July 2005
LBH150A(AE) -H, -P
LBH240A(AE) -H, -P
LBH600A(AE) -H, -P
Heavy Duty Edge Switches
© Copyright 2005.
Black Box Corporation. All rights reserved.
Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX
FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746
Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018
CUSTOMER
SUPPORT
INFORMATION
1000 PARK DRIVE • LAWRENCE, PA 15055-1018 • 724-746-5500 • FAX 724-746-0746
Web site: www.blackbox.com
•
E-mail: [email protected]
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box Heavy Duty Edge Switches
Installation and User Guide (07/05)
Contacting Black Box Corporation
Please use these mailing address and phone and fax numbers:
Black Box Corporation
1000 Park Drive
Pittsburgh, PA 15055
Phone: (724) 746-5500
Fax: (724) 746-0746
E-mail: [email protected]
__________________________________________________________
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box Heavy Duty Edge Switches
Installation and User Guide (07/05)
FEDERAL COMMUNICATIONS COMMISSION
AND
CANADIAN DEPARTMENT OF COMMUNICATIONS
RADIO FREQUENCY INTERFERENCE STATEMENTS
This equipment generates, uses, and can radiate radio frequency energy and if not
installed and used properly, that is, in strict accordance with the manufacturer’s
instructions, may cause interference to radio communication. It has been tested and
found to comply with the limits for a Class A computing device in accordance with the
specifications in Subpart B of Part 15 of FCC rules, which are designed to provide
reasonable protection against such interference when the equipment is operated in a
commercial environment. Operation of this equipment in a residential area is likely to
cause interference, in which case the user at his own expense will be required to take
whatever measures may be necessary to correct the interference.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box Heavy Duty Edge Switches
Installation and User Guide (07/05)
This digital apparatus does not exceed the Class A limits for radio noise emission from
digital apparatus set out in the Radio Interference Regulation of the Canadian
Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites
applicables aux appareils numériques de la classe A prescrites dans le Règlement sur le
brouillage radioélectrique publié par le ministère des Communications du Canada.
NORMAS OFICIALES MEXICANAS (NOM)
ELECTRICAL SAFETY STATEMENT
INSTRUCCIONES DE SEGURIDAD
1.
2.
Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato
eléctrico sea operado.
Las instrucciones de seguridad y operación deberan ser guardadas para referencia futura.
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser
respetadas.
4. Todas las instrucciones de operación y uso deben ser seguidas.
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box Heavy Duty Edge Switches
Installation and User Guide (07/05)
5.
El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo, cerca de la tina de baño,
lavabo, sótano mojado o cerca de una alberca, etc..
6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean
reconnendados por el fabricante.
7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recommendado por el
fabricante.
8. Servicio—El usuario no debe intentar dar sercicio al equipo eléctrico más allá a lo descrito en
las instrucciones de operatión. Todo otro servicio deberá ser referido a personal de servicio
calificado.
9. El aparato eléctrico debe ser situado de tal mannera que su posición no interfiera su uso. La
colocación del aparato eléctrico sobre una cama, sofá, alfombra o superficie similar puede
bloquea la ventilación, no se debe colocar en libreros o gabinetes que impidan el flujo de aire
por los orificios de ventilación.
10. El equipo eléctrico deber ser situado fuera del alcance du fuentes de calor como radiadores,
registros de calor, estufas u otros aparatos (incluyendo amplificadores) que producen calor.
11. El aparato eléctrico deberá ser connectado una fuente de poder sólo del tipo descrito en el
instrucivo de operación, o como se indique en el aparato.
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box Heavy Duty Edge Switches
Installation and User Guide (07/05)
12. Precaución debe ser tomada de mal manera que la tierra fisica y la polarización del equipo no
sea eliminada.
13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni
pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los
contactos y receptáculos donde salen del aparato.
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recommendaciones del
fabricante.
15. En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia.
16. El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo
periodo de tiempo.
17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la
cubierta u orificios de ventilación.
18. Servicio por personal calificado deberá ser provisto cuando:
A: El cable de poder o el contacto ha sido dañado; u
B: Objectos han caído o líquido ha sido derramado dentro del aparato; o
C: El aparato ha sido expuesto a la lluvia; o
D: El aparato parece no operar normalmente o muestra un cambio en su desempeño;;o
E: El aparato ha sido tirado o su cubierta ha sido dañada.
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box Heavy Duty Edge Switches
Installation and User Guide (07/05)
Certification Notice for
Equipment Used in Canada
The Canadian Department of Communications label identifies certified equipment. This
certification means that the equipment meets certain telecommunications-network
protective, operation, and safety requirements. The Department does not guarantee the
equipment will operate to the user’s satisfaction.
Before installing this equipment, users should ensure that it is permissible to be
connected to the facilities of the local telecommunications company. The equipment
must also be installed using an acceptable method of connection. In some cases, the
company’s inside wiring associated with a single-line individual service may be extended
by means of a certified connector assembly (extension cord). The customer should be
aware that compliance with the above conditions may not prevent degradation of service
in some situations.
Repairs to certified equipment should be made by an authorized Canadian maintenance
facility—in this case, your supplier. Any repairs or alterations made by the user to this
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box Heavy Duty Edge Switches
Installation and User Guide (07/05)
equipment, or equipment malfunctions, may give the telecommunications company cause
to request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of the
power utility, telephone lines, and internal metallic water pipe system, if present, are
connected together. This precaution may be particularly important in rural areas.
CAUTION:
Users should not attempt to make such
connections themselves, but should contact
the appropriate electric inspection authority,
or electrician, as appropriate.
The LOAD NUMBER (LN) assigned to each terminal device denotes the percentage of
the total load to be connected to a telephone loop which is used by the device, to prevent
overloading. The termination on a loop may consist of any combination of devices,
subject only to the requirement that the total of the load numbers of all the devices does
not exceed 100.
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box Heavy Duty Edge Switches
Installation and User Guide (07/05)
TABLE OF CONTENTS
Page
1.0
1.1
1.2 Summary of models and descriptions................................................... 10
SPECIFICATIONS (HEAVY-DUTY EDGE SWITCHES) .............. 1
Technical Specifications ..................................................................... 1
2.0
INTRODUCTION ............................................................................... 12
Inspecting the Package and the Product............................................. 12
Product Description ........................................................................... 13
Frame Buffering and Latency ............................................................ 22
Features and Benefits......................................................................... 26
Applications for Heavy-Duty LBHXXX Edge Switches.................. 29
INSTALLATION................................................................................. 37
Locating the Edge Switch Unit.......................................................... 37
LH1505-RACK for Rack Mounting of Heavy-Duty LBH Switches. 38
LH1505-RACK-1-9V and LH1505-RACK-2-9V ............................. 40
DIN-Rail mounting option................................................................. 41
Power Requirements, Power Supply Types....................................... 42
Powering the LBHXXXA(E)-H and -P (DC internal)....................... 44
2.1
2.2
2.3
2.4
2.5
3.0
3.1
3.2
3.3
3.4
3.4
3.5
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box Heavy Duty Edge Switches
Installation and User Guide (07/05)
3.6 DC Power Terminals: “+”, “-”, gnd......................................................... 46
3.7
3.8
LBHXXXA(E)-H and -P Series, DC-powered,................................. 47
Connecting Ethernet Media ............................................................... 48
Connecting Twisted Pair............................................................ 50
Connecting Fiber Optic ST-type, “twist-lock”........................... 50
Connecting Fiber Optic SC-type, "Snap-In".............................. 51
Connecting Single-Mode Fiber Optic........................................ 52
Power Budget Calculations........................................................ 53
Connections to NICs.................................................................. 55
3.8.1
3.8.2
3.8.3
3.8.4
3.8.5
3.8.6
4.0
4.1
OPERATION ....................................................................................... 56
Dual-Speed Functionality, and Switching ......................................... 56
Auto-cross (MDIX),........................................................................... 58
Dual LEDs, Front-panel and side-panel............................................. 59
4.2
4.3
4.4 Hardware operated Alarm Contact .......................................................... 60
5.0
TROUBLESHOOTING ...................................................................... 61
Before Calling for Assistance ............................................................ 62
When Calling for Assistance ............................................................. 63
5.1
5.2
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box Heavy Duty Edge Switches
Installation and User Guide (07/05)
5.3
Return Material Authorization (RMA) Procedure............................. 65
Revisions
Rev A 06/05: Initial release of this user manual for Heavy Duty Edge Switches
Black Box. reserves the right to change specifications, performance characteristics and/or model
offerings without notice.
