AD-1 2 0 ES
In st allat ion / Operat or’s Man u al
(Ext en ded Side Pan els)
WARNING: For your safety the
AVERTISSEMENT: Assurez-vous de bien
suivre les instructions données dans cette
notice pour réduire au minimum le risque
d’incendie ou d’explosion ou pour éviter tout
dommage matériel, toute blessure ou la mort.
information in this manual must be
followed to minimize the risk of fire or
explosion or to prevent property damage,
personal injury or death.
Do not store or use gasoline or other flammable
vapor and liquids in the vicinity of this or any
other appliance.
Ne pas entreposer ni utiliser d’essence ni
d’autres vapeurs ou liquides inflammables dans
le voisinage de cet appareil ou de tout autre
appareil.
WHAT DO YOU DO IF YOU SMELL GAS
QUE FAIRE SI VOUS SENTEZ UNE ODEUR
DE GAZ:
* Do not try to light any appliance.
* Do not touch any electrical switch; do not use
any phone in your building.
* Clear the room, building or area of all
occupants.
* Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
* If you cannot reach your gas supplier, call the
fire department.
* Ne pas tenter d’allumer d’appareil.
* Ne touchez à aucun interrupteur. Ne pas
vous servir des téléphones se trouvant dans
le bâtiment où vous vous trouvez..
* Évacuez la pièce, le bâtiment ou la zone.
* Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions
du fournisseur.
* Si vous ne pouvez rejoindre le fournisseur
de gaz, appelez le service des incendies.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
L’installation et l’entretien doivent être assurés
par un installateur ou un service d’entretien
qualifié ou par le fournisseur de gaz.
For replacement parts, contact the distributor from which the dryer
was purchased or
American Dryer Corporation
88 Currant Road
Fall River MA 02720-4781
Telephone: (508) 678-9000 / Fax: (508) 678-9447
E-mail: [email protected]
070395
ADC Part No. 112185
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT
YOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPLY and THE GAS
SUPPLY or THE STEAM SUPPLY BEFORE ANY COVERS or GUARDS ARE
REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING, ADJUST-
ING, INSTALLATION, or TESTING OF ANY EQUIPMENT per OSHA (Occupational
Safety and Health Administration) STANDARDS.
«Attention: Lor des opérations d’entretien
des commandes étiqueter tous fils avant
de les déconnecter. Toute erreur de
câblage peut étre une source de danger et
de panne.»
“Caution: Label all wires prior to
disconnection when servicing controls. Wiring
errors can cause improper operation.”
CAUTION
DRYERS SHOULD NEVER BE LEFT UNATTENDED WHILE IN OPERATION.
WARNING
CHILDREN SHOULD NOT BE ALLOWED TO PLAY ON OR NEAR THE DRYER(S).
CHILDREN SHOULD BE SUPERVISED IF NEAR DRYERS IN OPERATION.
FOR YOUR SAFETY
DO NOT DRY MOP HEADS IN THE DRYER.
DO NOT USE DRYER IN THE PRESENCE OF DRY CLEANING FUMES.
WARNING
UNDER NO CIRCUMSTANCES should the door switch or the heat circuit devices
ever be disabled.
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNING
The dryer must never be operated with any of the back guards, outer tops, or service
panels removed. PERSONAL INJURY or FIRE COULD RESULT.
WARNING
DRYER MUST NEVER BE OPERATED WITHOUT THE LINT FILTER/SCREEN IN
PLACE, EVEN IF AN EXTERNAL LINT COLLECTION SYSTEM IS USED.
IMPORTANT
PLEASE OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment and/or
specified in the installation and operator's manual included with the dryer.
Dryers must not be installed or stored in an area where it will be exposed to water or weather.
The wiring diagram for the dryer is located in the front electrical control box area.
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
SECTION I
IMPORTANT INFORMATION
A. RECEIVING and HANDLING ...................................................................................................................................................... 2
B. SAFETY PRECAUTIONS .............................................................................................................................................................. 3
SECTION II
SUPER AD-30 SPECIFICATIONS
A. SPECIFICATIONS (Gas and Steam Models) .............................................................................................................................. 5
B. COMPONENT IDENTIFICATION ............................................................................................................................................... 7
SECTION III
INSTALLATION PROCEDURES
A. LOCATION REQUIREMENTS .................................................................................................................................................... 9
B. UNPACKING/SETTING UP .........................................................................................................................................................10
C. DRYER ENCLOSURE REQUIREMENTS ...............................................................................................................................12
D. FRESH AIR SUPPLY ....................................................................................................................................................................13
E. EXHAUST REQUIREMENTS ....................................................................................................................................................14
F. ELECTRICAL INFORMATION .................................................................................................................................................21
G. GAS INFORMATION ...................................................................................................................................................................27
H. STEAM INFORMATION .............................................................................................................................................................31
I. PREPARATION FOR OPERATION / START-UP .....................................................................................................................35
J. PREOPERATIONAL TESTS .......................................................................................................................................................36
K. OPERATING INSTRUCTIONS ...................................................................................................................................................39
L. SHUT DOWN INSTRUCTIONS ..................................................................................................................................................40
SECTION IV
SERVICE / PARTS INFORMATION
A. SERVICE ........................................................................................................................................................................................41
B. PARTS .............................................................................................................................................................................................41
SECTION V
WARRANTY INFORMATION
A. RETURNING WARRANTY CARD(S) ......................................................................................................................................42
B. WARRANTY ..................................................................................................................................................................................42
C. RETURNING WARRANTY PART(S) ........................................................................................................................................42
SECTION VI
ROUTINE MAINTENANCE
A. CLEANING ....................................................................................................................................................................................44
B. ADJUSTMENTS ............................................................................................................................................................................46
C. LUBRICATION .............................................................................................................................................................................46
SECTION VII
TROUBLESHOOTING...................................................................................................................... 47
SECTION VIII
REVERSING TIMER SPIN / DWELL ADJUSTMENTS.................................................................. 58
SECTION X
PROCEDURE FOR FUNCTIONAL CHECK OF REPLACEMENT COMPONENTS.................. 59
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION I
IMPORTANT INFORMATION
A. RECEIVING and HANDLING
The dryer is shipped in a protective stretch wrap cover with protective cardboard corners and top cover
(or optional box) as a means of preventing damage in transit. Upon delivery, the dryer and/or packaging, and
wooden skid should be visually inspected for shipping damage. If any damage whatsoever is noticed, inspect
further before delivering carrier leaves.
Dryers damaged in shipment:
1. ALL dryers should be inspected upon receipt and before they are signed for.
2. If there is suspected damage or actual damage, the trucker's receipt should be so noted.
3. If the dryer is damaged beyond repair, it should be refused. Those dryers which were not damaged in a
damaged shipment should be accepted, but the number received and the number refused must be noted
on the receipt.
4. If you determine that the dryer was damaged after the trucker has left your location, you should call the
delivering carrier's freight terminal immediately and file a claim. The freight company considers this
concealed damage. This type of freight claim is very difficult to get paid and becomes extremely difficult
when more than a day or two passes after the freight was delivered. It is your responsibility to file freight
claims. Dryer/parts damaged in transit cannot be claimed under warranty.
5. Freight claims are the responsibility of the consignee, and ALL claims must be filed at the receiving end.
ADC assumes no responsibility for freight claims or damages.
6. If you need assistance in handling the situation, please contact the ADC Traffic Manager at
(508) 678-9000.
IMPORTANT: The dryer must be transported and handled in an upright position at all times.
2
Download from Www.Somanuals.com. All Manuals Search And Download.
B. SAFETY PRECAUTIONS
WARNING: For your safety, the information in this manual must be followed to minimize
the risk of fire or explosion or to prevent property damage, personal injury, or
loss of life.
WARNING: The dryer must never be operated with any of the back guards, outer tops,
or service panels removed. PERSONAL INJURY or FIRE COULD
RESULT.
1. DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
2. Purchaser/user should consult the local gas supplier for proper instructions to be followed in the event
the user smells gas. The instructions should be posted in a prominent location.
3. WHAT TO DO IF YOU SMELL GAS..
a. DO NOT try to light any appliance.
b. DO NOT touch any electrical switch.
c. DO NOT use any phone in your building.
d. Clear the room, building, or area of ALL occupants.
e. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
f. If you cannot reach your gas supplier, call the fire department.
4. Installation and service must be performed by a qualified installer, service agency, or gas supplier.
5. Dryer(s) must be exhausted to the outdoors.
6. Although ADC produces a very versatile machine, there are some articles that, due to fabric composition
or cleaning method, should not be dried in it.
WARNING: Dry only water-washed fabrics. DO NOT dry articles spotted or washed in dry
cleaning solvents, a combustible detergent, or "all purpose" cleaner.
EXPLOSION COULD RESULT.
WARNING: DO NOT dry rags or articles coated or contaminated with gasoline, kerosene,
oil, paint, wax. EXPLOSION COULD RESULT.
WARNING: DO NOT dry mop heads. Contamination by wax or flammable solvents will
create a fire hazard.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNING: DO NOT use heat for drying articles that contain plastic, foam, sponge rubber,
or similarly textured rubber materials. Drying in a heated basket (tumbler) may
damage plastics or rubber and also may be a fire hazard.
7. A program should be established for the inspection and cleaning of lint in the heating unit area, exhaust
duct work, and inside the dryer. The frequency of inspection and cleaning can best be determined from
experience at each location.
WARNING: The collection of lint in the burner area and exhaust duct work can create a
potential fire hazard.
8. For personal safety, the dryer must be electrically grounded in accordance with local codes and/or the
National Electric Code ANSI/NFPA NO. 70-LATEST EDITION, or in CANADA, the Canadian
Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.
NOTE: Failure to do so will VOID THE WARRANTY.
9. UNDER NO CIRCUMSTANCES should the dryer door switches, lint door switch, heat safety circuit
ever be disabled.
WARNING: PERSONAL INJURY or FIRE COULD RESULT.
10. This dryer is not to be used in the presence of dry cleaning solvents or fumes.
11. Remove articles from the dryer as soon as the drying cycle has been completed.
WARNING: Articles left in the dryer after the drying and cooling cycles have been completed
can create a fire hazard.
12. DO NOT operate steam dryers with more than 125 PSI steam pressure. Excessive steam pressure can
damage steam coil and/or harm personnel.
13. Replace leaking flexible hoses or other steam fixtures immediately. DO NOT operate the dryer with
leaking flexible hoses. PERSONAL INJURY MAY RESULT.
