STEP ONE - REGISTERING YOUR BEACON  
1.  
Why is registration important?  
As the owner of this 406 MHz beacon, it is mandatory that you register  
it with the EPIRB national authority of your country: It is the law.  
Please note that all 406 MHz beacons are required to have their registration  
updated every two years by the owner.  
Your unique ID code  
programmed inside each EPIRB is  
YOUR RESCUE WILL  
BE DELAYED IF YOUR  
BEACON ISN’T PROPERLY  
REGISTERED!  
transmitted to Search and Rescue  
(SAR). SAR forces use this code to pull  
up your registration to find out valuable  
information about who needs help.  
HOW REGISTRATION WORKS:  
All 406 MHz beacons transmit a Unique Identifier Number (UIN) when  
activated. This UIN is programmed into the beacon based on the country in  
which the beacon is registered, thus authorities are able to determine which  
country’s database will have your registration information. SAR forces will  
have information as to who you are as the owner of the beacon, the name  
and type of vessel that you have, your homeport, and who to contact that  
might know of your current situation - but only if your beacon has been  
properly registered. Valuable search and rescue resources are wasted  
every year responding to false alarms, and registering your beacon helps to  
resolve false alarms quickly.  
Y1-03-0250DRowenvl.oaBd from Www.Somanuals.com. All Manuals Search And Download.  
3
 
2.  
What country should I register in?  
Register your beacon with the EPIRB national authority of the country for  
which the beacon was programmed, typically the country where purchased,  
regardless of where you do your boating.  
The beacon must be reprogrammed if you, as the owner, move or the  
vessel sails under the flag of a different country than the one for which the  
beacon was previously programmed. To verify the country for which a  
beacon is programmed, see the label with the UIN (Unique Identification  
Number) on the back of the unit. Units that do not have a country specified  
on the UIN label are programmed for the United States.  
3.  
How do I register?  
Registration in the United States  
The national authority that accepts registrations in the United States is the  
National Oceanic and Atmospheric Administration (NOAA).  
Here are three ways to register:  
1. The fastest and easiest way to register is online at  
2. Faxing a registration is also acceptable. Fax the registration form to the fax  
number on the top of the registration form.  
NOTE: Do not confuse the registration form with the ACR Electronics  
warranty card.  
3. If online or fax registration is not available, mail the registration form with the  
pre-addressed, postage paid envelope to:  
NOAA SARSAT Beacon Registration  
NSOF, E/SP3  
4231 Suitland Road  
Suitland, MD 20746  
All registration forms will be entered in the 406 MHz beacon registration  
database within 48 hours of receipt. The information you provide on the  
registration form is used for rescue purposes only.  
A confirmation letter, a copy of the actual registration and a proof-of-  
registration decal will be mailed to you within two weeks. When you receive  
these documents, please check the information carefully with the  
existing label on the unit, and then affix the decal to your beacon in the  
area marked “BEACON DECAL HERE.” If you do not receive confirmation  
back from NOAA in the expected timeframe, call toll free (888) 212-7283 for  
assistance.  
Y1-03-0250DRowenvl.oaBd from Www.Somanuals.com. All Manuals Search And Download.  
4
Registration outside of the United States  
In countries other than the United States, 406 MHz beacons are registered  
with that country’s national authority at the time of purchase. The sales  
agent should have assisted you in filling out the forms and sending them to  
the country’s national authority. Alternatively, many countries allow online  
registration in the International 406 MHz Beacon Registration Database  
To verify that the unit is properly programmed for your country, view the UIN  
label on the back of the unit. In the event that the beacon is not programmed  
for your country, the sales agent (if properly equipped) can reprogram the  
unit for the correct country.  
4.  
Do I need a radio license?  
In the United States, you may or may not need to obtain or update a radio  
station license. Check the FCC’s website at  
call toll-free (888) 225-5322 (CALLFCC) for the latest information.  
Outside of the United States, contact your local authority for the  
requirements.  
Y1-03-0250DRowenvl.oaBd from Www.Somanuals.com. All Manuals Search And Download.  
5
STEP TWO - HOW THE BEACON WORKS  
1.  
How your beacon brings help  
406 MHz beacons are a type of portable emergency equipment that  
transmits a distress signal to search and rescue (SAR) organizations. The  
purpose of these beacons is to aid SAR teams in tracking and locating ships  
or individuals in jeopardy as rapidly as possible.  
The 406 MHz frequency is a worldwide dedicated emergency frequency that  
is detected by a special system of satellites called the Cospas-Sarsat  
system. This satellite system was established by, and continues to be  
supported by, its primary benefactors - the USA, Russia, Canada and  
France. The Cospas-Sarsat system has saved over 23,500 lives - and  
counting - since its inception. See Appendix G or the Cospas-Sarsat website  
for more information about the system at www.cospas-sarsat.org.  
When a 406 MHz beacon is activated, the digital distress message is sent to  
Cospas-Sarsat satellites and, in turn, the distress message is relayed to  
SAR. The distress message contains important information about the  
beacon and its owner. Additional information about the beacon is accessed  
by SAR from the beacon registration database. At the same time the 406  
MHz signal is activated, a 121.5 MHz signal is turned on. The 121.5 MHz  
signal is used by SAR to home in on the beacon as they approach it.  
The 406 MHz signal is detected by multiple satellites and from that  
information the location of the beacon can be calculated. This data alone is  
sufficient for SAR to find persons or ships in distress in a reasonable  
timeframe. However, as a further enhancement, some beacons have a GPS  
engine onboard. This feature allows the beacon to acquire current location  
coordinates from an internal GPS receiver or download coordinates from an  
external GPS receiver. The coordinates are added to the ID of the unit,  
which is transmitted with the 406 signal. This enables the SAR authorities to  
locate the beacon to an accuracy of 110 yards (100 m).  
Y1-03-0250DRowenvl.oaBd from Www.Somanuals.com. All Manuals Search And Download.  
