Acnodes Computer Hardware MPC 6171A User Manual

MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
User Manual  
MPC 6171A: 17” Industrial Medical Grade Panel PC with Core 2 Duo 2.20GHz processor  
MPC6171B: 17” Industrial Medical Grade Panel PC with Core 2 Duo 2.20GHz processor (No Touch Screen)  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
FCC CLASS B  
This equipment has been tested and found to comply with the limits for a Class B digital device,  
pursuant to Part 18 of the FCC Rules.  
These limits are designed to provide reasonable protection against harmful interference when the  
equipment is operated in a residential environment. This equipment generates, uses and can radi-  
ate radio frequency energy. If not installed and used in accordance with this user manual, itmay  
cause harmful interference to radio communications.  
Note that even when this equipment is installed and used in accordance with this user manual, there  
is still no guarantee that interference will not occur. If this equipment is believed to be causing  
harmful interference to radio or television reception, this can be determined by turning the equip-  
ment on and off. If interference is occurring, the user is encouraged to try to correct the interference  
by one or more of the following measures:  
Reorient or relocate the receiving antenna  
Increase the separation between the equipment and the receiver  
Connect the equipment to a power outlet on a circuit different from that to which the receiver  
is connected  
Consult the dealer or an experienced radio/TV technician for help  
Warning:  
Any changes or modifications made to the equipment which are not expressly approved by the  
relevant standards authority could void your authority to operate the equipment.  
Caution:  
Danger of explosion if battery is incorrectly replaced, replace only with the same or equivalent type  
recommended by the manufacturer. Dispose of used batteries according the manufacturer's instruc-  
tions.  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
SAFETY INSTRUCTIONS  
Greeting & Setup  
Thank you for purchasing the MPC6171A/ MPC6171B unit. We wish that this unit will be durable  
and reliable in providing your medical application needs. Please follow the instructions below to  
ensure the unit continues to have high performance.  
Unpacking  
After opening the carton, there will be a Monitor display unit with an accessory box. Examine the  
contents to see if there are damages to the unit and if all accessories are present.  
Setting up  
Please read this manual carefully and remember to keep this manual for future reference.  
Safety Instructions & Cleaning  
The unit has undergone various tests in order to comply with safety standards. Inappropriate use of  
the open frame unit may be dangerous. Please remember to follow the instructions below to insure  
your safety during the installation and operating process.  
Transporting & Placement of unit  
1. When moving the unit on a cart; be very cautious. Quick stops, excessive forces and uneven  
surfaces may cause the cart to overturn thus risking the unit to fall to the ground.  
2. If the Monitor display unit does fall to the ground, immediately turn the power off and disconnect  
cords. Then contact a service technician for repairs. Continual use of the unit may result cause a  
fire or electric shock. Also, do not repair the unit on your own.  
3. Having two or more people transporting the display unit is recommended. In addition, when  
installing the unit by suspending it also requires two or more people.  
4. Before suspending the unit, make sure the material used for suspension is sturdy and stable. If  
not properly suspended, the display unit may fall and cause serious injury to people standing nearby  
as well as to the unit itself.  
5. If you wish to mount the display unit, remember to use only the mounting hardware recommended  
by the manufacturer.  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
Electrical and Power Source Related  
1. This Monitor display unit must operate on a power source as shown on the specification label. If  
you are not sure what type of power supply used in the area, consult your dealer or local power  
supplier.  
2. The power cords must not be damaged. Applied pressure, added heat, and tugging may dam-  
age the power cord.  
3. The power cord must be routed properly when setup takes place. We advise that this aspect  
measure is to prevent people from stepping on the cords or while the unit is suspended to prevent  
flying objects from getting tangled with the unit.  
4. Do not overload the AC outlets or extension cords.  
Electrical shocks or fires may occur from overloading.  
5. Do not touch the power source during a thunderstorm.  
6. If your hands are wet, do not touch the plug.  
7. Use your thumb and index finger, grip firmly on the power cord to disconnect from the electrical  
socket. By pulling the power cord, may result in damaging it.  
8. If the unit is not going to be in use for an extended period of time, remember to disconnect the  
unit.  
9. The Monitor display unit uses voltage between 90-264VAC. Connect the unit to a power source  
with the same numerical value as shown. Please use only the power cord provided by the dealer to  
ensure safety and EMC compliance.  
Various Factors of Environment  
1. Do not insert objects into the openings.  
2. Do not have liquids seep into the internal areas of the Monitor display unit.  
3. Having liquids seep in or inserting objects into the unit may result in electric shocks from taking  
and/or short circuiting the internal parts.  