14. READ and FOLLOW ALL CAUTION and DIRECTION LABELS ATTACHED TO THE DRYER.
WARNING: YOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPLY
and THE GAS SUPPLY BEFORE ANY COVERS or GUARDS ARE
REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR
CLEANING, ADJUSTING, INSTALLATION, or TESTING OF ANY
EQUIPMENT per OSHA (Occupational Safety and Health Administration)
STANDARDS.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION II
SPECIFICATIONS / COMPONENT IDENTIFICATION
A. SPECIFICATIONS
MAXIMUM CAPACITY (dry weight)
BASKET (tumbler) DIAMETER
BASKET (tumbler) DEPTH
BASKET MOTOR
120 lbs.
44-1/2"
42-1/2"
3/4 HP
3 HP
54.4 kg
113 cm
107.9 cm
.560 kw
2.238 kw
79.7 cm
BLOWER MOTOR
DOOR OPENING (Diameter)
BASKET VOLUME
31-3/8"
38.2 cu. ft.
1.08 cu.m.
DRYERS PER 20" / 40" TRUCK
DRYERS PER 45' / 48" TRUCK
VOLTAGE AVAILABLE
HEAT INPUT
3/7
9/9
208-460v / 3Ø / 3, 4w 50 / 60Hz
375,000 btu/hr 94,500 kcal/hr
APPROX. WEIGHT (Uncrated)
APPROX. WEIGHT (Crated)
AIRFLOW
1,500 lbs.
1,725 lbs.
2,150 cfm
1"
680.4 kg
782.5 kg
60.1 cmm*
2.54 cm
INLET SIZE
VOLTAGE AVAILABLE
208-600v / 3Ø / 3, 4w 50 / 60Hz
OVEN SIZE
kcal/hr
kw
72
80
btu/hr
Airflow
246,150
273,500
61,982
68,869
2,150 cfm 60.1 cmm
2,500 cfm 70.1 cmm
VOLTAGE AVAILABLE
APPROX. WEIGHT (Uncrated)
APPROX. WEIGHT (Crated)
HEAT INPUT
208-460v / 3Ø / 3, 4w 50 / 60Hz
1,650 lbs.
1,875 lbs.
748.4 kg
850.5 kg
13 Bhp
STEAM CONSUMPTION
AIRFLOW
450 lbs./hr
2,750 cfm
1-1/4"
202.2 kg/hr
77.9 cmm
3.18 cm
INLET SIZE
80 PSI COMPRESSED AIR
1/8" N.P.T.
.318 cm
Shaded areas are stated in metric equivalents.
IMPORTANT: Steam dryers must be provided with a clean, dry, regulated 80 PSI(+/-10 PSI)
air supply.
NOTE: ADC RESERVES THE RIGHT TO MAKE CHANGES IN SPECIFICATIONS AT
ANY TIME, WITHOUT NOTICE or OBLIGATION.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
ADG-120ES
ADE-120ES
ADS-120ES
NOTE: OPERATING HEIGHT OF STEAM DRYER
is 89 inches (226.1 cm).
EXHAUST
DIM.
"A"
DIM .
"A"
DUCT DIA.
GAS AND
ELECTRIC
12"
30.5 cm
16"
11-1/4"
28.6
9"
22.9 cm
9-1/2"
24.1 cm
9"
STEAM
40.6 cm
22.9 cm
NOTE: ADC RESERVES THE RIGHT TO MAKE CHANGES IN SPECIFICATIONS AT
ANY TIME, WITHOUT NOTICE or OBLIGATION.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
B. COMPONENT IDENTIFICATION
1. DRYER FRONT VIEW
Illus. No.
Description
1
2
3
4
5
6
7
Microprocessor Control / Keyboard Panel Assembly (Controls)
Control (Top Access) Door Assembly
Main Door Assembly
Lint Door Assembly
Lint Drawer
Wire Diagram (Located Behind Control Door)
Top Console (Module) Assembly
7
Download from Www.Somanuals.com. All Manuals Search And Download.
2. DRYER REAR VIEW
Illus. No.
Description
1
2
3
4
5
6*
7
Basket (Drive) Motor Assembly
Blower Motor Mount Assembly
Impellor (fan/blower) Assembly
Idler Bearing Mount Assembly
Tumbler Bearing Mount Assembly
Electric Service Relay Box
Heating Unit
8
Data Label and Installation Label
* Electric service connections are made in this box.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION III
INSTALLATION PROCEDURES
Installation should be performed by competent technicians in accordance with local and state codes. In the
absence of these codes, the installation must conform to applicable AMERICAN NATIONAL
STANDARDS:
ANSI.Z223.1-LATEST EDITION (National Fuel Gas Code)
and/or
ANSI/NFPA NO. 70-LATEST EDITION (National Electric Code)
or in CANADA, the installation must conform to applicable CANADIAN STANDARDS:
CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION (for
GENERAL INSTALLATION and GAS PLUMBING)
and/or
CANADIAN ELECTRICAL CODES PARTS 1 & 2 CSA C22.1-1990 or LATEST EDITION
(for ELECTRICAL CONNECTIONS).
A. LOCATION REQUIREMENTS
Before installing the dryer, be sure the location conforms to local codes and ordinances. In the absence of such
codes or ordinances the location must conform with the National Fuel Gas Code ANSI.Z223.1-
LATEST EDITION, or in CANADA, the Canadian Installation Codes CAN/CGA-B149.1-M91 (Natural Gas)
or CAN/CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION.
1. The dryer must be installed on a sound level floor capable of supporting its weight. It is recommended
that carpeting be removed from the floor area that the dryer is to rest on.
2. The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.
3. Provisions for adequate air supply must be provided as noted in this manual (refer to Fresh Air Supply
in Section D).
4. Clearance provisions must be made from combustible construction as noted in this manual (refer to
Dryer Enclosure Requirements in Section C).
5. Provisions must be made for adequate clearances for servicing and for operation as noted in this manual
(refer to Dryer Enclosure Requirements in Section C).
6. Dryer must be exhausted to the outdoors (refer to Exhaust Requirements in Section E).
7. Dryer must be located in an area where correct exhaust venting can be achieved as noted in the manual
(refer to Exhaust Requirements in Section E).
8. Dryer must be located in an area where correct exhaust venting can be achieved as noted in this manual
(refer to Exhaust Requirements in Section E).
IMPORTANT: Dryer should be located where a minimum amount of exhaust duct will be
necessary.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
B. UNPACKING/SETTING UP
Remove protective shipping material (i.e., plastic wrap, and/or optional shipping box) from dryer.
IMPORTANT: Dryer must be transported and handled in an upright position at all times.
The dryer can be moved to its final location while still attached to the skid or with the skid
removed. To un-skid the dryer, locate and remove the four (4) lag bolts securing the base of the dryer to the
wooden skid. Two (2) are located at the rear base (remove the back panel for access), and two (2) are located in
the bottom of the lint chamber. To remove the two (2) lag bolts located in the lint chamber area, remove the lint
drawer and the three (3) Phillips head screws securing lint door in place.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
1. LEVELING DRYER
a. To level dryer, place 4-inch square metal shims (refer to illustration above) or other suitable material
under the base pads. It is suggested that the dryer be tilted slightly to the rear.
2. If more headroom is needed when moving dryer into position, the top console (module) may be
removed.
a. To remove top console (module)
1) Disconnect the ground wire (A) at the Rear Upper Left Hand Corner of Dryer.
2) Remove the six (6) set of nuts and washers (B) holding the console (module) to base.
3) Open the control door/control panel and disconnect the white 15-pin plug connector (C in the
illustration below) located in the base of the control box.
4) Disconnect white plug connector located outside backside of the control box (provides power to
heat circuit).
5) Lift the console (module) off of the dryer base.
IMPORTANT: The dryer must be transported and handled in an upright position at all times.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
C. DRYER ENCLOSURE REQUIREMENTS
Even though a 12-inch clearance is acceptable, it is recommended that the rear of the dryer be positioned
approximately two (2) feet (24-inches) from the nearest obstruction (i.e., wall) for ease of installation, mainte-
nance, and service. Bulkheads and partitions should be made from noncombustible materials. The clearance
between the bulkhead header and the dryer must be a minimum of 4-inches and must not extend more than 4-
inches to the rear of the dryer front. The bulkhead facing must not be closed in all the way to the top of the dryer.
A 2-inch clearance is required.
NOTE: Bulkhead facing should not be installed until after dryer is in place. Ceiling area
must be located a minimum of 12-inches above the top of the dryer.
IMPORTANT: Even though a minimum of only 12-inches is required, 18-inches or more is
suggested, for steam dryers and especially in cases where sprinkler heads are
over the dryers.
NOTE: When fire sprinkler systems are located above the dryers, a minimum of 18-inches
above the dryer console (module) is suggested. Dryers may be positioned side wall
to side wall however, 1 or 2-inches is suggested between dryers (or wall) for ease of
installation and maintenance. Allowances must be made for the opening and closing
of the control and lint doors.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
D. FRESH AIR SUPPLY
When the dryer is operating, it draws in room air, heats it, passes this air through the basket (tumbler), and
exhausts it out of the building. Therefore, the room air must be continually replenished from the outdoors. If the
make-up air is inadequate, drying time and drying efficiency will be adversely affected. Ignition problems and
sail switch "fluttering" problems may result, as well as premature motor failure from overheating.
Air supply (make-up air) must be given careful consideration to assure proper performance of each dryer. An
unrestricted source of air is necessary for each dryer. An airflow of 2,150 cfm (cubic feet per minute) must be
supplied to each gas dryer and electric dryer with a 72 Kw oven, 2,500 cfm to each electric dryer with a 80 Kw
oven, and 2,750 cfm for each steam dryer. As a general rule, an unrestricted air entrance from the outdoors
(atmosphere) of a minimum of three (3) square feet is required for each gas dryer and 72 Kw electric dryer and
a minimum of five (5) square feet for each steam dryer and 80 Kw electric dryer.
To compensate for the use of registers or louvers used over the openings, this make-up air area must be increased
by approximately thirty-three (33) percent. Make-up air openings should not be located in an area directly near
where exhaust vents exit the building.
It is not necessary to have a separate make-up air opening for each dryer. Common make-up air openings are
acceptable. However, they must be set up in such a manner that the make-up air is distributed equally to ALL the
dryers.
EXAMPLE: For a bank of six (6) gas dryers, two (2) openings measuring 3 feet by 3 feet
(9 square feet) is acceptable.
Allowances must be made for remote or constricting passageways or where dryers are located at excessive
altitudes or predominantly low pressure areas.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT: Make-up air must be provided from a source free of dry cleaning solvent fumes.
Make-up air that is contaminated by dry cleaning solvent fumes will result in
irreparable damage to motors and other dryer components.
NOTE: Component failure due to dry cleaning solvent fumes will VOID THE WARRANTY.
E. EXHAUST REQUIREMENTS
1. GENERAL EXHAUST DUCT WORK INFORMATION
Exhaust duct work should be designed and installed by a qualified professional. Improperly sized duct
work will create excessive back pressure which results in slow drying, increased use of energy,
overheating of the dryer, and shutdown of the burner by the airflow (sail) switches, burner hi-limits, or
basket (tumbler) hi-heat thermostats..