6
 
2.  
Anatomy of your beacon  
NOTE: When unpacking your beacon, it is recommended that you save the  
original packaging for re-use when shipping the beacon for battery  
replacement in the future.  
// Activation switch with Witness Tab  
The activation switch embodies a special, patented method of activating a  
beacon. Refer to a subsequent section of this manual for how to activate the  
beacon.  
// Optional External GPS interface  
The external GPS Interface serves as the connection to the ship’s GPS  
system. Use of this feature requires the purchase of an Optical GPS  
interface Cable.  
Y1-03-0250DRowenvl.oaBd from Www.Somanuals.com. All Manuals Search And Download.  
7
 
Strobes  
Top View  
Antenna  
Optional GPS  
Interface  
Green  
LED  
Activation/  
Test Switch  
Red  
LED  
Switch Positions  
OFF/READY  
Position  
TEST  
Position  
ON/TRANSMITTING  
Position  
Y1-03-0250DRowenvl.oaBd from Www.Somanuals.com. All Manuals Search And Download.  
8
Category 1 SeaShelter3 Bracket  
Ejector  
Spring  
Spring  
Release  
Knob  
HydroFix™  
Hydrostatic  
Release Unit  
(HRU)  
Optional GPS  
Interface  
Cable  
Antenna  
Hook  
Front cover  
hook (detent)  
Category 2 – QuickDraw™ Bracket  
Antenna Hook  
Water Sensor  
Deactivation Magnet  
Release Latch  
Y1-03-0250DRowenvl.oaBd from Www.Somanuals.com. All Manuals Search And Download.  
9
3.  
Activating your beacon  
WARNING: This transmitter is authorized for use only during  
situations of grave and imminent danger. Deliberate misuse may incur a  
severe penalty.  
Overview  
Category I beacons are designed to be automatically deployed and  
activated in the event of a sinking vessel. The beacon may also be hand  
held on the deck of vessels, or floated in water and attached to a raft or life  
vest with the lanyard provided.  
Category II beacons are designed to be manually deployed from the  
bracket.  
Two conditions must be met for a Category II beacon to automatically  
activate:  
// It must be out of its bracket  
// It must be wet  
NOTE: Either condition by itself will not automatically activate the beacon.  
Category I and II beacons can always be manually activated in or out of  
their bracket.  
The beacon and bracket are designed to allow the user to perform periodic  
testing while the beacon is in its bracket.  
Y1-03-0250DRowenvl.oaBd from Www.Somanuals.com. All Manuals Search And Download.  
10  
Category I beacons-Automatic deployment and activation  
If the vessel sinks, the HydroFix™ HRU frees the beacon from the bracket,  
allowing it to float to the surface. Built-in sensors detect that the beacon is  
no longer in its bracket and when continuity is created by water between  
two of the top cap screws, an activation circuit is completed.  
NOTE: Transmission of the 121.5 MHz and 406 MHz signals will not occur  
until 100 seconds after activation.  
Ejector Spring launches EPIRB  
from the bracket allowing it to  
float freely to the water surface.  
HRU releases the rod  
separating the front and  
back cover of bracket at a  
depth between 4-13 feet.  
Y1-03-0250DRowenvl.oaBd from Www.Somanuals.com. All Manuals Search And Download.  
11  
Category I and II Beacons-Manual deployment and activation  
Both Category I and II beacons can be manually deployed by removing the  
beacon from the bracket.  
Once removed, the beacon can be activated by placing it in water OR by  
lifting the Activation Switch to a vertical position, sliding it toward the  
antenna and pushing down to the opposite side of the beacon. Activating  
the beacon in this manner breaks off the Activation Witness Tab and allows  
the switch to properly seat, showing the “ ▌ “ symbol (ON).  
A Category I or II beacon MANUALLY activates with the following sequence:  
1.) Remove the beacon from its bracket  
2.) Activation method one: Place beacon in water  
3.) Activation method two:  
// Lift the switch to a vertical position  
// Slide the switch toward the antenna  
// Push the switch down to the opposite side of the beacon (see  
illustration below)  
Category I and II Beacons-Manual Activation Without Deployment  
The beacon can be manually activated while still in its bracket by placing the  
Activation Switch in the ON position. Activation by this method overrides all  
sensors and turns the beacon “ON.”  
Push the main switch up  
90 degrees, slide toward  
antenna and all the way  
down to activate.  
Witness tab will break  
once placed in the “ON”  
position.  
Y1-03-0250DRowenvl.oaBd from Www.Somanuals.com. All Manuals Search And Download.  
12  
TIPS FOR OPTIMUM DEPLOYMENT OF AN ACTIVATED BEACON:  
When activating and deploying your beacon in an emergency, DO  
NOT:  
// Hold or clutch the beacon or antenna  
// Operate the beacon while hand held, if at all possible  
// Turn the beacon off for any reason, including to save power  
// Activate the beacon if you have any other means of self rescue  
// Operate the beacon inside a life raft or under any other canopy or  
cover  
// Tether the beacon to the bracket or vessel  
When activating and deploying your beacon in an emergency, DO:  
// Follow the steps to activate the beacon as described on the beacon or  
in this manual  
// Give clear view to the sky for best performance  
// Take the EPIRB with you if abandoning ship, provided there is time to  
get it  
// Tether beacon, using the lanyard, to the life raft and let the beacon  
float (if in a life raft)  
// Keep EPIRB upright for best signal transmission, either by floating it,  
resting it or holding it in this position  
// Manually activate the beacon if it has not been automatically activated  
4.  
Turning off the beacon  
If your beacon was manually activated and you wish to deactivate, return  
the thumb switch to the “OFF” position. If automatically activated and you  
wish to deactivate, remove the beacon from the water and dry the unit or  
place the beacon back into the release bracket. The beacon normally takes  
up to 12 seconds to deactivate.  
