Alto Shaam Food Warmer HFT2 300 User Manual

H o t F o o d T a b l e  
Merchandiser  
Models:  
HFT2SYS-300  
HFT2-300  
HFT2SYS-400 (Standard)  
HFT2SYS-400  
HFT2-400  
HFT2SYS-500  
HFT2-500  
HFT2-300  
• InstallatIon  
• operatIon  
• MaIntenance  
HFT2SYS-500 (Deluxe)  
W164 N9221 Water Street • P.O. Box 450 • Menomonee Falls, Wisconsin 53052-0450 USA  
PHONE: 262.251.3800 • 800.558.8744 USA/CANADA FAX: 262.251.7067 • 800.329.8744 U.S.A. ONLY  
MN-29506 • 01/12  
p r i n t e d i n u .s .a .  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DeLiVeRy  
uNPACkiNG  
1. Carefully remove the  
appliance from the  
carton or crate.  
This Alto-Shaam appliance has been  
thoroughly tested and inspected to ensure only  
the highest quality unit is provided. Upon  
receipt, check for any possible shipping damage  
and report it at once to the delivering carrier.  
See Transportation Damage and Claims section  
located in this manual.  
®
®
NOte: Do not discard the  
carton and other  
packaging material  
until you have  
This appliance, complete with unattached  
items and accessories, may have been delivered  
in one or more packages. Check to ensure that all  
standard items and options have been received  
with each model as ordered.  
inspected the unit  
for hidden damage  
and tested it for  
proper operation.  
2. Read all instructions in this manual carefully  
Save all the information and instructions  
packed with the appliance. Complete and return  
the warranty card to the factory as soon as  
possible to ensure prompt service in the event of a  
warranty parts and labor claim.  
before initiating the installation of this appliance.  
DO NOT DISCARD THIS MANUAL.  
This manual is considered to be part of the  
appliance and is to be provided to the owner  
or manager of the business or to the person  
responsible for training operators. Additional  
manuals are available from the Alto-Shaam  
Tech Team Service Department.  
This manual must be read and understood  
by all people using or installing the equipment  
model. Contact the Alto-Shaam Tech Team Service  
Department if you have any questions concerning  
installation, operation, or maintenance.  
3. Remove all protective plastic film, packaging  
materials, and accessories from the appliance  
before connecting electrical power. Store any  
accessories in a convenient place for future use.  
NOte: All claims for warranty must include the  
full model number and serial number of  
the unit.  
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 1.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
sAFety PROCeDuRes  
AND PReCAutiONs  
Knowledge of proper procedures is essential to the  
safe operation of electrically and/or gas energized  
equipment. In accordance with generally accepted  
product safety labeling guidelines for potential  
hazards, the following signal words and symbols  
may be used throughout this manual.  
1. This appliance is intended to hold foods  
for the purpose of human consumption.  
No other use for this appliance is authorized  
or recommended.  
2. This appliance is intended for use in commercial  
establishments where all operators are  
familiar with the purpose, limitations, and  
associated hazards of this appliance. Operating  
instructions and warnings must be read and  
understood by all operators and users.  
DANGeR  
Used to indicate the presence of  
a hazard that WILL cause severe  
personal injury, death, or substantial  
property damage if the warning  
included with this symbol is ignored.  
3. Any troubleshooting guides, component views,  
and parts lists included in this manual are for  
general reference only and are intended for use  
by qualified technical personnel.  
WARNiNG  
4. This manual should be considered a permanent  
part of this appliance. This manual and all  
supplied instructions, diagrams, schematics,  
parts lists, notices, and labels must remain with  
the appliance if the item is sold or moved to  
another location.  
Used to indicate the presence of a  
hazard that CAN cause personal injury,  
possible death, or major property  
damage if the warning included with  
this symbol is ignored.  
CAutiON  
NOte  
Used to indicate the presence of a  
hazard that can or will cause minor or  
moderate personal injury or property  
damage if the warning included with  
this symbol is ignored.  
For equipment delivered for use  
in any location regulated by the  
following directive:  
DO NOT DISPOSE OF ELECTRICAL  
OR ELECTRONIC EQUIPMENT WITH  
OTHER MUNICIPAL WASTE.  
CAutiON  
Used to indicate the presence of a hazard that  
can or will cause minor personal injury, property  
damage, or a potential unsafe practice if the  
warning included with this symbol is ignored.  
NOte: Used to notify personnel of  
installation, operation, or  
maintenance information that is  
important but not hazard related.  
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 2.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
iNstALLAtiON  
site iNstALLAtiON  
DANGeR  
alteRatiOn, adJUStment,  
SeRviCe, OR maintenanCe COUld  
ReSUlt in SeveRe inJURY, deatH,  
OR CaUSe pROpeRtY damage.  
CAutiON  
impROpeR inStallatiOn,  
tO pRevent peRSOnal inJURY,  
USe CaUtiOn WHen mOving OR  
leveling tHiS applianCe.  
Read tHe inStallatiOn,  
OpeRating and maintenanCe  
inStRUCtiOnS tHOROUgHlY  
beFORe inStalling OR SeRviCing  
tHiS eQUipment.  
CAutiON  
The performance of this unit has  
been optimized using the factory  
provided bulbs. These bulbs should  
be replaced with an exact replacement  
or with a factory recommended  
CAutiON  
replacement. These bulbs have been  
treated to resist breakage and must be  
replaced with similarly treated bulbs in  
order to maintain compliance with NSF  
standards. DO NOT over-tighten bulbs  
in their receptacles as this can cause  
damage to the bulb filament.  
metal paRtS OF tHiS eQUipment  
beCOme eXtRemelY HOt WHen  
in OpeRatiOn. tO avOid bURnS,  
alWaYS USe Hand pROteCtiOn  
WHen OpeRating tHiS applianCe.  
site iNstALLAtiON  
In order to maintain  
A number of adjustments are associated with  
initial installation and start-up. It is important  
that these adjustments be conducted by a  
qualified service technician. Installation and  
start-up adjustments are the responsibility of the  
dealer or user. These adjustments include but  
are not limited to thermostat calibration, door  
adjustment, leveling, electrical hook-up and  
installation of optional casters or legs.  
®
established National  
Sanitation Foundation  
standards, all stationary  
floor models must be  
sealed to the floor with a  
R.T.V. or silastic meeting  
N.S.F. requirements or  
have 6" (153mm)  
unobstructed clearance  
beneath the unit.  
1. The appliance must be  
installed on a stable  
and level surface.  
