Ace Hardware Water Pump R 30 T7 User Manual

INSTALLATION MANUAL  
JET TANK SYSTEM  
EASTERN  
STANDARD  
TIME  
CONSUMER HOT-LINE: 1-800-942-3343 • MONDAY - FRIDAY • 7 AM to 5 PM  
JET TANK  
®
R
SYSTEM  
pump only  
with 7-gallon  
diaphragm  
pressure  
tank  
MODEL R-30-T7  
1/3 Horse Power  
Convertible Pump  
WARRANTY  
PRODUCT DEFECTS  
COVERED TWELVE  
MONTHS FROM  
DATE OF PURCHASE  
OR EIGHTEEN  
MONTHS FROM  
DATE OF MANUFAC-  
TURE, WHICHEVER  
COMES FIRST. RE-  
CEIPT AND PROD-  
UCT DATE CODE  
REQUIRED FOR  
WARRANTY CLAIM.  
WATER ACE PUMP COMPANY • ASHLAND, OHIO 44805-1969  
23833A343  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FINDING THE DEPTH OF YOUR WELL  
IMPORTANT SELECT  
CORRECT VOLTAGE  
The jet tank system installs differently depending  
on the depth of your well. Tie a small but heavy  
weight to the end of a piece of string (be sure there is  
enough string; some wells are very deep). Lower the  
weight into the well until it reaches the bottom. Take up  
the slack and mark the string at ground level. Pull the  
weight out of the well and measure from the bottom of  
the weight to the ground level mark. This is the depth  
of your well. Subtract five feet from the depth of your  
well. This number should not exceed the maximum  
rated depth for your pump. If it does, it will greatly  
hinder or prevent the proper operation of the pump.  
GRD  
VOLTAGE SELECTOR  
AT REAR OF MOTOR  
(USE NEEDLE  
UNGROUNDED  
LINE  
NOSE PLIERS)  
230V  
115V  
PULL SELECTOR -  
ROTATE - REINSERT  
L1  
L2  
HIGH  
LOW  
VOLTAGE VOLTAGE  
230  
VOLTAGE  
SELECTOR  
TERMINAL BOARD  
115  
115V OR 230V OPERATION  
USE COPPER CONDUCTORS ONLY  
Your pump is equipped with one of two types of dual  
voltage motors. Follow the instructions to wire the  
motor for the proper voltage. The voltage of the pump  
must match the voltage of the power supply.  
WIRE SELECTION GUIDE  
WIRING YOUR PUMP  
Remove the cover from the pressure switch. Connect  
the bare copper ground to the ground screw in the  
pressure switch. Connect the power supply to the  
terminals marked "Line" in the diagram below.  
NAME  
VOLTAGE PLATE  
AMPS  
MAX. WIRE LENGTH USING AWG SIZE  
#14  
#8  
#12  
#10  
115  
230  
10.6  
5.3  
118  
189  
296  
464  
475  
756  
1184  
1857  
LINE  
FUSE AND CIRCUIT  
BREAKER SIZE GUIDE  
MOTOR  
LOW PEAK - CART. TYPE  
FUSETRON - CART. TYPE  
FUSTAT - PLUG TYPE*  
STANDARD LINE  
PLUG FUSE*  
CIRCUIT BREAKER  
MOTOR  
LINE  
115V  
230V  
115V  
230V  
115V  
230V  
20  
10  
12  
6-1/4  
20  
15  
GROUND  
*For circuits not over 150 volts to ground.  
23833A343  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
DRAINING FOR SERVICING OR FOR WINTER  
PIPING  
The pump should be drained before it is disconnected  
for servicing or if it is in danger of freezing. To drain:  
Remove drain plug from bottom of pump case.  
Remove discharge tee to vent the pump.  
Plastic PVC pipe is shown in the illustrations, but  
galvanized steel pipe may be used if desired. All piping  
must be clean and free of all foreign matter to prevent  
clogging. ALL JOINTS AND CONNECTIONS IN THE  
WELL ASSEMBLY MUST BE AIRTIGHT. Even a pin-  
hole leak will prevent the proper operation of the pump  
(this is the most common problem). Use thread com-  
pound on all threaded joints unless specified otherwise.  
Drain all piping to a point 3 feet below ground level.  
