Residential Gateway
(RG) Battery Backup
REV B
Save this user manual
This manual contains important instructions regarding the
installation and operation of this device. Read this manual
thoroughly before attempting to install or operate this device.
BU3DC001-12V
User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
This Residential Gateway (RG) Battery Backup, once properly installed and used,
has been designed to maintain your AT&T U-verseSM Voice service in the event
of a short disruption to your commercial power service.
Safety Information
CAUTION
Incorrectbattery connectionorreplacement creates risk of explosion. Risk of
Η
Energy Hazard, internal battery is 12VDC, 7.2 Ampere-hour. Before replacing
batteries, remove conductive jewelry such as chains, wrist watches, and rings.
Highenergythroughconductivematerialscouldcausesevereburns.
The RG Battery Backup is intended for installation and operation in a controlled
environment (temperature controlled, indoor area free of conductive contaminants).
Η
The unit shall be installed near an easily accessible power outlet.
No user serviceable parts exist inside the unit. Refer repair issues only to qualified
personnel. Fuses or other parts must be replaced ONLY with parts of identical
Η
types and ratings. Substitution of non-identical parts can cause fire and other
safety hazards.
t
All batteries used are sealed lead acid batteries. Battery should be recycled. Do not
Η
dispose of batteries in a fire. The batteries may explode. Do not open or mutilate
batteries. Released material is harmful to the skin and eyes. It may be toxic.
System Requirements
The RG Battery Backup is designed for use with the AT&T U-verseSM
Residential Gateway and your AT&T U-verseSM Voice service.
NOTE: Your AT&T U-verseSM Voice service, including 911 dialing, will not
function without electrical or battery-backup power. The RG Battery Backup
supplies power for your AT&T U-verseSM Voice service; it does not supply
power for cordless phones (and it does not supply power for your network
interface device or optical network terminal, typically located on the outside
of your home, which may also require battery-backup power for your
AT&T U-verseSM Voice service to function).
Therefore, in the event of a power outage, you should ensure you have one
corded single-line, touchtone phone connected directly to the AT&T U-verseSM
Residential Gateway or your in-home wiring and the AT&T U-verseSM
Residential Gateway connected to the RG Battery Backup. (Rotary/pulse
phones do not work with AT&T U-verseSM Voice service.) If you connect more
than one corded phone, it will use more power; if you connect a cordless phone,
it will not function without a separate battery backup, and not all cordless
phones are so equipped. If you have a monitored home alarm, you should never
plug a multi-line phone directly into the Residential Gateway—it could interfere
with the alarm signals. You should not connect the RG Battery Backup to
any device other than the AT&T U-verseSM Residential Gateway or use it with
any service other than your AT&T U-verseSM Voice service, and you should
always have an alternative means of dialing 911, such as via a cellular telephone.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Package Contents
You should have received the following:
1 – RG Battery Backup unit (12V sealed lead-acid battery included
inside unit )
Recycling
UNIT CONTAINS SEALED LEAD-ACID BATTERY. UNIT SHOULD BE
RECYCLED. Belkin International, Inc., advocates sound environmental
management of used batteries.
For battery replacement and recycling information, please call us at
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Controls and Status Indicators
Shown below are the controls and indicator lights on the RG
Battery Backup.
1
Power on/off
Power on/off switch is
located on the back panel.
Use this switch to turn
the RG Battery Backup on/
off. The unit will not supply
power to the AT&T
1
U-verseSM Residential
Gateway when power
switch is in OFF position.
2
3
Status Indicators
Three LED status lights are
located on the front panel.
The status lights indicate
specific conditions of the
device. (See page 6.)
2
Mute on/off
Use this switch to turn
the mute function on/off.
The audible alarms will be
silenced when mute switch
is in ON (down) position.
3
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Residential Gateway
(RG) Battery Backup
REV
B
Federal Communication Commission Interference Statement Subpart
This equipment has been tested and found to comply with the limits for
B
a
Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in residential installation. This equipment generates uses and can
a
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in
a
particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one of the following measures:
-
-
-
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on
a
circuit different from that
to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
-
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate this equipment.
Belkin Tech Support
US: 866-539-5791
Belkin International, Inc.
501 West Walnut Street
Los Angeles, CA 90220, USA
310-898-1100
310-898-1111fax
©
2010 Belkin International, Inc. All rights
reserved.
All trade names are registered trademarks of
manufacturers listed.
respective
REV 110309
8820-00299
BU3DC001-12V
Download from Www.Somanuals.com. All Manuals Search And Download.
