Altinex Stereo Amplifier DA1506RT User Manual

DISTRIBUTION AMPLIFIERS  
MANUAL PART NUMBER: 400-0016-004  
DA1506RT  
2-IN, 6-OUT VGA  
DISTRIBUTION AMPLIFIER  
USER’S GUIDE  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DISTRIBUTION AMPLIFIERS  
PRECAUTIONS / SAFETY WARNINGS  
1
·
·
Do not pull any cables that are attached to the  
DA1506RT.  
Please read this manual carefully before using your  
DA1506RT Distribution Amplifier. Keep this manual  
handy for future reference. These safety  
instructions are to ensure the long life of your  
DA1506RT and to prevent fire and shock hazards.  
Please read them carefully and heed all warnings.  
If the DA1506RT is not used for an extended  
period, disconnect the power cord.  
1.4 CLEANING  
·
·
Unplug the DA1506RT before cleaning.  
Clean only with a dry cloth. Never use strong  
detergents or solvents such as alcohol or  
thinner. Do not use a wet cloth or water to clean  
the unit. Do not open the unit to clean.  
1.1 GENERAL  
·
Qualified ALTINEX service personnel or its  
authorized representatives must perform all  
service.  
1.4 FCC NOTICE  
1.2. RACK-MOUNTING SAFETY GUIDELINES  
·
This device complies with Part 15 of the FCC  
Rules. Operation is subject to the following two  
conditions: (1) This device may not cause  
harmful interference, and (2) this device must  
accept any interference received, including  
interference that may cause undesired  
operation.  
·
The maximum operating ambient temperature  
for this unit is 35°C.  
·
Distribute units evenly inside the rack.  
Hazardous conditions may be created by an  
uneven weight distribution.  
·
·
Connect the unit to a properly rated circuit.  
Reliable grounding should be maintained.  
·
This equipment has been tested and found to  
comply with the limits for a Class A digital device  
pursuant to Part 15 of the FCC Rules. These  
limits are designed to provide reasonable  
protection against harmful interference when the  
1.3 HANDLING  
·
·
For best results, place the DA1506RT on a flat,  
level surface in a dry area away from dust and  
moisture.  
equipment is operated in  
a
commercial  
environment. This equipment generates, uses,  
and can radiate radio frequency energy and if  
not installed and used in accordance with the  
instruction manual, may cause harmful  
interference to radio communications. Operation  
of this equipment in a residential area is likely to  
cause harmful interference in which case the  
user will be required to correct the interference  
at his own expense.  
To prevent fire or shock, do not expose this unit  
to water or moisture. Do not place the  
DA1506RT in direct sunlight, near heaters or  
heat-radiating appliances, or near any liquid.  
Exposure to direct sunlight, smoke, or steam can  
harm internal components.  
·
·
Handle the DA1506RT carefully. Dropping or  
jarring can damage internal components.  
·
Any changes or modifications to the unit not  
expressly approved by ALTINEX, Inc. could void  
the user’s authority to operate the equipment.  
Do not place heavy objects on top of the  
DA1506RT. If the DA1506RT is to be mounted  
to a table or wall, use only ALTINEX-made  
mounting accessories.  
·
To turn off the main power, be sure to remove  
the power cord. The power outlet should be  
installed as near to the equipment as possible,  
and should be easily accessible.  
400-0016-004  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
DISTRIBUTION AMPLIFIERS  
ABOUT YOUR DA1506RT  
2
MECHANICAL  
Material  
DA1506RT  
0.1” Al  
DA1506RT  
2-In, 6-Out Distribution Amplifier (DA)  
Finish  
Gray  
1.75 in (44mm)  
8.50 in (216mm)  
4.50 in (114mm)  
2.0 lb (0.91 kg)  
10°C-35°C  
Height (inches)  
Width (inches)  
Depth (inches)  
Weight (pounds)  
T° Operating  
T° Maximum  
Humidity  
The DA1506RT is a 2-In, 6-Out VGA through  
UXGA distribution amplifier (DA). It is designed to  
connect 1 of 2 computer video sources to as many  
as 6 monitors, displays, and projectors.  
The rear panel of the DA1506RT has 1 computer  
input and 6 outputs, while the front panel has a  
single input. If both the front and rear inputs have  
valid video signals, the image from the front panel  
will be displayed on the 6 outputs. The rear input  
can be permanently connected for normal operation  
and the front panel input can be saved for special  
applications. For example, a desktop PC is  
permanently connected to the rear panel along with  
the display devices. The image from a second  
source, like a laptop, may be connected to the front  
panel and temporarily override the desktop’s  
image. The DA1506DT will automatically switch to  
the front panel’s image.  
50°C  
90% non-condensing  
40,000 hrs  
MTBF (calculations)  
Table 2. DA1506RT Mechanical  
ELECTRICAL  
DA1506RT  
Input Video Signal  
Analog Signal  
1.5 Vp-p max  
75 ohms  
Impedance  
Input Sync Signal  
Horiz/Vert/Composite Sync  
Sync on Green  
Impedance  
TTL(+/-)  
-0.3V  
Though primarily designed for use with displays  
using 15-pin HD (VGA-type) connectors, the  
DA1506RT can pass RGBHV, RGBS, and RGsB  
format signals using adapter cables. The  
DA1506RT is great for desktop use, but can also  
be rack-mounted using optional ALTINEX  
hardware.  
10 kohms  
Output Video Signals  
Analog Signal  
0 dB +/-0.5 dB  
75 ohm  
Impedance  
Output Sync Signal  
Horiz/Vert/Composite Sync  
Sync on Green  
Impedance  
TECHNICAL SPECIFICATIONS  
3
TTL(+/-)  
-0.3 V  
75 ohms  
DC  
Specifications are subject to change.  
