3D Connexion Two Way Radio CA 100Plus User Manual

CRT COLOR ANALYZER  
CRT  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CRT COLOR ANALYZER  
CA-100Plus  
Application  
Chromaticity  
Adjustment, Inspection  
White-balance  
Adjustment, Inspection  
Cut-off  
Adjustment, Inspection  
Select the probe among the following four types.  
Measuring Probe (Cable length: 2 m)  
Measuring Probe (Cable length: 5 m)  
High luminance Measuring Probe (Cable length: 2 m)  
High luminance Measuring Probe (Cable length: 5 m)  
Up to five probes can be connected to a single main body. Regular measuring  
probes and high luminance measuring probes can be connected simultaneously to a  
single main body.  
(To connect multiple probes, the optional four-point extension board (CA-B04) is  
necessary.)  
The luminance and chromaticity of display can be  
measured as fast as 20 times per second (maximum),  
reducing the time for automatic adjustment.  
FASTER  
Accuracy of 0.002 for White, 0.004 for R,G,B  
(Chromaticity)  
ACCURATE  
LOW LUMINANCE  
Precise measurement can be obtained at low luminance  
of 0.05 cd/m2 and reducing the cycle time.  
Range of luminance for chromaticity measurement: 0.05 to 1000 cd/m2 (Measuring probe)  
0.05 to 2000 cd/m2 (High luminance measuring probe)  
Compatible with CA-100.  
Compact nearly A4 size (width and depth).  
EASY TO USE  
Sample software is bundled; you can control easily by PC.  
Expandable up to 5 sensing probes.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Diagram  
Dimensions  
(Units : mm)  
PC (Commercially available)  
PC-AT compatible  
4-Probe Expansion Board  
CA-B04  
Multi-Probe  
φ60  
340  
(Optional)  
φ
45  
Measuring Probe (2 m) CA-P02  
Measuring Probe (5 m) CA-P05  
High luminance Measuring Probe (2 m) CA-PH02  
High luminance Measuring Probe (5 m) CA-PH05  
(Optional)  
30.2  
PC Software for Color Analyzer  
CA-SDK (Standard)  
φ44  
CA-100Plus  
Measuring Probe Holder  
CA-A11 (Standard)  
Measuring Probe (2 m) CA-P02  
Measuring Probe (5 m) CA-P05  
High luminance Measuring Probe (2 m) CA-PH02  
High luminance Measuring Probe (5 m) CA-PH05  
AC Power Cord (Standard)  
Specifications  
CA-100Plus(Measuring Probe 2 m or 5 m)  
Detector : Silicon photo cell  
CA-100Plus(High luminance Measuring Probe 2 m or 5 m)  
0.01 to 2000 cd/m2  
Receptor  
Display range  
Luminance  
0.01 to 1000 cd/m2  
Chromaticity  
Displayed in 4 or 3-digit value (Can be chosen)  
Luminance  
Measurement range  
Accuracy (for white)*1  
Repeatability *1  
0.05 to 1000 cd/m2  
0.05 to 2000 cd/m2  
±2 %±1 digit of reading (temperature : 23°C±2°C, relative humidity : (40±10)%)  
0.05 to 1000 cd/m2  
0.2 %+1 digit (2 σ)  
0.05 to 2000 cd/m2  
0.2 %+1 digit (2 σ)  
Chromaticity  
Measurement range  
Accuracy *1  
(temperature : 23°C±2°C,  
relative humidity : (40±10)%)  
0.05 to 1000 cd/m2  
0.05 to 2000 cd/m2  
0.05 to 0.19 cd/m2 ±0.006 (for white)  
0.20 to 0.49 cd/m2 ±0.004 (for white)  
0.50 to 1000 cd/m2±0.003 (for white)  
0.05 to 0.09 cd/m2 ±0.008 (for white)  
0.10 to 0.39 cd/m2 ±0.006 (for white)  
0.40 to 0.99 cd/m2 ±0.004 (for white)  
1.00 to 2000 cd/m2±0.003 (for white)  