Audible and Visual Alarms
The RG Battery Backup alarms to indicate certain events.
Front-Panel
Label
Visual
Audible
Alarm
Description
Indicator
On A/C
Green LED
lights
None
The RG Battery Backup is
operating on A/C.
Testing
Battery
Green LED
flashes
None
The RG Battery Backup is conduct-
ing a self-test. This procedure is
normal and will occur when the
self-test is manually initiated and
periodically thereafter (see page 8).
This procedure will last
approximately 5 minutes.
On
Yellow LED
lights
Tone every
10 seconds
The RG Battery Backup is
operating on battery power.
The alarm will stop when the A/C
power is restored.
Battery
Low
Yellow LED
flashes
Tone every
1 second
The battery energy is running low.
This alarm will continue until the
unit performs a forced shutdown
when the battery is depleted or A/C
power is restored.
Battery
Replace
Battery
Red LED
flashes
Tone every
5 seconds
The battery may have reached the
end of its useful life. Conduct a self
test (see page 8). If the alarm
remains on, replace the battery as
soon as possible to ensure proper
operation of the RG Battery Backup
(see page 9).
Fault
Red LED
lights
Continuous
tone
A fault has occurred. Reset the RG
Battery Backup (the unit) by:
* Turn off the unit
*
Disconnect unit from the AC outlet
* Reconnect unit to the AC outlet
* Turn on the unit
If the fault is not corrected, turn off
the unit and disconnect from the AC
outlet prior to checking Residential
Gateway. If fault persists, contact
Belkin for assistance.
NOTE: Audible alarm will not sound when mute switch is in ON position.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
NOTE: Before installation, please inspect the RG Battery Backup. Make sure
that nothing inside the package is damaged. The RG Battery Backup must
be installed near the Residential Gateway and be easily accessible.
STEP 1:
Connect to AC Utility Power
Make sure that the power switch on the RG Battery
Backup is in the OFF position. Plug the A/C cord on
the RG Battery Backup directly into a wall outlet. Do
not connect the RG Battery Backup into a power strip
or surge protector.
STEP 2:
Connect to the Residential Gateway
Connect the DC plug on the RG Battery Backup into
the Residential Gateway.
STEP 3:
Turning on the RG Battery Backup
Turn the switch on the RG Battery Backup to the ON
position. The “On A/C” LED light should illuminate.
NOTE: It takes approximately 18 hours to charge a new and fully depleted
battery at normal indoor temperature. If a power outage occurs before
the battery is fully charged, the battery-backup time shown on page
11 will be reduced. Therefore, you should not rely on battery-backup
power for at least 18 hours after your RG Battery Backup is initially
installed or a replacement battery is thereafter installed. During these
periods especially, and at all other times in general, you should ensure
that you have an alternative means of dialing 911, such as via a cellular
telephone. Your AT&T U-verseSM Voice service, including 911 dialing, will
not function without electrical or battery-backup power.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
t Turning off the RG Battery Backup
Turn switch to OFF position. The “On A/C” LED light should turn off.
t To Silence Audible Alarm
Turn mute switch to ON (down) position.
t To Conduct a Self-Test
Use the self-test to verify both the operation of the RG Battery Backup
and the condition of the battery. Turn the mute switch ON and OFF
(down and up), then ON and OFF (down and up) again within five seconds.
The RG Battery Backup automatically conducts a self-test every 21 days.
NOTE: The-self test may not be available for use if the battery voltage is
low (including the recharging period following a power failure or during
"On Battery" mode). This is normal. Wait until the battery fully recharges
before initiating a self-test.
During the self-test, the RG Battery Backup briefly operates on
battery-backup power. The “Testing Battery” LED will flash for five
minutes during the test period. If the RG Battery Backup passes the
self-test, it returns to online operation. If the RG Battery Backup fails the
self-test, it immediately returns to online operation and lights the
“Replace Battery” LED. The loads are not affected. Recharge the battery
overnight and perform the self-test again. If the “Replace Battery” LED is
still on, the battery needs to be replaced.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Battery Replacement Procedure
To order a replacement battery or for recycling information
The RG Battery Backup is designed with an easy-access battery door.
Replacement of the battery requires removing the battery door on the rear of
the device.
No tools are needed.
STEP 1:
Turn off power switch. Disconnect the RG Battery
Backup from power and any connected devices.
Remove the battery door on the rear of the RG Battery
Backup by pressing the tab on the top of the battery
door and pulling outward.
