American Standard Bathroom Aids 7005201 User Manual

Installation  
Instructions  
COPELAND  
Centerset Lavatory Faucet  
with Speed Connect™ Drain  
7005.201  
Congratulations on purchasing your American Standard  
faucet with Speed Connect drain, a feature found only on  
American Standard faucets.  
Speed Connect Drain*  
• Fewer parts, installs in less time  
• Never needs adjustment  
• Guaranteed to seal properly the !rst time, every time.  
Certified to comply with ANSI A112.18.1  
*Your new American Standard faucet is designed to work only with the Speed Connect drain.  
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.  
M968635 REV.1.1  
Recommended tools  
Tubing Cutter  
Screwdriver  
Channel Locks  
Adjustable Wrench  
Turn off hot and cold water  
supplies before beginning.  
INSTALL FAUCET  
CAUTION  
1
Insert FAUCET (1) and CABLE CONNECTOR (2) through  
mounting holes of Sink or Mounting Surface. Fig. A.  
Fig. A.  
Assemble LOCKNUTS (3) onto SHANKS (4) from under  
side of Sink. Hand tighten firmly. Fig. B.  
(HAND TIGHTEN)  
1
4
3
POP-UP  
CABLE  
4
Fig. B.  
SINK OR  
MOUNTING  
SURFACE  
3
2
2
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATTACH CABLE CONNECTOR  
7
8
Fig. A.  
Fig. B.  
Thread CABLE CONNECTOR (1) clockwise  
onto DRAIN BODY CONNECTION (2) and  
hand tighten. Fig. A.  
1
Your new POP-UP DRAIN installation is  
now complete. Fig. B.  
Note: Tailpeice on pop-up drain is 1-1/4” O.D.  
Fig. B.  
2
1-1/4” O.D.  
CHECK OPERATION OF POP-UP  
1
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and  
closes.  
Note: If STOPPER (2) does not open and close properly then refer  
to the “troubleshooting section” of these instructions.  
2
MAKE WATER SUPPLY AND WASTE CONNECTIONS  
9
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS MUST BE  
PURCHASED SEPARATELY.  
Connect water supply to FAUCET (1) with 1/2" IPS FLEXIBLE  
SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3).  
Use adjustable wrench to tighten connections. Do not over tighten.  
Be careful not to kink copper supply when bending. Use tubing  
cutter to cut to proper length.  
1/2" PIPE  
THREAD  
1
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to  
waste outlet.  
COUPLING  
NUT  
2
FLEXIBLE  
SUPPLIES  
3
3/8 O.D.  
BULL-NOSE  
RISERS  
3/8” COMPRESSION  
CONNECTION  
COMPRESSION  
NUT  
FERRULE  
HOT  
COLD  
M968635 REV.1.1  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
TEST INSTALLED FITTING  
10  
With HANDLES (1) in OFF position, turn on WATER  
SUPPLIES (2) and check all connections for leaks.  
Remove AERATOR (3).  
4
Operate both HANDLES (1) to flush water lines thoroughly.  
1
Replace AERATOR (3).  
1
CHECK DRAIN CONNECTIONS  
Operate POP-UP KNOB (4) and fill lavatory with water.  
Check that DRAIN STOPPER (5) makes a good seal  
and retains water in SINK. If DRAIN STOPPER (5)  
does not seal properly, please refer to Troubleshooting  
section in these instructions.  
3
Release POP-UP KNOB (4) down and check all drain  
connections and "P" trap for leaks.  
if necessary.  
Tighten  
5
WASTE  
OUTLET  
2
2
“P” TRAP  
SERVICE  
11  
To change direction of handle:  
Turn valve to OFF position  
Remove SET SCREW (6) with 5/64" Hex Wrench.  
Pull HANDLE (1) “UP” firmly to release from ADAPTER (2).  
Pull HANDLE BASE (7) off of CARTRIDGE (8).  
1
6
Remove ADAPTER SCREW (3) from ADAPTOR (2).  
Pull off ADAPTER (2).  
7
3
90˚  
Remove SPRING CLIP (4). Lift STOP WASHER (5),  
turn 90˚ and replace. Replace SPRING CLIP (4).  
5
2
8
4
Replace ADAPTER (2) and ADAPTER SCREW (3).  
Find correct position of HANDLE ASSEMBLY (1)  
by adjusting male teeth on ADAPTER (2) to female  
teeth in HANDLE ASSEMBLY (1).  
