PB - 2200 Pro Series
User’s Manual
Rev. Original
FCC Notes:
This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions manual, may cause interference
to radio communications. It has been tested and found to comply with limits for a Class
A digital device pursuant to subpart J of Part 15 of FCC Rules, which are designed to
provide reasonable protection against interference when operated in a commercial
environment. Operation of this equipment in a residential area is likely to cause
interference in which case the user at his own expense will be required to take whatever
measures to correct the interference.
Warranty Limits:
Warranty terminates automatically when any person other than the authorized
technicians opens the machine. The user should consult his/her dealer for the problem
happened. Warranty voids if the user does not follow the instructions in application of
this merchandise. The manufacturer is by no means responsible for any damage or
hazard caused by improper application.
About This Manual:
Posiflex has made every effort for the accuracy of the content in this manual. However,
Posiflex will assume no liability for any technical inaccuracies or editorial or other
errors or omissions contained herein, nor for direct, indirect, incidental, consequential
or otherwise damages, including without limitation loss of data or profits, resulting
from the furnishing, performance, or use of this material.
This information is provided “as is” and Posiflex Inc. expressly disclaims any
warranties, expressed, implied or statutory, including without limitation implied
warranties of merchantability or fitness for particular purpose, good title and against
infringement.
The information in this manual contains only essential hardware concerns for general
user and is subject to change without notice. Posiflex reserves the right to alter product
designs, layouts or drivers without notification. The system integrator shall provide
applicative notices and arrangement for special options utilizing this product. The user
may find the most up to date information of the hardware from web sites:
All data should be backed-up prior to the installation of any drive unit or storage
peripheral. Posiflex will not be responsible for any loss of data resulting from the use,
disuse or misuse of this or any other Posiflex product.
All rights are strictly reserved. No part of this documentation may be reproduced,
stored in a retrieval system, or transmitted in any form or by any means, electronic,
mechanical, photocopying, or otherwise, without prior express written consent from
Posiflex Inc. the publisher of this documentation.
© Copyright Posiflex Inc. 2006
All brand and product names and trademarks are the property of their respective holders.
Part 1
P/N: 14430900010
Download from Www.Somanuals.com. All Manuals Search And Download.
BRIEF INTRODUCTION
THE USER’S MANUAL
The purpose of this manual is to guide the user in the initial
installation and general use of the Posiflex PB-2200 Pro series of POS
terminals. It does not explain any application software that may be supplied
with it.
We intend to provide our customers with all technology advantages
available by evolving the product design to incorporate appropriate changes
and improvements. So some detail differences may exist between this manual
and the equipment supplied.
For more detailed or technical information please refer to the CD-
ROM disc associated or consult our authorized dealers or visit our web site:
THE PRODUCT
The Posiflex range of PB-2200 Pro terminals have been designed and
manufactured to meet the high end demand on POS systems. It incorporates all
the advances of PC technology within a rugged housing designed for use in a
hostile retail environment. By providing an integrated design, it has retained
many of the secure features of a traditional ECR and has avoided the wiring
“spaghetti” associated with more traditional PC solutions. This Open Standard
Architecture ensures that this terminal can use the PC application software and
development tools that are now inexpensively available and abundant.
The terminal may be used as a self-content unit or as one of several
terminals in a network system controlled by a “back office” computer through
the integrated network interface. Versatile options besides the basic model
selection can apply to it too.
There are various options applicable internally including an UPS
battery and Pole mount VFD customer display through powered COM port or
CF memory card reader. The external options cover even much wider range
including: Monitor, Wireless LAN, Cash drawer, POS printer, Bar code
scanner, Programmable keyboard etc.
THE BASIC MODELS
•
•
PB-2200 –
HT-4200 –
Part 3
Download from Www.Somanuals.com. All Manuals Search And Download.
THE STANDARD FEATURES
CPU: VIA C7 1 GHz; HDD: 40 GB or above; RAM: 256 MB DDR2
upgradeable to 2 GB max.
Ethernet Networking: The standard network port works with both 10 Base T
and 100 Base T.