2. DO NOT install this appliance in any area  
where it may be affected by any adverse  
conditions such as steam, grease, dripping water,  
high temperatures, or any other severely  
adverse conditions.  
LeVeLiNG  
Level the appliance from side-to-side and  
front-to-back with the use of a spirit level.  
3. DO NOT install a heated display case near a cold  
air source such as a freezer, air conditioning vents,  
or in any area where outside air fluctuation can  
affect performance.  
We recommend checking the level periodically  
to make certain the floor has not shifted nor the  
appliance moved.  
NOte: Failure to properly level this appliance  
4. This appliance must be kept free and clear of  
any obstructions blocking access for  
maintenance or service.  
can cause improper function.  
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 3.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
iNstALLAtiON  
site iNstALLAtiON  
HFT2-300  
6-13/16"  
(173mm)  
Tray Slide  
9-13/16"  
(248mm)  
To Well  
20-1/8" (512mm)  
13" (331mm)  
To Elec.  
4-1/8"  
(104mm)  
To Elec.  
20-1/8" (509mm)  
26-1/8" (663mm)  
39-3/4" (1008mm)  
43-13/16" (1113mm)  
48" (1220mm)  
HFT2SYS-300 (Standard)  
20-1/8"  
(512mm)  
Well  
1-5/16"  
(34mm)  
9-13/16"  
(248mm)  
Reach  
TOP VIEW  
9-1/4" (233mm)  
Shelf Width  
8" (203mm)  
Shelf Width  
48" (1220mm)  
20-1/8"  
(509mm)  
26-1/8"  
42-5/8" (1081mm)  
48" (1220mm)  
(663mm)  
39-3/4" (1008mm)  
HFT2SYS-300 (Deluxe)  
67" (1701mm)  
39-3/4" (1008mm)  
9"  
(228mm)  
10-1/2"  
(267mm)  
Shelf Width  
42-5/8" (1081mm)  
49-1/16" (1246mm)  
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 4.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
iNstALLAtiON  
site iNstALLAtiON  
HFT2-300 (230V, International, with Bumper)  
34-3/8" (872mm)  
7/8"  
(21mm)  
4-1/8"  
(105mm)  
To Elec.  
13" (331mm)  
To Elec.  
48" (1220mm)  
38" (964mm)  
Well  
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 5.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
iNstALLAtiON  
site iNstALLAtiON  
HFT2-400  
20-1/8"  
(512mm)  
6-13/16"  
(173mm)  
Tray Slide  
9-13/16"  
(248mm)  
To Well  
13" (331mm)  
To Elec.  
4-1/8"  
20-1/8" (509mm)  
(104mm)  
To Elec.  
26-1/8" (663mm)  
39-3/4" (1008mm)  
27-15/16" (709mm)  
27-15/16" (709mm)  
60" (1525mm)  
20-1/8"  
(512mm)  
Well  
HFT2SYS-400 (Standard)  
9-13/16"  
(248mm)  
Reach  
TOP VIEW  
9-1/4" (233mm)  
Shelf Width  
8" (203mm)  
Shelf Width  
59-7/16" (1509mm)  
54-5/8" (1386mm)  
60" (1525mm)  
20-1/8"  
(509mm)  
26-1/8"  
(663mm)  
39-3/4" (1008mm)  
HFT2SYS-400 (Deluxe)  
39-3/4" (1008mm)  
79-1/8" (2009mm)  
9"  
(228mm)  
10-1/2"  
(267mm)  
Shelf Width  
54-5/8" (1386mm)  
61-1/16" (1551mm)  
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 6.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
iNstALLAtiON  
site iNstALLAtiON  
HFT2-500  
6-13/16"  
(173mm)  
Tray Slide  
9-13/16"  
(248mm)  
To Well  
20-1/8"  
(512mm)  
4-1/8"  
(104mm)  
To Elec.  
13" (331mm)  
33-15/16" (861mm)  
To Elec.  
72" (1830mm)  
33-15/16" (861mm)  
20-1/8"  
(509mm)  
26-1/8" (663mm)  
39-3/4" (1008mm)  
HFT2SYS-500 (Standard)  
20-1/8"  
(512mm)  
Well  
64-1/8" (1628mm)  
Well  
9-13/16"  
(248mm)  
Reach  
6-9/16"  
166 mm  
To Elec.  
TOP VIEW  
9-1/4" (233mm)  
Shelf Width  
8" (203mm)  
Shelf Width  
71-7/16" (1814mm)  
Top Surface  
20-1/8"  
(509mm)  
26-1/8"  
66-5/8" (1690mm)  
72" (1830mm)  
(663mm)  
39-3/4" (1008mm)  
HFT2SYS-500 (Deluxe)  
91" (2311mm)  
39-3/4" (1008mm)  
9"  
(228mm)  
10-1/2"  
(267mm)  
Shelf Width  
66-5/8" (1690mm)  
73-1/8" (1856mm)  
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 7.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
iNstALLAtiON  
capacities • options  
PRODuCt/PAN CAPACity -  
Based on 4" (65mm) deep pans  
HFT2-300, HFTSYS-300  
OPtiONs AND ACCessORies  
D4: 62 lb (30 kg) max.  
max. volume: D4: 45 qt (57 L)  
Panel Color Choices  
see service parts  
FULL-SIZE PANS*: Three (3) 12" x 20" x 4"  
Pan Dividers, Full Size  
16019  
GN 1/1 (325mm x 530mm x 102mm)  
HALF-SIZE PANS*: Six (6) 12" x 10" x 4"  
GN 1/2 (325mm x 265mm x 102mm)  
THIRD-SIZE PANS*: Nine (9) 12" x 6" x 4"  
GN 1/3 (325mm x 176mm x 102mm)  
Pan Dividers, Half and Third Size  
11318  
*will also accept 2-1/2" (65mm) deep paNs; d6 uNits will accept 6" (153mm) deep pans  
HFT2-400, HFTSYS-400  
96 lb (44 kg) maximum  
max. volume: 60 qt (76 L)  
FULL-SIZE PANS*: Four (4) 12" x 20" x 4"  
GN 1/1 (325mm x 530mm x 102mm)  
HALF-SIZE PANS*: Eight (8) 12" x 10" x 4"  
GN 1/2 (325mm x 265mm x 102mm)  
THIRD-SIZE PANS*: Twelve (12) 12" x 6" x 4"  
GN 1/3 (325mm x 176mm x 102mm)  
*will also accept 2-1/2" (65mm) deep paNs; d6 uNits will accept 6" (153mm) deep pans  
HFT2-500, HFTSYS-500  
120 lb (54 kg) maximum  
max. volume: 75 qt (95 L)  
FULL-SIZE PANS*: Five (5) 12" x 20" x 4"  
GN 1/1 (325mm x 530mm x 65mm)  
HALF-SIZE PANS*: Ten (10) 12" x 10" x 4"  
GN 1/2 (325mm x 265mm x 65mm)  
THIRD-SIZE PANS*: Fifteen (15) 12" x 6" x 4"  
GN 1/3 (325mm x 176mm x 65mm)  
*will also accept 2-1/2" (65mm) deep paNs; d6 uNits will accept 6" (153mm) deep pans  
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 8.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
iNstALLAtiON  
eLeCtRiCAL CONNeCtiON  
The appliance must be installed by a qualified  
service technician. The oven must be properly  
grounded in accordance with the National  
Electrical Code and applicable local codes.  