Push HANDLE (1) down onto ADAPTER (4) until it  
snaps into place.  
CARE INSTRUCTIONS:  
12  
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.  
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A  
CLOTH WITH A COARSE SURFACE.  
M968635 REV.1.1  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Speed Connect™ Drain  
Troubleshooting Guide  
If sink does not hold water even though Stopper is in the “down” position:  
• Follow CABLE ADJUSTMENT PROCEDURE.  
If Stopper does not raise up fully or sink drains too slowly:  
• Follow CABLE ADJUSTMENT PROCEDURE.  
If you need to remove the Stopper:  
• Follow STOPPER REMOVAL PROCEDURE.  
If you would like the ability to remove your Stopper simply by lifting it out of the drain:  
Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.  
CABLE ADJUSTMENT PROCEDURE  
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.  
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as  
“Cam” in the illustration. Fig. B.  
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the  
Stopper should be in the UP position. Fig. B, C.  
Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.  
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the  
Drain Body Connection (2) and hand-tighten. Fig. A.  
DOWN  
Fig. A.  
Fig. B. Fig. C.  
CAM  
1
LIFT-KNOB  
RE-ATTACH  
STOPPER  
CAM CAP  
DISCONNECT  
2
STOPPER REMOVAL PROCEDURE  
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.  
Look at the area on the Drain Body where the Cable was attached and locate the component labeled  
as “Cam” and “Cam Cap” in the illustration. Fig. B.  
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.  
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.  
The Stopper can now be removed by lifting it out of the Drain. Fig. F.  
Fig. D.  
Fig. E.  
Fig. F.  
REMOVE  
CAM  
REMOVE  
CAM CAP  
M968635 REV.1.1  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
STOPPER INSTALLATION PROCEDURE  
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be  
removed) or “Unlock” Mode (Stopper is removable).  
Locked Mode:  
Look at the Plastic Loop at the bottom of the Stopper and notice  
that the Loop is on one side of the Stopper. Fig. G.  
Fig. G.  
LOGO  
To install the stopper in “Locked” mode, insert the Stopper into  
the Drain so that the Plastic Loop is facing toward the rear of the  
Sink and the American Standard logo is facing front. Rotate  
Stopper slightly if necessary so that the Stopper slides all the  
way down.Fig. G.  
Re-install the Cam into the Drain, rotating the Cam if necessary  
to make sure it is fully inserted. Fig. J.  
LOOP TOWARD  
REAR OF SINK  
Re-install the Cam Cap, making sure the guide teeth are facing  
outward. If the Cam Cap does not “snap” into place, then rotate  
the Cam to make sure it is fully inserted. Fig. K.  
DRAIN  
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in  
Troubling Shooting Guide to complete installation. Stopper will be  
in “Locked” mode and not be removable.  
Locked Mode  
(Vandal Proof)  
Unlocked Mode:  
Look at the Plastic Loop at the bottom of the Stopper and notice  
that the Loop is on one side of the Stopper. Fig. H.  
Fig. H.  
To install the stopper in “Unlocked” mode, insert the Stopper into  
the Drain so that the Plastic Loop is facing toward the front of the  
Sink and the American Standard logo is facing rear. Rotate Stopper  
slightly if necessary so that the Stopper slides all the way down.  
Fig. H.  
LOGO  
180˚  
Re-install the Cam into the Drain, rotating the Cam if necessary  
to make sure it is fully inserted. Fig. J.  
LOOP TOWARD  
FRONT OF SINK  
Re-install the Cam Cap, making sure the guide teeth are facing  
outward. If the Cam Cap does not “snap” into place, then rotate  
the Cam to make sure it is fully inserted. Fig. K.  
DRAIN  
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in  
“Troublingshooting Guide” to complete installation. Stopper will be  
in “Unlocked” mode and removable.  
Unlocked Mode  
Fig. J.  
Fig. K.  
CAM  
INSTALL CAM  
INSTALL  
CAM CAP  
M968635 REV.1.1  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  

Acer Mouse LZ20400161 User Manual
Addonics Technologies Computer Drive ZESAES256 User Manual
Alcatel Lucent Switch 1643 AMS User Manual
Alvarez Car Speaker S215 User Manual
AMX Network Card NXR ZGW ZRP User Manual
Audiovox Stereo System FD 250 User Manual
Axion Lawn Mower CZT2142 User Manual
Banner Power Supply MPS 15 User Manual
Behringer Musical Instrument 02222FX User Manual
Eureka Tents Tent K2 XT User Manual