| INSTALLATION MANUAL   JET TANK SYSTEM   EASTERN   STANDARD   TIME   CONSUMER HOT-LINE: 1-800-942-3343 • MONDAY - FRIDAY • 7 AM to 5 PM   JET TANK   ® R SYSTEM   pump only   with 7-gallon   diaphragm   pressure   tank   MODEL R-30-T7   1/3 Horse Power   Convertible Pump   WARRANTY   PRODUCT DEFECTS   COVERED TWELVE   MONTHS FROM   DATE OF PURCHASE   OR EIGHTEEN   MONTHS FROM   DATE OF MANUFAC-   TURE, WHICHEVER   COMES FIRST. RE-   CEIPT AND PROD-   UCT DATE CODE   REQUIRED FOR   WARRANTY CLAIM.   WATER ACE PUMP COMPANY • ASHLAND, OHIO 44805-1969   23833A343   Download from Www.Somanuals.com. All Manuals Search And Download.   FINDING THE DEPTH OF YOUR WELL   IMPORTANT SELECT   CORRECT VOLTAGE   The jet tank system installs differently depending   on the depth of your well. Tie a small but heavy   weight to the end of a piece of string (be sure there is   enough string; some wells are very deep). Lower the   weight into the well until it reaches the bottom. Take up   the slack and mark the string at ground level. Pull the   weight out of the well and measure from the bottom of   the weight to the ground level mark. This is the depth   of your well. Subtract five feet from the depth of your   well. This number should not exceed the maximum   rated depth for your pump. If it does, it will greatly   hinder or prevent the proper operation of the pump.   GRD   VOLTAGE SELECTOR   AT REAR OF MOTOR   (USE NEEDLE   UNGROUNDED   LINE   NOSE PLIERS)   230V   115V   PULL SELECTOR -   ROTATE - REINSERT   L1   L2   HIGH   LOW   VOLTAGE VOLTAGE   230   VOLTAGE   SELECTOR   TERMINAL BOARD   115   115V OR 230V OPERATION   USE COPPER CONDUCTORS ONLY   Your pump is equipped with one of two types of dual   voltage motors. Follow the instructions to wire the   motor for the proper voltage. The voltage of the pump   must match the voltage of the power supply.   WIRE SELECTION GUIDE   WIRING YOUR PUMP   Remove the cover from the pressure switch. Connect   the bare copper ground to the ground screw in the   pressure switch. Connect the power supply to the   terminals marked "Line" in the diagram below.   NAME   VOLTAGE PLATE   AMPS   MAX. WIRE LENGTH USING AWG SIZE   #14   #8   #12   #10   115   230   10.6   5.3   118   189   296   464   475   756   1184   1857   LINE   FUSE AND CIRCUIT   BREAKER SIZE GUIDE   MOTOR   LOW PEAK - CART. TYPE   FUSETRON - CART. TYPE   FUSTAT - PLUG TYPE*   STANDARD LINE   PLUG FUSE*   CIRCUIT BREAKER   MOTOR   LINE   115V   230V   115V   230V   115V   230V   20   10   12   6-1/4   20   15   GROUND   *For circuits not over 150 volts to ground.   23833A343   3 Download from Www.Somanuals.com. All Manuals Search And Download.   DRAINING FOR SERVICING OR FOR WINTER   PIPING   The pump should be drained before it is disconnected   for servicing or if it is in danger of freezing. To drain:   • Remove drain plug from bottom of pump case.   • Remove discharge tee to vent the pump.   Plastic PVC pipe is shown in the illustrations, but   galvanized steel pipe may be used if desired. All piping   must be clean and free of all foreign matter to prevent   clogging. ALL JOINTS AND CONNECTIONS IN THE   WELL ASSEMBLY MUST BE AIRTIGHT. Even a pin-   hole leak will prevent the proper operation of the pump   (this is the most common problem). Use thread com-   pound on all threaded joints unless specified otherwise.   • Drain all piping to a point 3 feet below ground level.   SHALLOW WELL PUMP INSTALLATION (4" DIAMETER CASED WELL)   For wells 25 feet or less in depth, the ejector may be   attached to the front of the tank-mounted jet pump. For   lower depths, the ejector must be placed down inside   the well (see DEEP WELL PUMP INSTALLATION). All   materials with part numbers are quality Water Ace parts.   • One can PVC cement (read instructions carefully)   • One can thread compound (read instructions carefully)   • Two male 1-1/4" PVC adapters   • Enough rigid 1-1/4" PVC pipe and couplings to reach   from bottom of well to pump.   • One 4" well seal #RWS4-1012 with vent plug   • One 1-1/4" PVC elbow   General Materials   • One Jet Tank System #R-30-T7. Includes: 1/3 HP   jet pump mounted on a 7-gallon diaphragm pressure   tank, pressure gauge, and twin ejector with gasket,   bolts, venturi tubes, and foot valve.   Tools Needed for all pump installations   Pipe wrench, pipe clamp, crescent wrench, slot screw-   driver, 24-tooth hacksaw, knife or round file.   REMINDER: ALL JOINTS AND CONNECTIONS MUST BE AIRTIGHT. A SINGLE PIN-   HOLE LEAK WILL PREVENT THE PROPER OPERATION OF THE PUMP. USE THREAD   COMPOUND ON ALL THREADED CONNECTIONS UNLESS SPECIFIED OTHERWISE.   S3TEP Cement as many coup-   S1TEP Thread 1-1/4" male PVC   lings and sections of   rigid PVC pipe as it   adapter into foot valve.   Hand tighten, then tighten   1/4 turn with crescent   wrench.   1-1/4"   MALE PVC   ADAPTER   takes to equal the depth   of your well minus five   feet, then firmly clamp   the assembly with a   pipe clamp to prevent   assembly from sliding   down into the well.   FOOT   VALVE   Subtract five feet from the   depth of your well (See   page 3 "Finding the Depth   of Your Well"). This is the   S2TEP   PVC   PIPE   SECTION   total length of rigid PVC pipe and   couplings to cement onto the 1-1/4"   male PVC adapter. Cement one   section of rigid PVC pipe to the PVC   adapter which is connected to the   foot valve, then lower the whole   assembly into the well, foot valve   first. Firmly clamp the end of the   rigid PVC pipe with a pipe clamp to   prevent the assembly from sliding   down into the well.   1-1/4"   MALE PVC   ADAPTER   FOOT   VALVE   23833A343   4 Download from Www.Somanuals.com. All Manuals Search And Download.   STEP 9   Remove pipe clamp and   slide Well Seal #RWS4-12   over PVC pipe and onto well   casing. Position assembly   maximum water flow is obtained without   pressure dropping to zero. If pressure falls   completely, retighten adjustment screw and   read-just. Steady pressure must not be less   S4TEP   CONT'D   APPROX.   12" OF   PVC PIPE   PROTRUDING   FROM WELL   SEAL   than 24 lbs. for the R520. If no pressure shows:   Stop motor, remove pressure gauge plug from pressure   regulator, add more water, and try again.   so twelve inches of PVC pipe pro-   trude from well seal. Alternately turn   bolts on well seal counterclockwise   until rubber gaskets are tight against   well casing and PVC pipe.   WELL   SEAL   #RWS4-12   Thread pressure   gauge plug back   STEP   into discharge   tee. Thread   pressure gauge into pres-   sure gauge plug. Make   sure all connections are   tightly sealed. Place a   large basin beneath dia-   phragm tank outlet. Start   motor. If pump is off-set   from well 4 feet or more, it   may take a few minutes   for pump to prime. Failure to prime in 5 minutes:   Stop motor, remove pressure gauge plug from dis-   charge tee, add more water, try again. Allow pump to   run long enough to clear the well of sand or dirt and to   insure well will not run dry. Stop motor.   Cement 1-1/4" PVC elbow   onto PVC pipe protruding   from well seal. If desired,   STEP   10   1-1/4"   PVC   ELBOW   5 some length may be cut off   of PVC pipe before cementing   elbow. Smooth inside of any cut   PVC pipe with file or knife.   