Bosch Appliances DVD Player Divar Digital Versatile Recorder User Manual |
Divar - Digital Versatile Recorder
EN Installation Instructions
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual
EN | i
Divar
Digital Versatile Recorder
Installation manual
Chapters
1.
2.
3.
4.
5.
6
Introduction
Quick install
Operating instructions
Hardware setup
Menu system
Using the Configuration Tool
Menu default values
Technical specifications
7
8.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual
EN | ii
Alarm input recording . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Enable motion for . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Motion recording . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Approximate recording duration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
Network settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
DHCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
DVR name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
IP address, Subnet mask and Default gateway . . . . . . . . . . . . . . . . . . . 2-6
MAC address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
Bandwidth limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Digital video recorder for security applications . . . . . . . . . . . . . . . . . . . . . . 1-1
Versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
On-screen help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Package contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Installation environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Associated equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
DVD writer** . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Operating instructions . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Front panel controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Primary functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Alternate functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Viewing pictures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
Viewing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
Live, playback and search modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
Live mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
Playback mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
Search mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9
Search criteria . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9
Search results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10
Triggers and alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11
Alarm inputs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12
Motion alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12
Video loss alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13
Multiple alarms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13
Disk-full alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13
Quick install . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Primary connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Optional connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Powering up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
First-time use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Quick install menu >. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Time Zone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Time format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Date format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Date . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Active cams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Alarm Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Recording settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Network settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Save & exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Cancel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Recording settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Day period . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Weekend . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Rec day . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Rec weekend/night . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Enable alarm inputs for . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Hardware setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Rack mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
Camera connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
Monitor connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual
EN | iii
Console port connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
Keyboard connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
Ethernet connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
Control port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
External I/O connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7
SCSI connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
Playback Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-10
Event Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-10
History Log Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-11
Local Passwords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-12
Connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-12
Licenses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-13
Input and output contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-13
Profiles > . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-13
Calendar setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-13
Profile override . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-14
Profile manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-14
System behavior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-14
Menu system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
Overview of the menu system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
Accessing the menu from the unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
Main Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3
History > . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4
History Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4
History List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4
Disk manager >. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4
Status Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4
Local archiving . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5
Protected Recordings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5
Authenticity Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6
Stop recording . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6
Storage setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6
Delete Video . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6
Erase Disk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6
Time/Date > . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-7
Synchronize . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-7
View Settings >. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-7
Camera setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-7
Camera controllable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-8
Bilinx cameras . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-8
Sequences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-8
Configure Monitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-8
System Settings > . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-9
Recording Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-9
Using the Configuration Tool . . . . . . . . . . . . . . . . . . 6-1
Getting started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
System requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
Installing the Configuration Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
Starting the Configuration Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
How to Log in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3
Menu structure differences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4
Introducing the main window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5
Overview button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5
History button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5
Settings button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5
Service button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6
Help button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6
Logout button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6
Using the control buttons. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6
Menu default values . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1
Technical specifications . . . . . . . . . . . . . . . . . . . . . . 8-1
Electrical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2
Mechanical. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3
Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3
Accessories (Optional). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual
EN | iv
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
SAFETY PRECAUTIONS
CAUTION
RISK OF ELECTRIC
SHOCK. DO NOT OPEN!
2. Keep these instructions.
CAUTION: TO REDUCE THE RISK OF ELECTRICAL
SHOCK, DO NOT OPEN COVERS. NO USER
SERVICEABLE PARTS INSIDE. REFER SERVICING TO
QUALIFIED SERVICE PERSONNEL.
3. Heed all warnings.
4. Follow all instructions.
This label may appear on the bottom of the unit due to space limitations.
The lightning flash with an arrowhead symbol within an
equilateral triangle is intended to alert the user to the
presence of uninsulated "dangerous voltage" within the
product's enclosure that may be of sufficient magnitude
to constitute a risk of electric shock to persons.
5. Do not use this apparatus near water.
6. Clean only with a dry cloth.
7. Do not block any ventilation openings. Install in accordance with the
manufacturer's instructions.
The exclamation point within an equilateral triangle
is intended to alert the user to presence of important
operating and maintenance (servicing) instructions in
the literature accompanying the appliance.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or
other apparatus (including amplifiers) that produce heat.
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO
NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE
AND OBJECTS WITH LIQUIDS, SUCH AS VASES, SHOULD
NOT BE PLACED ON THIS APPARATUS.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A
polarized plug has two blades with one wider that the other. A grounding-type
plug has two blades and a third grounding prong. The wide blade or third prong
are provided for your safety. If the provided plug does not fit into the outlet,
consult an electrician for replacement of the obsolete outlet.
Attention: Installation should be performed by
qualified service personnel only in accordance with the
National Electrical Code or applicable local codes.
10. Protect the power cord from being walked on or pinched particularly at
plugs, convenience receptacles, and the point where they exit from the
apparatus.
Power Disconnect. Units have power supplied
whenever the power cord is inserted into the power
source. The power cord is the main power disconnect
for all units.
The socket outlet shall be installed near the
equipment and shall be easily accessible.
11. Only use attachments/accessories specified by the manufacturer.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual
EN | v
12. Use only with the cart, stand, tripod, bracket, or table
specified by the manufacturer, or sold with the apparatus.
When a cart is used, use caution when moving the cart/
apparatus combination to avoid injury from tip-over.
20. Safety Check - Upon completion of any service or repairs to this unit, ask the
service technician to perform safety checks to determine that the unit is in
proper operating condition.
21. Coax Grounding - If an outside cable system is connected to the unit, be sure
the cable system is grounded. U.S.A. models only--Section 810 of the National
Electrical Code, ANSI/NFPA No.70-1981, provides information with respect to
proper grounding of the mount and supporting structure, grounding of the coax
to a discharge unit, size of grounding conductors, location of discharge unit,
connection to grounding electrodes, and requirements for the grounding
electrode.
13. Unplug this unit during lightning storms or when unused for long periods of
time.
14. Refer all servicing to qualified service personnel. Servicing is required when
the apparatus has been damaged in any way, such as power-supply cord or plug
is damaged, liquid has been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moistue, does not operate normally, or
has been dropped.
CAUTION
Use of controls or adjustments or performance of procedures other than
those specified herein may result in hazardous radiation exposure.
15. Moving - Disconnect the power before moving the unit. The unit should be
moved with care. Excessive force or shock may result in damage to the unit and
the hard disk drives.
16. Power Sources - This unit should be operated only from the type of power
source indicated on the marking label. If you are not sure of the type of power
supply you plan to use, consult your appliance dealer or local power company.
17. Overloading - Do not overload outlets and extension cords as this can result
in a risk of fire or electric shock.
18. Object and Liquid Entry - Never push objects of any kind into this unit
through openings, as they may touch dangerous voltage points or short out parts
that could result in a fire or electric shock. Never spill liquid of any kind on the
unit.
19. Replacement Parts - When replacement parts are required, be sure the
service technician has used replacement parts specified by the manufacturer or
have the same characteristics as the original part. Unauthorized substitutions
may result in fire, electric shock, or other hazards.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual
EN | vi
FCC & ICES INFORMATION
Reference
(U.S.A. and Canadian Models Only)
This is a Class B product. This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undisired operation.
Definition of terms
Cameo:
Single camera picture in a multiscreen display.
Dwell time: The length of time that an alarm indicator continues to operate
after the event causing it has occurred. The length of time a single
image of a sequence is shown.
Full-screen: A display that only shows one picture occupying a full screen.
Multiscreen: The division of a display screen so that it shows a certain number
of cameras at the same time.
The internal DVD writer is a laser product. The following classification label is
located on the drive.
Sequence:
Camera pictures shown one after the other in time either in full-
screen or quad modes.
Quad:
Four camera pictures shown on one display screen.
CLASS 1 LASER PRODUCT
CAUTION:
INVISIBLE LASER RADIATION WHEN OPEN.
AVOID EXPOSURE TO BEAM.
Icons shown on the screen
Alarm
Play forward
Pause
Motion
Network
Error
Play reverse
Fast forward
Fast reverse
Freeze
Zoom
Sequence
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Introduction
EN | 1-1
CHAPTER 1
Introduction
Digital video recorder for security applications
The Divar is a video recording system that can record multiple camera signals
while simultaneously providing live multiscreen viewing and playback. It
combines the functionality of a digital recorder with a multiplexer and a
switcher.
The unit has comprehensive search (including a smart motion search) and
playback facilities for viewing stored video. Once set up, all recording takes
place in the background without requiring operator intervention. Maximum
recording rates of 60 (NTSC) and 50 (PAL) images per second in total are
guaranteed with unsynchronized cameras. The recording rate and quality are
selectable per camera.
All models have extensive alarm handling functions and telemetry control.
Alarm functions include motion detection in user-definable areas of the image
on any camera input.
The unit can be easily operated and programmed via the front panel control
keys and on-screen display menu system. One monitor output provides full-
screen, quad and multiscreen viewing; another spot/alarm monitoring. A
keyboard can be connected for PTZ control and to improve the ease-of-use.
Via a network, the Control Center PC-application can be used for live viewing,
playback and configuration. Six simultaneous users can control multiple Divars.
The Divar includes an authenticity check for both local and remote playback. A
dedicated PC player is provided for playback of secure video files. Additionally,
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Introduction
EN | 1-2
a web browser on a PC can be used to view live images or playback recordings
from a Divar. The PC-based Configuration Tool facilitates the setup of the unit.
triple (***) asterix respectively. If your unit has neither of these facilities, then
please skip these instructions.
ATM/POS transaction data can be recorded and viewed if the Divar is
connected to an ATM or POS device via an ATM/POS bridge unit and has a
license installed.
Features
Looping auto-terminating video inputs, video outputs, alarm inputs and outputs,
and remote control connectors are on the rear panel. The two monitor outputs
provide CVBS video signals in either NTSC or PAL. Monitor A displays full-
screen or multiscreen digital pictures that can be frozen and zoomed. Monitor B
displays live full-screen pictures.
The Divar has the following features:
•
6, 9 or 16 looped-through, auto-terminating camera inputs (with embedded
Bilinx communication facilities***).
•
•
•
•
•
•
•
Simultaneous recording and playback.
Smart motion search.
Internal hard disk video storage.
Versions
Narrow SCSI port for external SCSI storage expansion.
10/100Base-T Ethernet port for Ethernet connection and networking.
RS232 serial port for serial communications.
There are various Divar models; 6-channel, 9-channel and 16-channel, each with
various storage capacities. In addition, a Divar can have one or both of the
following:
External keyboard input and output ports for keyboard connection and
system expansion.
•
•
An internal DVD writer
Bilinx-enabled camera inputs
•
•
Dual monitor outputs.
Full-screen and various multiscreen display capabilities in live and playback
modes.
A Divar with an internal DVD writer allows you to make archives locally
without the need for a PC. The writer supports DVD+RW, DVD+R, CD-R and
CD-RW media.
•
•
•
•
•
•
•
•
•
•
Spot monitor output with sequencing and OSD.
Motion detection.
A Divar Bilinx supports the use of Bilinx cameras. Bilinx technology embeds
control commands in the video signal enabling direct camera access and control
through a single video coaxial cable.
16 switching (alarm) inputs and 4 alarm outputs.
Compatibility with Bosch D9000 series control panels.
Video loss detection.
This manual describes the 16-channel version with an internal DVD writer and
Bilinx-enabled camera inputs.
Audible alarm.
Automatic protection of video clips on input alarm.
Pan, tilt and zoom camera control.
Internal DVD writer**.
Both 6-channel and 9-channel versions operate in exactly the same way except
that fewer cameras can be connected, there are fewer camera keys and the
number of multiscreen views is reduced. Instructions that only apply to the
internal DVD writer or Bilinx functionality are indicated by a double (**) or
Supports ATM/POS devices (external bridge required).
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Introduction
EN | 1-3
•
•
A 25-pin D-type connector board with screw terminals (used for switching
and alarm connections)
On-screen help
On-screen context-sensitive help is available for all topics. Just press the yellow
A 15-pin D-type connector board with screw terminals (used for PTZ
connections)
ALT key
for at least one second to see the help text associated with your
current activity. Press the escape key
to exit help.
•
•
•
•
•
•
•
Power supply cord
Network cross-over cable
For more information please visit:
Serial RS232 cross-over (null-modem) cable
Divar loop-through cable
Rack mounting kit
A CD-ROM with the software and the manuals.
Unpacking
SCSI terminator** (mounted on the SCSI connector; do not remove unless
an external SCSI device is to be connected).
Check the package for visible damage. If any items appear to have been
damaged in shipment, notify the shipping company. Unpack carefully. This is
electronic equipment and should be handled with care to prevent damage to the
unit. Do not attempt to use the unit if any components are damaged. If any
items are missing, notify your Customer Service Representative or Bosch
Security Systems Sales Representative.
Installation environment
Mounting: The Divar is supplied as a desktop unit. If desired, the unit may be
rack mounted using the rack mounting kit supplied with the unit.
The shipping carton is the safest container in which to transport the unit. Save it
and all packing materials for future use. If the unit must be returned, use the
original packing materials.