If deactivation should fail, remove the four screws holding the unit together  
and unplug the battery to disable the unit. Return the beacon to ACR  
Electronics for service.  
Y1-03-0250DRowenvl.oaBd from Www.Somanuals.com. All Manuals Search And Download.  
13  
5.  
False alarms  
To prevent false alarms, it is important to be aware of how your beacon can  
be activated. An ACR 406 MHz EPIRB can be activated by two different  
methods. Whether you have a Category I or Category II, these methods are  
the same.  
// When the beacon is out of its bracket and wet, the unit will start  
transmitting  
// When the switch is moved to the “ON” position, in or out of the  
bracket, the unit will start transmitting  
Precautions to prevent false alarms  
// Do not mount or transport the beacon within 4.6 ft/1.4 m of a  
magnetic source.  
// Do not store the beacon outside of its bracket if it can get wet.  
// Do not mount the EPIRB backwards in its bracket (lanyard roll must  
face in).  
// Do not clean the beacon with a water hose and brush while out of  
its bracket.  
Reporting  
Should there be, for any reason, an inadvertent activation or false alarm, it  
must be reported to the nearest search and rescue authorities. The  
information that should be reported includes:  
// The EPIRB 15-digit Unique Identifier Number (UIN)  
// Time and date  
// Duration and cause of activation  
// Location of beacon at the time of activation  
To report false alarms in the United States, contact any of the following:  
US Region  
Telephone Number  
Atlantic Ocean / Gulf of Mexico  
USCG Atlantic Area Command Center  
(757) 398-6390  
Pacific Ocean Area /  
USCG Area Command Center  
(510) 437-3700  
(800) 323-7233  
USCG HQ Command Center  
To report false alarms outside of the USA, contact the national authority  
where your beacon is registered.  
Y1-03-0250DRowenvl.oaBd from Www.Somanuals.com. All Manuals Search And Download.  
14  
STEP THREE - INSTALLING THE BEACON  
1.  
Marking battery and Hydrostatic Release Unit expiration dates  
NOTE: It is the beacon owner’s responsibility to record the expiration dates  
for both the beacon battery and the HydroFix™ hydrostatic release unit.  
This information must appear on the product itself.  
The left side of the battery housing indicates the battery expiry date. Space  
is provided for the beacon owner to mark the date the beacon was placed  
into service. The beacon should be serviced 5 years from the installation  
date but no later than the battery expiry date.  
The ACR HydroFix™ HRU has an expiration date of 2 years from the date  
of installation or 4 years from the date manufactured, whichever comes  
first. Upon installing your beacon or new HRU, permanently scratch the  
new expiration date on the HRU date calendar as seen below.  
Date of Installation Example:  
Date of installation of New HRU or First  
Installation of EPIRB including new  
HRU: August 1, 2010.  
This unit will need to be replaced in  
August of 2012. Scratch off “AUG 8”  
and “2011” on the HRU date calendar  
Date of Manufacture Example:  
On the bottom of the HRU a date of  
manufacture is pin stamped: 0808.  
This unit will need to be replaced in  
August 2012. Scratch off “AUG 8” and  
“2012” on the HRU date calendar  
2.  
Mounting location  
The selection of a mounting location will vary from vessel to vessel.  
Beacons should be protected from outside influences while being readily  
accessible at all times in the event of an emergency.  
The location selected must be sufficiently rigid to support the weight of the  
total installation.  
Hazards to avoid when selecting a mounting location:  
// Vibration  
// Exposure to the elements  
// Possibility of impact from hatches, gear, or personnel  
// Harmful vapors  
// Exhaust  
// Harsh chemicals  
// Locations that can be obscured by foreign articles on a temporary or  
permanent basis.  
Y1-03-0250DRowenvl.oaBd from Www.Somanuals.com. All Manuals Search And Download.  
15  
 
CAUTION: Category I brackets must be mounted free from  
obstruction to allow the beacon to automatically float free from the vessel  
in case of sinking. The SeaShelter3can be mounted on a vertical  
surface with the beacon antenna pointing skyward or a horizontal surface  
with the beacon face up. Avoid mounting locations that subject the  
bracket to breaking waves. Avoid structures like dodgers or cabin tops  
that could trap the beacon upon deployment.  
CAUTION: Category II brackets must be mounted in a protected  
location that is easily accessible should it be necessary to abandon ship.  
The QuickDraw™ can be mounted on a vertical surface with the beacon  
antenna pointing skyward or a horizontal surface with the beacon face  
up. Avoid mounting locations that subject the bracket to breaking waves.  
Avoid mounting locations that do not provide protection from harmful UV  
rays of the sun. The bracket must be mounted facing inboard to avoid  
being lost overboard due to impacts of breaking waves, personnel or  
loose gear.  
Visually inspect the area surrounding the mounting bracket installation site  
for hidden hazards or obstacles that may have been overlooked during the  
location selection. If there is any doubt as to the ready accessibility to the  
beacon at all times or if any condition may appear to be questionable,  
conduct a complete and thorough investigation before final approval of the  
installation.  
NOTE: When selecting the beacon bracket location, be sure to consider the  
requirement for four screw holes to secure the bracket.  
CAUTION: Keep this beacon a safe distance away from all  
magnetic sources. Magnet safe distance is 4.6 ft or 1.4 m, including  
the distance from stereo speakers.  
Y1-03-0250DRowenvl.oaBd from Www.Somanuals.com. All Manuals Search And Download.  
16  
3.  
Category I bracket  
The SeaShelter3™ Category I bracket has five pre-drilled screw holes to use  
for securing the bracket to a flat surface. Remove the SeaShelter3™ lid by  
turning the spring loaded knob on the lid 1/4 turn counterclockwise and pull.  