DANGeR  
eleCtRiCal COnneCtiOnS mUSt  
be made bY a QUaliFied SeRviCe  
teCHniCian in aCCORdanCe WitH  
appliCable eleCtRiCal COdeS.  
DANGeR  
to avoid electrical shock, this  
appliance mUSt be adequately  
grounded in accordance with local  
electrical codes or, in the absence of  
local codes, with the current edition  
of the national electrical Code anSi/  
nFpa no. 70. in Canada, all electrical  
connections are to be made in  
DANGeR  
enSURe pOWeR SOURCe  
matCHeS vOltage Stamped  
On applianCe nameplate.  
accordance with CSa C22.1, Canadian  
electrical Code part 1 or local codes.  
REGARDING INTERNATIONAL  
STANDARD UNITS:  
If the unit is not equipped with flexible cord with  
plug, an all-pole country approved disconnection  
device which has a contact separation of at least  
3mm in all poles must be incorporated in the fixed  
wiring for disconnection. When using a cord  
without a plug, the green/yellow conductor shall  
be connected to the terminal which is marked with  
the ground symbol. If a plug is used, the socket  
outlet must be easily accessible. If the power cord  
needs replacement, use a similar one obtained  
from the distributor.  
Plug the unit into a properly grounded receptacle  
ONLY, positioning the unit so that the plug is  
easily accessible in case of an emergency. Arcing  
will occur when connecting or disconnecting the  
unit unless all controls are in the “off” position.  
Proper receptacle or outlet configuration or  
permanent wiring for this unit must be installed  
by a licensed electrician in accordance with  
applicable local electrical codes.  
eLeCtRiCAL - HFt2-300  
voltage  
phase cycle/hz amps  
kW  
corD & plug  
208-240 (agcy)  
at 208  
1
1
1
60  
60  
60  
13.6 3.3  
11.8 2.5  
13.6 3.3  
NEMA 6-15P  
For CE approved units: To prevent an electrical  
shock hazard between the appliance and other  
appliances or metal parts in close vicinity, an  
equalization-bonding stud is provided. An  
equalization bonding lead must be connected to  
this stud and the other appliances / metal parts  
to provide sufficient protection against potential  
difference. The terminal is marked  
15A - 250V Plug  
at 240  
230  
1
50  
13.0 3.0  
cee 7/7,  
220-230v plug  
eLeCtRiCAL - HFt2-400  
voltage  
phase cycle/hz amps  
kW  
corD & plug  
208-240 (agcy)  
at 208  
1
1
1
60  
60  
60  
13.7 3.3  
11.9 2.5  
13.7 3.3  
NEMA 6-20P  
with the following symbol.  
20A - 250V Plug  
at 240  
230  
1
50  
13.1 3.0  
cee 7/7,  
220-230v plug  
eLeCtRiCAL - HFt2-500  
voltage  
phase cycle/hz amps  
kW  
corD & plug  
208-240 (agcy)  
at 208  
1
1
1
60  
60  
60  
15.7 3.8  
13.6 2.8  
15.7 3.8  
NEMA 6-20P  
20A - 250V Plug  
at 240  
230  
1
50  
15.0 3.5  
cee 7/7,  
220-230v plug  
Wire diagrams are included in the literature  
package supplied with the unit.  
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 9.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPeRAtiON  
useR sAFety iNFORm AtiON  
useR sAFety iNFORmAtiON:  
CAutiON  
This appliance is intended for use in commercial  
establishments by qualified personnel who are  
familiar with the purpose, limitations, and associated  
hazards of this appliance. Operating instructions  
and warnings must be read and understood by all  
operators and users.  
metal paRtS OF tHiS eQUipment  
beCOme eXtRemelY HOt WHen  
in OpeRatiOn. tO avOid bURnS,  
alWaYS USe Hand pROteCtiOn  
WHen OpeRating tHiS applianCe.  
stARt uP  
BeFORe iNitiAL use:  
Before operating the unit, clean both the interior and  
exterior of the unit with a damp cloth and mild soap  
solution. Rinse well.  
DANGeR  
DisCONNeCt uNit FROm  
POWeR sOuRCe BeFORe  
CLeANiNG OR seRViCiNG.  
Merchandiser heat plate must be heated to remove  
surface oils and the accompanying odor produced  
during the first use of the appliance.  
Turn ON/OFF toggle switch to ON position. Turn  
thermostat to the 10 setting. Allow the unit to heat  
for 30 minutes or until no odor is detected.  
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 10.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPeRAtiON  
OPeRAtiNG iNstRuCtiONs  
1. DO NOt ADD WAteR tO HOt WeLL  
All pan divider bars required must be utilized  
at all times with the pan configuration chosen.  
Before loading food into the unit, use a pocket-  
type thermometer to make certain all products  
have reached an internal temperature of  
140° to 180°F (60° to 82°C). If any food product  
is not at proper serving temperature, use a Halo  
Heat cooking and holding oven, set at 250° to 275°F  
(121° to 135°C), or a Combitherm oven to bring the  
product within the correct temperature range.  
Halo Heat® hot wells maintain a constant  
and gentle temperature. Adding water is not  
recommended since water will accelerate the  
deterioration of the product and may damage the  
unit voiding the warranty.  
2. PLACe PAN DiViDeRs AND emPty  
PANs iN tHe WeLLs  
NOte: No matter what type of pan configuration  
chosen, pan separator bars or divider bars must  
be used to close all gaps between pans, and all  
gaps between the pans and the edges of the wells.  
If these gaps are not closed, heat will escape,  
heat distribution will be uneven, and uniform  
temperature will be difficult to maintain.  
6. Reset tHeRmOstAt(s) As NeeDeD  
After all products are loaded into the unit, it  
is necessary to reset the thermostat(s). Since  
proper temperature range depends on the type  
of products and the quantities being held,  
it is necessary to periodically use a pocket  
thermometer to check each item to make certain  
the correct temperatures are being maintained.  
