™
40 AMP SMART FULLY AUTOMATIC BATTERY CHARGER
INSTRUCTION MANUAL
Catalog Number BC40EB
Thank you for choosing Black & Decker!
Go to www.BlackandDecker.com/NewOwner
to register your new product
BEFORE RETURNING THIS PRODUCT
FOR ANY REASON PLEASE CALL
1-800-544-6986
BEFORE YOU CALL, HAVE THE CATALOG No, AND DATE CODE
AVAILABLE. IN MOST CASES, A BLACK & DECKER REPRESENTATIVE
CAN RESOLVE THE PROBLEM OVER THE PHONE. IF YOU HAVE A
SUGGESTION OR COMMENT, GIVE US A CALL. YOUR FEEDBACK IS
VITAL TO BLACK & DECKER.
SAVE THIS MANUAL FOR FUTURE REFERENCE.
Cat. # BC40EB
May ’07
Form # 90516444
Copyright © 2007 Black & Decker
Printed in China
Download from Www.Somanuals.com. All Manuals Search And Download.
SAFETY GUIDELINES / DEFINITIONS
DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
CAUTION: Used without the safety alert symbol indicates potentially hazardous situation which, if not avoided, may result in
property damage.
RISK OF UNSAFE OPERATION. When using tools or equipment, basic safety precautions should always be followed to
reduce the risk of personal injury. Improper operation, maintenance or modification of tools or equipment could result in
serious injury and property damage. There are certain applications for which tools and equipment are designed. Black &
Decker strongly recommends that this product NOT be modified and/or used for any application other than for which it
was designed. Read and understand all warnings and operating instructions before using any tool or equipment.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: This product or its power cord contains lead, a chemical known to the State of California to
cause cancer and birth defect or other reproductive harm. Wash hands after handling.
WARNING: BURST HAZARD: Do not use the unit for charging dry-cell batteries that are commonly used with
home appliances. These batteries may burst and cause injury to persons and damage property. Use the unit for
charging/boosting a LEAD-ACID battery only. It is not intended to supply power to a low-voltage electrical system other
than in a starter-motor application. NEVER EQUALIZE A GEL OR AGM BATTERY, these may burst and cause
SERIOUS INJURY and property damage.
WARNING: SHOCK HAZARD:
• If an extension cord is used, make sure that:
a) the pins of extension cord are the same number, size and shape as those in the charger,
b) the extension cord is properly wired and in good electrical condition,
c) the wire size is large enough for the AC rating of the charger as indicated in the table on page 1.
• Do not operate unit with damaged cord or plug; or if the unit has received a sharp blow, been dropped, or
otherwise damaged in any way. Do not disassemble the unit; take it to a qualified service technician when service
or repair is required. Incorrect reassembly may result in a risk of electric shock or fire, and will void warranty.
• Use of an attachment not supplied, recommended or sold by manufacturer specifically for use with this unit
may result in a risk of electrical shock and injury to persons.
• NEVER submerge this unit in water; do not expose it to rain, snow or use when wet.
• To reduce risk of electric shock, disconnect the unit from any power source before attempting maintenance or
cleaning. Turning off controls without disconnecting will not reduce this risk.
WARNING: RISK OF EXPLOSIVE GASES
• Working in the vicinity of a lead acid battery is dangerous. Batteries generate explosive gases during normal
battery operation. For this reason, it is of the utmost importance that each time before using the charger you
read this manual and follow instructions exactly.
• To reduce the risk of battery explosion, follow these instructions and those published by the battery
manufacturer and manufacturer of any equipment you intend to use in the vicinity of the battery. Review
cautionary markings on these products and on the engine.
• This equipment employs parts (switches, relays, etc.) that produce arcs or sparks. Therefore, if used in a
garage or enclosed area, the unit MUST be placed not less than 18 inches above the floor.
• THIS UNIT IS NOT FOR USE BY CHILDREN AND SHOULD ONLY BE OPERATED BY ADULTS.
CAUTION: TO REDUCE THE RISK OF INJURY OR PROPERTY DAMAGE:
• Pull cord by plug rather than cord when disconnecting the 120V AC Charging Adapter from the unit.
