Installation
Instructions
™
2064.400
SERIN
Bidet Faucet and Transfer Valve with
Speed Connect™ Drain
Congratulations on purchasing your American Standard
faucet with Speed Connect drain, a feature found only on
American Standard faucets.
Certified to comply with ANSI A112.18.1
M968924 Rev.1.3
Speed Connect Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
*Your new American Standard faucet is designed to work only with the Speed Connect drain.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Recommended tools
Roughing-in
8 TO 12
FINISHED
WALL
TRANSFER VALVE
Dimensions
(FOR FLUSHING
RIM OR SPRAY)
BIDET OUTLINE
IS SYMBOLIC
2-1/4
DIA.
(C)
(H)
7/8 DIA.
Plumbers' Putty or
Caulking
Screwdriver
1-3/16
DIA.
DOUCHE
SPRAY
2-1/8
DIA.
4-1/4
ADJ. 1-1/4
TO 2-1/4
1-1/4
MAX.
Phillips Screwdriver
1-3/8
DIA.
FOR GROUND JOINT
CONNECTION OR 1/2 "
O.D. SLIP (INLETS)
Channel Locks
Tubing Cutter
3-7/8
REAR VIEW WITH
WALL REMOVED
FINISHED
FLOOR
5-1/2
Adjustable Wrench
1-1/4 O.D. TAILPIECE
Turn off hot and cold water
supplies before beginning.
BIDET FAUCET INSTALLATION CAUTION
1
2
6
7
Place RUBBER RING (10) into ESCUTCHEON (4).
Install LOCKNUT (1) and RUBBER WASHER (2) onto VALVE BODIES (3, 3a). From
under side of mounting surface, install VALVE BODY (3, 3a) through valve mounting
holes. Threads of VALVE BODY (3, 3a) should extent at least 5/16 of a inch above
mounting surface top. Fig. A. Thread ESCUTCHEON (4) onto VALVE BODIES
(3, 3a) until snug against internal stop. If necessary, adjust LOCKNUT (1).
4
BIDET
LEDGE
10
8
Tighten LOCKNUTS (1) with WRENCH (5) (supplied)
to secure VALVE BODIES (3, 3a).
4
10
Fig. A.
Remove ESCUTCHEON (6), WASHER (7) and
UPPER GASKET (8) from TRANSFER VALVE (9).
Insert TRANSFER VALVE (9) into the center forward
hole of BIDET.
3a
5/16''
MIN.
MOUNTING
SURFACE
3
COLD
2
1
HOT
9
2
1
Replace UPPER GASKET (8) and WASHER (7) and
ESCUTCHEON (6) until it locks against internal stop.
Position the side threaded outlet rearward and
secure MOUNTING NUT (11).
11
5
3, 3a
2
8
7
9
1
SPRAY INSTALLATION
PUTTY
Assemble SPRAY BODY (1) to BIDET. Using putty, seal underside
of SPRAY BODY FLANGE (2) and secure with NUT (3).
6
3
Thread SPRAY HOSE (4) with SEAL WASHER (5) to SPRAY BODY (1).
Connect other end of HOSE (4) with SEAL WASHER (6) to side outlet
NIPPLE (7) of the TRANSFER VALVE (8).
5
4
4
Thread SPRAY CAP (9) onto SPRAY BODY (1).
Download from Www.Somanuals.com. All Manuals Search And Download.
ATTACH CABLE
CONNECTOR
8
9
Fig. A.
Fig. B.
Fig. C.
DOWN
POP-UP KNOB (1) must be fully
down. Fig. A.
1
Thread CABLE CONNECTOR (1)
clockwise onto DRAIN BODY
CONNECTION (2) and hand
tighten. Fig. B.
Your new POP-UP DRAIN
installation is now complete.
Fig. C.
2
1-1/4” O.D.
Note: Tailpeice on pop-up drain
is 1-1/4” O.D. Fig. C.
CHECK OPERATION OF POP-UP
5
4
Operate LIFT KNOB (1) to verify that STOPPER (2)
opens and closes.
1
3
1
Note: If STOPPER (2) does not open and close properly
then refer to the “troubleshooting section” of these
instructions.
2
INSTALL DIVERTER KNOB
2
Push DIVERTER KNOB (1) onto HANDLE ADAPTER (2).