See www.altinex.com for up-to-date information.  
FEATURES/  
DA1506RT  
Coupling  
DESCRIPTION  
Power  
GENERAL  
Input Connectors  
Output Connectors  
15-pin HD female (2)  
External adapter (included)  
Total Power  
9 VDC 500 mA  
2.5W max.  
15-pin HD female (6)  
VGA through UXGA,  
RGBHV, RGBS,  
Table 3. DA1506RT Electrical  
Compatibility  
RGsB, and RsGsBs  
Table 1. DA1506RT General  
400-0016-004  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
DISTRIBUTION AMPLIFIERS  
PRODUCT DESCRIPTION  
4
FRONT VIEW  
INPUT1  
INPUT2  
REAR VIEW  
OUTPUTS 1-6  
POWER  
APPLICATION DIAGRAMS  
DIAGRAM 1: TYPICAL SETUP  
5
DA1506RT  
400-0016-004  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
DISTRIBUTION AMPLIFIERS  
DIAGRAM 2: INTERNAL VIEW  
2-IN 6-OUT VGA-XGA DA  
OUT 1  
PLUG AND PLAY  
PLUG AND PLAY  
AUTO SWITCH  
OUT 2  
OUT 3  
OUT 4  
OUT 5  
OUT 6  
FRONT  
BACK  
15-PIN HD  
15-PIN HD  
SIGNAL  
DETECT  
POWER  
POWER  
9V, 0.5A  
PS  
400-0016-004  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
DISTRIBUTION AMPLIFIERS  
DIAGRAM 3: CONNECTOR PINOUTS  
INPUT CONNECTORS  
OUTPUT CONNECTORS  
Pin No.  
PIN ASSIGNMENTS  
Red  
Pin No.  
PIN ASSIGNMENTS  
1
2
1
2
Red  
Green  
Green  
3
Blue  
3
Blue  
4
Ground  
4
No Connection  
Ground  
5
Ground  
5
6
Ground  
6
Ground  
7
Ground  
7
Ground  
8
Ground  
8
Ground  
9
VESA +5V IN  
Ground  
9
+5V  
10  
11  
12  
13  
14  
15  
10  
11  
12  
13  
14  
15  
Ground  
Ground  
No Connection  
No Connection  
Horizontal Sync  
Vertical Sync  
No Connection  
VESA SDA  
Horizontal Sync  
Vertical Sync  
VESA SCL  
Table 4. The DA1506RT Input Pins  
Table 5. The DA1506RT Output Pins  
400-0016-004  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
DISTRIBUTION AMPLIFIERS  
INSTALLING YOUR DA1506RT  
6
TROUBLESHOOTING GUIDE  
8
Step 1. Plug the power adapter into an AC  
We have carefully tested and found no problems in  
the supplied DA1506RT; however, we would like to  
offer suggestions for the following:  
receptacle.  
Step 2. Connect the power to the unit. The power  
indicator LEDs on the front and back  
panels will turn on and red. This indicates  
that the unit is operational.  
·
·
·
Please make sure that the input amplitude of  
analog signal is less than 1.5 Vp-p.  
Please use the ALTINEX-supplied external  
adapter (9V, 500mA).  
Step 3. Connect a VGA-type cable from a  
computer to Input 2 on the amplifier’s rear  
panel. The LEDs will remain red, but the  
images will be present on the output  
connectors.  
Please make sure that proper quality of cables is  
used. We recommend ALTINEX-made cables  
for best results.  
·
If a problem arises after continuous usage at  
higher voltage, higher temperature, higher  
humidity, or at other extreme environmental  
conditions, please make the necessary  
adjustments for the DA1506RT to function safely  
and properly.  
Step 4. Connect a VGA-type cable from another  
PC or laptop to Input 1 on the amplifier’s  
front panel. If there is a signal present on  
Input 1, then the LEDs will turn green  
indicating that Input 1’s image is the  
image present on the output connectors.  
Step 5. Connect the output connectors of the  
amplifier to your display devices:  
monitors, projectors, LCDs, etc.  
ALTINEX POLICIES  
9
9.1 LIMITED WARRANTY/RETURN POLICIES  
Step 6. If the image is less than perfect, check all  
of the connections. Poor quality cables  
may often degrade the performance of the  
product. Make sure that the cables used  
are coaxial cables and that all pins are in  
good condition.  
Please see the ALTINEX website at  
www.altinex.com for details on warranty and  
return policies.  
9.2 CONTACT INFORMATION  
ALTINEX, Inc.  
592 Apollo Street  
OPERATION  
7
Brea, CA 92821 USA  
TEL: 714 990-2300  
There are no adjustments necessary to operate the  
unit. The DA1506RT will operate successfully as  
long as cables are attached properly and other  
technical specifications are followed.  
TOLL FREE: 1-800-ALTINEX  
400-0016-004  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  

3Com TV Receiver 5101M MGT User Manual
Agilent Technologies Stud Sensor E9300 User Manual
Aiphone Intercom System AN 8050DSW User Manual
Aiphone Intercom System IB NA User Manual
Alliance Laundry Systems Washer CFD14C User Manual
American Dryer Corp Clothes Dryer AD 530HS User Manual
American Standard Outdoor Shower 3838Y1DT User Manual
ATON Switch DHSIP User Manual
Banner Stereo Amplifier MA3 4 User Manual
Banner Stud Sensor P4 BCR User Manual