• NEVER ATTEMPT TO JUMP-START OR CHARGE A FROZEN BATTERY.
• To recharge this unit, use only the supplied AC Charging Adapter.
• Vehicles that have on-board computerized systems may be damaged if vehicle battery is jump-started. Before
jump-starting, read the vehicle’s owner’s manual to confirm that external-starting assistance is suitable.
• When working with lead acid batteries, always make sure immediate assistance is available in case of accident
or emergency.
• Always have protective eyewear when using this product: contact with battery acid may cause blindness
2
Download from Www.Somanuals.com. All Manuals Search And Download.
and/or severe burns. Be aware of first aid procedures in case of accidental contact with battery acid.
• Have plenty of fresh water and soap nearby in case battery acid contacts skin.
• If battery acid contacts skin or clothing, wash immediately with soap and water for at least 10 minutes and get
medical attention immediately.
• Never smoke or allow a spark or flame in vicinity of vehicle battery, engine or charger.
• Remove personal metal items such as rings, bracelets, necklaces and watches when working with a lead acid
battery. A lead acid battery can produce a short circuit current high enough to weld a ring, or the like of a metal,
causing a severe burn.
• Never allow battery acid to come in contact with this unit.
• Do not operate this unit in a closed area or restrict ventilation in any way.
• FIRST AID – SKIN: If battery acid comes in contact with skin, rinse immediately with water, then wash
thoroughly with soap and water. If redness, pain, or irritation occurs, seek immediate medical attention.
EYES: If battery acid comes in contact with eyes, flush eyes immediately, for a minimum of 15 minutes and
seek immediate medical attention.
• GROUNDING AND AC POWER CORD CONNECTION INSTRUCTIONS – Charger should be grounded to reduce
risk of electric shock. Charger is equipped with an electric cord having an equipment-grounding conductor and
a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in
accordance with all local codes and ordinances.
DANGER – Never alter AC cord or plug provided – if it will not fit outlet, have proper outlet installed by a
qualified electrician. Improper connection can result in a risk of an electric shock.
Preparing to Charge
1. Determine voltage of battery to be charged by referring to the vehicle manual.
2. it is necessary to remove battery from vehicle to charge, or to clean terminals, always remove grounded
terminal from battery first. Make sure all accessories in the vehicle are off, so as not to cause an arc.
3. Clean battery terminals. Do not allow corrosion to come in contact with eyes.
4. Add distilled water in each cell until battery acid reaches level specified by battery manufacturer. This helps
purge excessive gas from cells. Do not overfill. For a battery without cell caps (maintenance free), carefully
follow manufacturer's charging instructions.
5. Study all battery manufacturer’s specific precautions, such as removing or not removing cell caps while
charging, and recommended rates of charge.
6. Remove battery completely from boat/airplane or any confined area before charging.
7. Make sure the initial charging rate does not exceed battery manufacturer’s requirement.
Charger Location
1. Locate charger as far away from battery as cables permit.
2. NEVER place charger directly above battery being charged; gases from battery will corrode and damage charger.
3. NEVER allow battery acid to drip on charger when reading gravity or filling battery.
4. NEVER operate charger in a closed-in area or restrict ventilation in any way.
5. Marine batteries must be removed and charged on shore.
6. Do not set a battery on top of charger.
DC Connection Precautions
1. Connect and disconnect DC output clamps only after removing AC cord from electric outlet.
2. Never allow clamps to touch each other.
3. Attach clamps to battery and chassis as indicated in “Battery Installed in Vehicle” steps 5 and 6, and in
“Battery Outside of Vehicle” steps 2, 4 and 5.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Follow these steps when the battery is installed in a vehicle. A spark near the battery may cause an explosion.
CAUTION: TO REDUCE RISK OF A SPARK NEAR THE BATTERY:
1. Position AC and DC cords away from hood, door, or moving engine parts.
2. Stay clear of fan blades, belts, pulleys, and other parts that can cause injury to persons.
3. Check polarity of battery posts. POSITIVE (POS, P, +) battery post usually has larger diameter than NEGATIVE
(NEG, N, –) post.