Ventilation: Ensure that the location planned for the installation of the unit is
well ventilated. Take note of the locations of the cooling vents in the unit's
enclosure and ensure that they are not obstructed.
Package contents
Temperature: Observe the unit's ambient temperature specifications when
choosing an installation space. Extremes of heat or cold beyond the specified
operating temperature limits may cause the unit to fail. Do not install the unit on
top of hot equipment.
Check for the following items:
•
•
•
•
•
Digital Video Recorder (Divar 16, Divar 9 or Divar 6 unit)
Quick reference guide
Divar operation manual
Power Supply: Ensure that the site's AC power supply is stable and within the
rated voltage of the unit. If the site's AC power is likely to have spikes or power
dips, use power line conditioning or an uninterruptable power supply (UPS).
Divar Control Center and Archive Player operation manual
Installation manual (this manual)
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Introduction
EN | 1-4
Associated equipment
DVD writer**
A typical system could contain the following components (not included with the
unit):
The following points should be taken into consideration when using the internal
DVD writer:
•
•
•
•
A primary monitor for multiscreen monitoring (monitor A).
A second monitor for spot/alarm monitoring (monitor B).
Cameras with 1 Vpp composite video outputs.
•
The DVD writer might not support all CD and DVD media. For a list of
approved CD and DVD media (not supplied by Bosch), please visit
•
•
After making an archive with the DVD writer, we advise you to test the CD
or DVD media to verify that the archived data can be played back on a PC.
75-ohm BNC connectors and video coaxial cable for connecting the video
signals.
To update the Archive Player software that is written to a CD/DVD when a
local archive is made, insert the supplied CD into the DVD writer. The
Divar automatically detects new Archive Player software. Follow the
instructions that appear on your monitor screen to load the latest Archive
Player software.
•
AC power supply outlet for the unit that allows for secure isolation. (The unit
has no on/off switch for security reasons.)
•
•
•
•
•
•
A keyboard (KBD-Digital).
PC for Control Center and Configuration Tool applications.
Pan/tilt/zoom control units.
•
The DVD writer supports the following write speeds:
DVD+R / DVD+RW: 4x (or higher)
Bosch D9000 series control panels.
CD-R:
CD-RW:
40x (or higher)
24x (or higher)
SCSI cable for connection to external storage devices.
External storage devices (DVAD LP Storage Array or DVAS RAID Storage
Array).
•
•
•
Video Manager for system expansion.
ATM/POS bridge for connecting ATM/POS devices.
Bosch Security Systems external DVD writer for local archiving for Divars
without internal writer.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Quick install
EN | 2-1
CHAPTER 2
Quick install
This chapter gives instructions on how to quickly get the unit operational. Make
the connections described on the following pages and then enter the relevant
data in the quick install menu.
The Quick Install menu appears the first time you start the unit. When you have
entered the relevant information the unit will be operational.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Quick install
EN | 2-2
Quick connection
DIVAR / 390 Ohm
6
ATM/POS
bridge
1
PC
x16*
AutoDome
LAN / WAN
8
RS232
9
7
Terminator**
Storage Array
11
R
E
L
SHIELD
1A
1B
2A
2B
3A
3B
4A
4B
+
-
CTRL
1
A
Y
SHIELD
+
-
GND
CTRL
2
1
2
9
10
IN
SHIELD
+
-
GND
CTRL
3
3
4
11
12
IN
SHIELD
+
-
GND
CTRL
4
5
6
13
14
IN
SHIELD
+
-
GND
CTRL
5
7
8
15
16
IN
SHIELD
AutoDome
4
5
110 - 240 Vac
2
3
A
B
*can be 6, 9 or 16 depending on model
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Quick install
EN | 2-3
Primary connections
First-time use
1. Connect the cameras to the BNC loop-through camera inputs (automatically
terminated).
2. Connect monitor A to the BNC output MON A.
The unit starts with a multiscreen display. The Quick install menu opens the first
time you use the unit. Fill in these basic settings to get the unit operational.
Select the Install item to save your settings and close the menu. When you close
the Quick install menu, the unit begins recording automatically.
Optional connections
To open the Quick install menu at any other time:
1. Press the ALT key
to enter the alternate function mode.
3. Connect monitor B to the BNC output MON B.
4. Connect up to 16 (alarm) inputs via the supplied 25-pin D-type connector
board.
5. Connect up to 4 alarm output relays via the supplied 25-pin D-type connector
board.
6. Connect a keyboard unit to the KBD IN socket.
> The ALT indicator lights.
2. Press the menu key
.
> The main menu appears full-screen on monitor A.
Select the System settings menu and then the Quick install submenu.
7. Connect a pan/tilt/zoom control unit via the supplied 15-pole D-type
connector board
8. Connect to your network via the Ethernet port or use the RS232 connector to
connect directly to a PC serial port.
9. Connect an external storage unit via the narrow 50-pin high density SCSI-2
port. (For Divars with an internal DVD writer: Do not remove the supplied
terminator from the SCSI connector unless you connect a disk array! )
Navigating
•
•
•
Use the arrow keys to move through a menu or list.
Use the select key
Use the escape key
to select a submenu or item.
to go back or to switch off the menu.
Powering up
10. Switch on all connected equipment.
11. Connect the power cord to the unit.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Quick install
EN | 2-4
>>DATE
•
QUICK INSTALL MENU >
Fill in the actual date.
QUICK INSTALL
LANGUAGE
TIME ZONE
TIME FORMAT
TIME
ENGLISH
>>ACTIVE CAMS
•
Select the cameras you wish to activate. Only activated cameras are
configured after exiting the Quick Install menu. Press the camera keys to
select or deselect a camera. A check mark means selected.
GMT +01:00 WEST EUROPE
24-HOUR
19:45:00
DATE FORMAT
DATE
YYYY-MM-DD
>>ALARM MONITOR
•
2002-06-20
Select the monitor on which input alarm messages are displayed.
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16
ACTIVE CAMS
>>RECORDING SETTINGS
•
Opens recording settings submenu to fill in the basic recording settings
for the day and weekend/night profiles.
ALARM MONITOR
MON A ONLY
RECORDING SETTINGS
NETWORK SETTINGS
>
>
>>NETWORK SETTINGS
Opens network settings submenu to fill in the settings that control the
behavior of the unit with respect to a network.
•
SAVE & EXIT
CANCEL
>
>>SAVE & EXIT
Select this item to load the settings you have made into the unit and exit
the Quick Install.
•
>>LANGUAGE
•
Select the language for the menu from the list.
>>CANCEL
Select this item to exit the Quick Install without saving.
•
>>TIME ZONE
•
Select a time zone from the list.
>>TIME FORMAT
•
Select either a 12 or a 24 hour clock format.
>>TIME
•
Fill in the actual time.
>>DATE FORMAT
•
Select from three date formats which show either the month (MM), the
day (DD) or the year (YYYY) first.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Quick install
EN | 2-5
•
Set the recording speed to NEVER to not record a camera at all. No pre-
alarm recording is done and the camera cannot be viewed over the
network.
>>RECORDING SETTINGS
RECORDING SETTINGS
DAY PERIOD
8:00
18:00
SAT AND SUN
1 IPS/CAM
2 IPS/CAM
DAY/NIGHT
12.5 IPS/INPUT
NIGHT
WEEKEND
>>REC WEEKEND/NIGHT
REC DAY
•
•
•
•
Select the normal recording speed to be used for each of the activated
cameras during the weekend/night profile.
REC WEEKEND/NIGHT
ENABLE ALARM INPUTS FOR
ALARM INPUT RECORDING
ENABLE MOTION FOR
The Images Per Second (IPS) rates available for PAL range from Never,
0, 1/10 (one image every 10 seconds), up to 25 IPS.
The Images Per Second (IPS) rates available for NTSC range from Never,
0, 1/10 (one image every 10 seconds), up to 30 IPS.
Set the recording speed to NEVER to not record a camera at all. No pre-
alarm recording is done and the camera cannot be viewed over the
network.
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16
MOTION RECORDING
5 IPS/CAM
036 HOURS
APPROX. REC. DURATION
>>ENABLE ALARM INPUTS FOR
•
•
Select the profiles during which alarm inputs are enabled.
Choose day only, weekend/night only, both day and weekend/night or
none.
>>DAY PERIOD
•
Fill in a start time and an end time to define the period during which the
day profile is active.
>>ALARM INPUT RECORDING
•
The weekend/night profile is active for the rest of the 24-hour period.
•
An activated input alarm can increase the recording speed of a camera.
Select the recording speed to be used when an input is activated.
The camera with the number that corresponds to the alarm input
number is recorded at the speed you set.
>>WEEKEND
•
•
When a day is defined as a weekend day, then the weekend/night profile
is active that whole day.
•
•
Define the weekend as either Saturday and Sunday or just Sunday.
Select none if you wish the weekend to be the same as the other days of
the week.
>>ENABLE MOTION FOR
•
Select the profiles during which motion events are enabled Choose day,
weekend/night, both day and weekend/night or none.
•
Press the camera keys to select or deselect the cameras for which motion
should be enabled. A check mark means enabled.
>>REC DAY
•
•
•
Select the normal recording speed to be used for each of the activated
cameras during the day profile.
The Images Per Second (IPS) rates available for PAL range from Never,
0, 1/10 (one image every 10 seconds), up to 25 IPS.
The Images Per Second (IPS) rates available for NTSC range from Never,
0, 1/10 (one image every 10 seconds), up to 30 IPS.
>>MOTION RECORDING
A camera can be recorded at an increased recording speed when motion
•
is detected. Select the recording speed to be used for each of the cameras
when motion is detected.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Quick install
EN | 2-6
>>APPROXIMATE RECORDING DURATION
>>BANDWIDTH LIMIT
•
•
•
•
This is an estimate of the recording duration based on the total amount of
storage space available and the recording setup. For event recording, the
following parameters are used:
During the day, one camera is in input alarm recording 5% of the time
and every motion enabled camera is in motion recording 10% of the
time.
Restrict the network bandwidth by entering an MBPS between 0 and 100
for the bandwidth limit.
During the night and weekend, one camera is in input alarm recording
1% of the time and in motion recording for 3% of the time.
>>NETWORK SETTINGS
NETWORK SETTINGS
DHCP
NO
DVR NAME
DIVAR
IP ADDRESS
192.168. 10.2
255.255.255. 0
0. 0. 0. 0
00:00:00:00:00:00
100 MBPS
SUBNET MASK
DEFAULT GATEWAY
MAC ADDRESS
BANDWIDTH LIMIT
>>DHCP
•
Set DHCP to Yes to have IP address, subnet mask and default gateway
assigned automatically by the network server. The actual values are
displayed.
>>DVR NAME
•
Enter a Divar name to be used in the network.
>>IP ADDRESS, SUBNET MASK AND DEFAULT GATEWAY
•
Fill in the IP, subnet mask and default gateway addresses when DHCP is
set to No.
>>MAC ADDRESS
•
The MAC address is read only.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Operating instructions
EN | 3-1
CHAPTER 3
Operating instructions
The instructions in this chapter explain the purpose of the front panel keys. The
functions available can be limited by setting passwords. Some functions may also
require a software license.
An administrator has access to many more functions in the menu. Refer to
Chapter 5 - Advanced Menu Setup for a full list of available menu items.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Operating instructions
EN | 3-2
Front panel controls
Divar Bilinx
Divar Bilinx
Divar Bilinx with internal DVD writer
DVD writer Open/Close button
DVD writer Read/Write LED
Divar Bilinx
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Operating instructions
EN | 3-3
Indicators
Keys
The keys on the front panel can be used for controlling primary functions or
alternate functions. Symbols for the primary functions are shown above the keys.
Symbols for the alternate functions are shown below the keys.
The power indicator
unit.
lights to indicate that power is being supplied to the
The indicators across the top of the controls light or flash to alert you to various
operating conditions.
The alternate functions are activated by first pressing the ALT key
and then
the desired key. When the alternate function mode is active, the light below the
ALT key is lit.
Record
Network
Alarm
-
-
-
-
-
lights when the unit is recording video.
lights when a remote user is connected to the unit.
flashes when an alarm is detected.
The unit automatically exits the alternate mode if the monitor A key
monitor B key or sequence key is pressed. When in a menu, the keys
operate according to their alternate function.
,
Motion
Video loss
flashes when motion is detected in a camera signal.
flashes when a video loss condition is detected for a
camera input.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Operating instructions
EN | 3-4
Primary functions
(light below ALT key off)
Live key
-
-
press to switch to live viewing.
ACK key
-
press when flashing to acknowledge an alarm.
Search key
press to open a search menu to look for recorded
events.
Multiscreen key- press to see different monitor display layouts.
ALT key
-
-
switches the front panel keys between a normal
function and an alternate function (shown below the
key).
press for longer than one second to get on-screen
help.
Reverse key
Pause key
-
in live mode, press to start reverse playback of
recordings for the displayed cameras.
in playback mode, press to speed up rewind.
in pause mode, press to step back one frame.
-
-
-
-
in live mode, press to freeze a camera picture.
in the playback mode, press to freeze playback
picture; press for longer than one second to protect
recordings or archive them to a DVD or CD.