The lid will lift away from the top of the base and disengage at the bottom of  
the base. The lid is tethered to the base to help prevent loss. Pull the  
beacon with steady pressure from the bracket. It is not necessary to remove  
the HydroFix™ Hydrostatic Release Unit (HRU) to mount the bracket using  
four of the holes. For extreme conditions a fifth hole is available when the  
HydroFix is removed and the ejector spring is deployed. The bracket can be  
held in place to mark the placement of the screw holes or you can use the  
mounting template provided. The use of #10 pan head stainless steel  
fasteners (minimum of ½” long) and ½” washers (not included) is  
recommended. Make sure that fasteners will not contact any wires or  
plumbing before drilling pilot holes.  
Y1-03-0250DRowenvl.oaBd from Www.Somanuals.com. All Manuals Search And Download.  
17  
4.  
Category II bracket  
Category II brackets are designed to hold the beacon securely in place. The  
beacon must be manually deployed. The bracket can be mounted on a  
vertical flat surface with beacon antenna up or on a horizontal flat surface  
facing skyward. This location must be easily accessible in order to manually  
deploy the beacon or to perform the required maintenance and functionality  
tests. Typical locations include near the helm station or just inside the  
companionway door.  
The QuickDraw™ Category II bracket has three pre-drilled screw holes to  
use for securing the bracket to a flat surface. Remove the beacon from the  
bracket. To do this while holding the assembly, press the “PUSH” lever to  
release the beacon from the bracket. Pull the beacon forward and down to  
remove. The bracket can be held in place to mark the holes. The use of #8  
pan head stainless steel fasteners and washers (not included) is  
recommended. Be sure to confirm that fasteners will not contact any wires  
or plumbing before drilling pilot holes.  
Push to Release  
To reinstall the beacon inside the bracket, place  
the antenna behind the top notch in the bracket.  
The yellow lanyard roll faces the bracket and rests  
in the concave part of the bracket. Snap the  
beacon into place by pushing firmly at the bottom  
of the beacon (on the ACR logo) until the snaps  
engage the bottom of the beacon.  
Top in First  
Bottom in Second  
Y1-03-0250DRowenvl.oaBd from Www.Somanuals.com. All Manuals Search And Download.  
18  
5. Installing the Optional optical GPS interface cable  
The beacon is fitted with an  
optical interface to connect with  
an external Global Positioning  
System (GPS) receiver that will  
determine the latitude and  
longitude of its position.  
The black lead wire with white  
stripes should be connected to  
the output of the external GPS  
receiver positive transmitter pin.  
The black wire should be  
connected to the negative pin.  
If you have a Category I beacon and bracket, the connector is at the end of  
the black lead wire plugs into the beacon via the bezel on the top of the  
beacon. See the location of the GPS interface in previous figures (“Anatomy  
of your beacon”, page 7 and “Top View”, page 8). It is important to seat the  
connector completely in the bezel for an operational connection.  
If you have a Category II beacon and bracket, your connector has two  
extensions on it that must be aligned with the two notches on the Category II  
beacon bezel. The connector is then gently inserted downward into place  
and turned 90° to lock the connector into the bezel.  
If the external GPS receiver is operational and the connection has been  
correctly made to the optical interface, the green LED in the optical interface  
will start flashing at activation.  
NOTE: The baud rate output for your GPS receiver NMEA 0183 should be  
4800 bps. If you are not sure if your receiver is NMEA 0183 compliant,  
check the interface settings listed in your GPS manual. To optimize your  
GPS interface feature, be sure that your GPS receiver is equipped with a  
NMEA 0183 Version 1.5 or higher with GPGGA sentence enabled.  
Consult your GPS receiver manual for the maximum cable length  
acceptable for an external GPS connection to the beacon. Also see  
Appendix A for information regarding the use and testing of your GPS  
system in conjunction with the beacon.  
Using the optical interface is not necessary for the beacon to function  
properly; it will, however, enhance the beacon’s performance.  
Y1-03-0250DRowenvl.oaBd from Www.Somanuals.com. All Manuals Search And Download.  
19  
STEP FOUR - MAINTAINING THE BEACON  
1.  
Safety DOs and DON’Ts  
On a routine basis aboard ship, DO NOT:  
// Hold or carry the beacon by its antenna  
// Mount the beacon in its bracket close to large structures or magnetic  
areas  
// Tie the lanyard to the EPIRB bracket or any other structure  
// Obscure the beacon by placing objects in front of it  
On a routine basis aboard ship, DO:  
// Mount the beacon in its bracket in an obvious location, so that all can  
see it  
// Mount the beacon in its bracket with the rolled lanyard facing inward  
(facing the bracket)  
// Follow the recommended maintenance schedule  
// Perform a beacon Self-Test monthly  
// Follow up with beacon service if Self-Test fails  
2.  
Routine beacon maintenance  
At least every ninety days, the float free mounting bracket and beacon  
should be inspected for deterioration and/or residue buildup that may affect  
the function of the beacon or automatic release. Part of the visual check  
includes checking the antenna for tightness. Clean the beacon and the  
mounting bracket to remove any residue buildups. It is recommended that  
the beacon and mounting bracket be wiped with a damp cloth.  
Carefully inspect the beacon case for any visible cracks. Cracks may admit  
moisture, which could falsely activate the beacon or otherwise cause a  
malfunction. Any cracks observed should immediately be referred to ACR  
Service for evaluation. Call ACR Electronics Technical Service +1 (954)  
981-3333.  
3.  
Battery replacement  
Battery replacement is due 5 years from date after the beacon placed into  
service, or by expiry date on the beacon whichever is first. During each  
inspection, check the time remaining until battery replacement is required.  
The battery must also be replaced if the beacon has been activated for any  
use other than the Self-Test.  
Y1-03-0250DRowenvl.oaBd from Www.Somanuals.com. All Manuals Search And Download.  
20  
 
Always refer battery replacement and any other beacon service to a factory  
authorized Service Center. Find Center near you at  
a
http://www.acrelectronics.com/brc.htm. Battery replacement includes  
servicing the beacon by replacing all o-rings, testing the water seal and the  
electrical properties and doing a full functional test on the unit.  
