American Standard Plumbing Product M968641 User Manual

Installation  
Instructions  
BERWICK™  
7430.101  
MONOBLOCK LAVATORY FAUCET with  
Speed Connect™ Drain  
Congratulations on purchasing your American Standard  
faucet with Speed Connect drain, a feature found only on  
American Standard faucets.  
Speed Connect Drain*  
• Fewer parts, installs in less time  
• Never needs adjustment  
• Guaranteed to seal properly the first time, every time.  
Certified to comply with ANSI A112.18.1  
M968641  
*Your new American Standard faucet is designed to work only with the Speed Connect drain.  
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.  
Recommended tools  
Tubing Cutter  
Screwdriver  
Channel Locks  
Adjustable Wrench  
Turn off hot and cold water  
supplies before beginning.  
INSTALL FAUCET  
CAUTION  
1
Seat SEAL (1) into under side of ESCUTCHEON RING (2).  
Seat ESCUTCHEON RING (2) with collar facing up into groove in  
faucet base.  
Feed FAUCET SUPPLIES (3), MOUNTING STUD (4) and DRAIN  
CABLE ASSEMBLY (8) through ESCUTCHEON RING (2) and the  
mounting hole of lavatory or mounting surface. Figure A.  
Figure A  
From below, push GASKET (7) and RETAINING WASHER (5) onto  
MOUNTING STUD (4). Secure Faucet with MOUNTING NUT (6),  
pulling faucet to front of sink, so SUPPLIES (3) rests against  
mounting hole. Before final tightening, make sure collar on  
MOUNTING NUT (6) is seated into RETAINING WASHER (5).  
Figure B.  
GROOVE  
(FAUCET  
BASE)  
Adjust Faucet so that it is centered. Tighten MOUNTING NUT (6)  
to complete faucet mounting.  
2
1
4
MOUNTING  
SURFACE  
7
5
3
5
6
4
COLLAR ON  
MOUNTING NUT  
Figure B  
8
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATTACH CABLE CONNECTOR  
7
8
Fig. A.  
Fig. B.  
Thread CABLE CONNECTOR (1) clockwise  
onto DRAIN BODY CONNECTION (2) and  
hand tighten. Fig. A.  
1
Your new POP-UP DRAIN installation is  
now complete. Fig. B.  
Note: Tailpeice on pop-up drain is 1-1/4” O.D.  
Fig. B.  
2
1-1/4” O.D.  
CHECK OPERATION OF POP-UP  
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and  
closes.  
Note: If STOPPER (2) does not open and close properly then refer  
to the “troubleshooting section” of these instructions.  
1
2
MAKE WATER SUPPLY AND WASTE CONNECTIONS  
9
Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies.  
Connection on fitting supplies are 3/8" compression. Connect  
left SUPPLY (1) to Hot (Marked with a Red Band) and right supply  
to COLD (2) wall supply.  
Faucet supplies are 20" long from faucet base.  
Note: If additional supply length is required, installer must  
purchase additional parts separately.  
Important: If SUPPLY HOSES (1, 2) are to long, loop as  
illustrated to avoid kinking.  
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to  
waste outlet.  
APPROX. 20"  
2
BLUE  
BAND  
1
RED  
BAND  
3/8" COMPRESSION  
COLD  
HOT  
M968641  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
ON  
TEST INSTALLED FITTING  
10  
OFF  
With HANDLE (1) in OFF position, turn on WATER  
SUPPLIES (2) and check all connections for leaks.  
COLD  
1
HOT  
Remove AERATOR (3).  
Operate HANDLE (1) to flush water lines thoroughly.  
Replace AERATOR (3).  
3
4
CHECK DRAIN CONNECTIONS  
Operate POP-UP KNOB (4) and fill lavatory with water.  
Check that DRAIN STOPPER (5) makes a good seal  
and retains water in Sink. If DRAIN STOPPER (5)  
does not seal properly, please refer to Troubleshooting  
section in these instructions.  
5
Release POP-UP KNOB (4) down and check all drain  
connections and "P" trap for leaks.  
if necessary.  
Tighten  
WASTE  
OUTLET  
2
“P” TRAP  
2
2.5mm HEX KEY  
Turn off hot and cold water  
supplies before beginning.  
SERVICE  
CAUTION  
11  
3
4
1
To remove or replace cartidge  
2
Turn valve to OFF position.  
Pull out PLUG BUTTON (1) and remove HANDLE SCREW (2).  
Pull off HANDLE (3) and CAP (4).  
REMOVE  
INSTALL  
Unthread CARTRIDGE NUT (5) and remove.  
Pull out CARTEIDGE (6).  
Inspect CARTRIDGE (6) and O-RINGS (7) for debris and clean  
if necessary.  