Push on RING (3) and tighten with SCREW (4).
Press on KNOB CAP (5).
Note: Screwdriver gap is for disassembling and should
point downwards.
OUTLINE OF BIDET
TEE AND HOSE CONNECTION
10
Insert SEAL (1) into ADAPTER (2) and tighten ADAPTER (2) to
side of TRANSFER VALVE (3).
5
6
6
3
Install SEAL (4) into coupling nut of TEE (5) and tighten
connection to ADAPTER (2).
7a
Connect HOSE COUPLING NUTS (6) to Hot and Cold valve
bodies and securely tighten.
COUPLING
NUT
4
2
1
Front
9
7
3/8 O.D.
BULL-NOSE
RISERS
1/2" PIPE
THREAD
WATER SUPPLY CONNECTION
COMPRESSION
NUT
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS NOT
INCLUDED AND MUST BE PURCHASED SEPARATELY.
2
FLEXIBLE
SUPPLIES
Connect water supply to VALVE BODIES (7,7a) with
FERRULE
1/2" IPS FLEXIBLE SUPPLIES (8) or 3/8" O.D. BULL-NOSE
RISERS (9). Use adjustable wrench to tighten connections.
Do not over tighten. Be careful not to kink copper supply when
bending. Use tubing cutter to cut to proper length.
COLD
Connect HOT water supply to inlet of left SHANK and COLD
water supply to right SHANK using sealant, appropriate
connectors, and COUPLING NUTS.
CONNECT TO
WASTE OUTLET
3/8 COMPRESSION
CONNECTION
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to
waste outlet.
HOT
M968924 Rev.1.3
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALL HANDLES
11
Push ADAPTER (1) on VALVE STEM (2), so that the hole of the
ADAPTER (1) without a spline is facing up. See figure "A". Tighten
STEM SCREW (3) to secure ADAPTER (1).
THREAD ON
TO DECK
ADAPTER
4
Find correct position of LEVER HANDLE ASSEMBLY (4) by adjusting
male teeth on ADAPTER (1) to female teeth in HANDLE (4).
TOP
Thread LEVER HANDLE ASSEMBLY (4) onto ESCUTCHEON (5)
until snug against mounting surface.
1
3
2
Figure "A"
SPLINE END DOWN
5
TEST INSTALLED FITTING
12
OUTLINE OF BIDET
With HANDLES (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
1
3
Operate both HANDLES (1) to flush water
lines thoroughly.
1
Rotate TRANSFER VALVE (5) from rim wash to
spray several times to check operation.
CHECK DRAIN CONNECTIONS
13
Pull up POP-UP KNOB (3) and fill Bidet with water. Check
that DRAIN STOPPER (4) makes a good seal and retains
water in Bidet. If STOPPER (4) does not seal properly,
4
2
please refer to “Troubleshooting Guide” in these instructions.
SPRAY
Push POP-UP KNOB (3) down and check all drain
connections and "P" trap for leaks.
if necessary.
Tighten
2
SERVICE
CARE INSTRUCTIONS:
14
15
To change direction of handle rotation,
proceed as follows:
Turn valve to OFF position.
Thread counter-clock wise HANDLE BASE (1) to remove
HANDLE ASSEMBLY (2) from ESCUTCHEON BASE (3).
Use a flat blade screw driver to remove SPRING CLIP (4).
Lift STOP WASHER (5), turn 90˚ and replace.
Replace SPRING CLIP (4).
DO: SIMPLY RINSE THE PRODUCT
CLEAN WITH CLEAR WATER. DRY
WITH A SOFT COTTON FLANNEL
CLOTH.
UNTHREAD
2
1
DO NOT: DO NOT CLEAN THE
PRODUCT WITH SOAPS, ACID,
POLISH, ABRASIVES, HARSH
CLEANERS, OR A CLOTH WITH
A COARSE SURFACE.
VALVE
90˚
5
3
Reinstall HANDLE ASSEMBLY (2).
4
If spout drips, operate handles several times from OFF
to ON position. Do not force - handles turn only 90˚.
M968924 Rev.1.3
Download from Www.Somanuals.com. All Manuals Search And Download.
Speed Connect™ Drain
Troubleshooting Guide
If sink does not hold water even though Stopper is in the “down” position:
• Follow CABLE ADJUSTMENT PROCEDURE.
