VIP X1600 M4S
Encoder module
en Installation and Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600
Table of Contents | en
3
8
1.4
EU Directives
9
2.2
Installation and Operation
Overview of Functions
12
3.3
19
4.3
Connections
44
47
5.19
5.20
Advanced Mode: Encoder Profile
Advanced Mode: Audio (Audio Version Only)
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
4
de | Table of Contents
VIP X1600
98
6.8
Hardware Connections Between Video Servers
102
7.3
Repairs
104
106
8.2
8.3
General Malfunctions
Malfunctions with iSCSI Connections
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600
Table of Contents | en
5
8.9
109
Communication with Terminal Program
113
9.2
Protocols/Standards
11
Index
119
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
6
de | Table of Contents
VIP X1600
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Preface | en
7
1
Preface
1.1
About this Manual
This manual is intended for persons responsible for the installation and operation of the
VIP X1600 XF. International, national and any regional electrical engineering regulations must
be followed at all times. Relevant knowledge of network technology is required. The manual
describes the installation and operation of the unit.
1.2
Conventions in this Manual
In this manual, the following symbols and notations are used to draw attention to special
situations:
CAUTION!
This symbol indicates that failure to follow the safety instructions described may endanger
persons and cause damage to the unit or other equipment.
It is associated with immediate, direct hazards.
!
NOTICE!
This symbol refers to features and indicates tips and information for easier, more convenient
use of the unit.
1.3
Intended Use
The VIP X1600 XF network video server is intended for use with CCTV systems and serves to
transfer video and control signals via data networks (Ethernet LAN and Internet). The optional
modules for installation determine the range of functions. Encoder modules (senders) and
decoder modules (receivers) are available. The encoder modules each contain RAM memory
for short-term recording of connected cameras. Audio signals can also be transmitted with the
audio versions of the encoder modules. Various functions can be triggered automatically by
incorporating external alarm sensors. Other applications are not permitted.
In the event of questions concerning the use of the unit which are not answered in this
manual, please contact your sales partner or:
Bosch Security Systems
Robert-Koch-Straße 100
85521 Ottobrunn
Germany
www.boschsecurity.com
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
8
en | Preface
VIP X1600 M4S
1.4
EU Directives
The VIP X1600 XF network video server complies with the requirements of EU Directives 89/
336 (Electromagnetic Compatibility) and 73/23, amended by 93/68 (Low Voltage Directive).
1.5
Rating Plate
For exact identification, the model name and serial number are inscribed on the rating plate
on the bottom of the VIP X1600 XF base and on the rating plates on the circuit boards of the
modules. Please make a note of this information before installation, if necessary, so as to have
it to hand in case of questions or when ordering spare parts.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Safety Information | en
9
2
Safety Information
2.1
Electric Shock Hazard
–
Always install a module in the appropriate VIP X1600 XF base housing only.
–
If a fault occurs, disconnect the VIP X1600 XF from the power supply and from all other
units.
–
–
Install the power supply and the unit only in a dry, weather-protected location.
If safe operation of the unit cannot be ensured, remove it from service and secure it to
prevent unauthorized operation. In such cases, have the unit checked by Bosch Security
Systems.
Safe operation is no longer possible in the following cases:
–
–
–
–
–
–
if there is visible damage to the unit or power cables,
if the unit no longer operates correctly,
if the unit has been exposed to rain or moisture,
if foreign bodies have penetrated the unit,
after long storage under adverse conditions, or
after exposure to extreme stress in transit.
2.2
Installation and Operation
–
The relevant electrical engineering regulations and guidelines must be complied with at
all times during installation.
–
–
Relevant knowledge of network technology is required to install the unit.
Before installing or operating the module, please ensure you have read and understood
the documentation for the VIP X1600 XF base and for any other equipment connected to
the module, such as monitors. The documentation contains important safety instructions
and information about permitted uses.
–
Perform only the installation and operation steps described in this manual. Any other
actions may lead to personal injury, damage to property or damage to the equipment.
2.3
Maintenance and Repair
–
–
–
–
Never open the housing of a VIP X1600 XF base. The unit does not contain any user-
serviceable parts. Remove only the supplied cover when installing a module.
Do not change any components in a VIP X1600 XF base or a module. The units do not
contain any user-serviceable parts.
Never open the housing of the power supply unit. The power supply unit does not contain
any user-serviceable parts.
Ensure that all maintenance or repair work is carried out only by qualified personnel
(electrical engineers or network technology specialists).
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
10 en | Safety Information
VIP X1600 M4S
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Product Description | en
11
3
Product Description
3.1
Scope of Delivery
–
–
–
–
VIP X1600 M4S encoder module
Mounting kit for installation in the VIP X1600 XF base
Terminal plugs
Quick Installation Guide
NOTICE!
Check that the delivery is complete and in perfect condition. Arrange for the unit to be
checked by Bosch Security Systems if you find any damage.
3.2
System Requirements
General Requirements
–
–
–
–
–
–
VIP X1600 XF base or VIP X1600 B base housing
Computer with Windows XP or Windows Vista operating system
Network access (Intranet or Internet)
Screen resolution 1,024 × 768 pixels
16- or 32-bit color depth
Installed Sun JVM
NOTICE!
Please note the information in the System Requirements document on the product CD
supplied with the VIP X1600 XF base. If necessary, you can install the required programs and
controls from the product CD.
The Web browser must be configured to enable Cookies to be set from the IP address of the
unit.
Under Windows Vista, the protected mode on the Security tab under Internet Options must
be deactivated.
You can find notes on using Microsoft Internet Explorer in the online Help in Internet Explorer.
Additional Configuration Requirements
–
Microsoft Internet Explorer (version 6.0 or higher)
or
–
Installed Configuration Manager program (version 2.0 or higher)
Additional Operational Requirements
–
Microsoft Internet Explorer (version 6.0 or higher)
or
–
Receiver software, for example VIDOS (version 3.11 or higher) or Bosch Video
Management System (version 2.02 or higher)
or
–
–
MPEG-4 compatible hardware decoder from Bosch Security Systems (for example
VIP XD) as a receiver and connected video monitor
For playing back recordings: connection to storage medium
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
12 en | Product Description
VIP X1600 M4S
3.3
Overview of Functions
Network Video Encoder
The VIP X1600 M4S encoder module is a network video server for up to four independent
video channels. It is primarily designed for encoding video and control data for transfer over
an IP network. The audio version of the module also allows the transmission of audio signals
to compatible units. The use of existing networks means that integration with CCTV systems
or local networks can be achieved quickly and easily. The module offers a 2/3 D1 or 2CIF
resolution at a complete image rate of 25 (PAL) or 30 (NTSC) images per second for up to
four channels. Video images from a single sender can be received simultaneously on multiple
receivers.
The VIP X1600 M4S encoder module is designed for installation in the VIP X1600 XF base.
Installing the units is a quick and easy operation that does not require any additional tools. All
modules are hot swappable and can be exchanged while the system is running.
Receiver
Compatible MPEG-4 enabled hardware decoders (for example the VIP XD) can be used as
receivers. Computers with decoding software such as VIDOS or computers with the Microsoft
Internet Explorer Web browser can also be used as receivers.
Video Encoding
The VIP X1600 M4S encoder module uses the MPEG-4 video compression standard. Thanks to
efficient encoding, the data rate remains low even with high image quality and can also be
adapted to local conditions within wide limits.
Dual Streaming
Dual Streaming allows the incoming data stream to be encoded simultaneously according to
two different, individually customized profiles. This feature creates two data streams that can
serve different purposes, for example one for recording and one optimized for live
transmission over the LAN.
Multicast
In suitably configured networks, the multicast function enables simultaneous real-time video
transmission to multiple receivers. The UDP and IGMP V2 protocols must be implemented on
the network for this function.
Encryption
The VIP X1600 M4S encoder module offers a variety of options for protection against
unauthorized reading. Web browser connections can be protected using HTTPS. You can
protect the control channels via the SSL encryption protocol. With an additional license, the
user data itself can be encrypted.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Product Description | en
13
Remote Control
For remote control of external units such as pan or tilt heads for cameras or motorized zoom
lenses, control data is transmitted via the module's bidirectional serial interface. This
interface can also be used to transmit transparent data.
Tamper Detection and Motion Detectors
The VIP X1600 M4S encoder module offers a wide range of configuration options for alarm
signaling in the event of tampering with the connected camera. An algorithm for detecting
movement in the video image is also part of the scope of delivery and can optionally be
extended to include special video analysis algorithms.
Snapshots
Individual video frames (snapshots) can be called up as JPEG images, stored on the
computer's hard drive or displayed in a separate browser window.
Backup
A function for storing the video images displayed on the hard drive of your computer is
available on the LIVEPAGE as well as on the RECORDINGS page. Video sequences can be
stored by means of a mouse click and can be redisplayed using the Player supplied as part of
the scope of delivery of the base.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
14 en | Product Description
VIP X1600 M4S
Summary
The VIP X1600 M4S encoder module provides the following main functions:
–
–
Video and data transmission over IP data networks
Dual Streaming function for simultaneous encoding with two individually definable
profiles
–
–
–
–
–
Multicast function for simultaneous image transmission to multiple receivers
Four analog BNC composite video inputs (PAL/NTSC)
Video encoding to international standard MPEG-4
Transparent, bidirectional data channel via RS-232/RS-422/RS-485 serial interface
Configuration and remote control of all internal functions via TCP/IP, also secured via
HTTPS
–
–
–
–
–
–
–
–
Password protection to prevent unauthorized connection or configuration changes
Extensive, flexible storage options
Four alarm inputs and four relay outputs
Built-in video sensor for motion and tamper alarms
Event-controlled automatic connection
Convenient maintenance via uploads
Flexible encryption of control and data channels
Authentication according to international standard 802.1x
The audio version of the module also offers:
–
–
Audio signal transmission via IP data networks
Audio encoding to international standard G.711
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Product Description | en
15
3.4
Connections
1
2
Video inputs Video In 1 to Video In 4
BNC sockets for attaching video sources
Audio inputs (mono) Audio In 1/2 and Audio In 3/4
3.5 mm / 1/8 in. stereo sockets line-outs for connecting audio cables
(only audio versions of the module)
3
Terminal block
for alarm inputs, relay outputs and serial interface
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
16 en | Product Description
VIP X1600 M4S
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Installation | en
17
4
Installation
4.1
Preparations
The module is exclusively designed for installation in the VIP X1600 XF base. Installing the
units is a quick and easy operation that does not require any additional tools.
4.2
Installing Modules
Installation of the different VIP X1600 XF modules in the VIP X1600 XF base is described in
the relevant Quick Installation Guide. Please also take note of the following basic notes when
installing a unit.
CAUTION!
Do not install a module in a different housing and do not operate the unit outside of the
VIP X1600 XF base. The ambient temperature during installation must be between
0 and +50 °C (+32 and +122 °F), and the relative humidity must not exceed 80% (non-
condensing).
!
Installation Sequence and Capacity of the VIP X1600 XF Base
CAUTION!
Ensure that Slot 1 is always populated by a module, even when modifying the installation.
Malfunctions may occur when the VIP X1600 XF is switched on without a functional module in
Slot 1.
!
!
You can install up to four modules in a VIP X1600 XF base. Slot 1 must always be the first slot
that is populated. The remaining slots can be populated in any order desired. It is also
possible to install and remove modules during operation.
Cooling
CAUTION!
Whenever the installation is modified, or modules are exchanged or supplemented, it is
essential that all unpopulated slots are properly covered on the rear panel of the VIP X1600 XF
base.
The installed modules generate a high volume of heat during operation. As a result, it is
essential that a functional heat dissipation system is in place for problem-free operation of a
VIP X1600 XF.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
18 en | Installation
VIP X1600 M4S
Rating Plates
Every module has a label on the circuit board containing a printed MAC address by which the
module can be uniquely identified. Take note of this MAC address and the location in the
VIP X1600 XF base before installation so that you can later identify the module, even after it
has been inserted, for example when performing fault diagnosis.
Removing and Exchanging Modules
It is also possible to install, remove and exchange modules during operation.
CAUTION!
Ensure that Slot 1 is always populated by a module, even when modifying the installation.
Malfunctions may occur when the VIP X1600 XF is switched on without a functional module in
Slot 1.
!
1. Before removing a module, terminate all recordings currently running in this module.
2. When installing a module, please ensure that the cover is kept for future use.
3. When removing a module, it is essential that the corresponding slot be closed with the
cover if a module is no longer to be used in this slot. The opening must be closed to
ensure that the unit remains cool.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Installation | en
19
4.3
Connections
Cameras
You can connect a maximum of four video sources to the module. Any cameras and other
video sources that produce a standard PAL or NTSC signal are suitable.
1. Connect the cameras or other video sources to the BNC sockets Video In 1 to Video In 4
using a video cable (75 Ohm, BNC plug).
2. If the video signal is not looped through, termination is performed by a software setting if
necessary (see Section 5.17 Advanced Mode: Video Input, page 42).
Audio Connections
The audio version of the VIP X1600 M4S module has two audio line inputs for a total of four
mono signals.
The audio signals are transmitted at the same time as the video signals. As a result, you can
connect a speaker or door intercom system at the destination point, for example. The
following specification should be complied with in all cases:
Impedance 9 kOhm typ., 5.5 V
max. input voltage.
p-p
The stereo plugs must be connected as follows:
Contact
Tip
Audio In 1/2
Channel 1
Channel 2
Ground
Audio In 3/4
Channel 3
Channel 4
Ground
Middle ring
Lower ring
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
20 en | Installation
VIP X1600 M4S
Data interface
The bidirectional data interface is used to control units connected to the module, such as a
dome camera with a motorized lens. The connection supports the RS-232, RS-422 and RS-485
The module offers the serial interface via the orange terminal block (see Section 8.8 Terminal
Block, page 107).
The range of controllable equipment is expanding constantly. The manufacturers of the
relevant equipment provide specific information on installation and control.
CAUTION!
Please take note of the appropriate documentation when installing and operating the unit to
be controlled.
!
The documentation contains important safety instructions and information about permitted
uses.
NOTICE!
A video connection is necessary to transmit transparent data.
The module offers four alarm inputs via the orange terminal block (see Section 8.8 Terminal
Block, page 107). The alarm inputs are used to connect to external alarm devices such as door
contacts or sensors. With the appropriate configuration, an alarm sensor can automatically
connect the VIP X1600 XF to a remote location, for example.
A zero potential closing contact or switch can be used as the actuator.
NOTICE!
If possible, use a bounce-free contact system as the actuator.
X
Connect the lines to the appropriate terminals on the orange terminal block (IN1 to IN4)
and check that the connection is secure.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Installation | en
21
Relay Outputs
The module has four relay outputs for switching external units such as lamps or alarm sirens.
You can operate these relay outputs manually while there is an active connection to the
units in response to an alarm signal. The relay outputs are also located on the orange terminal
block (see Section 8.8 Terminal Block, page 107).
CAUTION!
A maximum load of 30 V and 2 A may be applied to the relay contacts.
!
X
Connect the lines to the appropriate terminals on the orange terminal block (R1 to R4)
and check that the connections are secure.
4.4
Setup Using the Configuration Manager
The Configuration Manager program can be found on the product CD contained in the
VIP X1600 XF base's scope of delivery. This program allows you to implement and set up new
modules quickly and conveniently.
NOTICE!
Using the Configuration Manager to set all parameters in the module is an alternative to
configuration by means of a Web browser, as described in chapter 5 of this manual.
Installing the Program
1. Insert the CD into the computer's CD-ROM drive.
2. If the CD does not start automatically, open the Configuration Manager directory using
Windows Explorer and double-click Setup.exe.
3. Follow the on-screen instructions.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
22 en | Installation
VIP X1600 M4S
Configuring the Module
You can start the Configuration Manager immediately after installation.
1. Double-click the icon on the desktop or start the program via the Start menu. After the
program has started, the network is immediately searched for compatible video servers.
2. You can start the configuration if the module is shown in the list in the left section of the
window. To do this, right-click the entry for the module.
3. Click Unit network settings... in the popup menu.
4. In the Unit IP address field, enter a valid IP address for your network (for example
192.168.0.17) and click OK. The unit reboots and the IP address is valid.
5. If required, enter an appropriate subnet mask for the IP address, and additional network
data.
NOTICE!
You must reboot to activate the new IP address, a new subnet mask or a gateway IP address.
Reboot
You can trigger the reboot directly with the assistance of the Configuration Manager.
X
Right click the entry for the module in the list in the left section of the window and select
the Reset command.
Additional Parameters
You can check and set additional parameters with the assistance of the Configuration
Manager. You can find detailed information on this in the documentation for this program.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
23
5
Configuration Using a Web Browser
5.1
Connecting
The integrated HTTP server in the module offers you the option of configuring the unit over
the network with a Web browser. This option is an alternative to configuration using the
Configuration Manager program and is considerably richer in function and more convenient
than configuration using the terminal program.
