P/N 1200506L1
NetVanta 1024 PWR Power over Ethernet Midspan
Quick Start Guide
DATA & POWER
DATA
NetVanta 1024
Power over Ethernet
POWER OVER ETHERNET
ACCESS THE CLI
The NetVanta 1024 PWR Power over Ethernet Midspan products provide a cost effective way to
offer power over Gigabit Ethernet to existing nonpowered switches. These units deliver 15.4 watts
per port (up to 370 watts), supporting power over Ethernet. This supplies 48 VDC to powered
devices (e.g., IP phones, wireless access points, IP cameras, etc.) over existing CAT5 cabling.
These NetVanta products are fully compliant with IEEE 802.3af Power over Ethernet (PoE)
standards, and they support legacy (pre-standard) PoE.
Access the AOS CLI via the CONSOLE port or a Telnet session. To establish a connection to the
NetVanta unit CONSOLE port, you need the following items:
•
•
VT100 terminal or PC (with VT100 terminal emulation software)
Straight-through serial cable with a DB-9 (male) connector on one end and the appropriate
interface for your terminal or PC communication port on the other end
1. Connect the DB-9 (male) connector of your serial cable to the CONSOLE port on the rear
By default, the midspan products detect and provide power to nonpowered switches.
panel of the unit.
2. Connect the other end of the serial cable to the terminal or PC.
GETTING STARTED
Two configuration methods are available for your NetVanta unit:
3. Insert the connector of the provided power cord into the power interface on the rear panel of
the unit, and plug the cord into a standard electrical outlet.
•
•
Web-based GUI
4. Once the unit is powered up, open a VT100 terminal session using the following settings:
AOS Command Line Interface (CLI)
9600 baud, 8 data bits, no parity bits, and 1 stop bit. Press <Enter> to activate the AOS CLI.
The GUI lets you configure the main unit settings and provides online guidance and explanations for
each setting. However, using the AOS CLI may be necessary for more advanced configurations.
5. Enter enable at the > prompt.
6. Enter the enable password when prompted. The default password is password.
ACCESS THE GUI
You can access the web-based GUI from any web browser on your network by following these
steps:
CONFIGURE THE UNIT’S IP ADDRESS
The following steps create an IP address and subnet mask for the ETH 0/0 port. If you are not sure
what IP address to assign, please contact your network administrator.
1. Connect the unit to your PC using the ETH 0/0 port on the rear of the unit.
1. At the # prompt, enter config terminal.
2. Set your PC to a fixed IP address of 10.10.10.2. If you cannot change the PC’s IP address, you
will need to change the unit’s IP address using the CLI. (Refer to the next two sections for
instructions.)
2. At the (config)# prompt, enter interface eth 0/0 to access the configuration parameters for
the Ethernet interface.
3. Enter ip address 10.26.12.12 255.255.255.0 to assign an IP address to the Ethernet
3. Enter the unit’s IP address in your browser address line. The default IP address is 10.10.10.1.
interface using a 24-bit subnet mask.
4. You will then be prompted for the username and password (the default settings are admin and
password).
4. Enter no shutdown to activate the interface to pass data.
5. Enter exit to return to the Global Configuration mode.
5. The initial GUI screen appears.
Depending on your configuration, you may need to set a default gateway
as well using the (config)#ip default gateway command. If IP routing is
enabled on the unit, do NOT set a default gateway.
Quick Start Guide, 61200506L1-13A, March 2006
Technical Support 1-888-4ADTRAN (1-888-423-8726)
Download from Www.Somanuals.com. All Manuals Search And Download.