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
SPECIFICATIONS (Heavy-Duty Edge Switches)
Technical Specifications
1.0
1.1
Ports Performance
When a port is operating at 100Mbps:
Data Rate: 100Mbps
When a port is operating at 10 Mbps:
Data Rate: 10 Mbps
Network Standards
100Mb: Ethernet IEEE 802.3u, 100BASE-TX, 100BASE-FX
10 Mb: Ethernet IEEE 802.3, 10BASE-T
Auto-sensing for speed: IEEE 802.3u
Packet-Processing Between Domains
Filter and Forward Rate from 100Mbps ports: 148,800 pps max
Filtering and Forwarding Rate from 10 Mbps ports: 14,880 pps max.
Processing type: Store and Forward, non-blocking
Auto-learning: 2K address table
Address buffer age-out time: 300 sec.
Packet buffers memory: 128KB, dynamically shared on all domains
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
Latency (not including packet time):
100 to 10 Mbps: 5µs
10 to 100Mbps: 15µs
Path Delay Value: 50 BT on all ports
LLL(Link-Loss-Learn): Factory default is activated on port 1 and 2
(allow to flush the internal address buffer , and qualify to use STP/RSTP for
faster recovery in ring topology)
Maximum Ethernet Segment (or Domain) Lengths
10BASE-T (Unshielded twisted pair)
100BASE-TX (CAT 5 UTP)
100BASE-FX, half-duplex: (multi-mode)
100BASE-FX, full-duplex: (multi-mode)
100BASE-FX, half-duplex: (single-mode)
- 100 m (328 ft)
- 100 m (328 ft)
- 412 m (1350 ft)
- 2 km (6,562 ft)
- 412 m (1350 ft)
100BASE-FX, full-duplex: (single-mode)
- 20 km (65,620 ft)
100BASE-FX, full-duplex: (single-mode, long reach) - 40 km (131,240 ft)
2
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
Operating Environment
LBHXXXA(E):
32ºF to 104ºF (0ºC to 40ºC)
LBHXXXA(E)-H: -13ºF to 140ºF (-25ºC to 60ºC) Long term per agency tests (UL).
-40ºF to 149ºF (-40ºC to 85ºC) Short term per IEC Type tests.
LBHXXXA(E)-P: -40ºF to 167ºF (-40ºC to 75ºC) Long term per agency tests (UL).
-58ºF to 212ºF (-50ºC to 100ºC) Short term per IEC Type tests.
Storage Temperature,
All models:
-40ºF to 160ºF (-40ºC to 85ºC)
Cold Start:
LBHXXXA(E)-H to -20ºC
LBHXXXA(E)-P to -40ºC
Ambient Relative Humidity: 5% to 95% (non-condensing)
Altitude (All models):
-200 to 5000ft. (-60 – 15,000 m)
Conformal Coating (optional) for humidity protection
Note: H and Extreme models are designed for NEBS compliance, including, vibration,
shock and altitude.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
Packaging:
Enclosure: Rugged sheet metal (Steel).
Dimensions of the Switch unit:
3.7 in H x 3.0 in W x 1.7 in D (9.4 cm x 7.6 cm x 4.3 cm)
Weight: all models: 13 oz. (370g);
Power supply, A, and AE: 5.8 oz (165g)
A–H, and AE-H: 5.8 oz (165g)
A–P, and AE-P: 7.9 oz (225g)
Cooling Method:
Convection on the office model. The Hardened (H) factory floor and Extreme (P)
temperature un-controlled location models have closed cases to withstand dirt and use
special thermal techniques to transfer heat to the outside of the case for cooling.
ALARM RELAY Terminal Block, H and P models only, two screw terminals:
Internal 60VA relay contact: Open for power Off, closed for power On (Hardware).
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
POWER SUPPLY
These products are intended to be supplied by a Listed, Direct Plug-In power unit, marked
“Class 2”, or a Listed ITE Power Supply, marked “LPS”, which has suitably rated output
voltage (i.e. 9vdc, 12vdc, 24vdc, 48vdc), and suitably rated output current (i.e. 100mA to
500mA).When connected to a 48V centralized DC source, these products shall be provided
with a Listed 5 A DC fuse in the supply circuit.
Direct DC POWER SUPPLY : built-in terminal
block for +, -, ground along with 12VDC jack
12V DC internal (range 8.0 to 15V DC),
24V DC internal (range 10 to 36V DC),
-48V DC internal (range 30 to 60V DC),
AC POWER SUPPLY ( using an external power adapter):
All models have an (8-15)VDC output with 6ft long cord and a 2.5mm center + jack. The
external AC power supplies are temperature rated to match the Edge Switch ratings.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
Office Models Ratings (0 to 40°C)
North America (A) models. Input: direct plug-in 95-125vac at 60 Hz.
Output:12vdc, 1Amps
International (AE) models. Input: 240vac at 50Hz with IEC 320 connector for the user
supplied AC power cord.
Output:12vdc, 1Amps
Factory Floor Models (H) Ratings (-25 to 60°C)
North America (A-H) models. Hardened, factory floor temperature rated. Input: 6ft AC
3power cord to IEC 320 connector on the 100-240vac 47-63Hz external power adapter.
Output:12vdc, 1.25Amps
International (AE-H) models. Factory floor temperature rated. Input: IEC 320 connector
on the 100-240vac 47-63Hz external power adapter. Requires a user supplied power cord
Output:12vdc, 1.25Amps.
Temperature un-controlled Extreme (P) Ratings (-40 to 75°C)
North America (A-P) models. Outdoor temperature rated. Input: 6ft AC power cord to
IEC 320 connector on the100-240vac 47-63Hz external power adapter.
Output:12vdc, 2Amps.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
International (AE-P) models. Outdoor temperature rated. Input: IEC 320 connector on
the 100-240vac 47-63Hz external power adapter. Requires a user supplied power cord.
Output:12vdc, 2Amps.
Note: LH1505-CK - For Hardened or Extreme -24VDC unit only for dual DC power (sold
separately). See 3.6.
Power Consumption: See Section 3.6.
Note 1: the 12V DC jack can be used for dual source DC input using an AC adapter and
the DC terminal block. Power supply protection is provided by internal diodes.
Note 2: The Direct DC power floats. The user may ground either “+” or “-” if desired.
Power Consumption, all models: 7.0 watts typical, 9.0 watts max.
Port Connectors:
RJ-45 Ports: support 100BASE-TX and 10BASE-T with auto-cross (MDIX).
They are shielded 8-pin female connectors for shielded (STP) and unshielded
(UTP) Cat 3, 4, 5 cable.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
Fiber optic port: supports 100Base-FX with a “fiber flavor” choice of multimode
SC, ST, LC or MTRJ or single mode SSC, SSCL, SST or SLC connectors. (By
default factory settings is at “Full” duplex on fiber ports)
LED Indicators (Front)
POWER: Steady ON when power applied
10/100: Steady ON for 100Mbps; OFF for 10 Mbps(copper ports only)
LK/ACT: Steady ON for LINK (LK) with no traffic, BLINKING indicates
port is transmitting / receiving (ACT).