CAUTION: DRYER MUST BE EXHAUSTED TO THE OUTDOORS.
CAUTION: IMPROPERLY SIZED OR INSTALLED EXHAUST DUCT WORK CAN
CREATE A POTENTIAL FIRE HAZARD.
NOTE: When a dryer is exhausted separately, it is recommended that a back draft damper be
installed.
NOTE: When dryers are exhausted into a multiple (common) exhaust line, each dryer must be
supplied with a back draft damper.
The exhaust duct work should be laid out in such a way that the duct work travels as directly as
possible to the outdoors with as few turns as possible. Single or independent dryer venting is
recommended. When single dryer venting is used, the duct work from the dryer to the outside exhaust
outlet should not exceed twenty (20) feet. In the case of multiple (common) dryer venting, the distance
from the last dryer to the outside exhaust outlet should not exceed twenty (20) feet. The shape of the
duct work is not critical so long as the minimum cross section area is provided. It is suggested that the
use of 90º turns in ducting be avoided; use 30º and/or 45º angles instead. The radius of the elbows should
preferably be 1-1/2 times the diameter of the duct. Excluding basket/dryer elbow connections or elbows
used for outside protection from the weather, no more than two (2) elbows should be used in the exhaust
duct run. If more than two (2) elbows are used, the cross section area of the duct work must be increased in
proportion to number of elbows added.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
ALL duct work should be smooth inside with no projections from sheet metal screws or other obstructions
which will collect lint. When adding ducts, the ducts to be added should overlap the duct to which it is con-
nected. ALL duct work joints must be taped to prevent moisture and lint from escaping into the building.
Additionally, inspection doors should be installed at strategic points in the exhaust duct work for periodic
inspection and clean-out of lint from the duct work.
To protect the outside end of horizontal duct work from the weather, a 90° elbow bent downward
should be installed where the exhaust exits the building. If the duct work travels vertically up through
the roof, it should be protected from the weather by using a 180° turn to point the opening downward.
In either case, allow at least twice the diameter of the duct between the duct opening and the nearest
obstruction (i.e., roof or ground level).
IMPORTANT: Exhaust back pressure measured by a manometer at the dryer exhaust duct area
must not exceed 0.3 inches of water column.
NOTE:Where the exhaust duct work passes through a wall, ceiling, or roof made of
combustible materials, the opening must be 2-inches larger (all the way around) than
the duct. The duct must be centered within this opening.
a. Outside Duct Work Protection
1) To protect the outside end of horizontal duck work from the weather, a 90° elbow bent downward
should be installed where the exhaust exits the building. If the exhaust duct work travels vertically
up through the roof, it should be protected from the weather by using a 180° turn to point the
opening downward. In either case, allow at least twice the diameter of the duct between the duct
opening and the nearest obstruction.
IMPORTANT: DO NOT use screens or caps on the outside of opening of exhaust duct work.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
2. SINGLE DRYER VENTING
Where possible, it is suggested to provide a separate exhaust duct for each dryer. The exhaust duct
should be laid out in such a way that the duct work travels as directly as possible to the outdoors with as
few turns as possible. It is suggested that the use of 90° turns in ducting be avoided; use 30° and/or 45°
angles instead. The shape of the exhaust duct work is not critical so long as the minimum cross section
area is provided.
IMPORTANT: Minimum duct size for a gas dryer or 72 Kw electric dryer is 14-inches for
a round duct or 12.50" for a square duct. The minimum duct size for a
steam dryer or 80 Kw electric dryer is 16-inches for a round duct or
14.50" x 14.50" for a square duct. Duct size must not be reduced anywhere
down stream of dryer.
IMPORTANT: Exhaust back pressure measured by a manometer at each basket (tumbler)
exhaust duct area should not exceed 0.3 inches of water column.
It is suggested that the duct work from each dryer (minimum 14-inches for a gas dryer or 72 Kw electric
dryer and 16-inches for a steam dryer or 80 Kw electric dryer) not exceed twenty (20) feet with no more
than two (2) elbows (excluding dryer connections and outside exhaust outlets). If the duct work exceeds
twenty (20) feet or has numerous elbows, the cross section area of the duct work must be increased in
proportion to the length and number of elbows in it. In calculating duct size, the cross section area of a
square or rectangular duct must be increased by twenty (20) percent for each additional twenty (20) feet.
The diameter of a round exhaust duct should be increased ten (10) percent for each additional fifteen (15)
feet. Each 90° elbow is equivalent to an additional thirty (30) feet, and each 45° elbow is equivalent to an
additional fifteen (15) feet.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT: For extended duct work runs, the cross section area of the duct can only be
increased to an extent. Maximum proportional duct work runs cannot exceed
twenty (20) feet more than the original limitations of twenty (20) feet with
two (2) elbows. When the duct work approaches the maximum limits as
noted in this manual, a professional heating venting air conditioning (HVAC)
firm should be consulted for proper venting information.
ALL duct work should be smooth inside with no projections from sheet metal screws or other obstructions
which will collect lint. When adding ducts, the duct to be added should overlap the duct to which it is to be
connected. ALL duct work joints must be taped to prevent moisture and lint from escaping into the building.
Inspection doors should be installed at strategic points in the exhaust duct work for periodic inspection and
clean-out of lint from the duct work.
NOTE: Where the exhaust duct passes through a wall, ceiling, or roof made of combustible
materials, the opening must be 2-inches larger (all the way around) than the duct.
The duct must be centered within this opening.
a. Outside Duct Work Protection
1) To protect the outside end of horizontal duct work from the weather, a 90° elbow bent downward
should be installed where the exhaust exits the building. If the exhaust duct work travels vertically
up through the roof, it should be protected from the weather by using a 180° turn to point the opening
downward. In either case, allow at least twice the diameter of the duct between the duct opening and
nearest obstruction.
IMPORTANT: DO NOT use screens, louvers, or caps on the outside of opening of exhaust duct
work.
3. MULTIPLE DRYER (COMMON) VENTING
If it is not feasible to provide separate exhaust ducts for each dryer, ducts from individual dryers may be
channeled into a "common main duct". The individual ducts should enter the bottom or side of the main
duct at an angle not more than 45° in the direction of air flow and should be spaced at least 48-3/8 inches
apart. The main duct should be tapered, with the diameter increasing before each individual 14-inch
(minimum for gas dryers or 72 Kw electric dryers) or 16-inch (minimum for steam dryers or 80 Kw electric
dryers) duct is added.
IMPORTANT: The AD-120ES is not provided with a back draft damper. When exhausted into
a multiple (common) exhaust line, a back draft damper must be installed at
each dryer duct.
IMPORTANT: No more than four (4) dryers should be connected to one main common duct.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
The main duct may be any shape or cross sectional area, so long as the minimum cross section area is provided.
The illustrations on page 19 and page 20 show the minimum cross section area for multiple dryer round or
square venting. These figures must be increased 10 square inches when rectangular main ducting is used, and
the ratio of duct width to depth should not be greater than 3-1/2 to 1. These figures must be increased in
proportion if the main duct run to the last dryer to where it exhausts to the outdoors is unusually long (over
twenty [20] feet) or has numerous elbows (more than two [2]) in it. In calculating duct work size, the cross
section area of a square or rectangular duct must be increased twenty (20) percent for each additional twenty
(20) feet. The diameter of a round exhaust must be increased ten (10) percent for each additional twenty (20)
feet. Each 90° elbow is equivalent to an additional fifteen (15) feet.
IMPORTANT: For extended duct work runs, the cross section area of the duct work can only be
increased to an extent. Maximum proportional duct work runs cannot exceed
twenty (20) feet more than the original limitations of twenty (20) feet with two
(2) elbows. When the duct work approaches the maximum limits as noted in
this manual, a professional HVAC firm should be consulted for proper
venting information.
IMPORTANT: Exhaust back pressure measured by a manometer at each dryer exhaust duct area
should not exceed 0.3 inches of water column.
The duct should be smooth inside with no projections from sheet metal screws or other obstructions which will
collect lint. When adding ducts, the duct to be added should overlap the duct to which it is to be connected.
ALL duct work joints must be taped to prevent moisture and lint from escaping into the building. Inspection
doors should be installed at strategic points in the exhaust duct work for periodic inspection and clean-out of
lint from the duct work.
NOTE: Where the exhaust passes through a wall, ceiling, or roof made of combustible materials,
the opening must be 2-inches larger (all the way around) than the duct. The duct must
be centered within this opening.
a. Outside Duck Work Protection
1) To protect the outside end of horizontal duct work from the weather, a 90° elbow bent downward
should be installed where the exhaust exits the building. If the exhaust duct work travels vertically
up through the roof, it should be protected from the weather by using a 180° turn to point the opening
downward. In either case, allow at least twice the diameter of the duct between the duct opening and
nearest obstruction.
IMPORTANT: DO NOT use screens, louvers, or caps on the outside of opening of exhaust
duct work.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
ADG-120ES FOR GAS MODELS
ADE-120ES FOR 80 KW ELECTRIC MODELS
19
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTIPLE DRYER VENTING (ADS-120ES)
WITH 16" DIAMETER (2,750 CFM) EXHAUST CONNECTIONS AT COMMON DUCT
20
Download from Www.Somanuals.com. All Manuals Search And Download.
F. ELECTRICAL INFORMATION
1. Electrical Requirements
It is your responsibility to have ALL electrical connections made by a properly licensed and competent
electrician to assure that the electrical installation is adequate and conforms with local and state
regulations or codes. In the absence of such codes, ALL electrical connections, material, and
workmanship must conform to the applicable requirements of the National Electrical Code ANSI/NFPA
NO.70-LATEST EDITION, or in CANADA, the Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990
or LATEST EDITION.
IMPORTANT: Failure to comply with these codes or ordinances, and/or the requirements
stipulated in this manual can result in personal injury or component failure.
NOTE: Component failure due to improper installation will VOID THE WARRANTY.
Each dryer should be connected to an independently protected branch circuit. The dryer must be
connected with copper wire ONLY. DO NOT use aluminum wire which could cause a fire hazard. The
copper conductor wire/cable must be of proper ampacity and insulation in accordance with electric codes
for making ALL service connections.
NOTE: The use of aluminum wire will VOID THE WARRANTY.
NOTE: Wiring diagrams are affixed to the inside at the top front control door and to the rear
upper back guard / panel.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Electrical Service Specifications
ADG-1 2 0 ES Reversin g, 3 ø (GAS)
ADS-1 2 0 ES Reversin g, 3 ø (STE AM )
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT: 208 VAC and 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTES: A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5 ONLY.
B. Circuit breakers are thermal magnetic (industrial) type ONLY . For others, calculate/verify correct breaker size
according to appliance amp draw rating and type of breaker used.