Serial Ports: There are 4 serial ports in a PB-2200 Pro system. COM1 is
shared by the direct driven cash drawer port and the UPS function. Each COM
port is capable of providing independently a +5 V DC or a +12 V DC supply.
All these DC supplies are achieved through internal jumper setting and they
are all defaulted to give no DC supply at delivery.
Parallel Port: Each PB system is equipped with a parallel port that supports
SPP/EPP/ECP.
VGA Port: There is a VGA connector for connection of external monitor with
+ 12 V DC power supply potential through jumper setting change included.
CR Port: Capable of controlling 2 cash drawers through use of optional cable.
USB Ports: The PB-2200 Pro series is equipped with 6 USB type A
connectors for connection of USB (Universal Serial Bus) devices.
Modem Ring-Up, LAN Or Alarm Wake-Up: The PB series can be turned on
automatically upon an incoming COM port Modem call or LAN status or data
packet received on LAN or a preset time/day/week/month.
UPS function: to support the system from intermittent power failure (battery
itself is an option)
Accidental power off protection – The power switch is safely located at one
side, and this power switch can be defined as a “ON” switch only through
software command.
THE OPTIONAL ITEMS
Note: Underlined items below must be installed prior to delivery from factory.
Attempt to apply them by end users is either too difficult or is likely to cause
damages. Italic items below are stand alone peripheral devices.
a) DRAM Memory Expansion: Upgrade up to 2GB max. in 2 DDR2
modules.
b) 2nd HDD: 2.5” IDE interface
c) Compact Flash Memory Card Slot: Type I
d) Audio Amplifier and Internal Speaker: This option can be available
only in systems equipped with PCI riser card of revision C or later.
e) Customer display: Pole mount 2 x 20 VFD display
f) Wireless LAN Adaptor: inside back cable cover, IEEE 802.11b/g
g) Preload OS: Win 2000, Win XP pro or WEPOS.
h) LCD monitor: 12.1” LM-7112 without touch panel or TM-7112 with
touch panel. Both support further options of BC-300, SD-300 or KP-
210.
Part 4
Download from Www.Somanuals.com. All Manuals Search And Download.
i)
UPS Battery: 2.3 AH 12V lead acid maintenance free battery
j) 2-in-1 Cash Drawer Control Cable: Cable CCBLA-238, when added
to the CR port of the PB series, can be used to control two Posiflex
printer drive type cash drawers.
k) Cash drawer: Printer (Direct) drive type Posiflex cash drawers. Model
numbers coded as CR-3100, CR-3200, CR-4000, CR-4210 or CR-6210
l)
Programmable Keyboard: Various types of Posiflex programmable
keyboards. Most recommended: KB-6000, KB-6200 series or KB-6600.
m) Bar Code Scanner: Short range type (near contact) or long range type
(250 mm for CD-3830) CCD scanners.
n) POS printer: Posiflex 9 pin dot matrix impact printer or Posiflex
thermal printer of RS232 serial interface, parallel interface, USB
interface, LAN interface or even wireless interface.
SYSTEM BOX CONTENTS
When you receive the system box you will find it contains several items:
ꢀPB-2200 Pro system unit
ꢀThis user’s manual
ꢀRecovery CD for preloaded OS or Posiflex Product Information CD
for driver utilities without OS
ꢀOptional components installed to system unit as ordered
ꢀPower adaptor with power cord (1 set)
Part 5
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION GUIDES
IMPORTANT
Please do not connect the power cord or turn on the main unit until
you have fully read the installation guides and followed the instructions!!!
TECHNICAL ENHANCEMENTS
Applicable technical enhancements in PB-2200 Pro series include
serial COM port power supply settings, RTC battery replacement, VGA port
power supply setting, DRAM upgrades and adding a half-length PCI adapter
card. All these technical enhancement operations require purchase of
applicable Technical Manual from Posiflex or consultation from Posiflex
authorized dealers and should be handled only by a qualified technician.