F/H:
Steady ON for full-duplex, OFF for half-duplex (Fiber port only)
Mounting options
Metal mounting clips for panel mounting: included
DIN-Rail mounting option: Model # DIN_RAIL_MC2 (see Section 3.4)
Rack-mount option: Model # LH1505-RACK (see Section 3.2)
Depth: 6.0”, width: 17” Height: 2.25” (15cm D x 43cm W x 5.7cm H)
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
Mean Time Between Failure (MTBF) – over15 years, Telcordia (Bellcore) Method
Agency Approvals and Standards Compliance:
UL Listed (UL 60950), cUL, CE, Emissions meets FCC Part 15 Class A.
NEBS L3 and ETSI compliant.
Hardened and Extreme models: IEEE 1613 Env. Std for Electric Power Substations
Extreme models: NEMA TS-2 and TEES for traffic control equipment
Extreme models: designed for UL 2043 above-the-ceiling installation
IEC61850 EMC and Operating Conditions Class C Power Substations
Made in USA
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
1.2 Summary of models and descriptions
Note: The LBH150, LBH240 and LBH600 model # consists of the base unit, for domestic power
supply add A, for international power supply add AE, fiber interface xx and the dc power option yy.
(see note for xx and yy) In three different temperatures range Standard, Hardened and Extreme.
Standard for office and wiring closet (0 to 40C) using an external AC power supply.
LBH150A(E)-xx = one 100Mb fiber port + five 10/100 RJ-45
LBH240A(E)-xx = two 100Mb fiber port + four 10/100 RJ-45
LBH600A(E) = six 10/100 RJ-45
Hardened (H) for factory floor (-25 to 60C) using a direct DC ( 8-15VDC) and/or external AC
hardened power supply (included).
LBH150A(E)-H-xx-yy = one 100Mb fiber port + five 10/100 RJ-45
LBH240A(E)-H-xx-yy = two 100Mb fiber port + four 10/100 RJ-45
LBH600A(E)-H-yy = six 10/100 RJ-45
Extreme (P) for un-controlled (outdoor) (-40 to 75C) using direct DC (8-15VDC) and/or external AC
Extreme power supply (included).
LBH150A(E)-P-xx-yy = one 100Mb fiber port + five 10/100 RJ-45
LBH240A(E)-P-xx-yy = two 100Mb fiber port + four 10/100 RJ-45
LBH600A(E)-P-yy = six 10/100 RJ-45
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Note: xx for fiber interface
Installation and User Guide(07/05)
“SC” = 100Base-FX-SC: multi-mode fiber optic with SC type connector, 2km.
“SSC”= 100Base-FX-SSC: single-mode fiber optic with SC type connector, 20km.
“SSCL”= 100Base-FX-SSCL: single-mode fiber optic with SC type connector, 40km.
“ST” = 100Base-FX-ST: multi-mode fiber optic with ST type connector, 2km.
“SST” = 100Base-FX-ST: single-mode fiber optic with ST type connector, 2km.
“SLC”= 100Base-FX-SLC: single-mode fiber optic with LC type connector, 15km.
“MT”= 100Base-FX-MTRJ: multi-mode fiber optic with MTRJ type connector, 2km.
Note: yy for dc power options
“12” = 12 VDC
“24” = 24 VDC and HD and PD for DIN Rail mounts bracket included
“48” = -48 VDC
without the –yy unit is AC powered.
Accessories
LH1505 = 19” Rack-mount tray for LBH150, LBH240 and LBH600 Switch models, up to 8 units
Other Tray configurations with power supplies and power cabling included - See Section 3.3
LH1505-CK= Cable kit for 24VDC input power input jack for one of any 24VDC model
DIN-RAIL MC2 = Metal DIN-Rail mounting bracket for one Heavy-Duty LBH150, LBH240 and
LBH600 Switch, -See Section 3.4
Conformal Coating (for high humidity and “tropical” applications) - request quote.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
2.0 INTRODUCTION
Installation and User Guide(07/05)
This section describes LBHXXX Series models, including appearance, features
and typical applications.
2.1 Inspecting the Package and the Product
Examine the shipping container for obvious damage prior to installing this
product; notify the carrier immediately of any damage which you believe occurred during
shipment or delivery. Inspect the contents of this package for any signs of damage and
ensure that the items listed below are included.
This package should contain:
1
LBHXXX Series Heavy-Duty Edge Switch unit,
External Power Supply, (not with DC powered models)
Metal panel mounting clips and screws (2 each)
User Guide (this manual)
1
1 set
1
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
Remove the Black Box LBHXXX Series Edge Switches from the shipping
container. Be sure to keep the shipping container should you need to ship the unit at a later
date. In the event there are items missing or damaged contact your supplier. If you need to
return the unit use the original shipping container. Refer to Section 5 Troubleshooting, for
specific return procedures.
2.2 Product Description
Black Box Heavy-Duty Edge Switches (LBHXXX -Series) are designed as an
Ethernet edge solution in industrial, military and un-controlled temperature applications, as
well as an economical solution for the growing requirements of managed networks.
LBHXXX-Series, a six port versatile family of compact Edge switches, loaded with factory
configurable fiber options and AC/DC power input options with Alarm terminal block and
innovative packaging is ready to serve the needs of edge-of-the network applications.
The Heavy-Duty (LBHXXX) family of Edge Switches have a wide breadth of
port configurability and fiber port type options - six 10/100 copper ports or four 10/100
copper ports and two 100 Mb Fiber port or five copper ports with one 100Mb Fiber port
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
built in, covers the full range of application environments, with regular (office), Hardened
(factory floor), and Extreme-rated (outdoor) versions. Extra features for Heavy-
Duty(LBHXXX )and extended temperature operation ranges are included selectively in the
Hardened factory-floor and Extreme-rated outdoor models. The breadth of models and
flavor of fiber port types offers the best price-to-value ratio for each user and installation.
The compact package is ideal for network edge installations, and is able to be conveniently
Din rail mounted to suit any application.
The Black Box Edge switches include Link-Loss-Learn(LLL) feature (factory
configurable on ports 1 and 2 to qualify for any redundant and self-healing managed
network structures. The Link-Loss-Feature in LBHXXX-Series allows the Edge switches to
flush the internal address buffers in milliseconds to permit a quick change in LAN packets
flow, and pass the reconfiguration signal down the line to other ring switches in the
redundant structure for faster recovery. Black Box Edge switches, combined with other
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
Black Box managed switches, running STP/RSTP, can often provide high availability
Redundant LANs at economical cost.
The Heavy-Duty LBHxxx-Series regular-package units are for office
and indoor wiring closet environments. These are the economical base units in the
LBHxxxA Switch family. An external AC power
supply for either North America (-d, 115vac 60Hz)
or international (-I, 230vac, 50Hz) is included. The
ambient temperature rating is 0°C to 40°C, office
grade. Fig 2.2a LBH600A with SIX 10/100 RJ-
45 only
Fig 2.2 a
A robust metal case with convection
cooling is featured. Metal mounting clips are included, and rack-mount tray options are
available.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
Fig 2.2 b Fig 2.2b (LBH150A-SC) left with four10/100 RJ-45 and two fiber 100Mb
The Regular Heavy-Duty LBHXXX Edge Switches
models (as shown in Fig 2.2.a, b,) units are for
office and wiring closet environments and use an
external AC power supply. A ventilated metal case
for convection cooling is featured. Ambient
operating temperature is 0° to 40°C. Storage
temperature rating is -40°to 85°C. Metal clips are
included for secure panel mounting and optional
DIN-Rail mounting. The regular models also has a rack-mount option via an
MC-TRAY.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
The regular model LBHXXXA, includes Link-Loss-Learn, MDIX ports and the full range of
fiber port options. The regular LBH150A/LBH240A model does not have options for
Alarm and DC power
The Hardened labeled Heavy-Duty LBHXXXA-H
Edge Switches H units (shown in Fig 2.2c & d)
are designed for factory floor/Industrial
applications. Using special thermal techniques
and a sealed rugged metal case for heavy duty
industrial applications, the Hardened LBHXXXA-H
requires no air inflow for cooling, so the
LBHXXXA-H resists dirt, moisture, smoke and insects.