System requirements
–
–
–
–
–
–
Computer with Windows XP or Windows Vista operating system
Network access (Intranet or Internet)
Microsoft Internet Explorer (version 6.0 or higher)
Screen resolution 1,024 × 768 pixels
16- or 32-bit color depth
Installed Sun JVM
NOTICE!
Please note the information in the System Requirements document on the product CD
supplied with the VIP X1600 XF base. If necessary, you can install the required programs and
controls from the product CD.
The Web browser must be configured to enable Cookies to be set from the IP address of the
unit.
Under Windows Vista, the protected mode on the Security tab under Internet Options must
be deactivated.
You can find notes on using Microsoft Internet Explorer in the online Help in Internet Explorer.
Installing MPEG ActiveX
Suitable MPEG ActiveX software must be installed on the computer to allow the live video
images to be played back. If necessary, you can install the program from the product CD.
1. Insert the product CD into the computer's CD-ROM drive. If the CD does not start
automatically, open the root directory of the CD in Windows Explorer and double-click
MPEGAx.exe.
2. Follow the on-screen instructions.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
24 en | Configuration Using a Web Browser
VIP X1600 M4S
Establishing the Connection
At least the module in Slot 1 must be assigned a valid IP address and a compatible subnet
mask to operate the VIP X1600 XF on your network.
The following default address is preset at the factory: 192.168.0.1
1. Start the Web browser.
2. Enter the module's IP address as the URL. The connection is established and after a short
time you will see the LIVEPAGE with the video image.
Maximum Number of Connections
If you do not connect, the unit may have reached its maximum number of connections.
Depending on the unit and network configuration, each module can have up to 25 Web
browser connections or up to 50 connections via VIDOS or Bosch Video Management System.
Protected Module
If the module is password protected against unauthorized access, the Web browser displays a
message to that effect and prompts you to enter the password when you call up access-
protected areas.
The module offers the option to limit the extent of access using various authorization levels
(see Section 5.11 Advanced Mode: Password, page 35).
1. Enter the user name and associated password in the corresponding text fields.
2. Click OK. If the password is entered correctly, the Web browser displays the page that
was called up.
Protected Network
If a RADIUS server is employed in the network for managing access rights (802.1x
authentication), the module must be configured accordingly, otherwise no communication is
possible.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
25
To configure the unit, you must connect the VIP X1600 XF directly to a computer using a
network cable. This is because communication via the network is not enabled until the
Identity and Password parameters have been set and successfully authenticated (see
Section 5.38 Advanced Mode: Advanced, page 77).
CAUTION!
The switch used for the network must support the multi-host operation when using 802.1x
authentication and must be configured so that a VIP X1600 XF with several modules can try
several hosts for communicating over the network.
!
5.2
Configuration Menu
The SETTINGS page provides access to the configuration menu, which contains all the unit's
parameters arranged in groups. You can view the current settings by opening one of the
configuration screens. You can change the settings by entering new values or by selecting a
predefined value from a list field.
There are two options for configuring the unit or checking the current settings:
–
–
Basic mode
Advanced mode
In Basic Mode the most important parameters are arranged in seven groups. This allows you
to change the basic settings with just a few entries and then put the device into operation.
Advanced Mode is recommended for expert users or system support personnel. You can
access all unit parameters in this mode. Settings that affect the fundamental functionality of
the unit (such as firmware updates) can only be altered in the advanced mode.
All parameter groups are described in this chapter in the order in which they are listed in the
configuration menu, from the top of the screen to the bottom.
CAUTION!
The settings in the advanced mode should only be processed or modified by expert users or
system support personnel.
!
All settings are stored in the module's memory so that they are retained even if the power
supply is interrupted.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
26 en | Configuration Using a Web Browser
VIP X1600 M4S
Starting Configuration
X
Click the SETTINGS link in the upper section of the window. The Web browser opens a
new page with the configuration menu.
Navigation
1. Click one of the menu items in the left window margin. The corresponding submenu is
displayed.
2. Click one of the entries in the submenu. The Web browser opens the corresponding
page.
Making Changes
Each configuration screen shows the current settings. You can change the settings by entering
new values or by selecting a predefined value from a list field.
X
After each change, click Set to save the change.
CAUTION!
Save each change with the associated Set button.
Clicking the Set button saves the settings only in the current field. Changes in any other fields
are ignored.
!
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
27
5.3
Basic Mode: Unit Access
Device name
You can give the module a name to make it easier to identify. The name makes the task of
administering multiple units in larger video monitoring systems easier, for example using the
VIDOS or Bosch Video Management System programs.
The device name is used for the remote identification of a module, in the event of an alarm for
example. For this reason, enter a name that makes it as easy as possible to quickly identify the
location.
CAUTION!
Do not use any special characters, for example &, in the name.
Special characters are not supported by the system's internal recording management and may
therefore result in the Player or Archive Player being unable to play back the recording.
!
Camera 1 to Camera 4
The camera name makes it easier to identify the remote camera location, in the event of an
alarm for example. It will be displayed in the video screen if configured to do so (see
Section Camera name stamping, page 37). The camera name makes the task of administering
cameras in larger video monitoring systems easier, for example using the VIDOS or Bosch
Video Management System programs.
Enter a unique, unambiguous name for the camera in this field.
CAUTION!
Do not use any special characters, for example &, in the name.
Special characters are not supported by the system's internal recording management and may
therefore result in the Player or Archive Player being unable to play back the recording.
!
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
28 en | Configuration Using a Web Browser
VIP X1600 M4S
Password
A module is generally protected by a password to prevent unauthorized access to the unit.
You can use different authorization levels to limit access.
The module operates with three authorization levels: service, user and live.
The highest authorization level is service. After entering the correct password, this user name
allows you to use all the functions of the module and change all configuration settings.
With the user authorization level, you can operate the unit and also control cameras, for
example, but you cannot change the configuration.
The lowest authorization level is live. It can only be used to view the live video image and
switch between the different live image displays.
You can define and change a password for each authorization level if you are logged in as
service or if the unit is not password protected.
Enter the password for the appropriate authorization level here.
NOTICE!
Proper password protection is only guaranteed when all higher authorization levels are also
protected with a password. If a live password is assigned, for example, a service and a user
password must also be set. When assigning passwords, you should therefore always start
from the highest authorization level, service, and use different passwords.
Confirm password
In each case, enter the new password a second time to eliminate typing mistakes.
NOTICE!
A new password is only saved when you click the Set button. You should therefore click the
Set button immediately after entering and confirming a password.
5.4
Basic Mode: Date/Time
Unit date/Unit time/Unit time zone
NOTICE!
The module in Slot 1 of the VIP X1600 XF is the time server for the modules in Slots 2 to 4.
Consequently, the Sync to PC button is only active for the module in Slot 1. The button is
deactivated for modules in Slots 2 to 4.
If there are multiple devices operating in your system or network, it is important to
synchronize their internal clocks. For example, it is only possible to identify and correctly
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
29
evaluate simultaneous recordings when all units are operating on the same time. If necessary,
you can synchronize the module with your computer's system settings.
X
Click the Sync to PC button to copy your computer's system time to the module.
Time server IP address
The module can receive the time signal from a time server using various time server protocols,
and then use it to set the internal clock. The module polls the time signal automatically once
every minute.
X
Enter the IP address of a time server here.
Time server type
Select the protocol that is supported by the selected time server. Preferably, you should
select the SNTP server as the protocol. This supports a high level of accuracy and is required
for special applications and subsequent function extensions.
Select Time server for a time server that works with the protocol RFC 868.
5.5
Basic Mode: Network
The settings in this screen are used to integrate the module into an existing network.
Some changes only take effect after the module is rebooted. In this case, the Set button
changes to Set and Reboot.
1. Make the desired changes.
2. Click the Set and Reboot button. The module is rebooted and the changed settings are
activated.
CAUTION!
If you change the IP address, subnet mask or gateway address, the module is only available
under the new addresses after the reboot.
!
DHCP
If a DHCP server is employed in the network for the dynamic assignment of IP addresses, you
can activate acceptance of IP addresses automatically assigned to the module.
Certain applications (VIDOS, Bosch Video Management System, Archive Player, Configuration
Manager) use the IP address for the unique assignment of the unit. If you use these
applications, the DHCP server must support the fixed assignment between IP address and
MAC address, and must be appropriately set up so that, once an IP address is assigned, it is
retained each time the system is rebooted.
IP address
Enter the desired IP address for the module. The IP address must be valid for the network.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
30 en | Configuration Using a Web Browser
VIP X1600 M4S
Subnet mask
Enter the appropriate subnet mask for the selected IP address here.
Gateway address
If you want the module to establish a connection to a remote location in a different subnet,
enter the IP address of the gateway here. Otherwise leave the box blank (0.0.0.0).
5.6
Basic Mode: Encoder Profile
Video input
Select a video input for the module here; the profile selected in the next field will be applied
to this input. You can select a specific profile for each video input.
Active profile
You can select a profile for encoding the video signal.
You can use this to adapt the video data transmission to the operating environment (for
example network structure, bandwidth, data load).
Pre-programmed profiles are available, each giving priority to different perspectives. When
selecting a profile, details are displayed in the list field.
–
–
–
–
–
–
Low bandwidth (CIF)
High quality for low bandwidth connections, resolution 352 × 288/240 pixels
Low delay (2/3 D1)
High quality with low delay, resolution 464 × 576/480 pixels
High resolution (4CIF/D1)
High resolution for high bandwidth connections, resolution 704 × 576/480 pixels
DSL
For DSL connections with 500 kbps, resolution 352 × 288/240 pixels
ISDN (2B)
For ISDN connections via two B-channels, resolution 352 × 288/240 pixels
ISDN (1B)
For ISDN connections via one B-channel, resolution 352 × 288/240 pixels
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
31
–
–
Modem
For analog modem connections with 20 kbps, resolution 352 × 288/240 pixels
GSM
For GSM connections at 9,600 baud, resolution 176 × 144/120 pixels
5.7
Basic Mode: Audio (Audio Version Only)
You can set the gain of the audio signals to suit your specific requirements. The current video
image is shown in the small window next to the slide controls to help you check the audio
If you connect via Web browser, you must activate the audio transmission on the LIVEPAGE
Functions page (see Section 5.15 Advanced Mode: LIVEPAGE Functions, page 40). For other
connections, the transmission depends on the audio settings of the respective system.
Audio
The audio signals are sent in a separate data stream parallel to the video data, and so increase
the network load. The audio data are encoded according to G.711 and require an additional
bandwidth of approx. 80 kbps for each connection. If you do not want any audio data to be
transmitted, select Off.
Line In 1 to Line In 4
You can set the gain for the line inputs. Make sure that the display does not go beyond the
green zone during modulation.
5.8
Basic Mode: Recording
You can record the images from the camera connected to the module on an appropriately
configured iSCSI system.
You can start or stop the recording immediately here.
Storage medium
1. Select the required storage medium from the list.
2. Click the Start button to start the recording immediately.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
32 en | Configuration Using a Web Browser
VIP X1600 M4S
5.9
Basic Mode: System Overview
The data on this page are for information purposes only and cannot be changed. Keep a
record of these numbers in case technical assistance is required.
NOTICE!
You can select all required text on this page with the mouse and copy it to the clipboard with
the [Ctrl]+[C] key combination, for example if you want to send it via e-mail.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
33
5.10
Advanced Mode: Identification
Device ID
Each module should be assigned a unique identifier that you can enter here as an additional
means of identification.
Device name
You can give the module a name to make it easier to identify. The name makes the task of
administering multiple units in larger video monitoring systems easier, for example using the
VIDOS or Bosch Video Management System programs.
The device name is used for the remote identification of a module, in the event of an alarm for
example. For this reason, enter a name that makes it as easy as possible to quickly identify the
location.
CAUTION!
Do not use any special characters, for example &, in the name.
Special characters are not supported by the system's internal recording management and may
therefore result in the Player or Archive Player being unable to play back the recording.
!
Camera 1 to Camera 4
The camera name makes it easier to identify the remote camera location, in the event of an
alarm for example. It will be displayed in the video screen if configured to do so (see
Section Camera name stamping, page 37). The camera name makes the task of administering
cameras in larger video monitoring systems easier, for example using the VIDOS or Bosch
Video Management System programs.
Enter a unique, unambiguous name for the camera in this field. You can use both lines for this.
CAUTION!
Do not use any special characters, for example &, in the name.
Special characters are not supported by the system's internal recording management and may
therefore result in the Player or Archive Player being unable to play back the recording.
!
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
34 en | Configuration Using a Web Browser
VIP X1600 M4S
You can use the second line for entering additional characters; these can be selected from a
table.
1. Click the icon next to the second line. A new window with the character map is opened.
2. Click the required character. The character is inserted into the Result field.
3. In the character map, click the << and >> icons to move between the different pages of
the table, or select a page from the list field.
4. Click the < icon to the right of the Result field to delete the last character, or click the X
icon to delete all characters.
5. Now click the OK button to apply the selected characters to the second line of the
Camera parameters. The window will close.
Initiator extension
You can attach your own text to the initiator name of the module to make the unit easier to
identify in large iSCSI systems. This text is added to the initiator name, separated from it by a
full stop. You can see the initiator name in the system overview (see Section 5.46 Advanced
Mode: System Overview, page 87).
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
35
5.11
Advanced Mode: Password
A module is generally protected by a password to prevent unauthorized access to the unit.
You can use different authorization levels to limit access.
NOTICE!
Proper password protection is only guaranteed when all higher authorization levels are also
protected with a password. If a live password is assigned, for example, a service and a user
password must also be set. When assigning passwords, you should therefore always start
from the highest authorization level, service, and use different passwords.
Password
The module operates with three authorization levels: service, user and live.
The highest authorization level is service. After entering the correct password, this user name
allows you to use all the functions of the module and change all configuration settings.
With the user authorization level, you can operate the unit and also control cameras, for
example, but you cannot change the configuration.
The lowest authorization level is live. It can only be used to view the live video image and
switch between the different live image displays.
You can define and change a password for each authorization level if you are logged in as
service or if the unit is not password protected.
Enter the password for the appropriate authorization level here.
Confirm password
In each case, enter the new password a second time to eliminate typing mistakes.
NOTICE!
A new password is only saved when you click the Set button. You should therefore click the
Set button immediately after entering and confirming a password.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
36 en | Configuration Using a Web Browser
VIP X1600 M4S
5.12
Advanced Mode: Date/Time
NOTICE!
The module in Slot 1 of the VIP X1600 XF is the time server for the modules in Slots 2 to 4.
Consequently, the date and time settings can only be changed for the module in Slot 1. These
parameters are deactivated for modules in Slots 2 to 4.
Date format (only for the module in Slot 1)
Select your required date format.
Unit date/Unit time (only for the module in Slot 1)
If there are multiple devices operating in your system or network, it is important to
synchronize their internal clocks. For example, it is only possible to identify and correctly
evaluate simultaneous recordings when all units are operating on the same time.
1. Enter the current date. Since the unit time is controlled by the internal clock, there is no
need to enter the day of the week – it is added automatically.
2. Enter the current time or click the Sync to PC button to copy your computer's system
time to the module.
Unit time zone
Select the time zone in which your system is located.
Daylight saving time
The internal clock can switch automatically between normal and daylight saving time (DST).
The unit already contains the data for DST switch-overs up to the year 2018. You can use
these data or create alternative time saving data if required.
NOTICE!
If you do not create a table, there will be no automatic switching. When changing and clearing
individual entries, remember that two entries are usually related to each other and dependent
on one another (switching to summer time and back to normal time).
1. First check whether the correct time zone is selected. If it is not correct, select the
appropriate time zone for the system, and click the Set button.
2. Click the Details button. A new window will open and you will see the empty table.
3. Select the region or the city that is closest to the system's location from the list field
below the table.
4. Click the Generate button to generate data and enter this into the table.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
37
5. Make changes by clicking an entry in the table. The entry is selected.
6. Clicking the Delete button will remove the entry from the table.
7. Select other values from the list fields below the table to change the entry. Changes are
made immediately.
8. If there are empty lines at the bottom of the table, for example after deletions, you can
add new data by marking the row and selecting required values from the list fields.
9. Now click the OK button to save and activate the table.
Time server IP address
The module can receive the time signal from a time server using various time server protocols,
and then use it to set the internal clock. The module polls the time signal automatically once
every minute.
Enter the IP address of a time server here.
Time server type
Select the protocol that is supported by the selected time server. Preferably, you should
select the SNTP server as the protocol. This supports a high level of accuracy and is required
for special applications and subsequent function extensions.
Select Time server for a time server that works with the protocol RFC 868.
5.13
Advanced Mode: Display Stamping
Various overlays or "stamps" in the video image provide important supplementary information.
These overlays can be enabled individually and are arranged on the image in a clear manner.
NOTICE!
The settings on this page apply to all camera inputs of the module.