NON-USER-INSTALLABLE OPTIONS
When the PB system is ordered with options like expanded system
memory, 2nd HDD or CF memory card reader slot, the option(s) is (are)
already installed in the system delivered. Therefore, no more installation is
required.
HALF LENGTH PCI EXTENSION CARD
The whole installation operation of a half-length PCI extension card
involves cautiously accessing the interior of the system, replacing the slot
window metal plate, applying the card and installing its driver. Therefore, only
a computer expert can perform this operation on his own risk.
MAIN CONNECTION AREA
The PB series is constructed for very easy maintenance. Press inward
both plastic buttons at lower rear
corners on both sides of the
Push this button
and also the one
on the other side
to open Cable
Cover
system unit (circled in right
picture) to release the lower part
of back cable cover. Please note
that there are 2 plastic hooks on
top cover holding the back cable
cover as marked on upper part of
the picture. Carefully release the
back cable cover from the hooks
to show the main connection area.
Note: Never press the 2 springs on the metal walls as cross marked in the
picture. Carelessly pressing on these 2 springs could cause damages. The user
shall be responsible for such kind of damage. Even the maintenance
technician must always pay attention to always disconnecting all power and
cable connections before pressing the 2 springs and not to cause any damage
Part 6
Download from Www.Somanuals.com. All Manuals Search And Download.
either in the top cover opening operation after pressing the 2 springs or by
leaving or spilling any improper materials inside after the opening operation.
POWER ADAPTOR
The power connector resides in the lower left
corner of main connector area. Please make sure that
the cable from the power adaptor is inserted into the
power connector of PB system in the correct orientation
as illustrated in right drawing. The manufacturer is not
responsible for any damage caused by improper
orientation of this connection. Please check that for
straight type power plug the arrow mark on the plug is
at top side of the plug. For right angled power plug, if
the arrow mark is on its end, it should be pointing up. If
the arrow mark is on one side of the right angled power
plug, it should be on the right as in the drawing. Please
also check that the city power supply specification from the wall socket is
within the operation range of the power adaptor.
UPS BATTERY (OPTION)
When the PB system is installed with the UPS battery, the UPS
battery is in the carton at delivery. Please take it out and place it in the battery
compartment at center upper part of the connection area indicated as upper
rectangle in picture at right. Connect the cable
UPS Battery Compartment
to its connector in the main connection area
beside the power connector only when the
system is about to power up for operation.
Always disconnect the UPS battery when the
system is to be left powered off for more than
few days. Please pay particular attention to the
environment requirement for UPS battery in
next chapter “USING THE PB SYSTEM”.
UPS Battery Connector
SIDE MOUNT UPGRADE KIT (OPTION TO TM/LM-7112)
When a side-mount upgrade kit option SD-300 or BC-300 is ordered
with the optional TM/LM-7112 LCD panel, this option is already installed in
the delivery. If they were to be later installed or if the side mount upgrade kit is
KP-210, they have to be mounted to the right edge of LCD display at the 2
screws. Then connect the USB cable (If KP-210 is without the smart card
reader, there could be no USB cable.) to the USB port of the PB system and
connect the PS/2 cable of KP-210 to PS/2 KB port of the PB system.
Part 7
Download from Www.Somanuals.com. All Manuals Search And Download.
WIRELESS LAN (OPTION)
When the wireless LAN option is ordered with the PB system, this
option is already installed in the delivery inside the back cable cover with its
cable connected to one of the USB port. This cable must be disconnected
first if installed whenever the back cable cover is opened for any operation.
CUSTOMER DISPLAY (OPTION)
When the PB series is ordered with the customer display option, the
customer display together with the pole for installing them to corner of back
cable cover will be delivered in separate package from the system unit. Please
follow the Installation Guide in package of the option. The customer
display will occupy one COM port or one USB port. However, before
installing an integrated customer display option on a PB system, please have a
qualified electronics technician to set up power supply to the customer display
in the COM port used if the pole display is of RS232 interface and to
neutralize the power supply once the customer display is to be removed from
that port.