1 - 16 Camera keys
-
-
-
press to see a full-screen display of the camera’s
picture.
in the menu mode, press to select the camera or
enter a password.
press current camera key to switch the display of the
ATM/POS data on and off.
Play key
-
in live mode, press to resume playback from the last
used playback position.
-
-
in pause mode, press to resume playback.
Fast forward
in live mode, press to start playback from one
minute earlier.
-
-
in playback mode, press to speed up the playback
rate.
in pause mode, press to step forward one frame.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Operating instructions
EN | 3-5
Alternate functions
(light below ALT key is lit)
F1 key
F2 key
-
-
restores defaults in active menu.
Menu key
Mon A key
Mon B key
-
-
-
opens the menu system.
is assigned a specific function in some submenus.
assigns front panel keys to monitor A.
assigns front panel keys to monitor B.
Arrow keys:
-
-
-
-
-
move around through menu items or values.
Sequence key - view cameras in sequence on full-screen or quad
displays.
Left
Up
Zoom key
-
zooms in on the active camera display (full-screen or
active cameo).
Down
Right
Select key
ESC key
-
selects a submenu or menu item, or saves selections
made in menus.
-
-
press to return to previous level or to exit menu
system without saving.
press to leave help system.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Operating instructions
EN | 3-6
Viewing pictures
The unit has two monitor outputs, A and B. The way in which these monitors
display pictures depends on how the system has been set up.
Viewing
The drawing shows all possible views for monitor A. Some multiscreen views
may have been disabled during set-up. The Divar model and the number of
connected cameras can also influence the multiscreen views available.
Monitor A
Monitor A is the main monitor. It shows full-screen, quad or multiscreen live or
playback camera pictures. Status messages, alarms, motion, and video loss
warnings are also displayed on this monitor. When the menu system is activated
it is displayed on this monitor.
4x4
12+1
4+3
1
5
2
6
3
7
4
8
1
5
2
3
7
4
8
1
4
2
5
3
7
6
1
Monitor B
9
10
14
11
15
12
16
10
12
11
13
9
9
6
Monitor B displays a single full-screen picture of a selected camera or a
sequence of full-screen pictures. When an alarm or motion input is detected, the
camera picture with the Alarm/Motion indicator can be displayed on monitor B.
When multiple alarms or motion occur, camera pictures are sequenced on
monitor B.
13
3x3
2
8+2
5+1
1
5
2
6
3
7
4
8
1
3
2
3
1
3
2
4
1
4
7
5
8
6
9
10
5
6
4
Selecting a monitor to control
To control the display on monitor A:
The quad mode can have 4 different quad screens that can be shown in
sequence to display 16 camera pictures.
1. Check that the light
on the front panel is lit.
2. If is not lit, press the ALT key
and then press the monitor A key
.
.
To control the display on monitor B:
1. Check that the light
on the front panel is lit.
2. If
is not lit, press the ALT key
and then press the monitor B key
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Operating instructions
EN | 3-7
Multiscreen
Cameo assignment
To view different multiscreen displays on monitor A:
Assigning cameras to cameos in a multiscreen view:
1. Press the multiscreen key
.
1. Press the ALT key
and then the multiscreen key
.
> A multiscreen display of camera pictures appears on monitor A.
> The multiscreen key indicator flashes.
> The border around the active cameo is green.
> The camera key of the camera shown in the active cameo lights (green).
2. Press the multiscreen key
multiscreen view.
again to go to the next programmed
2. Use the arrow keys if you wish to select a different cameo.
3. Press a camera key to display that camera’s picture in the active cameo.
> If you continue to press the multiscreen key
enabled multiscreen views.
, the unit cycles through all
> The camera is assigned and the following cameo becomes active.
4. Continue to press camera keys to assign camera pictures to cameos.
5. Press the ALT key
mode.
to interrupt cameo assignment and exit the assignment
Full-screen
To view a full-screen shot of a camera:
1. Press a camera key.
> The assignment mode is automatically ended when the last cameo has been
assigned.
The cameo assignment that you make is used in playback mode as well as in live
mode.
> A full-screen shot of the camera you selected appears.
> The camera key of the selected camera lights (green).
2. Press the multiscreen key
monitor A.
to go back to your previous multiscreen view on
Image freeze
Freezing a camera shot on monitor A:
Sequence
1. Press the pause key
2. Press the pause key
to freeze the picture in the active cameo.
again to return to live viewing.
To view a sequence of live camera pictures of several cameras:
If you are viewing a camera picture in full-screen mode, then this picture is
frozen. The zoom function can be used on a frozen picture. If you change
viewing mode, any frozen pictures are released.
1. Press the ALT key
> The indicator lights.
> A sequence of camera pictures appears, each for a pre-programmed dwell time.
2. Press the ALT key and then the sequence key to stop sequencing.
and then the sequence key
.
> Zooming, pressing the multiscreen key or selecting a single camera also stops
sequencing.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Operating instructions
EN | 3-8
Zoom
To zoom in on a camera picture:
1. Press the ALT key
> The ALT indicator lights.
2. Press the zoom key
.
.
> The zoom indicator lights.
> The picture is enlarged by a factor of 2.
3. Use the arrow keys to select the area of the picture to be displayed.
4. Press the zoom key
again to zoom in further.
> The picture is enlarged by a factor of 4.
5. Use the arrow keys to select the area of the picture you want to see.
6. Press the zoom key
mode.
again to return to a full picture and leave the zoom
> The zoom indicator no longer lights.
7. Press the ALT key
to return the keys to normal operation.
> The ALT indicator no longer lights.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Operating instructions
EN | 3-9
Live, playback and search modes
Live mode
Playback mode
The live mode is the normal operating mode of the unit where you watch live
pictures from the cameras. From the live mode you can switch to the search
mode, the playback mode or to the system menu.
In playback mode the video control keys operate as follows:
•
Press the rewind key
to start reverse play of recordings. Pressing it again
and again increases the display rate to a maximum and then back to normal
speed again. Press the rewind key
field at a time.
in the pause mode to step back one
Access to search and playback functions may require a password. Discuss this
with your administrator.
•
•
Press the pause key
to freeze the picture.
Press the search key
to switch to the search mode. The search menu opens.
Press the forward key
to start forward playback of recordings. Pressing it
again and again increases the display rate to a maximum and then back to
To enter the playback mode use one of the following keys:
normal speed again. Press the forward key
forward one field at a time.
in the pause mode to step
•
Press the rewind key
displayed cameras.
to start reverse playback of recordings for the
•
•
Press the play key
to resume playback.
•
•
Press the forward key
to start playback from one minute earlier.
Press the current camera key to switch the ATM/POS display on and off.
Press the play key
position.
to resume playback from the last selected playback
Press the live key
to switch back to live viewing or press the search key
to switch to the search mode. In both cases, playback stops.
Press the live key
to switch back to live viewing. An alarm also switches the
unit back to live viewing.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Operating instructions
EN | 3-10
Protecting or archiving a video recording
Search mode
1. Press the pause key
for longer than one second during playback to mark
Press the search key
search for stored video recordings.
to open the search menu. Use the search menu to
the beginning of a video segment for protection or archiving.
> A dialog window appears.
> The time and date of the marker at which the video segment starts is shown.
PLAYBACK SEARCH
SEARCH EVENT FILTER
CAMERA
2. Press the select key
archive.
to continue playing the video you wish to protect or
ALARM/MOTION
ALL
3. During playback, press the pause key
mark the end of the video segment.
> A dialog window appears.
for longer than one second again to
START TIME
2002-03-14 13:00
2002-03-14 14:00
FORWARD
END TIME
SEARCH DIRECTION
> The date and time of the beginning and end markers of the video segment is
shown.
START SEARCH
>
4. Select Protect to protect the marked video from deletion. Select Archive to
write the marked video segment to a (re)writable disk. Select Protect &
Archive to do both.
DISK CONTENTS
EARLIEST TIME
LATEST TIME
2002-03-14 14:00
2002-06-19 20:23
The software required to play a video segment on a PC (the Archive Player) is
copied to the disk when a local archive is made. To ensure that this software is
present in the Divar, use the supplied CD-ROM to load the latest version of the
Archive Player into the Divar.
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16
FILTER
>>SEARCH CRITERIA
•
Set the Event filter to search for only alarm events, only motion events or
both.
•
•
Set to None so that the search is not restricted by events.
Set to Smart Motion Seach to search for motion in a designated area of
a particular camera picture.
•
•
Set to ATM/POS to search for transactions based on the text string you
enter.
Specify the cameras to search for. The selected cameras are shown at the
bottom of the menu with a check mark. Press a camera key to change the
selection. If Smart Motion Seach is selected, only a single camera can be
selected.
•
Select Forward to search from start time to end time or Backward to
search from end time to start time.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Operating instructions
EN | 3-11
•
•
•
Fill in a time and date from which to start the search.
PLAYBACK SEARCH
SEARCH RESULTS
CAMERA 1
Fill in an end time and date to limit the time span of the search.
If ATM/POS is selected, fill in the text string (16 characters maximum)
you wish to search for. This text string is case insensitive.
Select Start Search (or press F2) to initiate the search procedure.
MOTION
2002-03-14 15:00:17
•
•
•
•
•
•
If Smart Motion Search is selected, you must set the motion sensitivity
and select an area before the search procedure is initiated.
Use the arrow keys to adjust the Motion Sensitivity. The higher the
value, the higher the sensitivity.
Select Motion Area to define the picture area that is to be examined for
motion.
Use the arrow keys to move around the grid. Press F1 to insert a motion
detection area. Use the arrow keys to enlarge it.
Press F1 again to save the area. Press the escape key to cancel and return
to grid square selection.
•
•
Press the select key to leave the grid. F2 clears all motion detection areas.
Select Start Search (or press F2) to initiate the search procedure.
•
Press the escape key
previous mode.
to exit the search mode and return to the
>>SEARCH RESULTS
•
The recording fitting the filter and closest to the selected date and time is
shown first.
•
Use the up/down arrow keys to move through a long list. The selected
recording is shown.
•
Press the select key
recording.
for a full-screen playback of the selected
•
•
Press the search key
Press the escape key
during playback to return to the list.
to return to the filter menu.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Operating instructions
EN | 3-12
Triggers and alarms
Various types of events can change the way the unit works. These events can be:
Background events
Triggers and alarms can change background tasks that you, as user, may not
even notice. Unit responses that are not visible to the user are, for example, a
change in recording speed, the activation of the output relay and event logging.
The unit can also be configured to record and automatically protect video clips
upon the activation of an alarm input. A trigger may change the way the camera
images are displayed on the monitors without requiring your intervention.
•
•
•
•
An alarm input signal applied to the unit.
Motion detection in a camera signal.
A loss of video from one of the cameras.
An internal alert from the unit itself.
The way the unit reacts to events depends on how it has been programmed.
An event can cause either a trigger or an alarm. A trigger can change the way
the unit works but does not require a response from the user. An alarm can also
change the way the unit works but, in addition, it usually activates several
indicators and requires that the user acknowledges the alarm situation.
The unit can react to an event in any one of the following ways:
Alarms
•
•
•
•
A beeper sounds
A status message is displayed
An alarm icon is displayed.
The border around a cameo can change color
•
An alarm indicator
The indicator flashes
An output relay is activated
,
, or
flashes
•
•
Alarms and Triggers
•
•
•
•
The view modes on the monitors change
A controllable camera is moved to a pre-defined position.
Recording speed changes
The unit changes the way it operates via pre-defined profiles.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Operating instructions
EN | 3-13
Alarm inputs
Motion alarm
If an input causes an alarm
If a motion detection signal causes an alarm
•
Monitors A and B can switch to a pre-programmed view mode.
•
Monitors A and B can switch to a pre-programmed view mode.
•
Monitor A: The border around the displayed cameos is red. The alarm icon
is displayed in each cameo. An alarm status message is displayed.
•
Monitor A: The border around the displayed cameos is yellow. The motion
icon is displayed in each cameo. An alarm status message is displayed.
•
Monitor B: Sequenced display of pre-programmed cameras.
•
Monitor B: Sequenced display of pre-programmed cameras.
•
•
The alarm beeper sounds. The alarm
and the
indicators flash.
•
•
The alarm beeper sounds. The motion
and the
indicators flash.
A controllable camera might be moved to a pre-defined position.
A controllable camera might be moved to a pre-defined position.
Acknowledging an input alarm
Acknowledging a motion alarm
1. Press the acknowledge key
to acknowledge the alarm.
1. Press the acknowledge key
to acknowledge the alarm.
> The beeper is silent.
> The beeper is silent.
> The alarm
and
indicators are no longer lit.
> The motion
and
indicators are no longer lit.
> The alarm status message disappears.
> The last-used view mode is restored.
> The alarm status message disappears.
> The last-used view mode is restored.
The alarm icon remains visible as long as the input causing the alarm is active.
The motion icon remains visible as long as the input causing the alarm is active.
If an alarm is not acknowledged, the beeper switches off after the dwell time but
the alarm still needs to be acknowledged.
If an alarm is not acknowledged, the beeper switches off after the dwell time but
the alarm still needs to be acknowledged.
