the liquid level is deliberately not filled to the very top  
of the interstitial space. This pocket of air is necessary to visually check the topmost level of  
liquid all the way around the Sump for indication of a leak.  
D.4 - Visually inspect the interior walls for signs of trailing (very small) bubbles floating to  
the top of the liquid level within the interstitial space.  
These air bubbles are visible within the vertical and horizontal  
channels of the walls. For Tank Sumps look below the reducer.  
On the top hat reducer of a Tank Sump, any bubbles will burp  
consistently.  
PAY CLOSE AND SPECIAL ATTENTION TO FIELD-INSTALLED  
PENETRATION FITTINGS and FRP JOINTS ON TANK SUMPS.  
THESE ARE COMMON LEAK POINTS.  
Even though Bravo DoubleWall product corners and edges are thicker than the rest of the  
Containment sump, These areas recieve the most supceptable to physical damage by Installing  
Contractors. You would do well to be extremely careful with these DoubleWall products while storing,  
moving, transporting and Installing these critical environmental components.  
9
ii-B409-DW-10A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ALDP IN ACTION DIAGRAM  
F-32-TS-D  
Fitting  
Here a leak is visible while a strong vacuum is pulled on the  
Interstitial space, forcing tiny air bubbles into the interstitial  
space to travel upwards. These streams of bubbles are easily  
spotted and can be traced down to its leak point or area.  
PAY CLOSE AND SPECIAL ATTENTION TO FIELD-INSTALLED  
PENETRATION FITTINGS and FRP JOINTS ON TANK SUMPS.  
THESE ARE COMMON LEAK POINTS.  
Even though Bravo DoubleWall product corners and edges are thicker than the rest of the  
Containment sump, These areas recieve the most supceptable to physical damage by Installing  
Contractors. You would do well to be extremely careful with these DoubleWall products while storing,  
moving, transporting and Installing these critical environmental components.  
10  
ii-B409-DW-10A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E - CONNECTING TO MANOMETER  
E.1 -At this point, after the ALDP test, the interstice should still be holding vacuum. Maintain 20”  
of Vacuum and slowly open ball valve to let fluid into the interstice until it exits the venturi assembly.  
Visually check whether the fluid level reaches the top of the interstitial space.  
E.2 - Cut the barb & ball valve assembly free by cutting the tubing just below it and connect open  
end of tubing to the bottom of the primary Manometer.  
E.3 - Remove the Barb, Tubing & Combination gauge assembly from the test port fitting on the  
side of the sump. Install a threaded pipe plug into the open test port fitting and adjust Primary  
manometer bracket so the manometer is in a position clear of the sump cover.  
Remove Entire Gauge  
Assembly by backing  
off threaded barb fitting.  
Fig. E.7  
Sensor Cable  
Cut off barb  
& ball valve  
Cap assembly  
assembly.  
Install PVC Plug  
Connect Tubing to  
Primary Manometer  
Continuous Monitoring  
Interstitial & Leak  
Detection of Secondary  
Containment  
P-Traps OK since vacuum fill  
method leaves no room for air.  
E.4 - It is not uncommon for some interstitial fluid to be lost while connecting the tubing to the primary  
manometer. This is ok. Replace lost fluid by topping off manometer with interstitial fluid until the liquid level  
reaches just 2 inches below the top of manometer.  
E.5 - Hydrostatic Field Integrity Test - Mark the date and time of test and  
manometer level. Allow 1 hour to look for a change in level. No change in level or visible leaking means  
box passes test.  
E.6 - If interstitial test fluid changes its level more than 1/4”, visually look for any signs of leaking around  
fittings both interior and exterior to sump. Pay special attention to field installed fittings.  
E.7 - If interstitial monitoring is required, install a California Listed Hydrostatic Sensor (LG-113) using the  
sensor manufacturer’s fitting. Run sensor cable through the cap assembly (see Fig. E.7). Level sensor  
should be set to bottom of manometer. Follow your leak detector manufacturer’s installation instructions.  
Cover the manometer with cap and fasten with wire and lead crimp seal.  
11  
ii-B409-DW-10A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
G - Concrete and Backfill Guidelines.  
To ensure that no immediate or future damage is done to your Bravo Tank Sump Reducer  
components, make sure that your manhole skirt DOES NOT TOUCH OR REST ON THE TANK  
SUMP SHOULDER. The Manhole Skirt should be kept at minimum of 4” away from the tank sump  
shoulder. Follow the manhole manufacturers instructions for installing the manhole. Also follow other  
details provided by tank and/or engineering firm for tank driveway pad installation.  
Backfill your peagravel around the sump maintaining a minimum of 1’ foot all the way around (if your  
site backfill is not entirely peagravel) and 4” minimum distance from the top edge of sump reducer.  
When peagravel is in place, use a 3mil or thicker plastic sheet to cover the surface of the peagravel  
no less than 2 feet away from the sump reducer wall.  
Secure this plastic barrier to the EXTERIOR OF THE MANHOLE SKIRT using duct tape.  
This prevents concrete from seeping too far down  
into the peagravel.  
Minimum  
1” to 1-1/2”  
Distance  
4 inches  
between top  
of sump  
reducer and  
peagravel  
3mil+ Plastic Barrier  
taped to manhole skirt  
Manhole Cover  
Sump Cover  
Manhole skirt  
CONCRETE  
SLAB  
Manhole  
skirt min.  
4” away  
from Tank  
sump  
Min 1’ foot  
peagravel all  
around sump  
shoulder  
12  
ii-B409-DW-10A  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Black Box Switch Blackbox ServTray User Manual
Blizzard Entertainment Automobile Accessories 810SS User Manual
Bosch Appliances Saw 4100 User Manual
Brother Printer DCP 375CW User Manual
Cabletron Systems Switch SEHI100TX User Manual
Campbell Hausfeld Air Cleaner PA208503 User Manual
Carrier Air Compressor 07E User Manual
Casio Blood Pressure Monitor BP 1MY 1 User Manual
Celestron Heat Pump VMC30SB 1 User Manual
Chicago Electric Welder 8878 User Manual