40.00 cd/m2  
±0.002 (for white), ±0.004 (for monochrome)*2  
40.00 cd/m2  
±0.002 (for white), ±0.004 (for monochrome)*2  
0.05 to 0.19 cd/m2 0.006 (2 σ)  
0.20 to 0.49 cd/m2 0.002 (2 σ)  
0.50 to 1000 cd/m2 0.001 (2 σ)  
0.05 to 0.09 cd/m2 0.009 (2 σ)  
0.10 to 0.39 cd/m2 0.006 (2 σ)  
0.40 to 0.99 cd/m2 0.002 (2 σ)  
1.00 to 2000 cd/m2 0.001 (2 σ)  
Repeatability *1  
Measurement speed xyLv  
*3  
0.05 to 0.99 cd/m2  
5 measurements/sec. (4.5 measurements / sec.)*4  
0.05 to 1.99 cd/m2  
5 measurements/sec. (4.5 measurements / sec.)*4  
1.00 to 1000 cd/m2 20 measurements/sec. (17 measurements / sec.)*4  
2.00 to 2000 cd/m2 20 measurements/sec. (17 measurements / sec.)*4  
Display  
Digital  
Analog  
xyLv, TuvLv, RGB, XYZ, u'v'Lv  
x, y, Lv, R/G, B/G, G, R, B/R, G/R  
SYNC mode  
NTSC, PAL, EXT, UNIV, INT  
Object under measurement  
Memory channel  
Vertical syncronizing frequency : 40 to 200 Hz  
100 channels  
Analyzer function  
Standard function  
Interface  
USB (1.1 conformity) , RS-232C (38,400 bps or below)  
Max. 5 points (Use 4-Probe Expansion Board CA-B04)  
Temperature : 10 to 28°C; relative humidity 70 % or less with no condensation  
Luminance change : ±2 % ±1 digit of reading for white  
Multi-point Measurement  
Operating temperature/humidity range  
Chromaticity change : ±0.002 for white, ±0.006 for monochrome  
from reading of Konica Minolta's standard CRT*1, 40.00 cd/m2, with 23°C 40 %  
0 to 28°C : relative humidity 70 % or less with no condensation  
28 to 40°C : relative humidity 40 % or less with no condensation  
Storage temperature/humidity range  
Input voltage range  
~
100-240 V , 50-60 Hz 50 VA  
Size  
Weight  
Mainbody, Probe  
Mainbody, Probe  
340 × 127 × 216 mm (W × H × D), φ45 × 142 mm  
3.58 kg, 285 g  
*1 The chromaticity and luminance are measured under Konica Minolta’s condition (standard CRT (6500 K) is used).  
*2 The luminance for monochrome is measured when the reading of luminance for white is 40.00 cd/m2.  
*3 Measuring probe connected to probe connector P1 only,used USB (used RS-232C Baud rate: 38400 bps  
*4 At the CA-200 mode  
)
Select the probe among the four types.  
Specifications are subject to change without notice.  
SAFETY PRECAUTIONS  
For correct use and for your safety, be sure to read  
the instruction manual before using the instrument.  
Always connect the instrument to the  
specified power supply voltage.  
Improper connection may cause a fire  
or electric shock.  
Certificate No :YKA 0937154  
Registration Date : March 3, 1995  
Certificate No : JQA-E-80027  
Registration Date : March 12, 1997  
9
©2003 KONICA MINOLTA SENSING, INC.  
9242-4885-12 AGMEPK  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Printed in Japan  

3M Tablet Accessory 800ab User Manual
Aastra Telecom GPS Receiver 5216 User Manual
Acu Rite Weather Radio 01098CDI User Manual
ADC Network Card CRA C User Manual
Agri Fab Yard Vacuum 190 217D 100 User Manual
AO Smith Water Heater BTH 120 250 User Manual
Avon Appliances Cookware CSIE 503 User Manual
Axor Indoor Furnishings 40352000 User Manual
Axor Plumbing Product 16505001 User Manual
Tripp Lite Surge Protector Protect It User Manual