4. Determine which post of battery is grounded (connected) to the chassis. If negative post is grounded to
chassis (as in most vehicles), see 5. If positive post is grounded to the chassis, see 6.
5. For negative-grounded vehicle, connect POSITIVE (RED) clamp from battery charger to POSITIVE (POS, P,
+) ungrounded post of battery. Connect NEGATIVE (BLACK) clamp to vehicle chassis or engine block away from
battery. Do not connect clip to carburetor, fuel lines, or sheet-metal body parts. Connect to heavy gauge metal
part of the frame or engine block.
6. For positive-grounded vehicle, connect NEGATIVE (BLACK) clamp from battery charger to NEGATIVE (NEG, N,
–) ungrounded post of battery. Connect POSITIVE (RED) clamp to vehicle chassis or engine block away from
battery. Do not connect clip to carburetor, fuel lines or sheet-metal body parts. Connect to a heavy gauge metal part
of the frame or engine block.
7. When disconnecting charger, disconnect AC cord, remove clamp from vehicle chassis, and then remove
clamp from battery terminal.
8. Do not charge the battery while the engine is operating.
9. See operating instructions for length of charge information.
Follow these steps when the battery has been removed from a vehicle. A spark near the battery may cause an explosion.
1. Check polarity of battery posts. Positive post (marked POS,P, +) usually has a larger diameter than the
Negative battery post (marked NEG, N, –).
2. Attach a 24-inch (minimum length) 6 AWG insulated battery cable to the Negative battery post (marked NEG, N, –).
3. Connect the Positive (RED) battery clamp to the Positive battery post (marked POS, P, + or red).
4. Stand as far back from the battery as possible, and do not face battery when making final connection.
5. Carefully connect the NEGATIVE (BLACK) charger clamp to the free end of the battery cable connected to the
negative terminal.
6. Set the charge rate to appropriate setting according to battery size.
7. When disconnecting charger, always do so in reverse sequence of connecting procedure and break first
connection while as far away from battery as practical.
Note: A marine (boat) battery must be removed and charged on shore. To charge it on board requires
equipment specially designed for marine use. This unit is NOT designed for such use.
• Check unit periodically for wear and tear. Take to a qualified technician for replacement of worn or defective
parts immediately.
• Read and Understand This Instruction Manual Before Using This Unit.
SAVE THESE INSTRUCTIONS
THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS FOR THE 40 AMP SMART™ BATTERY
CHARGER MODEL BC40EB.
WARNING: TO REDUCE THE RISK OF INJURY:
• Follow these instructions and those published by the battery manufacturer and manufacturer of any equipment you
intend to use with this unit. Review cautionary markings on these products and on engine.
INTRODUCTION
Thank you for selecting the Black & Decker® 40 Amp Smart™ Battery Charger. With proper care and use, it will give
you years of dependable service. This battery charger has a high charge rate of up to 40 amps, and low charge rate
of 4 amps and 110 amps of engine starting power.
Smart™ Battery Chargers feature 3-stage, high-efficiency charging technology, built-in microprocessor control
that ensures fast, safe and complete charging of serviceable batteries.
S
tage One — Rapid Start Charge at 40 amps delivers maximum charging amperage to “wake up” any serviceable
12 volt battery and allows for quick engine starting. When battery reaches a maximum safe predetermined voltage,
the charger will automatically signal a "beep" and move into Stage 2 of the charging process.
Stage Two — Absorption Charge maintains the maximum possible charge at a constant, safe, predetermined
voltage. During this phase, the charging voltage remains constant, while the actual charging current is reduced
4
Download from Www.Somanuals.com. All Manuals Search And Download.
to allow for the maximum proper internal chemical energy transfer. At the end of Stage 2, the charger will
automatically move into Stage 3 charge mode.
Stage Three — Top-Off Charge voltage is
STAGE ONE
automatically maintained and reduced to a
BEEP
BEEP
predetermined level while current is adjusted
Charge Curve
for a safe, effective battery charge. At the end
STAGE TWO
of Stage 3, the unit will BEEP signaling the
completion of the charging cycle.
The Automatic Float Charge feature is ideal
for maintaining a battery. It automatically
tops off battery as needed, keeping it fully
charged all the time.