NOTE: There are no user serviceable items inside the beacon. Do not open  
the beacon except to disable (in case of faulty or accidental activation).  
Otherwise, always have the beacon serviced.  
WARNING: Battery contains lithium  
To avoid possible fire, explosion, leakage or burn hazard, do not open,  
recharge, disassemble or heat beacon above +70º C (+158º F) or  
incinerate.  
These products contain lithium in the battery. Various beacons may or may  
not require special shipping instructions due to the lithium batteries and  
changes in shipping regulations. Shipping of hazardous materials requires  
special handling and documentation. MSDS sheets, along with  
shipping  
information,  
can  
be  
found  
on  
our  
website  
at  
In the case of the RLB-38, the product contains small batteries that are non-  
hazardous. However, regulations can change. Be advised that it is best to  
verify the shipping requirements at the time you are preparing to ship the  
unit.  
4.  
Shore based maintenance for SOLAS vessels, (SBM) IMO  
MSC/Circ. 1039  
The Maritime Safety Committee has approved guidelines for shore-based  
maintenance of satellite beacons, for the purpose of establishing  
standardized procedures and minimum levels of service for the testing and  
maintenance of satellite beacons. The first shore based maintenance on all  
ACR EPIRBs is due at the date of the first battery replacement. Visit ACR’s  
website at www.acrelectronics.com for organizations that perform shore  
based maintenance.  
5.  
Annual testing for SOLAS vessels, IMO MSC/Circ. 1040  
SOLAS regulation IV/15.9 dictates annual testing of 406 MHz satellite  
EPIRBs. Testing should be carried out using suitable test equipment  
capable of performing the relevant measurements. All checks of electrical  
parameters should be performed in the self-test mode, if possible. These  
tests can be performed by certified ACR Battery Replacement Centers  
(BRCs). Visit ACR’s website at www.acrelectronics.com for authorized ACR  
BRCs.  
Y1-03-0250DRowenvl.oaBd from Www.Somanuals.com. All Manuals Search And Download.  
21  
6.  
Changing ownership or contact information  
As the owner of the beacon, it is your responsibility to advise the national  
authority of any change in the information on the registration form. If you are  
transferring the beacon to a new owner, you are required to inform the  
national authority. You can do this by using their online database or by  
letter, fax or telephone and informing the authority of the name and address  
of the new owner.  
The new owner of the beacon is required to provide the national authority  
with all of the information requested on the registration form. This obligation  
transfers to all subsequent owners. Registration forms for the United States  
are available from NOAA by calling (888) 212-7283 (212-SAVE) or by  
visiting the ACR website at www.acrelectronics.com. Outside of the United  
States, the new owner may contact his local authority for the necessary  
form(s).  
7.  
Lost or stolen EPIRBs  
If your EPIRB is lost or stolen, do the following immediately:  
// Report to your local authorities that the EPIRB has been lost or stolen  
// Contact NOAA at (888) 212-7283 (212-SAVE), or your national  
authority, with the following information:  
o
o
o
Police department name  
Police department phone number  
Police case number  
If your EPIRB were to be activated, the information you provided will be  
forwarded to the appropriate search and rescue authorities who will ensure  
that your EPIRB gets back to you. If someone attempts to register an EPIRB  
reported as stolen, NOAA or your national authority will notify the  
appropriate police department. Visit www.cospas-sarsat.org for more  
information.  
8.  
Servicing the SeaShelter3™ and the HydroFix™ HRU  
The SeaShelter3™ Category I bracket has two main  
pieces, the lid and the base. To open the bracket, turn the  
spring loaded knob counterclockwise 1/4 of a turn and  
pull. The lid will lift away from the top of the base and  
disengage from the detent at the bottom of the base. The  
lid is tethered to the base to help prevent loss.  
Brackets are a key part of the overall beacon system.  
They hold a beacon ready for deployment while preventing  
false alarms. Category I brackets also require replacement  
of the Hydrostatic Release Unit every two years.  
Y1-03-0250DRowenvl.oaBd from Www.Somanuals.com. All Manuals Search And Download.  
22  
NOTE: Whenever a beacon is returned for service, it  
must be accompanied by the bracket.  
To remove the expired HRU  
When opening the SeaShelter3™ lid, note that the beacon is installed with  
the lanyard face in. Pull the beacon with steady pressure from the bracket.  
Do not get beacon wet while out of bracket. The HRU has a keying feature  
that locks it to the bracket. If you view the HRU rod as the center of a clock,  
a properly installed HRU will rest at the 7 o’clock position, as shown in the  
picture above.  
WARNING: The HRU holds down an ejection spring. The spring must  
be held in place during the removal and installation of the HydroFix™ to  
prevent injury.  
Depress the top of the ejection spring. This will relieve pressure on the HRU  
and allow it to be rotated counterclockwise to the 5 o’clock position. The  
HRU is now free to be removed. Slowly relieve pressure from the ejection  
spring and allow it to deploy.  
WARNING: Discard the expired HRU. Failure to replace the entire  
assembly may cause the bracket to malfunction.  
WARNING: Be sure to use only ACR’s HydroFix™ HRU (ACR P/N  
9490) in the SeaShelter3™. Use of unauthorized replacement parts will void  
your warranty and may cause the bracket to malfunction.  
Check the date of manufacture on the new HRU. Follow the instructions that  
accompany the HydroFix™ for marking the next expiry date and for  
selecting the correct rod adapter for the SeaShelter3™.  
To install the new HRU  
Apply pressure to the ejection spring and hold it flat against the bracket.  
With your free hand place the new HRU into the key way in the 5 o’clock  
position and rotate clockwise to the 7 o’clock position. Slowly remove  
pressure from the ejection spring. The HRU should now be held in the 7  
o’clock position with the pressure on the ejection spring.  