Proper temperature range is between a minimum  
of 140° and 180° F (60° and 82° C).  
This is a VERY important requirement to follow  
whenever this appliance is in use.  
3. tuRN POWeR sWitCH “ON”  
Turn toggle switch to “ON” position. Lights will  
illuminate and hot well will begin to warm.  
7. tO mAiNtAiN PROPeR FOOD  
temPeRAtuRe, OVeRHeAD HeAtiNG  
is RequiReD.  
4. PReHeAt At tHe NumBeR “10” settiNG  
FOR A miNimum OF 30 miNutes  
An indicator light will illuminate  
when the thermostat(s) is (are)  
turned “ON.” The unit should be  
preheated at the 10 setting for a  
minimum of 30 minutes before  
loading the unit with hot food.  
CAutiON  
metal paRtS OF tHiS eQUipment  
beCOme eXtRemelY HOt WHen  
in OpeRatiOn. tO avOid bURnS,  
alWaYS USe Hand pROteCtiOn  
WHen OpeRating tHiS applianCe.  
5. LOAD HOt FOODs iNtO tHe APPLiANCe  
8. seRVe FResH, HOt FOOD  
After preheating, place hot foods into the  
preheated pans located in the appliance or  
exchange the pans with pre-filled product pans.  
This appliance is designed for the purpose of hot  
food holding. Only hot foods should be placed  
into the unit. Potentially hazardous foods should  
be held in the unit at setting 10. If lower settings  
are used, ensure the food has maintained safe  
food temperatures. Lower settings should be  
tested by user to ensure food has maintained  
safe food temperatures between 140° and 160°F  
(60° and 71°C).  
Keep hot foods looking fresh. Occasionally stir or  
rotate food as needed. Wipe spills immediately to  
ensure maximum eye appeal and to ease end of  
day cleanup.  
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 11.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPeRAtiON  
GeNeRAL HOLDiNG GuiDeLiNes  
Chefs, cooks and other specialized food service  
personnel employ varied methods of cooking. Proper  
holding temperatures for a specific food product must  
be based on the moisture content of the product, product  
density, volume, and proper serving temperatures. Safe  
holding temperatures must also be correlated with  
palatability in determining the length of holding time for a  
specific product.  
HOLDiNG tem PeRAtuRe RANGe  
meAt  
BEEF ROAST — Rare  
BEEF ROAST — Med/Well Done  
FAHReNHeit  
CeLsius  
130°F  
54°C  
155°F  
68°C  
BEEF BRISKET  
CORN BEEF  
PASTRAMI  
160° — 175°F  
160° — 175°F  
160° — 175°F  
130°F  
71° — 79°C  
71° — 79°C  
71° — 79°C  
54°C  
PRIME RIB — Rare  
STEAKS — Broiled/Fried  
RIBS — Beef or Pork  
VEAL  
140° — 160°F  
160°F  
60° — 71°C  
71°C  
Halo Heat maintains the maximum amount of product  
moisture content without the addition of water, water  
vapor, or steam. Maintaining maximum natural product  
moisture preserves the natural flavor of the product and  
provides a more genuine taste. In addition to product  
moisture retention, the gentle properties of Halo Heat  
maintain a consistent temperature throughout the cabinet  
without the necessity of a heat distribution fan, thereby  
preventing further moisture loss due to evaporation  
or dehydration.  
160° — 175°F  
160° — 175°F  
160° — 175°F  
160° — 175°F  
71° — 79°C  
71° — 79°C  
71° — 79°C  
71° — 79°C  
HAM  
PORK  
LAMB  
POuLtRy  
CHICKEN — Fried/Baked  
DUCK  
160° — 175°F  
160° — 175°F  
160° — 175°F  
160° — 175°F  
71° — 79°C  
71° — 79°C  
71° — 79°C  
71° — 79°C  
TURKEY  
GENERAL  
FisH/seAFOOD  
FISH — Baked/Fried  
LOBSTER  
160° — 175°F  
160° — 175°F  
160° — 175°F  
71° — 79°C  
71° — 79°C  
71° — 79°C  
When product is removed from a high temperature  
cooking environment for immediate transfer into  
SHRIMP — Fried  
BAkeD GOODs  
equipment with the lower temperature required for hot  
food holding, condensation can form on the outside of  
the product and on the inside of plastic containers used in  
self-service applications. Allowing the product to release  
the initial steam and heat produced by high temperature  
cooking can alleviate this condition. To preserve the safety  
and quality of freshly cooked foods however, a maximum  
of 1 to 2 minutes must be the only time period allowed for  
the initial heat to be released from the product.  
BREADS/ROLLS  
120° — 140°F  
49° — 60°C  
misCeLLANeOus  
CASSEROLES  
DOUGH — Proofing  
EGGS —Fried  
FROZEN ENTREES  
HORS D'OEUVRES  
PASTA  
160° — 175°F  
80° — 100°F  
150° — 160°F  
160° — 175°F  
160° — 180°F  
160° — 180°F  
160° — 180°F  
180°F  
71° — 79°C  
27° — 38°C  
66° — 71°C  
71° — 79°C  
71° — 82°C  
71° — 82°C  
71° — 82°C  
82°C  
PIZZA  
POTATOES  
PLATED MEALS  
SAUCES  
140° — 165°F  
140° — 200°F  
140° — 200°F  
160° — 175°F  
60°— 74°C  
60° — 93°C  
60° — 93°C  
71° — 79°C  
Use a metal-stemmed thermometer to measure the  
internal temperature of the product being held. Adjust the  
thermostat setting to achieve the best overall setting based  
on internal product temperature.  
SOUP  
VEGETABLES  
THE HOLDING TEMPERATURES LISTED ARE SUGGESTED GUIDELINES ONLY. ALL  
FOOD HOLDING SHOULD BE BASED ON INTERNAL PRODUCT TEMPERATURES.  
ALWAYS FOLLOW LOCAL HEALTH (HYGIENE) REGULATIONS FOR ALL INTERNAL  
TEMPERATURE REQUIREMENTS.  
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 12.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CARe AND CLeANiNG  
CLeANiNG AND PReVeNtiVe m AiNteNANCe  
PROteCtiNG stAiNLess steeL suRFACes  
CLeANiNG AGeNts  
It is important to guard against corrosion  
in the care of stainless steel  
Use non-abrasive cleaning products designed for  
use on stainless steel surfaces. Cleaning agents  
must be chloride-free compounds and must not  
contain quaternary salts. Never use hydrochloric  
acid (muriatic acid) on stainless steel surfaces.  