4. Do not place the Monitor display unit in the presence of high moisture areas.  
5. Do not install the Monitor display unit in a wet environment.  
6.  
7.  
Do not place near unit near heat generating sources.  
Do not place the unit in a location where it will come in contact with fumes or steam.  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
8. Remember to keep the Monitor display unit away from the presence of dust.  
9. If water has flow in or seep in, immediately disconnect the open frame unit. Then contact a ser-  
vice technician for repairs.  
Ventilation Spacing  
1. Do not cover or block the openings on the top and back sides of the display unit. Inadequate  
ventilation may cause overheating thus reducing the lifespan of the unit.  
2. Unless proper ventilation is present, do not place unit in an enclosed area; such as a built-in  
shelf. Keep a minimum distance of 10 cm between the display unit and wall.  
Cleaning the unit  
1. Remember to turn off the power source and to unplug the cord from the outlet before cleaning the  
unit.  
2. Carefully dismount the unit or bring the unit down from suspension to clean.  
3. Please use a dry soft cloth to clean the unit.  
4. Take a dry cloth and wipe the unit dry. Remember to avoid having liquids seep into the internal  
components and areas of the Monitor display unit.  
Servicing, Repairing, Maintenance & Safety Checks  
1. If the unit is not functioning properly, observe the performance level of the display closely to deter-  
mine what type of servicing is needed.  
2. Do not attempt to repair the Monitor display unit on your own. Disassembling the cover exposes  
users' to high voltages and other dangerous conditions. Notify and request a qualified service  
technician for servicing the unit.  
3. If any of the following situations occur turn the power source off and unplug the unit. Then contact  
a qualified service technician  
(a) A liquid was spilled on the unit or objects have fallen into the unit.  
(b) The unit is soaked with liquids.  
(c) The unit is dropped or damaged.  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
(d) If smoke or strange odor is flowing out of the operating unit.  
(e) If the power cord or plug is damaged.  
(f) When the functions of the unit are dysfunctional.  
4. When replacement parts are needed for the Monitor display unit, make sure service technicians  
use replacement parts specified by the manufacturer, or those with the same characteristics and  
performance as the original parts. If unauthorized parts are used it may result in starting a fire,  
electrical shock and/or other dangers.  
Caution:  
DO NOT LEAVE THIS EQUIPMENT IN AN UNCONTROLLED ENVIRONMENT WHERE THE  
STORAGE TEMPERATURE IS BELOW  
-20° C (-4° F) OR ABOVE 60° C (140° F). THIS MAY DAMAGE THE EQUIPMENT.  
This equipment shall not be used in life support systems.  
The user is not to touch SIP/SOPs and the patient at the same time.  
The sound pressure level at the operator's position according to IEC 704-1:1982 is no more than  
70dB (A).  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
Table of Contents  
CHAPTER 1 INTRODUCTION  
1.1 PRODUCT DESCRIPTION.............................................................................................. 1  
1.2 PACKAGE LIST ............................................................................................................... 2  
1.3 FEATURES ...................................................................................................................... 3  
1.4 SPECIFICATIONS ........................................................................................................... 3  
1.5 CLEANING/ DISINFECTING ........................................................................................... 6  
CHAPTER 2 GETTING STARTED  
2.1 SYSTEM SET UP ............................................................................................................ 9  
2.2 DIMENSION .................................................................................................................... 10  
2.3 SYSTEM VIEW ............................................................................................................... 11  
2.4 DISCONNECT DEVICE ................................................................................................. 17  
CHAPTER 3 BIOS SETUP  
APPENDIX  
A. JUMPER SETTINGSAND CONNECTORS.................................................................... 36  
B. VESA MOUNTING ........... .................................................................................................45  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
CHAPTER 1 INTRODUCTION  
1.1 PRODUCT DESCRIPTION  
The MPC 6171A/ MPC 6171B Medical Panel PC are based on Intel Core 2Duo processor which  
deliver a performance improvement of more than 100 percent compared to systems running tradi-  
tional single-core processors. With two cores, or computing engines, MPC 6171A/ MPC 6171B can  
simultaneously execute two computing tasks. It accommodates one 2.5" SATA hard disk drive and  
up to 4GB DDR2 SODIMM.  
The high brightness LCD, Low Noise solution, integrated multimedia functions and  
extensive expansion options make them the perfect platform upon which to build comprehensive  
lifestyle computing applications.  
The MPC 6171A/ MPC 6171B includes all the features of a powerful computer into a slim  
and attractive chassis. The MPC 6171A/ MPC 6171B has a 17" high brightness TFT display  
with 1280 x 1024 resolutions.  
