Installation Guide
IRX-PP38 NetLinx Plasma-Proof IR Sensor
IRX-PP38 IR Sensor Overview
IRX-PP38 #1
This connection may
The IRX-PP38 IR sensor is designed to provide optimum functionality for IR
reception and transfer to high-end devices such as plasma televisions which
sometimes can have issues with other receivers. The IRX-PP38 is compatible
with AMX’s newest NI-700 and NI-900 NetLinx Master Controllers.
vary among different
+12 VDC
compatible AMX devices
GND
IRX-PP38 Specifications
SIG (signal)
Current Draw:
• 10 mA @ 12VDC
Dimensions
(HWD):
Top view
• 0.56" x 3.88" x 1.06" (1.43 cm x 9.84 cm x 2.70 cm)
Features:
• Relies on both optical and electronic filtering to reject
interference from fluorescent lamps and plasma displays.
• Supports an AMX IR frequency of 38 KHz.
IRX-PP38 #2
To the Integrated
Controller’s rear
Mounting:
• Main unit can either be hidden behind other electronics or
secured to a surface near the target device.
• Maximum wire distance to an NI700/900: 200 feet (60.96
meters)
IR RX connector
+12 VDC
GND
IN
GND
AUX
SIG (signal)
IR Sensor
Components:
• IR Feedback LED (blue). LED illuminates when it receives an IR
signal.
• 3-pin mini-Phoenix connector. Wires the IRX-PP38 to the IR
receive port on compatible AMX devices.
PWR
Top view
Top view
• Terminal IR sensor. This sensor adheres to any object within the
line of sight of your remote and enables you to receive control
signals from either an IR Emitter or a hand-held remote control.
• Two screw openings. These openings (located at opposite ends
of the main IR sensor) are used to secure the unit. This portion
of the IRX-PP38 is kept out of sight whereas the terminal IR
sensor adheres to the IR window.
FIG. 2 Sample wiring diagram between NI Controller and multiple IRX sensors
Installation Overview
Note: Never pre-tin wires for compression-type connections.
1.
2.
Strip 0.25 inch (6.35 mm) of insulation off all wires.
Insert each wire into the appropriate opening on the IRX-PP38 connector
according to the wiring diagrams and connector types described in FIG. 2.
Note: Always match the wiring on each end of these connections. If you
are using a red insulated wire to supply power on one connector, make
sure you thread this same wire into the PWR connector at the other end.
Insert each wire into the appropriate opening on the NI’s rear IR RX
connector, according to the wiring diagrams and connector types described
Included
Accessories:
• Adhesive foam (pre-installed onto the terminal IR sensor)
• IRX-PP38 Installation Guide (93-0460)
• Two black metal screws (#2 x 3/8”)
IRX-PP38 Plasma-Proof Components
3.
4.
The terminal IR sensor is wired to the main unit via a 34-inch long (2.83 feet)
cable. The main unit provides both an on-board blue LED (to confirm IR
reception) and a 3-pin mini-Phoenix connection used to wire the sensor to the IR
RX (sensor) port on the back of a compatible AMX device (such as the
NI-700/900 Controllers).
Tighten the screws to secure the wires into their respective connectors.
Note: Do not tighten the screws excessively. Doing so may strip the
threads and damage the connector.
5.
6.
Remove the cover off the adhesive foam on the IR sensor.
Adhere the adhesive flat side of the terminal plasma-proof IR sensor to any
object within the line of sight of your remote. Make sure the raised oval side
of the terminal IR sensor (opaque) is facing outwards and can receive the
IR signal from the remote (such as a Mio R-1).
IRX-PP38
Plasma TV
Wired to
NI-700/900
IR feedback LED (blue)
Terminal
Plasma-proof
IR sensor
FIG. 1 IRX-PP38 connector
Wiring the IRX-PP38 IR Sensor
NI Controller
(with IRX port)
The maximum wiring distance between the IRX and a target NI Controller (such
as the NI-700 and NI-900) is 200 feet (60.96 meters). FIG. 2 displays a sample
wiring diagram which shows how you can wire a single Controller for
communication to two separate IRX IR sensors.
Mio R-1
FIG. 3 Equipment wiring overview
You can use the IRX-PP38 in any installation where a previous AMX IRX device
was used. For illustration purposes, the NI-900 is used in this document’s wiring
diagrams.
Note: The IRX- PP38 uses the IR input port on an NI-700/900 controller (one
IRX-PP38 per NI-700/900).
For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).
93-0460
REV: B
03/08
©2008 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX.
AMX reserves the right to alter specifications without notice at any time.
Download from Www.Somanuals.com. All Manuals Search And Download.