Reinstall the beacon with lanyard face in. Beacon should fit snugly in the  
bracket with the antenna captured by the bracket. Reinstall the lid by seating  
the bottom of the lid to the detent on the base. Close the upper portion of  
the lid so the HRU rod lines up with the spring loaded knob. With gentle  
pressure, hold the lid while you turn the lock counterclockwise until it stops,  
then clockwise until it stops. This should capture the HRU and snap the lid  
into a locked position. Confirm that the lid is attached to the bottom of the  
bracket and the HRU.  
Y1-03-0250DRowenvl.oaBd from Www.Somanuals.com. All Manuals Search And Download.  
23  
CAUTION: Do not force the lid closed. If the lid does not close easily,  
check to see that the beacon is properly installed in the bracket and the  
HydroFix™ is properly seated.  
9.  
Servicing the QuickDraw™  
To remove a beacon from the Category II bracket, press the “PUSH” lever to  
release the beacon from the bracket. The beacon will now be able to  
forward and down out of the bracket.  
It is not anticipated that the QuickDrawwill require servicing other than  
cleaning or, rarely, replacement.  
NOTE: Whenever a beacon is returned for service, it must be accompanied  
by the bracket.  
10. Self-Testing the beacon  
The Satellite3 406™ beacon may be self-tested as is warranted, up to a  
maximum of sixty times in the five-year life of the battery, or once per month  
for the life of the battery. Self-Tests can be performed randomly, however,  
ACR recommends that you perform the Self-Test on a once per month  
schedule. Do not exceed sixty (60) Self-Test cycles limit in the five-year life  
of the battery, to conserve the battery for emergency use.  
The functional Self-Test is initiated by momentarily  
lifting the Activation Switch to a vertical position and  
holding it in this position for at least one second and at  
most four seconds. A beep indicates the initiation of  
the Self-Test sequence. Self-Test will check battery  
capacity and perform four functional test sequences as  
described below.  
TEST  
SUCCESS  
FAIL  
EEPROM Connect  
Lock Circuit  
Signal Strength  
Locator Light  
Summary  
Beep, Green LED  
Test Stopped, Red LED  
Test Stopped, Red LED  
Test Stopped, Red LED  
Test Stopped, Red LED  
Beep, Green LED  
Beep, Green LED  
Beep, Green LED, Strobe  
Green LED  
The last green LED indicates a successful test. If any of the individual tests  
fail during Self-Test, there will be two beeps and a red LED flash at the end  
of the Self-Test. Self-Test will discontinue at that point.  
NOTE: The “beeps” are a very high-pitched tone that some people may not  
be able to hear. You may count the green LED flashes.  
Y1-03-0250DRowenvl.oaBd from Www.Somanuals.com. All Manuals Search And Download.  
24  
APPENDIX A - USING AND TESTING THE GPS SYSTEMS  
1.  
How the external GPS interface works  
The beacon is fitted with an optical interface to connect with an external  
Global Positioning System (GPS) receiver that will determine the latitude  
and longitude of its position. This data is transmitted to the emergency  
system. When the beacon is coupled to a working external GPS receiver, it  
immediately begins downloading data. Once valid position data has been  
obtained, the beacon will attempt to update the positional data every 20  
minutes. The Satellite3 406™ will store the last valid positional data for up to  
4 hours, if it becomes unable to obtain new updated data. It will update this  
data if and only if it receives new good positional data from the external  
GPS receiver.  
2.  
Using the external GPS interface  
Once a compatible, operating GPS receiver is connected to the Satellite3  
406™, the beacon will store coordinate data for incorporation into the  
emergency message. The coordinates are transmitted to the satellite when  
the beacon is activated in an emergency. Coordinate data provides a more  
accurate location to the Search and Rescue Authority and may lead to a  
faster rescue. Since the last valid GPS position data may stay in the  
memory for up to 4 hours, the user should take care to make sure that the  
GPS position data stored is accurate. This can be accomplished by two  
methods:  
//  
connected to the beacon before activation, or…  
// By connecting a properly functioning external GPS receiver with a  
By always leaving a properly functioning external GPS receiver  
valid position fix, and allowing sufficient time to acquire valid GPS position  
data.  
3.  
Testing the external GPS interface  
Connect the optical interface plug to the beacon bezel and allow sufficient  
time for the GPS receiver to acquire valid GPS position data (usually less  
than 1 minute; but it can take up to 20 minutes). Lift the thumb switch to the  
vertical (Self-Test) position and release. Your beacon will confirm that it has  
acquired valid GPS data by flashing an extra green LED at the end of a Self-  
Test.  
4.  
Updating the external GPS position data  
When the beacon is properly connected to a functioning and compatible  
GPS receiver, GPS position data is automatically updated about every 20  
minutes while valid GPS position data is present. The operator can force the  
acquisition of new GPS position data by initiating a Self-Test with the  
beacon connected to an external GPS receiver with a valid position fix. This  
Y1-03-0250DRowenvl.oaBd from Www.Somanuals.com. All Manuals Search And Download.  
25  
 
bypasses the normal, programmed, waiting time of 20 minutes for the  
automatic update of GPS position data.  
If no valid GPS position data is available, the beacon will keep the  
previously stored GPS position data for up to 4 hours. In this case, call ACR  
Customer Service at +1 (954) 981-3333 for instructions on how to reset the  
beacon with the default message.  
A new beacon is programmed with the GPS position data set to a default. If  
the beacon should be activated, this default GPS position data indicates to  
the satellite system that the beacon has no valid GPS position stored in  
memory. Once a functioning and compatible external GPS receiver is  
properly connected to the beacon, the default data will be replaced by valid  
GPS position data, as described in the previous sections.  
5.  
LED indication of GPS fix  
When the beacon is activated and valid coordinates are acquired, the data  
is included in the digital message of the next 406 MHz transmission. The  
LED blinks green when GPS coordinates are sent.  
If a time period of 4 hours passes without the internal GPS receiver being  
able to update the last good set of navigational coordinates, the message  
transmitted by the beacon will revert back to default data. At this point the  
green LED will stop blinking and the red LED will flash. The internal GPS will  
continue to seek coordinates and when successful the green LED will flash.  