STAGE THREE
OFF BEEP
CHARGING
COMPLETE
FEATURES
• This unit has four charge rate settings, accessed by the 4/10/20/40 AMP button:
a) 4 amps: smaller batteries, such as in lawn mowers, snowmobiles, motorcycles, etc.
b) 10 amps: mid-sized batteries, such as in small cars
c) 20 amps: automobiles and light trucks
d) 40 amps: utility vehicles
• 110 amp engine start
• Automatic Temperature Compensation
• Battery type selection
• Digital diagnostics
• Alternator voltage and battery voltage check
• Digital display shows charge rate, operating mode, fault codes and FUL when charged
• 1-minute engine start
• 3-stage high-frequency switch mode automatic rapid charging
• Spark resistant reverse polarity and short circuit protection for user
• Built-in battery reconditioning (desulfate)
• Lightweight, high-efficiency design
• Internal short circuit protection
• Cables and clamps self-stored
• Reverse polarity indication
• Microprocessor control (Digital Smart Control)/High frequency power
• Compensates for low AC from extension cord use
• Equalization function
Controls and Indicators
CONTROL PANEL
DIGITAL READOUT CIRCULATING
PATTERN
Function Buttons (from left to right):
Battery Type (Step 1) allows the user to select Wet, Gel or AGM type of battery for efficient and safe charge.
Most automotive batteries are Wet batteries. Refer to the battery manufacturer’s specifications for battery type.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
4/10/20/40A AMP (Charge Rate Selector) (Step 2) allows the user to select the charge rate based on
battery size. This selection and the actual battery charge rate are monitored by the microprocessor. The charger
will stop charging if the rate is too fast or too slow for the battery size or condition.
110 AMP Engine Start places the charger in an engine start sequence. This button will not be activated unless
the charger is in the 40 amp charge mode; set the 4/10/20/40 amp button to 40 amps first to activate this button.
Battery Recondition is an automatic mode that, once started, continues for 24 hours and then stops. A series
of electrical pulses breaks the crystalline form of lead sulfate to return these chemicals into useful battery
electrolytes. More than 24 hours may be needed to restore. Periodic reconditioning is recommended to
maintain a battery's optimum performance. However, if 5 cycles does not improve battery performance,
discontinue and recycle the battery.
Battery Voltage (Alternator Voltage Check) is a quick check that measures the battery voltage. This check
is repeated at various electrical load levels and the tests allow the user to determine if the alternator can keep
up with the loads.
INDICATOR:
Large (.375”) 3-Character Digital Display in the upper left of the control panel indicates the various
conditions and/or status codes:
Status Codes are described in the following chart and on the back of charger.
AC POWER INDICATOR - When connected to an AC outlet, digital display shows circulating pattern to
indicate power is on. Disconnect charger after use.
FAULT CODES
INTERNAL SHORTED CELL BATTERY - Cannot be charged. Have battery checked by certified auto service center.
EXCESSIVE LOAD ON BATTERY WHILE CHARGING - Check load.
F01
BAD BATTERY CONNECTION - Check battery connection.
BATTERY VOLTAGE TOO LOW TO ACCEPT CHARGE - Have battery checked by certified auto service center.
F02
INTERNAL OPEN CELL - Have battery checked by certified auto service center.
SULFATED CONDITION - Battery needs to be reconditioned. See manual.
F03
OVERTIME CONDITION - Battery will not accept a charge after 18 hours of continuous charging. Battery may have
internal damage. Have battery checked by certified auto center.
F04
BATTERY CHARGE RATE IS SET TOO LOW - Set charger to higher charge rate. See manual.
OVERHEATED CONDITION - Disconnect charger and allow to cool for 30 min., check for ample ventilation.
F05
F06
F07
REVERSE POLARITY
ALTERNATOR OUTPUT IS OUT OF TYPICAL OPERATION RANGE
OPERATION CODES
BATTERY RECONDITIONING - (The letters DES will display for the first 3 seconds.)