TOP OF   PVC PIPE   PROTRUDING   FROM WELL   SEAL   Open ejector   pack included   VENTURI   TUBE   S6TEP   BOLTS   GASKET   EJECTOR   with your jet sys-   tem. The ejector   has two holes in its top.   Thread the venturi tube   (part #25881A281 stamped on the side) into larger hole   until snug. Put gasket over venturi tube so openings in   gasket line up with openings in ejector.   Connect the 1" tank outlet to the service line.   Total installation should look like the drawing   below.   STEP   Secure ejector and   gasket to front of tank-   mounted pump with   bolts provided. Thread   a 1-1/14" male PVC   adapter into front of   ejector.   S7TEP   11   EJECTOR   MALE PVC   ADAPTER   Cement as much PVC pipe and couplings   needed to connect PVC elbow to male PVC   adapter in front of ejector. The diaphragm   pressure tank is preset to 30 PSI. Reset   pressure to 18 PSI using a tire gauge. This is vital to   proper operation of the system.   S8TEP   COMPLETE   SHALLOW WELL   INSTALLATION   Place a large bucket   beneath the pressure   regulator outlet. Start   STEP   PRESSURE   PRESSURE   REGULATOR   GAUGE   ADJUSTMENT   9 motor. Turn regulator   adjustment screw down tight.   If pump is properly primed a   high pressure will immediately   show on the pressure gauge.   With pump operating at high   pressure, slowly unscrew reg-   ulator adjustment screw until   23833A343   5 Download from Www.Somanuals.com. All Manuals Search And Download.   DEEP WELL PUMP INSTALLATION (4" DIAMETER CASED WELL)   • One 1-1/4" close nipple   • One 1" x 4" nipple   • One 1-1/4" x 5" nipple   • Two 1" female PVC adapters   • One 1" male PVC adapter   • Two 1-1/4" male PVC adapters   • Enough rigid 1-1/4" PVC pipe and couplings to reach   from bottom of well to pump (delivery pipe)   • Enough rigid 1" PVC pipe and couplings to reach   from bottom of well to pump (pressure pipe))   • One well seal #RWS4-1012   For wells over 25, but not exceeding 60 feet in depth,   the twin ejector must be installed down inside the well   rather than attached to the front of the pump. Materials   with part numbers are quality Water Ace parts.   General Materials   • One Jet Tank System #R-30-T7. Includes: 1/3 HP   jet pump mounted on a 7-gallon diaphragm pressure   tank, pressure gauge, and twin ejector with   gasket, bolts, venturi tubes, and foot valve.   • One can PVC cement (read instructions carefully)   • One can thread compound (read instructions carefully)   • One 1-1/4" PVC elbow   • One 1" PVC elbow   REMINDER: ALL JOINTS AND CONNECTIONS MUST BE AIRTIGHT. A SINGLE PIN-   HOLE LEAK WILL PREVENT THE PROPER OPERATION OF THE PUMP. USE THREAD   COMPOUND ON ALL THREADED CONNECTIONS UNLESS SPECIFIED OTHERWISE.   Lower the assembly into   S1TEP Thread 1-1/4" close nipple   S5TEP   into foot valve. Thread the   the well, foot valve first.   Use a pipe clamp to   prevent assembly for   sliding down into well.   Cement as many   couplings and sections   of rigid PVC pipe on   both sides of ejector as   it takes to equal the   depth of your well minus   five feet, then firmly   clamp assembly with a   pipe clamp to prevent it   from sliding down into   the well.   EJECTOR   other end of 1-1/4" close   nipple into bottom of twin   ejector. Hand tighten, then   tighten 1/4 turn with pipe   wrench.   1-1/4"   CLOSE   NIPPLE   FOOT   VALVE   The ejector has two holes in   the top of it. Thread venturi   tube (part #25881A281   stamped on the side) into   S2TEP   1" X 5"   NIPPLE   larger hole until snug. Thread 1" x   5" nipple into smaller hole. Only   hand tighten venturi tube. Tighten   nipple 1/4 turn with pipe wrench.   