Camera name stamping
This field sets the position of the camera name overlay. It can be displayed at the Top, at the
Bottom or at a position of your choice that you can then specify using the Custom option. Or
it can be set to Off for no overlay information.
1. Select the desired option from the list.
2. If you select the Custom option, additional fields are displayed where you can specify the
exact position (Position (XY)).
3. In the Position (XY) fields, enter the values for the desired position.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
38 en | Configuration Using a Web Browser
VIP X1600 M4S
Time stamping
This field sets the position of the time overlay. It can be displayed at the Top, at the Bottom or
at a position of your choice that you can then specify using the Custom option. Or it can be
set to Off for no overlay information.
1. Select the desired option from the list.
2. If you select the Custom option, additional fields are displayed where you can specify the
exact position (Position (XY)).
3. In the Position (XY) fields, enter the values for the desired position.
Display milliseconds
If necessary, you can also display milliseconds. This information can be useful for recorded
video images; however, it does increase the processor's computing time. Select Off if you do
not need to display milliseconds.
Alarm mode stamping
Select On to display a text message overlay in the image in the event of an alarm. It can be
displayed at a position of your choice that you can then specify using the Custom option. Or it
can be set to Off for no overlay information.
1. Select the desired option from the list.
2. If you select the Custom option, additional fields are displayed where you can specify the
exact position (Position (XY)).
3. In the Position (XY) fields, enter the values for the desired position.
Alarm message
Enter the message to be displayed in the image in the event of an alarm. The maximum text
length is 31 characters.
Video watermarking
Choose On if you wish the transmitted video images to be "watermarked". After activation, all
images are marked with a green W. A red W indicates that the sequence (live or saved) has
been manipulated.
5.14
Advanced Mode: Appearance
On this page you can adapt the appearance of the web interface and change the website
language to meet your requirements. If necessary, you can replace the manufacturer's logo
(top right) and the product name (top left) in the top part of the window with individual
graphics.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
39
NOTICE!
You can use either GIF or JPEG images. The file paths must correspond to the access mode
(for example C:\Images\Logo.gif for access to local files, or http://www.mycompany.com/
images/logo.gif for access via the Internet/Intranet).
When accessing via the Internet/Intranet, ensure that a connection is always available to
display the image. The image file is not saved in the module.
Website language
Select the language for the user interface here.
NOTICE!
There are always two languages to choose from: English and another language. If the language
you require is not available for selection, you can download the current firmware with another
language combination from the website www.boschsecurity.com.
Company logo
Enter the path to a suitable graphic if you want to replace the manufacturer's logo. The image
file can be stored on a local computer, in the local network or at an Internet address.
Device logo
Enter the path to a suitable graphic if you want to replace the product name. The image file
can be stored on a local computer, in the local network or at an Internet address.
NOTICE!
If you want to use the original graphics again, simply delete the entries in the Company logo
and Device logo fields.
JPEG size
You can choose between two given image sizes to display the M-JPEG image on the
LIVEPAGE.
JPEG interval
You can specify the interval at which the individual images should be generated for the M-
JPEG image on the LIVEPAGE.
JPEG quality
You can specify the image quality for displaying M-JPEG on the LIVEPAGE.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
40 en | Configuration Using a Web Browser
VIP X1600 M4S
5.15
Advanced Mode: LIVEPAGE Functions
On this page you can adapt the LIVEPAGE functions to your requirements. You can choose
from a variety of different options for displaying information and controls.
1. Check the box for the items that are to be made available on the LIVEPAGE. The selected
items are indicated by a check mark.
2. Check whether the required functions are available on the LIVEPAGE.
Transmit audio
The audio signals are sent in a separate data stream parallel to the video data, and so increase
the network load. The audio data are encoded according to G.711 and require an additional
bandwidth of approx. 80 kbps for each connection.
Show alarm inputs
Alarm inputs are shown next to the video image as icons, along with their assigned names. If
an alarm is active, the corresponding icon changes color.
Show relay outputs
Relay outputs are shown next to the video image as icons, along with their assigned names. If
the relay is switched, the icon changes color.
Show VCA trajectories
The trajectories (motion lines of objects) from the video content analysis are displayed in the
live video image if a corresponding analysis type is activated (see Section 5.30 Advanced Mode:
VCA Event Triggered, page 66).
Show VCA metadata
When the analysis function is activated, the additional information from the video content
analysis (VCA) will be displayed in the live video image (see Section 5.30 Advanced Mode: VCA
Event Triggered, page 66). With the MOTION+ analysis type, for example, the sensor fields in
which motion is recorded will be marked with rectangles.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
41
Show event log
The event messages are displayed along with the date and time in a field next to the video
image.
Show system log
The system messages are displayed along with the date and time in a field next to the video
image and provide information about establishing and ending connections, for example.
Allow snapshots
Here you can specify whether the icon for saving individual images should be displayed below
the live image. Individual images can only be saved if this icon is visible.
Allow local recording
Here you can specify whether the icon for saving video sequences on the local memory should
be displayed below the live image. Video sequences can only be saved if this icon is visible.
Path for JPEG and MPEG files
1. Enter the path for the storage location of individual images and video sequences that you
can save from the LIVEPAGE.
2. If necessary, click Browse to find a suitable directory.
5.16
Advanced Mode: Logging
Save event log
Check this option to save event messages in a text file on your local computer.
You can then view, edit and print this file with any text editor or the standard Office software.
File for event log
1. Enter the path for saving the event log here.
2. If necessary, click Browse to find a suitable directory.
Save system log
Check this option to save system messages in a text file on your local computer.
You can then view, edit and print this file with any text editor or the standard Office software.
File for system log
1. Enter the path for saving the system log here.
2. If necessary, click Browse to find a suitable directory.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
42 en | Configuration Using a Web Browser
VIP X1600 M4S
5.17
Advanced Mode: Video Input
You can activate the 75 Ohm terminating resistor for each video input on the module. The
terminating resistance must be deactivated for the video signal to be looped through. Every
video input is closed at the time of delivery.
NOTICE!
The numbering follows the labeling of the video inputs on the actual module.
75 Ohm termination
Select Off if the video signal is to be looped through.
Source type
To allow VCRs to be connected as a video source, you can change the characteristic of the
video source from the preset value of Camera to VCR. VCRs require a more tolerant setting
for the internal PLL as a result of jitter effects caused by the mechanical components of a
VCR.
NOTICE!
In some cases, selecting the VCR option can lead to an improvement in the video image even
with a camera connected.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
43
5.18
Advanced Mode: Picture Settings
You can set the video image of each camera to suit your requirements. The current video
image is displayed in the small window next to the slide controls as confirmation. Your
changes are effective immediately.
1. Click a tab to select the corresponding camera.
2. Move the slide control to the required position.
3. Click Default to reset all settings to their default value.
Contrast (0...255)
You can use this function to adapt the contrast of the video image to your working
environment.
Saturation (0...255)
You can use this function to adjust the color saturation so as to make the reproduction of
colors on your monitor as realistic as possible.
Brightness (0...255)
You can use this function to adapt the brightness of the video image to your working
environment.
Low-pass filter (0...255)
You can use this function to filter very fine noise from the image. This reduces and optimizes
the bandwidth necessary for image transmission over the network. The image resolution may
be impaired.
The higher the value set with the slide control, the flatter the image signal. Check your setting
in the image window next to the slide controls.
Also observe the processor load indicator that appears at the top of the window near the
manufacturer's logo.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
44 en | Configuration Using a Web Browser
VIP X1600 M4S
5.19
Advanced Mode: Encoder Profile
For the video signal encoding, you can select two profiles and a code algorithm for each video
input, and you can change the presets for the profiles.
You can adapt the video data transmission to the operating environment (for example network
structure, bandwidth, data load). To this end, the module simultaneously generates two data
streams (Dual Streaming). You can select the compression settings of these data streams
individually, for example one setting for transmissions to the Internet and one for LAN
connections.
Pre-programmed profiles are available, each giving priority to different perspectives.
–
Low bandwidth (CIF)
High quality for low bandwidth connections, resolution 352 × 288/240 pixels
Low delay (2/3 D1)
–
High quality with low delay, resolution 464 × 576/480 pixels
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
45
–
–
–
–
–
–
High resolution (4CIF/D1)
High resolution for high bandwidth connections, resolution 704 × 576/480 pixels
DSL
For DSL connections with 500 kbps, resolution 352 × 288/240 pixels
ISDN (2B)
For ISDN connections via two B-channels, resolution 352 × 288/240 pixels
ISDN (1B)
For ISDN connections via one B-channel, resolution 352 × 288/240 pixels
Modem
For analog modem connections with 20 kbps, resolution 352 × 288/240 pixels
GSM
For GSM connections at 9,600 baud, resolution 176 × 144/120 pixels
You can choose between the code algorithms MPEG-4 SH++ and H.264 for each data stream.
H.264 requires a lower bandwidth at the same video quality but it does not offer 4CIF
resolution. 4CIF resolution is only possible with MPEG-4 SH++.
1. Select the required profile for every data stream.
2. Select the required code algorithm for every data stream.
You can change individual parameter values of a profile and you can also change the name.
You can switch between profiles by clicking the appropriate tabs.
CAUTION!
The profiles are rather complex. They include a large number of parameters that interact with
one another, so it is generally best to use the default profiles.
Change the profiles only once you are fully familiar with all the configuration options.
In the default setting, Stream 2 is transmitted for alarm connections and automatic
connections. Bear this fact in mind when assigning the profile.
!
NOTICE!
All parameters combine to make up a profile and are dependent on one another. If you enter a
setting that is outside the permitted range for a particular parameter, the nearest permitted
value will be substituted when the settings are saved.
Preview for
Select which video data stream should be displayed in the previews. You can deactivate the
display of the video images if the performance of the computer is affected too strongly by the
decoding of the data streams.
1. Check the box for the required data stream.
2. Click the i icon above the relevant preview to display further information about the data
stream.
Profile name
You can enter a new name for the profile here. The name is then displayed in the list of
available profiles in the Active profile field.
Target data rate
You can limit the data rate for the module to optimize utilization of the bandwidth in your
network. The target data rate should be set according to the desired picture quality for typical
scenes with no excessive motion.
For complex images or frequent changes of image content due to frequent movements, this
limit can be temporarily exceeded up to the value you enter in the Maximum data rate field.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
46 en | Configuration Using a Web Browser
VIP X1600 M4S
Encoding interval
The figure selected here determines the interval at which images are encoded and
transmitted. For example, entering 4 means that only every fourth image is encoded, the
following three are skipped - this can be particularly advantageous with low bandwidths. The
image rate in ips (images per second) is displayed next to the text field.
Video resolution
Here you can select the desired resolution for the video image. The following resolutions are
available:
–
–
–
–
–
–
QCIF
176 × 144/120 pixels
CIF
352 × 288/240 pixels
1/2 D1
352 × 576/480 pixels
2CIF
704 × 288/240 pixels
4CIF/D1
704 × 576/480 pixels
2/3 D1
464 × 576/480 pixels
Default
Click Default to return the profile to the factory default values.
Details
Clicking the Details >> button displays further details on image quality and data transmission.
These settings require extensive knowledge of the MPEG standard and video data
compression. Incorrect settings can render the video images unusable.
Maximum data rate
This maximum data rate is not exceeded under any circumstances. Depending on the video
quality settings for the I- and P-frames, this fact can result in individual images being skipped.
The value entered here must be at least 10% higher than the value entered in the Target data
rate field. If the value entered here is too low, it will automatically be adjusted.
I-frame distance
This parameter allows you to set the intervals in which the I-frames will be coded. 0 means
auto mode, whereby the video server inserts I-frames as necessary. An entry of 1 indicates
that I-frames are continuously generated. An entry of 2 indicates that only every second image
is an I-frame, and 3 only every third image etc.; the frames in between are coded as P-frames.
Video quality
This setting allows you to adjust the image quality. The Auto option automatically adjusts to
the optimum combination of movement and image definition (focus). Alternatively, you can
use the slide control to select a value between 1 and 100. A value of 100 results in a very high
refresh rate and lower image quality.
H.264 deblocking filter
You can activate a filter that reduces blocking in the image in the case of H.264-encoded video
streams, thereby providing a smoother image. Please note that this option requires additional
computing power.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
47
Priority
In the default configuration None, the computing power provided for individual tasks is
negotiated dynamically. This ensures the best possible video quality at all times. With the
MPEG-4/H.264 setting, video transmissions are given a higher priority and only a small
amount of power remains available for JPEG images. The JPEG setting is suitable for
applications that primarily require JPEG images, for example JPEG recordings. When this
setting is made the amount of power available for video images will be reduced.
5.20
Advanced Mode: Audio (Audio Version Only)
You can set the gain of the audio signals to suit your specific requirements. The current video
image is shown in the small window next to the slide controls to help you check the audio
If you connect via Web browser, you must activate the audio transmission on the LIVEPAGE
Functions page (see Section 5.15 Advanced Mode: LIVEPAGE Functions, page 40). For other
connections, the transmission depends on the audio settings of the respective system.
Audio
The audio signals are sent in a separate data stream parallel to the video data, and so increase
the network load. The audio data are encoded according to G.711 and require an additional
bandwidth of approx. 80 kbps for each connection. If you do not want any audio data to be
transmitted, select Off.
Line In 1 to Line In 4
You can set the gain for the line inputs. Make sure that the display does not go beyond the
green zone during modulation.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
48 en | Configuration Using a Web Browser
VIP X1600 M4S
5.21
Advanced Mode: Storage Management
You can record the images from the camera connected to the module on an appropriately
configured iSCSI system.
It is also possible to let the VRM Video Recording Manager control all recording when
accessing an iSCSI system. This is an external program for configuring recording tasks for
video servers. For further information please contact your local customer service at Bosch
Security Systems.
Device manager
If you activate the VRM option in this screen, the VRM Video Recording Manager will manage
all recording and you will not be able to configure any further settings here.
CAUTION!
Activating or deactivating VRM causes the current settings to be lost; they can only be
restored through reconfiguration.
!
Recording media
Select the required recording media here so that you can then activate them and configure
the recording parameters.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
49
iSCSI Media
If you want to use an iSCSI system as a recording medium, you must set up a connection to
the required iSCSI system and set the configuration parameters.
NOTICE!
The iSCSI storage system selected must be available on the network and completely set up.
Amongst other things, it must have an IP address and be divided into logical drives (LUN).
1. Enter the IP address of the required iSCSI destination in the iSCSI IP address field.
2. If the iSCSI destination is password protected, enter this into the Password field.
3. Click the Read button. The connection to the IP address will be established. In the
Storage overview field, you can see the corresponding logical drives.
Activating and Configuring Storage Media
The storage overview displays the available storage media. You can select individual iSCSI
drives and transfer these to the Managed storage media list. You can activate the storage
media in this list and configure them for storage.
CAUTION!
Each storage medium can only be associated with one user. If a storage medium is already
being used by another user, you can decouple the user and connect the drive with the module.
Before decoupling, make absolutely sure that the previous user no longer needs the storage
medium.
!
1. In the Storage overview section, double-click an ISCSI LUN. The medium is then added
to the Managed storage media list. In the Status column, newly added media are
indicated by the status Not active.
2. Click the Set button to activate all media in the Managed storage media list. In the
Status column, these are indicated by the status Online.
3. Check the box in the Rec. 1 or Rec. 2 column to specify which data stream should be
recorded on the storage media selected. Rec. 1 stores Stream 1, Rec. 2 stores Stream 2.
4. Check the boxes for the Overwrite older recordings option to specify which older
recordings can be overwritten once the available memory capacity has been used.
Recording 1 corresponds to Stream 1, Recording 2 corresponds to Stream 2.
CAUTION!
If older recordings are not allowed to be overwritten when the available memory capacity has
been used, the recording in question will be stopped. You can specify limitations for
overwriting old recordings by configuring the retention time (see Section 5.23 Advanced Mode:
Retention Time, page 52).
!
!
Formatting Storage Media
You can delete all recordings on a storage medium at any time.
CAUTION!
Check the recordings before deleting and back up important sequences on the computer's
hard drive.
1. Click a storage medium in the Managed storage media list to select it.
2. Click the Edit button below the list. A new window will open.
3. Click the Formatting button to delete all recordings in the storage medium.
4. Click OK to close the window.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
50 en | Configuration Using a Web Browser
VIP X1600 M4S
Deactivating Storage Media
You can deactivate any storage medium from the Managed storage media list. It is then no
longer used for recordings.
1. Click a storage medium in the Managed storage media list to select it.
2. Click the Remove button below the list. The storage medium is deactivated and removed
from the list.
5.22
Advanced Mode: Recording Profiles
You can define up to ten different recording profiles. You will then use these recording
profiles in the recording scheduler, where they are linked with the individual days and times
(see Section 5.24 Advanced Mode: Recording Scheduler, page 53).
NOTICE!
You can change or add to the recording profile description on the tabs on the Recording
Scheduler page (see Section Time periods, page 54).