If auto-acknowledge is enabled, the beeper, and the alarm
indicators switch off after the dwell time.
and
If auto-acknowledge is enabled, the beeper, and the motion
indicators switch off after the dwell time.
and
Using motion detection outdoors may cause false alarms because of varying
light conditions.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Operating instructions
EN | 3-14
Video loss alarm
Multiple alarms
Monitor A switches to multiscreen view if more than one alarm occurs. The
If the loss of a video signal causes an alarm:
Monitor A or B can be set up to show the video loss signal.
latest alarm status message is always shown. Pressing the acknowledge key
deactivates all alarms.
•
Monitor A switches to multiscreen view. The lost camera signal is displayed
as a black cameo with the video loss message. The border around the
camera with the video loss is red. An alarm status message is displayed.
Disk-full alarm
•
•
Monitor B: Sequenced display of cameras that do not have video loss.
The alarm beeper sounds.
A disk-full alarm message is displayed on monitor A and the alarm beeper
sounds.
•
The video loss
and the
indicators flash.
1. Press the acknowledge key
to acknowledge the disk-full alarm.
> The beeper is silent.
> The disk-full alert message disappears.
Acknowledging a video loss alarm
2. To avoid losing information, take corrective action to free disk space (for
example, archive and delete some recordings).
1. Press the acknowledge key
to acknowledge a video loss alarm.
> The beeper is silent.
> The video loss
and
indicators are no longer lit.
> The alarm status message disappears.
> The last-used view mode is restored.
If the camera with video loss is visible, the black cameo and the video loss
message continue to be displayed as long as there is no video present.
If an alarm is not acknowledged, the beeper, and the video loss
and
indicators switch off after the dwell time but the alarm still needs to be
acknowledged.
If auto-acknowledge is enabled, the beeper, and the video loss
indicators switch off after the dwell time.
and
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Hardware setup
EN | 4-1
CHAPTER 4
Hardware setup
This chapter contains detailed information about the connection of external
equipment to the unit. The connector types and their pin signals are described.
All the connectors are located at the rear panel of the unit.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Hardware setup
EN | 4-2
Rack mounting
Camera connections
Connect cameras to the unit using 75-ohm video coaxial cables with BNC
connectors. There are two BNC connectors for each camera. Either connector
can receive a camera's signal. This signal is looped-through (directly connected)
to the other connector, so that you can send the camera's signal to other
equipment. The camera input connectors are auto-terminating, so you do not
need to add a terminator to the output connector if no additional equipment is
connected.
The Divar can be mounted in a 19-inch rack. A rack mounting kit is supplied
with the unit that includes:
•
•
•
left and right rack mount ears
four Torx screws with integrated lock washers.
a Torx screwdriver
Mounting
If the camera signal is looped-through to additional equipment, make sure that
the end of the video line is terminated with a 75-ohm termination.
1. Remove the four Torx screws (two on each side) located near the front panel
on the right and left side of the housing.
The Divar automatically configures itself as a PAL or NTSC unit. The unit
determines the standard by detecting the signal format of the first connected
camera (lowest camera input number).
2. Attach the mounting ears to each side ensuring that the lip is under the unit.
Use the four Torx screws with lock washers and tighten securely.
Cameras that support the Bilinx communications standard can be directly
connected to the BNC connectors if your Divar version is Bilinx-enabled.
If Bilinx cameras are looped-through to multiple Divars, only one Divar is
allowed to have Bilinx enabled!
Specification
Input signal:
Composite video 1Vpp, 75 Ohm
Embedded Bilinx command protocol (Divar Bilinx only).
PAL/NTSC, auto-detect.
3. Install the unit into the rack using the rack manufacturer’s supplied hardware.
Color standard:
Gain control:
When installing the assembly into the rack, be careful not to restrict airflow
around the vent holes located in the side panels or to exceed the recommended
operating temperature.
Automatic or manual gain control for each video input.
BNC looped-through, automatic termination.
Connector type:
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Hardware setup
EN | 4-3
Monitor connections
Console port connection
Connect the unit to the monitors using 75-ohm video coaxial cables with BNC
connectors. The unit provides a 1Vpp CVBS signal.
The serial RS232 console port connector is used to connect a PC to the unit for
configuration or service purposes. Use a null-modem cable to connect the serial
port of the PC to the unit. The Baud rate can be selected in the menu system.
If the monitor has a loop-through connection and you are not using the loop-
through output, then select the 75-ohm impedance setting on the monitor. If the
monitor's loop-through output is connected to an additional device, the device's
termination is set to 75 ohms and the monitor's termination is set to high
impedance. (Note that this is not necessary on devices with automatic
termination.)
The serial RS232 console port connector is also used to connect Bosch D9000
series control panels via an interface unit for Divar alarm activation. Alarm
input mapping can be set up in the menu system.
Specification
Connector type:
9-pole D-type male connector
25V
Specifications
Output signal:
Maximum input voltage:
Communicaton protocol:
Composite video 1Vpp, 75 Ohm, Sync. 0.3Vpp 10%
Output signals according EIA/TIA-232-F
Resolution:
720 x 576 PAL, 720 X 484 NTSC
BNC
RS232 console port socket
Connector type:
Signal Name:
Pin no.
Description
DCD_in
1
2
3
4
5
6
7
8
9
Carrier detection signal (not used).
RS232 receive signal
RS232 transmit signal
No Connection
RX
TX
N/C
System Ground
System Ground
N/C
RTS
CTS
N/C
No Connection
RS232 request to send signal
RS232 clear to send signal
No Connection
5
9
1
6
Panel view
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Hardware setup
EN | 4-4
Keyboard In - RJ11 socket (KBD IN)
Keyboard connections
Pin no.
Signal
The keyboard input and output connectors are used to connect an external
keyboard to the unit. Connect the keyboard to the KBD IN connector. Up to 4
external keyboards can be connected when the optional keyboard port
expander (LTC2604) is used.
1
2
3
4
5
6
+12 V DC (11V Min to 12.6V Max, 400mA Max)
System ground
Keyboard plus line
Keyboard minus line
System ground
For short distances (up to 30m), standard 6-core telecom flat cable can be used
to supply power and signal connections for the keyboard.
System ground
For distances over 30m between keyboard and Divar, the Keyboard Extension
Kit (LTC 8557) must be used. This kit provides junction boxes, cables and the
appropriate power supply for the external keyboards. The recommended cable
type is Belden 9841 or equivalent.
Keyboard out - RJ11 socket (KBD OUT)
Pin no.
Signal
1
2
3
4
5
6
No Connection
System ground
Keyboard minus line
Keyboard plus line
System ground
No Connection
Divar connection
The KBD IN and KBD OUT connectors can also be used to connect several
Divar units to each other. The loop-through connector arrangement allows easy
interconnection of up to 30 Divars. The connection uses RS485-based
communications.
The RS485 connection is not galvanically separated. If you have an installation
where Divars are connected via RS485 and they are not located close to each
other, you must ensure that they are grounded via the same, clean grounding
wire.
6 1 4 2
Panel view
Specifications
Communicaton protocol:
Maximum signal voltage:
Power supply:
RS485
12V
11 - 12.6V, maximum 400mA
1.5 kilometers
Maximum cable length:
Cable type:
black (cross-over) cable (supplied with keyboard)
390 Ohm terminator
Termination:
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Hardware setup
EN | 4-5
LAN - RJ-45 Ethernet socket
Ethernet connection
Signal Name:
LAN_TX+
LAN_TX-
LAN_RX+
N/C
Pin no.
Description
The standard RJ-45 Ethernet socket is used to connect the unit directly to a PC
or to a network. The Ethernet is also used to connect to an ATM/POS bridge
unit. To connect directly to a network hub, use a straight-through network cable.
To connect directly to a PC, use the supplied cross-over network cable. Consult
with your local IT personnel for the specific type of cable needed. The cable
length from node to node is limited to 100 feet (30.5 meters) maximum length
and 6 feet (1.8 meters) minimum length.
1
2
3
4
5
6
7
8
Ethernet transmit line plus
Ethernet transmit line minus
Ethernet Receive line plus
No Connection
N/C
No Connection
LAN_RX-
N/C
Ethernet receive line minus
No Connection
Network configuration
The Divar is delivered with the DHCP function switched on, so IP addresses are
assigned automatically if the network server uses DHCP. (Refer to the System
settings/Connectivity/Network setup menu.)
N/C
No Connection
8
1
Specifications
Connection:
10/100 BaseT, IEEE 802.3
Panel view
Differential signal voltage:
2.8V max, inputs have transient overvoltage
protection.
Port details:
IEEE 802.3/802.3u - 100Base-TX/10Base-T physical
layer.
Auto Negotiation: 10/100, Full / Half Duplex
Cable length:
100 Meters: 100 Ohm unshielded twisted pair cable,
category 3/4/5.
100 Meters: 150 Ohm shielded twisted pair cable.
In-built compensation for impedance matching.
ACT, 10, 100
Impedance:
Indicators:
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Hardware setup
EN | 4-6
Specifications
Output impedence:
Overvoltage protection:
Control port
128 Ohm
30V max.
The control port is a bi-phase port for connecting the control units of
controllable cameras. Five bi-phase outputs are provided for dome camera and
pan, tilt and zoom control. The screw terminal connection board supplied with
the unit simplifies all bi-phase connections to the unit.
Differential voltage amplitude:1V min, 2V max. with a characteristic load of 220 Ohms
connected across the differential output
Cable length:
1.5 Kilometers max.
Belden 8760
Recommended cable:
Number of loads per output: 4 max.
1
9
8
Control port - 15-pole D-type socket
15
Signal name:
Code 1 -
Code 1 +
Shield
Pin no.
1
Description
Bi-phase control ch. 1 (minus)
Bi-phase control ch. 1 (plus)
System ground/cable shield.
Bi-phase control ch. 2 (minus)
Bi-phase control ch. 2 (plus)
System ground/cable shield.
Bi-phase control ch. 3 (minus)
Bi-phase control ch. 3 (plus)
System ground/cable shield.
Bi-phase control ch. 4 (minus)
Bi-phase control ch. 4 (plus)
System ground/cable shield.
Bi-phase control ch. 5 (minus)
Bi-phase control ch. 5 (plus)
System ground/cable shield.
2
3
Code 2 -
Code 2 +
Shield
4
5
SHIELD
CTRL 1
SHIELD
+
-
6
Code 3 -
Code 3 +
Shield
7
8
+
-
CTRL 2
SHIELD
CTRL 3
SHIELD
CTRL 4
SHIELD
CTRL 5
SHIELD
9
Code 4 -
Code 4 +
Shield
10
11
12
13
14
15
+
-
+
-
Code 5 -
Code 5 +
Shield
+
-
Panel view
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Hardware setup
EN | 4-7
Connecting the Inputs
External I/O connection
Each (alarm) input line can be switched by a relay contact from devices such as
pressure pads, passive infra-red detectors, smoke detectors and similar devices.
Wire them as either N/O or N/C. You can configure the alarm inputs as N/O or
N/C in the menu system. The default is N/O.
Alarm inputs and outputs are supplied via a 25-pole D-type socket. The screw
terminal input/output connection board supplied with the unit simplifies all
alarm connections to the unit.
Connecting the Alarm Outputs
1
13
25
The four alarm output relays respond to input alarms and triggers. You can
configure the alarm outputs as N/O or N/C in the menu system. The relays are
active for the duration of the driving event. Connect the application to the alarm
output relays (resistive loads only). Do not exceed 30 Vac, 40Vdc, 500 mA
(continuous) or 10VA on an alarm output relay's contacts. The contacts must not
be used at AC line voltages.
14
Specifications
Alarm input impedence:
Internal pull-up 10K to +5V
-0.3V min to 30V max
Low voltage 0.8V max
High voltage 2.4V min
Input voltage range:
R
E
L
1A
1B
2A
3A
3B
4A
Input voltage treshold:
A
2B Y 4B
GND
Switching current (resistive): 500mA max
Carrying power: 10VA max
1
2
9
10
IN
Switching voltage (resistive): 30 Vac / 40 Vdc max
GND
3
4
11
12
External I/O - 25-pole D-type socket
IN
GND
IN
Signal name:
Alarm_in_1
Alarm_in_2
Alarm_in_3
Alarm_in_4
Alarm_in_5
Pin no.
Description
5
6
13
14
GND
1
2
3
4
5
Alarm input 1
Alarm input 2
Alarm input 3
Alarm input 4
Alarm input 5
7
8
15
16
IN
Panel view
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Hardware setup
EN | 4-8
SCSI connection
Signal name:
Alarm_in_6
Alarm_in_7
Alarm_in_8
Alarm_in_9
Alarm_in_10
Alarm_in_11
Alarm_in_12
Alarm_in_13
Alarm_in_14
Alarm_in_15
Alarm_in_16
Relay1_A
Pin no.
6
Description
Alarm input 6
The unit provides a 50-pin high density SCSI-2 port for connection of an
external storage system, for example, a LP (DVAD) or a RAID (DVAS) storage
array. To use this feature, connect the drive's SCSI cable to the SCSI-2
connector on the rear panel.