SHALLOW WELL PUMP INSTALLATION (4" DIAMETER CASED WELL)  
For wells 25 feet or less in depth, the ejector may be  
attached to the front of the tank-mounted jet pump. For  
lower depths, the ejector must be placed down inside  
the well (see DEEP WELL PUMP INSTALLATION). All  
materials with part numbers are quality Water Ace parts.  
One can PVC cement (read instructions carefully)  
One can thread compound (read instructions carefully)  
Two male 1-1/4" PVC adapters  
Enough rigid 1-1/4" PVC pipe and couplings to reach  
from bottom of well to pump.  
One 4" well seal #RWS4-1012 with vent plug  
One 1-1/4" PVC elbow  
General Materials  
One Jet Tank System #R-30-T7. Includes: 1/3 HP  
jet pump mounted on a 7-gallon diaphragm pressure  
tank, pressure gauge, and twin ejector with gasket,  
bolts, venturi tubes, and foot valve.  
Tools Needed for all pump installations  
Pipe wrench, pipe clamp, crescent wrench, slot screw-  
driver, 24-tooth hacksaw, knife or round file.  
REMINDER: ALL JOINTS AND CONNECTIONS MUST BE AIRTIGHT. A SINGLE PIN-  
HOLE LEAK WILL PREVENT THE PROPER OPERATION OF THE PUMP. USE THREAD  
COMPOUND ON ALL THREADED CONNECTIONS UNLESS SPECIFIED OTHERWISE.  
S3TEP Cement as many coup-  
S1TEP Thread 1-1/4" male PVC  
lings and sections of  
rigid PVC pipe as it  
adapter into foot valve.  
Hand tighten, then tighten  
1/4 turn with crescent  
wrench.  
1-1/4"  
MALE PVC  
ADAPTER  
takes to equal the depth  
of your well minus five  
feet, then firmly clamp  
the assembly with a  
pipe clamp to prevent  
assembly from sliding  
down into the well.  
FOOT  
VALVE  
Subtract five feet from the  
depth of your well (See  
page 3 "Finding the Depth  
of Your Well"). This is the  
S2TEP  
PVC  
PIPE  
SECTION  
total length of rigid PVC pipe and  
couplings to cement onto the 1-1/4"  
male PVC adapter. Cement one  
section of rigid PVC pipe to the PVC  
adapter which is connected to the  
foot valve, then lower the whole  
assembly into the well, foot valve  
first. Firmly clamp the end of the  
rigid PVC pipe with a pipe clamp to  
prevent the assembly from sliding  
down into the well.  
1-1/4"  
MALE PVC  
ADAPTER  
FOOT  
VALVE  
23833A343  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
STEP 9  
Remove pipe clamp and  
slide Well Seal #RWS4-12  
over PVC pipe and onto well  
casing. Position assembly  
maximum water flow is obtained without  
pressure dropping to zero. If pressure falls  
completely, retighten adjustment screw and  
read-just. Steady pressure must not be less  
S4TEP  
CONT'D  
APPROX.  
12" OF  
PVC PIPE  
PROTRUDING  
FROM WELL  
SEAL  
than 24 lbs. for the R520. If no pressure shows:  
Stop motor, remove pressure gauge plug from pressure  
regulator, add more water, and try again.  
so twelve inches of PVC pipe pro-  
trude from well seal. Alternately turn  
bolts on well seal counterclockwise  
until rubber gaskets are tight against  
well casing and PVC pipe.  
WELL  
SEAL  
#RWS4-12  
Thread pressure  
gauge plug back  
STEP  
into discharge  
tee. Thread  
pressure gauge into pres-  
sure gauge plug. Make  
sure all connections are  
tightly sealed. Place a  
large basin beneath dia-  
phragm tank outlet. Start  
motor. If pump is off-set  
from well 4 feet or more, it  
may take a few minutes  
for pump to prime. Failure to prime in 5 minutes:  
Stop motor, remove pressure gauge plug from dis-  
charge tee, add more water, try again. Allow pump to  
run long enough to clear the well of sand or dirt and to  
insure well will not run dry. Stop motor.  
