T EC h S PECS
Cable Required —
Between hubs and remote units:
Software: Transparent to software flow control;
ACU1006VRA, ACU1006DVRA, ACUVREM, ACUWREM, ACU1006MRVA:
Flow control: Transparent to hardware and software flow control
(RTS, CTS, DTR, and DSR are all passed through across the link)
Synchronization — H/V or composite, TTL signal levels;
sync polarity is preserved
Category 5 solid unshielded or shielded twisted pair (UTP or
STP), wired to the TIA/EIA-568A or (preferred) -568B standard,
terminated with RJ-45 M connectors
Clamping Voltage — Up to 15 volts
Compatibility —
Video Bandwidth (to -3 dB) —
Video: VGA, SVGA, XGA, XGA-2, or RGsB (sync on green), although if
your system has monitor ID-bit requirements, you might need to
call Black Box for technical support;
ACU1006RA, ACU1012RA, ACU1006DRA, ACU1006SRA,
ACU1006DSRA, ACU1006VRA, ACU1006DVRA: 150 MHz per port;
ACUREM, ACUSREM, ACUVREM, ACUREMSW, ACU1006MRVA:
Intrinsic: 300 MHz;
Across 328 ft. (100 m) UTP: 95 MHz (with equalization)
Video Compensation —
With ACUMREM, ACUWREM, ACU1006MRA: For short- or
long-distance (user-selectable);
With all other remote units: 3-stage continuously variable
Video Coupling — DC
Video I/O Signal Levels — 0.7 volts peak to peak
User Controls —
ACU1006SRA, ACU1006DSRA:
(6) internal data-rate jumpers (1 for each port);
(6) internal flow-control jumper blocks (1 for each port);
ACUREM, ACUSREM, ACUVREM, ACUREMSW:
(2) front-mounted dials: Brightness and Focus;
(3) internal video-distance (cable-length) jumpers;
(1) internal 4-position DIP switch for various options;
ACUSREM:
Keyboard: IBM PC/AT or PS/2 compatible (PC/AT types require connector
adapter);
Mouse: IBM PS/2 compatible two-button, Microsoft® IntelliMouse®,
or Logitech® PS/2 compatible three-button
Compliance — CE Class B; FCC Part 15 Subpart B Class A, IC Class/classe A
Distance (Maximum) —
ACU1006RA, ACU1012RA, ACU1006DRA, ACU1006SRA,
ACU1006DSRA, ACU1006VRA, ACU1006DVRA:
16.4 ft. (5 m) from a local hub to the attached local equipment;
16.4 ft. (5 m) from each remote unit to the attached remote
equipment;
164 ft. (50 m) between a local hub and any Micro remote unit;
1000 ft. (304.8 m) between a local hub and any other
type of remote unit;
ACUREM, ACUSREM, ACUVREM, ACUWREM, ACUREMSW,
ACU1006MRA:
16.4 ft. (5 m) from the remote to the attached remote equipment;
1000 ft. (304.8 m) between a local hub and any other
type of remote unit;
(1) internal data-rate jumper;
(1) internal flow-control jumper block;
ACUMREM, ACU1006MRVA:
16.4 ft. (5 m) between the remote and the attached remote
equipment;
ACUMREM, ACUWREM:
(1) bottom-mounted 2-position DIP switch for video distance (cable
length) and keyboard-command recognition;
ACU1006MRA, ACU1006MRVA:
150 ft. (45.7 m) between a local hub and the micro remote unit
(6) internal 2-position DIP switches for video distance and keyboard-
command recognition, (1) for each local-to-remote link;
ACUVREM, ACUWREM only:
NOTE: With high-quality cables, it might be possible to run farther than
16.4 ft. (5 m) from the hub or a remote unit to attached equipment.