STEP 2:
Remove the battery from enclosure; remove the wire
connections from the battery.
STEP 3
Connect the new battery (black-to-black, red-to-red);
place the battery into enclosure.
WARNING: Carefully connect the wires to the correct
terminals. The replacement battery will have
color-coded terminals (red = +, black = -).
Do not misconnect the wires.
STEP 4:
Securely reconnect battery door.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Warranty
LIMITED THREE (3) YEAR WARRANTY
What this warranty covers.
Belkin International, Inc. warrants to the original AT&T U-VerseSM subscriber of this
Belkin Residential Gateway (RG) Battery Backup Unit (BBU), that the RG BBU shall be
free of defects in design, assembly, material, or workmanship.
What the period of coverage is.
Belkin International, Inc. warrants the Belkin RG BBU for three (3) years from the original
date of installation.
What will we do to correct problems?
RG BBU Warranty. Belkin will repair or replace, at its option, any defective RG BBU free
of charge (except for shipping charges for the RG BBU).
What is not covered by this warranty?
All above warranties are null and void if the Belkin RG BBU is not provided to Belkin
International, Inc. for inspection upon Belkin's request at the sole expense of the
purchaser, or if Belkin International, Inc. determines that the Belkin RG BBU has been
improperly installed, altered in any way or tampered with. The Belkin RG BBU Warranty
does not protect against acts of God (including but not limited to flood and earthquake),
war, vandalism, theft, normal-use wear and tear, erosion, depletion, obsolescence,
abuse, or alteration.
How to get service.
To get service for your Belkin RG BBU you must take the following steps:
1. Contact Belkin International, Inc. at 501 W. Walnut St., Compton CA 90220, Attn:
Customer Service, or call (866)-539-5791 Be prepared to provide the following
information: (a). The part number of the Belkin RG BBU. (b). When the RG BBU was
first installed. (c). Proof of AT&T U-VerseSM service installation.
2. Your Belkin Customer Service Representative will then instruct you on how to forward
your receipt and Belkin RG BBU and how to proceed with your claim.
Belkin International, Inc. reserves the right to review the damaged Belkin RG BBU. All
costs of shipping the Belkin RG BBU to Belkin International, Inc. for inspection shall be
borne solely by the purchaser. If Belkin determines, in its sole discretion, that it is
impractical to ship the damaged equipment to Belkin International, Inc., Belkin may
designate, in its sole discretion, an equipment repair facility to inspect and estimate the
cost to repair such equipment. The cost, if any, of shipping the equipment to and from
such repair facility and of such estimate shall be borne solely by the purchaser.
Damaged products must remain available for inspection until the claim is finalized.
Whenever claims are settled, Belkin International, Inc. reserves the right to be subro-
gated under any existing insurance policies the purchaser may have.
How state law relates to the warranty.
THIS WARRANTY CONTAINS THE SOLE WARRANTY OF BELKIN INTERNATIONAL,
INC., THERE ARE NO OTHER WARRANTIES, EXPRESSED OR, EXCEPT AS
REQUIRED BY LAW, IMPLIED, INCLUDING THE IMPLIED WARRANTY OR CONDI-
TION OF QUALITY, MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE, AND SUCH IMPLIED WARRANTIES, IF ANY, ARE LIMITED IN DURATION
TO THE TERM OF THIS WARRANTY. Some states do not allow limitations on how long
an implied warranty lasts, so the above limitations may not apply to you.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Specifications
Technical Specifications:
Input Voltage Range
Input Frequency
0 to 140VAC
50/60Hz
Nominal Output Voltage
Max Power
12VDC
36W
Alarms
Visual and Audible
Operating Temperature
32 to 113 degrees F (0 to 45 degrees C)
Battery (@ 77 degrees F, 25 degrees C):
Type/Rating
12V/7.2Ah sealed lead-acid battery
F6c127xBAT
Replacement Battery
Part Number
Typical Battery Recharge Time 18 hours for a new and fully depleted
battery at normal indoor temperature
Typical Backup Time
4 hours—With a new and fully charged
CSB- or YUASA-branded battery or
other battery recommended or supplied
by Belkin, with one corded single-line,
touchtone phone connected to the AT&T
U-verseSM Residential Gateway directly
or through your in-home wiring, and with
no other equipment and no service other
than AT&T U-verseSM Voice service drawing
power from the RG Battery Backup. Actual
results will vary, depending, among other
things, on battery age, usage patterns, and
environmental conditions.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
|