AUDIO PORT
The audio output port must be connected to either the earphone or a
pair of speakers with booster or amplifier if used. When the audio amplifier
option is installed, there will be an internal speaker inside the main unit with
amplifier constructed on the internal PCI riser card.
PROGRAMMABLE KEYBOARD (OPTION)
All types of Posiflex programmable keyboards can be applied in PB
system. Most recommended models are: KB-6000, KB-6200 series and KB-
6600. Just connect it to the PS/2 KB port in the main connection area. The
application of the keyboard requires no software driver and is free from any
software compatibility issue. The system integrator can program the content of
the keyboard for the application software following the technical guidance of
Posiflex keyboard programming utilities.
BARCODE SCANNER (OPTION)
Modern barcode scanners applied in POS business are usually of KB
interface type. Most of them provide both a male and a female PS/2 KB
connector. Therefore it can be connected either to the bottom of the Posiflex
programmable keyboard with the cable fit into the strain relief groove or in
between the PS/2 KB port of the system unit and the Posiflex programmable
keyboard. The only consideration is that in programming stage of the
programmable keyboard, nothing (including the barcode scanner) should come
in between the system and the programmable keyboard. However, this should
be no problem in application phase.
When a KB interface barcode scanner is installed in PB series, a
Part 8
Download from Www.Somanuals.com. All Manuals Search And Download.
connection of a normal PS/2 keyboard or the Posiflex programmable keyboard
could become obligatory by some OS. Therefore, if there will be no keyboard
installed for such OS, it is advisory to use an USB interface type barcode
scanner instead of the PS/2 KB interface type.
PRINTER (OPTION)
There are many models of Posiflex POS printers that can be applied
in PB system. These printers cover several interface technologies. Please
connect the printer to a COM port, the LPT port or an USB port in the main
connection area depending on the printer model and then connect its power
adaptor. It is also possible to control a Posiflex wireless POS printer by
connecting a separately purchased wireless Dongle to one of the COM ports in
PB system.
CASH DRAWER (OPTION)
The RJ11 connector in main connection area of a PB system can be
used for controlling most of the common cash drawers available on the market.
However, it is recommended that the Posiflex CR-2000 (flip-top type) or
(sliding drawer type) CR-3100 / CR-3200 / CR-4000 / CR-4100 / CR-4210 /
CR-6210 be used for best compliance.
The PB system will directly control the cash drawer using the cash
drawer port (CR) both to operate the opening mechanism and to monitor the
drawer open status. Both functions may be accomplished under software
control of the COM1 serial port.
Use the cable supplied with the Posiflex cash drawer (Part No.
21863018010) for connection to the CR port in PB system. This cable has a 6-
pole RJ11 plug at one end and an 8-pole RJ45 plug at the other. The 8-pole
plug should be inserted into the connector marked: “signal cable from POS
Printer” at the rear of the cash drawer. The 6-pole plug should be inserted in
the connector marked “CR” found in the main connection area in the system.
The user may also use the optional 2-in-1 cash drawer control cable
21863023800 to control 2 cash drawers in 1 port. It has a 6-pole plug at one
end and two 8-pole plugs at the other. The 6-pole plug should be inserted in
the connector marked “CR” found in the main connection area in the system.
Each 8-pole plug should be inserted into the connector marked “signal cable
from POS Printer” at the rear of one of the cash drawers. The cable lengths for
the two 8-pole plugs are different. Use the shorter one for the original cash
drawer “CR1” and use the longer one for the extended cash drawer “CR2” that
will be distinguished by the software command.
OPERATING SYSTEM RECOVERY
The operating system exists in the HDD in top of the system unit.
Once the software system on HDD collapses, it is possible to restore the
operating system onto a physically intact HDD with use of the Recovery CD
Part 9
Download from Www.Somanuals.com. All Manuals Search And Download.
that comes with the preloaded operating system. Please follow the instruction
from your system integrator for system / software restoration. Follow the
instructions below for operating system recovery only if your system integrator
does not advise otherwise.