The MPC 6171A/ MPC 6171B are compact, Giga LAN and selectable WLAN network compatible  
PC with full safety and medical approval and features to control a dedicated system with a wide  
variety of applications. Combining the MPC 6171A/ MPC 6171B into your system can achieve both  
cost-saving and efficient improvements.  
Common applications include Surgical, Radiology, PACS (Picture Archiving  
Communication  
Systems), LIS (Lab Information Systems) and Electronic Medical Record. The MPC6171A/  
MPC6171B are definitely your perfect choices.  
1.2 PACKAGE LIST  
Before you begin installing your Medical Station, please make sure that the following items have  
been shipped:  
o The MPC 6171A/ MPC 6171B Medical Panel PC  
o One CD containing user manual, QIG, chipset drivers  
o Power Adapter x 1 (Mf:Sinpro, type/model: MPU100-105)  
o Power cord - Hospital grade used(US type), or other type in UK, EU…etc.  
o Touch pen x 1 (By configuration)  
o Screw x 8 (VESA 75/100 use)  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
1.3 FEATURES  
Intel Core 2 Duo Mobile CPU / Celeron M 550 Solution  
17" 380 nits high brightness  
Highest performance and low power system solution  
Plastic construction with medical outlook color  
Resistive touch screen (optional)  
802.11 b/g wireless LAN Module (optional)  
Bluetooth v2.1 + EDR module (optional)  
Integrated Compact Flash card reader (By configuration, optional)  
Integrated webcam solution (By configuration, optional)  
VESA 75/100 compliance Desktop Stand (optional)  
VESA 75/100 compliance Wall Mount (optional)  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
1.4 SPECIFICATION  
HARDWARE SPECIFICATIONS  
Display 17" 380 nits SXGA color TFT LCD  
CPU Support  
MPC6171: Intel® Core 2 Duo T7500 2.2GHz  
Intel® Celeron M550 2.0GHz  
Disk Drive Space: 2.5" Hard Disk Drive (SATA-150)  
Expansion: One Mini PCI slot; One PCI expansion, One CF card slot expansion or one Smart card  
slot expansion slot (By configuration, optional)  
Button: Brightness: "+" / "-"; Sound: "+" / "-"; Power SW  
I/O:  
Standard Version-  
2 RS-232 ports + 1 RS-232/422/485 port  
4 USB 2.0 ports  
1 DC-in w/ lock function  
1 PS/2 keyboard and 1 PS/2 mouse  
2 Gigabit LAN RJ-45 Connectors  
Sound:  
1 x Line-in  
1 x line-out  
1 x Mic-in  
2 x 2W Speakers on back side  
1 x PCI slot  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
LCD SPECIFICATIONS  
Model Name: G170EG01 (V0)  
Display Type: 17" color TFT LCD  
Max. Resolution: 1280 x 1024  
Contrast Ratio: 1000 : 1 (Typ)  
Pixel Pitch (mm): 0.264 (per one triad) x 0.264  
Luminance (cd/m2): 380 (TYP)  
Viewing Angle: 170°(H)/ 160°(V)  
Operating Temperature: 0°C~ 40°C (32°F~104°F)  
Brightness Control  
Yes  
POWER ADAPTER SPECIFICATIONS  
PowerClose-frame  
MFR: Sinpro  
Type: MPU100-105  
Input Voltage: 100 ~ 240 VAC, 1.25 max. @ 47 ~ 63 Hz  
Output Voltage: 12V @ 8.33 A  
MTBF: 100,000 hrs operation at 25°C  
MECHANICAL SPECIFICATION  
Architecture Close-frame  
Front Bezel Plastic bezel with resistive touch screen  
Color Medical-white  
Mounting / Holder VESA 75/100mm  
Construction 3mm ABS + PC TYPE Plastic housing  
Dimension (WxHxD): 16.5" x 14.2" x 3.2" (420mmx 360mm x 83mm)  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
Net Weight: 15.62 lb (7.0 kg)  
Packing Filler: PE  
ENVIRONMENTAL SPECIFICATIONS  
Operating Temperature: 10°C to 40°C (50°F ~104°F)  
Storage Temperature: -20°C to 60°C (-4°F ~140°F)  
Storage Humidity: 5% to 95%@ 40°C, non-condensing  
Vibration:  
Shock :  
0.5G / 5 ~ 500Hz (Random) / operation  
Operating: 15g/0.53 oz, 11 ms, half sine wave  
Non-operating: 50g/1.76 oz, 11 ms, half sine wave  
Drop: 3 feet (1 Corner, 3 Edge, 6 Surface)  
EMI / Safety: cUL 60601-1, FCC/VCCI class B, EN 60601-1(MDD)/EN 60601-1-2(EMC)  
Noise: MPC6171: Under 30 db  
Altitudes: Operational: 6,000 feet  
Shipping: 40,000 feet  
Input Power Rating: For Adaptor: AC100~240 V, 47 ~ 63 Hz, 1.25A max.  
