Installation
Instructions
BERWICK™
7430.101
MONOBLOCK LAVATORY FAUCET with
Speed Connect™ Drain
Congratulations on purchasing your American Standard
faucet with Speed Connect drain, a feature found only on
American Standard faucets.
Speed Connect Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
Certified to comply with ANSI A112.18.1
M968641
*Your new American Standard faucet is designed to work only with the Speed Connect drain.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Recommended tools
Tubing Cutter
Screwdriver
Channel Locks
Adjustable Wrench
Turn off hot and cold water
supplies before beginning.
INSTALL FAUCET
CAUTION
1
Seat SEAL (1) into under side of ESCUTCHEON RING (2).
Seat ESCUTCHEON RING (2) with collar facing up into groove in
faucet base.
Feed FAUCET SUPPLIES (3), MOUNTING STUD (4) and DRAIN
CABLE ASSEMBLY (8) through ESCUTCHEON RING (2) and the
mounting hole of lavatory or mounting surface. Figure A.
Figure A
From below, push GASKET (7) and RETAINING WASHER (5) onto
MOUNTING STUD (4). Secure Faucet with MOUNTING NUT (6),
pulling faucet to front of sink, so SUPPLIES (3) rests against
mounting hole. Before final tightening, make sure collar on
MOUNTING NUT (6) is seated into RETAINING WASHER (5).
Figure B.
GROOVE
(FAUCET
BASE)
Adjust Faucet so that it is centered. Tighten MOUNTING NUT (6)
to complete faucet mounting.
2
1
4
MOUNTING
SURFACE
7
5
3
5
6
4
COLLAR ON
MOUNTING NUT
Figure B
8
1
Download from Www.Somanuals.com. All Manuals Search And Download.
ATTACH CABLE CONNECTOR
7
8
Fig. A.
Fig. B.
Thread CABLE CONNECTOR (1) clockwise
onto DRAIN BODY CONNECTION (2) and
hand tighten. Fig. A.
1
Your new POP-UP DRAIN installation is
now complete. Fig. B.
Note: Tailpeice on pop-up drain is 1-1/4” O.D.
Fig. B.
2
1-1/4” O.D.
CHECK OPERATION OF POP-UP
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and
closes.
Note: If STOPPER (2) does not open and close properly then refer
to the “troubleshooting section” of these instructions.
1
2
MAKE WATER SUPPLY AND WASTE CONNECTIONS
9
Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies.
Connection on fitting supplies are 3/8" compression. Connect
left SUPPLY (1) to Hot (Marked with a Red Band) and right supply
to COLD (2) wall supply.
Faucet supplies are 20" long from faucet base.
Note: If additional supply length is required, installer must
purchase additional parts separately.
Important: If SUPPLY HOSES (1, 2) are to long, loop as
illustrated to avoid kinking.
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to
waste outlet.
APPROX. 20"
2
BLUE
BAND
1
RED
BAND
3/8" COMPRESSION
COLD
HOT
M968641
3
Download from Www.Somanuals.com. All Manuals Search And Download.
ON
TEST INSTALLED FITTING
10
OFF
With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
COLD
1
HOT
Remove AERATOR (3).
Operate HANDLE (1) to flush water lines thoroughly.
Replace AERATOR (3).
3
4
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (4) and fill lavatory with water.
Check that DRAIN STOPPER (5) makes a good seal
and retains water in Sink. If DRAIN STOPPER (5)
does not seal properly, please refer to Troubleshooting
section in these instructions.
5
Release POP-UP KNOB (4) down and check all drain
connections and "P" trap for leaks.
if necessary.
Tighten
WASTE
OUTLET
2
“P” TRAP
2
2.5mm HEX KEY
Turn off hot and cold water
supplies before beginning.
SERVICE
CAUTION
11
3
4
1
To remove or replace cartidge
2
Turn valve to OFF position.
Pull out PLUG BUTTON (1) and remove HANDLE SCREW (2).
Pull off HANDLE (3) and CAP (4).
REMOVE
INSTALL
Unthread CARTRIDGE NUT (5) and remove.
Pull out CARTEIDGE (6).
Inspect CARTRIDGE (6) and O-RINGS (7) for debris and clean
if necessary.
5
Clean MANIFOLD (8) and rinse clean.
Reinstall CARTRIDGE (6) and O-RINGS (7) onto MANIFLOD (8).
Reinstall CARTRIDGE NUT (5), CAP (4) and HANDLE ASSEMBLY (3).
If spout drips, operate handle several times from OFF to ON and HOT to
COLD position. Do not force - handles turn only 90˚.
6
7
8
CARE INSTRUCTIONS:
12
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
M968641
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Speed Connect™ Drain
Troubleshooting Guide
If sink does not hold water even though Stopper is in the “down” position:
• Follow CABLE ADJUSTMENT PROCEDURE.
If Stopper does not raise up fully or sink drains too slowly:
• Follow CABLE ADJUSTMENT PROCEDURE.
If you need to remove the Stopper:
• Follow STOPPER REMOVAL PROCEDURE.
If you would like the ability to remove your Stopper simply by lifting it out of the drain:
• Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.
CABLE ADJUSTMENT PROCEDURE
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as
“Cam” in the illustration. Fig. B.
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the
Stopper should be in the UP position. Fig. B, C.
Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the
Drain Body Connection (2) and hand-tighten. Fig. A.
DOWN
Fig. A.
Fig. B. Fig. C.
CAM
1
RE-ATTACH
1
CAM CAP
STOPPER
DISCONNECT
2
STOPPER REMOVAL PROCEDURE
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled
as “Cam” and “Cam Cap” in the illustration. Fig. B.
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.
The Stopper can now be removed by lifting it out of the Drain. Fig. F.
Fig. F.
Fig. D.
Fig. E.
REMOVE
CAM
REMOVE
CAM CAP
M968641
5
Download from Www.Somanuals.com. All Manuals Search And Download.
STOPPER INSTALLATION PROCEDURE
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be
removed) or “Unlock” Mode (Stopper is removable).
Locked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. G.
Fig. G.
LOGO
To install the stopper in “Locked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the rear of the
Sink and the American Standard logo is facing front. Rotate
Stopper slightly if necessary so that the Stopper slides all the
way down.Fig. G.
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
LOOP TOWARD
REAR OF SINK
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
DRAIN
the Cam to make sure it is fully inserted. Fig. K.
Locked Mode
(Vandal Proof)
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
Troubling Shooting Guide to complete installation. Stopper will be
in “Locked” mode and not be removable.
Unlocked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. H.
Fig. H.
LOGO
To install the stopper in “Unlocked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the front of the
Sink and the American Standard logo is facing rear. Rotate Stopper
slightly if necessary so that the Stopper slides all the way down.
Fig. H.
180˚
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
LOOP TOWARD
FRONT OF SINK
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
DRAIN
Unlocked Mode
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
“Troublingshooting Guide” to complete installation. Stopper will be
in “Unlocked” mode and removable.
Fig. J.
Fig. K.
CAM
INSTALL CAM
INSTALL
CAM CAP
M968641
6
Download from Www.Somanuals.com. All Manuals Search And Download.
|