C. Circuit breakers for 3Ø dryers must be 3-pole type.
FUSING
Dual Element
Time Delay
APPROX.
AMP DRAW
CIRCUIT
BREAKER
SERVICE
VOLTAGE
WIRE
SERVICE
MINIMUM
WIRE SIZE*
PHASE
60 Hz 50 Hz
60 Hz 50 Hz 60 Hz 50 Hz
120
240
380
416
460
480
575
3ø
3ø
3ø
3ø
3ø
3ø
3ø
3/4
3
14.6
13.3
8
---
14
7.6
7.4
---
7
14
14
14
14
14
14
14
20
20
12
---
---
10
10
---
20
10
10
---
---
10
25
25
15
---
15
15
15
---
25
15
15
---
---
15
3/4
3/4
3/4
3/4
3
---
7.1
7.1
6.3
---
* AWG Stranded Type Wire ... for individual lengths less than 100 feet.
(Motor lead type wire is recommended)
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is
affixed to the back of the dryer, at the upper right hand corner. In the case of
208 VAC or 240 VAC, the supply voltage must match the electric service
specifications of the data label exactly.
WARNING: 208 VAC and 240 VoltsARE NOT THE SAME. Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: ADC reserves the right to make changes in specifications at any time, without notice or
obligation.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
ADE-1 2 0 ES (7 2 Kw Elect ric) Reversin g, 3 ø
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT: 208 VAC and 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTES: A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5 ONLY.
B. Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size according to
appliance amp draw rating and type of breaker used.
C. Circuit breakers for 3Ø dryers must be 3-pole type.
APPROX.
AMP DRAW
60 Hz 50 Hz
FUSING
Dual Element
Time Delay
OVEN SIZE SERVICE
WIRE
SERVICE
MINIMUM
WIRE SIZE*
CIRCUIT
BREAKER
PHASE
((Kw)
VOLTAGE
72
72
72
72
72
72
72
72
72
208
240
3ø
3ø
3ø
3ø
3ø
3ø
3ø
3ø
3ø
3
3
214
186
117
117
---
---
187
117
117
107
107
---
4/0
3/0
1
300
250
150
150
150
150
150
150
100
300
250
150
150
150
150
125
125
110
380
3
380
4
1
416
3
2
416
4
---
2
480
3
98
3
480
98
---
3
4
575/600
3/4
79.4
---
4
* AWG Stranded Type Wire ... for individual lengths less than 100 feet.
(Motor lead type wire is recommended)
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is
affixed to the back of the dryer, at the upper right hand corner. In the case of
208 VAC or 240 VAC, the supply voltage must match the electric service
specifications of the data label exactly.
WARNING: 208 VAC and 240 VoltsARE NOT THE SAME. Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: ADC reserves the right to make changes in specifications at any time, without notice or
obligation.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
ADE-1 2 0 ES (8 0 Kw Elect ric) Reversin g, 3 ø
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT: 208 VAC and 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTES: A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5 ONLY.
B. Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size according to
appliance amp draw rating and type of breaker used.
C. Circuit breakers for 3Ø dryers must be 3-pole type.
APPROX.
AMP DRAW
60 Hz 50 Hz
FUSING
Dual Element
Time Delay
300
OVEN SIZE SERVICE
WIRE
SERVICE
MINIMUM
WIRE SIZE*
CIRCUIT
BREAKER
PHASE
((Kw)
VOLTAGE
80
80
80
80
80
80
80
80
80
80
208
240
380
380
416
416
480
480
575
600
3ø
3ø
3ø
3ø
3ø
3ø
3ø
3ø
3ø
3ø
235
206
---
---
208
130
130
119
119
---
250 MCM
300
300
175
175
150
150
150
150
125
125
3
3
4/0
1
300
175
175
150
150
150
150
125
125
3
4
---
1
3
---
1
4
---
1
188
108
88
2
3
---
2
4
---
3
3/4
3/4
85
---
3
* AWG Stranded Type Wire ... for individual lengths less than 100 feet.
(Motor lead type wire is recommended)
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is
affixed to the back of the dryer, at the upper right hand corner. In the case of
208 VAC or 240 VAC, the supply voltage must match the electric service
specifications of the data label exactly.
WARNING: 208 VAC and 240 VoltsARE NOT THE SAME. Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: ADC reserves the right to make changes in specifications at any time, without notice or
obligation.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
3. ElectricalConnections
NOTE: A wiring diagram is included with each dryer and is affixed to the rear upper right guard/
panel of the dryer.
The only electrical input connections to the dryer are the 3-phase (3Ø) power leads (L1, L2, and L3),
GROUND, and in the case of 4 wire service, the neutral. Providing local codes permit, power connections
to the dryer can be made by the use of a flexible underwriters laboratory listed cord/pigtail (wire size must
conform to rating of the dryer), or the dryer can be hard wired directly to the service breaker. In ALL
cases, a strain relief must be used where the wire(s) enter the dryer electrical service (relay) box.
a. Gas Models and Steam Models Dryers
These electrical connections are made at the terminal block located in the electric service/relay box at the
rear, upper left hand corner of the dryer. To gain access into this service box, the service cover (upper
back guard) must be removed.
b. Electric Model Dryers
For electric model dryers made to operate at 208 VAC, 230 VAC, or 240 VAC, the electrical input
connection is made into the terminal block located at the upper rear of the dryer (refer to the illustration
on page 27). For electric model dryers made to operate at 380 VAC, 416 VAC, 440 VAC, or 480 VAC,
the electrical input connection is made to the oven relay located at the upper rear of the dryer (refer to the
illustration on page 27). Input connection wiring must be sized properly to handle the dryer's current
draw. This information is printed on the dryer's data label which is affixed to the rear, upper right hand
corner of the dryer.
NOTE: A CIRCUIT SERVING EACH DRYER MUST BE PROVIDED.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Grounding
Grounding (earth) connections must be provided and installed in accordance with state and local codes. In
the absence of the codes, grounding must conform to applicable requirements of the National Electric
Code ANSI/NFPA NO.70LATEST EDITION, or in CANADA, the Canadian Electrical Codes Parts 1 &
2 CSA C22.1-1990 or LATEST EDITION. The ground connection may be to a proven earth ground at
the location service panel.
NOTE: A grounding connection (terminal lug) is provided in the dryer's electrical service/relay
box at the rear.
For added personal safety, when possible, it is suggested that a separate ground wire (sized per local codes)
be connected from the ground connection of the dryer to a grounded cold water pipe. DO NOT ground to
a gas or hot water pipe. The grounded cold water pipe must have metal to metal connections all the way to
electrical ground. If there are any non-metallic interruptions, such as a meter, pump, plastic, rubber, or
other insulating connectors, theymust be jumped out with no. 4 copper wire and securely clamped to bare
metal at both ends.
IMPORTANT: For personal safety and proper operation, the dryer must be grounded. For
proper operation of the microprocessor (computer), an earth (zero) ground is
required.
NOTE: Grounding via metallic electrical conduit (pipe) is not recommended.
26
Download from Www.Somanuals.com. All Manuals Search And Download.
G. GAS INFORMATION
It is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the gas
plumbing installation is adequate and conforms with local and state regulations or codes. In the absence of such
codes, ALL plumbing connections, materials, and workmanship must conform to the applicable
requirements of the National Fuel Gas Code ANSI Z223.1-LATEST EDITION, or in CANADA, the Canadian
Installation Codes CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91(L.P. Gas) or LATEST
EDITION.
IMPORTANT: Failure to comply with these codes or ordinances, and/or the requirements
stipulated in this manual, can result in PERSONAL INJURY and IMPROPER
OPERATION of the dryer.
The dryer and its individual shut-off valves must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The dryermust be isolated from
the gas supply piping system by closing its individual manual shut-off valve during any pressure test of the gas
supply system at test pressures equal to or less than 1/2 psig (3.5 kPa).
IMPORTANT: Failure to isolate or disconnect the dryer from supply as noted can cause irreparable
damage to the gas valve VOIDING THE WARRANTY.
WARNING: FIRE or EXPLOSION COULD RESULT.
1. Gas Supply
The gas dryer installation must meet the American National Standard...National Fuel Gas Code ANSI Z223.1-
LATEST EDITION, as well as local codes and ordinances and must be done by a qualified professional.
NOTE: Undersized gas piping will result in ignition problems, slow drying, increased use of
energy, and can create a safety hazard.
The dryer must be connected to the type of heat/gas indicated on the dryer label affixed behind the right control
box door. If this information does not agree with the type of gas available, DO NOT operate the dryer.
Contact the distributor who sold the dryer or the ADC factory.
IMPORTANT: Any burner changes or conversions must be made by a qualified professional.
The input ratings shown on the dryer data label are for elevations up to 2,000 feet, unless elevation requirements
of over 2,000 feet were specified at the time the dryer order was placed with the factory. The adjustment or
conversion of dryers in the field for elevations over 2,000 feet are made by changing each burner orifice. If this
conversion is necessary, contact the distributor who sold the dryer or contact the ADC factory.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Technical Gas Data
a. Gas Specifications
Type of Gas
Natural
Liquid Propane
10.5 inches W.C.
10.5 inches W.C.
Manifold Pressure*
Inline Pressure
3.5 inches W.C.
6.0 to 12.0 inches W.C.
* Measured at gas valve pressure tap when the gas valve is on.
b. Gas Connections:
Inlet connection ----- 1-inch N.P.T.
Inlet supply size ----- 1-inch N.P.T. (minimum)
Btu/hr input (per dryer) ----- 375,000
1) Natural Gas
Regulation is controlled by the dryer's gas valve's internal regulator. Incoming supply pressure must
be consistent between a minimum of 6.0 inches and a maximum of 12.0 inches water column
pressure.
2) Liquid Propane (L.P.) Gas
Dryers made for use with L.P. gas have the gas valve's internal pressure regulator blocked open so
that the gas pressure must be regulated upstream of the dryer. The pressure measured at each gas
valve pressure tap must be a consistent 11.0 inches water column. There is no regulator or regulation
provided in an L.P. dryer. The water column pressure must be regulated at the source (L.P. tank) or
an external regulator must be added to each dryer.
Type of Gas
L.P.
Conversion
Natural
Liquid Propane
BTU
Per Hour
Rating
Model
Number
Kit
Part
Part
Part Number
Qty. D.M.S.*
Qty. D.M.S.*
Number
Number
140819
ADG-120ES
375,000
2
#4
140832
3
#30
880886
* D.M.S. (Drill Material Size) equivalents are as follows:
Natural Gas ...................... #4 = .2090"
Liquid Propane Gas ......... #30 = .1285"
28
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Piping/Connections
ALL components/materials must conform to National Fuel Gas Code Specifications, or in CANADA, the
Canadian Installation Codes (for General Installation and Gas Plumbing). It is important that gas pressure
regulators meet applicable pressure requirements and that gas meters be rated for the total amount of all the
appliance Btu's being supplied.
