CRT COLOR ANALYZER
CRT
Download from Www.Somanuals.com. All Manuals Search And Download.
CRT COLOR ANALYZER
CA-100Plus
Application
Chromaticity
Adjustment, Inspection
White-balance
Adjustment, Inspection
Cut-off
Adjustment, Inspection
Select the probe among the following four types.
ꢁMeasuring Probe (Cable length: 2 m)
ꢁMeasuring Probe (Cable length: 5 m)
ꢁHigh luminance Measuring Probe (Cable length: 2 m)
ꢁHigh luminance Measuring Probe (Cable length: 5 m)
∗Up to five probes can be connected to a single main body. Regular measuring
probes and high luminance measuring probes can be connected simultaneously to a
single main body.
(To connect multiple probes, the optional four-point extension board (CA-B04) is
necessary.)
ꢀ
The luminance and chromaticity of display can be
measured as fast as 20 times per second (maximum),
reducing the time for automatic adjustment.
FASTER
ꢀ
Accuracy of 0.002 for White, 0.004 for R,G,B
(Chromaticity)
ACCURATE
LOW LUMINANCE
ꢀ
Precise measurement can be obtained at low luminance
of 0.05 cd/m2 and reducing the cycle time.
Range of luminance for chromaticity measurement: 0.05 to 1000 cd/m2 (Measuring probe)
0.05 to 2000 cd/m2 (High luminance measuring probe)
ꢀ
Compatible with CA-100.
ꢀ
Compact nearly A4 size (width and depth).
EASY TO USE
ꢀ
Sample software is bundled; you can control easily by PC.
ꢀ
Expandable up to 5 sensing probes.
Download from Www.Somanuals.com. All Manuals Search And Download.
System Diagram
Dimensions
(Units : mm)
PC (Commercially available)
PC-AT compatible
4-Probe Expansion Board
CA-B04
Multi-Probe
φ60
340
(Optional)
φ
45
Measuring Probe (2 m) CA-P02
Measuring Probe (5 m) CA-P05
High luminance Measuring Probe (2 m) CA-PH02
High luminance Measuring Probe (5 m) CA-PH05
(Optional)
30.2
PC Software for Color Analyzer
CA-SDK (Standard)
φ44
CA-100Plus
Measuring Probe Holder
CA-A11 (Standard)
Measuring Probe (2 m) CA-P02
Measuring Probe (5 m) CA-P05
High luminance Measuring Probe (2 m) CA-PH02
High luminance Measuring Probe (5 m) CA-PH05
AC Power Cord (Standard)
Specifications
CA-100Plus(Measuring Probe 2 m or 5 m)
Detector : Silicon photo cell
CA-100Plus(High luminance Measuring Probe 2 m or 5 m)
0.01 to 2000 cd/m2
Receptor
Display range
Luminance
0.01 to 1000 cd/m2
Chromaticity
Displayed in 4 or 3-digit value (Can be chosen)
Luminance
Measurement range
Accuracy (for white)*1
Repeatability *1
0.05 to 1000 cd/m2
0.05 to 2000 cd/m2
±2 %±1 digit of reading (temperature : 23°C±2°C, relative humidity : (40±10)%)
0.05 to 1000 cd/m2
0.2 %+1 digit (2 σ)
0.05 to 2000 cd/m2
0.2 %+1 digit (2 σ)
Chromaticity
Measurement range
Accuracy *1
(temperature : 23°C±2°C,
relative humidity : (40±10)%)
0.05 to 1000 cd/m2
0.05 to 2000 cd/m2
0.05 to 0.19 cd/m2 ±0.006 (for white)
0.20 to 0.49 cd/m2 ±0.004 (for white)
0.50 to 1000 cd/m2±0.003 (for white)
0.05 to 0.09 cd/m2 ±0.008 (for white)
0.10 to 0.39 cd/m2 ±0.006 (for white)
0.40 to 0.99 cd/m2 ±0.004 (for white)
1.00 to 2000 cd/m2±0.003 (for white)
40.00 cd/m2
±0.002 (for white), ±0.004 (for monochrome)*2
40.00 cd/m2
±0.002 (for white), ±0.004 (for monochrome)*2
0.05 to 0.19 cd/m2 0.006 (2 σ)
0.20 to 0.49 cd/m2 0.002 (2 σ)
0.50 to 1000 cd/m2 0.001 (2 σ)
0.05 to 0.09 cd/m2 0.009 (2 σ)
0.10 to 0.39 cd/m2 0.006 (2 σ)
0.40 to 0.99 cd/m2 0.002 (2 σ)
1.00 to 2000 cd/m2 0.001 (2 σ)
Repeatability *1
Measurement speed xyLv
*3
0.05 to 0.99 cd/m2
5 measurements/sec. (4.5 measurements / sec.)*4
0.05 to 1.99 cd/m2
5 measurements/sec. (4.5 measurements / sec.)*4
1.00 to 1000 cd/m2 20 measurements/sec. (17 measurements / sec.)*4
2.00 to 2000 cd/m2 20 measurements/sec. (17 measurements / sec.)*4
Display
Digital
Analog
xyLv, T∆uvLv, RGB, XYZ, u'v'Lv
∆x, ∆y, ∆Lv, R/G, B/G, ∆G, ∆R, B/R, G/R
SYNC mode
NTSC, PAL, EXT, UNIV, INT
Object under measurement
Memory channel
Vertical syncronizing frequency : 40 to 200 Hz
100 channels
Analyzer function
Standard function
Interface
USB (1.1 conformity) , RS-232C (38,400 bps or below)
Max. 5 points (Use 4-Probe Expansion Board CA-B04)
Temperature : 10 to 28°C; relative humidity 70 % or less with no condensation
Luminance change : ±2 % ±1 digit of reading for white
Multi-point Measurement
Operating temperature/humidity range
Chromaticity change : ±0.002 for white, ±0.006 for monochrome
from reading of Konica Minolta's standard CRT*1, 40.00 cd/m2, with 23°C 40 %
0 to 28°C : relative humidity 70 % or less with no condensation
28 to 40°C : relative humidity 40 % or less with no condensation
Storage temperature/humidity range
Input voltage range
~
100-240 V , 50-60 Hz 50 VA
Size
Weight
Mainbody, Probe
Mainbody, Probe
340 × 127 × 216 mm (W × H × D), φ45 × 142 mm
3.58 kg, 285 g
*1 The chromaticity and luminance are measured under Konica Minolta’s condition (standard CRT (6500 K) is used).
*2 The luminance for monochrome is measured when the reading of luminance for white is 40.00 cd/m2.
*3 Measuring probe connected to probe connector P1 only,used USB (used RS-232C Baud rate: 38400 bps
*4 At the CA-200 mode
)
� Select the probe among the four types.
� Specifications are subject to change without notice.
SAFETY PRECAUTIONS
For correct use and for your safety, be sure to read
the instruction manual before using the instrument.
Always connect the instrument to the
specified power supply voltage.
Improper connection may cause a fire
or electric shock.
Certificate No :YKA 0937154
Registration Date : March 3, 1995
Certificate No : JQA-E-80027
Registration Date : March 12, 1997
9
©2003 KONICA MINOLTA SENSING, INC.
9242-4885-12 AGMEPK
Download from Www.Somanuals.com. All Manuals Search And Download.
Printed in Japan
|