Always use the proper cleaning agent at the  
manufacturer's recommended strength.  
surfaces. Harsh, corrosive,  
or inappropriate chemicals  
can completely destroy the  
protective surface layer  
of stainless steel. Abrasive  
pads, steel wool, or metal implements will abrade  
surfaces causing damage to this protective coating  
and will eventually result in areas of corrosion.  
Even water, particularly hard water that contains  
high to moderate concentrations of chloride, will  
cause oxidation and pitting that result in rust  
and corrosion. In addition, many acidic foods  
spilled and left to remain on metal surfaces are  
contributing factors that will corrode surfaces.  
Contact your local cleaning supplier for  
product recommendations.  
CLeANiNG mAteRiALs  
The cleaning function can usually be accomplished  
with the proper cleaning agent and a soft, clean  
cloth. When more aggressive methods must be  
employed, use a non-abrasive scouring pad on  
difficult areas and make certain to scrub with the  
visible grain of surface metal to avoid surface  
scratches. Never use wire brushes, metal scouring  
pads, or scrapers to remove food residue.  
Proper cleaning agents, materials, and  
methods are vital to maintaining the appearance  
and life of this appliance. Spilled foods should be  
removed and the area wiped as soon as possible  
but at the very least, a minimum of once a day.  
Always thoroughly rinse surfaces after using a  
cleaning agent and wipe standing water as quickly  
as possible after rinsing.  
CAutiON  
tO pROteCt StainleSS Steel  
SURFaCeS, COmpletelY avOid  
tHe USe OF abRaSive Cleaning  
COmpOUndS, CHlORide baSed  
CleaneRS, OR CleaneRS  
COntaining QUateRnaRY SaltS.  
neveR USe HYdROCHlORiC aCid  
(mURiatiC aCid) On StainleSS  
Steel. neveR USe WiRe  
bRUSHeS, metal SCOURing  
padS OR SCRapeRS.  
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 13.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CARe AND CLeANiNG  
equiPmeNt CARe  
5. Clean heat guards with a window cleaner.  
6. To help maintain the protective film coating on  
polished stainless steel, clean the exterior of the  
unit with a cleaner recommended for stainless  
steel surfaces. Spray the cleaning agent on a cloth  
and wipe with the grain of the stainless steel.  
The cleanliness and appearance  
of this equipment will contribute  
considerably to operating  
efficiency and savory,  
appetizing food.  
Good equipment that is kept clean works better and  
lasts longer.  
Always follow appropriate state or local health  
(hygiene) regulations regarding all applicable  
cleaning and sanitation requirements for  
foodservice equipment.  
tHOROuGHLy CLeAN tHe  
APPLiANCe DAiLy  
1. Remove food from merchandiser.  
DANGeR  
2. Turn ON/OFF toggle switch to  
the “OFF” position. Disconnect unit from power  
source. Let the unit cool.  
at nO time SHOUld tHe inteRiOR  
OR eXteRiOR be Steam Cleaned,  
HOSed dOWn, OR FlOOded WitH  
WateR OR liQUid SOlUtiOn OF  
anY Kind. dO nOt USe WateR Jet  
tO Clean.  
3. Clean heat plate and metal surfaces of the  
unit with a damp, clean cloth and any good  
commercial detergent at the recommended  
strength. Use a plastic scouring pad or oven  
cleaner for difficult areas. Rinse surfaces by  
wiping with sponge and clean warm water  
seVeRe DAmAGe OR  
eLeCtRiCAL HAZARD  
COuLD ResuLt.  
WaRRantY beCOmeS vOid iF  
applianCe iS FlOOded  
NOte: Avoid the use of abrasive cleaning,  
compounds, chloride based cleaners, or  
cleaners containing quaternary salts. Never  
use hydrochloric acid (muriatic acid) on  
stainless steel.  
DANGeR  
4. Surfaces can be wiped with a sanitizing solution  
after cleaning and rinsing. This solution must  
be approved for use on stainless steel food  
contact surfaces.  
DisCONNeCt uNit FROm  
POWeR sOuRCe BeFORe  
CLeANiNG OR seRViCiNG.  
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 14.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
sANitAtiON  
Food flavor and aroma are usually so closely related that  
The most accurate method of measuring safe temperatures  
of both hot and cold foods is by internal product  
temperature. A quality thermometer is an effective tool for  
this purpose, and should be routinely used on all products  
that require holding at a specific temperature.  
it is difficult, if not impossible, to separate them. There  
is also an important, inseparable relationship between  
cleanliness and food flavor. Cleanliness, top operating  
efficiency, and appearance of equipment contribute  
considerably to savory, appetizing foods. Good equipment  
that is kept clean, works better and lasts longer.  
A comprehensive sanitation program should focus on  
the training of staff in basic sanitation procedures. This  
includes personal hygiene, proper handling of raw foods,  
cooking to a safe internal product temperature, nd the  
routine monitoring of internal temperatures from receiving  
through service.  
Most food imparts its own particular aroma and many  
foods also absorb existing odors. Unfortunately, during  
this absorption there is not distinction between GOOD  
and BAD odors The majority of objectionable flavors and  
odors troubling food service operations are caused by  
bacteria growth. Sourness, rancidity, mustiness, stale or  
other OFF flavors are usually the result of germ activity.  
Most food-borne illnesses can be prevented through  
proper temperature control and a comprehensive  
program of sanitation. Both these factors are important  
to build quality service as the foundation of customer  
satisfaction. Safe food handling practices to prevent food-  
borne illness is of critical importance to the health and  
safety of your customers.  
The easiest way to insure full, natural food flavor is  
through comprehensive cleanliness. This means good  
control of both visible soil (dirt) and invisible soil  
(germs). A through approach to sanitation will provide  
essential cleanliness. It will assure an attractive  
appearance of equipment, along with maximum efficiency  
and utility. More importantly, a good sanitation program  
provides one of the key elements in the prevention of  
food-borne illnesses.  
HACCP, an acronym for Hazard Analysis (at) Critical  
Control Points, is a quality control program of operating  
procedures to assure food integrity, quality, and safety.  
Taking steps necessary to augment food safety practices  
is both cost effective and relatively simple. While HACCP  
guidelines go far beyond the scope of this manual,  
additional information is available by contacting:  
A controlled holding environment for prepared foods is  
just one of the important factors involved in the prevention  
of food-borne illnesses. Temperature monitoring and  
control during receiving, storage, preparation, and the  
service of foods are of equal importance.  