1. Click one of the tabs to edit the corresponding profile.
2. In the table, click the name of the camera input for which you want to edit the settings.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
51
3. You can select multiple camera inputs by holding down the shift or [Ctrl] key as usual in
Windows. The following settings apply to all selected entries.
4. If necessary, click the Default button to return all settings to their default values.
5. Click the Copy Settings button if you want to copy the currently visible settings to other
profiles. A new window will open and you can select the profiles in which you want to
copy the settings.
6. For each profile, click the Set button to save the settings in the unit.
Standard recording
Here you can select the mode for standard recordings.
If you select Continuous, the recording proceeds continuously. If the maximum memory
capacity is reached, older recordings will automatically be overwritten. If you select the Pre-
alarm option, recording will only take place in the pre-alarm time, during the alarm and during
the set post-alarm time.
If you select Off, no automatic recording takes place.
CAUTION!
You can specify limitations for overwriting older recordings in Continuous mode by
configuring the retention time (see Section 5.23 Advanced Mode: Retention Time, page 52).
!
From this field, you can select the encoder profile to be used for recording (see
Section 5.19 Advanced Mode: Encoder Profile, page 44).
NOTICE!
The recording profile can deviate from the standard setting Active profile and is only used
during an active recording.
Pre-alarm time
You can select the required pre-alarm time from the list field.
Post-alarm time
You can select the required post-alarm time from the list field.
You can select the encoder profile to be used for recording during the post-alarm time (see
Section 5.19 Advanced Mode: Encoder Profile, page 44).
The Standard profile option adopts the selection at the top of the page.
Alarm input / Motion alarm / Video loss alarm
Here you can select the alarm sensor that is to trigger a recording.
The motion alarm is configured and activated on the VCA page (see Section 5.30 Advanced
The alarm inputs are configured and activated on the Alarm Inputs page (see
Section 5.34 Advanced Mode: Alarm Inputs, page 71).
The numbering of the checkboxes for the alarm inputs corresponds to the labeling of the
alarm inputs on the module.
Virtual alarm
Here you can select the virtual alarm sensors that are to trigger a recording, via RCP+
commands or alarm scripts, for example.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
52 en | Configuration Using a Web Browser
VIP X1600 M4S
NOTICE!
For more information, please see the Alarm Task Script Language document and the RCP+
documentation. These documents can be found on the product CD supplied with the
VIP X1600 XF base.
Recording includes
You can specify whether, in addition to video data, audio data and metadata (for example
alarms, VCA data and serial data) should also be recorded. Including metadata could make
subsequent searches of recordings easier but it requires additional memory capacity.
CAUTION!
Without metadata, it is not possible to include video content analysis in recordings.
!
5.23
Advanced Mode: Retention Time
You can specify the retention times for recordings. If the available memory capacity of a
medium has been used, older recordings are only overwritten if the retention time entered
here has expired.
NOTICE!
Make sure that the retention time corresponds with the available memory capacity. A rule of
thumb for the memory requirement is as follows: 1 GB per hour retention time with 4CIF for
complete frame rate and high image quality.
Retention Time
Enter the required retention time in hours or days for each recording. Recording 1
corresponds to Stream 1, Recording 2 corresponds to Stream 2.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
53
5.24
Advanced Mode: Recording Scheduler
The recording scheduler allows you to link the created recording profiles with the days and
times at which the cameras' images are to be recorded in the event of an alarm.
You can link any number of 15-minute intervals with the recording profiles for each day of the
week. Moving the mouse cursor over the table displays the time below it. This aids
orientation.
In addition to the normal weekdays, you can define holidays that are not in the standard
weekly schedule on which recordings are to apply. This allows you to apply a schedule for
Sundays to other days with dates that fall on varying weekdays.
1. Click the profile you want to link in the Time periods field.
2. Click in a field in the table, hold down the mouse button and drag the cursor over all the
periods to be assigned to the selected profile.
3. Use the right mouse button to deselect any of the intervals.
4. Click the Select All button to link all time intervals to the selected profile.
5. Click the Clear All button to deselect all of the intervals.
6. When you are finished, click the Set button to save the settings in the unit.
Holidays
You can define holidays that are not in the standard weekly schedule on which recordings are
to apply. This allows you to apply a schedule for Sundays to other days with dates that fall on
varying weekdays.
1. Click the Holidays tab. Any days that have already been selected will be shown in the
table.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
54 en | Configuration Using a Web Browser
VIP X1600 M4S
2. Click the Add button. A new window will open.
3. Select the desired date from the calendar. You can select several consecutive calendar
days by holding down the mouse button. These will later be displayed as a single entry in
the table.
4. Click OK to accept the selection. The window will close.
5. Assign the individual holidays to the recording profiles, as described above.
Deleting Holidays
You can delete holidays you have defined yourself at any time.
1. Click the Delete button. A new window will open.
2. Click the date you wish to delete.
3. Click OK. The item will be deleted from the table and the window will close.
4. The process must be repeated for deleting additional days.
Time periods
You can change the names of the recording profiles.
1. Click a profile and then the Rename button.
2. Enter your chosen name and then click the Rename button again.
Activating the Recording
After completing configuration you must activate the recording scheduler and start the
recording. Once recording is underway, the Recording Profiles and Recording Scheduler
pages are deactivated and the configuration cannot be modified.
You can stop the recording activity at any time and modify the settings.
1. Click the Start button to activate the recording scheduler.
2. Click the Stop button to deactivate the recording scheduler. Running recordings are
interrupted and the configuration can be changed.
Recording Status
The graphic indicates the recording activity of the module. You will see an animated graphic
while recording is taking place.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
55
5.25
Advanced Mode: Recording Status
Certain details on the recording status are displayed here for information purposes. You
cannot change any of these settings.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
56 en | Configuration Using a Web Browser
VIP X1600 M4S
5.26
Advanced Mode: Alarm Connections
You can select how the module responds to an alarm. In the event of an alarm, the unit can
automatically connect to a pre-defined IP address. You can enter up to ten IP addresses which
the module will select in order, until a connection is made.
Connect on alarm
Select On so that the module automatically connects to a pre-defined IP address in the event
of an alarm.
By setting Follows input 1 the unit maintains the connection that has been automatically
established for as long as an alarm exists on alarm input 1.
NOTICE!
In the default setting, Stream 2 is transmitted for alarm connections. Bear this fact in mind
when assigning the profile (see Section 5.19 Advanced Mode: Encoder Profile, page 44).
Number of destination IP address
Specify the numbers of the IP addresses to be contacted in the event of an alarm. The module
contacts the remote stations one after the other in the numbered sequence until a connection
is made.
Destination IP address
For each number, enter the corresponding IP address for the desired remote station.
Destination password
If the remote station is password protected, enter the password here.
In this page, you can save a maximum of ten destination IP addresses and hence up to ten
passwords for connecting to remote stations. If connections to more than ten remote stations
are to be possible, for example when initiating connections via higher-ranking systems such as
VIDOS or Bosch Video Management System, you can store a general password here. The
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
57
module can use this general password to connect to all remote stations protected with the
same password. In this case, proceed as follows:
1. Select 10 from the Number of destination IP address list field.
2. Enter the address 0.0.0.0 in the Destination IP address field.
3. Enter your chosen password in the Destination password field.
4. Define this password as the user password for all remote stations to which a connection
is to be possible.
NOTICE!
If you enter the destination IP address 0.0.0.0 for destination 10, this module address will no
longer be used for the tenth attempt at automatic connection in the event of an alarm. The
parameter is then used only to save the general password.
Video transmission
If the VIP X1600 XF is operated behind a firewall, TCP (HTTP port) should be selected as the
transfer protocol. For use in a local network, select UDP.
CAUTION!
Please note that in some circumstances, a larger bandwidth must be available on the network
for additional video images in the event of an alarm, in case Multicast operation is not
possible. To enable Multicast operation, select the UDP option for the Video transmission
parameter here and on the Network page (see Section Video transmission, page 75).
!
Remote port
Depending on the network configuration, select a browser port here. The ports for HTTPS
connections will be available only if the On option is selected in the SSL encryption
parameter.
Video output
If you know which unit is being used as the receiver, you can select the analog video output to
which the signal should be switched. If the destination unit is unknown, it is advisable to
select the First available option. In this case, the image is placed on the first free video
output. This is an output on which there is no signal. The connected monitor only displays
images when an alarm is triggered. If you select a particular video output and a split image is
set for this output on the receiver, you can also select from Decoder the decoder in the
receiver that is to be used to display the alarm image.
NOTICE!
Refer to the destination unit documentation concerning image display options and available
video outputs.
Decoder
Select a decoder of the receiver to display the alarm image. The decoder selected has an
impact on the position of the image in a split screen. For example, you can specify via a VIP XD
that the upper-right quadrant should be used to display the alarm image by selecting
decoder 2.
SSL encryption
The data for the connection, for example the password, can be securely transmitted with SSL
encryption. If you have selected the On option, only encrypted ports are offered in the
Remote port parameter.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
58 en | Configuration Using a Web Browser
VIP X1600 M4S
NOTICE!
Please note that the SSL encryption must be activated and configured at both ends of a
connection. This requires the appropriate certificates to be uploaded onto the module (see
Section Maintenance log, page 85).
You can activate and configure encryption of the media data (video, audio and metadata) on
the Encryption page (see Section 5.42 Advanced Mode: Encryption, page 83).
Auto-connect
Select the On option to automatically re-establish a connection to one of the previously
specified IP addresses after each reboot, after a connection breakdown or after a network
failure.
NOTICE!
In the default setting, Stream 2 is transmitted for automatic connections. Bear this fact in
mind when assigning the profile (see Section 5.19 Advanced Mode: Encoder Profile, page 44).
Audio
Select the On option if you wish to additionally transmit a standalone G.711 encoded audio
stream with alarm connections.
Default camera
Here you can select the camera whose image will be automatically displayed first on the
receiver when the alarm connection is made. Depending on the system configuration, the
receiver can then select the other cameras as well.
NOTICE!
The numbering follows the labeling of the video inputs on the actual unit.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
59
5.27
Advanced Mode: VCA
The VIP X1600 M4S encoder module contains an integrated video content analysis (VCA),
which can detect and analyze changes in the signal on the basis of image processing. Such
changes can be due to movements in the camera's field of view.
You can select various VCA configurations and adapt these to your application as required.
The Silent MOTION+ configuration is active by default. In this configuration, metadata is
created to facilitate searches of recordings; however, no alarm is triggered.
1. Click one of the tabs to open the configuration of the corresponding video input.
2. Select a VCA configuration and make the required settings.
3. If necessary, click the Default button to return all settings to their default values.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
60 en | Configuration Using a Web Browser
VIP X1600 M4S
5.28
Advanced Mode: VCA Profiles
You can configure two profiles with different VCA configurations. You can save profiles on
your computer's hard drive and load saved profiles from there. This can be useful if you want
to test a number of different configurations. Save a functioning configuration and test new
settings. You can use the saved configuration to restore the original settings at any time.
NOTICE!
If computing power becomes short, the highest priority is always the live images and
observe the processor load and optimize the encoder settings or the video content analysis
settings as necessary (see Section 8.5 Processor Load, page 107).
1. Select a VCA profile and enter the required settings.
2. If necessary, click the Default button to return all settings to their default values.
3. Click the Save... button to save the profile settings to another file. A new window is
opened, in which you can specify where you want to save the file and what name you
want to save it under.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
61
4. Click the Load... button to load a saved profile. A new window opens in which you can
select the profile file and specify where to save the file.
VCA configuration
Select one of the profiles here to activate it or edit it.
You can rename the profile.
1. To rename the file, click the icon to the right of the list field and enter the new profile
name in the field.
2. Click the icon again. The new profile name is saved.
Alarm status
The alarm status is displayed here for information purposes. This means you can check the
effects of your settings immediately.
Analysis type
Select the required analysis algorithm. By default, only MOTION+ is available – this offers a
motion detector and essential recognition of tampering.
NOTICE!
Additional analysis algorithms with comprehensive functions such as IVMD and IVA are
available from Bosch Security Systems.
If you select one of these algorithms, you can set the corresponding parameters here directly.
You can find information on this in the relevant documents on the product CD supplied.
Metadata is always created for a video content analysis, unless this was explicitly excluded.
Depending on the analysis type selected and the relevant configuration, additional
information overlays the video image in the preview window next to the parameter settings.
With the MOTION+ analysis type, for example, the sensor fields in which motion is recorded
will be marked with rectangles.
NOTICE!
On the LIVEPAGE Functions page, you can also enable additional information overlays for the
LIVEPAGE (see Section 5.15 Advanced Mode: LIVEPAGE Functions, page 40).
Motion detector (MOTION+ only)
For the detector to function, the following conditions must be met:
–
–
–
Analysis must be activated.
At least one sensor field must be activated.
The individual parameters must be configured to suit the operating environment and the
desired responses.
–
The sensitivity must be set to a value greater than zero.
CAUTION!
Reflections of light (off glass surfaces, etc.), switching lights on or off or changes in the light
level caused by cloud movement on a sunny day can trigger unintended responses from the
motion detector and generate false alarms. Run a series of tests at different times of the day
and night to ensure that the video sensor is operating as intended.
!
For indoor surveillance, ensure constant lighting of the areas during the day and at night.
Sensitivity (MOTION+ only)
The basic sensitivity of the motion detector can be adjusted for the environmental conditions
to which the camera is subject.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
62 en | Configuration Using a Web Browser
VIP X1600 M4S
The sensor reacts to variations in the brightness of the video image. The darker the
observation area, the higher the value that must be selected.
Minimum object size (MOTION+ only)
You can specify the number of sensor fields that a moving object must cover to generate an
alarm. This is to prevent objects that are too small from triggering an alarm.
A minimum value of 4 is recommended. This value corresponds to four sensor fields.
Select Area (MOTION+ only)
The areas of the image to be monitored by the motion detector can be selected. The video
image is subdivided into 858 square fields. Each of these fields can be activated or
deactivated individually. If you wish to exclude particular regions of the camera's field of view
from monitoring due to continuous movement (by a tree in the wind, etc.), the relevant fields
can be deactivated.
1. Click Select Area to configure the sensor fields. A new window will open.
2. If necessary, click Clear All first to clear the current selection (fields marked yellow).
3. Left-click the fields to be activated. Activated fields are marked yellow.
4. If necessary, click Select All to select the entire video frame for monitoring.
5. Right-click any fields you wish to deactivate.
6. Click OK to save the configuration.
7. Click the close button X in the window title bar to close the window without saving the
changes.
Tamper detection
You can reveal the tampering of cameras and video cables by means of various options. Run a
series of tests at different times of the day and night to ensure that the video sensor is
operating as intended.
NOTICE!
The options for tamper detection can only be set for fixed cameras. Dome cameras or other
motorized cameras cannot be protected in this manner as the movement of the camera itself
causes changes in the video image that are too great.
Sensitivity
NOTICE!
This and the following parameter are only accessible if the reference check is activated.
The basic sensitivity of the tamper detection can be adjusted for the environmental conditions
to which the camera is subject.
The algorithm reacts to the differences between the reference image and the current video
image. The darker the observation area, the higher the value that must be selected.
Trigger delay (s)
You can set delayed alarm triggering. The alarm is only triggered after a set time interval in
seconds has elapsed and then only if the triggering condition still exists. If the original
condition has been restored before this time interval elapses, the alarm is not triggered. This
allows you to avoid false alarms triggered by short-term changes, for example cleaning
activities in the direct field of vision of the camera.
Global change
You can set how large the global change in the video image must be for an alarm to be
triggered. This setting is independent of the sensor fields selected under Select Area. Set a
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
63
high value if fewer sensor fields need to change to trigger an alarm. With a low value, it is
necessary for changes to occur simultaneously in a large number of sensor fields to trigger an
alarm.
This option allows you to detect, independently of motion alarms, manipulation of the
orientation or location of a camera resulting from turning the camera mount bracket, for
instance.
Global change
Activate this function if the global change, as set with the Global change slide control, should
trigger an alarm.
Scene too bright
Activate this function if tampering associated with exposure to extreme light (for instance,
shining a flashlight directly on the objective) should trigger an alarm. The average brightness
of the scene provides a basis for recognition.
Scene too dark
Activate this function if tampering associated with covering the lens (for instance, by spraying
paint on it) should trigger an alarm. The average brightness of the scene provides a basis for
recognition.
Scene too noisy
Activate this function if tampering associated with EMC interference (noisy scene as the result
of a strong interference signal in the vicinity of the video lines), as an example, should trigger
an alarm.
Reference check
You can save a reference image that is continuously compared with the current video image. If
the current video image in the marked areas differs from the reference image, an alarm is
triggered. This allows you to detect tampering that would otherwise not be detected, for
example if the camera is turned.
1. Click Reference to save the currently visible video image as a reference.
2. Click Select Area and select the areas in the reference image that are to be monitored.
3. Check the box Reference check to activate on-going matching. The stored reference
image is displayed in black and white below the current video image, and the selected
areas are marked in yellow.