VENTURI   TUBE   EJECTOR   Thread a 1-1/4" male PVC   adapter over the venturi   tube and into ejector.   Thread a 1" female PVC   adapter onto 1" x 5" nipple.   Tighten adapters 1/4 turn   with crescent wrench.   S3TEP   1" FEMALE   PVC   ADAPTER   1-1/4" MALE   PVC   ADAPTER   Remove pipe clamp and   slide well seal #RWS4-1012   over PVC pipes and onto   well casing. DO NOT let   S6TEP   12" OF   PVC PIPE   PROTRUD-   ING FROM   WELL   Subtract five feet from the   depth of your well. This is   the total length of PVC pipe   STEP   1"   PVC   PIPE   1-1/4"   PVC   PIPE   SEAL   assembly slide down into well. Posi-   tion assembly so that twelve inches   of PVC pipes protrude from well   seal. Using crescent wrench, turn   bolts on well seal counterclockwise   until rubber gaskets are tight against   the well casing and the PVC pipes.   4 and couplings to cement   onto both the 1-1/4" male and 1"   female PVC adapters. Cement a   section of PVC pipe to each adapter.   WELL SEAL   #RWS4-1212   23833A343   6 Download from Www.Somanuals.com. All Manuals Search And Download.   Cut 1" pipe 2" shorter than   the 1-1/4" pipe. Smooth   rough edges. Cement 1"   and 1-1/4" PVC elbows to   pipes protruding from the   well seal.   STEP   1-1/4" PVC   ELBOW   1" PVC   ELBOW   7 1" PIPE 2"   SHORTER   THAN 1-1/4"   PIPE   Thread 1-1/4" male PVC   adapter into top hole in front   of tank-mounted pump.   Thread 1" x 4" nipple into   bottom hole in front of pump.   STEP   1 1/4" MALE   PVC   ADAPTER   8 1" x 4"   NIPPLE   Thread the 1" female PVC   adapter onto the 1" x 4"   nipple.   STEP   1 1/4"   FEMALE   PVC   COMPLETE   DEEP WELL   INSTALLATION   9 ADAPTER   STEP   10   1 1/4" PVC PIPE   Cement as   many sec-   tions and   1" PVC PIPE   CAUTION: If you change pressure switch settings,   set the cut-off pressure low enough to shut off the   pump. The recommended pressure is 2 PSI below   your pump cut-off pressure. Example: if a 20-40 PSI   pressure switch is being used, tank pressure should   be 18 PSI. If a valve shuts off and the cut-off setting   is too high, the pump will run continuously without   water flow causing overheating and serious damage.   couplings of   rigid 1" and   1-1/4" PVC pipe needed to connect the 1" female PVC   adapter and the 1-1/4" male PVC adapter to the 1" and   1-1/4" PVC elbows. The diaphragm pressure tank is   factory preset to 30 PSI. Reset the pressure to 18   PSI using a tire gauge. This is vital to the proper   operation of the system. Remove pressure gauge plug.   Place a large bucket   beneath the pressure   regulator outlet. Start   motor. Turn regulator   STEP   REGULATOR   ADJUSTMENT   SCREW   11   adjustment screw down tight.   If pump is properly primed a   high pressure will immediately   show on the pressure gauge.   With pump operating at high   pressure, slowly unscrew reg-   ulator adjustment screw until   maximum water flow is obtain-   ed without pressure dropping to zero. If pressure falls   completely, retighten adjustment screw and re-adjust.   Steady pressure must not be less than 24 lbs. for the   R520 and 32 lbs. for the R100. If no pressure shows:   Stop motor, remove pressure gauge plug from pressure   regulator, add more water, and try again. Complete   installation should look like the drawing to the right.   23833A343   7 Download from Www.Somanuals.com. All Manuals Search And Download.   TROUBLESHOOTING CHECKLIST   (CAUTION: SHUT OFF POWER TO PUMP)   PROBLEM   POSSIBLE CAUSES   • Not enough water. Stop motor, remove pressure gauge plug, and fill case with water.   • Pump wired incorrectly.   • Plugged venturi tube or nozzle.   Pump will not prime   • Foot valve is sitting in sand or mud, or is stuck shut, or leaks.   • Low well water level. In deep wells, the ejector as well as the foot valve must be below   water level.   • Leaks. Check all connections for airtightness.   • Low well water level. Use a water-level tester while pump is operating.   • Plugged venturi tube, nozzle, or impeller parts.   Pump delivers water   for a period of time,   then stops pumping   • Plugged venturi or nozzle.   • Faulty pressure gauge resulting in false readings.   • In deep wells, the operating pressure may be too high.   • Low well water level. Use a water-level tester while pump is operating.   • Over-submergence of ejector. In deep wells, if ejector is more than 10 feet below   pumping level, pumping capacity is reduced.   Pump does not de-   liver rated capacity   • In deep wells, the ejector may have improper size and depth setting.   • Motor voltage does not match power supply voltage. See pages 2 and 3.   • Improper wire size. See Wire Size Guide on page 3.   • Impeller is rubbing against pump case.   Motor overheats and   shuts off (overload)   • Impeller neck is worn.   • Defective pressure switch.   • The tube connecting the two brass fittings may be clogged.   • Tank precharge pressure too high. Tank precharge pressure must be 1-2 pounds less   than switch turn-on setting.   Pump delivers water   but will not shut off   • In deep wells, the water level may be going below limit of ejector. Use water-level   tester while pump is operating.   Pressure switch   turns on and off   every few seconds   • Galvanized storage tank is waterlogged.   • Leaky foot valve.   • Too much tank pressure.   Motor fails or does   not operate properly   • If within Warranty, return pump/motor unit to place of purchase (with proof of purchase)   for exchange.   LIMITED WARRANTY   WATER ACE PUMP CO. will repair or replace for the original user any portion of a new   Water Ace product which proves defective due to materials or workmanship of WATER ACE   PUMP CO. Contact the nearest authorized WATER ACE PUMP CO. dealer for warranty   service. WATER ACE PUMP CO. shall possess the sole right to determine whether to repair   or replace defective equipment, parts or components. THIS WARRANTY DOES NOT   COVER DAMAGE DUE TO LIGHTNING OR OTHER CONDITIONS BEYOND THE   CONTROL OF WATER ACE PUMP CO.   PRODUCT IMPROVEMENTS: WATER ACE PUMP CO. reserves the right to change or   improve its products or any component without obligation to provide such a change or   improvement for units previously sold and/or shipped.   WARRANTY EXCLUSIONS: After the expiration of this warranty period, THERE WILL BE   NO WARRANTIES INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR   FITNESS FOR ANY PARTICULAR PURPOSE ON ANY SPECIFIC WATER ACE PUMP   PRODUCT. Some states do not allow limitations on how long an implied warranty lasts, so   the above limitation may not apply to you. No warranties or representations at any time   made by any representative of WATER ACE PUMP CO. shall vary or expand the provisions   hereof.   PUMPS: Warranted 12 months from date of purchase or 18 months from date of   manufacture, whichever occurs first. Receipt and product date code required for warranty   claim.   LABOR & COSTS: WATER ACE PUMP CO. shall IN NO EVENT be liable for the cost of   field labor or other charges incurred by any customer in removing and/or reaffixing any   WATER ACE PUMP product. part or component.   