The dryer is provided with a 1-inch N.P.T. inlet pipe connection extending out the back area of the burner box.
The minimum pipe size connection (supply line) to the dryer is 1-inch N.P.T. For ease of servicing, the gas
supply line of each dryer must have its own shut-off valve.
The size of the main gas supply line (header) will vary depending on the distance this line travels from the gas
meter or, in the case of L.P. gas, the supply tank, other gas-operated appliances on the same supply line, etc.
Specific information regarding supply line size should be determined by the gas supplier.
NOTE: Undersized gas supply piping can create a low or inconsistent pressure which will result
in erratic operation of the burner ignition system.
Consistent gas pressure is essential atALL gas connections. It is recommended that a 1-inch pipe gas loop be
installed in the supply line serving a bank of dryers. An in-line pressure regulator must be installed in the gas
supply line (header) if the (natural) gas pressure exceeds 12.0 inches of water column pressure.
IMPORTANT: A water column pressure of 3.5 to 4.0 inches for natural gas and 11.0 inches for
L.P. dryers is required at the gas valve pressure tap of each dryer for proper and
safe operation.
A 1/8-inch N.P.T. plugged tap, accessible for a test gauge connection, must be installed in the main gas supply
line immediately upstream of each dryer.
IMPORTANT: Pipe joint compounds that resist the action of natural and L.P. gases must be
used.
IMPORTANT: Test ALL connections for leaks by brushing on a soapy water solution
(liquid detergent works well).
WARNING: NEVER TEST FOR GAS LEAKS WITH A FLAME!!!
ALL components/materials must conformto National Fuel Gas Code Specifications ANSI Z223.1-LATEST
EDITION, or in CANADA, the Canadian Installation Codes CAN/CGA-B149.1-M91 (Natural Gas) or CAN/
CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION.
It is important that gas pressure regulators meet applicable pressure requirements, and that gas meters be rated
for the total amount of appliance Btu's being supplied.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT: The dryer and its individual shut-off valve must be disconnected from the gas
supply piping system during any pressure testing of that system at test pressures
in excess of 1/2 psig (3.5kPa).
NOTE: The dryer must be isolated from the gas supply piping system by closing its individual
manual shut-off valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig (3.5kPa).
30
Download from Www.Somanuals.com. All Manuals Search And Download.
H. STEAM INFORMATION
It is your responsibility to have ALL steam plumbing connections made by a qualified professional to assure that
the installation is adequate and conforms with local and state regulations or codes.
IMPORTANT: Failure to comply with the requirements stipulated in this manual can result in
component failure which will VOID THE WARRANTY.
NOTE: The ADS-120ES is manufactured with a pneumatic (piston) damper system which
requires an external supply of clean, dry, regulated air (80 psi +/- 10 psi). Refer to
Steam Damper Air System Connections, Section H, item 3.
1. STEAM COIL PH LEVEL
The normal PH level for copper type steam coils must be maintained between a value of 8.5 to 9.5. For steel
type steam coils the PH level must be maintained between a value of 9.5 to 10.5. These limits are set to limit
the acid attack of the steam coils.
IMPORTANT: Coil failure due to improper PH level will VOID THE WARRANTY.
2. STEAM REQUIREMENTS , HIGH PRESSURE
a. Inlet ---- 1-1/4-inch supply line connection --- qty. one (1) at top manifold.
b. Return -- 1-1/4-inch return line connection --- qty. one (1) at bottom manifold.
Operating Steam Pressure
Maximum
125 psig
100 psig
13 Bhp
Minimum
Heat Input (Normal Load)
Consumption (Approximate)
450 lbs/hr
3. INSTALLATION INSTRUCTIONS
To insure that an adequate supply of steam is provided, be sure that the steam supply and steam return lines
are sized and laid out as stipulated in this manual. Inadequate steam supply and steam return lines are sized
and laid out as stipulated in this manual. Inadequate steam supply and steam return lines or improper steam
plumbing will result in poor performance and can cause component failure. Clean, dry, regulated steam
must be provided to the dryer.
IMPORTANT: Steam coil failure due to water hammer by wet steam will VOID THE
WARRANTY.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
a. The pressure of the condensate in the steam supply will cause water hammer and subsequent heat
exchanger (steam coil) failure. The steam supply connection into the main supply linemust be made
b. The steam supply piping to the dryermust include a 12-inch rise along with a drip trap and check valve.
This will prevent any condensate from entering the steam coil.
c. Flexible hoses or couplings must be used. The dryer vibrates slightly when it runs and this will cause the
steam coil connections to crack if they are hard piped to the supply and return mains.
d. Shut-off valves for each dryer should be installed in the supply, return, and drip trap return lines. This
will allow the dryer to be isolated from the supply and return mains if the dryer needs maintenance work.
e. Install an inverted bucket steam trap and check valve for each unit at least 12-inches below steam coil as
close to the coil as possible.
1) A trap with a capacity of 1,200 pounds of condensate per hour at 125 psi is needed for each unit.
f. A 3/4" vacuum breaker should be installed for each unit in the piping. This will prevent the condensing
steam from causing a vacuum inside the coil and possibly damaging the coil.
g. The supply and return lines should be insulated. This will save energy and provide for safety of the
operator and maintenance personnel.
h. Water pockets in the supply line, caused by low points, will provide wet steam to the coil possibly causin
coil damage. ALL horizontal runs of steam supply piping should be pitched 1/4-inch for every one (1)
foot back towards the steam supply header causing any condensate in the line to drain to the header.
Install a bypass trap in any low point to eliminate wet steam.
STEAM DAMPER SYSTEM
32
Download from Www.Somanuals.com. All Manuals Search And Download.
3. STEAM DAMPER AIR SYSTEM CONNECTIONS
The ADS-120ES is manufactured with a pneumatic (piston) damper system which requires an external
supply of compressed air. The air connection is made to the steam damper solenoid valve which is located
at the rear inner top area of the dryer just above the electric service relay box (refer to the bottom
illustration on page 34).
a. Air Requirements
Compresses Air Supply
Air Pressure
Normal
80 psi
70 psi
90 psi
Minimum Supply
Maximum Supply
b. Air Connection
Air connection to system --- 1/8-inch N.P.T.
c. No air regulation or filtration is provided with the dryer. External regulation/filtration of 80 psimustbe
provided. It is suggested that a regulator/filter gauge arrangement be added to the compressed air line
just before the dryer connection. This is necessary to insure that correct and clean air pressure is achieved.
4. STEAM DAMPER SYSTEM OPERATION
The ADS-120ES steam damper, as shown in the top illustration on page 34, allows the coil to stay
constantly charged eliminating repeated expansion and contraction. When the damper is opened, the air
immediately passes through the already hot coil, providing instant heat to start the drying process. When
the damper is closed, ambient air is drawn directly into the basket (tumbler), allowing a rapid cool down.
Diagram 1 -- shows the damper in the heating (open) mode, allowing heat into the basket (tumbler).
Diagram 2 -- shows the damper in the cool down (closed) mode, pulling ambient air directly into the basket
(tumbler) without passing through the coils.
NOTE: With the dryer off or with no air supply, the damper is in the cool down mode as shown
in Diagram 2.
33
Download from Www.Somanuals.com. All Manuals Search And Download.
5. STEAM DAMPER AIR PISTON (FLOW CONTROL) OPERATION ADJUSTMENT
Although the damper operation was tested and adjusted prior to shipping at 80 psi, steam damper operation
must be checked before the dryer is put into operation. Refer topage 37 for instructions to check system
damper operation. If damper air adjustment is necessary, locate flow control valve and make necessary
adjustments as noted below.
34
Download from Www.Somanuals.com. All Manuals Search And Download.
I. PREPARATION FOR OPERATION
The following items should be checked before attempting to operate the dryer:
1. Read ALL "CAUTION," "WARNING," and "DIRECTION" labels attached to the dryer.
2. Check incoming supply voltage to be sure that it is the same as indicated on the dryer data label located in
the front top console area as shown on page 8. In case of 208 VAC or 230/240 VAC, the supply voltage
must match the electric service exactly.
3. GAS MODELS - check to assure that the dryer is connected to the type of heat/gas indicated on the
dryer data label.
4. GAS MODELS- the sail switch damper assembly was installed and adjusted at the factory prior to
shipping. However, each sail switch adjustment must be checked to assure that this
important safety control is functioning.
5. GAS MODELS - be sure that ALL gas shut-off valves are in the open position.
6. Be sure ALL back panels (guards) and electric box covers have been replaced.
7. Check ALL service doors to assure that they are closed and secured in place.
8. Be sure lint drawer is securely in place.
NOTE: LINT DRAWER MUST BE ALL THE WAY IN PLACE TO ACTIVATE SAFETY
SWITCH OTHERWISE THE DRYER WILL NOT START.
9. Rotate the basket (tumbler) by hand to be sure it moves freely.
10. Check bolts, nuts, screws, terminals, and fittings for security.
11. STEAM MODELS - check to insure air supply (80 psi) is on to the dryer.
12. STEAM MODELS - check to insure ALL steam shut-off valves are open.
13. STEAM MODELS - check steam damper operation.
14. Check tumbler bearing set screws to insure they are ALL tight.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
J. PREOPERATIONAL TESTS
ALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test
shouldbe performed before the dryer is publicly used. It is possible that adjustments have changed in transit or
due to marginal location (installation) conditions.
1. Turn on electric power to the dryer.
2. Make sure the main door is closed and the lint drawer is securely in place.
3. Refer to the Operating Instructions for starting your particular dryer.
4. Check to insure that the basket (tumbler) starts in the clockwise (CW) direction. Additionally, check the
direction of the blower motor impellor (fan) to insure that impellor (fan) rotates in the clockwise (CW)
direction as viewed from the front. If it is, the phasing is correct. If the phasing is incorrect, reverse two (2)
of the leads at L1, L2, or L3 of the power supply connections made to the dryer.
IMPORTANT: Dryer blower motor impellor/fan as viewed from the front must turn in the
clockwise (CW) direction, otherwise dryer efficiency will drastically be reduced
and premature component failure can result.
5. HEAT CIRCUIT OPERATIONAL TEST
a. Gas Models
1) When the dryer is first started (during initial start-up), the burner has a tendency not to ignite on the
first attempt. This is because the gas supply piping is filled with air, so it may take a few minutes for
this air to be purged from the lines.
2) The dryer is equipped with a direct spark ignition (DSI) system which has internal diagnostics. If
ignition is not established after the first attempt, the heat circuit DSI module will lock out until it is
manually reset. To reset the DSI system, open and close main door and restart dryer (press the
"ENTER/START" key).
NOTE: During the purging period, check to be sure that ALL gas shut-off valves are open.
