TUBE CONDENSER MICROPHONE T‑47  
a bathtub, washing machine, swimming pool,etc.). When doing voice  
recordings, always use the enclosed windscreen to protect the capsule  
from moisture.  
PSU‑T power supply:  
To reduce the risk of electric shock, do not remove the top cover (or the  
rear section). No user serviceable parts inside.  
Do not defeat the safety purpose of the polarized or grounding-type plug.  
You should only connect the T-47 to the provided power supply.  
Service and care:  
After each use, wipe the microphone down with a soft cloth and place it  
back into its protective casing (included with the microphone).  
3. Control elements and connections  
3.1 Microphone  
You can tell that the T-47 is switched on when the small window glows  
red.  
There is an XLR connector on the bottom end of the microphone. Connect  
it to the power supply (PSU-T).  
3.2 Power supply  
The included BEHRINGER PSU-T not only provides the supply volt-  
age for the tube preamplifier but also employs a circuit that reduces the  
low frequency response. This is activated on the front panel with the  
LOW CUT switch.  
3
Control elements and connections  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TUBE CONDENSER MICROPHONE T‑47  
The POWER switch on the unit's rear panel turns on the power supply.  
Here you also find the following:  
=
=
=
=
=
a seven-pin XLR connector to connect to the T-47 (MIC),  
a three-pin XLR connector to transmit the signal (OUTPUT),  
a switch to suppress signal humming noise (GND LIFT),  
an IEC power receptacle  
and a fuse holder.  
+
Use the provided cable to connect the T‑47 to the power sup‑  
ply unit!  
4. Set‑up  
Mounting the microphone  
The microphone comes with an elastic shockmount. The advantage to a  
conventional microphone stand mount is that mechanically induced noise  
is virtually absorbed.  
To mount the microphone, attach the shockmount to the microphone stand  
and, from above, slide the T-47 into the shockmount.  
Caution  
+
The provided shockmount is not intended to be used for sus-  
pending the T‑47!  
Alternatively, you can also mount the T-47 on a microphone stand mount.  
There is a screw adapter on the bottom side of the microphone.  
Warming up  
The T-47 can basically be used a couple of seconds after the PSU-T has  
been switched on. However, the typical sound of the the T-47 only unfolds  
a while after activating the power supply. We recommend allowing the  
microphone to “warm up” 30 minutes before use.  
Level setting / adjusting the basic sound  
Adjust the gain control in the microphone channel of your mixing console  
so that the peak LED lights up only occasionally or never at all. The EQ  
4
Set-up  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TUBE CONDENSER MICROPHONE T‑47  
controls in the microphone channel should be set to mid-travel position  
to start with; low-cut filter and signal level attenuation should be switched  
off. To get the sound you want, try changing the mic position relative to  
the sound source or even move the microphone around in the recording  
room of your studio. Adjusting the angle at which walls face the sound  
source can also be helpful. Only when the desired basic sound has been  
achieved, you should start to use equalizers and signal processors, if any  
at all. Remember: less is often more!  
5. Directivity  
Your T-47 features a capsule with a cardioid pickup pattern and is ideal  
for recording individual instruments, vocals and speech. Cardioid pickup  
pattern means that the sound produced by sources located in front of the  
mic is strongly picked up. It is often used in recording situations, since this  
directivity pattern tones down the pickup of sounds located to the back of  
the microphone.  
To place the microphone correctly, the BEHRINGER logo needs to face the  
sound source being recorded.  
6. Audio connection  
To transmit a preamplified signal (OUTPUT connector on the PSU-T),  
use a balanced microphone cable with the following pin assignment:  
pin 1 = shielding; pin 2 = +; pin 3 = -. Since your PSU-T features gold-plated  
contact points, we recommend that you use only microphone cables with  
gold-plated connectors.  
Fig. 6.1: XLR connectors  
7. Warranty  
Find our terms of warranty at http://www.behringer.com.  
5
Warranty  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TUBE CONDENSER MICROPHONE T‑47  
8. Specifications  
Transducer type  
Polar pattern  
condenser, 16 mm (0.63'')  
cardioid  
Preamplifier  
vacuum tube (12AX7)  
gold-plated balanced XLR connector  
-40 dBV (0 dBV = 1 V/Pa)  
20 Hz to 20 kHz  
Output (PSU-T)  
Open circuit sensitivity  
Frequency response  
Level attenuation  
Low-cut filter  
-
12 dB/oct. @ 100 Hz (switchable)  
130 dB  
Max. SPL (3 % THD @ 1 kHz)  
Dynamic range  
110 dB  
Nominal impedance  
Load impedance  
Supply voltage  
approx. 200 Ω  
>1 kΩ  
adapter BEHRINGER PSU-T  
MAinS voLTAge / FUSe  
100-120 V~, 50/60 Hz  
220-230 V~, 50/60 Hz  
Mains connector  
T 250 mA H 250 V  
T 125 mA H 250 V  
standard IEC receptacle  
Dimensions  
Æ shaft: 2.4", length: 8.5" (Æ  
shaft: 62 mm, length: 215 mm)  
Weight (net)  
approx. 1 lb. (approx. 0.47 kg)  
BEHRINGER is constantly striving to maintain the highest professional standards. As a result of these  
efforts, modifications may be made from time to time to existing products without prior notice. Specifica-  
tions and appearance may differ from those listed or illustrated.  
Technical specifications and appearance are subject to change without notice. The information contained  
herein is correct at the time of printing. BEHRINGER accepts no liability for any loss which may be  
suffered by any person who relies either wholly or in part upon any description, photograph or statement  
contained herein. Colors and specifications may vary slightly from product. Our products are sold through  
authorized dealers only. Distributors and dealers are not agents of BEHRINGER and have absolutely  
no authority to bind BEHRINGER by any express or implied undertaking or representation. This manual  
is copyrighted. No part of this manual may be reproduced or transmitted in any form or by any means,  
electronic or mechanical, including photocopying and recording of any kind, for any purpose, without  
the express written permission of BEHRINGER International GmbH.  
ALL RIGHTS RESERVED. © 2008 BEHRINGER International GmbH,  
Hanns-Martin-Schleyer-Str. 36-38, 47877 Willich-Muenchheide II, Germany. Tel. +49 2154 9206 0,  
Fax +49 2154 9206 4903  
6
Specifications  
Download from Www.Somanuals.com. All Manuals Search And Download.  

3Com Network Card 3CR990 User Manual
3M Tablet Accessory 29600 User Manual
6 948RE ML 135223 00G48 960RE ML 135224 00G60 User Manual
Acu Rite Clock DeIux wirelss weather station and atomic clock User Manual
Acu Rite Thermostat D1523 User Manual
Allied Telesis Webcam management software layer 2+ fast ethernet switches User Manual
Amana Range AGR5835QDW User Manual
American Standard Outdoor Shower T371 Series User Manual
ATN Binoculars Night Vision Biocular User Manual
BK Stereo Amplifier 7250 User Manual