LIABILITY LIMITATION: IN NO EVENT SHALL WATER ACE PUMP CO. BE LIABLE FOR   CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES RESULTING FROM OR   RELATED IN ANY MANNER TO ANY WATER ACE PUMP PRODUCT OR PARTS. Some   states do not allow the exclusion or limitation of incidental or consequential damages, so the   above limitation may not apply to you. This Warranty gives you specific legal rights. You   may have other rights which vary from state to state. In the absence of suitable proof of   purchase date, the effective date of this warranty will be based upon the date of manufacture   plus 180 days.   THIS WARRANTY WILL NOT APPLY: (a) to defects or malfunctions resulting from failure to   properly install, operate, or maintain the unit in accordance with printed instructions provided;   (b) to failures resulting from abuse, accident, or negligence; (c) to normal maintenance   services and the parts used in connection with such service; (d) to units which are not   installed in accordance with applicable local codes, ordinances, and good trade practices; (e)   if the unit is moved from its original installation location; (f) if unit is used for purposes other   than for what it was designed and manufactured.   Direct all Notices, etc. to: Product Warranty and Return Dept., WATER ACE PUMP CO., 1101   Myers Parkway, Ashland, OH 44805-1969   23833A343   Water Ace Pump Co. • 1101 Myers Parkway • Ashland, Ohio 44805-1969   7/95   Download from Www.Somanuals.com. All Manuals Search And Download.   REPLACEMENT PARTS   1 12   2 3 25   4 16   17   14   24   21   23   15   18   9 13, 19, 20   10   11   16   7 JET TANK SYSTEM   MODEL R-30-T7   22   REF.   NO.   REF.   NO.   PART NUMBER   DESCRIPTION   PART NUMBER   DESCRIPTION   1 2 3 4 5 6 7 8 9 20929D501   05003A000   24349B000   23188A005   05004A015   05004A087   05126A013   05916A171   05920A173   PUMP   14 24859C500   15 19101A019   16 14740A001   17 15760A510   18 19277A001   19 19100A029   20 19109A012   21 23188A002   22 25579A108   23 08728A006   24 25881A281   25 23188A001   EJECTOR BODY   SCREW (2 required)   HOSE CLAMP (2 required)   REGULATOR SWITCH   GASKET   PRESSURE GAUGE   REGULATOR   HOSE ADAPTER   BUSHING   BUSHING   SCREW (2 required)   NUT (2 required)   FITTING   PIPE TEE   PIPE NIPPLE   HOSE   EMBLEM   10 06190A001   11 25800A500   12 10649A120   13 11933A002   T.O.E. NIPPLE   TANK   NOZZLE   VENTURI TUBE   FITTING   TUBE   SHIM (2 required)   Water Ace Pump Co. • 1101 Myers Parkway • Ashland, OH 44805   7/95   23833A343   Download from Www.Somanuals.com. All Manuals Search And Download.   REVISION TO PARTS LIST   If a 1" x 1" regulator is used, the following parts will be   different than the parts list found in the jet tank system   installation manual.   If a 3/4" x 3/4" regulator is used, follow the replacement parts   list found in the jet tank system installation manual.   Ref.   No.   Replaced by   Description   Part Number   Part Number   Description   3/4" Regulator   1" Regulator   3 25443A000   05762A055   05004A016   05004A087   05916A191   25443A001   05762A009   05004A035   — 3/4" x 1" Elbow   1" Elbow   4 3/4" x 1/4" Reducer Bushing   3/4" x 1" Reducer Bushing   3/4" x 3" Nipple   1" x 1/4" Reducer Bushing   Not Required   5 6 1" x 3-1/2" Nipple   1/8"" Barbed Fitting   8 05427A250   23188A001   1/4" Barbed Fitting   21 23188A002   Retain these instructions for future reference.   Water Ace Pump Co. • 1101 Myers Parkway • Ashland, OH 44805   23833A343   7/95   Download from Www.Somanuals.com. All Manuals Search And Download.   |