4. Select the Disappearing edges or Appearing edges option to specify the reference check
once again.
Select Area
You can select the image areas in the reference image that are to be monitored. The video
image is subdivided into 858 square fields. Each of these fields can be activated or
deactivated individually.
NOTICE!
Select only those areas for reference monitoring in which no movement takes place and that
are always evenly lit, as false alarms could otherwise be triggered.
1. Click Select Area to configure the sensor fields. A new window will open.
2. If necessary, click Clear All first to clear the current selection (fields marked yellow).
3. Left-click the fields to be activated. Activated fields are marked yellow.
4. If necessary, click Select All to select the entire video frame for monitoring.
5. Right-click any fields you wish to deactivate.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
64 en | Configuration Using a Web Browser
VIP X1600 M4S
6. Click OK to save the configuration.
7. Click the close button X in the window title bar to close the window without saving the
changes.
5.29
Advanced Mode: VCA Scheduled
This configuration allows you to link the created VCA profile with the days and times at which
the video content analysis is to be active.
You can link any number of 15-minute intervals with the VCA profiles for each day of the week.
Moving the mouse cursor over the table displays the time below it. This aids orientation.
In addition to the normal weekdays, you can define holidays that are not in the standard
weekly schedule on which recordings are to apply. This allows you to apply a schedule for
Sundays to other days with dates that fall on varying weekdays.
1. Click the profile you want to link in the Time periods field.
2. Click in a field in the table, hold down the mouse button and drag the cursor over all the
periods to be assigned to the selected profile.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
65
3. Use the right mouse button to deselect any of the intervals.
4. Click the Select All button to link all time intervals to the selected profile.
5. Click the Clear All button to deselect all of the intervals.
6. When you are finished, click the Set button to save the settings in the unit.
Holidays
You can define holidays on which a profile should be active that are different to the standard
weekly schedule. This allows you to apply a schedule for Sundays to other days with dates
that fall on varying weekdays.
1. Click the Holidays tab. Any days that have already been selected will be shown in the
table.
2. Click the Add button. A new window will open.
3. Select the desired date from the calendar. You can select several consecutive calendar
days by holding down the mouse button. These will later be displayed as a single entry in
the table.
4. Click OK to accept the selection. The window will close.
5. Assign the individual holidays to the VCA profiles, as described above.
Deleting Holidays
You can delete holidays you have defined yourself at any time.
1. Click the Delete button. A new window will open.
2. Click the date you wish to delete.
3. Click OK. The item will be deleted from the table and the window will close.
4. The process must be repeated for deleting additional days.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
66 en | Configuration Using a Web Browser
VIP X1600 M4S
5.30
Advanced Mode: VCA Event Triggered
This configuration allows you stipulate that the video content analysis is only to be activated
when triggered by an event. As long as no trigger is activated, the Silent MOTION+
configuration in which metadata is created is active; this metadata facilitates searches of
recordings, but does not trigger an alarm.
Trigger
You can select one of the physical alarms on the device's alarm inputs or one of the virtual
alarms as a trigger. A virtual alarm is created using software, with RCP+ commands or alarm
scripts, for example.
NOTICE!
For more information, please see the Alarm Task Script Language document and the RCP+
documentation. These documents can be found on the product CD supplied with the
VIP X1600 XF base.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
67
Trigger active
Select the VCA configuration here that is to be enabled via an active trigger. A green check
mark to the right of the list field indicates that the trigger is active.
Trigger inactive
Select the VCA configuration here that is to be activated if the trigger is not active. A green
check mark to the right of the list field indicates that the trigger is inactive.
Delay (s)
Select the delay period here for the reaction of the video content analysis to trigger signals. A
delay period may be useful in avoiding false alarms or frequent triggering, for example. During
the delay period, the Silent MOTION+ configuration is always enabled.
5.31
Advanced Mode: Audio Alarm
The module can create alarms on the basis of audio signals. You can configure signal strengths
and frequency ranges in such a way that false alarms, for example due to machine noise or
background noise, are avoided. Configure the required settings for each audio input.
First set up normal audio transmission before you configure the audio alarm here (see
Section 5.20 Advanced Mode: Audio (Audio Version Only), page 47).
Audio alarm
Select On if you want the unit to generate audio alarms from the input in question.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
68 en | Configuration Using a Web Browser
VIP X1600 M4S
Name
The name makes it easier to identify the alarm in extensive video monitoring systems, for
example with the VIDOS and Bosch Video Management System programs. Enter a unique and
clear name here.
CAUTION!
Do not use any special characters, for example &, in the name.
Special characters are not supported by the system's internal recording management and may
therefore result in the Player or Archive Player being unable to play back the recording.
!
Threshold
Set up the threshold on the basis of the signal visible in the graphic You can set the threshold
using the slide control or, alternatively, you can move the white line directly in the graphic
using the mouse.
Sensitivity
You can use this setting to adapt the sensitivity to the sound environment. You can effectively
suppress individual signal peaks. A high value represents a high level of sensitivity.
Signal Ranges
You can exclude particular signal ranges in order to avoid false alarms. For this reason the
total signal is divided into 13 tonal ranges (mel scale). Check or uncheck the boxes below the
graphic to include or exclude individual ranges.
5.32
Advanced Mode: Alarm E-Mail
As an alternative to automatic connecting, alarm states can also be documented by e-mail. In
this way it is possible to notify a recipient who does not have a video receiver. In this case the
module automatically sends an e-mail to a previously defined e-mail address.
Send alarm e-mail
Select On if you want the module to automatically send an alarm e-mail in the event of an
alarm.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
69
Mail server IP address
Enter the IP address of a mail server that operates on the SMTP standard (Simple Mail
Transfer Protocol). Outgoing e-mails are sent to the mail server via the address you entered.
Otherwise leave the box blank (0.0.0.0).
SMTP user name
Enter a registered user name for the chosen mailserver here.
SMTP password
Enter the required password for the registered user name here.
Format
You can select the data format of the alarm message.
–
–
Standard (with JPEG)
E-mail with attached JPEG image file.
SMS
E-mail in SMS format to an e-mail-to-SMS gateway (for example to send an alarm by
cellphone) without an image attachment.
CAUTION!
When a cellphone is used as the receiver, make sure to activate the e-mail or SMS function,
depending on the format, so that these messages can be received.
You can obtain information on operating your cellphone from your cellphone provider.
!
Attach JPEG from camera
Click the checkbox to specify that JPEG images are sent from the camera in question. An
enabled video input is indicated by a check mark.
Destination address
Enter the e-mail address for alarm e-mails here. The maximum address length is 49
characters.
Sender name
Enter a unique name for the e-mail sender, for example the location of the unit. This will make
it easier to identify the origin of the e-mail.
Test e-mail
You can test the e-mail function by clicking the Send Now button. An alarm e-mail is
immediately created and sent.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
70 en | Configuration Using a Web Browser
VIP X1600 M4S
5.33
Advanced Mode: Alarm Task Editor
CAUTION!
Editing scripts on this page overwrites all settings and entries on the other alarm pages. This
procedure cannot be reversed.
In order to edit this page, you must have programming knowledge and be familiar with the
information in the Alarm Task Script Language document. The document is located on the
product CD supplied with the VIP X1600 XF base.
!
As an alternative to the alarm settings on the various alarm pages, you can enter your desired
alarm functions in script form here. This will overwrite all settings and entries on the other
alarm pages.
1. Click the Examples link under the Alarm Task Editor field to see some script examples. A
new window will open.
2. Enter new scripts in the Alarm Task Editor field or change existing scripts in line with
your requirements.
3. When you are finished, click the Set button to transmit the scripts to the unit. If the
transfer was successful, the message Script successfully parsed is displayed over the
text field. If it was not successful, an error message will be displayed with further
information.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
71
5.34
Advanced Mode: Alarm Inputs
You can configure the alarm inputs for the module.
Alarm input
Select Active high if the alarm is to be triggered when the contact closes. Select Active low if
the alarm is to be triggered when the contact opens.
Name
You can enter a name for each alarm input, which is then displayed below the icon for the
alarm input on the LIVEPAGE if configured correctly (see Section 5.15 Advanced Mode:
LIVEPAGE Functions, page 40).
5.35
Advanced Mode: Relay
You can configure the switching behavior of the relay outputs. For each relay, you can specify
an open switch relay (normally closed contact) or a closed switch relay (normally open
contact).
You can also specify whether an output should operate as a bistable or monostable relay. In
bistable mode, the triggered state of the relay is maintained. In monostable mode, you can set
the time after which the relay will return to the idle state.
You can select different events that automatically activate an output. It is possible, for
example, to turn on a floodlight by triggering a motion alarm and then turning the light off
again when the alarm has stopped.
Idle state
Select Open if you want the relay to operate as an NO contact, or select Closed if the relay is
to operate as an NC contact.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
72 en | Configuration Using a Web Browser
VIP X1600 M4S
Operating mode
Select an operating mode for the relay.
For example, if you want an alarm-activated lamp to stay on after the alarm ends, select
Bistable. If you wish an alarm-activated siren to sound for ten seconds, for example, select
10 s.
Relay follows
If required, select a specific event that will trigger the relay. The following events are possible
triggers:
–
–
–
Off
Relay is not triggered by events
Connection
Trigger whenever a connection is made
Video alarm
Trigger by interruption of the video signal at the corresponding input
Trigger by motion alarm at the corresponding input, as configured on the VCA page (see
Section 5.30 Advanced Mode: VCA Event Triggered, page 66)
Local input
–
–
Trigger by the corresponding external alarm input
Remote input
Trigger by remote station's corresponding switching contact (only if a connection exists)
NOTICE!
The numbers in the lists of selectable events relate to the corresponding connections on the
unit, Video alarm 1, for example to the Video In 1 connection.
Relay name
You can assign a name for the relay here. The name is shown on the button next to Trigger
relay. The Livepage can also be configured to display the name under the relay icon.
Trigger relay
Click the button to trigger the relay manually (for testing or to operate a door opener, for
example).
5.36
Advanced Mode: COM1
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
73
You can configure the serial interface parameters (orange terminal block) to meet your
requirements.
If the module is working in multicast mode (see Section 5.40 Advanced Mode: Multicasting,
page 81), the first remote location to establish a video connection to the unit is also assigned
the transparent data connection. However, after about 15 seconds of inactivity the data
connection is automatically terminated and another remote location can exchange
transparent data with the unit.
Serial port function
Select a controllable unit from the list. If you wish to use the serial port to transmit
transparent data, select Transparent. Select Terminal if you wish to operate the unit from a
terminal.
NOTICE!
After selecting a unit, the remaining parameters in the window are set automatically and
should not be changed.
Camera ID
If necessary, enter the ID of the peripheral you wish to control (for example a dome camera or
pan/tilt head).
Baud rate
Select the value for the transmission rate in bps.
Data bits
The number of data bits per character cannot be changed.
Stop bits
Select the number of stop bits per character.
Parity check
Select the type of parity check.
Interface mode
Select the desired protocol for the serial interface.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
74 en | Configuration Using a Web Browser
VIP X1600 M4S
5.37
Advanced Mode: Network
The settings in this screen are used to integrate the module into an existing network.
Some changes only take effect after the unit is rebooted. In this case, the Set button changes
to Set and Reboot.
1. Make the desired changes.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
75
2. Click the Set and Reboot button. The module is rebooted and the changed settings are
activated.
CAUTION!
If you change the IP address, subnet mask or gateway address, the module is only available
under the new addresses after the reboot.
!
Automatic IP assignment
If a DHCP server is employed in the network for the dynamic assignment of IP addresses, you
can activate acceptance of IP addresses automatically assigned to the module.
Certain applications (VIDOS, Bosch Video Management System, Archive Player, Configuration
Manager) use the IP address for the unique assignment of the unit. If you use these
applications, the DHCP server must support the fixed assignment between IP address and
MAC address, and must be appropriately set up so that, once an IP address is assigned, it is
retained each time the system is rebooted.
IP address
Enter the desired IP address for the module. The IP address must be valid for the network.
Subnet mask
Enter the appropriate subnet mask for the selected IP address here.
Gateway address
If you want the module to establish a connection to a remote location in a different subnet,
enter the IP address of the gateway here. Otherwise leave the box blank (0.0.0.0).
DNS server address
Using a DNS server, the device can resolve an address indicated as a name. Enter the IP
address of the DNS server here.
Video transmission
If the VIP X1600 XF is operated behind a firewall, TCP (HTTP port) should be selected as the
transfer protocol. For use in a local network, select UDP.
CAUTION!
Multicast operation is only possible with the UDP protocol. The TCP protocol does not
support multicast connections.
!
The MTU value in UDP mode is 1,514 bytes.
HTTP browser port
Select a different HTTP browser port from the list if required. The default HTTP port is 80. If
you want to allow only secure connections via HTTPS, you must deactivate the HTTP port. In
this case, select Off.
HTTPS browser port
If you wish to allow browser access on the network via a secure connection, select an HTTPS
browser port from the list if necessary. The default HTTPS port is 443. Select the Off option
to deactivate HTTPS ports; only unsecured connections will now be possible.
The module uses the TLS 1.0 encryption protocol. You may have to activate this protocol via
your browser configuration. You must also activate the protocol for the Java applications (via
the Java control panel in the Windows control panel).
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
76 en | Configuration Using a Web Browser
VIP X1600 M4S
NOTICE!
If you want to allow only secure connections with SSL encryption, you must select the Off
option for each of the parameters HTTP browser port, RCP+ port 1756 and Telnet support.
This deactivates all unsecured connections. Connections will then only be possible via the
HTTPS port.
You can activate and configure encryption of the media data (video, audio and metadata) on
the Encryption page (see Section 5.42 Advanced Mode: Encryption, page 83).
RCP+ port 1756
To exchange connection data, you can activate the unsecured RCP+ port 1756. If you want
connection data to be transmitted only when encrypted, select the Off option to deactivate
the port.
Telnet support
If you want to allow only secure connections with encrypted data transmission, you must
select the Off option to deactivate Telnet support. The unit will then no longer be accessible
using the Telnet protocol.
Interface mode ETH 1/ETH 2/ETH 3 (only for the module in Slot 1)
If required, select the Ethernet link type for the ETH 1, ETH 2 and ETH 3 interfaces on the
VIP X1600 XF. Depending on the unit connected, it may be necessary to select a special
operation type. These settings can only be configured for the module in Slot 1.
Network MSS (Byte)
You can set the maximum segment size for the IP packet's user data. This gives you the option
to adjust the size of the data packets to the network environment and to optimize data
transmission. Please comply with the MTU value of 1,514 bytes in UDP mode.
iSCSI MSS (Byte)
You can specify a higher MSS value for a connection to the iSCSI system than for the other
data traffic via the network. The potential value depends on the network structure. A higher
value is only useful if the iSCSI system is located in the same subnet as the VIP X1600 XF.
Enable DynDNS
DynDNS.org is a DNS hosting service that stores IP addresses in a database ready for use. It
allows you to select the module via the Internet using a host name, without having to know
the current IP address of the unit. You can enable this service here. To do this, you must have
an account with DynDNS.org and you must have registered the required host name for the
unit on that site.
NOTICE!
Information about the service, registration process and available host names can be found at
DynDNS.org.
Host name
Enter the host name registered on DynDNS.org for the module here.
User name
Enter the user name you registered at DynDNS.org here.
Password
Enter the password you registered at DynDNS.org here.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
77
Force registration now
You can force the registration by transferring the IP address to the DynDNS server. Entries
that change frequently are not provided in the Domain Name System. It is a good idea to force
the registration when you are setting up the device for the first time. Only use this function
when necessary and no more than once a day, to avoid the possibility of being blocked by the
service provider. To transfer the IP address of the module, click the Register button.
Status
The status of the DynDNS function is displayed here for information purposes. You cannot
change any of these settings.
5.38
Advanced Mode: Advanced
The settings on this page are used to implement advanced settings for the network.
Some changes only take effect after the unit is rebooted. In this case, the Set button changes
to Set and Reboot.
1. Make the desired changes.
2. Click the Set and Reboot button. The module is rebooted and the changed settings are
activated.
SNMP
The module supports the SNMP V2 (Simple Network Management Protocol) for managing and
monitoring network components, and can send SNMP messages (traps) to IP addresses. The
unit supports SNMP MIB II in the unified code. If you wish to send SNMP traps, enter the IP
addresses of one or two required target devices here.
If you select On for the SNMP parameter and do not enter an SNMP host address, the module
does not send them automatically, but only replies to SNMP requests. If you enter one or two
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
78 en | Configuration Using a Web Browser
VIP X1600 M4S
SNMP host addresses, SNMP traps are sent automatically. Select Off to deactivate the SNMP
function.
1. SNMP host address / 2. SNMP host address
If you wish to send SNMP traps automatically, enter the IP addresses of one or two required
target units here.
SNMP traps
You can select which traps are to be sent.