7
Alarm input 7
8
Alarm input 8
9
Alarm input 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Alarm input 10
The Divar with internal DVD writer is delivered with a terminator connected to
the SCSI connector. Do not remove the supplied terminator from the SCSI
connector unless you connect a disk array!
Alarm input 11
Alarm input 12
Alarm input 13
The default SCSI ID of the Divar is 7. The SCSI ID of the internal DVD writer
is 6. If you are using a disk array make sure that the ID you select is different
from these IDs.
Alarm input 14
Alarm input 15
Adding additional storage arrays deletes all existing data!
Alarm input 16
Relay 1 output pole 1
Relay 1 output pole 2
Relay 2 output pole 1
Relay 2 output pole 2
Relay 3 output pole 1
Relay 3 output pole 2
Relay 4 output pole 1
Relay 4 output pole 2
Chassis Ground
Specification
Connector type:
Relay1_B
50-pin narrow SCSI connector for external SCSI device
Narrow (8 Bits) single-ended
Relay2_A
Bus format:
Relay2_B
Max. number of SCSI devices:6 (7 when Divar has no internal DVD writer)
Relay3_A
Max. transfer rate:
20 Mbytes per second
Relay3_B
Total max. cable length:
Fast-20
Relay4_A
2 to 4 SCSI devices
3m (uniformly spaced)
Relay4_B
5 to 6 (7) SCSI devices 1.5m (uniformly spaced)
System Ground
The internal SCSI cable length is approximately 17 cm.
This must be taken into account when calculating the
total cable length.
26
50
25
1
Panel view
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Hardware setup
EN | 4-9
Power Supply
Testing
Power is supplied to the unit via the IEC-style socket. The unit has no on/off
switch for security reasons. This means that the unit is always powered as long as
the power cable is connected from the unit to a live power socket.
In Live mode, select full-screen display for each camera and check the picture
quality. If the quality is poor, check:
•
•
•
The BNC connections.
Loop-through terminations.
Specifications:
Video levels of incoming signals and the possibility of ground loops.
Input Voltage:
100 - 240 Vac 10%
0.7A - 0.3A
Current:
Record for at least three minutes at the highest recording speed Then play back
the recording, selecting each camera for full-screen display in turn. Check the
playback picture quality. Check to see whether the programmed quality setting
is adequate.
Input Frequency:
50/60 Hz
Power supply socket
Signal
Pin no.
name:
Maintenance
Description
Maintenance of this unit is limited to external cleaning and inspection. Refer all
servicing to qualified personnel.
LIVE
1
2
3
AC live
NEUTRAL
PE
AC neutral
Protective Earth
WARNING!
Do not open the top cover or attempt to service the unit as this may expose you
to dangerous voltages and other hazards. Opening the unit will void the
warranty!
N
E
L
Panel view
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Hardware setup
EN | 4-10
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Menu system
EN | 5-1
CHAPTER 5
Menu system
You access all the parameters used to set up the unit via the menu system. The
large number of parameters available gives you the opportunity to program an
extensive functionality.
There are two ways of accessing the menu system, via the keys on the front of
the unit itself or via the PC-based Configuration Tool application. Using the
keys on the unit has the advantage of not requiring a PC and is the
recommended method if you are using the unit in a stand-alone configuration. If
you do have a PC connected to the unit or the unit is used in a network
environment, then the Configuration Tool offers a more convenient way of
accessing and using the menu.
In both cases the parameters available are the same. Slight differences in
navigation and selection are only due to the differences between the keys on the
unit and the keyboard and mouse interface of the PC. The menu structure is the
same in both cases.
This chapter explains how to use the keys on the unit to access the menus. It also
documents the full structure of the menu system. To find out how to use the PC-
based Configuration Tool refer to Chapter 6.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Menu system
EN | 5-2
Overview of the menu system
The main menu consists of six menu groups:
A profile determines how a unit behaves when that profile is active. Unit
behavior includes how events are handled. It also defines recording rates both
under normal conditions and in response to input and motion events.
History. The History menu allows you to trace all events that have occurred on
the unit.
Unit behavior can be set up differently for each of the six profiles. Profiles can
be named and copied to facilitate their setup and management.
Disk manager. The Disk Manager menu provides information and functions
that relate to the maintenance of the storage system including internal and
external hard disks.
Accessing the menu from the unit
Time/Date. The Time/Date menu is used to set the actual reference time and
date for the unit and the format that is used to display them.
To open the menu:
1. Press the ALT key
to enter the alternate function mode.
> The ALT indicator lights.
View settings. The View Settings menu is used to program how the individual
cameras are displayed on the monitors.
2. Press the menu key.
> The main menu appears full-screen on monitor A.
System settings. The System Settings menu is where most of the static
parameters for the unit are set.
Navigating
•
•
•
Use the arrow keys to move through a menu or list.
Profiles. The Profiles menu is used to set up and store the dynamic
characteristics of the unit.
Use the select key
Use the escape key
to select a submenu or item.
to go back.
Setting the dynamic characteristics
Access to some menu items can be password protected.
The settings in the Profiles menu provide the opportunity to tap the powerful
functionality of the unit. By spending some time in planning and setting up the
six profiles available, you can provide efficient use of resources while
maintaining effective cover for most types of working situations.
Profiles are usually based on a calendar, switching on and off at a particular date
or time (for example, weekends or night). Profiles can also be switched by an
input signal based on an external switch or armed alarm system.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Menu system
EN | 5-3
MAIN MENU
Main menu
History
The main menu gives access to six major menu groups. Each of these groups has
a submenu tree where the values and functions can be selected.
Disk manager
Time / Date
View settings
System settings
Profiles
•
Set Advanced Menus to Yes to see all items; set to No for standard
features only.
Advanced menus
MAIN MENU
History
View history list
HISTORY
>
>
>
>
>
>
DISK MANAGER
TIME / DATE
VIEW SETTINGS
SYSTEM SETTINGS
PROFILES
Disk manager
Status overview
Local archiving
Protected recordings
Authenticity check*
Stop recording
Storage setup*
Delete video
ADVANCED MENUS
NO
Erase disk
Time / Date
View settings
Camera setup
Sequences
Configure monitors
System settings
Language
Quick install
Record setup
Playback setup*
Event setup
History log setup
Local passwords
Connectivity*
Licenses*
Input and output contacts*
Factory defaults
Profiles
Currently active
Calendar setup
Profile override
Profile manager
System behavior
* advanced items
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Menu system
EN | 5-4
HISTORY >
DISK MANAGER >
The History menu provides a list of all events that have occurred. This list can
be filtered to show only those events you wish to see.
The Disk Manager menu gives access to information on the internal hard disk(s)
and any external disks connected. The status of the recorded video and
associated data is also accessed via this menu. Archiving is accessed via this
menu. Access to some menus may be password protected.
MAIN MENU
HISTORY
MAIN MENU
VIEW HISTORY LIST
BEGIN TIME
>
DISK MANAGER
2002-03-14 13:00
2002-06-19 20:23
STATUS OVERVIEW
LOCAL ARCHIVING
PROTECTED RECORDINGS
AUTHENTICITY CHECK
STOP RECORDING
STORAGE SETUP
>
>
>
>
>
>
>
>
END TIME
SHOW
ALARMS
YES
YES
YES
YES
MOTIONS
NETWORK CONNECTIVITY
ERRORS
DELETE VIDEO
ERASE DISK
EARLIEST TIME
LATEST TIME
2002-03-14 13:00
2002-06-19 20:23
>>STATUS OVERVIEW
•
•
Disk Capacity shows the total space available in Gigabytes.
Used Space shows the total space used by all video recordings including
protected recordings.
>>HISTORY FILTER
•
•
Fill in the date/time values to restrict the period for viewing events.
Select No for those events that you do not wish to see.
•
•
Protected Recordings Usage shows the space used by protected
recordings that cannot be overwritten.
The displayed Recording Time Left value depends on the recording
options that are set, and alarm and motion frequency. The estimated
recording time shown depends on the available storage capacity and
recording setup.
>>HISTORY LIST
•
•
•
•
The latest event is shown first.
Use the right/left arrow keys to move through a long history list.
If a date or time has been changed, the original values are also displayed.
Alarm, motion and video loss events are stored for a maximum of one
month.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Menu system
EN | 5-5
Add to Archive List
>>LOCAL ARCHIVING
•
Fill in a begin and end, date and time for the video segment you
wish to archive. Select Add to Archive List (or press F2) to place it
in the list. All recorded cameras in the time span are selected.
•
•
•
Segments of recorded video can be written to (re)writable disks using the
local archiving menu.
Select Archive Setup to check the status of the writer, the progress of the
writing, or to erase or format rewritable disks.
Select Archive Session to make a list of the video segments to be
archived and to start writing.
>>> Finalize
•
•
Set Finalize to Yes if the disk is to be finalized after archiving.
If a disk is not finalized it can be used for multiple sessions. If
finalized, older CD players can read it but new sessions cannot be
added anymore.
>>> Archive Setup
•
•
Progress is shown as a percentage of the current activity.
Select Cancel Archiving (or press F2) to stop the current archive
session (this can result in an unusable disk).
>>PROTECTED RECORDINGS
•
•
•
Set Finalize to Yes if the disk is to be finalized after archiving.
Select Erase Rewritable to remove all data from a rewritable disk.
Free Space shows the free space available on the inserted disk.
•
Move to a protected recording in the list and press the select key
play it back.
to
•
•
•
Press the escape key
to stop playback and return to the list.
Auto-protected recordings are indicated by a ! after the entry in the list.
To remove the protection of a recording, move to it in the list and press
F2. You must fill in a password (if configured) and confirm before the
recording is unprotected.
Select Add to Archive List (or press F1) to place a protected recoding in
the archive list.
>>> Archiving Session
•
Fill in a begin and end, date and time for the video segment you
wish to archive. Select Add to Archive List (or press F2) to place it
in the list. All recorded cameras in the time span are selected.
Select View Archive List to review the selected video segments and
to start the archiving procedure.
The archive list is saved until archiving is carried out. Video
segments that have been partially overwritten or deleted are
removed from the list.
•
•
•
•
Recordings to be archived are indicated by an A.
View Archive List
•
To remove a video segment from the list, select it with the arrow
keys and press F2.
Select Start Archiving to write the video segments to disk.
If the total size is greater than the disk capacity, then only the first
segments that fit are archived. Those segments that are not archived
remain in the list so that they can be archived to a new disk.
•
•
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Menu system
EN | 5-6
>>AUTHENTICITY CHECK
•
>>DELETE VIDEO
This check verifies that video images and associated data have not been
modified.
•
•
•
Delete recorded video by filling in an end date and time, and selecting
delete video.
All non-protected recordings made before the specified date and time are
deleted. You must confirm the deletion.
•
Select the period within which the authenticity check runs. The default
values are the same as the earliest and latest available recording times.
Protected recordings are not deleted.
•
•
•
Press the escape key
to cancel the check.
During the check all other front panel keys are disabled.
If the result is Not OK, the date and time of the tampered video is
displayed.
>>ERASE DISK
•
•
Deletes all recorded video on the disk.
You must confirm the deletion.
>>STOP RECORDING
•
•
•
•
•
•
Set the period for which you wish to temporarily stop recording.
The maximum period is one hour.
The duration counts down to zero.
Alarms are not recorded when recording is interrupted.
Interruption of recordings is always logged in the history list.
Recording starts automatically when interrupt period has elapsed.
>>STORAGE SETUP
•
•
•
•
Storage Setup gives an overview of internal and external storage.
The total disk space available is shown in Gigabytes.
Any new disks found are disabled by default.
Select the storage location you wish to enable or disable. All recorded
video is lost if you change a disk configuration. If you choose Yes to
continue, all video is erased.
•
Select Storage Status for an overview of the status of all internal and
external disks.
>>> Storage status
•
•
•
OK if everything is all right.
Fail if for some reason the disk is not working properly.
Fail - reconfigure storage if the disk is not part of the disk set or is
empty.
•
SCSI mismatch: change ID to X where X is the expected SCSI ID
and the SCSI ID needs to be changed.
•
•
Not found if the disk is not connected
Unused if a valid disk is found which is not used (disabled).
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Menu system
EN | 5-7
TIME/DATE >
VIEW SETTINGS >
The View Settings menu allows you to set up the display of the individual
cameras. You can also set the sequence in which the cameras are displayed and
the duration. Use the Configure Monitors submenu to set up the monitor
displays.
MAIN MENU
TIME/DATE
TIME ZONE
TIME FORMAT
TIME
GMT
+01:00 WEST-EUROPE
24 HOUR
14:00:17
MAIN MENU
DATE FORMAT
DATE
YYYY-MM-DD
2002-06-19
VIEW SETTINGS
CAMERA SETUP
SEQUENCES
>
>
>
SYNCHRONIZE
>
CONFIGURE MONITORS
DAYLIGHT SAVING
START DATE/TIME
END DATE/TIME
OFFSET
YES
>>CAMERA SETUP
LAST SUN MAR 02:00
LAST SUN SEP 03:00
01:00
Use the Camera Setup menu to access the submenus for setting the camera
names, for locking cameras and for controlling cameras.