Fig. 2.2.c Hardened LBH150A-H-ST
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
The Heavy-Duty LBH150A-H/LBH240A-H Edge Switches, Hardened units are for
factory floor applications. The LBHXXXA-H
models are built with high-grade
components and are constructed using
special thermal techniques and a metal case
for heavy duty Fig. 2.2.d Hardened
LBH240A-H-ST industrial jobs.
In addition to a Hardened AC power option
and jack, terminals for internal DC power
choices at 8 to15V, 24V or -48V DC are
included. The ambient temperature rating of –25 to 60C is for industrial use. No internal air
flow is required for cooling, so it resists dust, dirt, moisture, smoke and insects. Mounting
options include stand-alone panel-mounting, DIN-Rail, or rack-mount tray. Choices of
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
models for external AC or internal DC power are available. Ambient operating temperature
is –25°C to + 60°C depending on the power source
used. Storage
temperature rating is –25°C to + 85°C.
Fig 2.2e & f,
Extreme
model
LBH240A-
P-ST
LBH600A-P
The Extreme labeled Heavy-Duty
LBHXXXA(E)-P Edge Switches Extreme-rated units are
for temperature un-controlled applications (-40 to
75°C), typically located outdoors. The LBHXXXA(E)-P models are built with premium-grade
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
extended temperature components, and use similar thermal techniques as the LBHXXXA-H
Hardened units. In addition to a Extreme-rated AC power option and jack, terminals for
internal DC power choices at 8 to15V, 24V or -48V DC are included. When used outdoors,
the LBHXXXA-P should be protected from rain.
Mounting options include stand-alone panel-mounting, DIN-rail, or rack-mount tray. The
LBHXXXA-P series (as shown in Fig. 2.2f & g) are Extreme rated units suitable for
temperature un-controlled outdoor applications. Specially designed with premium-grade
extended temperature components, the LBHXXXA-P units use similar thermal techniques to
the LBHXXXA-H hardened units for cooling. Mounting options include panel-mounting,
DIN-rail, or rack-mount tray. Choices of models for external AC or internal DC power are
available. Ambient operating temperature is between –40°C to +75°C depending on the
power source used. Storage temperature rating is between –40°C to +85°C.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
All the Extreme and hardened models also come along with hardware
operated Alarm terminal block for providing extra reliability to the unit. The Alarm feature
allows the LBHXXX heavy duty users to be aware and to monitor any internal power
failure. See section 44 for details.
The front side of the unit has four/five twisted-pair 10/100Mb switch ports and
one/two 100Mb fiber port. All the RJ-45 ports of the Heavy-Duty LBHXXX Edge switches
support auto-cross (MDIX) operation under auto-negotiation mode. The Heavy-Duty
LBHXXX provides switching among four 10/100 auto-negotiating copper ports and two
100Mb fiber ports which may be SC, ST, MTRJ or LC multi-mode or single-mode. The
LBHXXX’s breadth of fiber options and well as temperature options provide many
networking options and solutions in a very small footprint.
Two sets of LEDs to indicating the operating status of ports are mounted on the
top and front (for extra viewing advantage while rack-mounted). For each port, there are
Link and Activity (LK/ACT) LED’s on the top indicating that the media cables are
Fig 2.2c
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
connected correctly and showing, by blinking, when there is traffic. The LK/ACT LED’s
are repeated on the front as 1 (port 1)…6 (port 6), whereas on the side as LA1…LA6 .
There is another set of LEDs on the front for 10 or H and 100 or F, to indicate the data rate
as well as a set to indicate duplex for ports 1 and 2 only. 10/100 indicates the speed for
copper ports, whereas F/H indicates Full and Half duplex for fiber ports only.
There is a power (PWR) LED to indicate that the unit is turned ON. The fiber
ports on the LBHXXX Edge switches are multi-mode or single-mode with an SC, ST or
small form factor connector (MTRJ multi mode or LC single-mode).
The external DC power plug connector and/or “jack” and the internal DC input
terminal is provided on the rear of the unit.
2.3 Frame Buffering and Latency
The Heavy-Duty LBHXXX Series Edge Switches are store-and-forward
switches. Each frame (or packet) is loaded into the Switch’s memory and inspected before
forwarding can occur. This technique ensures that all forwarded frames are of a valid
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
length and have the correct CRC, i.e. they are good packets. This eliminates propagation of
bad packets, enabling all of the available bandwidth to be used for valid information.
While other switching technologies such as "cut-through" or "express" impose
minimal frame latency, they will also permit bad frames to propagate to the Ethernet
network. The "cut-through" technique permits collision fragment frames, which are a result
of late collisions, to be forwarded--which add to the network traffic. There is no way to
filter frames with a bad CRC (the entire frame must be present in order for CRC to be
calculated). Since collisions and bad packets are more likely when traffic is heavy, store-
and-forward switch technology enables more bandwidth to be available for good packets
when the traffic load is greatest.
To minimize the possibility of dropping frames on congested ports, each Heavy-
Duty LBHXXX Edge Switch dynamically allocates buffer space from 128KB memory
pool, ensuring that heavily used ports receive very large buffer space for packet storage.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
(Many other switches have their packet buffer storage space divided evenly across all ports,
resulting in a small, fixed number of packets to be stored per port. When the port buffer
fills up, dropped packets result.) This dynamic buffer allocation provides the capability for
the maximum resources of the Heavy-Duty LBHXXX Edge Switches unit to be applied to
all traffic loads, even when the traffic activity is unbalanced across the ports. Since the
traffic on an operating network is constantly varying in packet density per port and in
aggregate density, the Heavy-Duty LBHXXX Edge Switches are constantly adapting
internally to provide maximum network performance with the least dropped packets.
When the Switch detects that its free buffer queue space is low, the Switch sends
industry standard (full-duplex only) PAUSE packets out to the devices sending packets to
cause “flow control”. This tells the sending devices to temporarily stop sending traffic,
which allows a traffic catch-up to occur without dropping packets. Then, normal packet
buffering and processing resumes. This flow-control sequence occurs in a small fraction of
a second and is transparent to an observer.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
Another feature implemented in Heavy-Duty LBHXXX Edge Switches is a collision-based
flow-control mechanism (when operating at half-duplex only). When the Switch detects
that its free buffer queue space is low, the Switch prevents more frames from entering by
forcing a collision signal on all receiving half-duplex ports in order to stop incoming traffic.
The latency (the time the frame spends in the Switch before it is sent along or
forwarded to its destination) of the Heavy-Duty LBHXXX Edge Switches varies with the
port-speed types. The length of the frame is a variable as it is with all store-and-forward
switches. For 10 Mb-to-10 Mb, 10 Mb-to-100Mb or 100Mb-to-10 Mb forwarding, the
latency is 15 microseconds plus the packet time of 10 Mb. For 100Mb-to-100Mb
forwarding, the latency is 5 microseconds plus the packet time of 100Mb.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
2.4 Features and Benefits
ꢀ
Full 100Mb or 10 Mb switching services for high performance Ethernet
Black Box Heavy-Duty LBHXXX Switches provide Fast Ethernet switching
on all ports. They perform high speed filter/forward operations on the
traffic, giving each port’s segment a full 100Mb (or 10 Mb) of bandwidth.
ꢀ
Reduces Network Costs and provide economical solution
Black Box Heavy-Duty LBHXXX Switches offer the ideal solution to
efficiently and inexpensively connect a Twisted Pair and fiber network with
10Mb or 100Mb and help to expand the Ethernet network in a very
convenient and economical way.
ꢀ
Choice of one or two100Mb Fiber option, more efficient
Designed as a multi-purpose media Edge Switch, the 100Mb fiber port
allows the user to convert the media from copper to fiber and the other RJ-
45 port can be used as diagnostic port or for more connectivity.