CenteR FOR FOOd SaFetY and applied  
nUtRitiOn FOOd and dRUg adminiStRatiOn  
1-888-SaFeFOOd  
INTERNAL FOOD PRODUCT TEMPERATURES  
HOT FOODS  
40° TO 140°F  
70° TO 120°F  
140° TO 165°F  
DANGER ZONE  
CRITICAL ZONE  
SAFE ZONE  
(4° TO 60°C)  
(21° TO 49°C)  
(60° TO 74°C)  
COLD FOODS  
ABOVE 40°F  
36° TO 40°F  
DANGER ZONE  
SAFE ZONE  
(ABOVE 4°C)  
(2° TO 4°C)  
FROZEN FOODS  
ABOVE 32°F  
0° TO 32°F  
DANGER ZONE  
CRITICAL ZONE  
SAFE ZONE  
(ABOVE 0°C)  
(-18° TO 0°C)  
0°F or below  
(-18°C or below)  
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 15.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
seRViCe  
seRViCe PARts  
mODeL >  
HFt2-300  
HFt2-400  
HFt2-500  
item  
DesCRiPtiON  
PARt NO. qty  
PARt NO. qty  
PARt NO. qty  
1
2
3
4
5
6
LExAn GUARD  
GD-29516  
ST-2547  
GD-29413  
1012070  
LG-2044  
5011297  
1010949  
1010952  
BM-29064  
2
12  
2
GD-29517  
ST-2547  
GD-29413  
1012070  
LG-2044  
2
12  
2
GD-29412  
ST-2547  
GD-29413  
1012070  
LG-2044  
2
12  
2
SHOULDER STUD, LOnG S/S  
LExAn GUARD, FULL SIDE  
SIDE PAnEL, S/S  
2
2
2
LEGS, 4" (102mm) ADjUSTABLE (CT OnLY)  
BUMPER (230V InT’L OnLY)  
— BUMPER TRACK  
4
4
4
2
2
— BUMPER RAIL  
2
— BUMPER EnD CAP  
4
2
1
3
6
5
4
tRAy sLiDes  
mODeL >  
DesCRiPtiON  
HFt2-300  
PARt NO. qty  
HFt2-400  
PARt NO. qty  
HFt2-500  
PARt NO. qty  
item  
1
2
TRAY SLIDE, SPOT  
5013497  
SC-2425  
2
5013542  
SC-2425  
2
5013486  
SC-2425  
2
SCREW, PHIL, 8-32 x 1/2"  
12  
16  
16  
1
2
Part numbers and drawings are  
subject to change without notice.  
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 16.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
seRViCe  
seRViCe PARts List - PANeL COLORs, BAskets  
mODeL >  
HFt2-300  
PARt NO.  
HFt2-400  
PARt NO.  
HFt2-500  
PARt NO.  
item  
DesCRiPtiON  
PAnEL, EnD, PAInTED - STAnDARD  
STAInLESS STEEL  
qty  
qty  
qty  
1
1006498  
1006499  
1006497  
1006498  
1006499  
1006497  
1006498  
1006499  
1006497  
2
2
2
BLACK  
SPECIFY CUSTOM COLOR  
PAnEL, EnD, PAInTED - COUnTER-TOP  
STAInLESS STEEL  
1012070  
1012069  
1012071  
1012070  
1012069  
1012071  
1012070  
1012069  
1012071  
2
2
1
2
2
2
1
2
2
2
1
2
BLACK  
SPECIFY CUSTOM COLOR  
PAnEL, EnD, FORMICA - DELUxE  
BLACK  
PE-28241  
PE-27805  
PE-28241  
PE-27805  
PE-28241  
PE-27805  
SPECIFY CUSTOM COLOR  
2
3
CAnOPY TOP COVER, OUTER  
STAInLESS STEEL  
5005294  
5005285  
5005295  
5013547  
5013544  
5013548  
5007920  
5007449  
5007450  
BLACK  
SPECIFY CUSTOM COLOR  
SHELF, STAnDARD/DELUxE  
STAInLESS STEEL  
BLACK  
5006786  
5006851  
5006852  
5013550  
5013549  
5013551  
5007615  
5007616  
5007971  
CUSTOM COLOR  
4
5
RIVET  
RI-2100  
5006642  
BS-27896  
1006624  
1007795  
nU-24613  
SC-22307  
SC-22466  
24  
4
RI-2100  
5013563  
BS-27896  
1006624  
1007795  
nU-24613  
SC-22307  
SC-22466  
24  
4
RI-2100  
5007638  
BS-27896  
1006624  
1007795  
nU-24613  
SC-22307  
SC-22466  
24  
4
SHELF, WOOD - DELUxE OnLY  
BASKET, WOOD - DELUxE OnLY  
HOLDER 1, SIDE BASKET  
HOLDER 2, SIDE BASKET  
nUT, InSERT, THREADED  
SCREW, CT, M4.8 x 16MM  
SCREW, 1/4-20 x 1 PHIL  
6
2
2
2
7
2
2
2
8*  
9*  
10*  
11*  
2
2
2
8
8
8
8
8
8
8
8
8
*nOT SHOWn  
2
7
1
6
5
3
4
1
3
Part numbers and drawings are  
subject to change without notice.  
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 17.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
seRViCe  
HFt2-400 shown  
13  
25  
26  
1
14  
12  
8
27  
24  
3
9
27  
29 30  
7
2
31  
14  
22  
20  
1
13  
19  
23  
4
26  
21  
16  
17  
4
31  
19  
20  
5
17  
16  
10  
18  
6
27  
11  
Part numbers and drawings are  
subject to change without notice.  