•
Select a time zone from the list. (Daylight saving time is adjusted
accordingly.)
Fill in the actual time and date.
Select either a 12-hour or a 24-hour clock format.
Select from three date formats which show either the month (MM), the
day (DD) or the year (YYYY) first.
Set Daylight Saving to Yes to enable it. Fill in the day, month and time of
both change-overs and the offset if it differs from the information
associated with your time zone.
>>> Camera name
•
Select a camera by pressing a camera key on the unit. The number
•
•
•
of the camera is the number of the connector at the rear of the unit
to which it is connected.
•
Enter a name for the selected camera. The name can be up to 16
characters long.
•
>>> Camera lock-out
•
•
Locked cameras are not visible during normal use.
Place a check mark under the number of the camera you wish to
lock or press a camera key on the unit to switch the lock on or off.
Select the Set Password submenu and fill in a 4-digit password to
restrict access to the camera lock-out menu.
>>SYNCHRONIZE
•
Use the Synchronize function to set the time of the unit from the time of
•
the network. (Synchronize only works if the Divar time is within 7½
minutes of the server time.) Fill in the IP address of the network time
server.
•
The time and date of all other connected units are automatically
synchronized every hour from the time and date of the unit with DVR
ID 1.
>>> Camera control
•
Set the Auto Camera Contrast to On to let the system
automatically adjust the contrast for each camera.
If you set the Auto Camera Contrast to Off, you can access the
Adjust Contrast submenu.
•
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Menu system
EN | 5-8
Adjust contrast
>>> List Full screen monitor A
•
•
•
Select a camera in the menu or press a camera key on the unit. The
selected camera image appears.
Vary the manual gain value between -100 and +100 to adjust the
contrast.
•
The sequence list shows the order in which the camera images are
displayed in full screen mode (Control Center version 1 only).
Use the arrow keys to select a position in the list. Press a camera key
on the unit to enter a camera number in the list.
Press F2 to clear the rest of the list.
•
To set the default value (0), press the F1 key.
•
•
Press F1 to restore all defaults. Connected cameras are then listed in
ascending order.
>>> Camera controllable
•
•
•
A check mark under a camera number indicates that it can be
controlled remotely by the Control Center application.
Press a camera key on the unit to make a camera controllable or
not.
>>> List Full screen monitor B
•
The sequence list shows the order in which the camera images are
displayed in full screen mode (Control Center version 1 only).
Use the arrow keys to select a position in the list. Press a camera key
on the unit to enter a camera number in the list.
Press F2 to clear the rest of the list.
By default all cameras are controllable.
•
>>> Bilinx cameras
•
•
•
•
Only shown if your Divar is a Divar Bilinx.
A check mark under a camera number indicates that Bilinx control
is enabled.
Press F1 to restore all defaults. Connected cameras are then listed in
ascending order.
•
Press a camera key on the unit to enabled or disable Bilinx control
for that camera.
By default all cameras are enabled.
If Bilinx cameras are looped-through to multiple Divars, only
one Divar is allowed to have Bilinx enabled!
>>CONFIGURE MONITORS
•
•
•
To view camera names, and time and date on a monitor set these items to
On.
•
•
Set Motion Display to On to draw attention to any motion that occurs in
the designated zones.
Select the position for the text (top or bottom and fine position +11/-11).
Select text intensity. Select the border intensity of the cameos from four
values.
>>SEQUENCES
The sequence in which cameras are displayed on monitor A and monitor B is set
in the full screen list menu.
•
•
To automatically close the menu when an alarm or event occurs, set the
Exit Menu on Alarms item to Yes.
The menu is closed after five minutes if you set the Menu Time-out to
On.
•
Set the length of time each image remains on the screen by filling in the
dwell time value for each monitor.
Dwell time can vary from 1 to 60 seconds. The default value is 5 seconds.
•
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Menu system
EN | 5-9
SYSTEM SETTINGS >
>>> Multiscreen modes
•
•
•
Pressing the multiscreen key on the unit cycles through all enabled
multiple view modes.
Enable only those views you wish to see when you use the
multiscreen key.
The multiscreen modes that are available depend on the number of
cameras connected and the Divar model.
Use the System Settings menu to get access to those items that are used to
configure the system.
MAIN MENU
SYSTEM SETTINGS
LANGUAGE
ENGLISH
QUICK INSTALL
RECORDING SETUP
PLAYBACK SETUP
EVENT SETUP
>
>
>
>
>
>
>
>
>
>>> ATM/POS (requires bridge and license)
•
•
ATM/POS data is viewed on monitor A in full-screen mode only.
Select position, duration, text intensity and font size for display of
the ATM/POS data.
HISTORY LOG SETUP
LOCAL PASSWORDS
CONNECTIVITY
•
Press the current camera key during Live or Playback mode to
switch the ATM/POS data display on and off.
LICENSES
INPUT AND OUTPUT CONTACTS
FACTORY DEFAULTS
•
•
Select the language for the menu from the list.
Select Quick Install to quickly set up the system. The quick install menu
is described in Chapter 2.
•
If you select Factory Defaults, all settings in the menu system are reset to
their default value.
>>RECORDING SETUP
•
The continuous mode overwrites older recordings when the disk is full.
You can set an overwrite protection period of up to 15 weeks for the latest
recordings.
•
•
The linear mode first gives a warning and then stops recording when the
disk is full. Older recordings must be manually deleted.
Set the Pre-event time so that recording begins before an alarm is
activated. The maximum is 30 seconds.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Menu system
EN | 5-10
>>> Disk Full Alarm Setup
•
•
•
•
Set the percentage of used disk space at which the disk-full warning
message is displayed.
Set the time in minutes before the disk is full at which a disk-full
alarm is generated.
Select the number of the output relay that is activated when a disk-
full alarm is generated.
Enable the beeper to activate it when a disk-full alarm is generated.
•
•
Select the Input Name submenu to assign a name to each of the 16
Divar inputs.
If an alarm panel is connected to the RS232 port and enabled,
select the Alarm Input Mapping submenu to associate alarms from
the alarm panel with the 16 Divar inputs.
Select the Auto-protect submenu to choose automatic protection of
video clips activated by a specified input.
•
Display mon A
•
>>PLAYBACK SETUP
Select the input number (1 to 16) for which you wish to set the view
mode.
Use the Playback Setup list to block the playback of recordings from particular
cameras after a specified period of time.
•
If you have controllable cameras, set a camera number and a pre-
position number. The specified camera goes to this position when
the numbered input is activated.
•
Choose from No Block, 1 to 7 days, 14 days, 21 days, 28 days or 31 days.
When the specified time has elapsed, the recordings of that camera from
before that time cannot be played back.
•
•
Select a view mode. Only view modes that are enabled can be
selected.
If you have selected the full-screen or quad view mode, select the
cameras to be displayed.
>>EVENT SETUP
Use the Event Setup menu to specify the display behavior for an input, detected
motion or video loss.
Display mon B
•
•
•
•
Set the Alarm Dwell Time to select the period during which the output
relay and the beeper remain active after activation.
Set the Trigger Dwell Time to select the period during which the
triggered view mode is displayed after activation.
The value Follows activates the beeper and relay or view, only as long as
the event is present.
Select the input number (1 to 16) for which you wish to set the view
mode.
•
If you have controllable cameras, set a camera number and a pre-
position number. The specified camera goes to this position when
the numbered input is activated.
•
Select up to four cameras to be displayed in sequence.
Alarm Input Mapping
>>> Input Setup
•
•
•
Only shown if alarm panel is connected and enabled.
The control console type is displayed.
For each of the 16 alarm inputs, select either the physical Divar
input (the physical input is automattically mapped to its
corresponding alarm input number) or an input from the control
console (Alarm Panel 1 to Alarm Panel 238).
•
•
•
•
To restore the default input settings select the Clear Input Settings
item.
Select the Display Monitor submenu to choose the view mode and
cameras to be displayed when an input is activated.
Select the number of the output relay to be activated when any
alarm input is activated.
Enable the beeper to activate it when an alarm input is activated.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Menu system
EN | 5-11
Auto-protect
Display mon B
•
•
•
•
Four inputs can be used to trigger automatic protection of video
clips.
Select the inputs you want to use for each of these triggers. Set to
•
•
Select the camera number that generates the motion event.
If you have controllable cameras, set a camera number and a pre-
position number. The specified camera goes to this position when
motion is detected by the selected camera (not necessarily the
controllable camera).
None if you do not want automatic protection.
Select the length of time (1 to 60 minutes) that you want protected
before and after the event. These values are valid for all four inputs.
Select the percentage of hard disk space you want to reserve for
auto-protected recordings and the behaviour of the Divar if this
percentage is reached (warn only, stop auto-protect recording or
overwrite the oldest auto-protected clips).
•
Select up to four cameras to be displayed in sequence.
Motion area
•
•
Select a camera number.
The motion indicator shows the maximum level of camera motion
that has been detected for the defined area. Press F2 to clear it if
you want to re-test the level of motion detection.
Use the arrow keys to adjust the Trigger level slider to just below
the indicated motion level.
A motion detection signal is generated when the level of motion
reaches the trigger level set.
>>> Motion Setup
•
•
•
•
•
Using motion detection outdoors may cause false alarms because of
varying light conditions.
To restore the default motion settings select the Clear Motion
Settings item.
Select the Display Monitor submenu to set up the view mode and
cameras to be activated on the monitor for each motion event. The
Motion Area submenu sets the area and sensitivity for each camera.
Select the number of the output relay that is activated when motion
is detected.
Edit area
•
Select Motion Area to define the picture area where motion is
detected.
•
•
•
Use the arrow keys to move around the grid. Press F1 to insert a
motion detection area and use the arrow keys to enlarge it. Press F1
again to save the area. Press the escape key to cancel and return to
grid square selection.
Press the select key to leave the grid. F2 clears all motion detection
areas.
Enable the beeper to activate it when any motion is detected.
Display mon A
•
•
•
Select the camera number that generates the motion event.
If you have controllable cameras, set a camera number and a pre-
position number. The specified camera goes to this position when
motion is detected by the selected camera (not necessarily the
controllable camera).
Select a view mode. Only view modes that are enabled can be
selected.
>>> Video loss Setup
•
•
•
Select the monitor on which the camera with the video loss is
displayed.
Select the number of the output relay that is activated when video
loss occurs.
Enable the beeper to activate it when any video loss occurs.
•
•
If you have selected the full-screen or quad view mode, select the
cameras to be displayed.
>>HISTORY LOG SETUP
Select Yes for those events that you want to log in the history file.
•
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Menu system
EN | 5-12
•
•
The entire history list is erased if you select the Clear History item.
Date/time changes of stored video are always logged and cannot be
disabled or cleared.
>>> Network access
•
•
•
Access to the unit via the network can be set for up to six different
users.
Restrict access to the unit by listing an IP address range. The range
you use will normally depend on your network setup.
Select a user number to set up the configuration for that remote
user. The administrator is user 1 and is identified as
ADMINISTRATOR.
>>LOCAL PASSWORDS
•
•
Set or change the password that allows access to playback functions.
Set or change the password that allows access to the configuration
functions.
Use the camera keys (1 to 9) on the front of the unit to enter a four-digit
password in the dialog box that appears.
•
IP Range
•
•
Enter the same password again to have it verified.
Press F2 to remove password protection.
•
•
Eight IP ranges can be entered to allow access.
Enter the same begin and end address to specify a single IP address.
Enter different begin and end addresses to specify an IP address
range.
>>CONNECTIVITY
The Connectivity menu gives access to settings that control the behavior of the
unit with respect to all external devices or a network. It also gives access to
settings for connecting multiple units to each other and for connecting
computers via the communications port.
•
Use the up/down arrow keys to move to an IP entry. Press the select
key to edit the entries. Press F1 to set the default values
(000.000.000.000 to 255.255.255.255).
List of Users
Enter a name, up to 16-characters long, for each user. Enter a
password up to 12-digits long.
•
>>> Keyboard access restrictions
•
•
Four external keyboards can be connected to the unit.
Allow these keyboards to control monitor A only, monitor B only,
both or neither.
•
•
Set User Rights to Live to restrict viewing rights to live video only.
Select the cameras in the Camera Lock Out submenu that are not
accessible for the user.
•
•
Set the camera sequence list and dwell time (from 3 to 59 seconds)
for the remote viewer. All connected cameras are listed by default.
Set Camera Control to allow control of controllable cameras
remotely.
>>> Network setup
•
Set DHCP to Yes to have IP address, subnet mask and default
gateway assigned automatically by the network server. The actual
values are displayed.
Enter a Divar name to be used in the network.
Fill in the IP, subnet mask and default gateway addresses when
DHCP is set to No. If required, change the default http port (80) to
a new value. The MAC address is read only.
•
•
>>> Expand system
•
•
•
When you have multiple units linked, give each unit a unique
identification number (from 1 to 30).
Enter a first camera number (from 1 to 999) to offset the camera
numbers for the different Divars.
Only default camera identification numbers (Camera 1, Camera 2,
etc.) are offset.
•
•
If Discovery is set to Enabled, the Control Center can carry out
automatic discovery and read the IP address of the unit.