26
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
ꢀ
Installation is “Plug and Play”, operation is transparent to software
The Black Box Heavy-Duty LBHXXX Switches operate as hardware
switches, only forwarding those packets from each domain that are needed
on the other domains. Internal address tables are self-learning, enabling
users to change port connections or 10/100 domains without affecting
operations.
ꢀ
ꢀ
Two sets of LEDs for viewing status from any angle.
Each LBHXXX Edge Switch is equipped with two sets (front and side) of
LEDs to provide status information when viewed at almost any angle or
mounting arrangement whether rack LH1505P-RACK or Din-Rail mounted.
Rugged metal case, Industrial grade
LBHXXX have a robust design and are packaged in a rugged sheet metal
enclosure to ensure high reliability and durability even when placed in
industrial or outdoor applications.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
ꢀ
Qualified to use for temperature un-controlled “outdoor” application
The Black Box LBHXXXA(E)-P Extreme rated versions of Edge Switches have
an ambient temperature rating between –40ºC to +75ºC for DC models and
qualify for temperature un-controlled “outdoor” application.
ꢀ
Efficient Compact design, for all purpose convenient mounting
Featuring a compact steel case with an external AC and internal DC power
supply, Black Box Heavy-Duty LBHXXX of Edge Switches can be installed
in small spaces in cabinets, on table tops, in racks, walls or DIN-Rail
mounted and in trays such as the Black Box LH1505P-RACK.
ꢀ
MDIX ports to eliminate cross-over cable while cascading All the Black
Box Heavy-Duty LBHXXX Switches are featured with MDIX (auto-cross),
which easily allow cascading with other Switch, Hubs or media Edges
without using the cross-over cable.
28
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
ꢀ
Hardware operated Alarm terminal block for LBHXXXA(E)-H and
LBHXXXA(E)-P
The Alarm contact option on LBHXXXA(E)-H and LBHXXXA(E)-P enables
monitoring for internal power failure, and provides extra reliability to the
hardened Switch
ꢀ
Link-Loss-Learn feature for faster recovery in redundant managed
network
The LLL feature qualifies the Edge switches to actively work along with
redundant network structure as a client switch and allow a faster recovery
during ring break.
2.5 Applications for Heavy-Duty LBHXXX Edge Switches
Available in three “hardness” models (“office/wiring closet”, “Hardened”, “Extreme rated
(outdoor)”), and hundreds of port-type combinations, Black Box Heavy-Duty LBHXXX
Edge Switches fit very well in almost any environment to enable users to scale their
networks quickly and cost effectively. The edge-of-the-network connectivity solutions
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
offered by Black Box Edge Switches provide convenient, economical, and reliable
solutions as well as an active role on the managed redundant network setup for faster
recovery. The compact Black Box Heavy-Duty LBHXXX assists fast expanding network
requirements via providing edge support and reliability to the managed redundant network.
The Dual-Speed and Dual-media functions support a mixed environment of 10 Mbps and
100Mbps users with copper and fiber media. The switched full duplex fiber ports also
provide high bandwidths and longer distance support. The up-link feature of 100Mb fiber
on Ports 1 and 2 enable easy expansion for the on-going demand of Ethernet networks. The
10/100Mbps auto-negotiating MDIX copper ports and the breadth of 100Mbps fiber ports
enable easy interfacing with existing cable plant and equipment. Models of LBHXXX Edge
Switches are available for even the most extreme temperatures. The LBHXXX’s rugged
case provides extra support in the harshest industrial environments. Link-Loss-Learn is an
additional feature to provide the extra reliability to the redundant network and an
economical solution for faster recovery, during the ring break.
30
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
Example1. Supermarket application for LBHXXX- In this example, the supermarket
required a Data Mining function to store all the transaction with an ongoing demand to
expand the network. This need can be easily met using the economical Black Box
LBHXXX Edge Switch. Additional functionality includes the ability to transfer data
Router
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
across large distances with multi- or single–mode fiber while securing the LAN from EMI
and wire tapping.
The LBHXXX’s six ports in a small, reliable metal enclosure provide an effective
solution to for transferring real-time transactions from the store to the storage device in the
control room. The easily deployable through Din-rail option and the dual power source of
flexibility along with flavor of fiber option for distance, the LBHXXX easily meets all the
requirements of supermarket. The plug-n-play LBHXXX not only provides a reliable
solution but also reduces operational costs significantly.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
Example 2: LBHXXXA(E)-H and LBH100AE
In this industrial networking application, the new PLC units are deployed on a network
expansion, and each PLC required one (or two for redundancy) Ethernet ports to carry
status and control data to the control center. The LBHXXXA and LBH100A provide a
good solution with their multiple options and hardened features. The two Fiber ports on the
Edge switches are ideal for secure data communications over long distances. Built with
high-grade components, efficient cooling techniques and having no openings for dirt to
enter, the Heavy-Duty LBHXXX Edge Switches provide the very effective solution for this
need. The LBH100A media converter switch offers additional and affordable fiber
connectivity to the LBHXXXA(E)-H where needed. The sleek and reliable design of it not
only being deployed easily in industrial environment but also provide an effective
economical solution.
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
PLC
PLC
PLC
Internet
Router
PLC
PLC
PLC
PLC
PLC
PLC
PLC
34
PLC
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
Example 3: LBHXXXA(E)-P: In this example, the Black Box LBHXXXA(E)-P Extreme
Edge Switches are deployed to serve as a secure corporate or transportation surveillance
system. CCTV cameras may be spread out over many miles in temperature un-controlled
locations and with pan, tilt and zoom (PTZ) controlled through an Ethernet copper port. The
premium Edge Switches provide two fiber segments for secure long distance (2-40km)
communication while being installed in temperature un-controlled cabinets and allowing a
full range of AC and DC power options. The four copper ports at the remote location
provides access for other Ethernet equipment such as motion detectors or will act as a test
port for maintenance personnel with up-link for access to a central LAN and central file
servers. The application of video conferencing and capturing the events and transfer to the
central location is coming out as a useful application in lots of location of traffic or industrial
floor. The ideally-suited LBHXXXA(E)-P with its diversified features, premium-rated approvals
and cost-effective solutions, make an ideal choice in outdoor environments.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
Interne
Router
CCTV
CCTV
CCTV
CCTV
36
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
3.0 INSTALLATION
Installation and User Guide(07/05)
This section describes the installation of the Black Box Heavy-Duty LBHXXX
Edge Switches, including location, mountings,
power supply options and media connection.
3.1 Locating the Edge Switch Unit
All the Heavy-Duty LBHXXX Switches
operate in transparent half-and full-duplex
mode. The store and forward switch easily
takes care of network traffic and can be used
as a useful, economical tool to expand an
existing network.
Secure attachment of mounting
clips for panel - mounting
The compact and lightweight design of the Black Box Heavy-Duty LBHXXX
allows it to be easily installed in almost any location. A Velcro strip may be used for
37
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
mounting the unit on a vertical surface such as a wall or cabinet, or for securing the unit on
a table-top or shelf. Alternatively, metal mounting clips and screws are included for a
rugged and secure mounting in any orientation.
Installation of the Black Box Heavy-Duty LBHXXX Edge Switches is a simple
procedure. The installation location is dependent upon the physical layout of the Ethernet
network and associated cabling. Make sure the unit is installed in a location that is easily
accessible to an AC power outlet or the appropriate DC source and where cooling is not
inhibited. The green Power (PWR) LED must turn ON when power is applied.
3.2 LH1505-RACK for Rack Mounting of Heavy-Duty LBH Switches
For 19” rack-mounting of Black Box Heavy-Duty LBHXXX Edge Switches, a rack-mount
tray is available, the LH1505P-RACK. The Edge Switches are mounted with the DC power
jack in the back, with the fiber and the RJ-45 connectors in the front. Any mix of the Edge
38
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
Switches and/or Media Edges may be placed on a tray, up to a maximum of 8 units. (The
mounting spaces of the
LH1505P-RACK are
specific to the Black Box
products and will not permit
other models to be properly
mounted).