3) Once ignition is established, a gas pressure testshouldbe taken at the gas valve pressure tap of each
dryer to assure that the water column pressure is correct and consistent.
NOTE: Water column pressure requirements (measured at the gas valve pressure tap)...
NATURAL GAS --- 3.5-4.0 INCHES W.C.
L.P. GAS ------------ 10.5 - 11.0 INCHES W.C.
36
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT: There is no regulator provided in an L.P. dryer. The water column pressure
must be regulated at the source (L.P. tank) or an external regulator must be
added to each dryer.
b. Electric Models
1) Check the oven contactor(s) to insure that the electric oven is cycling properly.
c. Steam Models
1) Check to insure that steam damper is functioning properly.
a) The steam damper should not "slam" (open or closed) when it reaches the end of (piston) travel.
Additionally, the steam damper should not bind and/or stop during travel. If either of these
conditions occur, the flow controlmust be adjusted. Refer to the bottom illustration onpage 35
for air adjustment instructions.
6. Make a complete operational check of ALL safety-related circuits (i.e., lint drawer switch, and sail switch
on gas models).
NOTE: To check for proper sail switch operation, open the main door and while holding main
door switch plunger in, start dryer. Dryer should start but heat circuit should not be
activated (on). If heat (burner) does activate, shut dryer off and make necessary
adjustments.
7. A reversing basket (tumbler) dryer should never be operated with less than a 60 lb. load (dry weight). The
size of the load will affect the coast-down and dwell (stop) times. The basket (tumbler) must come to a
complete stop before starting in opposite direction.
a. Microprocessor (computer) Dryer Models
1) Spin and stop timesare notadjustable in the Automatic Mode and have been preprogrammed into
the microprocessor controller (computer) for 120-seconds spin time and a 5-second dwell (stop)
time.
2) Spin and stop times are adjustable in the Manual (timed) Mode.
b. Dual Timer Dryer Models
1) Spin and stop times are adjustable at the reversing timer (refer topage 58).
IMPORTANT: The dryer basket (tumbler) is treated with a protective coating ADC suggests
tumbling old clothes or material in the basket (tumbler), using a mild detergent
to remove the protective coating.
37
Download from Www.Somanuals.com. All Manuals Search And Download.
8. Each dryer should be operated through one complete cycle to assure that no further adjustments are
necessary and that ALL components are functioning properly.
9. Make a complete operational check of ALL operating controls.
a. Microprocessor controller (computer) programs/selections...
1) Each microprocessor controller (computer) has been preprogrammed by the factory with the most
commonly used parameter (program) selections. If computer program changes are required, refer to
the computer programming manual which was shipped with the dryer.
b. Dual timer dryers check...
1) Heating Timer
2) Cool Down Timer
3) Temperature Selection Switch
38
Download from Www.Somanuals.com. All Manuals Search And Download.
K. OPERATING INSTRUCTIONS
NOTE: Before attempting to start the dryer make sure that the main door is closed and the
lint drawer is securely in place.
1. To start the dryer.
a. Microprocessor (Computer) Dryers
1) Display will read "FILL" (meaning no cycle in progress).
2) Press the letter on the keyboard (touchpad) corresponding to the cycle desired (i.e., Ke "E")...
a) The dryer will then start (rotate).
3) L.E.D. display will now show the Cycle In progress and Cycle status (i.e., "dr30") meaning that the
dryer is in the drying cycle (dry mode for 30 minutes) and count down in minutes.
NOTE: Pressing touch pad key "A," "B," "C," "D," and "F" will also start the dryer. The six (6)
preprogrammed drying cycles ("A" through "F") have been stored in the microprocessor
(computer's) memory. Refer to the Computer Programming Manual supplied with dryer
for more specific operating information.
NOTE: The dryer can be stopped at any time by opening main door or by pressing the "CLEAR/
STOP" key. To restart the dryer, press the "ENTER/START" key or preprogrammed
cycle key (i.e., "E").
NOTE: Selection (setting) changes can be made at any time during the drying cycle by pressing
the "CLEAR/STOP" key twice. The L.E.D. display will return to "FILL" at which time
a new cycle selection can be made.
b. Dual Timer Dryers
1) Select Drying Time and Cool Down Time desired...
a) Turn Heat Timer clockwise (CW) to desired time (i.e., 1 minute to 60 minutes).
b) Turn Cool Down Timer clockwise (CW) to desired time (i.e., 0 minutes to 30 minutes).
2) Select Drying Temperature ("HI TEMP," "LO TEMP," or "PERM PRESS").
3) Push "Push to Start" switch...
a) Dryer will now start.
4) To stop dryer, open the main door.
39
Download from Www.Somanuals.com. All Manuals Search And Download.
L. SHUT DOWN INSTRUCTIONS
If the dryer is to be shut down (taken out of service) for a period of time, the following must be performed:
1. Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.
2. GAS MODELS ... discontinue the gas supply.
1) SHUT OFF externalgas supply shut-off valve.
2) SHUT OFF internalgas supply shut-off valve located in the gas valve burner area.
3. STEAM MODELS ... discontinue the steam supply.
1) SHUT OFF steam valves in the supply lines and the return lines.
40
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION IV
SERVICE/PARTS INFORMATION
A. SERVICE
1. Service must be performed by a qualified trained technician, service agency, or gas supplier. If service is
required, contact the distributor from whom the ADC equipment was purchased. If the distributor cannot
be contacted or is unknown, contact the ADC Service Department for a distributor in your area.
NOTE: When contacting the ADC Service Department, be sure to give them the correct model
number and serial number so that your inquiry is handled in an expeditious manner.
B. PARTS
1. Replacement parts should be purchased from the distributor from whom the ADC equipment was
purchased. If the distributor cannot be contacted or is unknown, contact the ADC Parts Department for a
distributor in your area. Parts may also be purchased directly from the factory by calling the ADC Parts
Department at (508) 678-9010 or you may FAX in your order at (508) 678-9447.
NOTE: When ordering replacement parts from the ADC dealer or the ADC factory be sure to
give them the correct model number and serial number so that your parts order can be
processed in an expeditious manner.
41
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION V
WARRANTY INFORMATION
A. RETURNING WARRANTY CARD(S)
1. Before any dryer leaves theADC factory test area, a warranty card (ADC Part No. 112254) is placed on
the back side of the main door glass. These warranty cards are intended to serve the customer
where we record the individual installation date and warranty information to better serve you should
you file a warranty claim.
a. If a warranty card (ADC Part No. 112254) did not come with your dryer, contact the ADC
Warranty Department or ADC Service Department at (508) 678-9000.
IMPORTANT: A separate warranty card must be completed and returned for each individual
dryer.
NOTE: Be sure to include the installation date when returning the warranty card(s).
B. WARRANTY
For a copy of the ADC commercial warranty covering your particular dryer(s), contact the ADC distributor
from whom you purchased the equipment and request dryer warranty form ADC Part No. 450199. If the
distributor cannot be contacted or is unknown, warranty information can be obtained from the factory by
contacting the ADC Warranty Department at (508) 678-9000.
NOTE: Whenever contacting the ADC factory for warranty or warranty information, be sure to
have the dryer's model number and serial number available so that your inquiry can be
handled in an expeditious manner.
C. RETURNING WARRANTY PARTS
ALL dryer or parts warranty claims or inquiries should be addressed to the ADC Warranty Parts Department.
To expedite processing, the following procedures must be followed:
1. No parts are to be returned to ADC without prior written authorization ("Return Material Authorization")
from the factory.
NOTE: An R.M.A. ("Return Material Authorization") is valid for only sixty (60) days from
date of issue.
a. The R.M.A. issued by the factory, as well as any other correspondence pertaining to the returned part(s),
must be included inside the package with the failed merchandise.
42
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Each part must be tagged with the following information:
a. Model numberand serial numberof the dryer from which part was removed.
b. Nature of failure (be specific).
c. Date of dryer installation.
d. Date of part failure.
e. Specify whether the part(s) being returned is for a replacement, a credit, or a refund.
NOTE: If a part is marked for a credit or a refund, the invoice number covering the purchase
of the replacement part must be provided.
NOTE: Warranty tags (ADC Part No. 450064) are available at "no charge" from ADC upon
request.
3. The company returning the part(s) must clearly note the complete company name and address on the
outside of the package.
4. ALL returns must be properly packaged to insure that they are not damaged in transit.Damage claims are
the responsibility of the shipper.
IMPORTANT: No replacements, credits or refunds will be issued for merchandise damaged in
transit.
5. ALL returns should be shipped to the ADC factory in such a manner that they are insured and a proof
of delivery can be obtained by the sender.
6. Shipping charges are not the responsibility of ADC. ALL returns should be "prepaid" to the
factory. Any "C.O.D." or "COLLECT" returnswill not be accepted.
IMPORTANT: No replacements, credits, or refunds will be issued if the claim cannot be
processed due to insufficient information. The party filing the claim will be
notified in writing, either by "FAX" or "CERTIFIED MAIL - Return Receipt
Requested", as to the information necessary to process claim. If a reply is not
received by the ADC Warranty Department within thirty (30) days from the
FAX/letter date, then no replacement, credit, or refund will be issued, and the
merchandise will be discarded.
43
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION VI
ROUTINE MAINTENANCE
A. CLEANING
A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from
various areas of the dryer, as well as throughout the duct work system. The frequency of cleaning can best be
determined from experience at each location. Maximum operating efficiency is dependent upon proper air
circulation. The accumulation of lint can restrict this air flow. If the guidelines in this section are met, an ADC
dryer will provide many years of efficient, trouble-free, and - most importantly - safe operation.
WARNING: LINT FROM MOST FABRICS IS HIGHLY COMBUSTIBLE. THE
ACCUMULATION OF LINT CAN CREATE A POTENTIAL FIRE
HAZARD.
WARNING: KEEP DRYER AREA CLEAR AND FREE FROM COMBUSTIBLE
MATERIALS, GASOLINE, and OTHER FLAMMABLE VAPORS and
LIQUIDS.
NOTE: Suggested time intervals shown are for average usage which is considered six (6) to
eight (8) operational (running) hours per day.
Clean the lint drawer/screen every third or fourth load.
NOTE: Frequency can best be determined at each location.
SUGGESTED CLEANING SCHEDULE
DAILY (beginning of each work shift)
1. Clean lint from screen.
2. Inspect lint screen and replace if torn.
WEEKLY
Clean lint accumulation from lint chamber, thermostat, and microprocessor temperature sensor (sensor bracket)
area.
WARNING: TO AVOID THE HAZARD OF ELECTRICAL SHOCK, DISCONTINUE
ELECTRICAL SUPPLY TO THE DRYER.
44
Download from Www.Somanuals.com. All Manuals Search And Download.
STEAM DRYERS
Clean the steam coil fins. We suggest using compressed air and a vacuum cleaner with brush attachment.