For the PB system preloaded with Windows system on HDD, Posiflex
provides recovery CD delivered with the terminal for the preloaded operating
system. The System Integrator shall take care of software restoration after OS
recovered. Use a Posiflex supplied USB interface external CDROM drive for
such action. Other brand CDROM drive may require its specific driver
different from what supported in the recovery CD.
Please use the recovery CD in rescue operation only. Using it
otherwise may wipe out whatever stored in the HDD! All upgrade devices
drivers needed for manual installation in usual way are available in the
subfolder “\drivers” in OS recovered HDD and the latest versions of these
Now please follow instructions from your system integrator for
software recovery after OS recovery and driver installation.
OPERATING SYSTEM INSTALLATION
This product is a highly professionalized equipment. The installation
of an OS into a machine without any preloaded OS could constitute major
difficulty for average user who either has barely limited technical knowledge
of this professionalized equipment or is insufficiently equipped with necessary
facilities to accomplish such a task. Therefore, installation of an OS into a
system without preloaded OS is highly discouraged. Posiflex shall not be
responsible for any technical support to questions arisen due to non-preloaded
OS.
Part 10
Download from Www.Somanuals.com. All Manuals Search And Download.
USING THE PB SYSTEM
BEFORE POWER ON – A Check List
It is very important that you check the following operational points:
Ventilation
This terminal must NOT be operated in an environment with
restricted ventilation. There must be at least 25 mm air clearance around any
top or side ventilation holes with a free flow of air around the unit at ALL
times for the installation.
Operating Environment
The equipment must not site in direct sunshine, near a heater or in a
damp area and must be free from contaminants like dust, smoke or fume.
The equipment must not be operated or stored in extremes of both
temperature and humidity/moisture.
(Operating range 0°C to + 35°C and up to 80% relative humidity –
non condensing max. wet bulb 26°C)
Power Supply
The operating voltage of the power supply should be checked to
confirm that it is set within the range of the local power supply. The power
cable, the power outlet and any power fusing arrangements must conform to
local safety regulations.
UPS Battery (option)
General care:
The UPS battery is consumable beyond product warranty. Please
definitely observe the alerts in beginning of this manual. If the equipment is to
be powered off for more than few days, please always disconnect the battery
from the system. Reconnect it and turn on the system to recharge the battery
for 1 ~ 2 hours every 3 months for temperature lower than 30°C. Recharge for
1 ~ 2 hours every month for temperature over 30°C. Temperature above 40°C
must be strictly avoided as it could cause termination of battery life and
unexpected result even if the battery is not in work. The UPS battery can
support basically the data preservation and smooth running of the system
during intermittent or few minutes (3 ~ 20 min. depending on loading and
battery condition) power failure.
Battery replacement:
In the preloaded OS for a PB-2200 Pro series, there is a built in
utility Posiflex Power Switch Manager that will
indicate the UPS battery status of the battery. When
an installed UPS battery is found to be disabled or
when pop up warning message like this picture
Part 11
Download from Www.Somanuals.com. All Manuals Search And Download.
appears, please replace the used up UPS battery at power off as soon as
possible.
Emergency treatment:
The battery is constructed maintenance free and leakproof. Its storage
space in PB system also provides very good protection as long as the ambient
temperature remains below 30°C and the ventilation of the PB system remains
free. However, should any accident happen and the sulfuric acid from the
battery spills on skin or clothing, wash immediately with water. If the acid
comes in contact with eyes, rinse eyes with large amount of clean water and
see a doctor immediately. A larger external battery may be connected to give
an extended operation. Please check your dealer about this capability when
required.
WARNING:
If there are any signs of over charging or leakage of electrolyte
please contact your dealer immediately
VGA Display Port
The VGA port in the PB terminal can support a 12 volt DC power to
the external monitor through the VGA signal cable. This may cause permanent
damage to any other monitor not designed to use this facility. Please use only a
Posiflex monitor designed for the PB system when the 12 volt DC power is
supported. Consult your dealer if you have any doubt.
(Note: 12 volt DC power is available on pin 9 of the VGA connector and
is supported by the UPS function if the UPS function module option with UPS
battery is installed.)