In a typical installation, the
LH1505P-RACK, 19” rack-
mount tray will hold a few (three to eight) Heavy-Duty LBHXXX Edge Switches, with
their power supplies plugged into power strips (not included) in the rear area of the tray.
Metal mounting screws in the bottom-front hold the Edge Switches firmly in place. The
39
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
beveled-top edge of the units permits the LEDs of each unit to be viewed for operational
status, even when the units are very close together.
3.3 LH1505-RACK-1-9V and LH1505-RACK-2-9V
for Rack Mounting Media Edges
The LH1505-RACK-1-9V and LH1505-RACK-2-9V
are other options for rack mounting the mix of Black
Box 10Mbps and 100Mbps Edge Switches and Media
Edges together in a 19” rack-mount tray. These models
come with built-in common universal AC power
supply rated at 55 watts at 50°C ambient,9VDC
output, and supporting up to 2-3 Switches for
LH1505-RACK-2-9V and 5 units Heavy-Duty
LBHXXX for LH1505-RACK-1-9V. The LH1505-
RACK-2-9V Model has two groups of Four units per
power supply. The power supplies have auto-ranging
AC input for use worldwide.
40
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
The side-view < here is an example of an installation of the model LH1505P-RACK, 19”
rack-mount tray, holding a few LBHXXX, and LBH100A, each with their power input
plugged into the built-in common AC power supply in the rear area of the tray. (AC PS
units that come with the office models of the Edge Switch’s are not used). Because of the
thicker size, only eight LBHXXX units can
LH1505P-RACK.
fit in one
Metal mounting screws in the
bottom-front hold each of the Edge Switches,
securing them in the tray and enabling
separate removal for service. The dual LEDs
permit viewing of Edge Switch status from
any angle.
3.4 DIN-Rail mounting option
The Black Box LBHXXXH and
LBHXXXA(E)-P Edge Switches, designed for use
in “Factory Floor” Industrial Ethernet environments, are available for DIN-Rail mounting
in an enclosure having DIN Rails. A Black Box LBH240A-H is shown alongside the
DIN-Rail- bracket here ->
41
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
The metal DIN-Rail mounting hardware is optional and needs to be ordered as a
separate item, e.g. Model #XXXXX. It comes with four screws to attach the bracket to the
MC unit. The rail clip is spring-loaded with a pull-up latch at the top for easy “snap-on”
attachment and removal.
The Black Box LBHXXX models with “HD” and
“PD” have 24VDC power, and have the DIN-
Rail- bracket included and assembled with the
unit at the factory.
3.4 Power Requirements, Power Supply Types
for Heavy-Duty LBHXXX Switches
Black Box Heavy-Duty LBHXXX Switches are
power-efficient and can work with an external AC
power supply. Black Box Heavy-Duty LBHXXX
require a nominal 12VDC input version. LBH150A-
H or Extreme with 12VDC/ 24VDC/ -48VDC
42
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
The extended temperature (H and P) versions are used for heavy duty industrial
applications. The 12V DC power input jack has a plug of 2.5mm, center +ve , with 6 ft.
cord. All the AC power supply info detail is provided in Technical Specs Section 1.1.
The Heavy-Duty LBHXXX are designed to be used with UL listed Class II power supplies.
The LBHXXX Edge Switches provide reliable operation, withstand higher temperature
environments, and provide the DC power choices to the user to deploy in uncontrolled
temperature environments. The Direct DC (Internal) 12V DC (8 – 15V DC) has a built-in
terminal block for +, -, ground. The 9V DC jack is also present. Detail information about
the 12 VDC, the 24V DC and the –48V DC is provided in the Technical Specifications
Section 1.1. The various models of DC power type and extended ambient temperature
power supplies are numerous and your choice needs to be called out on your order.
Note: When connected to a -48 V centralized dc source these products are to be installed
only in Restricted Access Areas (dedicated equipment rooms, electrical closets or the like).
43
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
3.5 Powering the LBHXXXA(E)-H and LBHXXXA(E)-P (DC internal)
with 12V, 24V or –48VDC power input
Each Black Box LBHXXXA(E)-H/LBHXXXA(E)-P Series
is equipped with an internal DC power supply,
and has built-in screw terminals for secure
attachment of the power input leads. Three DC
power models support a range of power input
types. The three DC power input terminal block
choices are for use with 12VDC, 24VDC or -
48VDC power. Where an AC power adaptor is
used, DC is supplied via the jack. Power input from
the DC
terminal block and the jack and both may be connected simultaneously for power input
redundancy.
44
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
Note:The LBHXXXA(E)-H or P models with 24VDC
support the Dual Source 24V input option. An
external LH1505-CK (SHOWN AT RIGHT…and
sold separately, or a customer-supplied
equivalent) can be used to input 24VDC power
to the LBHXXXA(E)-H or P unit via the jack. This is
for 24VDC models only.
45
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
3.6 DC Power Terminals: “+”, “-”, gnd
GND: Terminal for “earth” or ground wire connection to the LBHXXXA(E)-H chassis
Input Voltage: 12VDC
24VDC
-48VDC
Alarm
Contact
Terminal
24VDC
(10-36VDC)
-48VDC
(30-60VDC)
12VDC
(8-15VDC)
(12V)
(8-15VDC)
(12V or 24V)
(10-30VDC)
(12V)
(8-15VDC)
Input
current:
0.8 amp.(12V DC)
0.4 amp max.(24V DC)
0.2 amp max.(-48V DC)
Power Consumption:7.0 watts typical, 9.0 watts max.
46
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
3.7 LBHXXXA(E)-H and P Series, DC-powered,
12VDC, 24VDC and -48VDC Installation
This section describes the proper
connection of the -48VDC leads (or 24VDC,
12VDC leads) to the DC power terminal block
on the Black Box LBHXXXA(E)-H Edge Switch (a
shown in the Figure). The DC terminal block on
the Black Box LBHXXXA(E)-H is located on the left
side of the unit and is equipped with three (3) screw-down lead posts. The power terminals
are identified as positive (+) and negative (-), and they are floating inside the unit so that
either of the terminals may be grounded by the user if desired. The chassis is “earth” or
ground (GND). The connection procedure is straightforward. Simply insert the DC leads to
47
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
the LBHXXXA(E)-H’s power terminals, positive (+) and negative (-) screws. The use of Ground
(GND) optional; it connects to the Edge Switch chassis. Ensure that each lead is securely
tightened from the top, as shown on above picture with arrow.
NOTE: Always use a voltmeter to measure the voltage of the incoming power supply
and figure out the +ve potential lead or -ve potential lead. The more +ve potential lead
will connect to the post labeled “+ve” and the rest to the “-ve”.
The GND can be hooked up at the last.
When power is applied, the green PWR LED will illuminate.
3.8 Connecting Ethernet Media
The Black Box LBHXXX-Series Edge Switches can be connected to two media
types i.e. fiber and copper (RJ-45) types, runt at 100BASE-TX, 10BASE-T and 100BASE-
FX only. CAT 5 cables should be used when making 100BASE-TX connections. When the
ports are used as 10BASE-T ports, CAT 3 may be used. In either case, the maximum
48
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
distance for unshielded twisted pair cabling is 100 meters (328 ft). For fiber port 10BASE-
FL or 100BASE-FX multi-mode, 50/125 or 62.5/125 microns cabling can be used, whereas
for single-mode, 9/125 microns cabling should be used. Fiber cabling supports much longer
cable distance and higher bandwidths as compared to copper wiring.