For Unit: 8.33A (WMP-171); 7.0A (WMP-172)  
Power Consumption: MPC6171:79.50W  
TOUCH SCREEN (OPTIONAL)  
Type: 5-wire, Analog Resistive  
Interface:  
USB interface  
Resolution: 2048 x 2048  
Light Transmission: 80% ± 3%  
Life Time: 35 million activations  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
1.5 CLEANING/ DISINFECTING  
Steps:  
1. Wipe the MPC6171A/ MPC6171B with a dry clean cloth.  
2. Prepare agent per manufacturer's instructions or hospital protocol.  
Cautions:  
Do not immerse or rinse the MPC6171A/ MPC6171B and its peripherals. If you accidentally  
spill liquid on the device, disconnect the unit from the power source. Contact your Biomed regard-  
ing the continued safety of the unit before placing it back in operation.  
Do not spray cleaning agent on the chassis.  
Do not use disinfectants that contain phenol.  
Do not autoclave or clean the MPC6171A/ MPC6171B or its peripherals with strong aro-  
matic, chlorinated, ketone, ether, or Esther solvents, sharp tools or abrasives. Never immerse  
electrical connectors in water or other liquids.  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
CHAPTER 2 GETTING STARTED  
2.1 SYSTEM SET UP  
System Set Up  
The following is a summary of the steps in setting up the system for use.  
(1). You can fix the system to a mounting fixture using the screw holes on the sides of the system.  
(2). Make any required external connections such as the display, keyboard, and LAN.  
(3). Plug the appropriate end of the power cord into the power connector on the rear of the system and  
the plug to an electrical outlet.  
(4). Press the power switch on the front panel of the system once to turn on the system power.  
(5). If necessary, run the BIOS SETUP programs to configure the system.  
Caution:  
In order to boot up system from USB-CD/DVD drive, please connect USB-CD/DVD drive, turn on  
computer power, keep on pressing "F11" key, go into BIOS quick boot menu, select "USB-CD ROM",  
WAIT FOR 20  
SECONDS, then press enter, system OS will boot up from USB-CD/DVD drive directly.  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
2.2 DIMENSION  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
2.3 SYSTEM VIEW  
From left to right:  
1. Brightness down  
2. Brightness up  
3. Power  
4. Volume down  
5. Volume up  
MPC6171A /MPC6172 models  
do not have webcam hold.  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
2.4 DISCONNECT DEVICE  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
CHAPTER 3 BIOS SETUP  
3.1 BIOS Introduction  
The Award BIOS (Basic Input/Output System) installed in your computer system's  
ROM supports Intel processors. The BIOS provides critical low-level support for a  
standard device such as disk drives, serial ports and parallel ports. It also adds virus  
and password protection as well as special support for detailed fine-tuning of the  
chipset controlling the entire system.  
MPC6171A/ MPC 6171B  
The Award BIOS provides a Setup utility program for specifying the system configu-  
rations and settings. The BIOS ROM of the system stores the Setup utility. When you  
turn on the computer, the Award BIOS is immediately activated. Pressing the <Del> key  
immediately allows you to enter the Setup utility. If you are a little bit late pressing the  
<Del> key, POST (Power On Self Test) will continue with its test routines, thus pre-  
venting you from invoking the Setup. If you still wish to enter Setup, restart the system  
by pressing the "Reset" button or simultaneously pressing the <Ctrl>, <Alt> and <De-  
lete> keys. You can also restart by turning the system Off and back On again. The  
following message will appear on the screen:  
Press <DEL> to Enter Setup  
In general, you press the arrow keys to highlight items, <Enter> to select, the <PgUp>  
and <PgDn> keys to change entries, <F1> for help and <Esc> to quit.  
When you enter the Setup utility, the Main Menu screen will appear on the screen. The  
Main Menu allows you to select from various setup functions and exit choices.  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
The section below the setup items of the Main Menu displays the  
control keys for this menu. At the bottom of the Main Menu just below the control keys  
section, there is another section, which displays information on the currently highlighted  
item in the list.  