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 18.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
seRViCe  
seRViCe PARts List - CORe uNit  
HFt2-500  
mODeL >  
HFt2-300  
HFt2-400  
item  
DesCRiPtiON  
InnER TOP LIGHT EnD  
PARt NO. qty  
PARt NO. qty  
PARt NO. qty  
1
2
1007098  
1007507  
1008952  
1012113  
1012185  
1007110  
1007080  
1012196  
1008316  
5013467  
4880  
2
1
1007098  
1007507  
1008952  
1012113  
1012185  
1012222  
1012223  
1012224  
1012226  
5013526  
4881  
2
1
1007098  
1007507  
1008952  
1012113  
1008952  
1008268  
1008327  
1011896  
1008330  
5012935  
4880  
2
1
TERMInAL BRACKET HOLDER  
RECEPTACLE LOCK  
3
12  
1
16  
2
16  
2
4
COnTROL ATTACHMEnT PLATE  
EnD LExAn POSITIOn CLIP  
BOTTOM COVER PAnEL  
InnER TOP SIDE  
5
4
4
16  
1
6
1
1
7
1
1
1
8
InnER TOP COnTROL SIDE  
InnER LIGHT PAnEL  
WELL EnCLOSURE, SPOT  
ELEMEnT KIT  
1
1
1
9
1
1
1
10  
11  
12  
13  
14  
15*  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32*  
1
1
1
1
1
1
InnER TOP SPOT  
5005806  
BK-3019  
BU-33619  
HG-27333  
In-2003  
1
5013538  
BK-3019  
BU-33619  
HG-27333  
In-2003  
1
5007446  
BK-3019  
BU-33619  
HG-27333  
In-2003  
1
T-BLOCK  
2
2
2
BUSHInG, 1" HOLE  
4
4
5
HInGE, UPRIGHT SUPPORT  
2
2
2
InSULATIOn, BOARD, 5.875 x 21.670, 1/2"  
InSULATIOn, BOARD, 6 x 50.125, 1/2"  
InSULATIOn, FLUFF  
2
2
2
In-2003  
2
In-2003  
2
In-2003  
2
In-22364  
Kn-26568  
LI-3951  
1
In-22364  
Kn-26568  
LI-3951  
1
In-22364  
Kn-26568  
LI-3951  
1
KnOB, THERMOSTAT  
1
2
2
PILOT LIGHT, WHITE  
1
2
2
LAMP, FLOOD  
LP-33783  
PE-29421  
RI-2100  
6
LP-33783  
PE-29421  
RI-2100  
8
LP-33783  
PE-29421  
RI-2100  
8
PAnEL OVERLAY  
1
2
2
RIVET, BLInD #44, STnLS  
RECEPTACLE, SnAP In  
12  
6
20  
8
12  
8
RP-3955  
SC-2190  
SC-2365  
SC-2459  
SC-26791  
SW-3528  
SW-3905  
TT-34981  
RP-3955  
SC-2190  
SC-2365  
SC-2459  
SC-26791  
SW-3528  
SW-3905  
TT-34981  
RP-3955  
SC-2190  
SC-2365  
SC-2459  
SC-26791  
SW-3528  
SW-3905  
TT-34981  
SCREW, GROUnD 10-32 x 1/4 PAn HD  
SCREW, 6-32 x 1-1/4 ROUnD HD  
SCREW, 8-32 x 1/4 PHIL  
2
2
2
4
4
4
62  
12  
1
68  
12  
2
74  
12  
1
SCREW, 10-32 x 1/4 PAn HEAD  
SWITCH, 20A, 250V, TOGGLE SWITCH  
SWITCH, RUBBER BOOT W/ nUT  
THERMOSTAT, 240V, 13A  
1
2
1
1
2
2
CORDSET  
208-240V  
230V  
CD-33840  
CD-3922  
1
1
CD-3588  
CD-3922  
1
1
CD-3588  
CD-3922  
1
1
33*  
34*  
35*  
BUSHInG, STRAIn RELIEF  
POWER SWITCH  
BU-3964  
SW-3528  
5012929  
2
1
1
BU-3964  
SW-3528  
5012929  
2
1
1
BU-3964  
SW-3528  
5012929  
2
1
1
GROUnD STUD, 230V OnLY  
*nOT SHOWn  
DANGeR  
DisCONNeCt uNit FROm  
POWeR sOuRCe BeFORe  
CLeANiNG OR seRViCiNG.  
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 19.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
seRViCe  
HFt2-400 Base shown  
2
6
10  
4
4
1
3
7
A
1
12  
8
13  
9
5
7
1
14  
A
Part numbers and drawings are  
subject to change without notice.  
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 20.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
seRViCe  
seRViCe PARts List - BAse  
mODeL >  
HFt2-300  
HFt2-400  
HFt2-500  
item  
DesCRiPtiON  
CORD COVER PLATE  
PARt NO.  
qty  
PARt NO.  
qty  
PARt NO.  
qty  
1
2
3
4
5
1006591  
1006995  
5005235  
5013483  
BK-3019  
2
1
1
2
1
1006591  
1012228  
5013540  
5013541  
BK-3019  
2
1
1
2
1
1006591  
1008348  
5007460  
5012923  
BK-3019  
2
1
1
2
1
BASE STAnD TOP PAnEL  
BASE SUPPORT SPOT  
BASE STIFFEnER, SPOT  
T-BLOCK  
CORDSET  
208-240V  
230V  
CD-33840  
CD-3922  
1
1
CD-3588  
CD-3922  
1
1
CD-3588  
CD-3922  
1
1
6*  
7
8
CASTER, RIGID 5" (127mm)  
CS-2025  
CS-2026  
PG-3559  
RI-2100  
2
2
CS-2025  
CS-2026  
PG-3559  
RI-2100  
2
2
CS-2025  
CS-2026  
PG-3559  
RI-2100  
2
2
CASTER, SWIVEL 5" (127mm) WITH BRAKE  
PLUG, 7/8" HOLE  
9
1
1
1
10  
11*  
12  
13  
14  
15*  
RIVET, BLInD, #44, STnLS  
3/8-16 x 1-1/2" HEx CAP  
72  
6
64  
6
72  
6
SC-22553  
SC-2351  
SC-2365  
SC-2425  
WS-23991  
SC-22553  
SC-2351  
SC-2365  
SC-2425  
WS-23991  
SC-22553  
SC-2351  
SC-2365  
SC-2425  
WS-23991  
5/16-18 x 5/8" SERR. HEx HD SCREW  
6-32 x 1-1/4" ROUnD HD  
16  
2
16  
2
16  
2
8-32 x 1/2" PHIL SCREW  
8
8
8
3/8" ID 7/8" OD S/S FLAT WASHER  
6
6
6
*nOT SHOWn  
Cable Heating ReplaCement SeRviCe KitS  
Kit nUmbeR >  
HFt2-300  
4880  
HFt2-400  
4881  
HFt2-500  
5 4880  
SeRviCe Kit inClUdeS:  
CB-3045 CaBle Heating element  
CR-3226 Ring ConneCtoR  
132 ft  
144 ft  
12  
120 ft  
8
8 ft  
8
8
8 ft  
8
in-3488  
insulation CoRneR  
8 ft  
12  
Bu-3105 sHouldeR BusHing  
Bu-3106 Cup BusHing  
8
12  
8
sl-3063  
ta-3540  
st-2439  
insulating sleeve  
HigH temp eleCtRiCal tape  
10.32 stud  
8
12  
8
1 roll  
8
1 roll  
12  
1 roll  
8
nu-2215 Hex nut  
32  
24  
32  
DANGeR  
CALiBRAtiON  
enSURe pOWeR SOURCe  
CALiBRAtiON PROCeDuRes  
matCHeS vOltage Stamped  
On applianCe nameplate.  