Media
IEEE Standard
10BASE-T
Connector
RJ-45
Twisted Pair (CAT 3 or 5)
Twisted Pair (CAT 5)
Fiber (Multi-mode)
Fiber (Single-mode)
Fiber (Multi-mode)
100BASE-TX
100BASE-FX
100BASE-FX
100BASE-FX
RJ-45
ST, SC
SC, LC
MTRJ
NOTE : It is recommended that high quality CAT. 5 cables (which work for both 10 Mbps
and 100Mbps) be used whenever possible in order to provide flexibility in a
mixed-speed network, since LBHXXX-series switch ports are auto-sensing for
either 10 and 100Mbps. Note that the auto-cross function does not operate, if the
port is fixed or not supporting auto-negotiation.
49
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
3.8.1 Connecting Twisted Pair
Installation and User Guide(07/05)
(RJ-45, CAT 3 or CAT 5, Unshielded or Shielded)
The following procedure describes how to connect a 10BASE-T or 100BASE-TX
twisted pair segment to the RJ-45 port. The procedure is the same for both
unshielded and shielded twisted pair cables.
1. Using standard twisted pair media, insert either end of the cable with a RJ-45 plug
into the RJ-45 connector of the port. Note that, even though the connector is
shielded, either unshielded or shielded cables and wiring may be used.
2. Connect the other end of the cable to the corresponding device.
3. Use the LINK LED to ensure proper connectivity by noting that the LED will be
illuminated when the unit is powered and proper connection is established. If this
does not help, ensure that the cable is connected properly and that the device on the
other end is powered and is not defective.
4. All the RJ-45 ports are AUTO-Cross (MDIX), and will automatically determined
the Link, while linking to another hub or Switch.
3.8.2
Connecting Fiber Optic ST-type, “twist-lock”
The following procedure applies to installations using ST-type fiber connectors.
This procedure applies to ports using multi-mode ST fiber connectors.
50
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
1. Before connecting the fiber optic cable, remove the protective dust caps from the
tips of the fiber connectors. Save these dust caps for future use.
2. Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens tissue
dampened in alcohol. Make certain the connectors are clean before connecting.
Note:
One strand of the duplex fiber optic cable is coded using color bands
at regular intervals; you must use the color-coded strand on the associated
ports at each end of the fiber optic segment.
3. Connect the Transmit (TX) port (light colored post) on the Black Box Fiber port to
the Receive (RX) port of the remote device. Begin with the color-coded strand of
the cable for this first TX-to-RX connection.
4. Connect the Receive (RX) port (dark colored post) to the Transmit (TX) port of the
remote device. Use the non-color coded fiber strand for this.
5. The LINK LED on the front of the fiber connector will illuminate when a proper
connection has been established at both ends (and when power is ON in the unit). If
LINK is not lit after cable connection, the normal cause is improper cable polarity.
Swap the fiber cables at the fiber connector to remedy this situation.
3.8.3
Connecting Fiber Optic SC-type, "Snap-In"
The following procedure applies to installations using SC-type fiber
connectors, i.e., using multi-mode SC and SC single-mode. While connecting
51
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
fiber media to SC connectors, simply snap on the two square male connectors
into the SC female jacks of the Fiber connector until it clicks and secures.
3.8.4
Connecting Single-Mode Fiber Optic
When using single-mode fiber cable, be sure to use single-mode fiber port
connectors. Single-mode fiber cable has a smaller diameter than multi-mode
fiber cable (9/125 microns for single-mode, 50/125 or 62.5/125 microns for
multi-mode where xx/xx are the diameters of the core and the core plus the
cladding respectively). Single-mode fiber allows full bandwidth at longer
distances, about 20Km with the multi-mode SC.
The same procedures as for multi-mode fiber apply to single-mode
fiber connectors. Follow the steps listed in Section 3.8.2 above.
52
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
3.8.5 Power Budget Calculations
Installation and User Guide(07/05)
for Heavy-Duty LBHXXX, Fiber Media
Receiver Sensitivity and Transmitter Power are the parameters necessary to
compute the power budget. To calculate the power budget of different fiber media
installations using Black Box products, the following equations should be used:
OPB (Optical Power Budget) = PT(min) - PR(min)
where PT = Transmitter Output Power, and PR = Receiver Sensitivity
Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)
Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]
where the “Cable Loss” for 62.5/125 and 50/125µm (m.m.) is 2.8 dB/km,
and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,
and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km
and the “Cable Loss” for 9/125 (Single-mode) is 0.25 dB/km (SSCX)
The following data has been collected from component manufacturer’s (Agilent’s, JDS-
Uniphase, stratus, Lucents’) web sites and catalogs to provide guidance to network
integrators and installers-
53
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
Fiber
Port
Module
Speed,
Std.
Std. kmWavel Cable X’mitr R’cvr Worst Worst* typical typical*
fdx ength Size Output Sens. OPB, distance OPB, distance
Mode
(hdx) nm
PT , dB PR ,dB dB Km, fdx
dB Km, fdx
µm
LBHXXX-
MST, MSC
Multi-
mode (0.4)
2
62.5/125 -20 -31
50/125 -23.5 -31
9.0
5.5
2.5
2.0
14
12
5
4
100Mb
FX
1310
Single- 20
mode (0.4)
100Mb
FX
LBHXXX-
SSC
1310 9/125
-15
-31
14
28
17.5
35
Multi-
mode (0.4)
2
62.5/125 -20
-31
9.0
5.5
3.0
2.0
15.8
12.2
5.5
4.0
100Mb
FX
LBHXXX-
MTRJ
1310
1310
50/125 -23.5 -31
Single-
40
mode
(0.4)
100Mb
FX
9/125
-5
-15
-5
-34
-28
-35
-32
27
54
32.5
65
Long Reach
Single-
15+
11
22
-
-
100Mb
FX
LBHXXX-
LC
9/125
1310
1550
mode
Single-
mode
100Mb
FX
LBHXXX-
SSCX
100
9/125
9/125
28
14
112
28
-
-
-
-
Single-
20
mode
(0.4)
100Mb
FX
-16
LBHXXX-
1310
54
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
* Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed
over long distances (i.e., over approx. 400 meters) can be achieved only if the following
factors are both applied:
•
•
The 100Mb fiber segment must operate in full-duplex (FDX) mode, and
The worst-case OPB of the fiber link must be greater than the fiber cable’s
passive Attenuation.
(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)
3.8.6
Connections to NICs
which support Auto-Negotiation, RJ-45 ports
The copper ports of Black Box LBHXXX-Series Edge Switches will function
properly with NICs (Network Interface Cards) which support Auto-Negotiation, and the
Fast Link Pulse (FLP) coding for the 100BASE-TX signaling system. When connecting a
NIC to the LBHXXX-Series, it may be necessary to reload the NIC drivers on the user
device if the NIC has been communicating with a protocol other than 100BASE-TX (such
as 10BASE-T). When 100Mb operation is agreed and in use, the 10/100 LED is
illuminated steady ON and is OFF, if 10 Mbps traffic.
55
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
4.0 OPERATION
Installation and User Guide(07/05)
4.1 Dual-Speed Functionality, and Switching
The Black Box Heavy-Duty LBHXXX Edge Switches provide SIX
switched ports with combination of fiber and copper or copper only. The architecture
supports a dual speed switching environment, with standard auto-negotiation capability.
The switched RJ-45 ports are full- or half-duplex auto-sensing for mode and
speed, and auto-cross for plug polarity. (See Section 4.2). When the connected device is 10
Mbps, the LBHXXXs obeys all the rules of 10 Mbps Ethernet configurations. The 10 Mbps
users can “communicate” with 100Mbps users as well as other 10 Mbps users through the
switch. Similarly, the 100Mbps traffic obeys the rules of 100Mbps Ethernet, and can
communicate with 10 Mb and 100Mb users. Black Box Heavy-Duty LBHXXX units are
plug-and-play devices. There is no software configuring to be done at installation or for
maintenance, even for the LLL ports. The internal functions of both are described below.