Note:If the system cannot boot after making and saving system changes with Setup,  
the Award BIOS supports an override to the CMOS settings that resets your system to  
its default.  
Warning: It is strongly recommended that you avoid making any changes to the chipset  
defaults. These defaults have been carefully chosen by both Award and your system  
manufacturer to provide the absolute maximum performance and reliability. Changing  
the defaults could cause the system to become unstable and crash in some cases.  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
STANDARD CMOS FEATURES  
"Standard CMOS Features" choice allows you to record some basic hardware configurations in your  
computer system and set the system clock and error handling. If the motherboard is already installed in a  
working system, you will not need to select this option. You will need to run the Standard CMOS option,  
however, if you change your system hardware configurations, the onboard battery fails, or the configura-  
tion stored in the CMOS memory was lost or damaged.  
At the bottom of the menu are the control keys for use on this  
menu. If you need any help in each item field, you can press the  
<F1> key. It will display the relevant information to help you. The memory display at the lower right-hand  
side of the menu is  
read-only. It will adjust automatically according to the memory changed. The following describes each  
item of this menu.  
Date  
The date format is:  
Day : Sun to Sat  
Month :  
1 to 12  
Date : 1 to 31  
Year : 1999 to 2099  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
To set the date, highlight the "Date" field and use the PageUp/ PageDown or +/- keys to set the current  
time.  
Time  
The time format is: Hour :  
00 to 23  
Minute :  
Second :  
00 to 59  
00 to 59  
To set the time, highlight the "Time" field and use the <PgUp>/  
<PgDn> or +/- keys to set the current time.  
IDE Channel Master/Slave  
The onboard SerialATAconnectors provide Primary and Secondary channels for connecting up to four  
SerialATAhard disks. Each channel can support up to two hard disks; the first is the "Master" and the  
second is the "Slave".  
Press <Enter> to configure the hard disk. The selections includeAuto, Manual, and None. Select  
'Manual' to define the drive information manually. You will be asked to enter the following items.  
Capacity :  
Cylinder :  
Capacity/size of the hard disk drive  
Number of cylinders  
Head :Number of read/write heads Precomp : Write precompensation Landing Zone : Landing zone  
Sector : Number of sectors  
TheAccess Mode selections are as follows:  
CHS (HD < 528MB)  
LBA (HD > 528MB and supports Logical Block Addressing)  
Large (for MS-DOS only)  
Auto  
Remarks: The main board supports one serialATAports and are represented in this setting as IDE Chan-  
nel 2.  
Video  
This field selects the type of video display card installed in your system. You can choose the following  
video display cards:  
EGA/VGA For EGA, VGA, SEGA, SVGA or PGA monitor adapters. (default)  
CGA 40  
CGA 80  
MONO  
Power up in 40 column mode.  
Power up in 80 column mode.  
For Hercules or MDA adapters.  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
Halt On  
This field determines whether or not the system will halt if an error is detected during power up.  
All errors  
Whenever theBIOS detects a non-fatal error, the system will stop and you will be  
prompted.  
No errors  
The system boot will not be halted for any error that may be detected.  
All, But Keyboard The system boot will not be halted for a keyboard error; it will stop for all other  
errors  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
ADVANCED BIOS FEATURES  
This section allows you to configure and improve your system and allows you to set up some system  
features according to your preference.  
CPU Feature  
Press Enter to configure the settings relevant to CPU Feature.  
Hard Disk Boot Priority  
With the field, there is the option to choose, aside from the hard disks connected, "Bootable add-in  
Cards" which refers to other external devices.  
Virus Warning  
If this option is enabled, an alarm message will be displayed when trying to write on the boot sector or on  
the partition table on the disk, which is typical of the virus.  
CPU L1 and L2 Cache  
Cache memory is additional memory that is much faster than conventional DRAM (system memory).  
CPUs from 486-type on up contain internal cache memory, and most, but not all, modern PCs have  
additional (external) cache memory. When the CPU requests data, the system transfers the requested  
data from the main DRAM into cache memory, for even faster access by the CPU. These items allow you  
to enable (speed up memory access) or disable the cache function. By default, these items are  
Enabled.  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
CPU L3 Cache  
Enabled or Disabled  
Quick Power On Self Test  
When enabled, this field speeds up the Power On Self Test (POST) after the system is turned on. If it is set  
to Enabled, BIOS will skip some items.  
First/Second/Third Boot Device  
These fields determine the drive that the system searches first for an operating system. The options  
available include LS120, Hard Disk, CDROM, ZIP100, USB-Floppy, USB-ZIP, USB-CDROM, LAN  
and Disable.  