Every unit is calibrated at the factory. Only a qualified  
service technician should calibrate the unit in the field  
if necessary.  
sHOCk Risk WARNiNG: Unit must be disconnected  
from power source before making adjustments or  
calibrating switch.  
CAutiON  
tHiS SeCtiOn iS pROvided FOR tHe aSSiStanCe  
OF QUaliFied SeRviCe teCHniCianS OnlY and  
iS nOt intended FOR USe bY UntRained OR  
UnaUtHORiZed SeRviCe peRSOnnel.  
tOOLs RequiReD: 2mm allen (hex) wrench  
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 21.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 22.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HFT2 INSTALLATION/OPERATION/SERVICE MANUAL • 23.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TRANSPORTATION DAMAGE and CLAIMS  
All Alto-Shaam equipment is sold F.O.B. shipping point, and when accepted by the carrier, such shipments  
become the property of the consignee.  
Should damage occur in shipment, it is a matter between the carrier and the consignee. In such cases,  
the carrier is assumed to be responsible for the safe delivery of the merchandise, unless negligence can be  
established on the part of the shipper.  
1. Make an immediate inspection while the equipment is still in the truck or immediately after it is moved to the receiving area.  
Do not wait until after the material is moved to a storage area.  
2. Do not sign a delivery receipt or a freight bill until you have made a proper count and inspection of all merchandise received.  
3. Note all damage to packages directly on the carrier’s delivery receipt.  
4. Make certain the driver signs this receipt. If he refuses to sign, make a notation of this refusal on the receipt.  
5. If the driver refuses to allow inspection, write the following on the delivery receipt:  
Driver refuses to allow inspection of containers for visible damage.  
6. Telephone the carrier’s office immediately upon finding damage, and request an inspection. Mail a written confirmation of the  
time, date, and the person called.  
7. Save any packages and packing material for further inspection by the carrier.  
8. Promptly file a written claim with the carrier and attach copies of all supporting paperwork.  
We will continue our policy of assisting our customers in collecting claims which have been properly filed and actively pursued.  
We cannot, however, file any damage claims for you, assume the responsibility of any claims, or accept deductions in payment  
for such claims.  
LIMITED WARRANTY  
Alto-Shaam, Inc. warrants to the original purchaser only that any original part that is found to be defective in material or workmanship will, at  
Alto-Shaam's option, subject to provisions hereinafter stated, be replaced with a new or rebuilt part.  
The parts warranty period is as follows:  
For the refrigeration compressor on Alto-Shaam Quickchillers, five (5) years from the date of installation.  
For the heating element on Halo Heat® cooking and holding ovens, as long as the original purchaser owns the oven. This  
excludes holding only equipment.  
For all other parts, one (1) year from the date of installation or fifteen (15) months from the shipping date, whichever occurs first.  
The labor warranty period is one (1) year from the date of installation or fifteen (15) months from the shipping date, whichever occurs first.  
Alto-Shaam will bear normal labor charges performed during standard business hours, excluding overtime, holiday rates or any  
additional fees.  
To be valid, a warranty claim must be asserted during the applicable warranty period. This warranty is not transferable.  
THIS WARRANTY DOES NOT APPLY TO:  
1. Calibration.  
2. Replacement of light bulbs, door gaskets, and/or the replacement of glass due to damage of any kind.  
3. Equipment damage caused by accident, shipping, improper installation or alteration.  
4. Equipment used under conditions of abuse, misuse, carelessness or abnormal conditions, including but not limited to, equipment  
subjected to harsh or inappropriate chemicals, including but not limited to, compounds containing chloride or quaternary salts, poor water  
quality, or equipment with missing or altered serial numbers.  
5. Damage incurred as a direct result of poor water quality, inadequate maintenance of steam generators and/or surfaces affected by water  
quality. Water quality and required maintenance of steam generating equipment is the responsibility of the owner/operator.  
6. Damage caused by use of any cleaning agent other than Alto-Shaam's Combitherm® Cleaner, including but not limited to damage due to  
chlorine or other harmful chemicals. Use of Alto-Shaam's Combitherm® Cleaner on Combitherm® ovens is highly recommended.  
7. Any losses or damage resulting from malfunction, including loss of product, food product, revenue, or consequential or incidental  
damages of any kind.  
8. Equipment modified in any manner from original model, substitution of parts other than factory authorized parts, removal of any parts  
including legs, or addition of any parts.  
This warranty is exclusive and is in lieu of all other warranties, express or implied, including the implied warranties of merchantability and  
fitness for a particular purpose. In no event shall Alto-Shaam be liable for loss of use, loss of revenue or profit, or loss of product, or for any  
indirect, special, incidental, or consequential damages. No person except an officer of Alto-Shaam, Inc. is authorized to modify this warranty  
or to incur on behalf of Alto-Shaam any other obligation or liability in connection with Alto-Shaam equipment.  
Effective November 1, 2011  
RECORD THE MODEL AND SERIAL NUMBER OF THE APPLIANCE FOR EASY REFERENCE.  
ALWAYS REFER TO BOTH MODEL AND SERIAL NUMBER IN ANY CONTACT WITH ALTO-SHAAM REGARDING THIS APPLIANCE.  
Model: ______________________________________________ Date Installed: ______________________________________________________  
Voltage: ______________________________________________ Purchased From: ___________________________________________  
Serial Number: _____________________________________________________________________________________________________________  
G
G
G
W164 N9221 Water Street P.O. Box 450 Menomonee Falls, Wisconsin 53052-0450 U.S.A.  
PHONE: 262.251.3800 • 800.558-8744 USA/CANADA FAX: 262.251.7067 • 800.329.8744 U.S.A. ONLY  
PRINTED IN U.S.A.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Acclaim Lighting Camera Accessories ACCLAIM USB ONLY INTRAORAL DIGITAL VIDEO CAMERA SYSTEM User Manual
ADC Switch ASX User Manual
Aigo MP3 Player UM F158 User Manual
Air King Vacuum Cleaner CVCK1535 User Manual
Alpine Car Stereo System IVA C800E User Manual
Alpine Stereo Amplifier cda 9805 User Manual
Altinex Stereo Amplifier DA1506RT User Manual
Amana Refrigerator W10316638A User Manual
AMX Stereo System DAS T0804 SIG User Manual
Apple Network Card Video Card User Manual