WARNING: When cleaning steam coil fins, be careful not to bend the fins. If fins are bent,
straighten by using a fin comb which is available from local air-conditioning
supply houses.
90 DAYS
Remove lint from around basket (tumbler), drive motors, and surrounding areas. Remove lint from gas
valve burner area with a dusting brush or vacuum cleaner attachment.
NOTE: To prevent damage, avoid cleaning and/or touching ignitor/flame-probe assembly.
Remove lint accumulation from inside control box and at the rear area behind control box.
Impellor (fan/blower) shaft bearings should be lubricated. Use a #3 grease or equivalent.
6 MONTHS
Inspect and remove lint accumulation in customer furnished exhaust duct work system and from dryers
internal exhaust ducting.
Impellor (fan/blower) belts and drive belts should be examined. Cracked and/or seriously frayed belts
should be replaced. Tighten belts when necessary.
WARNING: THE ACCUMULATION OF LINT IN THE EXHAUST DUCT WORK CAN
CREATE A POTENTIAL FIRE HAZARD.
WARNING: DO NOT OBSTRUCT THE FLOW OF COMBUSTION and VENTILATION
AIR. CHECK CUSTOMER FURNISHED BACK DRAFTED DAMPERS IN
EXHAUST DUCK WORK. INSPECT and REMOVE ANY LINT
ACCUMULATION WHICH CAN CAUSE DAMPER TO BIND OR STICK.
NOTE: A back draft damper that is sticking partially closed can result in slow drying and
shutdown of the heat circuit safety switches or thermostats.
NOTE: When cleaning dryer cabinet(s), avoid using harsh abrasives. A product intended for
the cleaning of appliances is recommended.
45
Download from Www.Somanuals.com. All Manuals Search And Download.
B. ADJUSTMENTS
7 Days After Installation and Every 6 Months Thereafter
Inspect bolts, nuts, screws (bearing set screws), non-permanent gas connections (unions, shut-off valves,
orifices, and grounding connections). Motor and drive belts should be examined. Cracked or seriously
frayed belts should be replaced. Tighten loose V-belts when necessary. Complete operational check of
controls and valves. Complete operational check of ALL safety devices (door switch, lint drawer switch,
sail switch, burner and hi-limit thermostats).
C. LUBRICATION
1. Impellor (fan/blower) shaft bearings should be lubricated every (3) months. Use a #3 grease or equivalent.
2. The motor bearings, idler bearings, and tumbler bearings are permanently lubricated.
NO LUBRICATION IS NECESSARY.
46
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION VII
TROUBLESHOOTING
IMPORTANT: YOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPLY and
THE GAS SUPPLY or THE STEAM SUPPLY BEFORE ANY COVERS
or GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS
FOR CLEANING, ADJUSTING, INSTALLATION, or TESTING OF ANY
EQUIPMENT per OSHA (Occupational Safety and Health Administration)
STANDARDS.
The information provided will help isolate the most probable component(s) associated with the difficulty
described. The experienced technician realizes, however, that a loose connection or broken/ shorted wire may
be at fault where electrical components are concerned ... and not necessarily the suspected componentitself.
Electrical parts should always be checked for failure before being returned to the factory.
Theinformation provided should not be misconstrued as a handbook for use by an untrained person making
repairs.
IMPORTANT: When replacing blown fuses, the replacement must be of the exact rating as the
fuse being replaced.
WARNING: ALL SERVICE and TROUBLESHOOTINGSHOULD BE PERFORMEDBYA
QUALIFIED PROFESSIONAL OR SERVICE AGENCY.
WARNING: WHILE MAKING REPAIRS, OBSERVEALL SAFETY PRECAUTIONS
DISPLAYED ON THE DRYER or SPECIFIED IN THIS MANUAL.
MICROPROCESSOR (COMPUTER) MODELS
A. No L.E.D. display (microprocessor [computer] models ONLY) ...
1. Service panel fuse blown or tripped breaker.
2. Blown control circuit L1 or L2 fuse.
3. Failed microprocessor controller (computer).
B. Drive motor not operating (does not start) ...
1. Failed drive motor contactor (relay).
47
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Failed arc suppressor (A.S.) board.
3. Failed drive motor.
4. Failed microprocessor controller (computer).
C. Drive motor (reversing) operates in one direction only ... stops and restarts in same direction ...
1. Failed drive motor contactor (relay).
2. Failed arc suppressor (A.S.) board.
3. Failed microprocessor controller (computer).
D. Drive motor operates okay for a few minutes, and then stops and will not restart ...
1. Motor is overheating and tripping out on internal overload protector ...
a. Motor air vents clogged with lint.
b. Low voltage to the motor.
c. Failed motor.
d. Basket (tumbler) is binding ... check for obstruction.
e. Failed idler bearings or tumbler bearings.
E. Blower motor not operating (does not start) ...
1. Tripped or failed overload protector.
2. Failed blower motor contactor (relay).
3. Failed arc suppressor (A.S.) board.
4. Failed motor.
5. Failed microprocessor controller (computer).
F. Blower motor operates okay for a few minutes, then stops and will not restart ...
1. Motor is overheating and tripping out on internal overload protector ...
a. Motor air vents clogged with lint.
b. Low voltage to the motor.
c. Failed motor.
d. Failed (out of balance) impellor (fan/blower).
48
Download from Www.Somanuals.com. All Manuals Search And Download.
G. Both drive motor and blower motor not operating (do not start) ...
microprocessor controller (computer) motor indicator dots are on ...
1. Failed arc suppressor (A.S.) board.
2. Failed microprocessor controller (computer).
H. Both drive motor and blower motor run a few minutes and then stop...microprocessor controller
(computer) display continues to read time or percent of extraction and all indicator dots are off ...
1. Fault in main door switch circuit ...
a. Failedmaindoorswitch.
b. Main door switch out of adjustment.
c. Loose connection in door switch circuit.
2. Fault in lint drawer switch circuit...
a. Lint drawer switch out of proper adjustment.
b. Loose connection in the lint drawer switch circuit.
I. Microprocessor (computer) display reads "dSFL" ...
1. Fault in microprocessor heat sensing circuit ...
a. Blown 1/8-amp ("dSFL") fuse on microprocessor controller (computer).
b. Failed microprocessor temperature sensor.
c. Failed microprocessor controller (computer).
d.Broken wire or connection somewhere between the microprocessor controller (computer) and the micro
processor temperature sensor.
J. Microprocessor controller (computer) display reads "door" ...
1. Fault (open circuit) in main door or lint drawer switch circuit ...
a. Lint drawer is not closed all the way.
b. Lint drawer switch out of proper adjustment.
c. Failed lint drawer switch.
d.Failedmaindoorswitch.
e. Broken connection / wire in main door or lint drawer circuit.
f. Failed 24 VAC Transformer.
49
Download from Www.Somanuals.com. All Manuals Search And Download.
K. Microprocessor controller (computer) will not accept any keyboard entries, i.e., L.E.D. display
reads "FILL" and when keyboard entries are selected, the L.E.D. display continues to read
"FILL" ...
1. Failed keyboard label (touchpad) assembly.
2. Failed microprocessor controller (computer).
L. Microprocessor controller will only accept certain keyboard entries ...
1. Failed keyboard label (touchpad) assembly.
2. Failed microprocessor controller (computer).
M. Microprocessor controller (computer) locks up and L.E.D. display reads erroneous message(s) or
only partial segments ...
1. Transient power voltage (spikes)...disconnect power to dryer, wait one (1) minute, and reestablish power
to dryer. If problem is still evident ...
a. Failed microprocessor controller (computer).
b. Failed keyboard label (touchpad) assembly.
N. Dryer stops during a cycle and L.E.D. display returns to "FILL" ...
1. Fault in microprocessor heat sensor circuit ...
a. Loose connection in wires between temperature sensor and microprocessor controller (computer).
2. Loose connection somewhere in main power circuit to microprocessor controller (computer).
O. Gas heating unit is not operating (no heat)...no spark at burner area when dryer is first started, and
heat indicator dot is on ...
1. Fault in sail switch circuit ...
a. Sail switch is out of adjustment or has failed.
b. Sail switch damper is not closing or is fluttering ...
1) Lint screen is dirty.
2) Restriction in exhaust.
2. Fault in burner hi-limit circuit or thermostat.
3. Fault in lint chamber sensor bracket hi-heat protector thermostat.
4. Failed Direct Spark Ignition (DSI) module.
5. Failed DSI ignitor / flame-probe assembly.
6. Failed microprocessor controller (computer).
50
Download from Www.Somanuals.com. All Manuals Search And Download.
P. No heat (GAS MODEL ONLY)...ignitor sparks, burner goes on and off right away ...
1. DSI ignitor / flame-probe out of adjustment...reposition closer to the flame area.
2. Sail switch is fluttering ...
a. Lint screen dirty.
b. Restriction in exhaust duct work.
3. Insufficient make-up air.
4. Failed ignitor / flame-probe assembly.
5. Failed Direct Spark Ignition (DSI) module.
6. Failed gas valve.
Q. No heat (for STEAM MODELS ONLY) ...
1. Fault in lint chamber sensor bracket hi-heat (limit) protector thermostat.
2. Failed microprocessor controller (computer).
3. No (external) compressed air to steam damper (80 psi required).
4. Failed steam damper 24 VAC pneumatic solenoid switch.
5. Failedpiston.
6. Steam damper stuck closed.
7. Air flow control valve restricting incoming compressed air.
R. No heat (for ELECTRIC MODELS ONLY) ...
1. Fault in sail switch circuit...
a. Sail switch out of adjustment and/or faulty (failed).
b. Sail switch not closing or fluttering...
1) Check impellor (fan/blower) motor and rotation direction.
2) Restriction in the location exhaust system.
2. Failed oven hi-limit.
3. Failed lint compartment automatic (225º) safety thermostat.
4. Failed oven contactor (relay).
5. Failed microprocessor controller (computer).
51
Download from Www.Somanuals.com. All Manuals Search And Download.
S. Dryer operates but is taking too long to dry ...
1. Exhaust duct work run too long or is undersized...back pressurecannot exceed .3 inches Water Column
(W.C.).
2. Restriction in exhaust ...
a. Exhaust back draft damper is sticking partially closed.
b. Restriction in duct work...check duct work from dryer all the way to the outdoors.
3. Low and/or inconsistent gas pressure(for GAS MODELS ONLY).
4. Insufficient make-up air.
5. Poor air / gas mixture at burner...yellow or poor flame pattern; adjust gas burner air adjustment shutters
(for GAS MODELS ONLY).