Boot Other Device  
These fields allow the system to search for an OS from other devices other than the ones selected in  
the First/Second/Third Boot Device.  
Boot Up NumLock Status  
This allows you to activate the NumLock function after you power up the system.  
GateA20 Option  
This field allows you to select how GateA20 is worked. GateA20  
is a device used to address memory above 1 MB.  
Typematic Rate Setting  
When disabled, continually holding down a key on your keyboard will generate only one instance. When  
enabled, you can set the two typematic controls listed next. By default, this field is set to Disabled.  
Typematic Rate (Chars/Sec)  
When the typematic rate is enabled, the system registers repeated keystrokes speeds. Settings  
are from 6 to 30 characters per second.  
Typematic Delay (Msec)  
When the typematic rate is enabled, this item allows you to set the time interval for displaying the first  
and second characters. By default, this item is set to 250msec.  
Security Option  
This field allows you to limit access to the System and Setup. The default value is Setup. When you  
select System, the system prompts for the User Password every time you boot up. When you select  
Setup, the system always boots up and prompts for the Supervisor Password only when the Setup utility  
is called up.  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
APIC Mode  
APIC stands forAdvanced Programmable Interrupt Controller. The default setting is Enabled.  
MPS Version Control for OS  
This option is specifies the MPS (Multiprocessor Specification) version for your operating system. MPS  
version 1.4 added extended configuration tables to improve support for multiple PCI bus configurations and  
improve future expandability. The default setting is 1.4.  
OS Select for DRAM > 64MB  
This option allows the system to access greater than 64MB of DRAM memory when used with OS/2 that  
depends on certain BIOS calls to access memory. The default setting is Non-OS/2.  
Report No FDD For WIN 95  
If you are using Windows 95/98 without a floppy disk drive, select  
Enabled to release IRQ6. This is required to pass Windows  
95/98's SCT test. You should also disable the Onboard FDC Controller in the Integrated Peripherals screen  
when there's no floppy drive in the system. If you set this feature to Disabled, the BIOS will not report the  
missing floppy drive to Win95/98.  
Full screen Logo Show  
The screen logo appears full of the monitor screen when the system is boot up. The default setting is  
Enabled.  
Small Logo (EPA) Show  
The EPAlogo appears at the right side of the monitor screen when the system is boot up. The default  
setting is Disabled.  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
ADVANCED CHIPSET FEATURES  
This Setup menu controls the configuration of the chipset.  
System BIOS Cacheable  
The setting of Enabled allows caching of the system BIOS ROM at F000h-FFFFFh, resulting  
in  
better system  
may result.  
performance. However, if any program writes to this memory area, a system error  
Memory HoleAt 15M-16M  
In order to improve performance, certain space in memory can be reserved for ISA cards. This memory  
must be mapped into the memory space below 16 MB. The choices are Enabled and Disabled.  
PCI Express Root Port Func  
By default.  
VGA Setting  
The fields under the VGA Setting and their default settings are: PEG/On Chip VGA Control: Onchip VGA  
On-Chip Frame Buffer Size: 8MB DVMT Mode: DVMT  
DVMT/Fixed Memory Size: 128MB Boot Display:Auto  
Panel Scaling:Auto  
Panel Number: 4  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
INTEGRATED PERIPHERALS  
This section sets configurations for your hard disk and other integrated peripherals.  
OnChip IDE Device  
IDE HDD Block Mode  
This field allows your hard disk controller to use the fast block mode to transfer data to and from your  
hard disk drive.  
IDE DMA transfer access  
This field allows your hard disk controller to use the fast block mode to transfer data to and from your  
hard disk drive.  
On-Chip SerialATASetting  
The fields under the SATA setting includes On-Chip Serial ATA(Auto), PATAIDE Mode (Secondary)  
and SATA Port (PO, P2 is Primary).  
OnChip Primary/Secondary PCI IDE  
The integrated peripheral controller contains an IDE interface with support for two IDE channels.  
Select Enabled to activate each channel separately.  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
ONCHIP SUPER IO DEVICE  
Power ON Function  
This field is related to how the system is powered on - such as with the use of conventional power button,  
keyboard or hot keys. The default is BUTTON ONLY.  
Onboard Serial Port  
These fields allow you to select the onboard serial ports and their addresses. The default values for these  
ports are:  
Serial Port 1 3F8/IRQ4  
Serial Port 2 2F8/IRQ3  
UART Mode Select  
This field determines the UART 2 mode in your computer. The default value is Normal. Other options  
include IrDAandASKIR.  