Restrict the network bandwidth by entering an Mbps between 0
and 100 for the bandwidth limit.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Menu system
EN | 5-13
PROFILES >
>>> COM port
•
The COM port is an RS232 serial port used mainly for connecting
a PC or an alarm panel to the unit.
Six different profiles can be stored. These profiles can be activated by an input
switch or by a date or time. The profiles contain configuration settings for
recording data, handling events and restricting access. You can define a calendar
that automatically selects profiles. These profiles can be configured for day,
night, weekend or holidays for example.
•
Most parameters are fixed. Select the appropriate baud rate.
>>> ATM/POS setup (requires bridge and license)
The list of all ATM/POS bridges connected to the unit shows the IP
address and the connection status.
•
MAIN MENU
PROFILES
•
Use the arrow keys to move to a bridge and select it to open a
terminal configuration menu for that bridge.
CURRENTLY ACTIVE
CALENDAR SETUP
PROFILE OVERRIDE
PROFILE MANAGER
SYSTEM BEHAVIOR
1
>
>
>
>
Terminal Setup
•
•
Edit the IP address of the selected bridge if required.
The names of all terminals connected to the bridge are shown with
their associated camera. Only data from terminals with an assigned
camera is stored.
>>CALENDAR SETUP
•
•
•
Use the arrow keys to move to a terminal and select it to open a list
of available cameras. Select a camera to assign it to the terminal. A
camera cannot be assigned to two terminals. A terminal can only
have a single camera assigned to it.
The use of profiles is defined in a calendar that covers one week. This
calendar is then repeated for subsequent weeks.
•
•
A profile is specified at intervals of 15 minutes for each day of the week.
You can program exception days to change profiles for special days and
holidays.
Press F1 to remove all camera assignments.
>>LICENSES
•
•
Fill-in the key of any additional licenses you purchase exactly as supplied.
The MAC address and a description of the installed licenses are shown at
the bottom of the menu-screen.
>>> Calendar edit
•
The Calendar Edit menu shows the profile identification numbers
used in a 24-hour period (0 to 23). Each hour is divided into four
15-minute periods.
To see the other days of the week use the left /right arrow keys.
Select the Add Schedule item to edit the calendar.
>>INPUT AND OUTPUT CONTACTS
•
•
•
•
•
The contacts of the input and output relays default to normally
open (N/O).
Place a check mark in the box under a specific relay to set its contacts to
normally closed (N/C).
•
Press a camera key to place or remove a check mark.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Menu system
EN | 5-14
Add schedule
•
>>> Profile override inputs
Select the profile name, the begin and end times, and the days on
which you want the profile to be active.
•
•
Six inputs can be set up to select a profile.
The active profile defined by the calendar and exception day
schedule is overridden by the input selection as long as the input is
active.
•
•
Only five profiles changes can occur in any one day.
Select a number from 0 to 23 for the hour. Select between 0, 15, 30
or 45 for the minutes.
•
•
Inputs used for other purposes cannot be used to select a profile.
An entry is set to empty by selecting it and pressing F2.
•
If the begin time is later than the end time, then the profile is active
from the end time until the begin time on the next day.
>>> Profile titles
Select a profile. Enter up to 4 characters to give a meaningful name
to the profile.
>>> Exception days
•
•
•
Up to 32 exception days can be set that override the calendar list.
Use the up/down keys to move to an exception entry and press the
select key to start editing. Enter the start date/time, the duration and
the profile name.
>>> Camera pre-position on profile change
•
•
Four controllable cameras can be set up for a profile change.
Enter the pre-position (PP00 to PP99) that each camera should
adopt when the profile is activated. Set to None for no change.
•
Press the F2 key to empty an entry.
>>PROFILE OVERRIDE
•
Select a different profile to manually override the active profile for a
>>SYSTEM BEHAVIOR
•
temporary period.
Use the System Behavior menu to configure the event handling, the
•
Set the duration for which you wish to override the active profile. The
maximum is 24 hours. If set to Always, the calendar is disabled
completely. If set to zero, the override function is disabled.
recording setup and the access restrictions for each of the six profiles.
Profile settings can be copied from one profile to another in the Copy
System Behavior submenu.
•
>>PROFILE MANAGER
>>> Event handling
•
•
•
The Profile Manager lists the scheduled and active profiles.
The Profile Override Inputs submenu sets up the inputs to switch
profiles.
Select the profile for which you wish to configure the event
handling.
•
Move to the line that you wish to change. Press the camera keys to
select an input or camera. Press the select key to enable or disable
the selection. A check mark means enabled.
Enabled selections act as triggers. If alarm is checked, the selection
acts as an alarm.
•
•
The Profiles Titles submenu assigns names to the six different profiles.
The Camera Pre-position on Profile Change submenu sets four
controllable cameras to a specified pre-position when the active profile is
changed to a different profile.
•
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Menu system
EN | 5-15
Input
>>> Output handling
•
Each input, when activated, can change the normal recording
behavior of up to four cameras for a maximum of 120 seconds.
Select the profile. Select the input number.
Select the cameras whose recording behavior should change. Set
the recording rates and quality levels for each camera. Set camera
name to None to use less than four cameras.
•
•
•
Select the profile for which you wish to configure the output
handling.
Select the number of the output relays to be activated when an
enabled event in the selected profile is activated.
Enable the beeper to activate it when an enabled event in the
selected profile is activated.
•
•
•
To free IPS bandwidth, the recording rate of cameras not in alarm
is limited to the IPS number displayed.
>>> Recording setup
•
Recording behavior for each of the six profiles is specified in three
Motion
•
submenus. The Normal submenu is for a normal situation without
alarms or motion events. The Input submenu is for input changes.
The Motion submenu is for motion events.
Each motion input, when activated, can change the normal
recording behavior of up to four cameras for a maximum of 120
seconds.
•
The list gives an overview of inputs and motions that are used in
any of the profiles. A check mark means used.
•
•
Select the profile. Select the motion camera number.
Select the cameras whose recording behavior should change. Set
the recording rates and quality levels for each camera. Set camera
name to None to use less than four cameras.
To free IPS bandwidth, the recording rate of cameras not in alarm
is limited to the IPS number displayed.
Normal
•
Select the profile. The Unallocated IPS item shows the IPS
capacity remaining.
•
•
A total of 60 images per second (IPS) can be recorded for NTSC;
50 IPS for PAL. A minimum of 1 IPS is always allocated per
camera for pre-alarm recording and network viewing.
Set the recording rates and quality levels for each camera. Quality is
standard, medium or high.
IPS rates for PAL range from Never, 0, 1/10 (one image every 10
seconds), up to 25 IPS.
IPS rates for NTSC range from Never, 0, 1/10 (one image every 10
seconds), up to 30 IPS.
Set the recording speed to NEVER to not record a camera at all.
No pre-alarm recording is done and the camera cannot be viewed
over the network. No ATM/POS data is recorded.
>>> Access restrictions
•
•
•
•
Remote access restrictions can be set for each of the six profiles.
•
•
•
•
Select the profile. Select if local playback is enabled or not.
Select which remote users have access and which are blocked.
Remote user 1, the administrator, always has access.
>>> Copy system behavior
To copy the settings of one profile to another, enter the number of
•
the source profile, enter the number of the destination profile and
select the Copy Now item.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Menu system
EN | 5-16
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Using the Configuration Tool
EN | 6-1
CHAPTER 6
Using the
Configuration Tool
The Configuration Tool is a software application that makes the installation and
configuration of a unit faster and easier. The Configuration Tool runs on a PC
that is connected to the Divar either directly via an RS232 serial connection or
via an Ethernet network connection.
Although all settings can also be configured with the on-screen display menu of
the Divar itself, the Configuration Tool offers a very user-friendly alternative. It
also allows configuration settings to be saved on the PC hard disk. These can be
restored later and used to configure other units.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Using the Configuration Tool
EN | 6-2
Getting started
To use the Configuration Tool to change settings, the unit must be physically
connected to a PC via the RS232 Console Port or via a network connection. The
Configuration Tool application must be installed on the PC.
Starting the Configuration Tool
Starting the Configuration Tool depends on how you are connected to the unit:
•
•
•
via a serial RS232 connection,
via a network, or
offline
System requirements
Operating platform:
A PC or compatible running Windows 95, Windows 98,
Windows Millennium, Windows NT 4.0 (SP4),
Windows 2000 or Windows XP.
Serial connection
If your PC is connected directly to the unit via the serial RS232 connection,
double click the Configuration Tool icon on your desktop window to start the
program. Select the Serial connection entry from the DVR list.
For the Configuration Tool application, the minimum PC requirements are:
•
•
•
•
•
Processor:
200 MHz Pentium with MMX (or equivalent)
32 MB (depends on operating system)
15 MB free
RAM memory:
Hard disk space:
Video system:
Connectivity:
Network connection
To start the Configuration Tool without using the Control Center, double click
the Configuration Tool icon on your desktop window to start the program.
Alternatively, select the Divar Configuration Tool program via the Start button
on the task bar and the Programs menu item. Follow the login procedure.
800x600 with 16-bit color
A free RS232 port or a 10/100-BaseT network interface
Installing the Configuration Tool
To start the Configuration Tool via the Control Center, click the Config button
in the Control Center window. You must first be logged into the Control Center
as an administrator to open the Configuration Tool in this way.
The Configuration Tool is automatically installed on the PC when you install the
Control Center application. To install separately:
1. Insert the CD-ROM into the CD-ROM drive on your PC.
> The installation program starts automatically.
Offline configuration
If you choose to log in with an offline configuration, you should select the Divar
version, model, the video standard and the cameras that are connected.
2. If installation does not start automatically, locate the Setup.exe file on the CD
and double click it.
3. Follow the instructions on the screen and select to install the Configuration
Tool when asked to complete the installation.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Using the Configuration Tool
EN | 6-3
How to Log in
When you start the Configuration Tool as a stand-alone application via a
network, the Login window appears. (Click Cancel to discontinue login and exit
the application.)
To automatically detect all enabled Divars on the network:
1. Click Detect.
> To detect a Divar, Discovery must be enabled on that Divar.
2. Select a Divar and click OK to add the selected Divar to the list.
To add a Divar to the list:
1. Click Add.
2. Enter the IP address or nickname of the new Divar.
When the Configuration Tool application is started for the first time, the Divar
list is empty. You must first add a Divar to the list. To add a Divar to the list or to
modify a Divar entry, click Edit >> (see following paragraph).
> The IP address to be filled-in is set in the System settings/Connectivity/Network
setup menu of the Divar itself.
3. Type a name in the Name box or retrieve it from the Divar by checking the
Retrieve from Divar box.
4. Click Add.
To modify the Divar list
The Edit Divar list window allows you to add Divars to the list or delete Divars
from the list.
To delete a Divar from the list:
1. In the list, select the Divar you wish to delete.
2. Click Delete.
> The selected Divar is removed from the list.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Using the Configuration Tool
EN | 6-4
Login
Maximum number of users
If the maximum number of users for the Control Center is exceeded, a window
is displayed. An administrator can use this window to force off a user. The list
shows all users that are currently logged in.
When you start the Configuration tool application, the Login window appears.
(Click Cancel to discontinue login and exit the application.)
To disconnect a user:
1. Select a user in the list.
2. Click Yes.
Menu structure differences
The Configuration Tool allows you to access and use menu items of the unit.
These menu items are explained in Chapter 5. Although the items are the same,
the menu structure is slightly different in the Configuration Tool:
•
The History menu item is removed from the menu tree structure and is now
accessed via the History button.
•
The Disk manager submenu is replaced by the Storage setup item of the
menu tree structure in the Configuration Tool.
To control a particular Divar:
1. Select the Divars you want to control by placing check marks next to them.
As a result of the windows interface, selection and editing of some functions with
the Configuration Tool is different to the methods used on the unit itself. For
example, scroll bars are used instead of the arrow keys, the motion area
selection interface is simpler, and the Calendar edit item of the Profiles menu
uses a color code to add profiles to the calendar. The Configuration Tool
interface, although different, is intuitive and does not change the functionality of
the menu items.
> Click
to either select all or none of the Divars listed.
> If a login group has been defined, you can select this group to log in to the Divars
listed in the group.
2. Type your user name and password.
> The user name and password to be filled-in are set in the System settings/
Connectivity/Network access menu of the Divar itself. Check with your
administrator if you do not have access to the unit.
> To let the system remember your name and password on subsequent uses of the
Control Center, place a check mark in the Save login information box.
3. Click Login.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Using the Configuration Tool
EN | 6-5
Introducing the main window
The Configuration Tool window is divided into 3 panes. The buttons in the left
pane are always available. Clicking one of these buttons changes the contents of
the center pane. The buttons in the right pane are control buttons that give you
direct access to various tasks.
History button
Click the History button
list can be filtered to show only those events you want to see.
to display a list of events in the center pane. This
•
•
Fill in the date/time values to restrict the period for viewing events.
Uncheck those type of events that you do not wish to see.
The latest event is shown first. If a date or time has been changed, the original
values are also displayed. Press More to see more events.
Settings button
Click the Settings button
to display the menu for configuring the Divar.