5
Clean MANIFOLD (8) and rinse clean.  
Reinstall CARTRIDGE (6) and O-RINGS (7) onto MANIFLOD (8).  
Reinstall CARTRIDGE NUT (5), CAP (4) and HANDLE ASSEMBLY (3).  
If spout drips, operate handle several times from OFF to ON and HOT to  
COLD position. Do not force - handles turn only 90˚.  
6
7
8
CARE INSTRUCTIONS:  
12  
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.  
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A  
CLOTH WITH A COARSE SURFACE.  
M968641  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Speed Connect™ Drain  
Troubleshooting Guide  
If sink does not hold water even though Stopper is in the “down” position:  
• Follow CABLE ADJUSTMENT PROCEDURE.  
If Stopper does not raise up fully or sink drains too slowly:  
• Follow CABLE ADJUSTMENT PROCEDURE.  
If you need to remove the Stopper:  
• Follow STOPPER REMOVAL PROCEDURE.  
If you would like the ability to remove your Stopper simply by lifting it out of the drain:  
Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.  
CABLE ADJUSTMENT PROCEDURE  
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.  
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as  
“Cam” in the illustration. Fig. B.  
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the  
Stopper should be in the UP position. Fig. B, C.  
Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.  
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the  
Drain Body Connection (2) and hand-tighten. Fig. A.  
DOWN  
Fig. A.  
Fig. B. Fig. C.  
CAM  
1
RE-ATTACH  
1
CAM CAP  
STOPPER  
DISCONNECT  
2
STOPPER REMOVAL PROCEDURE  
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.  
Look at the area on the Drain Body where the Cable was attached and locate the component labeled  
as “Cam” and “Cam Cap” in the illustration. Fig. B.  
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.  
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.  
The Stopper can now be removed by lifting it out of the Drain. Fig. F.  
Fig. F.  
Fig. D.  
Fig. E.  
REMOVE  
CAM  
REMOVE  
CAM CAP  
M968641  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
STOPPER INSTALLATION PROCEDURE  
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be  
removed) or “Unlock” Mode (Stopper is removable).  
Locked Mode:  
Look at the Plastic Loop at the bottom of the Stopper and notice  
that the Loop is on one side of the Stopper. Fig. G.  
Fig. G.  
LOGO  
To install the stopper in “Locked” mode, insert the Stopper into  
the Drain so that the Plastic Loop is facing toward the rear of the  
Sink and the American Standard logo is facing front. Rotate  
Stopper slightly if necessary so that the Stopper slides all the  
way down.Fig. G.  
Re-install the Cam into the Drain, rotating the Cam if necessary  
to make sure it is fully inserted. Fig. J.  
LOOP TOWARD  
REAR OF SINK  
Re-install the Cam Cap, making sure the guide teeth are facing  
outward. If the Cam Cap does not “snap” into place, then rotate  
DRAIN  
the Cam to make sure it is fully inserted. Fig. K.  
Locked Mode  
(Vandal Proof)  
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in  
Troubling Shooting Guide to complete installation. Stopper will be  
in “Locked” mode and not be removable.  
Unlocked Mode:  
Look at the Plastic Loop at the bottom of the Stopper and notice  
that the Loop is on one side of the Stopper. Fig. H.  
Fig. H.  
LOGO  
To install the stopper in “Unlocked” mode, insert the Stopper into  
the Drain so that the Plastic Loop is facing toward the front of the  
Sink and the American Standard logo is facing rear. Rotate Stopper  
slightly if necessary so that the Stopper slides all the way down.  
Fig. H.  
180˚  
Re-install the Cam into the Drain, rotating the Cam if necessary  
to make sure it is fully inserted. Fig. J.  
LOOP TOWARD  
FRONT OF SINK  
Re-install the Cam Cap, making sure the guide teeth are facing  
outward. If the Cam Cap does not “snap” into place, then rotate  
the Cam to make sure it is fully inserted. Fig. K.  
DRAIN  
Unlocked Mode  
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in  
“Troublingshooting Guide” to complete installation. Stopper will be  
in “Unlocked” mode and removable.  
Fig. J.  
Fig. K.  
CAM  
INSTALL CAM  
INSTALL  
CAM CAP  
M968641  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  

Accton Technology Switch VM2524 User Manual
Adcom Stereo Amplifier GFA7807 User Manual
AEG Food Saver 8000024628 User Manual
AEG Washer L61270BI User Manual
Aiwa Headphones HP A092 User Manual
Alpine Radio CDE HD138BT CDE HD137BT User Manual
Amana Range W10130752B User Manual
American Standard Hot Tub ANSI Z 12412 User Manual
Behringer Car Amplifier EP2000 User Manual
Beko Air Conditioner LG BKE 6450 D LG BKE 6500 D User Manual