(1) internal microphone-amplification jumper;
ACU1006MRVA only:
(6) internal microphone-amplification jumpers, (1) for each
local-to-remote link
Mean Time Between Failure (MTBF) — 40,000 hours
Interface —
Between local hubs and remote units: Proprietary composite
of all supported types of computer I/O;
On local hubs to CPUs:
Resolution (Maximum) —
ACUREM, ACUSREM, ACUVREM, ACUREMSW:
1600 x 1280: 200 ft. (61 m);
1280 x 1024: 300 ft. (91.4 m);
1024 x 768: 1000 ft. (304.8 m);
ACUMREM, ACUWREM:
1280 x 1024: 150 ft. (45.7 m)
Serial Characteristics —
ACU1006SRA, ACU1006DSRA, ACUSREM:
Data rate: 9600 bps or 9.2 kbps, user selectable;
Data format: 8 data bits, no parity, 1 stop bit (fixed);
ACU1006VRA, ACU1006DVRA, ACUWREM:
Data rate: Up to 19.2 kbps;
Data format: 8 data bits, no parity, 1 stop bit (fixed);
ACUVREM, ACU1006MRVA:
Proprietary composite of VGA-compatible video and IBM
PS/2 compatible keyboard and mouse;
ACU1006SRA, ACU1006DSRA, ACU1006VRA only: TIA/EIA RS-232 (DCE);
ACU1006VRA, ACU1006DVRA only: Bidirectional 3.5-mm mini
stereo audio;
ACU1006DRA, ACU1006DSRA, ACU1006DVRA:
To local monitor: VGA;
To local keyboard and mouse: IBM PS/2 compatible;
Remote units: Depending on the type of unit, either separate
or proprietary composite VGA video and IBM PS/2 compatible
keyboard and mouse;
Data rate: Up to 19.2 kbps;
Data format: 8 data bits, no parity, 1 stop bit;
ACU1006RA, ACU1012RA, ACU1006DRA, ACU1006SRA, ACU1006DSRA,
ACUREM, ACUSREM, ACUMREM, ACUREMSW, ACU1006MRA:
Flow control:
ACUREM, ACUSREM, ACUVREM, ACUREMSW, ACU1006MRVA
only: TIA/EIA RS-232 (DTE);
ACUVREM, ACUWREM, ACU1006MRVA: 3.5-mm mini stereo audio
Hardware: RTS/CTS passed through or looped back, DTR/DSR
passed through or looped back, or none (user-selectable);
02/04/2010
#24985
3 of 5
Download from Www.Somanuals.com. All Manuals Search And Download.
Connectors —
Indicators — ACU1006RA, ACU1012RA, ACU1006DRA, ACU1006SRA,
ACU1006DSRA, ACU1006VRA, ACU1006DVRA: Front-mounted LEDs
(1 for each port) for power and link integrity;
ACUREM, ACUSREM, ACUMREM, ACUVREM, ACUWREM, ACUREMSW,
ACU1006MRA, ACU1006MRVA: None
All: Power: (1) IEC 320 M to 2.5-mm center-positive barrel connector;
ACU1006RA, ACU1012RA:
Interconnect: (6) or (12) RJ-45;
CPU: (6) or (12) DB25 F;
ACU1006DRA:
Interconnect: (6) RJ-45;
Temperature Tolerance —
Operating: 32 to 104°F (0 to 40°C);
CPU: (6) DB25 F;
Keyboard and mouse: (12) 6-pin mini-DIN F;
Monitor: (6) HD15 F;
Storage: -40 to +176°F (-40 to +80°C)
Humidity Tolerance —
5 to 90% noncondensing
ACU1006SRA:
Interconnect: (6) RJ-45;
Enclosure — Steel
Power —
CPU: (6) DB25 F, (6) DB9 F;
ACU1006DSRA:
Interconnect: (6) RJ-45;
To local hub:
5 VDC at up to 120 mA from each attached CPU’s keyboard and
mouse ports;
CPU: (6) DB25 F, (6) DB9 F;
Keyboard and mouse: (12) 6-pin mini-DIN F;
Monitor: (6) HD15 F;
ACU1006VRA:
Interconnect: (6) RJ-45;
CPU: (6) DB25 F, (6) DB9 F;
Audio I/O: (12) 3.5-mm stereo sockets;
ACU1006DVRA:
Optionally, from desktop power supply, PSU1006E-R2 (certified to
the relevant international safety standards):
Input: 100 to 240 VAC at 47 to 63 Hz from utility-power
(mains) outlet, through detachable power cord and
IEC 320 M inlet, to external transformer;
Output: 5 VDC regulated, at 1.5 amps minimum, from
transformer to local hub;
To remote unit:
Interconnect: (6) RJ-45;
From desktop power supply, PSU1002E-R3 (certified to the
relevant international safety standards):
Input: 100 to 240 VAC at 47 to 63 Hz from utility power outlet,
through detachable power cord and IEC 320 M inlet, to
external transformer;
CPU: (6) DB25 F, (6) DB9 F;
Keyboard and mouse: (12) 6-pin mini-DIN F;
Monitor: (6) HD15 F;
Audio I/O: (12) 3.5-mm stereo sockets;
ACUREM, ACUMREM:
Interconnect: (1) RJ-45;
Keyboard and mouse: (2) 6-pin mini-DIN F;
Monitor: (1) HD15 F;
ACUSREM:
Interconnect: (1) RJ-45;
Keyboard and mouse: (2) 6-pin mini-DIN F;
Monitor: (1) HD15 F;
Output (isolated from mains ground): 9 VDC regulated,
at up to 1 amp, from transformer to remote unit
Size — ACU1006RA, ACU1012RA, ACU1006DRA, ACU1006SRA,
ACU1006DSRA, ACU1006VRA, ACU1006MRA, ACU1006MRVA:
1.75"H x 19"W x 4.5"D (4.4 x 48.3 x 11.4 cm);
ACU1006DVRA: 3.5"H x 17.3"W x 4.5"D (8.9 x 43.9 x 11.4 cm);
ACUREM, ACUSREM, ACUREMSW: 1.4"H x 7"W x 3.9"D
(3.6 x 17.8 x 9.9 cm);
Serial: (1) DB9 F;
ACUVREM, ACUWREM:
Interconnect: (1) RJ-45;
Keyboard and mouse: (2) 6-pin mini-DIN F;
Monitor: (1) HD15 F;
Audio I/O: (2) 3.5-mm stereo sockets;
Serial: (1) DB9 M;
ACUMREM: 1.5"H x 3.1"W x 4.3"D (3.8 x 7.9 x 10.9 cm);
ACUVREM: 1.4"H x 7.8"W x 3.9"D (3.6 x 19.8 x 9.9 cm);
ACUWREM: 2"H x 3.1"W x 4.3"D (5.1 x 7.9 x 10.9 cm)
Weight —
ACU1006RA, ACU1006DRA, ACU1006SRA, ACU1006VRA,
ACU1006DVRA: 3 lb. (1.4 kg);
ACU1012RA: 4.3 lb. (2 kg);
ACUREMSW:
Interconnect: (1) RJ-45;
Keyboard and mouse: (2) 6-pin mini-DIN F;
Monitor: (1) HD15 F;
ACU1006DSRA: 6.6 lb. (3 kg);
ACUREM, ACUSREM, ACUVREM, ACUWREM: 1.1 lb. (0.5 kg);
ACUMREM: 0.5 lb. (0.2 kg);
ACUWREMSW: 1.4 lb. (0.6 kg);
Switch: (1) DB25 F;
ACU1006MRA, ACU1006MRVA: 4 lb. (1.8 kg)0
ACU1006MRA:
Interconnect: (6) RJ-45;
Keyboard and mouse: (12) 6-pin mini-DIN F;
Monitor: (6) HD15 F;
ACU1006MRVA:
Interconnect: (6) RJ-45;
Keyboard and mouse: (12) 6-pin mini-DIN F;
Monitor: (6) HD15 F;
Audio I/O: (12) 3.5-mm stereo sockets;
Serial: (6) DB9 F
02/04/2010
#24985
4 of 5
Download from Www.Somanuals.com. All Manuals Search And Download.