The menu tree structure and the selected submenu is shown in the center pane.
Using the Menu tree
When you click the Settings button
, the menu tree is displayed on the left
of the center pane. Use this tree to navigate through the menu system.
•
•
•
•
•
Click + to expand the branch structure.
Click - to collapse it.
Click an entry to display the parameters for that menu item.
Select the values you want for the parameters.
These values are updated immediately.
Overview button
Click the Overview button
to get general information about the Divar that
is connected.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Using the Configuration Tool
EN | 6-6
Service button
Using the control buttons
The right side of the main window has several buttons that allow you to perform
common tasks quickly:
Click the Service button
the firmware update function. This function is only available if you are
connected to the unit via a serial connection and is password protected.
to get a list of diagnostic messages and to access
Import / Export
All settings that you set in the Configuration Tool can be saved in a file that is
stored on the PC disk. You can save as many of these files as you like, just give
them different names. The settings in these files can be loaded back into the
Configuration Tool either completely or in subgroups. Although these files are
stored as text files and can be viewed with a text viewer, do not change or edit
them as this makes them unusable.
Help button
Click the Help button
appears.
at any time to get help. A pop-up help window
Logout button
Import
To return to the Control Center application or to log on to different unit, click
the Logout button
1. Click the import button
to open a settings file.
2. In the dialog box, select the location and name of the file you want to open.
3. Select the groups of settings you want to load and click OK.
4. The selected settings are downloaded to the unit immediately
.
Export
1. Click the export button
to save the current settings in a PC file.
2. In the dialog box, select the location and enter a name for the file you want to
save.
3. Select the groups of settings you want to save and click OK to save the
settings.
Multiple download
Click the download button
to open a list of the Divars in the network to
which you can download selected settings. Select those Divars in the list that you
want to update.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Using the Configuration Tool
EN | 6-7
Refining settings
Save
When you select Import, Export or Download a pop-up window allows you to
select particular groups of settings. You can select All settings, All settings
except or Only to determine how the list is constructed. To refine your selection
When the Overview or History page is active, you can save the complete
contents of the page or list.
1. Click the save button
to save the current settings in a PC file.
click
and place a check mark next to the settings you want to include
2. In the Save dialog box, enter a file name and location.
3. Click OK to save.
in the list.
Refresh
The information is saved in a text file.
Click the refresh button
only.
to refresh the content of the current page settings
Clear
Click the clear button
values.
to set all settings on the active page to their default
Undo / Redo
Click these buttons to undo
can be undone.
or redo
your last action. Up to 100 actions
Previous / Next
Use these buttons to move through the settings menu.
Click the previous button
current page.
to go back to the page that was active before the
Click the next button
to activate the next page in the menu system.
Print
When the Overview or History page is active, you can print the complete
contents of the page or list.
1. Click the print button
to print the current settings.
2. Click OK to print.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Using the Configuration Tool
EN | 6-8
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Menu default values
EN | 7-1
CHAPTER 7
Menu default values
The table on the following pages lists the items of the menu system of the unit
with default values. The righthand column of the table gives the default values of
these menu items. These values are restored when the Factory defaults item of
the System settings menu is selected.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Menu default values
EN | 7-2
Level 1
History
Level 2
Level 3
Level 4
Level 5
Default value
Show alarms
Yes
Yes
Yes
Show motions
Show network
connectivity
Show errors
Yes
Time / Date
Time zone
GMT+01:00 Western
Europe (PAL)
GMT -06:00 Eastern
time (NTSC)
Time format
24-hour (PAL)
12-hour (NTSC)
Date format
Synchronize
YYYY-MM-DD
No
Use timer server
IP address
0. 0. 0. 0
Yes
Daylight saving
Camera setup
View Settings
Camera name
Select input
Title
01 . . . 16
CAMERA 1...CAMERA
16
Camera lock-out
Enter password (only when
set)
Camera list
No cameras locked
No password set
Set password
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Menu default values
EN | 7-3
Level 1
Level 2
Level 3
Level 4
Level 5
Default value
Camera control
Auto camera contrast
Adjust contrast
On
0
Camera controllable
Bilinx camera enabled
No cameras selected
All cameras selected for
Bilinx version
Sequences
List Fullscreen monitor A
List Fullscreen monitor B
Dwell time monitor A
Dwell time monitor B
All cameras connected
All cameras connected
5 seconds
5 seconds
Configure Monitors
Display titles monitor A
Display titles monitor B
Display time / date monitor A
Display time / date monitor B
Display motion
On
On
On
On
Off
Status position
Bottom; 0
White; clear
Black
No
Text intensity
Cameo border intensity
Exit menu on alarms
Menu time-out
On
ATM/POS
Position
Top left
Duration
3 seconds
White; clear
Small
Text intensity
Font size
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Menu default values
EN | 7-4
Level 1
Level 2
Level 3
Level 4
Level 5
Default value
English
System Settings
Language
Recording Setup
Record mode
Continuous
None
Overwrite protection
Pre-event time
10 sec.
Disk Full Alarm Setup
Disk Full warning
Disk Full alarm
Output relay
Beeper
95%
1 min.
None
Disable
Playback Setup
Event Setup
List of (camera, block after)
No block
Alarm dwell time
Trigger dwell time
Input Setup
5 seconds
5 seconds
Output relay
Beeper
Relay 1
Enable
Display monitor A
Camera pre-positions
Camera pre-positions
None/PP01
None/PP01
Display monitor B
Input name
INPUT 01 ... INPUT 16
Auto-protect
Input 1 to 4
None
Protected before event
5 minutes
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Menu default values
EN | 7-5
Level 1
Level 2
Level 3
Level 4
Level 5
Default value
10 minutes
Protected after event
Max. auto-protected
On max. auto-protect
25% of disk
Warning only
Motion Setup
Output relay
Beeper
None
Disable
Video loss Setup
Display monitor A
Display monitor B
Output relay
Yes
No
Relay 2
Enable
Beeper
History log setup
Log alarms
Yes
Yes
Yes
Yes
Yes
Log motions
Log video loss
Log errors
Log network
Connectivity
Keyboard access
Keyboard 1
Keyboard 2
Keyboard 3
Keyboard 4
Both
Both
Both
Both
Network setup
DHCP
Yes
Discovery
DVR name
Enabled
DIVAR
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Menu default values
EN | 7-6
Level 1
Level 2
Level 3
Level 4
Level 5
Default value
0. 0. 0. 0
80
Default gateway
HTTP port
Bandwidth limit
100 MBPS
Network access
IP Range
List of IP addresses
User name
0. 0. 0. 0 -
255.255.255.255
List of users
ADMINISTRATOR,
USER2...6
User rights
Playback
User password
No password
Expand system
Com port
DVR ID
1
1
First camera number
Connect to
Baudrate
Parity
CCL
9600
None
8
Bits
Stopbits
RTS/CTS
1
On
Input and Output
contacts
Inputs
N/O
N/O
Outputs
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Menu default values
EN | 7-7
Level 1
Profiles
Level 2
Level 3
Level 4
Level 5
Default value
Profile manager
Camera pre-position on profile change
Event handling
Camera pre-position
None
1
System behavior
Select profile
Inputs enable
Enabled for connected
cameras
Inputs alarm
Enabled for connected
cameras
Motion enable
Motion alarm
Disable all
Disable all
Video loss enable
Enabled for connected
cameras
Auto acknowledge alarms
Yes
Output handling
Recording setup
Select profile
Relay enable
Beeper
1
Relays 1 and 2 enabled
Enable
Normal
Input
List all cameras, quality, IPS Medium, 1IPS
Cameras not in alarm, IPS
Recording duration
No change
30 seconds
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Menu default values
EN | 7-8
Level 1
Level 2
Level 3
Level 4
Motion
Level 5
Default value
Cameras not in alarm IPS
Recording duration
No change
15 seconds
Access restrictions
Select profile
Local playback password
User 2
1
Disable
Access
Access
Access
Access
Access
User 3
User 4
User 5
User 6
Copy system behavior
Copy from
Copy to
None
None
No
Advanced
menus
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Technical specifications
EN | 8-1
CHAPTER 8
Technical specifications
The following pages give the technical specifications of the unit.
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Technical specifications
EN | 8-2
overvoltage protection 40V,
max. cable length 1.5km
Electrical
Bilinx:
Bilinx-enabled controllable cameras via BNC camera
connectors (Divar Bilinx version only).
Voltage and Power
All models
100-240 VAC; 0.7-0.3A, 50/60Hz
Connectors
Video inputs:
Ethernet:
Video
6, 9 or 16 looping BNC, auto-terminating
RJ45 shielded, 10/100 BaseT according IEEE802.3
BNC (2), MON-A multiscreen, MON-B spot/alarm
Screw terminal input
Video standard:
Resolution:
AGC:
PAL/NTSC auto-detect
720 x 576 PAL - 720 x 484 NTSC
Monitors:
Automatic adjustment or manual adjustment of gain for
each video input
Alarm connectors:
Bi-Phase:
Screw terminal output
Digital Zoom:
Compression:
Inputs:
2 or 4 times
WAVELET
RS232:
DB9 male
Keyboard input:
Keyboard output:
SCSI:
RJ11 (6-pin)
composite video 0.5-2Vpp, 75 ohm, automatic
termination
RJ11 (4-pin), conform RS485, 30 units max.
HD 50-pin, max. 6 connected ultra SCSI devices,
20Mbytes/sec
Outputs:
1Vpp, 75 ohm, sync 0.3 V 10%
Alarm Handling:
Inputs:
Storage
Hard Disks:
16 configurable NO/NC
80GB -160GB - 320GB - 600GB
max. input voltage 40 VDC
Expandable via SCSI-2 HD50-pin, up to 6 external
storage arrays (17TB max.): type DVAD or DVAS.
Outputs:
4 relay outputs, configurable NO/NC
max. rated 30 VAC - 40 VDC - 0.5A continuous -10VA
File sizes:
High quality: 40Kb
Medium quality: 24Kb
Standard quality: 16Kb
Control
RS232:
Output signals according EIA/TIA-232-F
max. input voltage 25V
Record Rate (IPS):
NTSC: 60 total, configurable per camera: 30, 15, 10,
7.5, 6, 5, 4, 3, 2, 1, ½, 1/5, 1/10, 0, Never
Keyboard input:
Conform RS485, max. signal voltage 12V,
supply 11V-12.6V at max. 400mA
Conform RS485, max. signal voltage 12V
Impedance 128 ohm, max.
PAL: 50 total, configurable per camera: 25, 12.5, 8, 6,
5, 4, 3, 2, 1, ½, 1/5, 1/10, 0, Never
Recording Resolution:
720 x 288 PAL - 720 x 242 NTSC
Keyboard output:
Bi-Phase:
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Technical specifications
EN | 8-3
DVD writer
Electromagnetic Compatibility
Write speeds:
DVD+R / DVD+RW: 4x (or higher)
CD-R: 40x (or higher)
EMC requirements:
USA:FCC Part 15, Class B
EU: EMC directive 89/336/EEC
Immunity:EN50130-4
CD-RW: 24x (or higher)
1MB/sec. approx.
Divar write speed:
Emission:EN55022 Class B
Harmonics:EN61000-3-2
Display Modes:
Monitor A:
Voltage fluctuations:EN61000-3-3
USA:UL6500 2nd edition
EU:CE, EN60950: 2000
Full, full sequence, quad, quad sequence, multiscreen,
alarm call-up (live and playback)
Safety:
Monitor B:
Full, full sequence and alarm call-up
Canada:CAN/CSA - E60065-00
Recording Modes:
Linear, Continuous, Continuous with conditional overwrite.
Accessories (Optional)
KBD-Digital
LTC 8557
DVAD
Intui-Key keyboard with joystick
Mechanical
Keyboard Extension Kit
LP Storage Array
Dimensions:
Weight:
442 x 315 x 66 mm / 17.4 x 12.4 x 2.6 inch
approx. 7.5 kg / 16.5 lbs
DVAS
RAID Storage Array
Video manager
LTC 2605/91
LTC 8782
LTC 2604
DVRXEAP01
DVRSEAP02
DVRXEDVD1
Rack Mount Kit (Included): For mounting one unit in an EIA 19-inch rack.
Bi-phase code translaters
Keyboard port expander
ATM/POS bridge
Environmental
ATM/POS software license
External CD/DVD writer
Temperature:
Operating (version without DVD writer):
+0°C to +45°C (+32°F to +113°F)
Operating (version with DVD writer):
+5°C to +40°C (+41°F to +104°F)
Storage: -25°C to +70°C (-13°F to +158°F)
Operating: <93% non-condensing
Storage: <95% non-condensing
Relative humidity:
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Divar | Installation Manual | Technical specifications
EN | 8-4
Bosch Security Systems
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Bosch Sicherheitssysteme GmbH
Ludwig-Bölkow-Allee
Bosch Security Systems B.V.
P.O. Box 80002
85521 Ottobrunn
5600 JB Eindhoven
Germany
The Netherlands
© 2005 Bosch Security Systems B.V.
Subject to change. Printed in Portugal.
Download from Www.Somanuals.com. All Manuals Search And Download.
|