6. Lint screen not being cleaned on a regular basis or often enough.
7. Extractors (washers) not performing properly.
8. Sail switch is fluttering...restriction in exhaust(for GAS MODELS ONLY).
9. Failed microprocessor controller (computer)...temperature calibration is inaccurate.
10. Failed microprocessor temperature sensor calibration is inaccurate.
11. Failed burner hi-limit (for GAS MODELS ONLY).
12. Failed lint chamber hi-heat protector thermostat.
13. Steam damper system not functioning properly(for STEAM MODELS ONLY).
a. Steam damper sticking closed.
b. Leak in the pneumatic system.
c. Flow control incorrectly set.
T. Condensation on main door glass ...
1. Too long, undersized, or improperly installed duct work.
2. Dryer connected to common exhaust duct with another dryer and no back draft damper was installed in
customer furnished duct work.
3. Back draft damper is sticking in partially closed position.
52
Download from Www.Somanuals.com. All Manuals Search And Download.
U. Dryer or scraping noise at basket (tumbler) area ...
1. Check for object caught in basket (tumbler) / wrapper area.
2. Basket (tumbler) is out of proper alignment ...
a. Check both vertical and lateral alignment.
b. Check gap between front panel and basket (tumbler) front...set screws may have come loose, and basket
(tumbler)walkedforwardorbackwards.
3. Loose basket (tumbler) tie rod.
4. Failed basket (tumbler) support.
V. Excessive noise and/or vibration ...
1. Dryer not leveled properly.
2. Impellor (fan) out of balance ...
a. Excessive lint build up on impellor (fan/blower).
b. Failed impellor (fan/blower).
3. Loose basket (tumbler) tie rod.
4. Basket out of adjustment, or adjustment bolts (hardware) are loose.
5. Failed basket (tumbler) support.
6. Loosemotormount.
7. Failed idler and/or tumbler bearings.
8. V-belt(s) either too tight or too loose.
TIMERMODELS
A. Dryer will not start. Both drive and blower motors not operating (indicator light is off) ...
1. Dryer control circuit fuse is blown.
2. Open at location...
a. service main fuse or circuit breaker.
3. Failed push to start relay.
4. Failed door switch and/or circuit.
5. Failed heat timer.
6. Failed dual timer relay.
53
Download from Www.Somanuals.com. All Manuals Search And Download.
B. Drive motor (only) not operating (does not start)...
1. Failed drive motor contactor.
2. Failed reversing timer(for Reversing Models ONLY).
3. Failed drive motor.
C. Blower (impellor/fan) motor (only) not operating (does not start)...
1. Tripped or failed overload.
2. Failed impellor (impellor/fan) motor contactor (relay).
3. Failed reversing timer.
4. Failed blower (impellor/fan) motor.
D. Both drive and blower (impellor/fan) motors not operating (do not start) and indicator lightis on...
1. Fault with L1 termination at reversing timer(for Reversing Models ONLY).
E. Reversing drive motor operates in one direction only, stops, and restarts in same direction
(for Reversing Models ONLY) ...
1. Failed reversing contactor (relay).
2. Failed reversing timer.
F. Heating unit not operating (no heat)...no voltage at heating unit (i.e., Gas Model DSI module or
Steam Model damper system pneumatic solenoid)...
GAS MODELS
1. Fault in sail switch circuit ...
a. Sail switch out of adjustment and/or has failed.
b. Sail switch damper is not closing or is fluttering ...
1) Check blower (impellor / fan) motor and rotation direction.
2) Restriction in exhaust.
3) Lint drawer / screen is dirty.
2. Failed burner hi-limit circuit.
3. Failed lint compartment automatic (225º) safety thermostat circuit.
4. Failed Direct Spark Ignition (DSI) Module (burner control).
5. Failed Direct Spark Ignition (DSI) ignitor/flame-probe assembly.
6. Failed heat selector switch.
54
Download from Www.Somanuals.com. All Manuals Search And Download.
ELECTRIC MODELS
1. Fault in sail switch circuit ...
a. Sail switch out of adjustment and/or has failed.
b. Sail switch is not closing or is fluttering ...
1) Check blower (impellor / fan) motor and rotation direction.
2) Restriction in exhaust.
2. Failed oven hi-limit circuit.
3. Failed lint compartment automatic (225º) safety thermostat circuit.
4. Failed oven contactor (relay).
5. Failed heat selector switch.
STEAM MODELS
1. Steam damper binding and/or stuck.
2. No (external) compressed air to the steam damper...80 PSI required.
3. Failed lint compartment automatic (225º) safety thermostat circuit.
4. Failed steam damper 24 VAC pneumatic solenoid switch.
5. Air flow control valve restricting incoming compresses air.
6. Failed heat selector switch.
7. Failed steam damper piston.
G. Heat unit not operating for only one (1) temperature selection ...
1. Failed thermostat corresponding to selection made.
2. Failed heat selector switch
H. Dryer operates but is taking too long to dry load ...
1. Heating unit cycling on hi-limit thermostat(for GAS and ELECTRIC MODELS ONLY).
2. Steam damper binding in partially open position(for STEAM MODELS ONLY).
3. Lint and/or dust accumulation on steam coil fins(for STEAM MODELS ONLY).
4. Housekeeping ...
a. Lint screen and lint compartment not being cleaned on a regular basis.
55
Download from Www.Somanuals.com. All Manuals Search And Download.
b. Lint accumulation in location exhaust system.
5. Insufficient make-up air.
6. Failed hi-limit thermostat (for GAS and ELECTRIC MODELS ONLY).
7. Failed lint compartment automatic (225º) safety thermostat circuit.
8. Extractors not performing properly.
9. Low and/or inconsistent gas pressure (for GAS MODELS ONLY).
10. Gas supply may have low heating value (for GAS MODELS ONLY).
11. Sail switch is fluttering (for GAS and ELECTRIC MODELS ONLY)...
a. Restriction in location exhaust system.
12. Fault in electric oven element circuit (for ELECTRIC MODELS ONLY) ...
a. Failed element(s).
b.Failed oven contactor (relay).
13. Exceptionally cold / humid or low barometric pressure atmosphere.
14. Blower (impellor / fan) motor rotation direction is incorrect.
I. Dryer is cycling on hi-limit thermostat (for GAS and ELECTRIC MODELS ONLY) ...
1. Blower (impellor / fan) motor rotation direction is incorrect.
2. Insufficient make-up air.
3. Restriction in exhaust system ...
a. Undersizedexhaustducting.
4. Lint screen needs cleaning.
5. Failed hi-limit thermostat.
6. Failed oven contactor (relay) -for ELECTRIC MODELS ONLY.
J. Condensation on main door glass...
1. Too long, undersized, or improperly installed duct work.
2. Dryer connected to common exhaust duct with another dryer, and no back draft damper was installed in
customer-furnished duct work.
3. Location furnished back draft damper in duct work is sticking in partially closed position.
56
Download from Www.Somanuals.com. All Manuals Search And Download.
K. Dryer scraping noise at basket (tumbler) area...
1. Check for object caught in basket (tumbler) / wrapper area.
2. Basket (tumbler) is out of proper alignment.
a. Check both vertical alignment and lateral alignment.
b. Check gap between front panel and basket (tumbler) ... set screws may have come loose, and basket
(tumbler) walked forward or back.
3. Loose basket (tumbler) tie rod.
4. Failed basket (tumbler) support.
L. Excessive noise and/or vibration...
1. Dryer is not leveled properly.
2. Impellor (fan/blower) is out of balance.
a. Excessive lint build-up impellor (fan / blower).
b. Failed impellor (fan / blower).
3. Loose basket (tumbler) tie rod.
4. Basket (tumbler) out of adjustment bolts (hardware) are loose.
5. Failed basket (tumbler) support.
6. Loosemotormount.
7. Failed idler bearings or tumbler (basket) bearings.
8. V-belts too loose or too tight.
9. Failed fan (blower) shaft bearings or set screw(s) may be loose.
57
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION VIII
REVERSING TIMER SPIN/DWELL ADJUSTMENTS
Timer models have an electric reversing timer in the electric service box which is located in the upper left rear
area of the dryer.
Both the Dwell (stop) Time and basket (tumbler) Spin Time are adjustable by mode selection switches located
on the electronic timer (as noted in the illustration below).
Timing Legend
Spin Time
Switch Position Number
Time in Seconds*
1
2
3
4
5
30
60
90
120
150
Dwell (Stop) Time
Switch Position Number
Time in Seconds*
1
5
2
6
3
8
4
5
10
12
* Values shown are +/- 1 second.
58
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION X
PROCEDURE FOR FUNCTIONAL CHECK OF
REPLACEMENT COMPONENTS
1. Microprocessor (computer) Board
a. Upon completing installation of the replacement microprocessor (computer) board,
reestablish power to the dryer.
b. Start the drying cycle.
c. Verify that the motor(s) and the heat indicator dots, in the microprocessor (computer) L.E.D.
display are on. (Refer to the illustration below.)
d. Verify that motor(s) heat, and door indicator lights on the back side of the microprocessor (computer
board are lit. (Refer to illustration below.)
59
Download from Www.Somanuals.com. All Manuals Search And Download.
e. Open main door. The dryer must stop and ALL output indicator lights on the back side of the
microprocessor (computer) board must go out.
f. Try to restart the dryer with the main door open.
g. The microprocessor (computer) board's L.E.D. display must read "DOOR."
h. Close the main door and restart the dryer.
i. Functional check of microprocessor (computer) board is complete.
2. Direct Spark Ignition (DSI) System
a. Upon completing installation of the replacement
Direct Spark Ignition (DSI) module, reestablish power
to the dryer.
b. Start the drying cycle.
c. The ignition (DSI) module's L.E.D. indicator will light
"red" for up to approximately 1.5 seconds (pre-purge
time).
d. The module's indicator light will then turn "green." The
gas valve will be energized and the ignitor probe will
spark for approximately 8 seconds. The burner flame
should now be established.
e. With the burner flame on, remove the flame sensor wire
from the FS terminal of the DSI module.
f. The burner flame must shut off and the ignition
module must lock out with the DSI module's indicator
light "red".
g. Stop the drying cycle, with the flame sensor wire still
removed, restart the drying cycle.
h. The ignition module must proceed through the
pre-purge, with the indicator light "red", the ignition
trial time of approximately 8 seconds, with the
indicator light "green", and then proceed to lock out
with the indicator light "red".
i. Functional check of the Direct Spark Ignition (DSI) Module is complete.
1) Replace the flame sensor wire from the FS terminal to the DSI module.
60
Download from Www.Somanuals.com. All Manuals Search And Download.
ADC 112185
1- 07/05/95-100
4* 09/04/96-250
7* 01/19/98-100
2- 07/27/95-250
5* 03/12/97-250
8- 04/16/98-100
3* 03/20/96-250
6- 10/14/97-100
9* 07/17/98-200
10* 03/12/99-100 11- 08/13/99-100 12* 01/03/00-125
13- 05/09/00-125 14- 09/28/00-100
Download from Www.Somanuals.com. All Manuals Search And Download.
|