PWRONAfter PWR-Fail  
This field sets the system power status whether on or off when power returns to the system from a  
power failure situation.  
USB Device Setting  
USB 1.0 Controller  
The options for this field are Enabled and Disabled. By default, this field is set to Enabled.  
USB 2.0 Controller  
The options for this field are Enabled and Disabled. By default, this field is set to Enabled. In order to  
use USB 2.0, necessary OS drivers must be installed first. Please update your system to Windows 2000  
SP4 or Windows XP SP2.  
USB Operation Mode  
The options for this field are Full/Low speed and High speed. By default, this field is set to High speed.  
USB Keyboard Function  
The options for this field are Enabled and Disabled. By default, this field is set to Enabled.  
USB Mouse Function  
The options for this field are Enabled and Disabled. By default, this field is set to Enabled.  
USB Storage Function  
The options for this field are Enabled and Disabled. By default, this field is set to Enabled.  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
POWER MANAGEMENT SETUP  
ACPI Function  
Enable this function to supportACPI (Advance Configuration and  
Power Interface).  
ACPI Suspend  
The default setting of theACPI Suspend mode is S3(STR).  
RUN VGABIOS if S3 Resume  
The default setting of this field isAuto.  
Power Management  
This field allows you to select the type of power saving management modes. There are three  
selections for Power Management.  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
User Define  
Each of the ranges is from 1 min. to 1hr. Except for HDD Power Down which ranges  
from 1 min. to 15 min.  
Min. Power Saving Minimum power management  
Max. Power Saving Maximum power management.  
Video Off Method  
This field defines the Video Off features. There are three options.  
Blank Screen  
V/H SYNC + Blank Blank the screen and turn off vertical and horizontal scanning.  
DPMS Default setting, allows BIOS to control the video display.  
Writes blanks to the video buffer.  
Video Off In Suspend  
When enabled, the video is off in suspend mode. The default setting is Yes.  
Suspend Type  
The default setting for the Suspend Type field is Stop Grant.  
Modem Use IRQ  
This field sets the IRQ used by the Modem. By default, the setting is 3.  
Suspend Mode  
When enabled, and after the set time of system inactivity, all devices except the CPU will be shut off. By  
default, the setting is Disabled.  
HDD Power Down  
When enabled, and after the set time of system inactivity, the hard disk drive will be powered down  
while all other devices remain active.  
Soft-Off by PWR-BTTN  
This field defines the power-off mode when using anATX power supply. The Instant Off mode allows  
powering off immediately upon pressing the power button. In the Delay 4 Sec mode, the system powers  
off when the power button is pressed for more than four seconds or enters the suspend mode when  
pressed for less than 4 seconds.  
Wake up by PCI Card  
By default, this field is Enabled.  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
Power On by Ring  
This field enables or disables the power on of the system through the modem connected to the  
serial port or LAN.  
USB KB Wake-Up From S3  
By default, this field is Disabled.  
Resume by Alarm  
This field enables or disables the resumption of the system operation. When enabled, the  
user is allowed to set the Date and Time.  
Reload Global Timer Events  
The HDD, FDD, COM, LPT Ports, and PCI PIRQ are I/O events that can prevent the system from  
entering a power saving mode or can awaken the system from such a mode. When an I/O de-  
vice wants to gain the attention of the operating system, it signals this by causing an IRQ to  
occur. When the operating system is ready to respond to the request, it interrupts itself and  
performs the service.  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
PNP/ PCI CONFIGURATIONS  
This option configures the PCI bus system.All PCI bus systems on the system use INT#, thus all in-  
stalled PCI cards must be set to this value.  
Init Display First  
The default setting is Onboard.  
Reset Configuration Data  
This field allows you to determine whether to reset the configuration data or not. The default  
value is Disabled.  
Resources Controlled by  
This PnP BIOS can configure all of the boot and compatible devices with the use of a PnP operat-  
ing system such as Windows 95.  
PCI/VGA Palette Snoop  
Some non-standard VGA display cards may not show colors properly. This field allows you to  
set whether or not MPEG ISA/VESA VGA cards can work with PCI/VGA. When this field is en-  
abled, a PCI/VGA can work with an MPEG ISA/VESA VGA card. When this field is disabled, a PCI/  
VGA cannot work with an MPEG ISA/VESA card.  
Maximum Payload Size  
The default setting of the PCI Express Maximum Payload Size is 128.  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
PC HEALTH STATUS  
This section shows the parameters in determining the PC Health Status. These  
parameters include temperatures, fan speeds and voltages.  