Item
Code
What’s included
First, choose the hub for your application…
Rackmount ServSwitch Brand CAT5 KVM Extender Hubs
6-Port Standard
When you order a Rackmount ServSwitch Brand CAT5
KVM Extender Hub, you’ll also receive:
✦ (1) 5-VDC (1.5 amps or higher) power-supply transformer
and output cord for optional video power
✦ (1) input cord for the optional power supply, suitable
for your country or region
aCU1006ra
aCU1012ra
aCU1006Dra
aCU1006sra
aCU1006Dsra
12-Port Standard
6-Port Dual-Access
6-Port with Serial
6-Port Dual-Access with Serial
6-Port with Serial and Bidirectional Stereo Audio
aCU1006Vra
6-Port Dual-Access with Serial and Bidirectional Stereo
Audio aCU1006DVra
✦ (1) users’ manual
…then order a remote unit for each active hub port…
Standalone Remote Units
Standard
When you order a Standalone Remote Unit, you’ll also receive:
ACU1006RA:
top: front view;
bottom: rear view
✦
(1) 9-VDC, 1-amp power-supply transformer and output cord
aCUreM
Serial
Micro
aCUsreM
aCUMreM
aCUVreM
aCUWreM
aCUreMsW
✦ (1) power-supply input cord suitable for your country
or region
✦ (1) users’ manual
Serial and Bidirectional Stereo Audio
Micro with Serial and Bidirectional Stereo Audio
with Integrated KVM Switch
When you order a Rackmount Remote Unit, you’ll also receive:
✦ (1) 9-VDC, 1-amp power-supply transformer and output cord
✦ (1) power-supply input cord suitable for your country
or region
✦ (1) pair of rackmount ears for 19" rack
✦ (1) users’ manual
You can also choose rackmount remote units with six units
in a chassis…
Rackmount Remote Units
Micro (ACUMREM)
Micro with Serial and Bidirectional Stereo Audio
(ACUWREM)
aCU1006Mra
aCU1006MrVa
For optimum performance and a 20% savings, order…
Category 5 Solid-Conductor Cable, 4-Pair, Straight-Pinned
Preterminated Patch Cable (Specify Length)
100-MHz Bulk Cable, 1000-ft. (304.8-m)
eYN737Ms
PVC
Spool
Box
eYN840a-1000
eYN840a-B
What else you might need:
Plenum-Rated
• Solid-core 4-pair Category 5 UTP or STP, pinned
and paired according to TIA/EIA-568A or (preferably) TIA/EIA-
568B, to run from your hub to your remote unit. (Bulk CAT5
cable should be terminated with high-quality RJ-45 plugs.)
To use Category 5e or Category 6 cable, call Black Box for
technical support.
• CPU extension cables.
• Serial extension cables.
• A 19" rack or cabinet.
• A monitor for each user station (each monitor must work
when attached directly to any of the CPUs connected
to the extender).
• A standard IBM PC/AT or PS/2 keyboard for each
user station where users will need keyboard control.
• A standard PS/2 compatible mouse for each user station
where users will need mouse control.
Spool
Box
eYN860a-1000
eYN860a-B
Coaxial CPU Cable for CAT5 KVM Extenders
3-ft. (0.9-m)
10-ft. (3-m)
eHN230-0003
eHN230-0010
eHN230-0015
eDN12H-MF
15-ft. (4.6-m)
DB9 Extension Cable, Male/Female
You may also need…
➝
AT®
PS/2® Mouse GHOST Emulator
aC244a
5-Pin DIN Male to 6-Pin Mini-DIN Female Keyboard Adapter
Fa222-r2
19" Rackmount Kit
9-Volt Power Supply
5-Volt Power Supply
If you want to use Cat5e or Cat6 cable, order…
ServSwitch Brand CAT5 Extender Delay Line Module
rMK19U-r2
PsU1002e-r3
PsU1006e-r2
aCUDLY
For better twisted-pair performance, choose…
ServSwitch Wizard™ Skew Compensator
aCU5100a
02/04/2010
#24985
5 of 5
Download from Www.Somanuals.com. All Manuals Search And Download.
|