ALTERNATOR VOLTAGE CHECK
CHARGER STANDBY
BATTERY FULLY CHARGED
000
FUL
CONTROL PANEL LED INDICATORS:
WET — lights when battery type selector is on WET battery type
GEL — lights when battery type selector is on GEL battery type
AGM — lights when battery type selector is on AGM battery type.
Float Charge — lights when automatic charge monitoring is active. This feature allows a battery to maintain
its charge over long periods of non-use. If there is any loss of power to the charger once power is restored,
charger will automatically return to the default settings. Battery selector type would be “gel”.
Battery Voltage — lights when battery voltage is displayed.
Alternator Good — lights when load or no load checks show the alternator is keeping up with the electrical load.
Equalize — a recessed button used to start the equalize process.
OPERATING INSTRUCTIONS
Ensure that all installation and operating instructions and safety precautions are understood and carefully
followed by anyone installing or using the charger. Follow the steps outlined in the “Important Safety
Instructions” section of this manual.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Charge Rate Selection
After charger clamps are correctly connected, plug the charger into a 120 volt AC outlet and the charger will
show “000” on the Digital Display, indicating power has been applied. Select the proper charge current rate
based on battery size. Press the 4/10/20/40 AMP button and the charger will begin charging at 4 amps.
Pressing the 4/10/20/40 AMP button again will advance the charge rate to 10 amps, again to 20 amps, and
again to 40 amps. Pressing the switch again will turn OFF the charger output and the display will show “000”.
Note: The only time the selected charge rate does not display at the full selected rate is when the battery is
nearly full and charging at either step two or three. The display will show a reduced charge rate. To return to
4A, press the 4/10/20/40 amp button. When the battery is fully charged, “FUL” shows on the Digital Display.
WARNING: If Digital Display shows “F02”, the connection to the battery terminals is bad. Follow the steps
outlined in “Important Safety Instructions” at the front of this manual to disconnect, clean battery terminals,
then reconnect.
If Digital Display shows “F06”, the Red (Positive) and Black (Negative) clamps are incorrectly connected to
battery terminals. Follow the steps outlined in “Important Safety Instructions” at the front of this manual to
disconnect, then reconnect in correct polarity.
Charging the Battery
1. Press Battery Type selector until desired battery type LED lights.
Note: The default selection is “GEL” type battery.
2. Press 4/10/20/40 AMP button to begin charging at the 4 amp rate; the unit sounds a beep and displays
charging current. The charger starts charging at 4 amp rate automatically if 4/10/20/40 AMP button is not
pressed within 3 minutes after applying AC power.
If the Display on the charger varies between “F03” and the amp rate, the battery is sulfated and the charger is
trying to give it some charge. If after approximately 3 hours the display just shows “F03”, then the battery will
not charge.
Charger occasionally sounds a beep and displays “0.0” during self-test or charging stage changes.
3. Pressing the 4/10/20/40 AMP button again advances charging rate to 10 amps. Pressing once more
advances charging rate to 20 amps, and again to 40 amps. (Pressing the button again will turn OFF the charger
output and the Display will show “000”.) This selection and actual battery charge rate are monitored by the
microprocessor, and the unit will stop charging if the selected rate is too fast or too slow for battery size or
condition.
As the battery nears full charge capacity, the unit’s output will automatically drop to a lower charge rate.
Pressing the 4/10/20/40 AMP button repeatedly advances to standby mode; the unit sounds a beep, displays
“000” and stops charging.
4. The battery charger displays the charge current. To view the battery voltage, press BATTERY VOLTAGE
button. The charger will sound a beep and display the battery voltage. Press the BATTERY VOLTAGE button
again to return to displaying the charge current.
5. The display shows “FUL” when the battery is fully charged.
6. Follow the steps outlined in “Important Safety Instructions” at the front of this manual to disconnect.
Automatic Float Charging
Automatic Float Charging is ideal for maintaining a fully charged battery.
1. Keep the AC power and battery connected after battery is fully charged.
2. The charger monitors the battery and tops it off as needed.
3. The Float Charge indicator lights and the display shows charge current when topping off the battery and
returns to “FUL” when completed.
4. To view battery voltage, press the Battery Voltage button.
Note: Charging can be terminated by pressing the charge rate selector button at any time when unit is
charging. After AC power interruption, charging restarts at 4 amp rate automatically and the battery type will
default to “GEL”.