The video memory of this port shares from the system memory. The
video memory size can be set in the BIOS CMOS setting to match the user’s
application.
Serial Port – COM1
For the PB system with the UPS function, a COM1 terminator will
also be supplied. Please always occupy COM1 serial port by a suitable serial
device or this terminator. If this port is left vacant or connected with something
like a mouse, the power switch management and the cash drawer control may
fail to work correctly. An RS232 MODEM is not applicable to this port. It is
recommended to use COM2.
Part 12
Download from Www.Somanuals.com. All Manuals Search And Download.
POWER ON/OFF CONTROL
The PB terminal implements electronic power control, such that the
main power to the system may be controlled by many methods as below:
1. Hardware power switch
2. Software OFF command
3. Automatic power ON control
4. Emergency power OFF
Switching from OFF to ON requires a normal supply of the AC power.
Hardware Power Switch
This button is located at bottom front
corner of right side as in right picture and can be
used to turn the system on and off alternatively. This
hardware switch can also be programmed to be an
ON only switch through software command so that
when this switch is accidentally pressed during system turned on, the system
just remains on and unaffected.
Software Off Command
The system may also be shut down under software control. Please just
follow the arrangement by your system integrator for this capability.
Automatic Power On Control
The system may also turn on according to some preset conditions
such as Modem Ring Up and Alarm Clock Wake Up or LAN Wake Up.
To utilize Modem Ring Up or Alarm Clock Wake Up function, the
user should enter the CMOS setup by pressing “Del” key at system boot up,
choose for “PM Wake Up Events” in “Power Management Setup” and make
the “Ring Power Up Control” enabled for Modem Ring Up or select the
“Power Up by Alarm” for Alarm Clock Wake Up. Save the configuration and
exit the CMOS setup program. The Preset Power On Control will then be
ready after a normal power off. For LAN wakeup, an operating caller system
connected through LAN to the system is required. It also requires a qualified
networking technician to check the LAN chip ID of the PB system for the
caller system to wake it up.
When the PB system is turned off after a successful boot up, the
preset automatic power on functions will keep monitoring for the preset
conditions and turn on the system when the preset conditions are met.
Please note that if the PB system is improperly turned off before a
complete boot up procedure, the above preset power on control functions will
be disabled until next turning off after a complete boot up.
Part 13
Download from Www.Somanuals.com. All Manuals Search And Download.
Emergency Power Off
In case of serious system halt due to any reason, the system could fail
to be powered off through normal means. Press and hold the Power ON/OFF
Switch for Emergency Power Off. Release the switch after the system powered
off. It will take about 10 seconds. If there appears to give a special coded beep
tone in the pattern “short, long, short, long, short” prior to the system power
off in this process, please remove the AC power and wait for few minutes to
allow the hardware registers to reset (If there is no such beep, AC removal is
not required). Then you may restart the system and take remedial action
against the precious failure.
UPS Function
When the UPS battery is installed, this function can be automatically
enabled if the machine is operating on the preloaded OS from the manufacturer.
When the external power is interrupted during system operation with the UPS
function enabled, the system will give periodical beep to indicate the status of
system working on battery power. The beep will go rather fast when the UPS
battery approaches a fully discharged condition to remind the operator that
power will soon finish. In few seconds, the whole system will soon be
automatically turned off. In case the AC power resumes during the usage of
the battery power, the battery operation will keep on for few seconds before
the AC supply is confirmed stable.
CUSTOMER DISPLAY
The optional customer display PD-2601 or PD-7321 mounted on a
pole at rear corner of PB system can be turned horizontally for best viewing
effect in application.
FAN CONTROL
In the preloaded OS for this PB system, there is an embedded function
that can keep on monitoring the interior temperature and the fan revolution rate
and regulating each required fan power to gain
maximum ventilation effect with lowest possible
noise. This function is disabled by default at
delivery. The user can decide to engage this
function by clicking “Start” --> “Programs” -->
“Posiflex Tools” --> “Posiflex Fan Control” to
pop up a window like the right picture. Click
“Enable” then “Apply” to engage this function
in background. This function will remain
operating even after system restart. To disable this function, you have to pop
up this window again and click “Disable” then “Apply” and restart the system.