Cement 1-1/4" PVC elbow  
onto PVC pipe protruding  
from well seal. If desired,  
STEP  
10  
1-1/4"  
PVC  
ELBOW  
5
some length may be cut off  
of PVC pipe before cementing  
elbow. Smooth inside of any cut  
PVC pipe with file or knife.  
TOP OF  
PVC PIPE  
PROTRUDING  
FROM WELL  
SEAL  
Open ejector  
pack included  
VENTURI  
TUBE  
S6TEP  
BOLTS  
GASKET  
EJECTOR  
with your jet sys-  
tem. The ejector  
has two holes in its top.  
Thread the venturi tube  
(part #25881A281 stamped on the side) into larger hole  
until snug. Put gasket over venturi tube so openings in  
gasket line up with openings in ejector.  
Connect the 1" tank outlet to the service line.  
Total installation should look like the drawing  
below.  
STEP  
Secure ejector and  
gasket to front of tank-  
mounted pump with  
bolts provided. Thread  
a 1-1/14" male PVC  
adapter into front of  
ejector.  
S7TEP  
11  
EJECTOR  
MALE PVC  
ADAPTER  
Cement as much PVC pipe and couplings  
needed to connect PVC elbow to male PVC  
adapter in front of ejector. The diaphragm  
pressure tank is preset to 30 PSI. Reset  
pressure to 18 PSI using a tire gauge. This is vital to  
proper operation of the system.  
S8TEP  
COMPLETE  
SHALLOW WELL  
INSTALLATION  
Place a large bucket  
beneath the pressure  
regulator outlet. Start  
STEP  
PRESSURE  
PRESSURE  
REGULATOR  
GAUGE  
ADJUSTMENT  
9
motor. Turn regulator  
adjustment screw down tight.  
If pump is properly primed a  
high pressure will immediately  
show on the pressure gauge.  
With pump operating at high  
pressure, slowly unscrew reg-  
ulator adjustment screw until  
23833A343  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
DEEP WELL PUMP INSTALLATION (4" DIAMETER CASED WELL)  
One 1-1/4" close nipple  
One 1" x 4" nipple  
One 1-1/4" x 5" nipple  
Two 1" female PVC adapters  
One 1" male PVC adapter  
Two 1-1/4" male PVC adapters  
Enough rigid 1-1/4" PVC pipe and couplings to reach  
from bottom of well to pump (delivery pipe)  
Enough rigid 1" PVC pipe and couplings to reach  
from bottom of well to pump (pressure pipe))  
One well seal #RWS4-1012  
For wells over 25, but not exceeding 60 feet in depth,  
the twin ejector must be installed down inside the well  
rather than attached to the front of the pump. Materials  
with part numbers are quality Water Ace parts.  
General Materials  
One Jet Tank System #R-30-T7. Includes: 1/3 HP  
jet pump mounted on a 7-gallon diaphragm pressure  
tank, pressure gauge, and twin ejector with  
gasket, bolts, venturi tubes, and foot valve.  
One can PVC cement (read instructions carefully)  
One can thread compound (read instructions carefully)  
One 1-1/4" PVC elbow  
One 1" PVC elbow  
REMINDER: ALL JOINTS AND CONNECTIONS MUST BE AIRTIGHT. A SINGLE PIN-  
HOLE LEAK WILL PREVENT THE PROPER OPERATION OF THE PUMP. USE THREAD  
COMPOUND ON ALL THREADED CONNECTIONS UNLESS SPECIFIED OTHERWISE.  
Lower the assembly into  
S1TEP Thread 1-1/4" close nipple  
S5TEP  
into foot valve. Thread the  
the well, foot valve first.  
Use a pipe clamp to  
prevent assembly for  
sliding down into well.  
Cement as many  
couplings and sections  
of rigid PVC pipe on  
both sides of ejector as  
it takes to equal the  
depth of your well minus  
five feet, then firmly  
clamp assembly with a  
pipe clamp to prevent it  
from sliding down into  
the well.  
EJECTOR  
other end of 1-1/4" close  
nipple into bottom of twin  
ejector. Hand tighten, then  
tighten 1/4 turn with pipe  
wrench.  
1-1/4"  
CLOSE  
NIPPLE  
FOOT  
VALVE  
The ejector has two holes in  
the top of it. Thread venturi  
tube (part #25881A281  
stamped on the side) into  
S2TEP  
1" X 5"  
NIPPLE  
larger hole until snug. Thread 1" x  
5" nipple into smaller hole. Only  
hand tighten venturi tube. Tighten  
nipple 1/4 turn with pipe wrench.  
