Power Supply  
Product Overview  
• Designed specifically for Agilent Technologies  
microwave system amplifiers  
• Bias cable permits remote placement  
• Compact size for easy system integration  
The Agilent 87421A and 87422A power supplies  
are universal input, dc switching power supplies  
designed to provide the bias voltages needed to  
operate Agilent microwave system amplifiers.  
The 87422A is a 90 watt, 15V dc power supply  
designed to power the Agilent 83020A microwave  
system power amplifier. One additional 12V dc  
output is provided to power a preamp such as  
the 83006A or 83017A.  
These compact power supplies are ideal for inte-  
gration into a system or for use on a benchtop.  
The 2 meter dc bias cable permits the amplifier  
to be remotely located, allowing it to be placed  
out of the way or where space is not critical.  
Included with the power supply are the necessary  
2 meter cables to connect to the amplifier.  
The 87421A may also be used to provide bias volt-  
ages for the Agilent 83440C high speed lightwave  
converter. Using the 83440-60009 lightwave con-  
verter power supply adapter, the 87421A becomes  
a compact, convenient power supply for use with  
the lightwave converter.  
The 87421A is a 25 watt, 12V dc power supply  
designed to power the Agilent 83006A, 83017A,  
83018A, and 87415A microwave system amplifiers.  
A 2 meter cable is included for direct connection  
to the amplifier.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
cable. For help with special applications requiring  
longer cables contact your Agilent call center listed  
on the back page.  
Other product and operating information  
Operation of the power supplies involves connect-  
ing the power supplies output to the amplifier dc  
input with the cable provided. The power supplies  
include a power cord with protective ground for  
connection to 90–240 VAC.  
The power supplies have a fuse located next to  
the IEC appliance inlet. If it is necessary to replace  
the fuse, disconnect the power supply from both  
AC power and the amplifier. Using a slotted screw-  
driver, open the fuse cover and replace the fuse.  
Mounting holes are provided as shown in the out-  
line drawings. The power supplies may be mounted  
in any orientation with user supplied hardware.  
The power supplies contain no user serviceable  
parts (with the exception of the fuse). If service is  
required, please contact your Agilent sales office  
or nearest Agilent Service Center.  
To ensure continued compliance to product safety  
and EMC specifications, connect the power supplies  
to an amplifier only with the cable provided. Do  
not attempt to modify or extend the dc output  
The Agilent 87421A power supply provides the dc power needed to bias the 83006A, 83017A, and 83018A. The power  
supply comes with a 2 meter long cable to allow easy connection between the amplifier and the power supply.  
Dimensions in millimeters and (inches).  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Other instruments and accessories  
83006A Microwave System Amplifier,  
0.01 to 26.5 GHz  
83017A Microwave System Amplifier,  
0.5 to 26.5 GHz  
83018A Microwave System Amplifier,  
2 to 26.5 GHz  
83020A Microwave System Power Amplifier,  
2 to 26.5 GHz  
Ordering information  
Agilent 87421A power supply  
Includes power supply, AC power cord, and part  
number 83006-60005, which is a 2 meter cable with a  
3-pin connector on one end and a D-subminiature  
connector on the other end for direct connection to  
the Agilent 83006A, 83017A, 83018A, and 87415A  
microwave system amplifiers.  
87415A Microwave System Amplifier,  
2 to 8 GHz  
83440C High Speed Lightwave Converter,  
dc to 20 GHz, 1000 to 1600 mm  
83440-60009 Lightwave Converter Power  
Supply Adapter  
Agilent 87422A power supply  
Includes power supply and part number 83020-60001,  
which is a 2 meter cable with 15-pin connectors for  
direct connection to the Agilent 83020A amplifier.  
One additional dc output is provided to supply power  
to a preamplifier such as the 83006A or 83017A.  
The Agilent 87422A power supply provides the dc power needed to bias the 83020A. DC cables shown above shipped  
with power supply. Dimensions in millimeters and (inches).  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety and Regulatory Information  
Manufacturer’s Declaration  
This is to certify that this product meets the requirements specified in IEC 1010 and  
IEC Publication 348, Safety Requirements for Electronic Measuring Apparatus. It has  
been supplied in a safe condition for indoor use only and may occasionally be subjected  
to temperatures between +5 and –10 Celsius without degradation of its safety. The  
present data sheet contains some information and warnings which have to be followed  
by the user to ensure safe operation and to retain the product in safe condition. The  
main plug shall be inserted in a socket outlet provided with a protective earth contact.  
The protective action must not be negated by the use of an extension cord without  
a protective conductor. Warning: Any interruption of the protective conductor inside  
or outside the product or disconnection of the protective earth terminal is likely to  
make the equipment dangerous. Intentional interruption is prohibited. This product  
has been designed to be safe under the following environmental conditions: indoor use;  
altitude up to 2,000 meters; temperature range expanded to include 0 to +55 Celsius;  
maximum relative humidity 80% up to 31 degrees Celsius decreasing linearly to 50%  
relative humidity at 40 degrees Celsius; mains supply voltage fluctuations not to exceed  
10% of nominal voltage; transient over voltage category II for the main ac supply  
voltage; pollution degree two. If the equipment is used in a manner not specified by  
Agilent Technologies, the protection provided by the equipment may be impaired.  