This new data will be transmitted in the next message burst and the green  
LED will continue to flash.  
6.  
Compatible GPS receivers  
External GPS interface requirements: In order to be compatible with the  
Satellite3 406™, an external GPS receiver must provide location information  
according to the following requirements:  
// NMEA 0183, Version 1.5 or higher  
// Baud rate: 4800  
// Talker device identifier: GP (GPS Receiver)  
// Sentence format: GGA (GPS Fix Data)  
For more information regarding external GPS device compatibility, please  
visit the ACR website at www.acrelectronics.com.  
Y1-03-0250DRowenvl.oaBd from Www.Somanuals.com. All Manuals Search And Download.  
26  
APPENDIX B - THE COSPAS-SARSAT SYSTEM  
1.  
General overview  
EPIRBs transmit to the satellite portion of the Cospas-Sarsat system. Cospas-Sarast  
satellites are an international system that utilizes Russian Federation and United States’  
low altitude, near-polar orbiting satellites (LEOSAR). These satellites assist in detecting  
and locating activated 406 MHz satellite beacons.  
Cospas-Sarsat satellites receive distress signals  
from EPIRBs transmitting on the frequency of  
406 MHz. The Cospas-Sarsat 406 MHz beacon  
signal consists of  
a
transmission of non-  
modulated carriers followed by a digital message  
format that provides identification data. The 406  
MHz system uses satellite-borne equipment to  
measure and store the Doppler-shifted frequency  
along with the beacon’s digital data message and  
time of measurement. This information is  
transmitted in real time to an earth station called  
the Local User Terminal (LUT), which may be  
within the view of the satellite, as well as being stored for later transmission to other  
LUTs.  
The LUT processes the Doppler-shifted signal from the LEOSAR and determines the  
location of the beacon, then the LUT relays the position of the distress to a Mission  
Control Center (MCC) where the distress alert and location information is immediately  
forwarded to an appropriate Rescue Coordination Center (RCC). The RCC dispatches  
Search and Rescue (SAR) forces.  
The addition of the GEOSAR satellite system greatly improves the reaction time for a  
SAR event. This satellite system has no Doppler capabilities at 406 MHz, but will relay the  
distress alert to any of the LUT stations. When there is GPS data included in the distress  
message, SAR authorities instantly know your location to within 110 yards (100 m). This  
speeds up the reaction time by not having to wait for one of the LEOSAR satellite to pass  
overhead. Because most of the search and rescue forces presently are not equipped to  
home in on the 406 MHz Satellite beacons signal, homing must be accomplished at 121.5  
MHz.  
Once the 406 MHz signal is relayed through the LEOSAR and/or GEOSAR network, SAR  
forces determine who is closest, and then proceed to the beacon using the 121.5 MHz  
homing frequency.  
2.  
Global Positioning System (GPS)  
The GPS system is a satellite group that enables a GPS receiver to  
determine its exact position to within 30 m (100 ft.) anywhere on  
earth. With a minimum of 24 GPS satellites orbiting the earth at an  
altitude of approximately 11,000 miles they provide users with  
accurate information on position, velocity, and time anywhere in the  
world and in all weather conditions. The GlobalFix™ iPRO stores  
adds this data to its distress transmission, allowing search and  
rescue forces to narrow the search to a very small area, thus  
minimizing the resources required, and dramatically increasing  
the effectiveness of the overall operation.  
Y1-03-0250DRowenvl.oaBd from Www.Somanuals.com. All Manuals Search And Download.  
27  
 
APPENDIX C - TECHNICAL SPECIFICATIONS  
GENERAL/ ENVIRONMENTAL  
Beacon size (without antenna)  
Beacon weight  
Beacon material  
Color  
17.7 H X 10.67 W X 9.09 D cm (6.97 X 4.2 X 3.58 in)  
581 g (20.49 oz)  
High impact UV resistant polymer  
ACR-Treuse™ (high visibility yellow)  
Tested to 10 min @10 m (33 ft), exceeds RTCM  
standard  
Waterproof  
Buoyant  
Yes  
Deployment  
Category I: Automatic hydrostatic release  
Category II: Manual  
BATTERY  
Operational life  
48 hours minimum @-20º C (-4º F) (Class 2)  
Battery type and  
replacement interval  
LiMnO2  
5 years from date beacon placed in service,  
or after use in an emergency not to exceed battery  
expiry  
Operating temperatures  
Storage temperatures  
-20º C to +55º C (-4º F to +131º F) (Class 2)  
-30º C to +70º C (-22º F to +158º F) (Class 2)  
406 MHz TRANSMITTER  
406.037 MHz  
Frequency  
Power output  
5 W  
Digital message format  
Standard location protocol (for the USA; Beacon can  
be reprogrammed at a service center to other coded  
formats, and to national location protocol)  
121.5 MHz TRANSMITTER  
121.5 MHz  
Frequency  
Power output  
Modulation type  
25 mW PEP  
AM (3K20A3X)  
LED STROBE  
Light color  
Output power  
Flash rate  
Range  
White  
1 cd (effective candela)  
20-30/ min  
360º visibility  
GENERAL  
Accessories  
SeaShelter3™ Category I Mounting bracket, ACR  
P/N 9501  
QuickDraw™ Category II Mounting bracket, ACR  
P/N 9507  
HydroFix™ universal hydrostatic release (HRU)  
kit, ACR P/N 9490  
Optional External GPS Optical Interface Cable for  
Category I Mounting bracket, ACR P/N 9388.1  
Optional External GPS Optical Interface Cable for  
Category II Mounting bracket, ACR P/N 9388  
FCC ID #B66ACR-RLB36  
COSPAS-SARSAT certificate #189  
Approvals  
NOTE: For complete information regarding beacon type approvals, please visit ACR’s  
Y1-03-0250DRowenvl.oaBd from Www.Somanuals.com. All Manuals Search And Download.  