VENTURI  
TUBE  
EJECTOR  
Thread a 1-1/4" male PVC  
adapter over the venturi  
tube and into ejector.  
Thread a 1" female PVC  
adapter onto 1" x 5" nipple.  
Tighten adapters 1/4 turn  
with crescent wrench.  
S3TEP  
1" FEMALE  
PVC  
ADAPTER  
1-1/4" MALE  
PVC  
ADAPTER  
Remove pipe clamp and  
slide well seal #RWS4-1012  
over PVC pipes and onto  
well casing. DO NOT let  
S6TEP  
12" OF  
PVC PIPE  
PROTRUD-  
ING FROM  
WELL  
Subtract five feet from the  
depth of your well. This is  
the total length of PVC pipe  
STEP  
1"  
PVC  
PIPE  
1-1/4"  
PVC  
PIPE  
SEAL  
assembly slide down into well. Posi-  
tion assembly so that twelve inches  
of PVC pipes protrude from well  
seal. Using crescent wrench, turn  
bolts on well seal counterclockwise  
until rubber gaskets are tight against  
the well casing and the PVC pipes.  
4
and couplings to cement  
onto both the 1-1/4" male and 1"  
female PVC adapters. Cement a  
section of PVC pipe to each adapter.  
WELL SEAL  
#RWS4-1212  
23833A343  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cut 1" pipe 2" shorter than  
the 1-1/4" pipe. Smooth  
rough edges. Cement 1"  
and 1-1/4" PVC elbows to  
pipes protruding from the  
well seal.  
STEP  
1-1/4" PVC  
ELBOW  
1" PVC  
ELBOW  
7
1" PIPE 2"  
SHORTER  
THAN 1-1/4"  
PIPE  
Thread 1-1/4" male PVC  
adapter into top hole in front  
of tank-mounted pump.  
Thread 1" x 4" nipple into  
bottom hole in front of pump.  
STEP  
1 1/4" MALE  
PVC  
ADAPTER  
8
1" x 4"  
NIPPLE  
Thread the 1" female PVC  
adapter onto the 1" x 4"  
nipple.  
STEP  
1 1/4"  
FEMALE  
PVC  
COMPLETE  
DEEP WELL  
INSTALLATION  
9
ADAPTER  
STEP  
10  
1 1/4" PVC PIPE  
Cement as  
many sec-  
tions and  
1" PVC PIPE  
CAUTION: If you change pressure switch settings,  
set the cut-off pressure low enough to shut off the  
pump. The recommended pressure is 2 PSI below  
your pump cut-off pressure. Example: if a 20-40 PSI  
pressure switch is being used, tank pressure should  
be 18 PSI. If a valve shuts off and the cut-off setting  
is too high, the pump will run continuously without  
water flow causing overheating and serious damage.  
couplings of  
rigid 1" and  
1-1/4" PVC pipe needed to connect the 1" female PVC  
adapter and the 1-1/4" male PVC adapter to the 1" and  
1-1/4" PVC elbows. The diaphragm pressure tank is  
factory preset to 30 PSI. Reset the pressure to 18  
PSI using a tire gauge. This is vital to the proper  
operation of the system. Remove pressure gauge plug.  
Place a large bucket  
beneath the pressure  
regulator outlet. Start  
motor. Turn regulator  
STEP  
REGULATOR  
ADJUSTMENT  
SCREW  
11  
adjustment screw down tight.  
If pump is properly primed a  
high pressure will immediately  
show on the pressure gauge.  
With pump operating at high  
pressure, slowly unscrew reg-  
ulator adjustment screw until  
maximum water flow is obtain-  
ed without pressure dropping to zero. If pressure falls  
completely, retighten adjustment screw and re-adjust.  
Steady pressure must not be less than 24 lbs. for the  
R520 and 32 lbs. for the R100. If no pressure shows:  
Stop motor, remove pressure gauge plug from pressure  
regulator, add more water, and try again. Complete  
installation should look like the drawing to the right.  