Model 87422A  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
DECLARATION OF CONFORMITY  
according to ISO/IEC Guide 22 and CEN/CENELEC EN 45014  
Manufacturer’s Name:  
Agilent Technologies, Inc.  
Manufacturer’s Address:  
1400 Fountaingrove Parkway  
Santa Rosa, CA 95403-1799  
USA  
Declares that the products  
Product Name:  
Microwave System Amplifiers  
Model Numbers:  
83006A, 83017A, 83018A, 83020A, 83050A,  
83051A, 87421A, and 87422A  
Product Options:  
This declaration covers all options of the  
above products.  
Conform to the following product specifications:  
EMC: IEC 61326:1997+A1:1998+A2:2000/ EN 61326:1997+A1:1998+A2:2001  
Standard  
Limit  
CISPR 11:1997 / EN 55011:1998/A-1999  
IEC 61000-4-2:1995+A1998 / EN 61000-4-2:1995  
IEC 61000-4-3:1995 / EN 61000-4-3:1995  
IEC 61000-4-4:1995 / EN 61000-4-4:1995  
IEC 61000-4-5:1995 / EN 61000-4-5:1996  
IEC 61000-4-6:1996 / EN 61000-4-6:1998  
IEC 61000-4-11:1994 / EN 61000-4-11:1998  
Group 1, Class A  
4 kV CD, 8 kV AD  
3 V/m, 80 - 1000 MHz  
0.5 kV sig., 1 kV power  
0.5 kV L-L, 1 kV L-G  
3 V, 0.15 – 80 MHz  
1 cycle, 100%  
Supplementary Information:  
The products herewith comply with the requirements of the Low Voltage Directive 73/23/EEC  
and the EMC Directive 89/336/EEC and carry the CE-marking accordingly.  
Santa Rosa, CA, USA  
25 November, 2002  
Greg Pfeiffer/Quality Engineering Manager  
For further information, please contact your local Agilent Technologies sales office, agent or distributor.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Agilent Technologies’ Test and Measurement Support, Services, and Assistance  
Agilent Technologies aims to maximize the value you receive, while minimizing your  
risk and problems. We strive to ensure that you get the test and measurement  
capabilities you paid for and obtain the support you need. Our extensive support  
resources and services can help you choose the right Agilent products for your  
applications and apply them successfully. Every instrument and system we sell has  
a global warranty. Support is available for at least five years beyond the production  
life of the product. Two concepts underlie Agilent’s overall support policy:  
“Our Promise” and “Your Advantage.”  
Our Promise  
Our Promise means your Agilent test and measurement equipment will meet its  
advertised performance and functionality. When you are choosing new equip-  
ment, we will help you with product information, including realistic performance  
specifications and practical recommendations from experienced test engineers.  
When you use Agilent equipment, we can verify that it works properly, help with  
product operation, and provide basic measurement assistance for the use of speci-  
fied capabilities, at no extra cost upon request. Many self-help tools are available.  
Your Advantage  
Your Advantage means that Agilent offers a wide range of additional expert test and  
measurement services, which you can purchase according to your unique technical  
and business needs. Solve problems efficiently and gain a competitive edge by con-  
tracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and  
onsite education and training, as well as design, system integration, project man-  
agement, and other professional engineering services. Experienced Agilent engi-  
neers and technicians worldwide can help you maximize your productivity, optimize  
the return on investment of your Agilent instruments and systems, and obtain  
dependable measurement accuracy for the life of those products.  
Agilent T&M Software and Connectivity  
Agilent’s Test and Measurement software and connectivity products, solutions and  
developer network allows you to take time out of connecting your instruments to  
your computer with tools based on PC standards, so you can focus on your tasks,  
not on your connections. Visit www.agilent.com/find/connectivity  
for more information.  
By internet, phone, or fax, get assistance with all your test & measurement needs  
Phone or Fax  
Korea:  
United States:  
(tel) 800 452 4844  
Canada:  
(tel) 877 894 4414  
(fax) 905 282 6495  
China:  
(tel) (82 2) 2004 5004  
(fax) (82 2) 2004 5115  
Latin America:  
(tel) (305) 269 7500  
(fax) (305) 269 7599  
Taiwan:  
(tel) 800 810 0189  
(fax) 800 820 2816  
Europe:  
(tel) (31 20) 547 2323  
(fax) (31 20) 547 2390  
Japan:  
(tel) 0800 047 866  
(fax) 0800 286 331  
Other Asia Pacific  
Countries:  
(tel) (65) 6375 8100  
(fax) (65) 6836 0252  
Email:  
(tel) (81) 426 56 7832  
(fax) (81) 426 56 7840  
Product specifications and descriptions in this document  
subject to change without notice.  
© Agilent Technologies, Inc. 1997, 2000, 2002  
Printed in USA, November 26, 2002  
5091-4292E  
Get the latest information on the  
products and applications you select.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Acer Personal Computer M5150 User Manual
Acumen Fitness Electronics JogPal Plus User Manual
Addonics Technologies All in One Printer DGC3 User Manual
Agri Fab Spreader 45 0315 User Manual
Agri Fab Spreader 45 03295 User Manual
Aiwa Stereo System Z L31 User Manual
Allied Telesis Switch AT FS705L User Manual
American Sensor Carbon Monoxide Alarm NG401 User Manual
BC Speakers Speaker 12 HPL 76 User Manual
Behringer Music Mixer XENYX QX1222 User Manual