Belkin Marine Battery F5C412uk140W User Manual

AC Anywhere  
Power Inverter  
(Class II product)  
F5C412uk140W  
F5C412uk300W  
User Manual  
F5C412uk140W, F5C412uk300W  
Please read the installation and operations  
instructions before using the Power Inverters  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting:  
Problem:  
Solution:  
Equipment has a high start-up surge. Turn Inverter power switch OFF (O)  
and then ON (I) again until the  
Inverter powers your device. Repeat as  
necessary to get your device running.  
Automotive system  
Turn ignition key to accessory position.  
requires ignition to be on.  
Battery voltage below 10 volts.  
Recharge or replace battery.  
Equipment being operated  
draws too much power.  
Use a higher capacity Inverter  
or do not use this equipment.  
Inverter is too hot  
Allow Inverter to cool. Check for  
adequate ventilation. Reduce the load  
on the Inverter to rated continuous  
power output.  
(thermal shutdown mode).  
Inverter fuse is blown.  
Replace fuse according to guidelines  
in “Don’t Blow a Fuse” section of this  
manual. Make sure that the Inverter  
is connected to power source with  
correct polarity.  
Poor or weak battery condition.  
Replace battery.  
Inadequate power being delivered to  
Check condition of cigarette lighter  
the Inverter or excessive voltage drop. plug and socket. Clean or replace  
as necessary.  
Warning:  
• Improper use of this inverter can cause personnel injury, property damage,  
and or loss of life.  
• To avoid potential property damage, do not leave this inverter or any device  
operating unattended in vehicle.  
• Disconnect power to the inverter when it is not in use.  
• Do not use or place this inverter near flammable materials or any locations,  
which accumulate flammable fumes.  
• If the external flexible cable or cord of this power inverter is damaged, the  
manufacturer or his service agent or a similar qualified person shall replace  
it in order to avoid a hazard.  
• Regularly check that the input and output connections are tight. Loose  
connections can generate harmful heat and/or damage the inverter or  
power source.  
• This product is not recommended for use with inductive loads, such as  
florescent lamps, compressors & pumps. Otherwise, permanent damage may  
result.  
• This is not a toy. Keep away from reach of children.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To connect the Belkin 300-Watt Inverter directly to the 12-volt power source  
(battery), follow the steps as outlined below:  
1. Push the adapter plug leading from the Inverter firmly into the  
Direct-Connect Cable socket.  
2. Properly identify the positive (red) and negative (black) terminals on the  
12-volt power source and make certain that the terminals are clean and dry.  
3. Connect the RED alligator clip to the positive (+) terminal on the power  
source, and the BLACK alligator clip to the negative (-) terminal on the  
power source.  
4. Plug your equipment or appliance into the AC receptacle on the Inverter.  
5. Turn the Inverter’s power switch to the ON position.  
6. Confirm that the LED power indicator light on the Inverter is glowing  
GREEN. This means the Inverter is “ready for action.  
7. Turn on the equipment or appliance.  
Specifications  
F5C412uk140W  
F5C412uk300W  
Max.Continous Power  
Surge efficiency (Peak)  
No Load Current Draw  
Waveform  
140 Watt  
300 Watt  
<0.1 Amps  
300 Watt  
500 Watt  
<0.2 Amps  
Modified Sine Wave  
Operating Input Voltage Range  
Output Voltage Range  
Automatic Input Power Shutdown  
Output Frequency  
Fuse (Amperes)  
Space Fuse (Amperes)  
Lenght  
11-15 volts DC  
AC 240V ±5%  
10.4 Volts - 15 Volts  
50 Hz ±3Hz  
20 A  
30 A  
30 A  
20 A  
160 mm  
90 mm  
65 mm  
680 g  
yes  
160 mm  
90 mm  
65 mm  
680 g  
yes  
Width  
Height  
Weight  
Class II product  
Polarity  
negative (-)  
to ground  
negative (-)  
to ground  
Low battery alarm  
10.4 Volt  
9.8 Volt  
10.4 Volt  
9.8 Volt  
Low battery shutdown  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation:  
Power Source Requirements  
The power source must provides 12 Volts DC and must be able to supply the  
necessary current to operate the load. The power source may be a battery or  
a well-regulated 12V DC power supply. As a rough guideline, divide the power  
consumption of the load (in watt) by 12 (the input voltage) to obtain the  
current (in amperes) the power source must deliver. Example: Load is rated at  
120 Watts; the power source must be able to deliver: (220/12) = 18.3 Amps  
Making the Connection:  
The Belkin 140 and 300-Watt Inverters are designed to connect to your  
12-volt battery through the cigarette lighter socket on your dashboard.  