56
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
Switching, Filtering and Forwarding
Each time a packet arrives on one of the switched ports, the decision is taken to either filter
or to forward the packet. Packets whose source and destination addresses lie on the same
port segment will be filtered, constraining them to one port and relieving the rest of the
network from processing them. A packet whose destination address is on another port
segment will be forwarded to the appropriate port, and will not be sent to the other ports
where it is not needed. Packets needed for maintaining the operation of the network (such
as occasional multi-cast packets) are forwarded to all ports. The Black Box Heavy-Duty
LBHXXX Edge Switches operate in the store-and-forward switching mode, which
eliminates bad packets and enables peak performance to be achieved when there is heavy
traffic on the network.
Switching, Address Learning
The Black Box Heavy-Duty LBHXXX units have address table capacity of
2K node addresses, and are suitable for use in large networks. They are self-learning, so
that as nodes are added or removed or moved from one segment to another, the
LBHXXX- Series switch automatically keeps up with node locations.
An address-aging algorithm causes least-used addresses to fall out in favor of
new frequently-used addresses. To reset the address buffer, cycle power down-and-up.
57
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
4.2 Auto-cross (MDIX),
Auto-negotiation and Speed-sensing
The RJ-45 ports independently support auto-cross (MDI or MDIX) in auto-
negotiation mode and will work properly with all the other connected devices with RJ-
45 port whether it supports Auto-negotiation or not (e.g 10Mb Hub) or fixed mode at
10Mb or 100Mb Half/Full Duplex(managed switch). No cross-over cable is required
while using the LBHXXX’s Auto-negotiation port to other devices. Operation is
according to the IEEE 802.3u standard.
When a RJ-45 cable connection is made, and each time a LINK is enabled,
auto-negotiation takes place. The Black Box Heavy-Duty LBHXXX advertises its
capability for 10 or 100 Mbps speed and F/H duplex mode, and the device at the other
end of the cable should similarly advertise / respond and both sides will agree to the
speed and mode being used. Depending upon the device connected, this will result in
agreement to operate at either 10 Mbps or 100Mbps speed, full- or half-duplex mode.
Even a managed switch will connect at fixed mode (100Mb Full Duplex), the
LBHXXX will connect at 100Mb Half duplex only. Since the Auto-negotiating
LBHXXX will advertise the speed only and not look for the duplex mode set on the
other side.
58
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
4.3 Dual LEDs, Front-panel and side-panel
(Black Box Heavy-Duty LBHXXX)
LED
Description
PWR
Illuminates GREEN to indicate power applied.
LK/ ACT Steady ON for LINK w/no traffic, blinking for activity per port. LINK will turn
off in the event connectivity is lost between the ends of the twisted pair segment
or a loss of power occurs in the unit or remote device. The Link ports are also
represented by LA1, LA2, LA3…LA6. (Steady On or steady Off indicates no
Receive Activity).
10/100 Steady ON for 100Mb speed, OFF for 10Mb speed per port (copper ports)
F/H (FH1, FH2) Steady ON for Full duplex (F/D) mode, OFF for Half duplex (H/D)
mode per port (For fiber port only)
NOTE: The port#1 and 2 is being assigned for copper or fiber port for different models. On
all copper 10/100 ports model (e.g LBHXXXA), the LEDs 10 or 100 denotes for
copper port only. For the model 4copper +2 fiber or 5copper +1fiber,(e.g
LBHXXXA(E)-H-xx-yy) the xx denotes for fiber port only.
59
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
4.4 Hardware operated Alarm Contact
for monitoring internal power supply
The two screws Alarm Contacts feature, standard on Black Box LBHXXXA(E)-H
and P, provides Normally Closed (NC) contacts to which the user can attach one sets of
status monitoring wires at the green terminal block. When this option is present, the
terminal block for Alarm Contacts is part of the Power Input panel in the Black Box
LBHXXXs case. The DC power input connection is in the same panel.
The NC Alarm Contact is held close when there is power on the
main board inside of the LBHXXX. This provides a
“Hardware operated Alarm” because the NC
contacts will open when internal power is lost,
either from an external power down condition
or by the failure of the power supply inside of
the Black Box LBHXXX Switch.
60
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
Useful info about Alarm Contacts in LBHXXXA(E)-H and LBHXXXA(E)-P:
1. Two-position terminal block (1,2) provided next to the DC power input, as shown above.
2. The Alarm Relay contact connected to the two terminals (1,2) is hardware operated.
3. By default it is NC (normally closed). It will open if there is any loss of power to the
electronics inside of the unit.
5.0
TROUBLESHOOTING
All BLACK BOX®Ethernet products are designed to provide reliability and
consistently high performance in all network environments. The installation of LBH1xxA
Series 10/100 Mb/s Switches is a straightforward procedure (see INSTALLATION, Section
3.0); the operation is also straightforward and is discussed in Section 4.
Should problems develop during installation or operation, this section is intended
to help locate, identify and correct these types of problems. Please follow the suggestions
listed below prior to contacting your supplier. However, if you are unsure of the
61
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
procedures described in this section or if the LBHXXX Series 10/100 Mb/s Switch is not
performing as expected, do not attempt to repair the unit; instead contact your supplier for
assistance or contact BLACK BOX Customer Support.
5.1 Before Calling for Assistance
1.
2.
3.
If difficulty is encountered when installing or operating the unit, refer back
to the Installation Section of the applicable chapter of this manual. Also
check to make sure that the various components of the network are
interoperable.
Check the cables and connectors to ensure that they have been properly
connected and the cables/wires have not been crimped or in some way
impaired during installation. (About 90% of network downtime can be
attributed to wiring and connector problems.)
Make sure that an AC power cord is properly attached to each
LBH101A Series unit. Be certain that the AC power cord is plugged into a
functioning electrical outlet. Use the PWR LEDs to verify each unit is
receiving power.
62
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
4.
If the problem is isolated to a network device other than the LBHXXX and
LBHXXX Series 10/100 Mb/s switch product, it is recommended that
the problem device is replaced with a known good device. Verify whether or
not the problem is corrected. If not, go to Step 5 below. If the problem is
corrected, the LBHXXX Series Switch and its associated
cables are functioning properly.
5.
If the problem continues after completing Step 4 above, contact your supplier
of the LBHXXX Series 10/100 Mb/s Switch unit or if
unknown, contact BLACK BOX, Inc by phone at (724) 746-5500 or by
other appropriate method
5.2 When Calling for Assistance
Please be prepared to provide the following information.
1.
A complete description of the problem, including the following points:
a. The nature and duration of the problem;
b. Situations when the problem occurs;
c. The components involved in the problem;
d. Any particular application that, when used, appears to create the problem;
63
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
2. An accurate list of BLACK BOX product model(s)involved, with serial number(s).
Include the date(s) that you purchased the products from BLACK BOX.
3. It is useful to include other network equipment models and related hardware,
including Convenient computers, workstations, terminals and printers; plus, the
various network media types being used.
4. A record of changes that have been made to your network configuration prior
to the occurrence of the problem. Any changes to system administration
procedures should all be noted in this record.
64
Download from Www.Somanuals.com. All Manuals Search And Download.
Black Box® Heavy Duty Edge Switches
Installation and User Guide(07/05)
5.3 Return Material Authorization (RMA) Procedure
Shipping and Packaging Information
Should you need to ship the unit back to Black Box Corporation, please follow
these instructions:
1. Package the unit carefully. It is recommended that you use the original
container if available. Units should be wrapped in a "bubble-wrap" plastic sheet
or bag for shipping protection. ( You may retain all connectors and this
Installation Guide.)
CAUTION : Do not pack the unit in Styrofoam "popcorn" type packing material.
This material may cause electro-static shock damage to the unit.
2. Clearly mark the Return Material Authorization (RMA) number on the
outside of the shipping container.
3. Black Box Corporation is not responsible for your return shipping charges.
4. Ship the package to:
Black Box Corporation
1000 Park Drive
Lawrence, PA 15055
Phone: (724) 746-5500
Fax: (724) 746-0746
65
Download from Www.Somanuals.com. All Manuals Search And Download.
|