23833A343  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING CHECKLIST  
(CAUTION: SHUT OFF POWER TO PUMP)  
PROBLEM  
POSSIBLE CAUSES  
Not enough water. Stop motor, remove pressure gauge plug, and fill case with water.  
Pump wired incorrectly.  
Plugged venturi tube or nozzle.  
Pump will not prime  
Foot valve is sitting in sand or mud, or is stuck shut, or leaks.  
Low well water level. In deep wells, the ejector as well as the foot valve must be below  
water level.  
Leaks. Check all connections for airtightness.  
Low well water level. Use a water-level tester while pump is operating.  
Plugged venturi tube, nozzle, or impeller parts.  
Pump delivers water  
for a period of time,  
then stops pumping  
Plugged venturi or nozzle.  
Faulty pressure gauge resulting in false readings.  
In deep wells, the operating pressure may be too high.  
Low well water level. Use a water-level tester while pump is operating.  
Over-submergence of ejector. In deep wells, if ejector is more than 10 feet below  
pumping level, pumping capacity is reduced.  
Pump does not de-  
liver rated capacity  
In deep wells, the ejector may have improper size and depth setting.  
Motor voltage does not match power supply voltage. See pages 2 and 3.  
Improper wire size. See Wire Size Guide on page 3.  
Impeller is rubbing against pump case.  
Motor overheats and  
shuts off (overload)  
Impeller neck is worn.  
Defective pressure switch.  
The tube connecting the two brass fittings may be clogged.  
Tank precharge pressure too high. Tank precharge pressure must be 1-2 pounds less  
than switch turn-on setting.  
Pump delivers water  
but will not shut off  
In deep wells, the water level may be going below limit of ejector. Use water-level  
tester while pump is operating.  
Pressure switch  
turns on and off  
every few seconds  
Galvanized storage tank is waterlogged.  
Leaky foot valve.  
Too much tank pressure.  
Motor fails or does  
not operate properly  
If within Warranty, return pump/motor unit to place of purchase (with proof of purchase)  
for exchange.  
LIMITED WARRANTY  
WATER ACE PUMP CO. will repair or replace for the original user any portion of a new  
Water Ace product which proves defective due to materials or workmanship of WATER ACE  
PUMP CO. Contact the nearest authorized WATER ACE PUMP CO. dealer for warranty  
service. WATER ACE PUMP CO. shall possess the sole right to determine whether to repair  
or replace defective equipment, parts or components. THIS WARRANTY DOES NOT  
COVER DAMAGE DUE TO LIGHTNING OR OTHER CONDITIONS BEYOND THE  
CONTROL OF WATER ACE PUMP CO.  
PRODUCT IMPROVEMENTS: WATER ACE PUMP CO. reserves the right to change or  
improve its products or any component without obligation to provide such a change or  
improvement for units previously sold and/or shipped.  
WARRANTY EXCLUSIONS: After the expiration of this warranty period, THERE WILL BE  
NO WARRANTIES INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR  
FITNESS FOR ANY PARTICULAR PURPOSE ON ANY SPECIFIC WATER ACE PUMP  
PRODUCT. Some states do not allow limitations on how long an implied warranty lasts, so  
the above limitation may not apply to you. No warranties or representations at any time  
made by any representative of WATER ACE PUMP CO. shall vary or expand the provisions  
hereof.  
PUMPS: Warranted 12 months from date of purchase or 18 months from date of  
manufacture, whichever occurs first. Receipt and product date code required for warranty  
claim.  
LABOR & COSTS: WATER ACE PUMP CO. shall IN NO EVENT be liable for the cost of  
field labor or other charges incurred by any customer in removing and/or reaffixing any  
WATER ACE PUMP product. part or component.  
LIABILITY LIMITATION: IN NO EVENT SHALL WATER ACE PUMP CO. BE LIABLE FOR  
CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES RESULTING FROM OR  
RELATED IN ANY MANNER TO ANY WATER ACE PUMP PRODUCT OR PARTS. Some  
states do not allow the exclusion or limitation of incidental or consequential damages, so the  
above limitation may not apply to you. This Warranty gives you specific legal rights. You  
may have other rights which vary from state to state. In the absence of suitable proof of  
purchase date, the effective date of this warranty will be based upon the date of manufacture  
plus 180 days.  