If Stopper does not raise up fully or sink drains too slowly:
• Follow CABLE ADJUSTMENT PROCEDURE.
If you need to remove the Stopper:
• Follow STOPPER REMOVAL PROCEDURE.
If you would like the ability to remove your Stopper simply by lifting it out of the drain:
• Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.
CABLE ADJUSTMENT PROCEDURE
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as
“Cam” in the illustration. Fig. B.
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the
Stopper should be in the UP position. Fig. B, C.
Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the
Drain Body Connection (2) and hand-tighten. Fig. A.
DOWN
Fig. A.
Fig. B. Fig. C.
CAM
1
1
RE-ATTACH
CAM CAP
STOPPER
DISCONNECT
2
STOPPER REMOVAL PROCEDURE
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled
as “Cam” and “Cam Cap” in the illustration. Fig. B.
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.
The Stopper can now be removed by lifting it out of the Drain. Fig. F.
Fig. F.
Fig. D.
Fig. E.
REMOVE
CAM
REMOVE
CAM CAP
M968924 Rev.1.3
Download from Www.Somanuals.com. All Manuals Search And Download.
STOPPER INSTALLATION PROCEDURE
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be
removed) or “Unlock” Mode (Stopper is removable).
Locked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. G.
Fig. G.
To install the stopper in “Locked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the rear of the
LOGO
Sink and the American Standard logo is facing front. Rotate
Stopper slightly if necessary so that the Stopper slides all the
way down.Fig. G.
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
LOOP TOWARD
REAR OF BIDET
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
DRAIN
Locked Mode
(Vandal Proof)
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
Troubling Shooting Guide to complete installation. Stopper will be
in “Locked” mode and not be removable.
Unlocked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. H.
Fig. H.
To install the stopper in “Unlocked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the front of the
Sink and the American Standard logo is facing rear. Rotate Stopper
slightly if necessary so that the Stopper slides all the way down.
Fig. H.
LOGO
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
180˚
LOOP TOWARD
FRONT OF BIDET
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
DRAIN
Unlocked Mode
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
“Troublingshooting Guide” to complete installation. Stopper will be
in “Unlocked” mode and removable.
Fig. J.
Fig. K.
CAM
INSTALL CAM
INSTALL
CAM CAP
M968924 Rev.1.3
Download from Www.Somanuals.com. All Manuals Search And Download.
™
SERIN
BIDET FITTING
MODEL NUMBERS
2064.400
M962508-YYY0A
POP-UP ROD
M950245-YYY0A
HANDLE ASSEMBLY
M962414-YYY0A
ESCUTCHEON KIT
918428-0070A
HANDLE SCREW
M962481-YYY0A
LIFT ROD GUIDE
M962182-YYYOA
HANDLE
918555-0070A
HANDLE SCREW
918049-0070A
ADAPTER
033772-0070A
TEE AND HOSE KIT
(INCLUDING SEALS)
923348-0070A
HANDLE ADAPTER
994053-0070A
CARTRIDGE
030257-YYYOA
ESCUTCHEON KIT
M961634-0070A
VALVE MTG. KIT
030281-0070A
TRANSFER VALVE
MOUNTING KIT
060463-0070A
ADAPTER KIT
953800-0070A
TRANSFER VALVE
024220-0070A
COUPLING NUT
M962544-YYY0A
STOPPER
ASSEMBLY
Replace the "YYY" with
appropriate finish code
M952430-0070A
CABLE ASSEMBLY
028645-YYY0A
CHROME
002
295
BIDET SPRAY
SATIN NICKEL
M962457-007A
FLANGE
ASSEMBLY
M922872-0070A
CAM SEAT INSERT
028646-0070A
SPRAY HOSE
CONNECTION KIT
M962552-0070A
CAM ASSEMBLY
M952426-YYY0A
DRAIN ASSEMBLY
M962458-0070A
DRAIN MOUNTING KIT
M913207-0070A
TAILPIECE INSERT
M962463-0020A
TAILPIECE & ESCUTCHEON
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1 (800) 442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-12-00
Product names listed herein are trademarks of American Standard Inc.
© AS America, Inc. 2008
M968924 Rev.1.3
Download from Www.Somanuals.com. All Manuals Search And Download.
|