1. Click Select. A list is opened.
2. Click the checkboxes to select the required traps. All the checked traps will be sent.
3. Click Set to accept the selection.
Authentication (only for the module in Slot 1)
If a RADIUS server is employed in the network for managing access rights, authentication
must be activated here to allow communication with the unit. The RADIUS server must also
contain the corresponding data.
To configure the unit, you must connect the VIP X1600 XF directly to a computer using a
network cable. This is because communication via the network is not enabled until the
Identity and Password parameters have been set and successfully authenticated.
CAUTION!
The switch used for the network must support the multi-host operation when using 802.1x
authentication and must be configured so that a VIP X1600 XF with several modules can try
several hosts for communicating over the network.
!
Identity (only for the module in Slot 1)
Enter the name that the RADIUS server is to use for identifying the VIP X1600 XF.
Password (only for the module in Slot 1)
Enter the password that is stored in the RADIUS server.
RTSP port
If necessary, select a different port for the exchange of the RTSP data from the list. The
standard RTSP port is 554. Select Off to deactivate the RTSP function.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
79
5.39
Advanced Mode: Switch Configuration
The parameters on this page can be used to configure the switch integrated into VIP X1600 XF
and adapt it to the network. If several Ethernet interfaces of the VIP X1600 XF are connected
with the network, you can use different protocols to optimize data transfer. Detailed
knowledge of the network in which the VIP X1600 XF is located is essential in order to
configure the parameters on this page.
NOTICE!
The parameters for switch configuration can only be changed for the module in Slot 1. This
page cannot be viewed for modules in Slots 2 and 4.
Operating mode
Select the required operating mode for the switch. The operating mode is used to determine
the communication protocol.
Static port trunking enables increased data transfer by bundling Ethernet interfaces.
Through a process of continuous checking, the RSTP (Rapid Spanning Tree Protocol)
determines the fastest possible route for data packets in the network. Other parameters are
used to define detailed settings.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
80 en | Configuration Using a Web Browser
VIP X1600 M4S
The LACP (Link Aggregation Control Protocol) routes the Ethernet interfaces through the
network together on the basis of the route determined by RSTP. There are therefore further
settings that apply to the RSTP.
Version
Here you are required to select the current protocol (RSTP) or the compatibility mode for the
older version (STP compatible), depending on which is supported by the devices available in
the network.
Priority
Select the required priority for the switch. Selection is carried out in steps with increments of
4096. The smallest, and therefore the most important, priority is 0. The lower the priority, the
greater precedence it is accorded in its route through the network.
Hello time (s)
Select the required Hello time here. In the interval specified here, the switch sends a message
to other network components stating its availability (alive message). If this message fails, the
network reorganizes itself.
Max age (s)
The maximum age describes the time during which the route information is still valid.
Forward delay (s)
The forward delay defines the period during which the unit is in recording status before
information can be forwarded. When starting up the unit, this is the time until the first
information retrieval in the network.
Enable RSTP
Select the VIP X1600 XF Ethernet interfaces to which RSTP is to be applied.
Enable RSTP/LACP
Select the VIP X1600 XF Ethernet interfaces to which RSTP and LACP are to be applied.
Edge port
Select the VIP X1600 XF Ethernet interfaces that are to be identified as the end points of an
RSTP chain.
Path costs
One way of prioritizing within the network is to define path costs. As required, define
different path costs for each Ethernet interface of the VIP X1600 XF. The path costs are used
for the evaluation of the data transfer routes.
LACP key
The LACP key is an identifier for using the interface and must be compatible with the setting
on the network switch. Only interfaces with the same key are used for bundling.
IGMP snooping
If you activate IGMP snooping, the switch assigns the multicast data traffic to the relevant
interfaces. This function can reduce data traffic in the network as well as within the individual
modules, and can respond when the network is overloaded, particularly when numerous
VIP X1600 XF modules are switched in quick succession.
Enable IGMP querier
You can enable the IGMP querier; this defines the VIP X1600 XF switch as the central
administrator of multicast data traffic in the network. If the VIP X1600 XF is located in an
installation that is some distance away, in which the multicast data is also needed, then this
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
81
option can be useful if the connection to the central unit is lost. Once activation is complete,
you must enter the required IP address.
IGMP source IP
Enter the IP address that you want to use here. The IP address that you use should be as high
as possible and at least higher than that of the standard IGMP querier.
5.40
Advanced Mode: Multicasting
In addition to a 1:1 connection between an encoder and a single receiver (unicast), the
module can enable multiple receivers to receive the video signal from an encoder
simultaneously. The device either duplicates the data stream itself and then distributes it to
multiple receivers (Multi-unicast) or it sends a single data stream to the network, where the
data stream is simultaneously distributed to multiple receivers in a defined group (Multicast).
For each encoder (video input) you can enter a dedicated multicast address and port for each
stream. You can switch between the streams by clicking the appropriate tabs.
NOTICE!
Multicast operation requires a multicast-enabled network that uses the UDP and the Internet
Group Management IGMP protocols. Other group management protocols are not supported.
The TCP protocol does not support multicast connections.
A special IP address (class D address) must be configured for multicast operation in a
multicast-enabled network.
The network must support group IP addresses and the Internet Group Management Protocol
(IGMP V2). The address range is from 225.0.0.0 to 239.255.255.255.
The multicast address can be the same for multiple streams. However, it will be necessary to
use a different port in each case so that multiple data streams are not sent simultaneously
using the same port and multicast address.
NOTICE!
You must set the parameters for each encoder (video input) and for each stream individually.
The numbering follows the labeling of the video inputs on the actual unit.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
82 en | Configuration Using a Web Browser
VIP X1600 M4S
Enable
To enable simultaneous data reception on several receivers you need to activate the multicast
function. To do this, check the box. You can then enter the multicast address.
Multicast address
Enter a valid multicast address for each stream from the relevant encoder (video input) to be
operated in multicast mode (duplication of the data streams in the network).
With the setting 0.0.0.0 the encoder for the relevant stream operates in multi-unicast mode
(copying of data streams in the unit). The module supports multi-unicast connections for up
to five simultaneously connected receivers.
NOTICE!
Duplication of data places a heavy demand on the module and can lead to impairment of the
image quality under certain circumstances.
Port
Assign a different port to each data stream if there are simultaneous data streams at the same
multicast address.
Enter the port address of the required stream here.
Streaming
Click the checkbox to activate multicast streaming mode for the relevant stream. An enabled
stream is indicated by a check mark.
Multicast packet TTL
You can enter a value to specify how long the multicast data packets are active on the
network. This value must be greater than one if multicast is to be run via a router.
5.41
Advanced Mode: JPEG Posting
You can save individual JPEG images on an FTP server at specific intervals. You can then
retrieve these images at a later date to reconstruct alarm events if required.
Image size
Select the resolution you wish the JPEG images to have:
–
Small
176 × 144/120 pixels (QCIF)
DOC | V4.0 | 2009.06
Installation and Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Bosch Security Systems
VIP X1600 M4S
Configuration Using a Web Browser | en
83
–
–
Medium
352 × 288/240 pixels (CIF)
Large
704 × 576/480 pixels (4CIF)
File name
You can select how file names will be created for the individual images that are transmitted.
–
–
–
Overwrite
The same file name is always used and any existing file will be overwritten with the
current file.
Increment
A number from 000 to 255 is added to the file name and automatically incremented by 1.
When it reaches 255 it starts again from 000.
Date/time suffix
The date and time are automatically added to the file name. When setting this parameter,
ensure that the unit's date and time are always correctly set. Example: the file
snap011005_114530.jpg was stored on October 1, 2005 at 11:45 and 30 seconds.
Posting interval
Enter the interval in seconds at which the images will be sent to an FTP server. Enter zero if
you do not want any images to be sent.
FTP server IP address
Enter the IP address of the FTP server on which you wish to save the JPEG images.
FTP server login
Enter your login name for the FTP server.
FTP server password
Enter the password that gives you access to the FTP server.
Path on FTP server
Enter the exact path on which you wish to post the images on the FTP server.
Post JPEG from camera
Click the checkbox to select the cameras from which JPEG images are sent. An enabled video
input is indicated by a check mark.
NOTICE!
The creation of JPEG images has a lower priority than video encoding and image analysis. This
can result in JPEG images being created with a delay of up to several seconds after the
triggering event. If reliable, real-time recording of the alarm is required, ensure that the
encoder has enough computing power available.
5.42
Advanced Mode: Encryption
A special license, with which you will receive a corresponding activation key, is required to
encrypt user data. You can enter the activation key to release the function on the Licenses
page (see Section 5.44 Advanced Mode: Licenses, page 86).
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
84 en | Configuration Using a Web Browser
VIP X1600 M4S
5.43
Advanced Mode: Maintenance
Firmware
The module is designed in such a way that its functions and parameters can be updated with
firmware. To do this, transfer the current firmware package to the unit via the selected
network. It will then be automatically installed there.
In this way, a module can be serviced and updated remotely without a technician having to
change the installation on site.
You obtain the current firmware from your customer service or from the download area at
www.boschsecurity.com.
CAUTION!
Before launching the firmware upload make sure that you have selected the correct upload
file. Uploading the wrong files can result in the unit no longer being addressable, in which
case you must replace the unit.
You should never interrupt the installation of firmware. An interruption can lead to the flash-
EPROM being incorrectly programmed. This in turn can result in the unit no longer being
addressable, in which case it will have to be replaced. Even changing to another page or
closing the browser window leads to an interruption.
!
1. First store the firmware file on your hard drive.
2. Enter the full path of the firmware file in the field or click Browse to locate and select the
file.
3. Next, click Upload to begin transferring the file to the unit. The progress bar allows you
to monitor the transfer.
The new firmware is unpacked and the Flash EPROM is reprogrammed. The time remaining is
shown by the message going to reset Reconnecting in ... seconds. The unit reboots
automatically once the upload has successfully completed.
If the Connect LED lights up red, the upload has failed and must be repeated. To perform the
upload you must now switch to a special page:
1. In the address bar of your browser, enter /main.htm after the IP address of the module
(for example 192.168.0.16/main.htm).
2. Repeat the upload.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
85
Configuration
You can save configuration data for the module on a computer and then load saved
configuration data from a computer to the module.
Upload
1. Enter the full path of the file to upload or click Browse to select the required file.
2. Make certain that the file to be loaded comes from the same unit type as the unit you
want to configure.
3. Next, click Upload to begin transferring the file to the unit. The progress bar allows you
to monitor the transfer.
Once the upload is complete, the new configuration is activated. The time remaining is shown
by the message going to reset Reconnecting in ... seconds. The unit reboots automatically
once the upload has successfully completed.
Download
1. Click the Download button. A dialog box opens.
2. Follow the on-screen instructions to save the current settings.
SSL certificate
To be able to work with an SSL encrypted data connection, both ends of a connection must
hold the relevant certificates. You can upload the SSL certificate, comprising one or multiple
files, onto the module.
If you wish to upload multiple files onto the module, you must select them consecutively.
NOTICE!
The certificate must be created in the format *.pem so that it can be accepted by the unit.
1. Enter the full path of the file to upload or click Browse to select the required file.
2. Next, click Upload to begin transferring the file to the unit.
3. Once all files have been successfully uploaded, the unit must be rebooted. In the address
field of your browser, enter /reset after the IP address of the module (for example
192.168.0.16/reset).
The new SSL certificate is valid.
Maintenance log
You can download an internal maintenance log from the module to send it to Customer
Service for support purposes. Click Download and select a storage location for the file.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
86 en | Configuration Using a Web Browser
VIP X1600 M4S
5.44
Advanced Mode: Licenses
You can enter the activation key to release additional functions or software modules.
NOTICE!
The activation key cannot be deactivated again and is not transferable to other units.
5.45
Advanced Mode: System Status
Information about the status of the fans and the power supply is displayed in this window.
NOTICE!
This page is only visible for the module in Slot 1.
Check power redundancy
Select the option On if the VIP X1600 XF is to be supplied by two power supply units. This
selection is important for displaying the power supply status messages correctly.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Configuration Using a Web Browser | en
87
5.46
Advanced Mode: System Overview
The data on this page are for information purposes only and cannot be changed. Keep a
record of these numbers in case technical assistance is required.
NOTICE!
You can select all required text on this page with the mouse and copy it to the clipboard with
the [Ctrl]+[C] key combination, for example if you want to send it via e-mail.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
88 en | Configuration Using a Web Browser
VIP X1600 M4S
5.47
Function Test
The VIP X1600 M4S encoder module offers a range of configuration options. You should
therefore check that it is functioning correctly after installation and configuration.
The function test is the only way to ensure that the module operates as expected in the event
of an alarm.
Your check should include the following functions:
–
–
–
–
–
Can the module be called up remotely?
Is all the required data transferred?
Does the module react to alarm events as required?
Do the recordings occur as intended?
Is it possible to control peripherals if necessary?
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Operation | en
89
6
Operation
6.1
Operation with Microsoft Internet Explorer
A computer with Microsoft Internet Explorer (version 6.0 or higher) can receive live images
from the VIP X1600 M4S encoder module, control cameras or other peripherals and replay
stored video sequences.
System Requirements
–
–
–
–
–
–
–
Computer with Windows XP or Windows Vista operating system
Network access (Intranet or Internet)
Microsoft Internet Explorer (version 6.0 or higher)
Screen resolution 1,024 × 768 pixels
16- or 32-bit color depth
Installed Sun JVM
For playing back recordings: connection to storage medium
NOTICE!
Please note the information in the System Requirements document on the product CD
supplied with the VIP X1600 XF base. If necessary, you can install the required programs and
controls from the product CD.
The Web browser must be configured to enable Cookies to be set from the IP address of the
unit.
Under Windows Vista, the protected mode on the Security tab under Internet Options must
be deactivated.
You can find notes on using Microsoft Internet Explorer in the online Help in Internet Explorer.
Installing MPEG ActiveX
Suitable MPEG ActiveX software must be installed on the computer to allow the live video
images to be played back. If necessary, you can install the program from the product CD.
1. Insert the product CD into the computer's CD-ROM drive. If the CD does not start
automatically, open the root directory of the CD in Windows Explorer and double-click
MPEGAx.exe.
2. Follow the on-screen instructions.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
90 en | Operation
VIP X1600 M4S
Establishing the Connection
At least the module in Slot 1 must be assigned a valid IP address and a compatible subnet
mask to operate the VIP X1600 XF on your network.
The following default address is preset at the factory: 192.168.0.1
1. Start the Web browser.
2. Enter the module's IP address as the URL. The connection is established and after a short
time you will see the LIVEPAGE with the video image.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Operation | en
91
6.2
The LIVEPAGE
live video image on the right of the browser window. Depending on the configuration, various
text overlays may be visible on the live video image (see Section 5.13 Advanced Mode: Display
Stamping, page 37).
depends on the settings on the LIVEPAGE Functions page (see Section 5.15 Advanced Mode:
LIVEPAGE Functions, page 40).
Maximum Number of Connections
If you do not connect, the unit may have reached its maximum number of connections.
Depending on the unit and network configuration, each module can have up to 25 Web
browser connections or up to 50 connections via VIDOS or Bosch Video Management System.
Protected Module
If the module is password protected against unauthorized access, the Web browser displays a
message to that effect and prompts you to enter the password when you call up access-
protected areas.
NOTICE!
The module offers the option to limit the extent of access using various authorization levels
(see Section 5.11 Advanced Mode: Password, page 35).
1. Enter the user name and associated password in the corresponding text fields.
2. Click OK. If the password is entered correctly, the Web browser displays the page that
was called up.
Protected Network
If a RADIUS server is employed in the network for managing access rights (802.1x
authentication), the module must be configured accordingly, otherwise no communication is
possible.
To configure the unit, you must connect the VIP X1600 XF directly to a computer using a
network cable. This is because communication via the network is not enabled until the
Identity and Password parameters have been set and successfully authenticated (see
Section 5.38 Advanced Mode: Advanced, page 77).
CAUTION!
The switch used for the network must support the multi-host operation when using 802.1x
authentication and must be configured so that a VIP X1600 XF with several modules can try
several hosts for communicating over the network.
!
Switching between the Modules
If multiple modules have been installed in a VIP X1600 XF, you can easily switch between the
modules in the same unit.
X
In the upper section of the window, click one of the links Module 1 to Module 4 to
switch to the corresponding module in the same VIP X1600 XF.
NOTICE!
A module that is installed in another base must be selected via its IP address.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
92 en | Operation
VIP X1600 M4S
Image Selection
You can view the image from each camera separately on a full screen. Alternatively, you can
display the camera images from all four video inputs together (Quad View).
1. Click one of the tabs above the video image to view one or all of the camera images.
2. Click one of the tabs Stream 1, Stream 2 or
M-JPEG below the video image to toggle between the different displays of the camera
images. The selection applies to all camera images.
View Control
The options for controlling peripheral devices (for example a pan/tilt camera head or a dome
camera) are dependent on the unit type installed and on the configuration of the module.