If system hang due to CPU overheat occurs, please review the ventilation
Part 14
Download from Www.Somanuals.com. All Manuals Search And Download.
condition and environment temperature, check if the fan is stuck by
contaminants such as dry grease or threads and try to correct the situation
when the system is off and cooled down. You may power up the system again
after the system cooled down and trouble cause removed. However, if the
trouble remains, please consult your dealer for possibly fan replacement on
worn out.
USB
There are in total six standard USB female connectors in the rear
room. All support the Universal Serial Bus Specification standard 2.0 and also
1.1. If for any reason (though very unlikely in ordinary practice) these ports
has to be limited as USB 1.1 only, please enter BIOS setup and go to
“Integrated Peripherals” then “SiS OnChip PCI Device” and disable the item
“USB 2.0 Supports”.
One among the six USB ports can be extended to top edge of system
unit for the side-mount upgrade kit by a cable.
VENTILATION MAINTENANCE
To keep this equipment in orderly service, following maintenance
should be performed on a regular basis.
Removing Front Cover
Please first remove any power and signal connection to this
equipment. Please then check at the bottom side of the chassis that there is a
gap between the bottom side of front cover and the chassis at the left corner of
front cover. Pull the front
cover out from this
Front Cover
opening to release the
left side hook of front
cover from the chassis as
indicated by the hollow
arrow in the right picture.
Release Opening
Chassis Bottom View
Please then pull the bottom side of front cover
forward to release the bottom hooks of front cover from
the chassis as indicated by hollow arrow in left picture.
Now pull the left side of
front cover down a little to free it
from the main cover as in the right
picture.
Part 15
Download from Www.Somanuals.com. All Manuals Search And Download.
It may be required to push the power
switch down to completely remove the front cover.
Power Switch
Cleaning for Front Ventilation
Use vacuum cleaner to remove any dust or threads accumulation
away from both the ventilation holes on front cover and ventilation grids on
chassis exposed after removal of the front cover.
Front Ventilation Grids on Chassis
Ventilation Holes on Front Cover
Replacing Front Cover
Follow the opposite procedure as removing the front cover to replace
the front cover in position. Please make sure the all hooks on front cover is
well positioned into chassis. Please remember to check that the power switch is
at “Off” position before power and signal connection.
Accessing Side Ventilation Grids
The operation to further clean the side ventilation grids requires much
more highly technical maneuver. Therefore careful attentions must be taken
throughout the further cleaning operations below. When the main unit is
opened, there must be no liquid spill,
no electro-conductive material, no
Push the
electric charged device come into the
spring
area of the main unit. Please also note
buttons on
that not to touch any component or
both sides
cable inside.
and raise the
Please first disconnect every
rear part of
cable from the main unit and prepare
Top Cover
enough space in front of the PB
system and lay a piece of clean soft
clothe of appropriate size there to
prevent damage. With the back cable cover opened, push in the circled spring
button in the above picture on both sides of chassis and raise the rear edge of
the top cover. Apply some mild maneuver if there is already a pole display
mounted.
Part 16
Download from Www.Somanuals.com. All Manuals Search And Download.
Cleaning for Side Ventilation
Use vacuum cleaner to remove any dust or threads accumulation
away from outsides of both ventilation grids on chassis exposed after removal
of the front cover as in pictures below and close back the top cover when done.
Side
Ventilation
Grids on
Chassis
Part 17
Download from Www.Somanuals.com. All Manuals Search And Download.
Part 18
Download from Www.Somanuals.com. All Manuals Search And Download.
Part 19
Download from Www.Somanuals.com. All Manuals Search And Download.
T31454
警告使用者
這是甲類的資訊產品,在居住的環
境中使用時,可能會造成射頻干
擾,在這種情況下,使用者會被要
求採取某些適當的對策。
Part 20
Download from Www.Somanuals.com. All Manuals Search And Download.
|