WARNING: If battery size is not known, charge at the 4 amp rate. DO NOT overcharge batteries.
Equalizing
Equalizing is the process by which the fluid in each of a battery’s cells is equalized. This process occurs after
charging is complete.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNING: BURST HAZARD:
• NEVER EQUALIZE A GEL OR AGM BATTERY, these may burst and cause SERIOUS INJURY and property
damage.
• Remove or disconnect the vehicle’s battery when equalizing.
The frequency which the equalization process needs to be run depends on the use of the battery. The more the
battery is used, the more undercharged it becomes; thus the more frequently the battery should be equalized.
1. Do not use this mode on sealed or valve regulated batteries. This mode is only meant for wet
(unsealed/vented) batteries.
2. Make sure there are no flammable sources near the recharging sight.
3. Wear safety glasses, gloves and protective clothing.
4. Remove battery from vehicle. Make sure that the battery has good ventilation. The process causes the
release of hydrogen and oxygen. An accumulation of these gases presents a real danger of explosion.
5. Open the battery cap, if removable.
6. Fill the battery with distilled water according to the manufacturer’s instructions. Since batteries may rapidly
bubble while being charged, remember to refill (only with distilled water) after the equalization process is
complete and the voltage is back to normal.
7. Follow the steps in the “Charging the Battery” section on page 7 of this manual.
8. Push the Battery Type Selector Switch until “WET” is displayed. (This mode will only work if a WET battery
is selected.)
9. Choose the correct charge rate and start charging. You can check the battery voltage by pushing the Battery
Voltage button. This will trigger the Battery Voltage indicator.
10. Push the Equalize button at any time and the battery will automatically begin to equalize in 4 amp limited
current. Note that in order to push the recessed button you will need a small pin or ballpoint pen.
11. Every hour, the temperature should be checked by touching the battery. If the battery is hot to the touch,
stop the charging and allow the battery to cool.
12. The voltage rises, but does not go over 15.3v to 16.2v (2.55-2.7v per cell) depending on ambient
temperature, it will automatically adjust.
13. The “WET” LED flashes while the charger is in equalize mode.
14. The digital readout will show “FUL” when the equalization process is complete.
Engine Start
The Engine Start function can supply 110 amps for engine starting.
1. Set the 4/10/20/40 AMPS button to 40 amp mode and immediately press the 110A button switch to activate
the Engine Start mode.
2. The digital display will countdown from “999” to “000.”
3. When the “000” count is reached and begins flashing on the Display, the vehicle is ready to start.
4. Crank the engine using manufacturer’s guidelines, typically in 3 to 5 second bursts. The high current engine
starting function requires a resting/cooling period between tries. The charger will switch back to regular
charge mode after 5 seconds and will not allow operation in this mode for 4 minutes. Wait 4 to 5 minutes
before a second attempt at starting the engine, if needed.
5. During the rest period, the battery is charging at 4 amps. After engine starts, follow the steps outlined in
“Important Safety Instructions” at the front of this manual to disconnect.
Recondition Mode
Whenever a lead-acid battery begins to discharge, lead sulfate, an insulator, begins to build up on the battery’s
internal plates. This reduces the ability of the battery to hold a full charge. When that battery has an immediate
charge, most of the lead sulfate is dissolved and the plates are free of this insulation. If a battery remains in a
discharged condition over a longer period of time, the lead sulfate changes to a hard crystalline form, making a
full charge difficult to achieve. Reconditioning may “save” a sulfated battery.
BATTERY RECONDITION MODE should only be used with 10 Amp Hour (Ah) or larger capacity lead-acid
batteries. Charge the battery to be treated for 20 minutes, before using RECONDITION Mode. Observe the
Digital Display for any codes. This initial charge will check the battery for shorted cells (F01), open cells (F03)
or battery too low to accept a charge (F02), and to ensure the battery can take a charge. If code (F03) is
displayed, change to the BATTERY RECONDITION MODE.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Remove or disconnect the vehicle’s battery when reconditioning.