If a controllable unit is configured and connected to the module, the controls for the
peripheral are displayed to the left of the video image.
1. To control a peripheral, click the appropriate controls.
2. Move the mouse cursor over the video image. Additional options for controlling
peripherals are displayed with the mouse cursor.
Digital I/O
The alarm icons Input 1 to Input 4 are for information purposes and indicate the status of an
configuration determines whether the alarm is displayed, as well as additional details (see
Section 5.15 Advanced Mode: LIVEPAGE Functions, page 40).
Triggering Relay
You can switch connected units using the relays in the module (for example lights or door
openers).
X
To activate this, click the icon for the corresponding relay next to the video image. The
icon will be red when the relay is activated.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Operation | en
93
System Log / Event Log
connection. You can save these messages automatically in a file (see Section 5.15 Advanced
Mode: LIVEPAGE Functions, page 40).
these messages automatically in a file (see Section 5.15 Advanced Mode: LIVEPAGE Functions,
page 40).
1. If you want to delete the entries, click the delete icon in the top right-hand corner of the
relevant field.
2. If you want to view a detailed log, click the icon in the top right-hand corner of the
relevant field. A new window will open.
Audio Function (Audio Version Only)
Depending on the configuration, the module can send and receive audio signals. All users who
are connected by browsers receive the audio signals sent by the module.
NOTICE!
It is not possible to send audio signals to the module.
6.3
Saving Snapshots
JPEG format on your computer's hard drive. The icon for recording single images is only
visible if the unit is configured to enable this process (see Section Allow snapshots, page 41).
You can save snapshots from each of the four cameras in the Quad View. The icons below the
camera images apply to the four camera images in the following sequence: top left, top right,
bottom left, bottom right.
Click the icon. The image is saved at a resolution of 704 × 576 pixels (4CIF). The storage
location depends on the configuration of the module (see Section Path for JPEG and
MPEG files, page 41).
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
94 en | Operation
VIP X1600 M4S
6.4
Recording Video Sequences
computer's hard drive. The icon for recording video sequences is only visible if the unit is
configured to enable this process (see Section Allow local recording, page 41).
You can save video sequences from each of the four cameras in the Quad View. The icons
below the camera images apply to the four camera images in the following sequence: top left,
1. Click the icon to start recording. The storage location depends on the configuration of
the module (see Section Path for JPEG and MPEG files, page 41). A red dot in the icon
indicates that recording is in progress.
2. Click the icon again to stop recording.
NOTICE!
You can play back saved video sequences using the Player from Bosch Security Systems,
which can be installed from the product CD supplied with the VIP X1600 XF base.
Sequences are saved at the resolution that has been preset in the configuration for the
encoder (see Section 5.19 Advanced Mode: Encoder Profile, page 44).
6.5
Running Recording Program
The hard drive icon below the camera images on the LIVEPAGE changes during an automatic
recording.
A moving graphic will appear to indicate a running recording. If no recording is taking place, a
static icon is displayed.
NOTICE!
You can ascertain from the Quad View for which camera a recording is running by moving the
mouse cursor over the icon. A message is displayed below the mouse pointer.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Operation | en
95
6.6
The RECORDINGS Page
The RECORDINGS page for playing back recorded video sequences can be accessed from the
The RECORDINGS link is only visible if a storage medium has been selected (see
Section 5.21 Advanced Mode: Storage Management, page 48).
X
Click the RECORDINGS link in the navigation bar in the upper section of the window. The
playback page appears.
Camera
Here you can select the camera from which you want to view the recordings. Playback of the
recordings starts immediately in the video window.
Recording
Here you can select the recording that you want to view. Playback of the recording starts
immediately in the video window.
Controlling a Playback
You will see a time bar below the video image for quick orientation. A green arrow above the
bar indicates the position of the image currently being played back within the sequence.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
96 en | Operation
VIP X1600 M4S
The time bar offers various options for navigation.
Red bars indicate the points in time where alarms were triggered. Drag the green arrow to
navigate to these points quickly.
1. You can change the time interval by clicking the zoom keys (magnifying glass icons). The
display can span a range from two months to a few seconds.
2. Drag the green arrow to the point in time at which playback should begin. The date and
time display below the bar provides orientation to the second.
Buttons
You can control playback by means of the buttons below the video image. The buttons have
the following functions:
Start or pause playback
Jump to the start of the active video sequence or to the previous sequence
Jump to the start of the next video sequence
Slide Control
You can use the slide control to control playback speed.
Bookmarks
In addition, you can set markers in the sequences, so-called bookmarks, and jump directly to
these. These bookmarks are indicated as small yellow arrows above the time interval. Use the
bookmarks as follows:
Jump to the previous bookmark
Set bookmark
Jump to the following bookmark
X
Right-click a bookmark to delete it.
NOTICE!
Bookmarks are only valid while you are in the RECORDINGS page; they are not saved with the
sequences. As soon as you leave the page all bookmarks are deleted.
Trick Mode
If you are using a mouse with a scroll wheel, you can view recordings frame by frame in trick
mode. To do this, place the mouse cursor in the timeline below the timescale and turn the
scroll wheel. Playback is automatically stopped (paused) during scrolling. Trick mode requires
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Operation | en
97
significantly higher memory capacity and computing power. For this reason, the number of
cameras used in this mode can be restricted in the Configuration Manager program.
6.7
Installing the Player
You can play back saved video sequences using the Player from Bosch Security Systems,
which can be found on the product CD supplied with the VIP X1600 XF base.
NOTICE!
In order to play back saved sequences using the Player, suitable MPEG ActiveX software must
be installed on the computer.
1. Insert the CD into the computer's CD-ROM drive. If the CD does not start automatically,
open the CD in Windows Explorer and double-click the index.html file to start the menu.
2. From the list field at the top, select the language you require and click Tools in the menu.
3. Click the Archive Player option. The installation will start. Follow the instructions in the
installation program. The Archive Player will be installed at the same time as the Player.
4. After successful installation, you will find two new icons on your desktop for the Player
and the Archive Player.
5. Start the Player by double-clicking the Player icon.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
98 en | Operation
VIP X1600 M4S
6.8
Hardware Connections Between Video Servers
You can easily connect a VIP X1600 M4S encoder module with cameras connected to it, acting
as a sender, to a compatible hardware decoder (such as the VIP XD) with a connected
monitor, acting as a receiver, via an Ethernet network. In this way it is possible to cover long
distances without the need for major installation or cabling work.
NOTICE!
The sender and receiver must be located in the same subnet to establish a hardware
connection.
Installation
Compatible video servers are designed to connect to one another automatically, provided
they are correctly configured. They only need to be part of a closed network. Proceed as
follows to install the units:
1. Connect the units to the closed network using Ethernet cables.
2. Connect them to the power supply.
NOTICE!
Make sure that the units are configured for the network environment and that the correct IP
Connections configuration page (see Section 5.26 Advanced Mode: Alarm Connections,
page 56).
Connecting
There are three options for establishing a connection between a sender and a compatible
receiver in a closed network:
–
–
–
an alarm,
a terminal program, or
Internet Explorer.
NOTICE!
Connecting with a Web browser is described in the manual of the relevant unit that is to be
used as the receiver, for example VIP XD.
Connecting on Alarm
With the appropriate configuration, a connection between a sender and a receiver is made
automatically when an alarm is triggered (see Section 5.26 Advanced Mode: Alarm Connections,
page 56). After a short time the live video image from the sender appears on the connected
monitor.
This option can also be used to connect a sender and a compatible receiver using a switch
connected to the alarm input. You do not need a computer to make the connection in this
case.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Operation | en
99
Various requirements must be met in order to operate with a terminal program (see
Section 8.9 Communication with Terminal Program, page 109).
1. Start the terminal program and enter the command 1 in the main menu to switch to the
IP menu.
2. Enter the command 4 in the IP menu to change the remote IP address, then enter the IP
address of the unit you wish to connect to.
3. Enter the command 0 to return to the main menu and then enter the command 4 to
switch to the Rcp+ menu.
4. In the Rcp+ menu, enter the command 5 to activate the automatic connection.
Closing the Connection with a Terminal Program
1. Start the terminal program and enter the command 4 in the main menu to switch to the
Rcp+ menu.
2. In the Rcp+ menu, enter the command 5 to deactivate the automatic connection.
6.9
Operation Using Software Decoders
The VIP X1600 XF video server combines with VIDOS to provide a high-performance system
solution.
VIDOS is a software package for operating, controlling and managing CCTV installations (such
as surveillance systems) at remote locations. It runs under Microsoft Windows operating
systems. It is primarily designed for decoding video, audio and control data received from a
remote sender.
Many options are provided for operation and configuration when using a VIP X1600 XF with
VIDOS. Please refer to the software documentation for more details.
Another program that supports the VIP X1600 XF is Bosch Video Management System.
Bosch Video Management System is an IP video security solution that enables the seamless
management of digital video, audio and data over any IP network. It was developed for use
with Bosch CCTV products as one component of an extensive video security management
system. It allows you to integrate your existing components into a simple-to-control system or
into the entire Bosch range, benefiting from a complete security solution based on the latest
technology and years of experience.
The VIP X1600 XF video server is also designed for use with the DiBos 8 digital recorder.
DiBos 8 records up to 32 video and audio streams and is available as IP software or hybrid
DVR with additional analog camera and audio inputs. DiBos supports the most diverse
functions on the VIP X1600 XF, for example relay activation, remote control of peripherals and
remote configuration. DiBos 8 can use the alarm inputs for event triggering and, on release of
the MOTION+ motion detector, record the activated cells to enable intelligent motion search.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
100 en | Operation
VIP X1600 M4S
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Maintenance and Upgrades | en 101
7
Maintenance and Upgrades
7.1
Testing the Network Connection
You can use the ping command to check the connection between two IP addresses. This
allows you to test whether a unit in the network is active.
1. Open the DOS command prompt.
2. Type ping followed by the IP address of the unit.
If the unit is found, the response appears as Reply from ... followed by the number of bytes
sent and the transmission time in milliseconds. If not, the unit cannot be accessed over the
network. This might be because:
–
The VIP X1600 XF is not correctly connected to the network. Check the cable
connections in this case.
–
The module is not correctly integrated into the network. Check the IP address, subnet
mask and gateway address.
7.2
Unit Reset
You can use the Factory Reset button to restore a module to its original settings. Any changes
to the settings are overwritten by the factory defaults. A reset may be necessary, for example,
if the unit has invalid settings that prevent it from functioning as desired.
CAUTION!
All configured settings will be discarded during a reset.
If necessary, back up the current configuration using the Download button on the
Maintenance configuration page (see Section 5.43 Advanced Mode: Maintenance, page 84).
!
NOTICE!
After a reset, the module can only be addressed via the factory default IP address. The IP
address can be changed as described in the Installation chapter (see Section 4.4 Setup Using
the Configuration Manager, page 21).
Maintenance configuration page (see Section 5.43 Advanced Mode: Maintenance,
page 84).
2. Using a pointed object, press the Factory Reset button located below the orange terminal
block until the module's LED on the front panel of the VIP X1600 XF flashes red. All
module settings will revert to their defaults.
3. Change the IP address of the module if necessary.
4. Configure the module to meet your requirements.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
102 en | Maintenance and Upgrades
VIP X1600 M4S
7.3
Repairs
CAUTION!
Do not change any components in the module or the VIP X1600 XF base. The unit does not
contain any user-serviceable parts.
!
Ensure that all maintenance or repair work is carried out only by qualified personnel
(electrical engineers or network technology specialists). In case of doubt, contact your
dealer's technical service center.
7.4
Transfer and Disposal
A VIP X1600 XF, the VIP X1600 XF base or a module should only be passed on together with
this Installation and Operating Manual.
Your Bosch product is designed and manufactured with high-quality materials and
components which can be recycled and reused.
This symbol means that electrical and electronic equipment, at their end-of-life, should be
disposed of separately from your household waste.
In the European Union, there are separate collection systems for used electrical and
electronic products. Please dispose of this equipment at your local community waste
collection/recycling center.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Appendix | en 103
8
Appendix
8.1
Troubleshooting
If you are unable to resolve a malfunction, please contact your supplier or system integrator,
You can view a range of information about your unit version on the System Overview page
(see Section 5.46 Advanced Mode: System Overview, page 87). Make a note of this information
before contacting Customer Service. You can download an internal maintenance log from the
unit on the Maintenance page if you wish to send it to Customer Service by e-mail (see
Section Maintenance log, page 85).
The following table is intended to help you identify the causes of malfunctions and correct
them where possible.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
104 en | Appendix
VIP X1600 M4S
8.2
General Malfunctions
Malfunction
Possible causes
Recommended solution
No connection between Incorrect cable connections.
Check all cables, plugs,
contacts, terminals and
connections.
module and terminal
program.
The computer's serial interface Check the other serial interface.
is not connected.
Interface parameters do not
match.
If necessary select a different
interface and make sure that the
computer's interface parameters
match those of the module. Try
the following standard
parameters: 19,200 baud, 8 data
bits, no parity, 1 stop bit. Next,
disconnect the unit from the
power supply and reconnect it
again after a few seconds.
No image on the monitor. Monitor error.
Connect local camera or other
video source to the monitor and
check the monitor function.
Faulty cable connections.
The module's configuration.
Faulty installation.
Check all cables, plugs, contacts
and connections.
No connection
Check all configuration
parameters.
established, no image
transmission.
Check all cables, plugs, contacts
and connections.
Wrong IP address.
Check the IP addresses
(terminal program).
Faulty data transmission within Check the data transmission
the LAN.
with ping.
The maximum number of
Wait until there is a free
connections has been reached. connection and then call the
sender again.
No audio transmission to Hardware fault.
remote station.
Check that all connected audio
units are operating correctly.
Faulty cable connections.
Check all cables, plugs, contacts
and connections.
Incorrect configuration.
Check the audio parameters on
the Audio configuration page.
The audio voice connection is
already in use by another
receiver.
Wait until the connection is free
and then call the sender again.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Appendix | en 105
Malfunction
Possible causes
Recommended solution
The module does not
report an alarm.
Alarm source is not selected.
Select possible alarm sources on
the Alarm Inputs configuration
page.
No alarm response specified.
Specify the desired alarm
response on the Alarm
Connections configuration page,
change the IP address if
necessary.
Control of cameras or
other units is not
possible.
The cable connection between Check all cable connections and
the serial interface and the
ensure all plugs are properly
fitted.
connected unit is not correct.
The interface parameters do not Make sure that the settings of all
match those of the other unit
connected.
units involved are compatible.
The module is not
operational after a
firmware upload.
Power failure during
Have the module checked by
Customer Service and replace if
necessary.
programming by firmware file.
Incorrect firmware file.
Enter the IP address of the
module followed by /main.htm
in your Web browser and repeat
the upload.
Placeholders with a red
cross are displayed
instead of the ActiveX
components.
Sun JVM is not installed on the Install Sun JVM from the
computer or is not enabled. product CD.
Web browser contains
empty fields.
Active proxy server in network. Create a rule in the local
computer's proxy settings to
exclude local IP addresses.
Bosch Security Systems
Installation and Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
DOC | V4.0 | 2009.06
106 en | Appendix
VIP X1600 M4S
8.3
Malfunctions with iSCSI Connections
Malfunction
Possible causes
Recommended solution
After connecting to the
iSCSI destination, no
LUNs are displayed.
Incorrect LUN mapping during
iSCSI system configuration.
Check the iSCSI system
configuration and reconnect.
After connecting to the
iSCSI destination, "LUN
FAIL" appears below a
node.
The LUN list could not be read, Check the iSCSI system
as it was assigned to the wrong configuration and reconnect.
network interface.
LUN mapping is not
possible.
Some iSCSI systems do not
support the use of an initiator
extension.
Delete the initiator extension on
the Identification configuration
page.
8.4
LEDs
The VIP X1600 XF network video server is equipped with a number of LEDs that show the
operating status and can give indications of possible malfunctions.
RJ45 Sockets 10/100/1000 Base-T
Green LED lights up:
10 MB network connection established.
Green LED flashes:
Data transmission via 10 MB network connection.
100 MB network connection established.
Data transmission via 100 MB network connection.
1 GB network connection established.
Green and orange LEDs light up:
Green and orange LEDs flash:
Orange LED lights up:
Orange LED flashes:
Data transmission via 1 GB network connection.
SFP
Does not light up:
Lights up yellow:
Flashes yellow:
No connection.
Connection established.
Data being transmitted.
Module 1 / Module 2 / Module 3 / Module 4
Does not light up:
Lights up green:
Flashes green:
Flashes red:
Slot not occupied.
Module is switched on.
The module is being accessed.
Startup in progress.
Lights up red:
Module is faulty, for example following failed firmware
upload.
Power/Fail
Does not light up:
Lights up green:
Flashes red:
VIP X1600 XF is switched off.
Startup complete, VIP X1600 XF is operational.