THIS WARRANTY WILL NOT APPLY: (a) to defects or malfunctions resulting from failure to  
properly install, operate, or maintain the unit in accordance with printed instructions provided;  
(b) to failures resulting from abuse, accident, or negligence; (c) to normal maintenance  
services and the parts used in connection with such service; (d) to units which are not  
installed in accordance with applicable local codes, ordinances, and good trade practices; (e)  
if the unit is moved from its original installation location; (f) if unit is used for purposes other  
than for what it was designed and manufactured.  
Direct all Notices, etc. to: Product Warranty and Return Dept., WATER ACE PUMP CO., 1101  
Myers Parkway, Ashland, OH 44805-1969  
23833A343  
Water Ace Pump Co. • 1101 Myers Parkway • Ashland, Ohio 44805-1969  
7/95  
Download from Www.Somanuals.com. All Manuals Search And Download.  
REPLACEMENT PARTS  
1
12  
2
3 25  
4
16  
17  
14  
24  
21  
23  
15  
18  
9
13, 19, 20  
10  
11  
16  
7
JET TANK SYSTEM  
MODEL R-30-T7  
22  
REF.  
NO.  
REF.  
NO.  
PART NUMBER  
DESCRIPTION  
PART NUMBER  
DESCRIPTION  
1
2
3
4
5
6
7
8
9
20929D501  
05003A000  
24349B000  
23188A005  
05004A015  
05004A087  
05126A013  
05916A171  
05920A173  
PUMP  
14 24859C500  
15 19101A019  
16 14740A001  
17 15760A510  
18 19277A001  
19 19100A029  
20 19109A012  
21 23188A002  
22 25579A108  
23 08728A006  
24 25881A281  
25 23188A001  
EJECTOR BODY  
SCREW (2 required)  
HOSE CLAMP (2 required)  
REGULATOR SWITCH  
GASKET  
PRESSURE GAUGE  
REGULATOR  
HOSE ADAPTER  
BUSHING  
BUSHING  
SCREW (2 required)  
NUT (2 required)  
FITTING  
PIPE TEE  
PIPE NIPPLE  
HOSE  
EMBLEM  
10 06190A001  
11 25800A500  
12 10649A120  
13 11933A002  
T.O.E. NIPPLE  
TANK  
NOZZLE  
VENTURI TUBE  
FITTING  
TUBE  
SHIM (2 required)  
Water Ace Pump Co. • 1101 Myers Parkway • Ashland, OH 44805  
7/95  
23833A343  
Download from Www.Somanuals.com. All Manuals Search And Download.  
REVISION TO PARTS LIST  
If a 1" x 1" regulator is used, the following parts will be  
different than the parts list found in the jet tank system  
installation manual.  
If a 3/4" x 3/4" regulator is used, follow the replacement parts  
list found in the jet tank system installation manual.  
Ref.  
No.  
Replaced by  
Description  
Part Number  
Part Number  
Description  
3/4" Regulator  
1" Regulator  
3
25443A000  
05762A055  
05004A016  
05004A087  
05916A191  
25443A001  
05762A009  
05004A035  
3/4" x 1" Elbow  
1" Elbow  
4
3/4" x 1/4" Reducer Bushing  
3/4" x 1" Reducer Bushing  
3/4" x 3" Nipple  
1" x 1/4" Reducer Bushing  
Not Required  
5
6
1" x 3-1/2" Nipple  
1/8"" Barbed Fitting  
8
05427A250  
23188A001  
1/4" Barbed Fitting  
21 23188A002  
Retain these instructions for future reference.  
Water Ace Pump Co. 1101 Myers Parkway Ashland, OH 44805  
23833A343  
7/95  
Download from Www.Somanuals.com. All Manuals Search And Download.  

321 Studiosr CX3800 User Manual
Acroprint Modem RS 232 User Manual
AEG Vacuum Cleaner EL4040A User Manual
Alpine Car Stereo System VPA B222 User Manual
Alvin Mobility Aid CH445 User Manual
Amana Furnace ACV9 User Manual
Amana Range AGR5844VD User Manual
Bakers Pride Oven Fryer FKM User Manual
Bakers Pride Oven Oven P18S User Manual
BB Electronics Network Card EIR203 ST User Manual