1. Make sure the charger is in initiation state with a circulating pattern on the display or in charge OFF mode
with “000” on the display. If not, press 4/10/20/40 AMP button repeatedly until “000” shows on the display.
2. Press the Battery Recondition button to start the process.
3. DES appears on the display for 3 seconds, then it changes to three horizontal moving bars.
4. The process takes 24 hours and stops automatically. The display shows “000” when complete.
Alternator Check
Part 1
No Load (Turn OFF all vehicle’s accessories): The battery must be fully charged before testing the alternator.
Run the engine long enough to achieve normal idle speed and verify there is a no-load voltage.
1. Press Alternator Check to start the check.
2. Alternator Good LED will light to indicate the alternator is good, or F07 will display to indicate the alternator
is out of typical voltage range.
3. Press Alternator Check again to stop the test.
Part 2
Under Load (Accessories ON): Next, load the alternator by turning on as many accessories as possible (except
for A/C and DEFROST)
1. Press Alternator Check to start the check.
2. Alternator Good LED will light to indicate the alternator is good, or F07 will display to indicate the alternator
is out of typical voltage range.
3. Press Alternator Check again to stop the test.
If the first alternator check indicates a good alternator and the second indicates the alternator is not good, the
problem could stem from: loose fan belts, an intermittent diode failure or possibly bad connections between the
battery and alternator and/or ground.
Notes: BATTERY VOLTAGE button is disabled in Alternator Check mode.
F07 may display because someone has added a number of accessory loads on the charging system, thereby
increasing current demand from the alternator. MAKE SURE THAT THE ALTERNATOR IS RATED TO SUPPORT
THE APPLICATION.
This check may not be accurate for every make, manufacturer and model of vehicle. Check only 12 volt systems.
APPROXIMATE CHARGING TIMES
The 40 Amp Smart™ Battery Charger will automatically adjust the charge rate as the battery becomes
charged, and stop when the battery is fully charged. Deep cycle batteries may require longer charging time.
For estimates of the time it takes to charge a battery, refer to the following table.
Percent of charge
in battery
75%
50%
25%
0%
at 4 amp rate
at 10 amp rate
at 20 amp rate
at 40 amp rate
3.5 HRS
1.4 HRS
1.0 HRS
1.0 HRS
7.0 HRS
2.8 HRS
1.5 HRS
1.2 HRS
10.5 HRS
4.2 HRS
2.1 HRS
1.7 HRS
NR*
5.5 HRS
2.8 HRS
2.2 HRS
*NR = Not recommended at 4 amps — use a higher charge rate.
The times shown in the table above are approximate and refer to a 50 Ah automotive battery. For example, a 50
Ah (12 volt) battery is discharged (50%). How long should it be charged at the 10 amp rate? See the chart
above under “50%” and “at 10 amp rate.”
In most cases, battery charging times will vary depending on the size, age and condition of the battery. Smaller
batteries should be charged at a lower rate (4 amps) and an extra hour added to charge time.
TROUBLESHOOTING
Display Indications/Common Problems/Possible Solutions
No Functions
• Check and make sure the charger is plugged into a live 110/120 volt AC outlet.
• Follow the steps outlined in the Operating Instructions section.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
F01 — Internal Shorted Cell Battery
If the battery being charged has an internal shorted cell, the F01 will show. We recommend taking your battery
to a certified automotive service center for evaluation.
F02 — Bad Battery Connection or Battery Voltage Too Low to Accept Charge
When F02 appears, the most common cause is poor connection to battery.
• Follow the steps outlined in “Important Safety Instructions” at the front of this manual to disconnect AC cord
and clamps, clean battery terminal and reconnect.
• If the situation persists, we recommend taking your battery to a certified automotive service center for evaluation.
F03 — Sulfate or Unchargeable Battery
Appears when the battery is highly sulfated and cannot accept normal charge current.
• Follow the steps in “Recondition Mode” to recondition the battery.
• Follow the steps in “Equalizing” to equalize the battery.
• If the situation persists after reconditioning and equalizing, we recommend taking your battery to a certified
automotive service center for evaluation.