Defect in fans or redundant power supply unit.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Bosch Security Systems
VIP X1600 M4S
Appendix | en 107
8.5
Processor Load
If the VIP X1600 M4S encoder module is accessed via the Web browser, you will see both of
the processor load indicators in the top left of the window next to the manufacturer's logo.
Moving the mouse cursor over the graphic indicator displays the status of the processor
together with the numerical values. This information may help you with troubleshooting or
fine tuning the unit.
8.6
Network Connection
You can display information about the network connection. To do this, move the cursor over
the i icon.
Link
UL
Ethernet link type
Uplink, speed of the outgoing data traffic
Downlink, speed of the incoming data traffic
DL
8.7
8.8
Serial interface
Options for using the serial interface include transferring transparent data, controlling
connected units or operating the unit with a terminal program.
The serial interface supports the RS-232/RS-422/RS-485 transmission standards. The mode
used depends on the current configuration (see Section 5.36 Advanced Mode: COM1, page 72).
Connection is via the terminal block.
Terminal Block
The terminal block has several contacts for:
–
–
–
4 alarm inputs
4 relay outputs
Serial data transmission
The pin assignment of the serial interface depends on the interface mode used (see
Section 5.36 Advanced Mode: COM1, page 72).
Contact
CTS
RS232 mode
RS422 mode
RS485 mode
CTS (clear to send)
TxD (transmit data)
RxD (receive data)
RTS (ready to send)
GND (ground)
RxD- (receive data minus)
TxD- (transmit data minus)
RxD+ (receive data plus)
TxD+ (transmit data plus)
—
Data-
TXD
RXD
Data+
—
RTS
GND
Bosch Security Systems
Installation and Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
DOC | V4.0 | 2009.06
108 en | Appendix
VIP X1600 M4S
Contact
IN1
IN2
IN3
IN4
GND
R1
Function
Alarm input 1
Alarm input 2
Alarm input 3
Alarm input 4
Ground
Relay output 1
Relay output 2
Relay output 3
Relay output 4
R2
R3
R4
Connect the alarm input IN to the ground contact GND when connecting alarm signals.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Appendix | en 109
8.9
Communication with Terminal Program
Data Terminal
If a module cannot be found in the network or the connection to the network is interrupted,
you can connect a data terminal to the VIP X1600 XF for initial setup and setting of important
parameters. The data terminal consists of a computer with a terminal program.
You require a serial transmission cable with a 9-pin Sub-D plug to connect to the computer
and open ends for connection to the terminal block of the module (see Section 8.8 Terminal
Block, page 107).
HyperTerminal, a communications accessory included with Microsoft Windows, can be used
as the terminal program.
NOTICE!
Information on installing and using HyperTerminal can be found in the manuals or in the online
help for MS Windows.
1. Disconnect the VIP X1600 XF from the Ethernet network before working with the
terminal program.
2. Connect the serial interface of the module using any available serial interface on the
computer.
Configuring the Terminal
Before the terminal program can communicate with the module, the transmission parameters
must be matched. Make the following settings for the terminal program:
–
–
–
–
–
19,200 bps
8 data bits
No parity check
1 stop bit
No protocol
Command Inputs
After the connection has been established, you must log onto the module to access the main
menu. Other submenus and functions can be accessed using the on-screen commands.
1. If necessary, turn off the local echo so that entered values are not repeated on the
display.
2. Enter one command at a time.
3. When you have entered a value (such as an IP address), check the characters you have
entered before pressing Enter to transfer the values to the module.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
110 en | Appendix
VIP X1600 M4S
Assigning an IP address
To use a module in your network, you must assign it an IP address that is valid for your
network.
The following default address is preset at the factory: 192.168.0.1
1. Start a terminal program such as HyperTerminal.
2. Enter the user name service. The terminal program displays the main menu.
3. Enter command 1 to open the IP menu.
4. Enter 1 again. The terminal program displays the current IP address and prompts you to
enter a new IP address.
5. Enter the desired IP address and press Enter. The terminal program displays the new IP
address.
6. Use the displayed commands for any additional settings you require.
NOTICE!
You must reboot to activate the new IP address, a new subnet mask or a gateway IP address.
Reboot
Briefly interrupt the power supply to the VIP X1600 XF for a reboot (disconnect the power
supply unit from the mains supply and switch on again after a few seconds).
Additional Parameters
You can use the terminal program to check other basic parameters and modify them where
necessary. Use the on-screen commands in the various submenus to do this.
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Appendix | en 111
8.10
Copyrights
The firmware 4.0 uses the fonts "Adobe-Helvetica-Bold-R-Normal--24-240-75-75-P-138-
ISO10646-1" and "Adobe-Helvetica-Bold-R-Normal--12-120-75-75-P-70-ISO10646-1" under the
following copyright:
Copyright 1984-1989, 1994 Adobe Systems Incorporated.
Copyright 1988, 1994 Digital Equipment Corporation.
Permission to use, copy, modify, distribute and sell this software and its documentation for
any purpose and without fee is hereby granted, provided that the above copyright notices
appear in all copies and that both those copyright notices and this permission notice appear
in supporting documentation, and that the names of Adobe Systems and Digital Equipment
Corporation not be used in advertising or publicity pertaining to distribution of the software
without specific, written prior permission.
This software is based in part on the work of the Independent JPEG Group.
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
112 en | Appendix
VIP X1600 M4S
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Specifications | en 113
9
Specifications
9.1
VIP X1600 M4S Encoder Module
Operating voltage
Power consumption
Data interfaces
Alarm inputs
Supply via VIP X1600 XF base housing
Max. 12 W
1 × RS-232/RS-422/RS-485, bidirectional, push-in terminal
4 × push-in terminals (non-isolated closing contact),
maximum activation resistance 10 Ohm
Relay outputs
Video inputs
Audio inputs
4 × push-in terminal, 30 V , 2 A (SELV), 8 contacts
p-p
4 × BNC socket 0.7 to 1.2 V , 75 Ohm, PAL/NTSC
p-p
Audio versions only:
2 × 3.5 mm stereo socket, mono
5.5 V
max., impedance 9 kOhm typ.
p-p
Thermal value
41 BTU/h
Operating conditions
Temperature: 0 to +50 °C / +32 to +122 °F,
relative humidity: 20 to 80%, non-condensing
Approvals
IEC 60950; UL 1950; AS/NZS 3548; EN 50121-4, EN 55103-
1, -2; EN 55130-4; EN 55022; EN 55024; EN 61000-3-2;
EN 61000-3-3; FCC 47 CFR Chapter 1 Part 15
Weight
approx. 120 g / 0.27 lb
9.2
Protocols/Standards
Video standards
PAL, NTSC
Video coding protocols
Video data rate
MPEG-4, H.264 Baseline Profile, M-JPEG
9.6 kbps to 6 Mbps per channel
Image resolutions (PAL/NTSC)
704 × 576/480 pixels (4CIF/D1)
704 × 288/240 pixels (2CIF)
464 × 576/480 pixels (2/3 D1)
352 × 576/480 pixels (1/2 D1)
352 × 288/240 pixels (CIF)
176 × 144/120 pixels (QCIF)
Total delay
120 ms (PAL/NTSC, MPEG-4, no network delay)
25/30 ips max.
Image refresh rate
Network protocols
RTP, Telnet, UDP, TCP, IP, HTTP, HTTPS, DHCP, IGMP V2,
IGMP V3, ICMP, ARP, SNMP (V1/V2c/V3 MIB-II), 802.1x
Audio coding protocol
Audio sampling rate
Audio data rate
G.711, 300 Hz to 3.4 kHz
8 kHz
80 kbps
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
114 en | Specifications
VIP X1600 M4S
9.3
Image Refresh Rate
MPEG-4
4 cameras
2 cameras
25/30 ips
25/30 ips
25/30 ips
1 camera
25/30 ips
25/30 ips
25/30 ips
4CIF
12.5/15 ips
25/30 ips
25/30 ips
2/3 D1
2CIF
H.264
4 cameras
2 cameras
1 camera
2CIF
12.5/15 ips
25/30 ips
25/30 ips
DOC | V4.0 | 2009.06
Installation and Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Bosch Security Systems
VIP X1600 M4S
Glossary | en 115
10
Glossary
Symbols
10/100/1000 Base-T IEEE-802.3 specification for 10, 100 or 1000 Mbps Ethernet
802.1x
The IEEE 802.1x standard provides a general method for authentication and authorization in
IEEE-802 networks. Authentication is carried out via the authenticator, which checks the
transmitted authentication information using an authentication server (see RADIUS server)
and approves or denies access to the offered services (LAN, VLAN or WLAN) accordingly.
A
ARP
Address Resolution Protocol: a protocol for mapping MAC and IP addresses
B
Baud
bps
Unit of measurement for the speed of data transmission
Bits per second, the actual data rate
Bosch Video over IP unit
BVIP
C
CABAC
Context-based Adaptive Binary Arithmetic Coding; an effective way to compress binary data
without loss. In the video standard MPEG-4/Part10 (H.264/AVC), CABAC is characterized by
high picture quality, a high compression rate and high computing requirements.
CF
CompactFlash; interface standard, for digital storage media amongst other things. Used in
computers in the form of CF cards, digital cameras and Personal Digital Assistants (PDA).
CIF
Common Intermediate Format, video format with 352 × 288/240 pixels
D
DHCP
Dynamic Host Configuration Protocol: uses an appropriate server to enable dynamic
assignment of an IP address and other configuration parameters to computers on a network
(Internet or LAN)
DNS
Domain Name System, mainly used for converting domain names to IP addresses
DynDNS
DNS hosting service that works according to RFC 2845 and stores the IP addresses of its
clients in a database, ready for use
F
FTP
File Transfer Protocol
Full duplex
Simultaneous data transmission in both directions (sending and receiving)
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
116 en | Glossary
VIP X1600 M4S
G
GBIC
GOP
GigaBit Interface Converter; applied in network technology to render interfaces flexible, for
converting an electrical interface into an optical interface, for example. This enables flexible
operation of an interface as a Gigabit Ethernet via twisted-pair cables or fiber optic cables.
Group of Pictures
H
HTTP
Hypertext Transfer Protocol: protocol for transmitting data over a network
HTTPS
Hypertext Transfer Protocol Secure: encrypts and authenticates communication between Web
server and browser
I
ICMP
Internet Control Message Protocol
ID
Identification: a machine readable character string
Institute of Electrical and Electronics Engineers
Internet Group Management Protocol
IEEE
IGMP
Internet Protocol
The main protocol used on the Internet, normally in conjunction with the Transfer Control
Protocol (TCP): TCP/IP
IP
See Internet Protocol
IP address
A 4-byte number uniquely defining each unit on the Internet. It is usually written in dotted
decimal notation, for example "209.130.2.193"
iSCSI
ISDN
Storage over IP process for storage networks; specifies how storage protocols are operated
over IP
Integrated Services Digital Network
J
JPEG
kbps
LAN
An encoding process for still images (Joint Photographic Experts Group)
K
Kilobits per second, the actual data rate
L
See Local Area Network
Local Area Network A communications network serving users within a limited geographical area such as a building
or university campus. It is controlled by a network operating system and uses a transfer
protocol.
LUN
Logical Unit Number; logical drive in iSCSI storage systems
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Glossary | en 117
M
MAC
MIB
Media Access Control
Management Information Base; a collection of information for remote servicing using the
SNMP protocol
MPEG-2
MPEG-4
MSS
Improved video/audio compression standard, compression on highest level allows images in
studio quality; now established as broadcast standard
A further development of MPEG-2 designed for transmitting audiovisual data at very low
transfer rates (for example over the Internet)
Maximum Segment Size; maximum byte figure for the user data in a data packet
N
Net mask
NTP
A mask that explains which part of an IP address is the network address and which part is the
host address. It is usually written in dotted decimal notation, for example "255.255.255.192."
Network Time Protocol; a standard for synchronizing computer system clocks via packet-
based communication networks. NTP uses the connectionless network protocol UDP. This
was developed specifically for enabling time to be reliably transmitted over networks with
variable packet runtime (Ping).
O
OF
Optical Fiber; now used predominantly as the transmission medium for line-borne
telecommunication processes (glass fiber cable)
P
Parameters
QCIF
Values used for configuration
Q
Quarter CIF, video format with 176 × 144/120 pixels
R
RADIUS server
Remote Authentication Dial-In User Service: a client/server protocol for the authentication,
authorization and accounting of users with dial-up connections on a computer network.
RADIUS is the de-facto standard for central authentication of dial-up connections via Modem,
ISDN, VPN, Wireless LAN (see 802.1x) and DSL.
RFC 868
RS-232/-422/-485
RTP
A protocol for synchronizing computer clocks over the Internet
Standards for serial data transmission
Real-Time Transport Protocol; a transmission protocol for real-time video and audio
RTSP
Real-Time Streaming Protocol; network protocol for controlling the continuous transmission
of audiovisual data (streams) or software over IP-based networks
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
Download from Www.Somanuals.com. All Manuals Search And Download.
118 en | Glossary
VIP X1600 M4S
S
SFP
Small Form-factor Pluggable; small, standardized module for network connections, designed
as a plug connector for high-speed network connections
SNIA
SNMP
Storage Networking Industry Association; association of companies for defining the iSCSI
standard
Simple Network Management Protocol; a protocol for network management, for managing and
monitoring network components
SNTP
Simple Network Time Protocol; a simplified version of NTP (see NTP)
Secure Sockets Layer; an encryption protocol for data transmission in IP-based networks
See Net mask
SSL
Subnet mask
T
TCP
Transmission Control Protocol
Telnet
TLS
Login protocol with which users can access a remote computer (Host) on the Internet
Transport Layer Security; TLS 1.0 and 1.1 are the standard advanced developments of SSL 3.0
(see SSL)
TTL
Time-To-Live; life cycle of a data packet in station transfers
U
UDP
URL
UTP
User Datagram Protocol
Uniform Resource Locator
Unshielded Twisted Pair
W
WAN
See Wide Area Network
Wide Area Network A long distance link used to extend or connect remotely located local area networks
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
VIP X1600 M4S
Index | en 119
11
Index
A
E
Activation key 86
Alarm e-mail 68
Echo 109
E-mail 68
Alarm input 20
Alarm inputs 71
EPROM 84
Alarm message 38
Alarm script 66
Alarm sensors 51
Audio connection 15
Auto-connect 58
F
False alarms 61
Formatting 49
B
Basic mode 25
Baud rate 73
Bookmarks 96
G
Gateway 30, 75
H
C
HTTP port 75
HTTPS port 75
Camera 73
Camera selection 92
Cameras 19
I
IEEE 802.1x 78
Changes 26
COM1 73
Configuration download 85
Connect on alarm 56
Contrast 43
IGMP 81
Image quality 82
Installation conditions 17
Interface 107
Internal clock 36
iSCSI settings 49
Control 73
Control functions 92
Controlling a playback 95
J
JPEG image size 82
JPEG posting 82
D
Date 36
Daylight saving time 36
Device ID 33
DHCP server 29
Dome camera 20
Dual Streaming 12, 44
DynDNS 76
L
Language 39
Licenses 86
Livepage 40
Low Voltage Directive 8
Low-pass filter 43
M
Maintenance 9
Manufacturer logo 38
Media-replay 95
Milliseconds 38
Motion detector 59
Motion detector defaults 59, 60
Bosch Security Systems
Installation and Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
DOC | V4.0 | 2009.06
120 en | Index
MTU value 75, 76
SMS 69
SNMP 77
Source type 42
Multicasting 81
Multi-unicast 81
N
Navigation 26
Network 29, 74, 77
Network connection 107
O
Stop bits 73
P
Parity check 73
Peripheral device control 92
Player 97
Summer time 36
Symbols 7
Synchronize 28, 36
System log 41, 93
Port 75, 82
Post-alarm time 51
Pre-alarm time 51
Processor load 107
Profile configuration 45
T
Target data rate 45
Test 88
Time 29, 36, 38
Time zone 36
Protocol 73
R
RADIUS 78
Reboot 22, 110
Receiver 12
Receiver password 56
Recording media 48
Recording scheduler 53
Regulations 7
TLS 75
Transmission parameters 109
Traps 78
Trigger relay 72
TTL 82
Relay 15, 21
U
Unicast 81
Reset 101
Router 82
S
Unit date 36
Unit time 29, 36
URL 24, 90
Saturation 43
Saving event log 41
Saving system log 41
DOC | V4.0 | 2009.06
Installation and Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Bosch Security Systems
VIP X1600 M4S
Index | en 121
V
Value 43
VCR 42
Video sensor 59
VRM 48
W
Watermarking 38
Bosch Security Systems
Installation and Operating Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
DOC | V4.0 | 2009.06
122 en | Index
VIP X1600 M4S
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Bosch Security Systems
Robert-Koch-Straße 100
85521 Ottobrunn
Germany
Telefon
Fax
089 6290-0
089 6290-1020
www.boschsecurity.com
© Bosch Security Systems, 2009
Download from Www.Somanuals.com. All Manuals Search And Download.
|