28  
 
APPENDIX D - WARRANTY, USEFUL LIFE POLICY, NOTICES  
1.  
Limited Warranty  
This product is warranted against factory defects in material and workmanship for a  
period of 1 (one) year* from date of purchase or receipt as a gift. During the warranty  
period ACR Electronics, Inc. will repair or, at its option, replace the unit at no cost to  
you for labor, materials and return transportation from ACR. For further assistance,  
please contact our Technical Service Department at ACR Electronics, Inc., 5757  
Ravenswood  
Road,  
Fort  
Lauderdale,  
FL  
33312-6645.  
Email:  
[email protected], Fax: +1 (954) 983-5087, Telephone: +1 (954) 981-  
3333.  
This warranty does not apply if the product has been damaged by accident or  
misuse, or as a result of service or modification performed by an unauthorized  
factory. Except as otherwise expressly stated in the previous paragraph, THE  
COMPANY MAKES NO REPRESENTATION OR WARRANTY OF ANY KIND,  
EXPRESS OR IMPLIED, AS TO MERCHANTABILITY, FITNESS FOR  
A
PARTICULAR PURPOSE, OR ANY OTHER MATTER WITH RESPECT TO THIS  
PRODUCT. The Company shall not be liable for consequential or special damages.  
To place the warranty in effect, register online at www.acrelectronics.com or return  
the attached card within 10 days.  
*Five years for the following products: EPIRB, PLB, S-VDR, SSAS.  
2.  
Useful Life Policy  
The typical service life of a properly maintained Product is limited to 12 years from  
date of manufacture. Products that are 12 years and 1 month or older from date of  
manufacture will not be serviced by ACR or our Battery Replacement Centers. A  
Product that is 12 or less years old from date of manufacture will be serviced as long  
as the unit appears fit to be placed back into its final operational cycle. Service  
includes the replacement of those items that must be replaced at service intervals  
and the verification that the device appears to be in good mechanical and electrical  
working condition by an ACR authorized service technician.  
3.  
Notices  
ACR Electronics diligently works to provide a high quality Product Support Manual,  
however, despite best efforts, information is subject to change without notice, and  
omissions and inaccuracies are possible. ACR cannot accept liability for manual  
contents. To ensure that you have the most recent version of the Product Support  
Manual, please visit the ACR website at www.acrelectronics.com.  
©2009 by ACR Electronics, Inc., part of Cobham plc. All rights reserved.  
Reproduction in whole or in part is permitted only with permission of ACR  
Electronics, Inc.  
Ongoing product improvements may change product specifications without notice.  
Trademarks or registered trademarks are the property of their respective owners.  
Y1-03-0250DRowenvl.oaBd from Www.Somanuals.com. All Manuals Search And Download.  
29  
 
EC DECLARATION OF CONFORMITY  
ACR Electronics hereby declares that the following product is in conformity with Council Directive  
96/98/EC of 20 December 1996 on Marine Equipment (MED) last amended by Commission Directive  
2009/26/EC of 6 April 2009, and has been type examined as described in this Declaration. In  
accordance with the Directive, the product will be marked with the MED Mark of Conformity as follows:  
0735  
yy  
yy= Last two digits of theyear inwhichthemarkis affixed  
Product:  
406 MHz (COSPAS-SARSAT) Emergency Position-Indicating Radio Beacon (EPIRB)  
MED Item A.1/5.6  
Trade Name: Satellite3 406TM  
Model: RLB-38  
Notified Body:  
Bundesamt für Seeschifffahrt und Hydrographie (BSH), Notified Body No. 0735  
Bernhard-Nocht-Str. 78, 20359 Hamburg, Germany  
EC Type Examination (Module B) Certificate No.:BSH/4612/5061677/10  
EC Quality System (Module D) Certificate No.: BSH/4613/05102/1251/09  
Regulations and  
Standards:  
IMO Resolution A.662(16)  
IMO Resolution A.694(17)  
IMO Resolution A.696(17)  
IMO Resolution A.810(19)  
IMO MSC/Circ.862  
ITU-R M.633-2 (05/00)  
ITU-R M.690-1 (10/95)  
C/S T.001 (Nov. 2007)  
C/S T.007 (Nov. 2007)  
IEC 61097-2, Ed. 3.0, 2008-01  
IEC 60945, 4th Ed., 2002-08, incl. Corr.1, 2008  
ETSI EN 300 066 V1.3.1 (2001-01)  
Manufacturer:  
ACR Electronics Inc.  
5757 Ravenswood Road  
Fort Lauderdale, FL 33312  
USA  
European  
Representative: (European Office)  
ACR Electronics Inc.  
1 Rose Cottages, Pitmore Lane,  
Sway, Lymington, Hampshire SO41 6BX UK  
Signed on behalf of ACR Electronics Inc.  
Signed:  
________________________________________  
Name:  
Title:  
Kerry Greer  
Executive Director - Research & Development  
Date:  
May 3, 2010  
Document RLB-38-002  
This Declaration complies withISO/IEC 17050-1:2004  
ACR Electronics, Inc. is registered by UL to ISO 9001:2000  
Y1-03-0250DRowenvl.oaBd from Www.Somanuals.com. All Manuals Search And Download.  
30  

ACR Electronics Marine GPS System RLB 40 User Manual
Advantech Laptop PPC S123 User Manual
Air King Ventilation Hood AK100FL User Manual
ALK Technologies GPS Receiver Pocket PC 6 Bluetooth User Manual
Altec Lansing Speaker IM4 User Manual
Alto Shaam Food Warmer TY2 72 SERIES User Manual
AMD Computer Hardware GA K8N51GMF 9 User Manual
American Dryer Clothes Dryer AD 120ES User Manual
Audiovox Car Stereo System AVD400TA User Manual
Avenview TV Cables C MDP HDMI User Manual