F04 — Overtime Condition
Appears when charging time exceeds 18 hours. You may be using a charge current rate too low for a large
battery. Select higher charge rate to charge the battery.
F05 — Overheated Condition
The ventilation grill that prevents the air from flowing in and out of the charger may be blocked.
• Follow the steps outlined in “Important Safety Instructions” at the front of this manual to disconnect AC cord
and clamps, allow the unit to cool for 30 minutes and reconnect.
• Make sure there is ample ventilation before resuming operation.
F06 — Reverse Polarity
The connections to the battery’s positive and negative terminals are incorrect. Follow the steps outlined in
“Important Safety Instructions” at the front of this manual to disconnect AC cord and clamps and reconnect to
battery with correct polarity.
F07 — Alternator Voltage
Alternator output voltage is out of typical operation range.
Charging a Very Cold Battery
If the battery to be charged is very cold (in temperatures below freezing — 0°C/ 32°F), it cannot accept a high
rate of charge. The initial charge rate will be low. The charge rate will increase as the battery warms. Never
attempt to charge a frozen battery.
CARE AND MAINTENANCE
With proper care and minimal maintenance, the 40 Amp Smart™ Battery Charger will provide years of
dependable service. For maximum performance, manufacturer recommends:
• After each use, clean the battery charger clamps — be sure to remove any battery fluid that will cause
corrosion of the clamps.
• Clean the outside case of the charger with a soft cloth and, if necessary, mild soap solution.
• Do not allow liquid to enter the charger. Do not operate when charger is wet.
• Keep the charger cords loosely coiled during storage to prevent damage to the cords.
WARNINGS:
• Do not use charger if cords or clamps have been damaged in any way — call Technical Support toll-free at
(800) 544-6986.
• There are no user-serviceable parts in this unit.
• Do not open the unit. In the event of malfunction, it must be returned to manufacturer for professional testing
and repair. Opening the unit will void the manufacturer’s warranty.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Accessories
Recommended accessories for use with your tool are available from your local dealer or authorized service
center. If you need assistance regarding accessories, please call: 1-800-544-6986.
WARNING: The use of any accessory not recommended for use with this tool could be hazardous
SERVICE INFORMATION
All Black & Decker Service Centers are staffed with trained personnel to provide customers with efficient and
reliable power tool service. Whether you need technical advice, repair, or genuine factory replacement parts,
contact the Black & Decker location nearest you. To find your local service location, refer to the yellow page
FULL FIVE-YEAR HOME USE WARRANTY
Black & Decker (U.S.) Inc. warrants this product for five years against any defects in material or workmanship.
The defective product will be replaced or repaired at no charge in either of two ways.
The first, which will result in exchanges only, is to return the product to the retailer from whom it was purchased
(provided that the store is a participating retailer). Returns should be made within the time period of the retailer’s
policy for exchanges (usually 30 to 90 days after the sale). Proof of purchase may be required. Please check with
the retailer for their specific return policy regarding returns that are beyond the time set for exchanges.
The second option is to take or send the product (prepaid) to a Black & Decker owned or authorized Service
Center for repair or replacement at our option. Proof of purchase may be required. Black & Decker owned and
authorized Service Centers are listed under "Tools-Electric" in the yellow pages of the phone directory and on
This warranty does not apply to accessories. This warranty gives you specific legal rights and you may have
other rights which vary from state to state or province to province. Should you have any questions, contact the
manager of your nearest Black & Decker Service Center. This product is not intended for commercial use.
FREE WARNING LABEL REPLACEMENT: If your warning labels become illegible or are missing, call 1-800-
544-6986 for a free replacement.
SPECIFICATIONS
Input:
120V AC 60Hz, 700 watts continuous
1500 watts engine start
Output:
12 volts DC, 4/10/20/40 amps continuous
110 amps engine start
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. This limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Imported by
See ‘Tools-Electric’
– Yellow Pages –
for Service & Sales
Black & Decker (U.S.) Inc.,
701 E. Joppa Rd.
Towson, MD 21286 U.S.A.
Vector Products, Inc
4140 SW 30th Ave.
Fort Lauderdale, FL 33312
11
Download from Www.Somanuals.com. All Manuals Search And Download.
|