CPU Warning Temperature  
This field allows the user to set the temperature so that when the temperature is  
reached, the system sounds a warning. This function can help prevent damage to  
the system that is caused by overheating.  
CPU Smart Fan Temperature  
This field allows the user to set the temperature so that when the temperature is  
reached, the smart fan will speed up to cool the CPU temperature.  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
Load Fail-Safe Defaults  
This option allows you to load the troubleshooting default values permanently stored in  
the BIOS ROM. These default settings are non-optimal and disable all high-perfor-  
mance features.  
Load Optimized Defaults  
This option allows you to load the default values to your system configuration. These  
default settings are optimal and enable all high performance features.  
Set Supervisor Password  
These two options set the system password. Supervisor Password sets a password  
that will be used to protect the system and Setup utility. User Password sets a  
password that will be used exclusively on the system. To specify a password, high-  
light the type you want and press <Enter>. The Enter Password: message prompts on  
the screen. Type the password, up to eight characters in length, and press <Enter>.  
The system confirms your password by asking you to type it again. After setting a  
password, the screen automatically returns to the main screen.  
To disable a password, just press the <Enter> key when you are prompted to enter the  
password. A message will confirm the password to be disabled. Once the password  
is disabled, the system will boot and you can enter Setup freely.  
Save & Exit Setup  
This option allows you to determine whether or not to accept the modifications. If you  
type "Y", you will quit the setup utility and save all changes into the CMOS memory. If  
you type "N", you will return to Setup utility.  
Exit Without Saving  
Select this option to exit the Setup utility without saving the changes you have made  
in this session. Typing "Y" will quit the Setup utility without saving the modifications.  
Typing "N" will return you to Setup utility.  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
APPENDIX  
A. JUMPER SETTINGS AND CONNECTIONS  
This appendix gives the definitions and shows the positions of jumpers, headers and connectors. All of  
the configuration jumpers on MPC6171A/ MPC6171B are in the proper position.  
Note: Some of jumpers or connectors will be removed base on system configuration.  
A-1 Jumper location and list  
In general, jumpers on the single board computer are used to select options for certain features. To  
select any option, cover the jumper cap over (SHORT) or remove (NC) it from the jumper pins accord-  
ing to the following instructions.  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
A-2 Connectors location and list  
The connectors on the PCBA of MPC6171A/ MPC6171B are used to connect external devices such  
as hard disk drives, printers, keyboard, serial ports, etc. Specifically, the PCBA of MPC6171A/  
MPC6171B has the following connectors:  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
B. VESA MOUNTING  
The MPC6171A/ MPC6171B also provides standard VESA mounting to help system integrators  
conveniently integrate the panel PC into their system.  
Never use any other mounting brackets except those provided by Wincomm to prevent the unreliable  
fixing of MPC6171A/ MPC6171. VESA mount installation should be carried out by a professional  
technician. Please contact the service technician or your retailer if you need this service.  
Installation instructions follow:  
1. The wall-mounting attachment is comprised of two parts: one back bracket, and one mounting  
bracket.  
2. First attach the back bracket to the rear cover of the MPC6171A/ MPC6171, securing it in place  
with four of the Phillips-head screws provided.  
3. Attach the mounting bracket to the wall or another flat surface. The back bracket slides vertically  
from the top into the mounting bracket. It can be secured to the mounting bracket by screwing four of  
the Phillips-head screws provided through the corresponding holes at the tops of the mounting  
bracket.  
Warning:  
Be sure to secure the screws of the mounting bracket tightly. Injuries could result if the MPC6171A/  
MPC6171 isn't properly secured to the mounting bracket.  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MPC 6171  
17” Medical Grade Panel PC  
Core 2 Duo embedded system  
© Copyright 2011 Acnodes, Inc.  
All rights reserved. Product description and product specifications  
are subject to change without notice. For latest product information,  
661 Brea Canyon Rd., Suite 3  
Walnut, CA 91789  
tel: 909.598.7388, fax: 909.598.0218  
Download from Www.Somanuals.com. All Manuals Search And Download.  

2Wire Gas Grill C 3020 ZOOM User Manual
3M VCR 800a User Manual
Adagio Teas Electronic Keyboard PDP100 User Manual
Aiphone Home Theater Screen KCW M User Manual
Aiphone Intercom System 0311 A OI User Manual
AllerAir Air Cleaner 5000 Vocarb User Manual
Amana Range ACS7270A User Manual
American DJ DJ Equipment Dr DMX User Manual
Atlona TV Cables AT HDMI250SR User Manual
Behringer Guitar 3 User Manual