AMX Switch RDM 3EM User Manual

Installation Sheet  
RDM-3EM and RDM-6EM Energy Management Modules  
The RDM-3EM (FG606-81) and RDM-6EM (FG606-80) are 3 and 6  
Mounting  
points  
channel switching energy management modules. They are designed for use  
with the RDA series of enclosures in an AMX Lighting™ system.  
For more detailed installation and operating instructions, refer to the Radia  
Lighting Control System Instruction Manual, available on-line at  
1
The RDM-3EM and RDM-6EM are designed with the most advanced  
latching energy management relays to support heavy duty commercial  
applications, building automation, and loadside management. Equipped  
with on-board module microprocessors, both support relay control and  
sequencing. Features include:  
Relays  
(1-3)  
2
3
User selectable delays in sequencing mode to minimize inrush current  
and stress on the electrical distribution system.  
Selectable strapping facilitates multiple relays on one Radia control  
channel for large area control.  
Manual on/off override on each relay independent of control system.  
Relays retain their state during power and control system outages.  
Visual Status Indicators on each relay.  
Latching relays do not consume any control current, except when they  
change state, eliminating the need for additional Radia power supplies.  
Mounting  
points  
Control  
Port  
Sequencing  
Delay Jumpers  
(JP1 and JP2)  
Strapping  
Jumpers  
(JP3 - JP4)  
1
2
Relays  
(1-6)  
3
Mounting points  
4
5
FIG. 2 RDM-3EM  
RDM-3EM and RDM-6EM UL and C-Ul Ratings  
General purpose: 120, 240, 277, and 347* VAC, 20 A  
UL/CUL916 Energy Management Systems.  
UL/CUL508 Industrial Control Systems.  
6
Suggested Switched Loads  
Incandescent  
Fluorescent  
Transformer  
Low voltage  
General purpose  
Control  
Port  
Strapping  
Jumpers  
(JP3 - JP7)  
Sequencing  
Delay Jumpers  
(JP1 and JP2)  
Caution: Pre-Installation Notes  
All Class 1 wiring must be connected to proper terminals.  
All control wiring must be connected to proper terminals.  
Disconnect power while installing or connecting the unit.  
Keep top and bottom air vents clear at all times.  
Test loads for shorts before connecting.  
Use low voltage wires with a 300 volt rating or greater.  
Use field installed copper conductors.  
All electrical ratings are for continuous duty.  
For indoor use only.  
Mounting points  
FIG. 1 RDM-6EM  
Specifications  
Dimensions (HW): 10.00" x 2.75" (25.40 cm x 6.99 cm)  
Non-phase dependant  
Use wires rated at 75°C (167°F)  
Torque terminals to 4.4 in lbs.  
Wire size: 26 AWG to 10 AWG  
Wire stripping length: 0.28" (7 mm)  
Weight: 15 oz. (RDM-3EM) and 1.5 lbs. (RDM-6EM)  
Included Accessories  
4 mounting screws  
Control wiring harness  
*Agency approval pending  
Download from Www.Somanuals.com. All Manuals Search And Download.  

ADTRAN Network Card QDFR Unit User Manual
Agilent Technologies Network Router 8714 User Manual
Agilent Technologies Stereo System 8731A User Manual
Aiwa Radio FR CD1500 User Manual
AOC Flat Panel Television L19W981 User Manual
ATI Technologies Stereo Amplifier ATP 8500 User Manual
Axis Communications TV DVD Combo AXIS P7701 User Manual
Bakers Pride Oven Microwave Oven PICA70 32 AED User Manual
BC Speakers Speaker System 6 PE 13 User Manual
Behringer Car Amplifier BX1800 User Manual