To connect and use these Inverters, follow these easy steps:  
1. Remove the cigarette lighter and push the adapter plug firmly into the  
socket. Make sure both the socket and adapter plug are clean and dry.  
2. Plug your appliance or equipment into the AC receptacle on the Inverter.  
3. Turn the Inverter rocker switch to the ON (l) position.  
4. Confirm that the LED Power Indicator light on the Inverter is glowing  
GREEN. This GREEN light indicates that your Inverter is “ready for action.”  
5. Turn on your equipment for use.  
Don’t Blow a Fuse:  
All Belkin Inverters are equipped with a spare fuse in case the original fuse  
should blow. Most blown fuses are the result of reverse polarity or a short  
circuit within the appliance or equipment being operated. With reasonable  
care, it should not be necessary to replace the fuse in your Inverter.  
To Replace a Fuse:  
Belkin 140-Watt / 300-Watt Inverter  
First, remove the power cord from the cigarette lighter socket. You will find  
fuse compartment is easily accessed at the back of the unit underneath the  
“lift-up” cover. Pull the blown fuse out, and insert the replacement. It is  
important to remember that to replace of fuse of the same type and rating as  
indicated. Make certain to correct the source of the overload that caused the  
blown fuse before turning your Inverter back ON.  
2. Replace the  
blown fuse with  
a new spade  
type fuse  
1. Open the fuse box cover  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The Power Source:  
When the engine is off, most batteries will provide an ample power supply  
to the Inverter for one to two hours. The actual length of time is a function  
of several variables including the age and condition of the battery, and the  
power demand being placed on it by the equipment being operated.  
If you are using the Inverter while the engine is off, we recommend you  
start the engine every hour and let it run for approximately 10 minutes to  
recharge the battery. We also recommend that the device plugged into the  
Inverter be turned off before turning over the engine.  
Although it is not necessary to unplug the Inverter when starting the  
engine, the Inverter may momentarily cease operation as the battery voltage  
decreases. When the Inverter is not supplying power, it draws very low  
amperage from the battery (< 0.1 amps to < 0.2 amps depending on the  
model) and may be left connected to the battery for up to 3 hours. However,  
we recommend the Inverter always be disconnected when not in use.  
Note:  
• Inverters will not operate with certain automotive systems unless the  
ignition is on. If the Inverter is not generating power, try turning the  
ignition to the accessory position.  
Automatic Shut-down and Related Safety Features:  
The Belkin 140 and 300-Watt Inverter models have a unique LED indicator  
warning light system that operates in conjunction with the automatic shut  
down feature. This indicator light operates as follows:  
RED - Overload/Low Battery  
Your Inverter will shut down automatically when any of the following  
problems occur:  
1. The power input from the battery drops below 10.4 volts.  
2. The power output from the battery exceeds 15 volts.  
3. The continuous draw of the device exceeds the design  
parameters of the Inverter.  
Battery Level Indicator  
Approximate State-of-charge  
Open Circuit Battery Voltage  
100%  
75%  
50%  
25%  
0%  
13.7  
12.7  
11.7  
10.7  
< 10.6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Additional Safety Features:  
1. Automatic shutdown when the internal circuit temperature exceeds  
standard design parameters for safe operation.  
2. Continuous audible alarm:  
a. When the input power from the 12-volt power source drops to 11 volts.  
b. When the internal circuit temperature exceeds standard design parameters  
for safe operation.  
In the event of automatic shut-down or continuous alarm, turn the Inverter  
rocker switch to the OFF (O) position until the source of the related problem  
has been identified and resolved.  
Note:  
• The Belkin 300W model is equipped with a cooling fan that is only designed  
to run continuously while the Inverter is operating. Automatic shutdown  
caused by excess circuit temperature occurs when the cooling fan is unable to  
maintain the design parameters for safe operation of the Inverter.  
To maintain your Inverter in proper working condition, note the following  
important safety precautions:  
• MOISTURE - Keep the Inverter dry. Do not expose it to moisture.  
• HEAT – The ambient air temperature should be between 50ºF and 80ºF,  
(approx. 17ºC - 27ºC). Avoid placing the Inverter on or near heat source.  
Do not place the Inverter in direct sunlight.  
• VENTILATION – In order to disperse the heat generated while the Inverter  
is in operation, keep it well ventilated. While in use, maintain several  
inches of clearance around the top and sides of the Inverter.  
Caution: Most automobole cigarette lighter circuits use  
fuses rated at 10-20 Amps.  
Battery Direct-Connect Cables:  
For the Belkin 300-Watt Inverter Only – F5C412uk300W  
Note:  
• If the equipment or appliance you intend to operate requires more than  
150 Watts of continuous power, the Belkin 300-Watt Inverter should be  
connected directly to the power source using the Battery Direct-Connect  
Cables. Failure to do so may result in serious damage to the power cord or  
to the cigarette lighter socket wiring in your vehicle.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAUTION:  
Applicable only for the : F5C412uk300w  
FOR USE WITH CIGARETTE LIGHTER PLUG:  
WARNING: If more than 150 Watts of AC power are required from the  
Inverter, DO NOT connect the Inverter through the vehicle’s cigarette  
lighter socket. THIS WILL OVERHEAT THE WIRES AND COULD CAUSE A  
FIRE. When using the devices that require a TOTAL of 150 Watts or more,  
connect the Inverter directly to the vehicle’s battery terminals using the  
provided Battery Clip.  
1. Insert Inverter’s Cigarette Lighter Plug into vehicle’s cigarette lighter  
socket.  
Note: Make sure Inverter is not ON when starting vehicle. If ON, a voltage  
surge from the vehicle could damage the Inverter or device lugged into it.  
2. Turn Inverter “ON” (Switch is located at front of unit, next to 220V electri-  
cal sockets). If the LED Status Light on Inverter illuminates GREEN, then  
the unit is functioning properly. If the LED Status Light on the Inverter  
illuminates RED, turn unit off immediately and check all connections.  
3. Plug device(s) (rated lower than 150W) into one of the 220V electrical  
sockets. Switch appliance(s) ON to begin operation. As long as LED  
Status Light on front panel of Inverter is GREEN, the device may  
be operated as normal.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONNECTION TO 12V BATTERY  
USING BATTERY CLIPS  
1. Insert the Inverter’s Cigarette Lighter Plug into the socket on the Battery Clip  
Connection Cable.  
2. Connect the Red (+) Battery Clip to 12V battery’s red (+) terminal. Connect the  
Black (-) Battery Clip to the battery’s black (-) terminal.  
3. Turn Inverter “ON. If the LED Status Light on Inverter illuminates GREEN, the  
unit is functioning properly. If the LED Status Light  
n the Inverter illuminates RED, turn unit off immediately and check  
all connections.  
4. Plug 220V appliance into one of the Inverter’s 220V AC Electrical Sockets.  
Switch appliance ON to begin operation. As long as Inverter’s LED Status Light  
remains GREEN, the device may be  
operated as normal.  
Note: Make sure Inverter is not ON when starting vehicle. If ON, a voltage surge  
from the vehicle could damage the Inverter or device plugged into it.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
On/Off  
Switch  
Battery Level  
Indicator Lights  
F5C412uk140W  
F5C412uk300W  
Child Protection  
built into socket  
Caution:  
Always match the  
“continuous wattage rating” of your  
device with the DC to AC Inverter  
capacity for best results.  
Belkin Ltd.  
Belkin GmbH  
Express Business Park  
Shipton Way  
Rushden NN10 6GL, United Kingdom  
+44 (0) 1933 35 2000  
+44 (0) 1933 31 2000 fax  
Hanebergstrasse 2  
80637 Munich  
Germany  
+49 (0) 89 143405 0  
+49 (0) 89 143405 100 fax  
Made in China  
Designed and Quality  
Assured in the U.S.A.  
Belkin B.V.  
Belkin SAS  
130 rue de Silly  
92100 Boulogne-Billancourt  
France  
+33 (0) 1 41 03 14 40  
+33 (0) 1 41 31 01 72 fax  
• P75043uk  
Boeing Avenue 333  
1119 PH Schiphol-Rijk  
The Netherlands  
© 2005 Belkin Corporation.  
All rights reser ved. All trade names  
are registered trademarks of  
+31 (0) 20 654 7300  
+31 (0) 20 654 7349 fax  
respective manufacturers listed.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Belkin Network Cables F5D4072 User Manual
Blanco Indoor Furnishings 501 108 User Manual
Bodum Coffee Grinder 10462 User Manual
Boss Audio Systems Car Amplifier BVAM5 User Manual
Briggs Stratton Portable Generator 40248 User Manual
Bryant Furnace 355CAV User Manual
Cannondale Bicycle Accessories 120858 User Manual
Canon Camcorder 30D User Manual
Casio Projector XJ UT310WN User Manual
Centro Gas Grill 3900S User Manual